TY - CONF A1 - Pfeifer, Jens T1 - Application of glow discharge mass spectrometry for the analysis of high purity magnesium using pressed powder samples with different doping types T2 - 2nd International Glow Discharge Spectroscopy Symposium CY - Prague, Czech Republic DA - 2014-04-06 PY - 2014 AN - OPUS4-31492 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pfeifer, Jens T1 - RSFs for nickel matrix using doped pressed powder samples as needed for fast flow glow discharge mass spectrometry (GD-MS) N2 - Direct current (DC) fast flow glow discharge mass spectrometry is an important and versatile tool for multielemental trace analysis of conductive solid materials down to the µg/kg level. Special benefits are minimum demands on sample preparation, avoiding losses and contamination, and only short analysis time. For fast flow GD sources, the quantification strategy based on relative standard sensitivity factors (Standard RSFs) which are independent of matrix is not sufficiently satisfying regarding accuracy for each matrix and element [1]. Therefore matrix-matched calibration samples (MMCS) are required to achieve reliable quantification. In fact, the list of existing certified reference materials (CRM) appropri-ate for calibration in trace analysis is rather short. Convenient synthesis of homogeneous MMCS, as e.g. easily obtained in liquid sampling spectrometry, can facilitate the application of fast flow GD-MS for quantification of impurities in a variety of matrices. Pressing of metal powders for the preparation of MMCS for GD-MS was suggested earlier [2], the method was further modified by use of analyte solutions for doping of rather pure metal powders such as Cu and Zn [3], but has not yet been applied Ni matrix. In the present work we describe the determination of matrix-dependent relative sensitivity factors (RSFs) for Mg, Al, Cr, Mn, Fe, Co, Cu, Zn, Ag, Cd, Tl, Pb and Bi in pure Ni by using the liquid doping approach for the preparation of synthetic pressed Ni-powder samples. A four point-calibration was used applying the fast flow glow discharge mass spectrometer, Element GD (Thermo Fisher). The determined RSF were verified against suitable CRM and compared with the standard RSF given by the supplier of the instrument. The obtained results demonstrate a satisfying Agreement with the certified values of the CRM and a significant improvement for the quantification of most of the determined elements in comparison with standard RSF. T2 - International glow discharge spectroscopy symposium CY - Liverpool, UK DA - 18.04.2016 KW - GD-MS KW - Glow discharge KW - Nickel RSF KW - Calibration KW - Quantification PY - 2016 AN - OPUS4-35818 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pfeifer, Jens T1 - Application of Plasmasource Spectrometry for the characterization of pure zinc matrices T2 - European Winter Conference on Plasma Spectrochemistry CY - Münster, Germany DA - 2015-02-22 PY - 2015 AN - OPUS4-32568 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gonzales-Gago, C. A1 - Smid, P. A1 - Hofmann, T. A1 - Venzago, C. A1 - Hoffmann, V. A1 - Gruner, W. A1 - Pfeifer, Jens A1 - Richter, Silke A1 - Kipphardt, Heinrich T1 - Investigations of matrix independent calibration approaches in fast flow glow discharge mass spectrometry N2 - The performance of glow discharge mass spectrometry (GD-MS) is investigated for the accurate quantification of metallic impurities and oxygen in solid samples using the fast flow source GD-MS instrument ELEMENT GD. Different quantification approaches based on relative and absolute sensitivity factors are evaluated for the determination of metallic impurities using three sample matrixes (Al, Cu and Zn). The effect of the discharge conditions (voltage, current, discharge gas pressure/flow) on the sensitivity is investigated and the parameters are optimized to favour matrix independent calibrations. Improved standard relative sensitivity factors (StdRSFs) are calculated under optimal conditions based on multi-matrix calibrations. The sputtering rate corrected calibration is also presented as a multi-matrix calibration approach. The capabilities of GD-MS for oxygen determination are also investigated using a set of new conductive samples containing oxygen with mass fractions in the percent range in three different matrices (Al, Mg and Cu) produced by a sintering process. Poor limits of detection (in the order of g/kg) were obtained as consequence of the reduced sensitivity of oxygen in GD-MS and high oxygen background signal intensity as well as its variations. The absolute sensitivity procedure is shown as a matrix-independent approach, which provides quantitative values consistent with those obtained by carrier gas hot extraction (CGHE). KW - Fast flow GD KW - GDMS KW - Calibration KW - Matrix independent calibration PY - 2019 DO - https://doi.org/10.1039/c9ja00023b SN - 1364-5544 SN - 0267-9477 VL - 34 IS - 6 SP - 1109 EP - 1125 PB - Royal Society of Chemistry CY - London AN - OPUS4-47842 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Pisonero, J. A1 - Fandino, J. A1 - Nordlien, J. H A1 - Richter, Silke A1 - Pfeifer, Jens A1 - Quarles, C. D. A1 - Gonzalez, J. A1 - Jakubowski, Norbert A1 - Bordel, N. T1 - Improving the analytical performance of pulsed-GD-SFMS for multi-elemental depth profile analysis of heat-treated Zn coatings on extruded aluminium N2 - The formation of diffusion layers on Zn layers deposited on Al substrates is mainly used to prevent corrosion effects. Evaluation of the influence exerted by different coating methodologies and heat treatments on the formation of these diffusion layers is of great interest for the aluminium industry. Particularly, multi-elemental in-depth distributions of major, minor and trace elements in Zn-coatings is highly demanded before and after heat treatments. A fast characterization of these materials require a direct solid analytical technique able to provide high sensitivity and high depth resolution. For this purpose, an improved analytical method based on the use of pulsed glow discharge sector field mass spectrometry (pulsed-GD-SFMS) is investigated. Glow discharge operating parameters (e.g. pulse duration, pulse frequency), glow discharge source design (e.g. flow tube lengths), and SFMS mass spectra acquisition conditions (e.g. integration time) are evaluated to achieve low sputtering rates, high mass spectra acquisition rates and improved depth resolution. At the optimize conditions Zn coatings deposited by arc-spray and electrodeposition are analysed before and after heat treatments to evaluate the diffusion of different key elements. Moreover, results are validated using femtosecond laser ablation (fs-LA)-ICP-MS, which provides additional information about the heterogeneous distribution of some elements in the Zn coatings. KW - GDMS KW - Pulsed-GD-SFMS KW - Depht profiling KW - Zn KW - Aluminium PY - 2019 DO - https://doi.org/10.1039/c9ja00189a VL - 34 IS - 11 SP - 2252 EP - 2260 PB - Royal Society of Chemistry CY - London AN - OPUS4-49451 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -