TY - JOUR A1 - Carl, Peter A1 - Schneider, Rudolf T1 - Optimization and evaluation of a hapten microarray using chemometric methods N2 - The demands for the assessment of water quality are increasing steadily, making it necessary to routinely monitor multiple contaminants in water samples. For this application a hapten microarray was developed. In order to reach the required low detection limits a design of experiments (DoE) approach was used to optimize the assay performance. Here we show that a Box-Behnken design plan is an adequate choice for the straightforward exploration of hapten microarray assay parameters. For both read-out systems studied (fluorophore-labelled detection antibodies or enzymatic signal development followed by reflectometric scan, respectively), it was possible to significantly extend the measurement ranges. Furthermore, it could be shown that multivariate data analysis, here partial least squares regression (PLS), can improve the prediction accuracy of 'unknown' samples when used as calibration model, compared to classical, univariate data evaluation methods. KW - Koffein KW - Caffeine KW - Proteine microarray KW - Design of experiments KW - Multivariate data analysis KW - Partial least squares regression KW - Small molecule detection KW - Microarray KW - Immunoarray KW - Immunoassay KW - ELISA KW - Chemometrie KW - Chemometrics PY - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-344672 SN - 1877-7058 VL - 120 SP - 501 EP - 506 PB - Elsevier Ltd. CY - Amsterdam AN - OPUS4-34467 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Carl, Peter A1 - Ramos, InĂªs I. A1 - Segundo, Marcela A. A1 - Schneider, Rudolf T1 - Antibody conjugation to carboxyl-modified microspheres through N-hydroxysuccinimide chemistry for automated immunoassay applications: A general procedure N2 - Immunochemical techniques are the workhorse for sample enrichment and detection of a large variety of analytes. In contrast to classical microtiter plate-based assays, microparticles are a next generation solid support, as they promote automation of immunoassays using flow-based techniques. Antibody immobilization is a crucial step, as these reagentsmare expensive, and inefficient coupling can result in low sensitivities. This paper proposes a general procedure for efficient immobilization of antibodies onto TentaGel particles, via Nhydroxysuccinimide chemistry. The goal was the preparation of solid supports with optimum immunorecognition, while increasing the sustainability of the process. The influence of buffer composition, activation and coupling time, as well as the amount of antibody on the immobilization efficiency was investigated, resorting to fluorophore-labeled proteins and fluorescence imaging. Buffer pH and activation time are the most important parameters for efficient coupling. It is demonstrated, that the hydrolysis of N-hydroxysuccinimide esters occurs at similar rates as in solution, limiting the utilizable time for coupling. Finally, applicability of the generated material for automated affinity extraction is demonstrated on the mesofluidic platform lab-on-valve. KW - Mesofluidics KW - Bead injections KW - ELISA KW - Carbamazepine KW - Biomarkers PY - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-483919 SN - 1932-6203 VL - 14 IS - 6 SP - e0218686, 1 EP - 18 PB - Public Library of Science CY - San Francisco, California, USA AN - OPUS4-48391 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -