TY - JOUR A1 - Wiegner, Katharina A1 - Hahn, Oliver A1 - Horn, Wolfgang A1 - Farke, M. A1 - Kalus, Sabine A1 - Nohr, Michael A1 - Jann, Oliver T1 - Determination of formic and acetic acid emissions in indoor air or from building products N2 - Several construction and building materials, including wood, glue and coatings, are possible sources of very volatile organic compounds (VVOCs) and volatile organic compounds (VOCs) like formic and acetic acid. Due to very high air tightness and very low air exchange rates in new buildings concentrations of these harmful substances can increase considerably. To minimize the risk, emissions from building products should be identified and quantified. With the common standard method, this means Tenax® sampling followed by thermal desorption and GC-MS analysis, these acids could not be detected sufficiently. The aim oft this study is the comparison of two different methods for the determination of acetic and formic acid. The sampling of method one, which is usually used for identification and quantification of VOCs, is done in accordance with ISO 16000-6 and ISO 16017-1 on Carbotrap® 202 multi-bed thermal desorption tube by subsequent identification and quantification with GC-MS. Method two is based on sampling on 2,4-dinitrophenylhydrazine (DNPH) cartridges, derivatisation, elution, identification and quantification of the derivatives with LC-MS/MS (liquid chromatography – mass spectrometry/mass spectrometry). N2 - Viele Konstruktions- und Baumaterialien, wie Holz, Kleber und Anstriche, sind mögliche Quellen für leicht flüchtige organische Verbindungen (VVOC) und flüchtige organische Verbindungen (VOC), wie Ameisen- und Essigsäure. Bedingt durch die hohe Dichtigkeit und den damit verbundenen niedrigen Luftwechsel in neuen Gebäuden können die Konzentrationen dieser gesundheitsgefährdenden Substanzen beträchtlich ansteigen. Um das Risiko zu minimieren, sollen Emissionen aus Bauprodukten identifiziert und quantifiziert werden. Mit der üblichen Standardmethode, die auf einer Luftprobenahme auf Tenax® und anschließender Analyse mittels GC-MS basiert, können diese Säuren nicht ausreichend detektiert werden. Ziel dieser Arbeit ist der Vergleich von zwei unterschiedlichen Methoden zur Bestimmung von Essig- und Ameisensäure. Die Luftprobenahme der ersten Methode, die üblicherweise zur Identifizierung und Quantifizierung von VOC genutzt wird, wurde gemäß ISO 16000-6 and ISO 16017-1 auf Carbotrap® 202, ein mit mehreren Adsorbentien gepacktes Thermodesorptionsrohr, mit anschließender Identifikation und Quantifizierung mittels GC-MS durchgeführt. Die zweite Methode basiert auf einer Luftprobenahme mittels 2,4-Dinitrophenylhydrazin-(DNPH)-Kartuschen, Derivatisierung, Elution, Identifikation und Quantifizierung der Derivate mit LC-MS/MS (Flüssigkeitschromatographie – Massenspektometrie/Massenspektometrie). KW - Formic acid KW - Acetic acid KW - VVOCs KW - Air sampling KW - DNPH PY - 2012 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-255911 UR - http://www.gefahrstoffe.de/gest/article.php?data[article_id]=65887 SN - 0949-8036 SN - 0039-0771 SN - 1436-4891 VL - 72 IS - 3 SP - 84 EP - 88 PB - Springer-VDI-Verlag CY - Düsseldorf AN - OPUS4-25591 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wiegner, Katharina A1 - Horn, Wolfgang A1 - Stephan, Ina A1 - Nohr, Michael A1 - Lau, Angelika A1 - Farke, M. A1 - Hahn, Oliver T1 - Überprüfung möglicher mikrobieller Belastungen in Vitrinenluft durch Kleinklimageräte N2 - Unterschiedliche Befeuchtungssysteme für Vitrinen, die die Ausstellungsobjekte bei definierter Luftfeuchtigkeit vor externen Einflüssen wie Staub bewahren sollen, wurden im Hinblick auf die Möglichkeit der potenziellen mikrobiologischen Kontamination untersucht. Ergänzend hierzu wurden Parameter wie pH-Wert und Leitfähigkeit des Wassers im Befeuchter untersucht und die mikrobiellen flüchtigen organischen Verbindungen (MVOC, microbial volatile organic compounds) in der Modellvitrine bestimmt. Die Leitfähigkeitsmessung kann als Indikator für den Verunreinigungsgrad des Wassers dienen, weil sie mit der mikrobiologischen Belastung korreliert. Weiterhin war eine mikrobiologische Belastung der Luft in der Modellvitrine auch bei relativ hoher Verunreinigung des Befeuchtungswassers nicht nachzuweisen. KW - MVOC (microbial volatile organic compounds) KW - Schimmelpilze KW - Kleinklimagerät KW - Vitrinen KW - Essigsäure PY - 2011 SN - 0949-8036 SN - 0039-0771 SN - 1436-4891 VL - 71 IS - 9 SP - 378 EP - 381 PB - Springer-VDI-Verl. CY - Düsseldorf AN - OPUS4-24340 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wiegner, Katharina A1 - Hahn, Oliver A1 - Farke, M. A1 - Stephan, Ina A1 - Nohr, Michael A1 - Horn, Wolfgang T1 - Development of methods for testing of microbiological contamination of small climate control units for air in display cases T2 - Healthy Buildings 2012 - 10th International conference CY - Brisbane, Australia DA - 2012-07-08 KW - Microbiological contamination KW - Acetic and formic acid KW - Conductivity KW - Climate control device KW - Display case KW - Normung KW - Geruch KW - Messmethoden KW - Emissionsmessung KW - Bauprodukte PY - 2012 SN - 978-1-921897-40-5 SP - 1 EP - 2 (5H.2) AN - OPUS4-27562 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -