TY - CONF A1 - Sergeeva-Chollet, N. A1 - Decitre, J.-M. A1 - Fermon, C. A1 - Pelkner, Matthias A1 - Reimund, Verena A1 - Kreutzbruck, Marc ED - Chimenti, D.E. ED - Bond, L.J. ED - Thompson, D.O. T1 - Development of eddy current probes based on magnetoresistive sensors arrays T2 - 40th Annual review of progress in quantitative nondestructive evaluation (Proceedings) N2 - Eddy Current Technique is a powerful method for detection of surface notches and of buried flaws during inspection of metallic parts. Recent EC array probes have demonstrated a fast and efficient control of large surfaces. Nevertheless, when the size of flaws decreases or the defect is rather deep, traditional winding coil probes turn out to be useless. Magnetoresistive sensors present the advantages of flat frequency response and micron size. These sensors are hence very attractive for the detection of buried defects that require low frequencies because of skin depth effect. An optimization of the probe with magnetoresistive sensors as receivers has been made by simulations using CIVA software and finite elements methods with OPERA. EC probes for buried flaw detection have been designed. Experimental results have been compared with simulations. T2 - 40th Annual review of progress in quantitative nondestructive evaluation CY - Baltimore, Maryland, USA DA - 2013-07-21 KW - Eddy current KW - Magnetic sensor PY - 2014 SN - 978-0-7354-1212-5 SN - 978-0-7354-1211-8 DO - https://doi.org/10.1063/1.4864981 SN - 0094-243X N1 - Serientitel: AIP conference proceedings – Series title: AIP conference proceedings VL - 1581 33B SP - 1374 EP - 1379 PB - AIP Publishing AN - OPUS4-31279 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pelkner, Matthias A1 - Erthner, Thomas A1 - Reimund, Verena A1 - Kreutzbruck, Marc A1 - Sergeeva-Chollet, N. T1 - MR-based eddy current probe design for hidden defects T2 - ECNDT 2014 - 11th European conference on non-destructive testing (Proceedings) N2 - We present a simulation study which pursues the objective to find probe geometries for a MR-based eddy current (EC) probe (MR magneto resistance, e.g., GMR giant magneto resistance, TMR tunnel magneto resistance). MR sensor technology exhibits two significant advantages compared with conventional coil systems. First, MR sensors are relatively frequency-independent within common EC-frequency ranges which enable us to operate them in hidden defects testing problems. Secondly, MR technology is well suited for miniaturization helping us to design small elements in the order of below 100 µm. In this paper simulation and experimental results obtained with the probes for low frequency application, i.e. for hidden defects detection are discussed. Our simulations are based on two different approaches for a better validation, a commercial finite element method software (Opera, Vectorfields) and the semi-analytical software CIVA. We investigated both coil arrangement in order to excite sufficient high eddy currents inside the test samples and position of MR-elements at the array chip. In doing so the MR sensors were positioned that they are not exposed to excitation fields. In addition, different coil geometries, in particular coil length, e.g. Ι = 20 mm, were analyzed in order to generate a consistent eddy current distribution beneath an array of up to 32 MR-elements. To prove obtained probe principles we built GMR-EC-probes. The first test measurements are in good agreement with the simulations performed by BAM and CEA. On basis of our findings the IMAGIC consortium developed new MR-EC-probes using integrated ASIC technology. T2 - ECNDT 2014 - 11th European conference on non-destructive testing CY - Prague, Czech Republic DA - 2014-10-06 KW - Magneto resistance (MR) KW - Eddy current (EC) KW - Simulation KW - GMR KW - Magnetic flux leakage KW - Hidden defects PY - 2014 UR - http://www.ndt.net/events/ECNDT2014/app/content/Paper/409_Pelkner.pdf SN - 978-80-214-5018-9 SP - 1 EP - 8(?) AN - OPUS4-32231 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pelkner, Matthias A1 - Pohl, Rainer A1 - Erthner, Thomas A1 - Stegemann, Robert A1 - Kreutzbruck, Marc A1 - Sergeeva-Chollet, N. T1 - Eddy current testing with high-spatial resolution probes using MR arrays as receiver T2 - 7th International symposium on NDT in aerospace (Proceedings) N2 - Magneto-resistive (MR) sensor arrays are suited for high resolution eddy current testing (ET) of aerospace components due to two significant advantages compared to conventional coil systems. First, to obtain high spatial resolution they can be manufactured down to the µm-regime without losing their outstanding field sensitivity. Secondly, MR technology has a relatively frequency-independent sensitivity in the range of common ET-frequencies thus providing a benefit for low frequency applications. This paper presents measurements using MR array probes consisting of 32 TMR-elements (tunnel magneto resistance), an ASIC, and subsequent readout components. A source for generating the eddy currents inside the material under test is also implemented onboard of the PCB. These probes were developed in the IMAGIC-project* for detection and imaging of surface breaking defects. The performance of the new sensor system has been investigated for several mock-ups, Aluminum and Titanium plate specimens having small adjacent boreholes with diameter of 0.44 mm and micro notches in the µm-range, respectively. To compare our results we used conventional eddy current probes. The MR sensor elements have a length of around 60 µm leading to a nearly 'point like' measurement. Neighbouring boreholes (depth 0.25 mm) with a separation of 0.6 mm between their centres could be resolved with a good SNR, and more important, the boreholes could be confidently distinguished using the TMR-probes. In case of conventional probes a reliable separation was not possible. In this paper we present the MR-ET-probes of the IMAGIC consortium and a comparison with conventional techniques. *The IMAGIC-project ('Integrated Magnetic imagery based on spIntronics Components', 2011 – 2014, project reference: 288381) was funded by the European Commission, Seventh Framework Programme. Further partners involved in the consortium beside BAM and CEA were INESC-ID and INESC-MN (Portugal), Sensitec GmbH (Germany), Tecnatom S.A. (Spain), and Airbus Group (France). T2 - 7th International symposium on NDT in aerospace CY - Bremen, Germany DA - 16.11.2015 KW - TMR KW - GMR KW - Sensor array KW - Eddy current testing (ET) KW - Aerospace PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-344254 SN - 978-3-940283-76-4 N1 - Serientitel: DGZfP-Proceedings – Series title: DGZfP-Proceedings IS - DGZfP-BB 156 SP - We.5.A.4, 1 EP - 8 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung e.v. (DGZfP) AN - OPUS4-34425 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -