TY - JOUR A1 - Romero Navarrete, J. A. A1 - Otremba, Frank A1 - Lozano Guzmán, A. A. T1 - Liquid cargo effect on load transfer under orthogonal accelerations N2 - A methodology is proposed for the experimental analysis of the liquid cargo effect under combined orthogonal accelerations. To simultaneously subject the vehicle-cargo system to longitudinal and lateral accelerations, the vehicle is set obliquely on a tilt table. The experimental outputs suggest that there is a significant effect of the liquid cargo on the lateral load transfer ratio (LTR), on the order of 20%, which is attributable to the resulting shifting of the liquid cargo’s centre of gravity. That is, the peak LTR values due exclusively to sloshing were not significant, in such a way that the liquid cargo would only pose a safety risk under a steady acceleration input. Also, the inverse of the product of the magnitude of the acceleration times the free surface length, correlates with the liquid cargo effect. That is, the magnitude of the input acceleration is not fully determinant for greater load transfers. KW - Sloshing KW - Liquid cargo KW - Cargo shifting KW - Lateral load transfer KW - Braking in a turn manoeuvre KW - Experimental methods KW - Transport safety PY - 2022 DO - https://doi.org/10.1504/ijhvs.2022.127011 SN - 1744-232X VL - 29 IS - 3 SP - 213 EP - 226 PB - Inderscience Enterprises CY - Geneva AN - OPUS4-56016 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Jauregui-Correa, J. C. A1 - Otremba, Frank A1 - Hurtado-Hurtado, G. A1 - Romero-Navarrete, J. A. T1 - Experimental test rig for simulating dynamic loads on subway systems N2 - Scaled-down experimental facility: Can reproduce actual failures; can produce simulated data for identifying cracks in the substructure or other defects. The acceleration data can be converted into an equivalent deformation. The experimental facility can analyse dynamic loads. Equivalent force data: Facilitates the application to a health monitoring system; simplifies the development of predictive maintenance. These data is helpful in validating analytical or simulation models. T2 - Fifth International Conference on Railway Technology CY - Montpellier, France DA - 22.08.2022 KW - Test rig KW - Dynamic loads KW - Subway system PY - 2020 SP - 1 EP - 6 AN - OPUS4-55566 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Jauregui-Correa, J. C. A1 - Otremba, Frank A1 - Hurtado-Hurtado, G. A1 - Romero-Navarrete, J. A. T1 - Experimental test rig for simulating dynamic loads on subway systems N2 - Degradation in substructures, Mexico’s City Subway. Improve predictions using vibration Measurements. Ability to test operating conditions at Laboratory. Improve previous laboratory rig. Control operating conditions. Produce enough data for evaluating actual conditions. T2 - Fifth International Conference on Railway Technology CY - Montpellier, France DA - 22.08.2022 KW - Test rig KW - Simulating KW - Dynamic loads KW - Subway PY - 2022 AN - OPUS4-55568 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Otremba, Frank A1 - Romero Navarrete, J. A. T1 - Assesing rail damage in turns due to lateral load transfer N2 - A testing procedure is proposed and used, to estimate the rail damage potentials of variations in both, the height of the cargo´s center of gravity and the railway car suspension´s spring constant. The experimental setup consist ed of a tilt table that slowl y exer ted an increasing lateral acceleration on a two axle bog ie type vehicle equipped with a spring supported container. The potential damaging effect derived from the resulting lateral load transfer, was assessed on the basis of the fourth power law. Results suggest that the cargo having a higher center of gravity could be more damagi ng to the outside rail when compared with the effect of the shorter center of gravity of the cargo, in a range from 0.94% to 3.17%, as a function of the spring constant of the suspension. Consequently and comparatively there would be a long term damaging effect on the rail when having a cargo with a high er center of gravity, so that specific cargo, having a high center of would be more aggressive to the infrastructure On the other hand for the range of time rate changes of the lateral acceleration, it was not found a consisten t trend regarding the effect of the value of the spring constant on the magnitude of the load transfers . T2 - IMECE 2024 CY - Portland, Oregon, USA DA - 17.11.2024 KW - Railway damage KW - Load transfer KW - Fourth power law KW - Experimental methods KW - Center of gravity KW - Tilt table KW - Suspension spring constant PY - 2024 SN - 978-0-7918-8869-8 SP - 1 EP - 4 PB - ASME AN - OPUS4-61785 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Camplese, Davide A1 - Cozzolino, Chiara A1 - Scarponi, Giordano Emrys A1 - Eberwein, Robert A1 - Otremba, Frank A1 - Cozzani, Valerio T1 - Safety Assessment of MLI Super-Insulation Systems for Cryogenic Liquid-Hydrogen Tanks in Fire Scenarios N2 - In the context of green energy transition, cryogenic tanks insulated by MLI and vacuum are emerging as a leading solution to store hydrogen in heavy-duty vehicles. However, the integrity of such tanks can be jeopardized by fire. In such a scenario, MLI materials degradation can occur, leaving the tank unprotected from the fire heat flux, with consequent rapid pressurization and a high risk of failure. This study presents a safety assessment of non-combustible MLI under fire exposure based on the estimation of the time to mechanical failure of the equipment. This is calculated through an innovative model that simulates the thermomechanical response of the tank, including the MLI thermal degradation and the pressure-relief valve (PRV) operation. The application to several case studies that consider a typical LH2 tank featuring a wide range of MLI configurations demonstrated the likelihood of failure in case of exposure to a hydrocarbon pool fire, providing also comprehensive insights into the impact of the insulation characteristics and operating conditions on the time to failure. T2 - Loss Prevention 2025 CY - Bologna, Italien DA - 09.06.2025 KW - LH2 KW - LNG KW - Fire KW - Insulation KW - Safety KW - Tank PY - 2025 DO - https://doi.org/10.3303/CET25116036 SN - 2283-9216 IS - 116 SP - 211 EP - 216 PB - AIDIC AN - OPUS4-63739 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Eberwein, Robert A1 - Hajhariri, Aliasghar A1 - Davide, Camplese A1 - Giordano, Emrys Scarponi A1 - Valerio, Cozzani A1 - Frank, Otremba T1 - Experimental investigation on the behavior of thermal super insulation materials for cryogenic storage tanks in fire incidents N2 - The number of vehicles using or transporting cryogenic fuels such as Liquefied Hydrogen (LH2) or Liquefied Natural Gas (LNG) increases fast in the land transportation sector. Does this also entail new risks? The storage of cryogenic fuels requires tanks with Thermal Super Insulations (TSI) to keep the fluid cold and limit the formation of boil-off gas. TSI has proven itself in some applications since the middle of the 20th century, but in the land transport sector they are still quite new, where accidents involving fires, collisions, and their combination are to be expected. This work focuses on investigating the behavior of different types of TSI while exposed to a heat source representing a fire. To this aim, a High-Temperature Thermal Vacuum Chamber (HTTVC) was applied, which allows the thermal loading of a thermal insulation material in a vacuum and measuring the heat flow transported through the TSI in parallel. In this study, the results of 6 samples are presented regarding 3 types of MLI, rock wool, perlites, and microspheres. The thermal exposure caused different effects on the samples. In practice, this can be connected to the rapid release of flammable gases as well as to a Boiling Liquid Expanding Vapour Explosion (BLEVE). These results are relevant for reducing the risks to people and infrastructures in the progressive establishment of tanks for cryogenic fluids in our industry and society. The data presented in the study can be used to improve the design of tanks and TSIs, the assessment of accident scenarios, and the development of measures for first responders. KW - Liquefied hydrogen KW - Liquefied natural gas KW - Tanks KW - Fire KW - Insulation KW - MLI KW - Perlite KW - Rock wool KW - Microspheres PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-599947 DO - https://doi.org/10.1016/j.psep.2024.04.131 SN - 0957-5820 VL - 187 SP - 240 EP - 248 PB - Elsevier AN - OPUS4-59994 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Eberwein, Robert A1 - Hajhariri, Aliasghar A1 - Camplese, D. A1 - Scarponi, G. E. A1 - Cozzani, V. A1 - Otremba, Frank T1 - Insulation Materials Used in Tanks for the Storage of Cryogenic Fluids in Fire Scenarios N2 - The importance of tanks for storing cryogenic fluids in the energy industry is increasing because of ongoing political conflicts and the implementation of more environmentally friendly energy sources. Key representatives for the application of cryogenic tanks are natural gas in the form of Liquefied Natural Gas (LNG) and hydrogen, e. g. in the form of Liquefied Hydrogen (LH2), for which significantly higher transport capacities can be achieved with the same transport volume using cryogenic storages than with storages based solely on overpressure. What applies to all cryogenic transported fluids in common is their condition that must be maintained. Hence heat flows into the preserved fluid must be minimized. Thermal super Insulations (TSI) based on e. g. multilayer insulations (MLI), perlites, and vacuum are utilized for this purpose and have already proven themselves in similar applications. However, for the use of tanks for cryogenic fluids in the transport sector, there is insufficient knowledge regarding the course and consequences of incidents, which is due to the still short period of use and the few documented incidents, hence few investigations carried out in this field. Typical scenarios in the transport sector represent car accidents with collisions, fires, and their combination, which are associated with extraordinary loads on the tank. The focus of this study is to investigate the behavior of TSI as a result of their thermal exposure to a heat source representing a fire. It is worth mentioning that this could lead to an increase of the heat flux into a tank by several orders of magnitude, and to permanent damage of the TSI, ultimately rapid release of flammable gas as well as a Boiling Liquide Expanding Vapour Explosion (BLEVE). For this purpose, a high temperature thermal vacuum chamber (HTTVC) has been developed that allows thermal loading of MLI or perlites in a vacuum and simultaneous measurement of heat flow through this TSI. The HTTVC is designed to represent realistic insulation conditions and to withstand thermal loads from typical design fires. The HTTVC was applied to investigate TSI based on MLI and vacuum. It is shown that the thermal stress caused permanent damage to the TSI, with shrinkage, phase change, pyrolysis, and condensation being significant damage mechanisms. The results are relevant for the evaluation of accident scenarios and can thus contribute to the improvement of TSI and the development of emergency measures for the protection of persons and infrastructures. T2 - ASME 2023 Pressure Vessels & Piping Conference (PVP2023) CY - Atlanta, Georgia, USA DA - 16.07.2023 KW - LH2 KW - LNG KW - Fire KW - MLI KW - Safety PY - 2023 AN - OPUS4-57974 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Eberwein, Robert A1 - Heßmann, Jennifer A1 - Werner, Jan A1 - Scarponi, Giordano Emrys A1 - Cozzani, Valerio A1 - Otremba, Frank T1 - Investigation of realistic fire scenarios involving cryogenic storage tanks N2 - The number of vehicles using or transporting cryogenic fuels such as Liquefied Hydrogen (LH2) or Liquefied Natural Gas (LNG) increases fast in the land transportation sector. Does this also entail new risks for instance from a BLEVE? A key to answer this question is to research representative fires by its characterization and its effect on the insulation. At BAM’s technical test side in Germany, a test series was started to answer this question among others. This paper presents results on a pool fire under a colorimeter, that simulates a tank. The investigation points out, that the full fire characterization approach allows to represent the fire. The findings are relevant for the investigation of a representative design fire that is applicable for the approval and improvement of tanks as well as to research accident scenarios and their consequences. T2 - 18th EFCE International Symposium on Loss Prevention and Safety Promotion in the Process Industries CY - Bologna, Italy DA - 08.06.2025 KW - LH2 KW - Insulation KW - Fire KW - Liquefied Natural Gas KW - Safety PY - 2025 AN - OPUS4-63425 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Otremba, Frank T1 - Systems with Cryogenic Liquefied Gases in Fire Incidents N2 - Liquefied Hydrogen (LH2) or Liquefied Natural Gas (LNG) establish themselves as important energy carriers in the transport sector. Its storage requires tanks with Thermal Super Insulations (TSI) to keep the transported fluid cold. TSI has proven itself in various applications over a long time, but not in the land transport sector, where accidents involving collisions, fires, and their combination are to be expected. The focus of this study is to investigate the behavior of different types of TSI when exposed to a heat source that represents a fire. Therefore, a High- Temperature Thermal Vacuum Chamber (HTTVC) was used that allows the thermal loading of thermal insulation material in a vacuum and measuring the heat flow through the TSI in parallel. Within this study, 5 samples were tested regarding 3 different types of MLI, rock wool, and perlites. The thermal exposure caused different effects on the samples. In practice, this can be connected to the rapid release of flammable gases as well as a Boiling Liquid Expanding Vapour Explosion (BLEVE). These results are relevant for the evaluation of accident scenarios, the improvement of TSI, and the development of emergency measures. T2 - IMECE 2023 CY - New Orleans, Louisiana, USA DA - 29.10.2023 KW - LH2 KW - LNG KW - Fire PY - 2023 AN - OPUS4-58769 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hajhariri, Aliasghar A1 - Eberwein, Robert A1 - Perrone, Luca Pakj A1 - Cozzani, Valerio A1 - Otremba, Frank A1 - Seidlitz, Holger T1 - Study the impact of spacer at thermal degradation process of MLI-based insulation in fire condition N2 - To reduce CO2 emissions, energy carriers such as hydrogen are considered to be a solution. Consumption of hydrogen as a fuel meets several limitations such as its low volumetric energy density in gas phase. To tackle this problem, storage as well as transportation in liquified phase is recommended. To be able to handle this component in liquid phase, an efficient thermal insulation e.g., MLI insulation is required. Different studies have been addressed the vulnerability of such insulation against high thermal loads e.g., in an accident engaging fire. Some of research works have highlighted the importance of considering the MLI thermal degradation focusing on its reflective layer. However, limited number of studies addressed the thermal degradation of spacer material and its effect on the overall heat flux. In this study, through systematic experimental measurements, the effect of thermal loads on glass fleece, glass paper as well as polyester spacers are investigated. The results are reported in various temperature and heat flux profiles. Interpreting the temperature profiles revealed that, as the number of spacers in the medium increases, the peak temperature detectable by the temperature sensor on the measurement plate decreases. Each individual spacer contributes to mitigating the radiative energy received by the measurement plate. Stacks of 20–50 spacers (this is the number of layers in commercial MLI systems applied for liquid hydrogen applications) can potentially reduce the thermal radiation by 1–2 orders of magnitude. An empirical correlation to predict a heat flux attenuation factor is proposed, which is useful for further numerical and analytical studies in the temperature range from ambient to 300 ◦C. KW - Cryogenic KW - Liquid Hydrogen KW - Multi-Layer Insultation KW - Heat Transfer KW - Hydrogen Storage Safety PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-614919 DO - https://doi.org/10.1016/j.jlp.2024.105461 SN - 0950-4230 VL - 92 SP - 1 EP - 7 PB - Elsevier Ltd. AN - OPUS4-61491 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Camplese, Davide A1 - Scarponi, Giordano Emrys A1 - Eberwein, Robert A1 - Hajhariri, Aliasghar A1 - Otremba, Frank A1 - Cozzani, Valerio T1 - Modelling Fire Response of Cryogenic Liquid Hydrogen Tanks Equipped with Multilayer Insulation (MLI) Systems N2 - In the context of the growing global interest in hydrogen-based green energy, cryogenic tanks equipped with multi-layer insulation (MLI) are emerging as a leading solution for storing hydrogen in vehicles. The integrity of these systems might be threatened during fire exposure. This can trigger the degradation of the MLI materials and induce rapid pressurization of the tank with a high risk of catastrophic failure. In this work, a novel lumped model to simulate the thermal response of MLI-equipped cryogenic liquid hydrogen tanks is presented. The model integrates the accurate database “Coolprop” for hydrogen thermodynamic properties and sub-models for detailed simulation of MLI degradation, providing a realistic simulation of the experimental data obtained under normal operating conditions. The application of the model to several case studies considering different numbers of MLI layers and tank geometries demonstrates that aluminum-based MLI offers scarce protection in case of exposure to a hydrocarbon poolfire. T2 - CISAP 11 CY - Neapel, Italy DA - 15.09.2024 KW - LH2 KW - LNG KW - Cryogenic storage tank KW - Insulation KW - MLI PY - 2024 DO - https://doi.org/10.3303/CET24111076 SN - 2283-9216 VL - 111 SP - 451 EP - 456 PB - AIDIC The Italian Association of Chemical Engineering AN - OPUS4-61384 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Eberwein, Robert A1 - Hajhariri, Aliasghar A1 - Camplese, Davide A1 - Scarponi, Giordano Emrys A1 - Cozzani, Valerio A1 - Otremba, Frank ED - Di Benedetto, Almerinda T1 - Experimental Research Of A Tank For A Cryogenic Fluid With A Wall Rupture In A Fire Scenario N2 - In the course of decarbonizing the energy industry, cryogenic energy carriers as liquefied hydrogen (LH2) and liquefied natural gas (LNG) are seen as having great potential. In technical applications, the challenge is to keep these energy carriers cold for a long time. This is achieved in the road transport sector and also stationary applications by thermal super insulations (TSI) which based on double-walled tanks with vacuum and multilayer insulation (MLI) in the interspace. This study focuses on the behaviour of widely used combustible MLI in a fire scenario, at vacuum and atmospheric pressure conditions. The former corresponds to the typical design condition and the latter to the condition after an outer hull rapture of a tank. Furthermore, two fire scenarios were taken into account: a standard-oriented approach and a hydrocarbon fire-oriented approach. For the study, a test rig was applied that allows testing of TSI at industrial conditions and subsequent analysis of TSI samples. The test rig allows thermal loading and performance analysis of TSI samples at the same time. Comparing the tests, the samples degraded differently. However, no sudden failure of the entire MLI was observed in any test. These results are relevant for the evaluation of incidents with tanks for the storage of cryogenic fluids and can thus contribute to the improvement of TSI and the development of emergency measures for the protection of persons and infrastructures. T2 - 15th International Symposium on Hazards, Prevention and Mitigation of Industrial Explosions (ISHPMIE) CY - Neapel, Italy DA - 10.06.2024 KW - Liquefied hydrogen KW - Liquefied natural gas KW - Cryogenic storage tank KW - Fire KW - Thermal insulation KW - Multi-Layer Insulation PY - 2024 SP - 707 EP - 717 AN - OPUS4-60460 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Eberwein, Robert A1 - Hajhariri, Aliasghar A1 - Camplese, Davide A1 - Scarponi, Giordano Emrys A1 - Cozzani, Valerio A1 - Otremba, Frank T1 - A comparative study on insulation materials in tanks for the storage of cryogenic fluids in fire incidents N2 - Liquefied Hydrogen (LH2) or Liquefied Natural Gas (LNG) establish themselves as important energy carriers in the transport sector. Its storage requires tanks with Thermal Super Insulations (TSI) to keep the transported fluid cold. TSI has proven itself in various applications over a long time, but not in the land transport sector, where accidents involving collisions, fires, and their combination are to be expected. The focus of this study is to investigate the behavior of different types of TSI when exposed to a heat source that represents a fire. Therefore, a High-Temperature Thermal Vacuum Chamber (HTTVC) was used that allows the thermal loading of thermal insulation material in a vacuum and measuring the heat flow through the TSI in parallel. Within this study, 5 samples were tested regarding 3 different types of MLI, rock wool, and perlites. The thermal exposure caused different effects on the samples. In practice, this can be connected to the rapid release of flammable gases as well as a Boiling Liquid Expanding Vapour Explosion (BLEVE). These results are relevant for the evaluation of accident scenarios, the improvement of TSI, and the development of emergency measures. T2 - IMECE 2023 CY - New Orleans, Louisiana, USA DA - 29.10.2023 KW - LH2 KW - LNG KW - Fire PY - 2023 SP - 1 EP - 7 AN - OPUS4-58768 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Camplese, Davide A1 - Scarponi, Giordano Emrys A1 - Chianese, Carmela A1 - Hajhariri, Aliasghar A1 - Eberwein, Robert A1 - Otremba, Frank A1 - Cozzani, Valerio T1 - Modeling the performance of multilayer insulation in cryogenic tanks undergoing external fire scenarios N2 - Multilayer Insulation (MLI) is frequently used in vacuum conditions for the thermal insulation of cryogenic storage tanks. The severe consequences of the degradation of such materials in engulfing fire scenarios were recently evidenced by several large-scale experimental tests. In the present study, an innovative modelling approach was developed to assess the performance of heat transfer in polyester-based MLI materials for cryogenic applications under fire conditions. A specific layer-by-layer approach was integrated with an apparent kinetic thermal degradation model based on thermogravimetric analysis results. The modeling results provided a realistic simulation of the experimental data obtained by High-Temperature Thermal Vacuum Chamber tests reproducing fire exposure conditions. The model was then applied to assess the behavior of MLI systems for liquid hydrogen tanks in realistic fire scenarios. The results show that in intense fire scenarios degradation occurs rapidly, compromising the thermal insulation performances of the system within a few minutes. KW - Multilayer Insulation KW - Cryogenic Vessels KW - Liquefied Hydrogen KW - Liquefied Natural Gas KW - Safety KW - Fire PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-599418 DO - https://doi.org/10.1016/j.psep.2024.04.061 SN - 0957-5820 VL - 186 SP - 1169 EP - 1182 PB - Elsevier B.V. AN - OPUS4-59941 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hajhariri, Aliasghar A1 - Eberwein, Robert A1 - Camplese, Davide A1 - Emrys Scarponi, Giordano A1 - Otremba, Frank A1 - Cozzani, Valerio A1 - Seidlitz, Holger T1 - A Comprehensive Numerical Study of the Behaviour of an LH2 Storage Tank in the Event of a Fire N2 - As the world moves towards green energy production, effective storage and transportation solutions become essential. To support this transition, energy carriers with minimal or zero environmental impact are required. Liquified hydrogen represents a promising candidate due to its emissions-neutral properties. However, its highly flammable nature necessitates adherence to strict safety codes and standards. Storing hydrogen often requires advanced super-insulation materials. To enhance the safety of cryogenic hydrogen storage tanks under extreme conditions, such as those encountered during fire accidents, it is crucial to understand the thermal behaviour of the tank. Predicting pressurization and potential failure in advance demands a robust and comprehensive model. However, still such models suffer lack of detailed heat transfer models which account for various sub-processes during an accident scenario. Hence, this study introduces a comprehensive model for the pressurization of cryogenic tanks equipped with multi-layer insulation (MLI) systemsin the event of fire, which comprises several sub-models. These sub-models account for heat transfer phenomena through the thermal insulation at nominal conditions and its thermal degradation during fire exposure, the fluid, the internal pressurization, and the performance of the pressure relief valve. This study provides valuable insights into the safety and the behaviour of hydrogen storage tanks under thermal loads. KW - Heat transfer KW - Multi-Layer Insulation KW - Cryogenic KW - Liquid Hydrogen PY - 2025 DO - https://doi.org/10.3303/CET25116114 VL - 116 SP - 679 EP - 684 PB - AIDIC AN - OPUS4-63813 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hajhariri, Aliasghar A1 - Eberwein, Robert A1 - Camplese, Davide A1 - Scarponi, Giordano Emrys A1 - Cozzani, Valerio A1 - Otremba, Frank A1 - Seidlitz, Holger T1 - Non-combustible MLI based insulation behavior under fire condition - Experimental and numerical investigation N2 - The number of applications that demand zero-emission energy carriers, such as liquified hydrogen (LH2), is increasing worldwide. LH2 is typically transported or stored under cryogenic conditions. Storage in such conditions requires super thermal insulations which maintain very low boil-off for a prolonged time. Multi-Layer insulation (MLI) finds widespread use in cryogenic applications, designed to effectively restrict heat inleak towards cryogenic fluids. However, recent studies evidenced that exposure to high heat fluxes, such as in the event of a fire accident, can cause the thermal degradation of the insulation material, resulting in the severe collapse of its heat resistance performance. Therefore, the risk of rapid tank pressurization and its connection to the risk of BLEVE may be possible. This study proposes a numerical model to assess the performances of aluminum-based MLI materials under fire conditions. The model offers insights into the total heat transfer rate through the insulation, serving as a KW - Multi-Layer Insulation KW - Cryogenic KW - Liquid Hydrogen KW - CFD PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-617780 DO - https://doi.org/10.1016/j.psep.2024.11.037 VL - 193 SP - 603 EP - 620 PB - Elsevier B.V. AN - OPUS4-61778 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Eberwein, Robert A1 - Hajhariri, Aliasghar A1 - Camplese, D. A1 - Scarponi, G. E. A1 - Cozzani, V. A1 - Otremba, Frank T1 - Insulation Materials Used in Tanks for the Storage of Cryogenic Fluids in Fire Scenarios N2 - The importance of tanks for storing cryogenic fluids in the energy industry is increasing because of ongoing political conflicts and the implementation of more environmentally friendly energy sources. Key representatives for the application of cryogenic tanks are natural gas in the form of Liquefied Natural Gas (LNG) and hydrogen, e. g. in the form of Liquefied Hydrogen (LH2), for which significantly higher transport capacities can be achieved with the same transport volume using cryogenic storages than with storages based solely on overpressure. What applies to all cryogenic transported fluids in common is their condition that must be maintained. Hence heat flows into the preserved fluid must be minimized. Thermal super Insulations (TSI) based on e. g. multilayer insulations (MLI), perlites, and vacuum are utilized for this purpose and have already proven themselves in similar applications. However, for the use of tanks for cryogenic fluids in the transport sector, there is insufficient knowledge regarding the course and consequences of incidents, which is due to the still short period of use and the few documented incidents, hence few investigations carried out in this field. Typical scenarios in the transport sector represent car accidents with collisions, fires, and their combination, which are associated with extraordinary loads on the tank. The focus of this study is to investigate the behavior of TSI as a result of their thermal exposure to a heat source representing a fire. It is worth mentioning that this could lead to an increase of the heat flux into a tank by several orders of magnitude, and to permanent damage of the TSI, ultimately rapid release of flammable gas as well as a Boiling Liquide Expanding Vapour Explosion (BLEVE). For this purpose, a high temperature thermal vacuum chamber (HTTVC) has been developed that allows thermal loading of MLI or perlites in a vacuum and simultaneous measurement of heat flow through this TSI. The HTTVC is designed to represent realistic insulation conditions and to withstand thermal loads from typical design fires. The HTTVC was applied to investigate TSI based on MLI and vacuum. It is shown that the thermal stress caused permanent damage to the TSI, with shrinkage, phase change, pyrolysis, and condensation being significant damage mechanisms. The results are relevant for the evaluation of accident scenarios and can thus contribute to the improvement of TSI and the development of emergency measures for the protection of persons and infrastructures. T2 - ASME 2023 Pressure Vessels & Piping Conference (PVP2023) CY - Atlanta, Georgia, USA DA - 16.07.2023 KW - LH2 KW - LNG KW - MLI KW - Fire PY - 2023 SP - 1 EP - 8 PB - ASME AN - OPUS4-57973 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Eberwein, Robert A1 - Scarponi, Giordano Emrys A1 - Cozzani, Valerio A1 - Otremba, Frank T1 - Lh2 Tanks In Fire Incidents - The Cryogenic High Temperature Thermal Vacuum Chamber Enables In-Depth Insights N2 - Liquefied Hydrogen (LH2) and Liquefied Natural Gas (LNG) establish themselves as important energy carriers in the transport sector. Their storage requires tanks with thermal super-insulations to keep them at cryogenic conditions for a long time. These insulation systems have proven itself in various applications over a long time. However, these insulations are still new in land transportation, where accidents involving collisions, fires, and their combination are to be expected. This study summarizes the results of the ongoing research program in which insulations commonly used in industry were analysed through experimental and numerical studies under fire-like conditions. It was found that there are strong differences among the various insulation systems. Several safety concerns and research gaps exists for layered insulations, which are typically used in land transport. To further analyse these insulation systems, a new test concept called Cryogenic High Temperature Thermal Vacuum Chamber (CHTTVC) was developed and manufactured. This concept enables the testing of large insulation samples under industrial conditions and the consideration of cryogenic conditions relevant for the investigation of various phenomena. The results are important for the evaluation of accident scenarios, the improvement of thermal super-insulations, and the development of emergency measures. T2 - IMECE 2024 CY - Oregon, Portland, USA DA - 17.11.2024 KW - LH2 KW - LNG KW - Fire KW - Insulation KW - Safety PY - 2024 SN - 978-0-7918-8869-8 SP - 1 EP - 7 PB - ASME AN - OPUS4-61751 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Camplese, D. A1 - Chianese, C. A1 - Scarponi, G. A1 - Eberwein, Robert A1 - Otremba, Frank A1 - Cozzani, V. T1 - Analysis of high temperature degradation of multi-layer insulation (MLI) systems for liquid hydrogen storage tanks N2 - The interest in hydrogen-based green energy is increasing worldwide, and the same is true for hydrogen-powered vehicles. Among the possible solutions to store hydrogen in such vehicles, cryogenic tanks equipped with multi-layer insulation (MLI) are the most promising to increase the amount of energy stored per unit volume. However, MLI is affected by severe deterioration when exposed to an external source of heat such as a fire following a car accident, leaving the tank unprotected and leading to failure in a relatively short time. In this work, a one-dimensional model to evaluate MLI thermal degradation when a liquid hydrogen tank is exposed to fire is presented. The relevance of taking MLI degradation into account when simulating the pressure increase due to external fire exposure is here demonstrated through the analysis of several case studies. The results show that MLI systems performance depletes within a few minutes of exposure to hydrocarbon poolfire. T2 - ICheaP 16 CY - Naples, Italy DA - 21.05.2023 KW - LH2 KW - MLI KW - Tiefkalt KW - Fire KW - Tank PY - 2023 SN - 2283-9216 VL - 2023 SP - 1 EP - 6 PB - AIDIC Servizi S.r.l. AN - OPUS4-57584 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Camplese, Davide A1 - Scarponi, Giordano Emrys A1 - Eberwein, Robert A1 - Hajhariri, Aliasghar A1 - Otremba, Frank A1 - Cozzani, Valerio T1 - Comparative performance assessment of multilayer insulation (MLI) systems for liquid hydrogen vessels in fire scenarios N2 - Multilayer Insulation (MLI) systems are a mature technology for cryogenic liquid hydrogen (LH2) tank thermal insulation. Recent tests evidenced that MLI materials may be damaged when exposed to fire, resulting in critical safety issues in the case of accidents. Thus, an innovative approach to the performance assessment of aluminum and polyester-based MLIs for LH2 tanks in fire scenarios was developed. A specific model integrating the hightemperature degradation of MLIs and the thermodynamic modeling of the tank lading was coupled to specific key performance indicators. Results of the analysis applied to a vehicle-scale tank equipped with 80 MLI layers indicate that MLI degradation and consequent tank failure may occur in less than 20 min for external shell temperatures above 1160 K in the presence of full engulfment, regardless of insulation used. Conversely, degradation does not occur earlier than 3600s below 603 and 928 K for polyester and aluminum-based MLI, respectively. KW - LH2 KW - LNG KW - Cryogenic storage tank KW - Fire KW - Insulation PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-630841 DO - https://doi.org/10.1016/j.ijhydene.2025.04.534 SN - 0360-3199 VL - 135 SP - 537 EP - 552 PB - Elsevier Ltd. AN - OPUS4-63084 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -