TY - CONF A1 - Panne, Ulrich T1 - Analytical chemistry in materials research T2 - CCQM-Meeting CY - Paris, France DA - 2007-04-17 PY - 2007 AN - OPUS4-16461 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kneipp, Janina A1 - Li, X. A1 - Sherwood, M. A1 - Panne, Ulrich A1 - Kneipp, H. A1 - Stockman, M.I. A1 - Kneipp, K. T1 - Gold Nanolenses Generated by Laser Ablation-Efficient Enhancing Structure for Surface Enhanced Raman Scattering Analytics and Sensing N2 - Nanoaggregates formed by metal spheres of different radii and interparticle distances represent finite, deterministic, self-similar systems that efficiently concentrate optical fields and act as “nanolenses”. Here we verify experimentally the theoretical concept of nanolenses and explore their potential as enhancing nanostructures in surface enhanced Raman scattering (SERS). Self-similar structures formed by gold nanospheres of different sizes are generated by laser ablation from solid gold into water. These nanolenses exhibit SERS enhancement factors on the order of 109. The “chemically clean” preparation process provides several advantages over chemically prepared nanoaggregates and makes the stable and biocompatible gold nanolenses potent enhancing structures for various analytical and sensing applications. KW - SERS KW - Ablation KW - Gold-Nanopartikel PY - 2008 DO - https://doi.org/10.1021/ac8002215 SN - 0003-2700 SN - 1520-6882 VL - 80 IS - 11 SP - 4247 EP - 4251 PB - American Chemical Society CY - Washington, DC AN - OPUS4-18231 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Zientek, Nicolai A1 - Meyer, Klas A1 - Panne, Ulrich A1 - Kraume, M. A1 - Maiwald, Michael T1 - Untersuchung der Auflösungskinetik von pharmazeutischen Cokristallen mittels Onlilne-NMR-Spektroskopie N2 - Bei der Entwicklung pharmazeutischer Wirkstoffe werfen Substanzen mit einer geringen Löslichkeit, Auflösungsrate und damit einhergehend schlechten Bioverfügbarkeit immer größere Probleme auf. Diese Eigenschaften und nicht etwa toxikologische Eigenschaften oder schlechte Wirksamkeit sorgen dafür, dass es weniger als 1 % aller Wirkstoffe bis in die Markteinführung schaffen. Eine Reihe von Ansätzen zur Verbesserung der schlechten Wasserlöslichkeit konnten bereits etabliert werden. Hierunter zählen die gezielte Salzbildung bzw. Salzscreening, Solubilisierung mit Cosolventien oder die Nutzung von Polymeren als mögliche Transportwege. Eine weitere Möglichkeit bietet die Bildung verschiedener polymorpher Formen, sowohl der Einzelkomponente als auch von den verschiedenen Mehrkomponentenverbindungen. T2 - 7. Interdisziplinäres Doktorandenseminar CY - Berlin, Germany DA - 24.02.2013 KW - Quantitative Online-NMR-Spektroskopie KW - Pharmazeutische Cokristalle PY - 2013 SN - 978-3-9815360-9-6 SP - 9 EP - 11 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) AN - OPUS4-28266 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - García Fernández, J. A1 - Sánchez-González, C. A1 - Bettmer, J. A1 - Llopi, J. A1 - Jakubowski, Norbert A1 - Panne, Ulrich A1 - Montes-Bayón, M. T1 - Quantitative assessment of the metabolic products of iron oxide nanoparticles to be used as iron supplements in cell cultures N2 - Iron nanoparticles (NPs) metabolism is directly associated to human health due to their use as anemia treatment and should be studied in detail in cells. Here we present a speciation strategy for the determination of the metabolic products of iron oxide nanoparticles coated by tartaric and adipic acids in enterocytes-like cell models (Caco-2 and HT-29). Such methodology is based on the use of SDS-modified reversed phase high performance liquid chromatography (HPLC) separation using inductively coupled plasma-mass spectrometry (ICP-MS) as Fe selective detector. Post-column isotope dilution analysis is used as quantification tool by adding Fe-57 as isotopically enriched standard. To assess the separation capability of the method, two different iron nanostructures: iron sucrose nanoparticles -Venofer®- used as model suspension and iron tartrate/adipate-modified nanoparticles, both of about 4 nm (core size) were evaluated. The two nanostructures were injected into the system showing good peak profiles and quantitative elution recoveries (>80%) in both cases. In addition, both nanoparticulate fractions could be based-line separated from ionic iron species, which needed to be complexed with 1mM citrate to elute from the column. Exposed cells up to 0.5mM of iron tartrate/adipate-modified nanoparticles were specifically treated to extract the internalized NPs and the extracts examined using the proposed strategy. The obtained results revealed the presence of three different fractions corresponding to nanoparticle aggregates, dispersed nanoparticles and soluble iron respectively in a single chromatographic run. Quantitative experiments (column recoveries ranging from 60 to 80%) revealed the presence of the majority of the Fe in the nanoparticulated form (>75%) by summing up the dispersed and aggregate particles. Such experiments point out the high uptake and low solubilization rate of the tartrate/adipate NPs making these structures highly suitable as Fe supplements in oral anemia treatments. KW - Fe nanoparticles metabolism KW - Cells KW - HPLC-ICP-MS KW - Species-unspecific on-line isotope dilution PY - 2018 DO - https://doi.org/10.1016/j.aca.2018.08.003 SN - 0003-2670 VL - 1039 SP - 24 EP - 30 PB - Elsevier CY - Amsterdam AN - OPUS4-46817 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Löhr, Konrad A1 - Traub, Heike A1 - Wanka, Antje Jutta A1 - Panne, Ulrich A1 - Jakubowski, Norbert T1 - Quantification of metals in single cells by LA-ICP-MS: Comparison of single spot analysis and imaging N2 - LA-ICP-MS is increasingly used for single cell analysis in two different detection modes using either the imaging mode with subcellular resolution or alternatively single spot analysis of cells with a larger laser spot size. This study compares the analytical figures of merit of both detection modes (signal to noise, precision, accuracy, throughput), as well as ease of operation and data evaluation. Adherent 3T3 fibroblast cells were stained with two metal dyes (mDOTA-Ho, Ir-DNA-intercalator) and several dozen cells were measured using both modes. We found a ten times higher throughput for single spot analysis, which has as well a straightforward data analysis, shortening the total analysis time further. The signal to noise ratio for single spot analysis was found to be slightly better compared to the signal to noise of pixels in imaging. The mean metal intensity per single cell differed by only 10% between both modes and obtained distributions were found to show no statistically significant differences. Using matrix matched calibration based on standards spotted onto nitrocellulose membrane, we achieved detection limits (10s) of 12 fg for Ir and 30 fg for Ho and quantified 57 +/-35 fg Ir and 1192 +/- 707 fg Ho per single cell. Compared to a conventional ICP-MS measurement of a digest of about 60000 cells, 54% of Ir content and 358% Ho content was found using quantitative LA-ICP-MS. The difference might be a consequence of the two metal dyes binding to different structures of the cell and therefore might behave differently in sample preparation for conventional and LA-ICP-MS. KW - Cells KW - Laser ablation KW - ICP-MS KW - Metals KW - Quantification PY - 2018 DO - https://doi.org/10.1039/c8ja00191j SN - 0267-9477 VL - 33 IS - 9 SP - 1579 EP - 1587 PB - RSC Royal Society of Chemistry CY - London AN - OPUS4-46441 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Loehr, Konrad A1 - Jakubowski, Norbert A1 - Wanka, Antje Jutta A1 - Traub, Heike A1 - Panne, Ulrich T1 - Quantification of metals in single cells by LA-ICP-MS comparison of single spot analysis and imaging N2 - LA-ICP-MS is increasingly used for single cell analysis in two different detection modes using either the imaging mode with subcellular resolution or alternatively single spot analysis of cells with a larger laser spot size. This study compares the analytical figures of merit of both detection modes (signal to noise, precision, accuracy, throughput), as well as ease of operation and data evaluation. Adherent 3T3 fibroblast cells were stained with two metal dyes (mDOTA-Ho, Ir-DNA-intercalator) and several dozen cells were measured using both modes. We found a ten times higher throughput for single spot analysis, which has as well a straightforward data analysis, shortening the total analysis time further. The signal to noise ratio for single spot analysis was found to be slightly better compared to the signal to noise of pixels in imaging. The mean metal intensity per single cell differed by only 10% between both modes and obtained distributions were found to show no statistically significant differences. Using matrix matched calibration based on standards spotted onto nitrocellulose membrane, we achieved detection limits (10 σ) of 12 fg for Ir and 30 fg for Ho and quantified 57 ± 35 fg Ir and 1,192 ± 707 fg Ho per single cell. Compared to a conventional ICP-MS measurement of a digest of ~60,000 cells, 54 % of Ir content and 358 % Ho content was found using quantitative LA-ICP-MS. The difference might be a consequence of the two metal dyes binding to different structures of the cell and therefore might behave differently in sample preparation for conventional and LA-ICP-MS. KW - Single cell analysis KW - LA-ICP-MS PY - 2018 DO - https://doi.org/10.1039/c8ja00191j SN - 0267-9477 SN - 1364-5544 VL - 33 IS - 9 SP - 1579 EP - 1587 PB - Royal Society of Chemistry AN - OPUS4-45903 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Shigeta, K. A1 - Koellensperger, G. A1 - Rampler, E. A1 - Traub, Heike A1 - Rottmann, L. A1 - Panne, Ulrich A1 - Okino, A. A1 - Jakubowski, Norbert T1 - Sample introduction of single selenized yeast cells (Saccharomyces cerevisiae) by micro droplet generation into an ICP-sector field mass spectrometer for label-free detection of trace elements N2 - We have applied a micro droplet generator (µDG) for sample introduction of single selenized yeast cells into a sector field ICP-MS, which was operated in a fast scanning mode with sampling rates of up to 10 kHz, to measure single cells time resolved with 100 µs integration time. Selenized yeast cells have been used as a model system for preliminary investigation. The single cells to be measured have been embedded into droplets and it will be shown that the time duration of a single cell event always is about 400 to 500 µs, and thus comparable to the time duration of a droplet without a cell. A fixed droplet generation rate of 50 Hz produced equidistant signals in time of each droplet event and was advantageous to separate contribution from background and blank from the analytical signal. Open vessel digestion and a multielement analysis were performed with washed yeast cells and absolute amounts per single cell were determined for Na (0.91 fg), Mg (9.4 fg), Fe (5.9 fg), Cu (0.54 fg), Zn (1.2 fg) and Se (72 fg). Signal intensities from single cells have been measured for the elements Cu, Zn and Se, and histograms were calculated for about 1000 cell events. The mean elemental sensitivities measured here range from 0.7 counts per ag (Se) to 10 counts per ag (Zn) with RSD's from 49% (Zn) to 69% (Se) for about 1000 cell events. PY - 2013 DO - https://doi.org/10.1039/c3ja30370e SN - 0267-9477 SN - 1364-5544 VL - 28 IS - 5 SP - 637 EP - 645 PB - Royal Society of Chemistry CY - London AN - OPUS4-29448 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Panne, Ulrich T1 - Chemometric tools for LIBS analysis N2 - LIBS matures to a quantitative method for elemental analysis rather than a qualitative diagnostic tool. Numerous real world applications for bulk and microanalysis profit from instrumental and methodical advances in the last decade. Today, recording of numerous spectra from samples can be done with low experimental efforts and low cost per spectrum. Not surprisingly, LIBS data, with a high spectral resolution and a broad spectral range, become “big data” and can be utilized in different ways beyond elemental analysis. But, what is the generic or best approach for quantitative LIBS analysis? What techniques can be employed to gain new insights into data? Emergent information can arise through data fusion of LIBS data with other data, i.e. orthogonal spectroscopic or other information related to the sample. But are fused data better than data from a single method? This talk will provide an in-depth overview what chemometric tools can do for LIBS. For quantitative analysis, pre-processing tools are essential to improve precision, accuracy, and reproducibility but at the same time their application to data is still based on phenomenological criteria. Multivariate analysis seems to dominate LIBS, but are there drawbacks on using all information from spectra. For different data sets from real applications, the use of multivariate calibration and (un)supervised pattern recognition will be discussed in comparison with reference analytical methods and possible improvements through plasma diagnostics and modelling. T2 - 9th International Confrence on Laser-Indusced Breakdown Spectroscopy (LIBS) CY - Charmonix-Mont-Blanc, France DA - 12.09.2016 KW - Chemometrics KW - Analytical method KW - LIBS PY - 2016 AN - OPUS4-37534 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gopala, Anil A1 - Kipphardt, Heinrich A1 - Matschat, Ralf A1 - Panne, Ulrich T1 - Process methodology for the small scale production of m6N5 purity zinc using a resistance heated vacuum distillation system N2 - Ultra high purity Zn (m6N5) was obtained through triple vacuum distillation using an m4N5 Zn as input material. High-volatile impurities were removed from the zinc matrix by vacuum evaporation, while traces having lower volatility than the matrix remained in the residual material after finishing of the entire purification process. The time required for the removal of the main high-volatile impurity (Cd) was monitored using a connected gas source mass spectrometer. During distillation the Zn vapor of the distillate was condensed on the cap of a glassy carbon crucible which was water cooled by a movable copper block. The temperatures were optimized for the removal of the volatiles and for the distillation process using vapor pressure data. High resolution glow discharge mass spectrometry was applied for the analysis and purity evaluation of the distilled and input zinc. The analysis confirmed the reduction of the metallic impurities from 43 mg kg-1 to 0.5 mg kg-1 (m6N5) after three consecutive vacuum distillations. An increase in the grain size and a decrease in the micro-hardness were observed for the purified Zn material. KW - Ultra high purity KW - Vacuum distillation KW - High resolution glow discharge mass KW - Spectrometry KW - Micro-hardness KW - Zinc KW - Purification PY - 2010 DO - https://doi.org/10.1016/j.matchemphys.2010.02.080 SN - 0254-0584 VL - 122 IS - 1 SP - 151 EP - 155 PB - Elsevier CY - Amsterdam AN - OPUS4-21127 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Garcia-Fernandez, J. A1 - Turiel, D. A1 - Bettmer, J. A1 - Jakubowski, Norbert A1 - Panne, Ulrich A1 - Rivas Garcia, L. A1 - Llopis, J. A1 - Sanchez-Gonzalez, C. A1 - Montes-Bayon, M. T1 - In vitro and in situ experiments to evaluate the biodistribution and cellular toxicity of ultrasmall iron oxide nanoparticles potentially used as oral iron supplements N2 - Well-absorbed iron-based nanoparticulated materials are a promise for the oral management of iron deficient anemia. In this work, a battery of in vitro and in situ experiments are combined for the evaluation of the uptake, distribution and toxicity of new synthesized ultrasmall (4 nm core) Fe2O3 nanoparticles coated with tartaric/adipic acid with potential to be used as oral Fe supplements. First, the in vitro simulated gastric acid solubility studies by TEM and HPLC-ICP-MS reveal a partial reduction of the core size of about 40% after 90 min at pH3. Such scenario confirms the arrival of the nanoparticulate material in the small intestine. In the next step, the in vivo absorption through the small intestine by intestinal perfusion experiments is conducted using the sought nanoparticles in Wistar rats. The quantification of Fe in the NPs Suspension before and after perfusion shows Fe absorption levels above 79%, never reported for other Fe treatments. Such high absorption levels do not seem to compromise cell viability, evaluated in enterocytes-like models (Caco-2 and HT-29) using cytotoxicity, ROS production, genotoxicity and lipid peroxidation tests. Moreover, regional differences in terms of Fe concentration are obtained among different parts of the small intestine as duodenum>jejunum>ileum. Complementary transmission electron microscopy (TEM) images show the presence of the intact particles around the intestinal microvilli without significant tissue damage. These studies show the high potential of these NP preparations for their use as oral management of anemia. KW - Iron nanoparticles KW - Anemia KW - ICP-MS KW - In vitro KW - In situ PY - 2020 DO - https://doi.org/10.1080/17435390.2019.1710613 VL - 14 IS - 3 SP - 388 EP - 403 PB - Taylor & Francis Online CY - London AN - OPUS4-50314 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Chinthalapati, Siva Kesava Raju A1 - Lück, Detlef A1 - Scharf, Holger A1 - Jakubowski, Norbert A1 - Panne, Ulrich T1 - A novel solid phase extraction method for pre-concentration of gadolinium and gadolinium based MRI contrast agents from the environment N2 - An efficient solid phase extraction (SPE) method using bis-(2-ethylhexyl)-phosphate (HDEHP) coated reverse phase C18 support has been developed for the pre-concentration of Gadolinium (Gd) and Gd contrast agents widely used in magnetic resonance imaging (MRI). Enrichment of Gd in the ionic form has been compared with strong cation exchange material Chromabond SA (SCX), weak ion exchange material Chelex-100 and also with lanthanide specific HDEHP modified reverse phase C18. The determination of Gd and its complexes after enrichment were performed using inductively coupled plasma mass spectrometry (ICP-MS) and on the basis of 158Gd. Among the three SPE materials, HDEHP coated reverse phase C18 SPE has been found to be most efficient, yielding a hundredfold Gd enrichment with > 95% recovery for linear and cyclic contrast agents like Gd-DTPA (Magnevist), Gd-DOTA (Dotarem), Gd-BOPTA (Multihance), and Gd-BT-DO3A (Gadovist). The developed SPE method has been successfully applied to the surface water and waste water samples originated from different places in Berlin, Germany. The results were in good agreement with the results obtained with direct measurement with ICP-MS. The developed pre-concentration method can be efficiently used for the determination of trace levels of gadolinium in the environment even with less sensitive analytical techniques. KW - Solid phase extraction KW - Magnetic resonance imaging KW - Gadolinium KW - Gd based contrast agents KW - Chelex-100 KW - HDEHP KW - Speciation PY - 2010 DO - https://doi.org/10.1039/c003251d SN - 0267-9477 SN - 1364-5544 VL - 25 IS - 10 SP - 1573 EP - 1580 PB - Royal Society of Chemistry CY - London AN - OPUS4-21985 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Chinthalapati, Siva Kesava Raju A1 - Cossmer, Antje A1 - Scharf, Holger A1 - Panne, Ulrich A1 - Lück, Detlef T1 - Speciation of gadolinium based MRI contrast agents in environmental water samples using hydrophilic interaction chromatography hyphenated with inductively coupled plasma mass spectrometry KW - HPLC-ICP-MS KW - HILIC chromatography KW - Speciation KW - Gadolinium KW - MRI contrast agent PY - 2010 DO - https://doi.org/10.1039/b919959d SN - 0267-9477 SN - 1364-5544 VL - 25 SP - 55 EP - 61 PB - Royal Society of Chemistry CY - London AN - OPUS4-20705 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Merk, Sven A1 - Demidov, Alexandr A1 - Shelby, D. A1 - Gornushkin, Igor B. A1 - Panne, Ulrich A1 - Smith, B.W. A1 - Omenetto, N. T1 - Diagnostic of laser-induced plasma using Abel inversion and radiation modeling N2 - A method based on matching synthetic and experimental emissivity spectra was applied to spatially resolved measurements of a laser-induced plasma ignited in argon at atmospheric pressure. The experimental emissivity spectra were obtained by Abel inversion of intensity spectra measured from a thin plasma slice perpendicular to the plasma axis. The synthetic spectra were iteratively calculated from an equilibrium model of plasma radiation that included free free, free–bound, and bound–bound transitions. From both the experimental and synthetic emissivity spectra, spatial and temporal distributions of plasma temperature and number densities of plasma species (atoms, ions, and electrons) were obtained and compared. For the best-fit synthetic spectra, the temperature and number densities were read directly from the model; for experimental spectra, these parameters were obtained by traditional Boltzmann plot and Stark broadening methods. In both cases, the same spectroscopic data were used. Two approaches revealed a close agreement in electron number densities, but differences in plasma excitation temperatures and atom number densities. The trueness of the two methods was tested by the direct Abel transform that reconstructed the original intensity spectra for comparing them to the measured spectra. The comparison yielded a 9 and 13% difference between the reconstructed and experimental spectra for the numerical and traditional methods, respectively. It was thus demonstrated that the spectral fit method is capable of providing more accurate plasma diagnostics than the Boltzmann plot and Stark broadening methods. KW - Abel inversion KW - Laser-induced plasma KW - LIBS KW - Plasma spectrum analysis PY - 2013 DO - https://doi.org/10.1366/12-06929 SN - 0003-7028 SN - 1943-3530 VL - 67 IS - 8 SP - 851 EP - 859 PB - Society for Applied Spectroscopy CY - Frederick, Md. AN - OPUS4-30433 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Herrmann, Antje Jutta A1 - Techritz, Sandra A1 - Jakubowski, Norbert A1 - Haase, A. A1 - Luch, A. A1 - Panne, Ulrich A1 - Müller, Larissa T1 - A simple metal staining procedure for identification and visualization of single cells by LA-ICP-MS N2 - High lateral resolution of metal detection in single cells by use of laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) demands powerful staining methods. In this work different staining procedures for the single cell analysis with LA-ICP-MS were optimized. An iridium intercalator was utilized to stain the cell nuclei whereas the whole cell was stained by the use of maleimido-mono-amide-DOTA (mDOTA) complexing lanthanide(III) ions. The content of the artificially introduced metals per cell was quantified using a matrix matched calibration approach based on cellulose membranes onto which standards were spotted by a microarray spotter. Absolute metal stain amounts in the range of 2.34 to 9.81 femtomole per cell were determined. The metal staining procedures allow direct identification and visualization of single cells and their cell compartments by element microscopy without the use of bright field images of the sample. KW - Single Cell Analysis KW - Bioimaging KW - LA-ICP-MS based immunoassays PY - 2017 DO - https://doi.org/10.1039/c6an02638a SN - 0003-2654 SN - 1364-5528 VL - 142 IS - 10 SP - 1703 EP - 1710 PB - The Royal Society of Chemistry AN - OPUS4-40251 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Panne, Ulrich T1 - Mit Sicherheit vorn - Analytische Chemie an der BAM T2 - DGCh-Kolloquium, Universität Hamburg CY - Hamburg, Germany DA - 2006-12-07 PY - 2006 AN - OPUS4-13117 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schulte, Franziska A1 - Brzezinka, K.-W. A1 - Lutzenberger, K. A1 - Stege, H. A1 - Panne, Ulrich T1 - Raman spectroscopy of synthetic organic pigments used in 20th century works of art N2 - Raman microscopy allows a non-destructive characterisation of inorganic and organic painting materials such as pigments and organic dyestuffs. The objectives of this study are the more recent organic pigments typically present in paintings and other art works from the 20th century. More than 20 organic synthetic pigments from different chemical classes could be identified by Raman spectroscopy using different excitation wavelengths (457.9, 476.5, 487.9, 514.5, 632.8, and 1064 nm). To evaluate the performance for real paint samples, varying paint mixtures of the Hansa Yellow pigment PY 3 and the binding medium Mowilith, a polyvinyl acetate (PVAC) compound, were characterised; PY 3 was determined at a 1 wt% level in the binder. In addition, commercial tube paints containing the quinacridone violet PV 19 were studied. The pigment was clearly identified in all of these more complex oil and acrylic paints. Finally, alizarin (PR 83) and a green copper phthalocyanine pigment (PG 7) could unambiguously be identified by Raman microscopy in the painting Woman with mandolin in yellow and red of Max Beckmann dating 1950. The discovery of a red naphthol AS pigment by Raman spectroscopy in a sample from the Three field workers by Georg Baselitz (1964/1965) demonstrated that in some cases complementary chromatographic methods are needed for a comprehensive identification of the organic pigments. KW - Raman microscopy KW - FT-Raman spectroscopy KW - Synthetic organic pigments KW - Modern art PY - 2008 DO - https://doi.org/10.1002/jrs.2021 SN - 0377-0486 SN - 1097-4555 VL - 39 IS - 10 SP - 1455 EP - 1463 PB - Wiley CY - Chichester AN - OPUS4-18401 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Lange, Britta A1 - Recknagel, Sebastian A1 - Czerwensky, Michael A1 - Matschat, Ralf A1 - Michaelis, Matthias A1 - Peplinski, Burkhard A1 - Panne, Ulrich T1 - Analysis of pure copper - a comparison of analytical mehods KW - Pure copper KW - Elemental analytical mehtods KW - Reference material KW - Sample dissolution PY - 2008 DO - https://doi.org/10.1007/s00604-007-0849-1 SN - 0026-3672 SN - 1436-5073 VL - 160 SP - 97 EP - 107 PB - Springer CY - Wien AN - OPUS4-17565 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schulte, Franziska A1 - Lingott, J. A1 - Panne, Ulrich A1 - Kneipp, Janina T1 - Chemical characterization and classification of Pollen N2 - We report on the in situ characterization of tree pollen molecular composition based on Raman spectroscopy. Different from purification-based analysis, the nondestructive approach allows (i) to analyze various classes of molecules simultaneously at microscopic resolution and (ii) to acquire fingerprint-like chemical information that was used for the classification of pollen from different species. Hierarchical cluster analysis of spectra from fresh pollen samples of 15 species partly related at the genus level and family level indicates separation of species based on the complete Raman spectral signature and yields classification in accord with biological systematics. The results have implications for the further elucidation of pollen biochemistry and also for the development of chemistry-based online pollen identification methods. PY - 2008 DO - https://doi.org/10.1021/ac801791a SN - 0003-2700 SN - 1520-6882 SP - 1 EP - 12 PB - American Chemical Society CY - Washington, DC AN - OPUS4-18234 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Eichelbaum, M. A1 - Kneipp, Janina A1 - Schmidt, B.E. A1 - Panne, Ulrich A1 - Rademann, K. T1 - SERS and Multiphoton-Induced Luminescence of Gold Micro- and Nanostructures Fabricated by NIR Femtosecond-Laser Irradiation KW - Gold KW - Luminescence KW - Multiphoton fabrication KW - Sol-gel processes KW - Surface-enhanced Raman scattering PY - 2008 DO - https://doi.org/10.1002/cphc.200800417 SN - 1439-4235 SN - 1439-7641 VL - 9 IS - 15 SP - 2163 EP - 2167 PB - Wiley-VCH Verl. CY - Weinheim AN - OPUS4-18233 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Müller, Maike A1 - Gornushkin, Igor B. A1 - Florek, S. A1 - Mory, D. A1 - Panne, Ulrich T1 - Approach to Detection in Laser-Induced Breakdown Spectroscopy N2 - Gated detection with intensified detectors, e.g., ICCDs, is today the accepted approach for detection of plasma emission in laser-induced breakdown spectroscopy (LIBS). However, these systems are more cost-intensive and less robust than nonintensified CCDs. The objective of this paper is to compare, both theoretically and experimentally, the performance of an intensified (ICCD) and nonintensified (CCD) detectors for detection of plasma emission in LIBS. The CCD is used in combination with a mechanical chopper, which blocks the early continuum radiation from the plasma. The detectors are attached sequentially to an echelle spectrometer under the same experimental conditions. The laser plasma is induced on a series of steel samples under atmospheric conditions. Our results indicate that there is no substantial difference in the performance of the CCD and ICCD. Signal-to-noise ratios and limits of detection achieved with the CCD for Si, Ni, Cr, Mo, Cu, and V in steel are comparable or even better than those obtained with the ICCD. This result is further confirmed by simulation of the plasma emission signal and the corresponding response of the detectors in the limit of quantum (photon) noise. KW - LIBS KW - Detektorvergleich KW - ICCD CCD PY - 2007 DO - https://doi.org/10.1021/ac0621470 SN - 0003-2700 SN - 1520-6882 VL - 79 IS - 12 SP - 4419 EP - 4426 PB - American Chemical Society CY - Washington, DC AN - OPUS4-15044 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Panne, Ulrich T1 - The potential of laser-induced plasma spectroscopy (LIBS) for elemental process analysis T2 - 1st European Conference on Process Analytics and Control Technology CY - Frankfurt am Main, Germany DA - 2008-04-22 PY - 2008 AN - OPUS4-17761 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Panne, Ulrich T1 - Mit Sicherheit vorn - Analytische Chemie an der BAM T2 - DGCh-Vortrag, Universität Hannover CY - Hanover, Germany DA - 2008-05-08 PY - 2008 AN - OPUS4-17762 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -