TY - RPRT A1 - Barthel, Mathias A1 - Seeger, Stefan A1 - Rothhardt, Monika A1 - Wilke, Olaf A1 - Horn, Wolfgang A1 - Juritsch, Elevtheria A1 - Hahn, Oliver A1 - Jann, Oliver T1 - Measurement of fine and ultrafine particles from office devices during printing in order to develop a test method for the Blue Angel ecolabel for office-based printing devices T2 - UBA-Texte KW - Bürogeräte KW - Laserdrucker KW - Partikelemissionen PY - 2013 UR - http://www.umweltbundesamt.de/publikationen/measurement-of-fine-ultrafine-particles-from-office SN - 1862-4804 VL - 75 IS - UBA-FBNr: 001743/E / FKZ: 3708 95 301 SP - 1-142, Suppl.RAL-UZ-122 1-39 PB - Umweltbundesamt CY - Dessau-Roßlau AN - OPUS4-28987 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Hahn, Oliver A1 - Wilke, Olaf A1 - Jann, Oliver T1 - Characterization of air quality in museum show cases T2 - Indoor Air 2005 N2 - The present study comprises the characterisation of museum show cases concerning their hazardous potential for art objects. In order to estimate potential risks of damage the emission of volatile organic compounds coming from several construction materials is monitored and different air exchange rates from exhibit cases are determined. For the determination of the VOCs different methods were applied. The first step is a direct thermal extraction of the materials followed by emission test chamber measurements. The tracer gas method with N2O that is used in this study is a convenient procedure to investigate air exchange rates under working conditions greater than 0.05 d-1. The results of this study confirm the importance of the careful choice concerning building materials for show cases. Furthermore the analyses clarify that certain organic compounds might be a problem for the exhibits in show cases with low air exchange rates. T2 - Indoor Air 2005 CY - Beijing, PR China DA - 2005-09-04 KW - VOC KW - SVOC KW - Emission chamber test KW - Direct thermal extraction KW - Cultural heritage PY - 2005 SN - 7-89494-830-6 IS - 2 SP - 2269 EP - 2273 PB - Tsinghua University Press CY - Beijing AN - OPUS4-7602 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hahn, Oliver A1 - Wilke, Olaf A1 - Jann, Oliver T1 - Indoor air quality in show cases - an attempt to standardise emission measurements JF - Zeitschrift für Kunsttechnologie und Konservierung = Journal for art technology and conservation KW - Cultural heritage KW - Indoor air quality KW - Emission measurements PY - 2007 SN - 0931-7198 VL - 21 IS - 2 SP - 275 EP - 279 PB - Werner CY - Worms AN - OPUS4-17435 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Jann, Oliver A1 - Rockstroh, Jens A1 - Wilke, Olaf A1 - Noske, Reinhard A1 - Brödner, Doris A1 - Schneider, Uwe A1 - Horn, Wolfgang T1 - Development of a Test Method for and Investigation into Limiting the Emissions from Printers and Copiers within the Framework of Assigning the Environmental Label (Research Report 201 95 311/02 / UBA-FB 00,510E) T2 - UBA-Texte N2 - Kurzfassung An neun verschiedenen Hardcopygeräten wurden in unterschiedlichen Emissionsmesskammern (zwei verschiedene 1 m³ - Kammern und eine 20 m³ - Kammer) in Kombination mit geeigneten Probenahme- und Analysenverfahren Untersuchungen zum Emissionsverhalten dieser Geräte hinsichtlich Staub, Ozon und VOC (TVOC) durchgeführt. Luftprobenahme und Analytik erfolgten für VOC mittels Tenax TA und anschließender Thermodesorption (TDS) in Verbindung mit GC / MS. Ozon wurde kontinuierlich bestimmt. Der Ozonanalysator arbeitete auf der Grundlage der flammenlosen Reaktion von Ozon mit Ethylen nach dem Prinzip der Chemilumineszenz. Die Staubbestimmung erfolgte gravimetrisch mittels Glasfaserfilter und Ultramikrowaage. Zusätzlich wurde die Partikelemission während des Druckbetriebes mit einem Partikelzähler bestimmt. Aufgrund der technischen Rahmenbedingungen standen nur kurze Druckzeiten von maximal 36 Minuten zur Verfügung. Um die Gleichgewichtskonzentration in der Prüfkammer zu erreichen, wurde die Luftaustauschrate in den 1 m³ - Kammern auf n = 4,0 bis 4,7 pro Stunde erhöht. Zusätzlich zur Prüfung in den Emissionsmesskammern sind verschiedene Papiere mittels Direkt - TDS sowie unter- schiedliche Toner mittels Headspaceprobenahme in Kombination mit GC / MS hinsichtlich ihres Emissionsverhaltens untersucht worden. Für die untersuchten Geräte wurden Emissionsraten ermittelt. Sie betrugen für TVOC 0,41 bis 22,4 mg pro Stück und Stunde, für Ozon kleiner 0,02 bis 4,6 mg pro Stück und Stunde sowie für Staub 0,10 bis 7,63 mg pro Stück und Stunde. Verglichen mit Frischfaserpapier wurden bei den Untersuchungen mit Recyclingpapier deutlich höhere SVOC - Konzentrationen nachgewiesen. Im Ergebnis der Untersuchungen wurde ein Prüfverfahren entwickelt, das die Basis für Emissionsmessungen im Rahmen der Umweltzeichen RAL –UZ 62, RAL –UZ 85 sowie des neuen RAL –UZ 114 für Multifunktionsgeräte darstellt. Abstract The emission behaviour with regard to dust, ozone and VOC (TVOC) of nine different hardcopy devices in combination with suitable air sampling and analysis procedures was investigated in different emission test chambers (two different 1 m³ - chambers and one 20 m³ - chamber). Air sampling and analysis for VOC were done by means of Tenax TA and subsequent thermal desorption (TDS) in connection with GC / MS. Ozone was determined continuously. The ozone analyser worked on the basis of the flame rid reaction of ozone with ethylene according to the principle of chemiluminescence. The dust determination was done gravimetrically by means of glass fibre filter and an ultra micro - balance. Additional the particle emission during the printing process was measured with a particle counter. The general technical conditions of the tested hardcopy devices were the reason for short printing times with a maximum of 36 minutes. In order to achieve the equilibrium concentration in the test chambers the air exchange rate in the 1 m³ - test chambers had to be increased to a value of n = 4,0 to 4,7 per hour. Additional to the examination of the hardcopy devices in the emission test chambers different papers were investi- gated by means of direct - TDS and different toners were tested by means of head space sampling in combination with GC / MS. For the examined hardcopy devices emission rates were determined. The emission rates for TVOC ranged from 0,41 to 22,4 mg per piece and hour, for ozone from less than 0,02 to 4,6 mg per piece and hour and for dust from 0,10 to 7,63 mg per piece and hour. The comparison between recycling paper and paper produced from primary fibres showed in general higher SVOC emissions from recycling paper. As the result of the investigations a test method for the determination of emissions from hardcopy devices was developed. This test method is the basis for emission tests in the framework of the German Award of the Environmental Label for office devices RAL -UZ 62, RAL -UZ 85 and the new RAL -UZ 114 for multifunctional devices. KW - Emissions KW - VOC KW - Ozone KW - Dust KW - Hardcopy device KW - Printers KW - Copiers KW - Emission test chamber KW - Environmental label PY - 2003 UR - http://www.umweltbundesamt.de/publikationen/development-of-a-test-method-for-an-investigation SN - 1862-4804 SN - 0722-186X IS - 88 SP - 1 EP - 159 PB - Umweltbundesamt CY - Dessau-Roßlau AN - OPUS4-7277 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Jann, Oliver A1 - Wilke, Olaf T1 - Comparison of FLEC with other climate chambers, Gemeran experiences T2 - Proceedings of the 2nd International FLEC Symposium T2 - 2nd International FLEC Symposium CY - Copenhagen, Denmark DA - 2001-09-06 PY - 2001 SP - 18 EP - 27 AN - OPUS4-7204 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Plehn, W. A1 - Jann, Oliver A1 - Wilke, Olaf A1 - Brödner, Doris ED - Säteri, O. T1 - Eco-Label for low emission wood products and wood base products (RAL-UZ-38) - Part 1: Criteria and requirements for labeling T2 - Healthy buildings 2000 / Vol. 4: Materials, design and construction T2 - Healthy Buildings 2000 Conference CY - Espoo, Finland DA - 2000-08-06 PY - 2000 SN - 952-5236-06-4 VL - 4 SP - 519 EP - 524 PB - SIY Indoor Air Information CY - Helsinki AN - OPUS4-7206 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Jann, Oliver A1 - Wilke, Olaf A1 - Brödner, Doris ED - Woods, J. ED - Grimsrud, D. ED - Boschi, N. T1 - Procedure for the determination and limitation of VOC-emissions from furnitures and coated wood based products T2 - Healthy Buildings/IAQ '97 / Vol. 3: Residences T2 - Healthy Buildings/IAQ '97 ; ASHRAE Annual IAQ Conference ; 5th ISIAQ International Conference on Healthy Buildings CY - Bethesda, MD, USA DA - 1997-09-27 PY - 1997 SN - 0-929900-25-1 VL - 3 SP - 593 EP - 598 CY - Washington, DC AN - OPUS4-7237 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wiegner, Katharina A1 - Horn, Wolfgang A1 - Wilke, Olaf A1 - Kalus, Sabine A1 - Jann, Oliver T1 - Different possibilities for the statistical evaluation of round robin tests for volatile organic compounds in emission test chambers T2 - Healthy Buildings 2012 - 10th International conference (Proceedings) T2 - Healthy Buildings 2012 - 10th International conference CY - Brisbane, Australia DA - 2012-07-08 KW - Reference material KW - Round robin test KW - Emission test chamber KW - VOC-emission KW - Product emission testing PY - 2012 SN - 978-1-921897-40-5 SP - 1 EP - 2 (8B.6) AN - OPUS4-27526 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Jann, Oliver A1 - Wilke, Olaf T1 - Sampling and analysis of wood preservatives in test chambers T2 - Organic Indoor Air Pollutants PY - 1999 SN - 3-527-29622-0 SP - 31 EP - 43 PB - Wiley-VCH CY - Weinheim AN - OPUS4-7200 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Wilke, Olaf A1 - Kirchner, D. A1 - Jann, Oliver A1 - Kemmlein, S. A1 - Kalus, Sabine A1 - Süßmilch, C. T1 - European interlaboratory study for sampling VOC emissions - Step 1 - Liquid samples added on Tenax tubes T2 - Indoor Air 2008, 11th International Conference on Indoor Air Quality and Climate, August 17-22, 2008, Copenhagen, Denmark (Proceedings) T2 - Indoor Air 2008, 11th International Conference on Indoor Air Quality and Climate CY - Copenhagen, Denmark DA - 2008-08-17 KW - ISO 16000-6 KW - VOC analysis KW - Interlaboratory study KW - Emission tests KW - Building material PY - 2008 IS - Paper 226 SP - 1 AN - OPUS4-18048 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Kalus, Sabine A1 - Brödner, Doris A1 - Juritsch, Elevtheria A1 - Süßmilch, C. A1 - Kirchner, D. T1 - European interlaboratory study for sampling VOC emissions - Step 2 - Sampling with Tenax tubes at an emission test chamber T2 - Indoor Air 2008, 11th International Conference on Indoor Air Quality and Climate, August 17-22, 2008, Copenhagen, Denmark (Proceedings) T2 - Indoor Air 2008, August 17-22, 2008 CY - Copenhagen, Denmark DA - 2008-08-17 KW - VOC KW - Tenax thermal desorption KW - Emission test chamber KW - Proficiency testing KW - Interlaboratory study PY - 2008 IS - Paper ID: 238 SP - 1 AN - OPUS4-17864 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wilke, Olaf A1 - Jann, Oliver A1 - Brödner, Doris T1 - Fast and reliable determination of emissions from carpet adhesives JF - GERSTEL Solutions worldwide PY - 2005 UR - http://www.gerstel.com/magazine_solution_05.htm SN - 1619-0076 IS - 5 SP - 4 EP - 5 CY - Mülheim an der Ruhr AN - OPUS4-7323 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Richter, Matthias A1 - Wilke, Olaf A1 - Jann, Oliver T1 - Use of emission test chambers for the determination of chemical emissions from construction materials T2 - 1st International conference on the chemistry of construction materials (Proceedings) T2 - 1st International conference on the chemistry of construction materials CY - Berlin, Germany DA - 2013-10-07 KW - VOC KW - Emission from materials KW - Construction materials KW - Emission test chamber PY - 2013 SN - 978-3-936028-75-1 N1 - Serientitel: GDCh-Monographien – Series title: GDCh-Monographien VL - 46 SP - 259 EP - 262 AN - OPUS4-29480 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pech, Anja A1 - Wilke, Olaf A1 - Horn, Wolfgang A1 - Jann, Oliver T1 - Analysis of very volatile organic compounds (VVOC) with thermal desorption GC-MS T2 - Proceedings of Indoor Air 2016, The 14th international conference of Indoor Air Quality and Climate N2 - Most VVOC were rarely considered in the evaluation of construction products. (Salthammer, 2014) In Germany this will change because the latest version of the German AgBB scheme for health evaluation (2015) now include VVOC, e.g. ethyl acetate and ethanol. In this study selected compounds were tested with the procedure described in ISO 16017 and a method for measuring VVOC with thermal desorption was developed. Three different adsorbents Tenax TA, Carbograph 5TD and Carbopack X were tested to analyse VVOC according to ISO 16017. For the tested VVOC, Carbograph 5TD showed the best results under the chosen analytical conditions. T2 - Indoor Air 2016, The 14th international conference of Indoor Air Quality and Climate CY - Gent, Belgium DA - 03.07.2016 KW - Thermal desorption KW - VVOC KW - Carbograph 5TD KW - Carbopack X PY - 2016 SP - Paper 889, 1 EP - 2 AN - OPUS4-37035 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Wilke, Olaf A1 - Wiegner, Katharina A1 - Jann, Oliver A1 - Kalus, Sabine A1 - Till, Carola T1 - Interlaboratory study with Tenax thermal desorption - Phase 1 - liquid samples added onto tenax tubes T2 - Healthy buildings 2009 - 9th International conference & exhibition (Proceedings) T2 - Healthy buildings 2009 - 9th International conference & exhibition CY - Syracuse, NY, USA DA - 2009-09-13 KW - ISO 16000-6 KW - Interlaboratory study KW - VOC KW - External quality management system PY - 2009 IS - Paper 355 SP - 1 EP - 2 CY - Syracuse, NY, USA AN - OPUS4-19923 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wiegner, Katharina A1 - Wilke, Olaf A1 - Jann, Oliver A1 - Brödner, Doris A1 - Scheffer, Harald A1 - Kalus, Sabine A1 - Till, Carola T1 - Study on VOC-Emissions from Oriented Strand Boards (OSB) T2 - Healthy buildings 2009 - 9th International conference & exhibition (Proceedings) T2 - Healthy buildings 2009 - 9th International conference & exhibition CY - Syracuse, NY, USA DA - 2009-09-13 KW - Volatile organic compound (VOC) KW - Aldehyde KW - Antioxidant KW - Wood KW - Oriented strand boards (OSB) PY - 2009 IS - Paper 247 SP - 1 EP - 4 CY - Syracuse, NY, USA AN - OPUS4-19928 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Kalus, Sabine A1 - Brödner, Doris A1 - Juritsch, Elevtheria A1 - Till, Carola A1 - Kirchner, D. T1 - European interlaboratory study for sampling VOC emissions - Step 3 - Emission test chamber measurements T2 - Healthy buildings 2009 - 9th International conference & exhibition (Proceedings) T2 - Healthy buildings 2009 - 9th International conference & exhibition CY - Syracuse, NY, USA DA - 2009-09-13 KW - VOC emission KW - Emission test chamber KW - Round robin test KW - Construction products KW - Tenax thermal desorption PY - 2009 IS - Paper 343 SP - 1 EP - 4 CY - Syracuse, NY, USA AN - OPUS4-20093 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Richter, Janine A1 - Wilke, Olaf A1 - Jann, Oliver T1 - Emissions of formaldehyde and VOC from wood-based building products T2 - Proceedings of Healthy Buildings 2017 Europe N2 - Wood-based materials are well-known sources for formaldehyde emission in the indoor environment. Different testing standards lead to different emission values for the materials. Such standards are compared in this study. Besides scenarios with varying loading factors, air exchange rates and climatic conditions were investigated to evaluate the formaldehyde emission potential of different building products. Under realistic indoor conditions used for the emission chamber tests, exceeding of formaldehyde indoor guide values were obtained. Results showed the need for improvement of wood-based materials with lower formaldehyde emissions and the adaption of testing parameters closer to realistic conditions. T2 - Healthy Buildings 2017 Europe CY - Lublin, Poland DA - 02.07.2017 KW - Formaldehyde KW - Emission chamber testing KW - Particle board KW - OSB PY - 2017 SN - 978-83-7947-232-1 SP - Paper 0175, 1-6 AN - OPUS4-41575 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Jann, Oliver T1 - Emissions of very volitale organic compounds (VVOC) from particle boards T2 - Proceedings of the 14th international conference of Indoor Air Quality and Climate, Indoor Air 2016 N2 - The latest version of the German AgBB evaluation scheme (2015) for construction products includes some VVOC, e.g. formaldehyde, acetaldehyde and acetone. For these VVOC so-called LCI values (lowest concentration of interest) were derived which are used for the calculation of the so-called R-value (risk index, see reference 1 for the calculation). Test chamber measurements of particle boards show that the emissions of VVOC might have significant impact on the R-value and therefore for the health evaluation. T2 - The 14th international conference of Indoor Air Quality and Climate, Indoor Air 2016 CY - Gent, Belgium DA - 03.07.2016 KW - Formaldehyde KW - AgBB evaluation scheme KW - Particle board KW - OSB KW - VVOC KW - Emission test chamber PY - 2016 SP - Paper 965, 1 AN - OPUS4-37030 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Richter, Janine A1 - Jann, Oliver A1 - Wilke, Olaf T1 - Emissions of formaldehyde from acoustic tiles T2 - Proceedings of Healthy Buildings 2017 Europe N2 - Acoustics is an important aspect for large rooms especially in schools, kindergartens and offices. Foam tiles made from melamine resins are often used for acoustic insulation because they show good fire resistance and good thermal insulation properties. But they can emit formaldehyde. In Germany there are cases with a resulting indoor air concentration of higher than 100 µg/m³. In this study samples from two schools and one office were investigated. Additionally, new tiles were purchased and tested to evaluate the general potential as formaldehyde source. T2 - Healthy Buildings 2017 Europe CY - Lublin, Poland DA - 02.07.2014 KW - Building product KW - Emission test chamber KW - Formaldehyde KW - Foam tiles PY - 2017 SN - 978-83-7947-232-1 SP - Paper 0176, 1-2 AN - OPUS4-41574 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Jann, Oliver T1 - Comparison of Formaldehyde Concentrations in Emission Test Chambers Using EN 717-1 and EN 16516 T2 - Proceedings of Indoor Air Conference 2018 N2 - For more than 25 years EN 717-1 (Wood-based panels - Determination of formaldehyde re-lease - Part 1: Formaldehyde emission by the chamber method) is the standard for formalde-hyde emission testing of wooden boards. In 2017 EN 16516 (Construction products - Assess-ment of release of dangerous substances - Determination of emissions into indoor air) was published as a new harmonised standard for the emission testing of construction products. Because test chamber conditions are different, both standards give different concentrations for formaldehyde. To determine a conversion factor four test series were set up with different wooden boards. For a loading of 1 m²/m³ the conversion factor is 1.6. This means that the formaldehyde concentration measured under the conditions of EN 16516 is a factor of 1.6 higher compared to EN 717-1. T2 - Conference on Indoor Air CY - Philadelphia, PA, USA DA - 22.07.2018 KW - Loading factor KW - European standard KW - Construction products KW - Air exchange rate PY - 2018 SP - paper 627 AN - OPUS4-45630 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Wilke, Olaf T1 - Suitability of small environmental chambers to test the emission of biocides from treated materials into the air JF - Atmospheric environment N2 - Biocides are used to protect materials that might be damaged by fungal, microbial or insect activity. The aim of this study is to develop a method for the measurement of these organic compounds, which generally have low or moderate vapor pressures. The biocides considered in this study are permethrin, dichlofluanid, tolylfluanid, iodpropinylbutylcarbamat, octylisothiazolinone, tebuconazole and propiconazole. The emission from two commercial products (plastic foil, wool carpet) containing biocides and of seven types of biocidal formulations applied to wood or clay tiles were investigated in 20-l glass emission test chambers. Each chamber test was performed over a period of 100–200 days, and one investigation was conducted over several years. Compared to volatile organic compounds, low-volatility compounds show totally different emission curves in chamber tests; maximal emission values may be reached in days or weeks. A period of 3 months is sometimes necessary for the determination of area-specific emission rates (SERa's). The SERa's (?g m-2 h-1) from biocide-containing products were determined for permethrin (0.006), propiconazole (0.3), dichlofluanid (2.0), tolylfluanid (1.0), octylisothiazolinone (2.5) and iodpropinylbutylcarbamat (2). In most cases, the SERa stayed at its maximum value or declined slowly over the test period. Additionally, a chamber test begun in 1994 with a piece of wood treated with a typical mixture of biocides dissolved in a technical solvent was continued. SERa's (?g m-2 h-1) for dichlofluanid (0.20), tebuconazole (0.49) and permethrin (0.08) remained detectable after the period of nearly 9 years during which the sample remained continuously in the chamber. This test proved the very slow decrease of emission of low-volatility compounds like permethrin and tebuconazole. KW - Indoor air KW - Biocides KW - Emission test chamber KW - SVOC PY - 2003 DO - https://doi.org/10.1016/j.atmosenv.2003.09.024 SN - 0004-6981 SN - 1352-2310 VL - 37 IS - 39-40 SP - 5477 EP - 5483 PB - Elsevier CY - Amsterdam AN - OPUS4-2676 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Burbiel, M. A1 - Wilke, Olaf A1 - Kalus, Sabine ED - Levin, H. T1 - Biocide emissions from materials into indoor air T2 - Indoor air 2002 N2 - The European biocides directive (98/8/EG) demand the control of emissions into the envi-ronment like soil, water and air. In this study a method for measuring the input of biocides into the indoor air from materials should be developed. The emission of two products containing biocides (plastic foil, wool carpet) and six different types of biocide containing formulations applied on wood or ceramic tiles were investigated in 20 or 23 l glass emission chambers. Each chamber test was performed over a period of 100 up to 200 days. SVOC show totally different emission curves in chamber tests compared to volatile organic com-pounds (VOC). They reach their maximum value after some days or weeks. Thus a period of 3 months is sometimes necessary for exact measurements. Area specific emission rates (SERa in µg/m²h) for permethrin (0.006), propiconazole (0.2), dichlofluanid (1.5), tolylfluanid (1.2), octylisothiazolinone (2.5) and for iodpropinylbutyl-carbamat (1.7) were determined. T2 - 9th International Conference on Indoor Air Quality and Climate CY - Monterey, CA, USA DA - 2002-06-30 KW - SVOC KW - Biocide KW - Chamber test KW - Polyurethane foam KW - Testing method PY - 2002 UR - http://www.irbnet.de/daten/iconda/CIB6909.pdf SN - 0-9721832-0-5 VL - 2 SP - 926 EP - 930 PB - International Academy of Indoor Air Sciences CY - Santa Cruz, Calif. AN - OPUS4-2000 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Wilke, Olaf A1 - Jann, Oliver A1 - Brödner, Doris ED - Levin, H. T1 - VOC- and SVOC-Emissions from Adhesives, Floor Coverings and Complete Floor Structures T2 - Indoor air 2002 N2 - VOC/SVOC-Emissions from materials for flooring installation (primer, screed, adhesive, floor covering) were measured by means of emission test chambers and cells over a time period of at least 28 days at 23 C, 50 % relative humidity and an area specific air flow rate of q = 1.25 m³/m²h. Single components were tested in comparison to three complete structures (same concrete, primer, screed, adhesive) with different types of floor covering (PVC, carpet, linoleum). Sorption into concrete/screed and different sealing by the flooring materials affected the emissions from the complete structures. The complete structures with linoleum and PVC showed the same emissions and emission rates as the flooring materials alone. Emissions from the carpet-covered structure resulted mainly from the lower layers. For two adhesives the formation of secondary emissions (aldehydes and organic acids) was observed starting after the standard testing time of 28 days. T2 - 9th International Conference on Indoor Air Quality and Climate CY - Monterey, CA, USA DA - 2002-06-30 KW - Test chambers KW - VOCs and SVOCs KW - Secondary emissions KW - Construction and renovation PY - 2002 UR - https://www.irbnet.de/daten/iconda/CIB6472.pdf SN - 0-9721832-0-5 VL - 1 SP - 962 EP - 967 PB - International Academy of Indoor Air Sciences CY - Santa Cruz, Calif. AN - OPUS4-2002 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Rockstroh, Jens A1 - Jann, Oliver A1 - Wilke, Olaf A1 - Noske, Reinhard A1 - Brödner, Doris A1 - Schneider, Uwe A1 - Horn, Wolfgang ED - Wai, T. K. ED - Sekhar, C. ED - Cheong, D. T1 - Investigations on VOC, ozone and dust emissions from hardcopy devices (laser printers, copiers and multifunctional devices) in test chambers - development of a test method T2 - Healthy Buildings 2003 T2 - 7th Healthy Buildings Conference ; HB 2003 ; ISIAQ international conference CY - Singapore, Republic of Singapore DA - 2003-12-07 KW - Emissions KW - Printers KW - Copiers KW - VOC KW - Dust KW - Ozone KW - Blue Angel PY - 2003 SN - 981-049974-4 VL - 1 SP - 397 EP - 403 CY - Singapore AN - OPUS4-3315 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Wilke, Olaf A1 - Jann, Oliver A1 - Brödner, Doris ED - Wai, T. K. ED - Sekhar, C. ED - Cheong, D. T1 - VOC and SVOC Contribution of Papers for Hardcopy Devices to Indoor Air Pollution T2 - Healthy Buildings 2003 T2 - 7th Healthy Buildings Conference ; HB 2003 ; ISIAQ international conference CY - Singapore, Republic of Singapore DA - 2003-12-07 PY - 2003 SN - 981-049974-4 VL - 1 SP - 289 EP - 295 CY - Singapore AN - OPUS4-3377 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Jann, Oliver A1 - Wilke, Olaf A1 - Brödner, Doris A1 - Plehn, W. ED - Säteri, O. T1 - Eco-Label for low emission wood products and wood base products (RAL-UZ-38) - Part 2: Test procedure and results T2 - Healthy buildings 2000 / Vol. 4: Materials, design and construction T2 - Healthy Buildings 2000 Conference CY - Espoo, Finland DA - 2000-08-06 PY - 2000 SN - 952-5236-06-4 VL - 4 SP - 525 EP - 530 PB - SIY Indoor Air Information CY - Helsinki AN - OPUS4-7205 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Wilke, Olaf A1 - Jann, Oliver A1 - Brödner, Doris ED - Säteri, O. T1 - Investigations on the emission behavior of low-emitting adhesives for flooring materials T2 - Healthy buildings 2000 / Vol. 4: Materials, design and construction T2 - Healthy Buildings 2000 Conference CY - Espoo, Finland DA - 2000-08-06 PY - 2000 SN - 952-5236-06-4 VL - 4 SP - 391 EP - 396 PB - SIY Indoor Air Information CY - Helsinki AN - OPUS4-7207 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Wilke, Olaf A1 - Jann, Oliver A1 - Brödner, Doris A1 - Rother, Ingrid T1 - Comparison of different types of emission test chambers and cells regarding VOC- and SVOC-emission T2 - Indoor Air 2005 T2 - Indoor Air 2005 CY - Beijing, PR China DA - 2005-09-04 KW - Emission KW - Chamber KW - Cell KW - Building product KW - VOC KW - SVOC PY - 2005 SN - 7-89494-830-6 IS - 2 SP - 6 pages PB - Tsinghua University Press CY - Beijing AN - OPUS4-11075 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Jann, Oliver A1 - Rockstroh, Jens A1 - Wilke, Olaf T1 - Influence of emissions from hardcopy devices to indoor air quality T2 - Indoor Air 2005 T2 - Indoor Air 2005 CY - Beijing, PR China DA - 2005-09-04 KW - VOC KW - TVOC KW - Dust KW - Ozone KW - Hardcopy devices PY - 2005 SN - 7-89494-830-6 IS - 2 SP - 6 pages PB - Tsinghua University Press CY - Beijing AN - OPUS4-11074 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Seeger, Stefan A1 - Wilke, Olaf A1 - Bücker, Michael A1 - Jann, Oliver T1 - Time- and Size-Resolved Characterization of Particle Emissions from Office Machines with Printing Function T2 - Proceedings of Healthy Buildings 2006 T2 - Healthy Buildings 2006 CY - Lisboa, Portugal DA - 2006-06-04 KW - Hard copy devices KW - Laserprinters KW - Toner KW - Particle emissions KW - Particles KW - Aerosols PY - 2006 SN - 978-989-95067-1-8 VL - 2 SP - 447 EP - 450 CY - Lissabon AN - OPUS4-14522 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Wiegner, Katharina A1 - Wilke, Olaf A1 - Jann, Oliver T1 - Method validation study for VOC emission measurements T2 - Indoor Air 2011, 12th International conference on indoor air quality and climate (Proceedings) N2 - Quality and trueness of results received from measurements are very important for all involved parties, producers and consumers as well; for instance, if the results were used for acceptance of a product within a labeling procedure. Based on an inter-laboratory study with many German, European and US-American laboratories an extemal quality assurance System for the analysis of VOC emitting from products or the measurement in indoor air should be implemented (financed by the German Federal Environmental Agency). A focus was set on the emission test chamber experiments and the connected analytical procedure. VOC have a dominating influence when applying the German AgBB scheme for health evaluation of building products. Therefore it is necessary to ensure that the results between the testing laboratories are comparable. The successful participation to such round robin tests is offen essential for the acceptance of results given by an analytical laboratory. T2 - Indoor Air 2011, 12th International conference on indoor air quality and climate CY - Austin, TX, USA DA - 05.06.2011 KW - Round robin test KW - VOC KW - Construction product KW - Emission PY - 2011 IS - Paper 768 SP - 1 EP - 2 AN - OPUS4-23880 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Horn, Wolfgang A1 - Wiegner, Katharina A1 - Jann, Oliver A1 - Kalus, Sabine A1 - Till, Carola T1 - Interlaboratory study with Tenax thermal desorption - Phase 2 - Tenax tubes spiked by BAM T2 - Healthy buildings 2009 - 9th International conference & exhibition (Proceedings) T2 - Healthy buildings 2009 - 9th International conference & exhibition CY - Syracuse, NY, USA DA - 2009-09-13 KW - ISO 16000-6 KW - Interlaboratory study KW - VOC KW - External quality management system PY - 2009 IS - Paper 345 SP - 1 EP - 2 CY - Syracuse, NY, USA AN - OPUS4-20094 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Seeger, Stefan A1 - Bresch, Harald A1 - Brödner, Doris A1 - Juritsch, Elevtheria A1 - Jann, Oliver T1 - Sampling and characterisation of ultra fine particles released from laser printers T2 - Indoor Air 2008, 11th International Conference on Indoor Air Quality and Climate, August 17-22, 2008, Copenhagen, Denmark (Proceedings) T2 - Indoor Air 2008, August 17-22, 2008 CY - Copenhagen, Denmark DA - 2008-08-17 KW - Aerosol KW - Ultra fine particle KW - Laser printer KW - Cyclosiloxanes PY - 2008 IS - Paper ID: 239 SP - 1 AN - OPUS4-17865 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -