TY - CONF A1 - Jann, Oliver A1 - Wilke, Olaf T1 - Comparison of FLEC with other climate chambers, Gemeran experiences T2 - Proceedings of the 2nd International FLEC Symposium T2 - 2nd International FLEC Symposium CY - Copenhagen, Denmark DA - 2001-09-06 PY - 2001 SP - 18 EP - 27 AN - OPUS4-7204 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wiegner, Katharina A1 - Horn, Wolfgang A1 - Wilke, Olaf A1 - Kalus, Sabine A1 - Jann, Oliver T1 - Different possibilities for the statistical evaluation of round robin tests for volatile organic compounds in emission test chambers T2 - Healthy Buildings 2012 - 10th International conference (Proceedings) T2 - Healthy Buildings 2012 - 10th International conference CY - Brisbane, Australia DA - 2012-07-08 KW - Reference material KW - Round robin test KW - Emission test chamber KW - VOC-emission KW - Product emission testing PY - 2012 SN - 978-1-921897-40-5 SP - 1 EP - 2 (8B.6) AN - OPUS4-27526 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Wilke, Olaf A1 - Kirchner, D. A1 - Jann, Oliver A1 - Kemmlein, S. A1 - Kalus, Sabine A1 - Süßmilch, C. T1 - European interlaboratory study for sampling VOC emissions - Step 1 - Liquid samples added on Tenax tubes T2 - Indoor Air 2008, 11th International Conference on Indoor Air Quality and Climate, August 17-22, 2008, Copenhagen, Denmark (Proceedings) T2 - Indoor Air 2008, 11th International Conference on Indoor Air Quality and Climate CY - Copenhagen, Denmark DA - 2008-08-17 KW - ISO 16000-6 KW - VOC analysis KW - Interlaboratory study KW - Emission tests KW - Building material PY - 2008 IS - Paper 226 SP - 1 AN - OPUS4-18048 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Kalus, Sabine A1 - Brödner, Doris A1 - Juritsch, Elevtheria A1 - Süßmilch, C. A1 - Kirchner, D. T1 - European interlaboratory study for sampling VOC emissions - Step 2 - Sampling with Tenax tubes at an emission test chamber T2 - Indoor Air 2008, 11th International Conference on Indoor Air Quality and Climate, August 17-22, 2008, Copenhagen, Denmark (Proceedings) T2 - Indoor Air 2008, August 17-22, 2008 CY - Copenhagen, Denmark DA - 2008-08-17 KW - VOC KW - Tenax thermal desorption KW - Emission test chamber KW - Proficiency testing KW - Interlaboratory study PY - 2008 IS - Paper ID: 238 SP - 1 AN - OPUS4-17864 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Richter, Matthias A1 - Wilke, Olaf A1 - Jann, Oliver T1 - Use of emission test chambers for the determination of chemical emissions from construction materials T2 - 1st International conference on the chemistry of construction materials (Proceedings) T2 - 1st International conference on the chemistry of construction materials CY - Berlin, Germany DA - 2013-10-07 KW - VOC KW - Emission from materials KW - Construction materials KW - Emission test chamber PY - 2013 SN - 978-3-936028-75-1 N1 - Serientitel: GDCh-Monographien – Series title: GDCh-Monographien VL - 46 SP - 259 EP - 262 AN - OPUS4-29480 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pech, Anja A1 - Wilke, Olaf A1 - Horn, Wolfgang A1 - Jann, Oliver T1 - Analysis of very volatile organic compounds (VVOC) with thermal desorption GC-MS T2 - Proceedings of Indoor Air 2016, The 14th international conference of Indoor Air Quality and Climate N2 - Most VVOC were rarely considered in the evaluation of construction products. (Salthammer, 2014) In Germany this will change because the latest version of the German AgBB scheme for health evaluation (2015) now include VVOC, e.g. ethyl acetate and ethanol. In this study selected compounds were tested with the procedure described in ISO 16017 and a method for measuring VVOC with thermal desorption was developed. Three different adsorbents Tenax TA, Carbograph 5TD and Carbopack X were tested to analyse VVOC according to ISO 16017. For the tested VVOC, Carbograph 5TD showed the best results under the chosen analytical conditions. T2 - Indoor Air 2016, The 14th international conference of Indoor Air Quality and Climate CY - Gent, Belgium DA - 03.07.2016 KW - Thermal desorption KW - VVOC KW - Carbograph 5TD KW - Carbopack X PY - 2016 SP - Paper 889, 1 EP - 2 AN - OPUS4-37035 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Wilke, Olaf A1 - Wiegner, Katharina A1 - Jann, Oliver A1 - Kalus, Sabine A1 - Till, Carola T1 - Interlaboratory study with Tenax thermal desorption - Phase 1 - liquid samples added onto tenax tubes T2 - Healthy buildings 2009 - 9th International conference & exhibition (Proceedings) T2 - Healthy buildings 2009 - 9th International conference & exhibition CY - Syracuse, NY, USA DA - 2009-09-13 KW - ISO 16000-6 KW - Interlaboratory study KW - VOC KW - External quality management system PY - 2009 IS - Paper 355 SP - 1 EP - 2 CY - Syracuse, NY, USA AN - OPUS4-19923 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wiegner, Katharina A1 - Wilke, Olaf A1 - Jann, Oliver A1 - Brödner, Doris A1 - Scheffer, Harald A1 - Kalus, Sabine A1 - Till, Carola T1 - Study on VOC-Emissions from Oriented Strand Boards (OSB) T2 - Healthy buildings 2009 - 9th International conference & exhibition (Proceedings) T2 - Healthy buildings 2009 - 9th International conference & exhibition CY - Syracuse, NY, USA DA - 2009-09-13 KW - Volatile organic compound (VOC) KW - Aldehyde KW - Antioxidant KW - Wood KW - Oriented strand boards (OSB) PY - 2009 IS - Paper 247 SP - 1 EP - 4 CY - Syracuse, NY, USA AN - OPUS4-19928 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Kalus, Sabine A1 - Brödner, Doris A1 - Juritsch, Elevtheria A1 - Till, Carola A1 - Kirchner, D. T1 - European interlaboratory study for sampling VOC emissions - Step 3 - Emission test chamber measurements T2 - Healthy buildings 2009 - 9th International conference & exhibition (Proceedings) T2 - Healthy buildings 2009 - 9th International conference & exhibition CY - Syracuse, NY, USA DA - 2009-09-13 KW - VOC emission KW - Emission test chamber KW - Round robin test KW - Construction products KW - Tenax thermal desorption PY - 2009 IS - Paper 343 SP - 1 EP - 4 CY - Syracuse, NY, USA AN - OPUS4-20093 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Pech, Anja A1 - Mull, Birte A1 - Horn, Wolfgang A1 - Jann, Oliver T1 - Determination of methanol and ethanol in test chamber air by using TDS-GC-FID T2 - Indoor Air 2014 - 13th International conference on indoor air quality and climate (Proceedings) N2 - A method for the determination of very volatile organic compounds (VVOC) in air was developed and successfully tested for methanol and ethanol. Carbotrap 300 (R) (a multi-bed tube using Carbopack C (R), Carbopack B (R) and Carbosive SIII (R)) was selected as sorption material for thermal desorption and tested for its suitability for emission test chamber measurements. The adsorption behaviour and the chromatographic results are influenced negatively by spiking aqueous solutions on the adsorption medium for calibration purposes. The latter effect can be reduced by blowing dry air across the adsorbent to remove the adsorbed water. Detection and quantification limits were determined for a GC-FID system and compared to GC-MS. The applicability of the method was tested with a methanol eliminating silane modified polymeric adhesive (SMP-adhesive for parquet) in an emission test chamber. T2 - Indoor Air 2014 - 13th International conference on indoor air quality and climate CY - Hong Kong, People's Republic of China DA - 07.07.2014 KW - Methanol KW - Ethanol KW - VVOC KW - Thermal desorption KW - Carbotrap 300 PY - 2014 SP - B6-HP0620, 1-2 AN - OPUS4-32323 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Richter, Janine A1 - Wilke, Olaf A1 - Jann, Oliver T1 - Emissions of formaldehyde and VOC from wood-based building products T2 - Proceedings of Healthy Buildings 2017 Europe N2 - Wood-based materials are well-known sources for formaldehyde emission in the indoor environment. Different testing standards lead to different emission values for the materials. Such standards are compared in this study. Besides scenarios with varying loading factors, air exchange rates and climatic conditions were investigated to evaluate the formaldehyde emission potential of different building products. Under realistic indoor conditions used for the emission chamber tests, exceeding of formaldehyde indoor guide values were obtained. Results showed the need for improvement of wood-based materials with lower formaldehyde emissions and the adaption of testing parameters closer to realistic conditions. T2 - Healthy Buildings 2017 Europe CY - Lublin, Poland DA - 02.07.2017 KW - Formaldehyde KW - Emission chamber testing KW - Particle board KW - OSB PY - 2017 SN - 978-83-7947-232-1 SP - Paper 0175, 1-6 AN - OPUS4-41575 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Jann, Oliver T1 - Emissions of very volitale organic compounds (VVOC) from particle boards T2 - Proceedings of the 14th international conference of Indoor Air Quality and Climate, Indoor Air 2016 N2 - The latest version of the German AgBB evaluation scheme (2015) for construction products includes some VVOC, e.g. formaldehyde, acetaldehyde and acetone. For these VVOC so-called LCI values (lowest concentration of interest) were derived which are used for the calculation of the so-called R-value (risk index, see reference 1 for the calculation). Test chamber measurements of particle boards show that the emissions of VVOC might have significant impact on the R-value and therefore for the health evaluation. T2 - The 14th international conference of Indoor Air Quality and Climate, Indoor Air 2016 CY - Gent, Belgium DA - 03.07.2016 KW - Formaldehyde KW - AgBB evaluation scheme KW - Particle board KW - OSB KW - VVOC KW - Emission test chamber PY - 2016 SP - Paper 965, 1 AN - OPUS4-37030 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Richter, Janine A1 - Jann, Oliver A1 - Wilke, Olaf T1 - Emissions of formaldehyde from acoustic tiles T2 - Proceedings of Healthy Buildings 2017 Europe N2 - Acoustics is an important aspect for large rooms especially in schools, kindergartens and offices. Foam tiles made from melamine resins are often used for acoustic insulation because they show good fire resistance and good thermal insulation properties. But they can emit formaldehyde. In Germany there are cases with a resulting indoor air concentration of higher than 100 µg/m³. In this study samples from two schools and one office were investigated. Additionally, new tiles were purchased and tested to evaluate the general potential as formaldehyde source. T2 - Healthy Buildings 2017 Europe CY - Lublin, Poland DA - 02.07.2014 KW - Building product KW - Emission test chamber KW - Formaldehyde KW - Foam tiles PY - 2017 SN - 978-83-7947-232-1 SP - Paper 0176, 1-2 AN - OPUS4-41574 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Jann, Oliver T1 - Comparison of Formaldehyde Concentrations in Emission Test Chambers Using EN 717-1 and EN 16516 T2 - Proceedings of Indoor Air Conference 2018 N2 - For more than 25 years EN 717-1 (Wood-based panels - Determination of formaldehyde re-lease - Part 1: Formaldehyde emission by the chamber method) is the standard for formalde-hyde emission testing of wooden boards. In 2017 EN 16516 (Construction products - Assess-ment of release of dangerous substances - Determination of emissions into indoor air) was published as a new harmonised standard for the emission testing of construction products. Because test chamber conditions are different, both standards give different concentrations for formaldehyde. To determine a conversion factor four test series were set up with different wooden boards. For a loading of 1 m²/m³ the conversion factor is 1.6. This means that the formaldehyde concentration measured under the conditions of EN 16516 is a factor of 1.6 higher compared to EN 717-1. T2 - Conference on Indoor Air CY - Philadelphia, PA, USA DA - 22.07.2018 KW - Loading factor KW - European standard KW - Construction products KW - Air exchange rate PY - 2018 SP - paper 627 AN - OPUS4-45630 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Wiegner, Katharina A1 - Wilke, Olaf A1 - Jann, Oliver T1 - Method validation study for VOC emission measurements T2 - Indoor Air 2011, 12th International conference on indoor air quality and climate (Proceedings) N2 - Quality and trueness of results received from measurements are very important for all involved parties, producers and consumers as well; for instance, if the results were used for acceptance of a product within a labeling procedure. Based on an inter-laboratory study with many German, European and US-American laboratories an extemal quality assurance System for the analysis of VOC emitting from products or the measurement in indoor air should be implemented (financed by the German Federal Environmental Agency). A focus was set on the emission test chamber experiments and the connected analytical procedure. VOC have a dominating influence when applying the German AgBB scheme for health evaluation of building products. Therefore it is necessary to ensure that the results between the testing laboratories are comparable. The successful participation to such round robin tests is offen essential for the acceptance of results given by an analytical laboratory. T2 - Indoor Air 2011, 12th International conference on indoor air quality and climate CY - Austin, TX, USA DA - 05.06.2011 KW - Round robin test KW - VOC KW - Construction product KW - Emission PY - 2011 IS - Paper 768 SP - 1 EP - 2 AN - OPUS4-23880 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Horn, Wolfgang A1 - Wiegner, Katharina A1 - Jann, Oliver A1 - Kalus, Sabine A1 - Till, Carola T1 - Interlaboratory study with Tenax thermal desorption - Phase 2 - Tenax tubes spiked by BAM T2 - Healthy buildings 2009 - 9th International conference & exhibition (Proceedings) T2 - Healthy buildings 2009 - 9th International conference & exhibition CY - Syracuse, NY, USA DA - 2009-09-13 KW - ISO 16000-6 KW - Interlaboratory study KW - VOC KW - External quality management system PY - 2009 IS - Paper 345 SP - 1 EP - 2 CY - Syracuse, NY, USA AN - OPUS4-20094 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Seeger, Stefan A1 - Bresch, Harald A1 - Brödner, Doris A1 - Juritsch, Elevtheria A1 - Jann, Oliver T1 - Sampling and characterisation of ultra fine particles released from laser printers T2 - Indoor Air 2008, 11th International Conference on Indoor Air Quality and Climate, August 17-22, 2008, Copenhagen, Denmark (Proceedings) T2 - Indoor Air 2008, August 17-22, 2008 CY - Copenhagen, Denmark DA - 2008-08-17 KW - Aerosol KW - Ultra fine particle KW - Laser printer KW - Cyclosiloxanes PY - 2008 IS - Paper ID: 239 SP - 1 AN - OPUS4-17865 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -