TY - JOUR A1 - Weber, Mike A1 - Wille, Frank A1 - Ballheimer, Viktor A1 - Musolff, André T1 - From experiment to appropriate finite element model-safety assessment for ductile cast iron casks demonstrated by means of IAEA puncture drop test JF - Packaging, transport, storage & security of radioactive materials (RAMTRANS) N2 - In the approval procedure of transport packages for radioactive materials, the competent authority mechanical and thermal safety assessment is carried out in Germany by BAM Federal Institute for Materials Research and Testing. The combination of experimental investigations and numerical calculations in conjunction with materials and components testing is the basis of the safety assessment concept of the BAM. Among other mechanical test scenarios, a 1 metre drop test onto a steel bar has to be considered for the application of the hypothetical accident conditions to Type B packages according to IAEA regulations. Within the approval procedure for the new German package design of the HLW cask CASTOR® HAW 28M, designed by GNS Gesellschaft für Nuklear-Service Germany, a puncture drop test was performed with a half-scale model of the cask at -40°C. For independent assessment and to control the safety analysis presented by the applicant, BAM developed a complex finite element (FE) model for a dynamical ABAQUS/ExplicitTM analysis. This paper describes in detail the use of the FE method for modelling the puncture drop test within an actual assessment strategy. At first, investigations of the behaviour of the steel bar were carried out. Different friction coefficients and the material law of the bar were analysed by using a 'rigid-body' approximation for the cask body. In the next step, a more detailed FE model with a more realistic material definition for the cask body was developed. The validation of calculated strains was carried out by comparison with the results of the strain gauges located at the relevant points of the cask model. The influence of the FE meshing is described. Finally, the validated FE half-scale model was expanded to full-scale dimension. Scaling effects were analysed. The model was used for safety assessment of the package to be approved. KW - IAEA puncture drop test KW - Cylindrical cask KW - Explicit dynamics KW - Scaled model KW - Numerical analysis KW - Validation KW - Safety assessment PY - 2011 DO - https://doi.org/10.1179/1746510911Y.0000000010 SN - 1746-5095 SN - 1746-5109 SN - 0957-476X VL - 22 IS - 3 SP - 148 EP - 153 PB - Ramtrans Publ. CY - Ashford AN - OPUS4-25356 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -