TY - CONF A1 - Wilke, Olaf A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Kalus, Sabine A1 - Brödner, Doris A1 - Juritsch, Elevtheria A1 - Süßmilch, C. A1 - Kirchner, D. T1 - European interlaboratory study for sampling VOC emissions - Step 2 - Sampling with Tenax tubes at an emission test chamber T2 - Indoor Air 2008, August 17-22, 2008 CY - Copenhagen, Denmark DA - 2008-08-17 KW - VOC KW - Tenax thermal desorption KW - Emission test chamber KW - Proficiency testing KW - Interlaboratory study PY - 2008 IS - Paper ID: 238 SP - 1 AN - OPUS4-17864 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wilke, Olaf A1 - Jann, Oliver A1 - Brödner, Doris T1 - Fast and reliable determination of emissions from carpet adhesives PY - 2005 UR - http://www.gerstel.com/magazine_solution_05.htm SN - 1619-0076 IS - 5 SP - 4 EP - 5 CY - Mülheim an der Ruhr AN - OPUS4-7323 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Richter, Matthias A1 - Wilke, Olaf A1 - Jann, Oliver T1 - Use of emission test chambers for the determination of chemical emissions from construction materials T2 - 1st International conference on the chemistry of construction materials CY - Berlin, Germany DA - 2013-10-07 KW - VOC KW - Emission from materials KW - Construction materials KW - Emission test chamber PY - 2013 SN - 978-3-936028-75-1 N1 - Serientitel: GDCh-Monographien – Series title: GDCh-Monographien VL - 46 SP - 259 EP - 262 AN - OPUS4-29480 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pech, Anja A1 - Wilke, Olaf A1 - Horn, Wolfgang A1 - Jann, Oliver T1 - Analysis of very volatile organic compounds (VVOC) with thermal desorption GC-MS N2 - Most VVOC were rarely considered in the evaluation of construction products. (Salthammer, 2014) In Germany this will change because the latest version of the German AgBB scheme for health evaluation (2015) now include VVOC, e.g. ethyl acetate and ethanol. In this study selected compounds were tested with the procedure described in ISO 16017 and a method for measuring VVOC with thermal desorption was developed. Three different adsorbents Tenax TA, Carbograph 5TD and Carbopack X were tested to analyse VVOC according to ISO 16017. For the tested VVOC, Carbograph 5TD showed the best results under the chosen analytical conditions. T2 - Indoor Air 2016, The 14th international conference of Indoor Air Quality and Climate CY - Gent, Belgium DA - 03.07.2016 KW - Thermal desorption KW - VVOC KW - Carbograph 5TD KW - Carbopack X PY - 2016 SP - Paper 889, 1 EP - 2 AN - OPUS4-37035 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Wilke, Olaf A1 - Wiegner, Katharina A1 - Jann, Oliver A1 - Kalus, Sabine A1 - Till, Carola T1 - Interlaboratory study with Tenax thermal desorption - Phase 1 - liquid samples added onto tenax tubes T2 - Healthy buildings 2009 - 9th International conference & exhibition CY - Syracuse, NY, USA DA - 2009-09-13 KW - ISO 16000-6 KW - Interlaboratory study KW - VOC KW - External quality management system PY - 2009 IS - Paper 355 SP - 1 EP - 2 CY - Syracuse, NY, USA AN - OPUS4-19923 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wiegner, Katharina A1 - Wilke, Olaf A1 - Jann, Oliver A1 - Brödner, Doris A1 - Scheffer, Harald A1 - Kalus, Sabine A1 - Till, Carola T1 - Study on VOC-Emissions from Oriented Strand Boards (OSB) T2 - Healthy buildings 2009 - 9th International conference & exhibition CY - Syracuse, NY, USA DA - 2009-09-13 KW - Volatile organic compound (VOC) KW - Aldehyde KW - Antioxidant KW - Wood KW - Oriented strand boards (OSB) PY - 2009 IS - Paper 247 SP - 1 EP - 4 CY - Syracuse, NY, USA AN - OPUS4-19928 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Kalus, Sabine A1 - Brödner, Doris A1 - Juritsch, Elevtheria A1 - Till, Carola A1 - Kirchner, D. T1 - European interlaboratory study for sampling VOC emissions - Step 3 - Emission test chamber measurements T2 - Healthy buildings 2009 - 9th International conference & exhibition CY - Syracuse, NY, USA DA - 2009-09-13 KW - VOC emission KW - Emission test chamber KW - Round robin test KW - Construction products KW - Tenax thermal desorption PY - 2009 IS - Paper 343 SP - 1 EP - 4 CY - Syracuse, NY, USA AN - OPUS4-20093 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Richter, Janine A1 - Wilke, Olaf A1 - Jann, Oliver T1 - Emissions of formaldehyde and VOC from wood-based building products N2 - Wood-based materials are well-known sources for formaldehyde emission in the indoor environment. Different testing standards lead to different emission values for the materials. Such standards are compared in this study. Besides scenarios with varying loading factors, air exchange rates and climatic conditions were investigated to evaluate the formaldehyde emission potential of different building products. Under realistic indoor conditions used for the emission chamber tests, exceeding of formaldehyde indoor guide values were obtained. Results showed the need for improvement of wood-based materials with lower formaldehyde emissions and the adaption of testing parameters closer to realistic conditions. T2 - Healthy Buildings 2017 Europe CY - Lublin, Poland DA - 02.07.2017 KW - Formaldehyde KW - Emission chamber testing KW - Particle board KW - OSB PY - 2017 SN - 978-83-7947-232-1 SP - Paper 0175, 1-6 AN - OPUS4-41575 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Jann, Oliver T1 - Emissions of very volitale organic compounds (VVOC) from particle boards N2 - The latest version of the German AgBB evaluation scheme (2015) for construction products includes some VVOC, e.g. formaldehyde, acetaldehyde and acetone. For these VVOC so-called LCI values (lowest concentration of interest) were derived which are used for the calculation of the so-called R-value (risk index, see reference 1 for the calculation). Test chamber measurements of particle boards show that the emissions of VVOC might have significant impact on the R-value and therefore for the health evaluation. T2 - The 14th international conference of Indoor Air Quality and Climate, Indoor Air 2016 CY - Gent, Belgium DA - 03.07.2016 KW - Formaldehyde KW - AgBB evaluation scheme KW - Particle board KW - OSB KW - VVOC KW - Emission test chamber PY - 2016 SP - Paper 965, 1 AN - OPUS4-37030 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Richter, Janine A1 - Jann, Oliver A1 - Wilke, Olaf T1 - Emissions of formaldehyde from acoustic tiles N2 - Acoustics is an important aspect for large rooms especially in schools, kindergartens and offices. Foam tiles made from melamine resins are often used for acoustic insulation because they show good fire resistance and good thermal insulation properties. But they can emit formaldehyde. In Germany there are cases with a resulting indoor air concentration of higher than 100 µg/m³. In this study samples from two schools and one office were investigated. Additionally, new tiles were purchased and tested to evaluate the general potential as formaldehyde source. T2 - Healthy Buildings 2017 Europe CY - Lublin, Poland DA - 02.07.2014 KW - Building product KW - Emission test chamber KW - Formaldehyde KW - Foam tiles PY - 2017 SN - 978-83-7947-232-1 SP - Paper 0176, 1-2 AN - OPUS4-41574 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Jann, Oliver T1 - Comparison of Formaldehyde Concentrations in Emission Test Chambers Using EN 717-1 and EN 16516 N2 - For more than 25 years EN 717-1 (Wood-based panels - Determination of formaldehyde re-lease - Part 1: Formaldehyde emission by the chamber method) is the standard for formalde-hyde emission testing of wooden boards. In 2017 EN 16516 (Construction products - Assess-ment of release of dangerous substances - Determination of emissions into indoor air) was published as a new harmonised standard for the emission testing of construction products. Because test chamber conditions are different, both standards give different concentrations for formaldehyde. To determine a conversion factor four test series were set up with different wooden boards. For a loading of 1 m²/m³ the conversion factor is 1.6. This means that the formaldehyde concentration measured under the conditions of EN 16516 is a factor of 1.6 higher compared to EN 717-1. T2 - Conference on Indoor Air CY - Philadelphia, PA, USA DA - 22.07.2018 KW - Loading factor KW - European standard KW - Construction products KW - Air exchange rate PY - 2018 SP - paper 627 AN - OPUS4-45630 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Wilke, Olaf T1 - Suitability of small environmental chambers to test the emission of biocides from treated materials into the air N2 - Biocides are used to protect materials that might be damaged by fungal, microbial or insect activity. The aim of this study is to develop a method for the measurement of these organic compounds, which generally have low or moderate vapor pressures. The biocides considered in this study are permethrin, dichlofluanid, tolylfluanid, iodpropinylbutylcarbamat, octylisothiazolinone, tebuconazole and propiconazole. The emission from two commercial products (plastic foil, wool carpet) containing biocides and of seven types of biocidal formulations applied to wood or clay tiles were investigated in 20-l glass emission test chambers. Each chamber test was performed over a period of 100–200 days, and one investigation was conducted over several years. Compared to volatile organic compounds, low-volatility compounds show totally different emission curves in chamber tests; maximal emission values may be reached in days or weeks. A period of 3 months is sometimes necessary for the determination of area-specific emission rates (SERa's). The SERa's (?g m-2 h-1) from biocide-containing products were determined for permethrin (0.006), propiconazole (0.3), dichlofluanid (2.0), tolylfluanid (1.0), octylisothiazolinone (2.5) and iodpropinylbutylcarbamat (2). In most cases, the SERa stayed at its maximum value or declined slowly over the test period. Additionally, a chamber test begun in 1994 with a piece of wood treated with a typical mixture of biocides dissolved in a technical solvent was continued. SERa's (?g m-2 h-1) for dichlofluanid (0.20), tebuconazole (0.49) and permethrin (0.08) remained detectable after the period of nearly 9 years during which the sample remained continuously in the chamber. This test proved the very slow decrease of emission of low-volatility compounds like permethrin and tebuconazole. KW - Indoor air KW - Biocides KW - Emission test chamber KW - SVOC PY - 2003 DO - https://doi.org/10.1016/j.atmosenv.2003.09.024 SN - 0004-6981 SN - 1352-2310 VL - 37 IS - 39-40 SP - 5477 EP - 5483 PB - Elsevier CY - Amsterdam AN - OPUS4-2676 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Burbiel, M. A1 - Wilke, Olaf A1 - Kalus, Sabine ED - Levin, H. T1 - Biocide emissions from materials into indoor air N2 - The European biocides directive (98/8/EG) demand the control of emissions into the envi-ronment like soil, water and air. In this study a method for measuring the input of biocides into the indoor air from materials should be developed. The emission of two products containing biocides (plastic foil, wool carpet) and six different types of biocide containing formulations applied on wood or ceramic tiles were investigated in 20 or 23 l glass emission chambers. Each chamber test was performed over a period of 100 up to 200 days. SVOC show totally different emission curves in chamber tests compared to volatile organic com-pounds (VOC). They reach their maximum value after some days or weeks. Thus a period of 3 months is sometimes necessary for exact measurements. Area specific emission rates (SERa in µg/m²h) for permethrin (0.006), propiconazole (0.2), dichlofluanid (1.5), tolylfluanid (1.2), octylisothiazolinone (2.5) and for iodpropinylbutyl-carbamat (1.7) were determined. T2 - 9th International Conference on Indoor Air Quality and Climate CY - Monterey, CA, USA DA - 2002-06-30 KW - SVOC KW - Biocide KW - Chamber test KW - Polyurethane foam KW - Testing method PY - 2002 UR - http://www.irbnet.de/daten/iconda/CIB6909.pdf SN - 0-9721832-0-5 VL - 2 SP - 926 EP - 930 PB - International Academy of Indoor Air Sciences CY - Santa Cruz, Calif. AN - OPUS4-2000 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Wilke, Olaf A1 - Jann, Oliver A1 - Brödner, Doris ED - Levin, H. T1 - VOC- and SVOC-Emissions from Adhesives, Floor Coverings and Complete Floor Structures N2 - VOC/SVOC-Emissions from materials for flooring installation (primer, screed, adhesive, floor covering) were measured by means of emission test chambers and cells over a time period of at least 28 days at 23 C, 50 % relative humidity and an area specific air flow rate of q = 1.25 m³/m²h. Single components were tested in comparison to three complete structures (same concrete, primer, screed, adhesive) with different types of floor covering (PVC, carpet, linoleum). Sorption into concrete/screed and different sealing by the flooring materials affected the emissions from the complete structures. The complete structures with linoleum and PVC showed the same emissions and emission rates as the flooring materials alone. Emissions from the carpet-covered structure resulted mainly from the lower layers. For two adhesives the formation of secondary emissions (aldehydes and organic acids) was observed starting after the standard testing time of 28 days. T2 - 9th International Conference on Indoor Air Quality and Climate CY - Monterey, CA, USA DA - 2002-06-30 KW - Test chambers KW - VOCs and SVOCs KW - Secondary emissions KW - Construction and renovation PY - 2002 UR - https://www.irbnet.de/daten/iconda/CIB6472.pdf SN - 0-9721832-0-5 VL - 1 SP - 962 EP - 967 PB - International Academy of Indoor Air Sciences CY - Santa Cruz, Calif. AN - OPUS4-2002 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Rockstroh, Jens A1 - Jann, Oliver A1 - Wilke, Olaf A1 - Noske, Reinhard A1 - Brödner, Doris A1 - Schneider, Uwe A1 - Horn, Wolfgang ED - Wai, T. K. ED - Sekhar, C. ED - Cheong, D. T1 - Investigations on VOC, ozone and dust emissions from hardcopy devices (laser printers, copiers and multifunctional devices) in test chambers - development of a test method T2 - 7th Healthy Buildings Conference ; HB 2003 ; ISIAQ international conference CY - Singapore, Republic of Singapore DA - 2003-12-07 KW - Emissions KW - Printers KW - Copiers KW - VOC KW - Dust KW - Ozone KW - Blue Angel PY - 2003 SN - 981-049974-4 VL - 1 SP - 397 EP - 403 CY - Singapore AN - OPUS4-3315 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Wilke, Olaf A1 - Jann, Oliver A1 - Brödner, Doris ED - Wai, T. K. ED - Sekhar, C. ED - Cheong, D. T1 - VOC and SVOC Contribution of Papers for Hardcopy Devices to Indoor Air Pollution T2 - 7th Healthy Buildings Conference ; HB 2003 ; ISIAQ international conference CY - Singapore, Republic of Singapore DA - 2003-12-07 PY - 2003 SN - 981-049974-4 VL - 1 SP - 289 EP - 295 CY - Singapore AN - OPUS4-3377 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Jann, Oliver A1 - Wilke, Olaf A1 - Brödner, Doris A1 - Plehn, W. ED - Säteri, O. T1 - Eco-Label for low emission wood products and wood base products (RAL-UZ-38) - Part 2: Test procedure and results T2 - Healthy Buildings 2000 Conference CY - Espoo, Finland DA - 2000-08-06 PY - 2000 SN - 952-5236-06-4 VL - 4 SP - 525 EP - 530 PB - SIY Indoor Air Information CY - Helsinki AN - OPUS4-7205 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Wilke, Olaf A1 - Jann, Oliver A1 - Brödner, Doris ED - Säteri, O. T1 - Investigations on the emission behavior of low-emitting adhesives for flooring materials T2 - Healthy Buildings 2000 Conference CY - Espoo, Finland DA - 2000-08-06 PY - 2000 SN - 952-5236-06-4 VL - 4 SP - 391 EP - 396 PB - SIY Indoor Air Information CY - Helsinki AN - OPUS4-7207 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Wilke, Olaf A1 - Jann, Oliver A1 - Brödner, Doris A1 - Rother, Ingrid T1 - Comparison of different types of emission test chambers and cells regarding VOC- and SVOC-emission T2 - Indoor Air 2005 CY - Beijing, PR China DA - 2005-09-04 KW - Emission KW - Chamber KW - Cell KW - Building product KW - VOC KW - SVOC PY - 2005 SN - 7-89494-830-6 IS - 2 SP - 6 pages PB - Tsinghua University Press CY - Beijing AN - OPUS4-11075 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Jann, Oliver A1 - Rockstroh, Jens A1 - Wilke, Olaf T1 - Influence of emissions from hardcopy devices to indoor air quality T2 - Indoor Air 2005 CY - Beijing, PR China DA - 2005-09-04 KW - VOC KW - TVOC KW - Dust KW - Ozone KW - Hardcopy devices PY - 2005 SN - 7-89494-830-6 IS - 2 SP - 6 pages PB - Tsinghua University Press CY - Beijing AN - OPUS4-11074 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Seeger, Stefan A1 - Wilke, Olaf A1 - Bücker, Michael A1 - Jann, Oliver T1 - Time- and Size-Resolved Characterization of Particle Emissions from Office Machines with Printing Function T2 - Healthy Buildings 2006 CY - Lisboa, Portugal DA - 2006-06-04 KW - Hard copy devices KW - Laserprinters KW - Toner KW - Particle emissions KW - Particles KW - Aerosols PY - 2006 SN - 978-989-95067-1-8 VL - 2 SP - 447 EP - 450 CY - Lissabon AN - OPUS4-14522 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Wiegner, Katharina A1 - Wilke, Olaf A1 - Jann, Oliver T1 - Method validation study for VOC emission measurements N2 - Quality and trueness of results received from measurements are very important for all involved parties, producers and consumers as well; for instance, if the results were used for acceptance of a product within a labeling procedure. Based on an inter-laboratory study with many German, European and US-American laboratories an extemal quality assurance System for the analysis of VOC emitting from products or the measurement in indoor air should be implemented (financed by the German Federal Environmental Agency). A focus was set on the emission test chamber experiments and the connected analytical procedure. VOC have a dominating influence when applying the German AgBB scheme for health evaluation of building products. Therefore it is necessary to ensure that the results between the testing laboratories are comparable. The successful participation to such round robin tests is offen essential for the acceptance of results given by an analytical laboratory. T2 - Indoor Air 2011, 12th International conference on indoor air quality and climate CY - Austin, TX, USA DA - 05.06.2011 KW - Round robin test KW - VOC KW - Construction product KW - Emission PY - 2011 IS - Paper 768 SP - 1 EP - 2 AN - OPUS4-23880 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Horn, Wolfgang A1 - Wiegner, Katharina A1 - Jann, Oliver A1 - Kalus, Sabine A1 - Till, Carola T1 - Interlaboratory study with Tenax thermal desorption - Phase 2 - Tenax tubes spiked by BAM T2 - Healthy buildings 2009 - 9th International conference & exhibition CY - Syracuse, NY, USA DA - 2009-09-13 KW - ISO 16000-6 KW - Interlaboratory study KW - VOC KW - External quality management system PY - 2009 IS - Paper 345 SP - 1 EP - 2 CY - Syracuse, NY, USA AN - OPUS4-20094 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Seeger, Stefan A1 - Bresch, Harald A1 - Brödner, Doris A1 - Juritsch, Elevtheria A1 - Jann, Oliver T1 - Sampling and characterisation of ultra fine particles released from laser printers T2 - Indoor Air 2008, August 17-22, 2008 CY - Copenhagen, Denmark DA - 2008-08-17 KW - Aerosol KW - Ultra fine particle KW - Laser printer KW - Cyclosiloxanes PY - 2008 IS - Paper ID: 239 SP - 1 AN - OPUS4-17865 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -