TY - CONF A1 - Maiwald, Michael T1 - On-line NMR -Spektroskopie in der Prozessanalytik T2 - Moderne Methoden der NMR-Spektroskopie, Universität Tübingen CY - Tübingen, Germany DA - 2011-10-10 PY - 2011 AN - OPUS4-25153 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Maiwald, Michael T1 - On-line NMR-Spektroskopie in der prozessanalytik T2 - Moderne Methoden der NMR-Spektroskopie, Universität Tübingen CY - Tübingen, Germany DA - 2011-10-10 PY - 2011 AN - OPUS4-24980 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Maiwald, Michael A1 - Guthausen, G. A1 - Dalitz, F. T1 - Investigations of Flow in Quantitative NMR T2 - EUROMAR2011 CY - Frankfurt am Main, Germany DA - 2011-08-21 PY - 2011 AN - OPUS4-24303 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Maiwald, Michael T1 - Prozessanalytik: Konzepte und Strategien - Prozessanalytik in Flüssigkeiten T2 - GDCh-PAT-Weiterbildungsmodul "Konzepte und Strategien" 2012 CY - Frankfurt am Main, Germany DA - 2012-10-23 PY - 2012 AN - OPUS4-27028 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Maiwald, Michael T1 - Prozessanalytik 2012 Stand&Tendenzen T2 - Teilchengrößenanalytik in Prozessen: Messtechniken für Emulsionen und Suspensionen CY - Potsdam, Germany DA - 2012-10-10 PY - 2012 AN - OPUS4-27029 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Maiwald, Michael A1 - Meyer, Klas A1 - Kipphardt, Heinrich T1 - Quantitative NMR spectroscopy for Gas Analysis T2 - Gas 2013 Konferenz CY - Rotterdam, Netherlands DA - 2013-06-05 PY - 2013 AN - OPUS4-29305 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Maiwald, Michael A1 - Paul, Andrea A1 - Bremser, Wolfram A1 - Bräuer, Bastian A1 - Witting, Marcus T1 - Determination of methanol in FAME by Near Infrared Spectroscopy (NIRS) and qNMR T2 - Gas 2013 Konferenz CY - Rotterdam, Netherlands DA - 2013-06-05 PY - 2013 AN - OPUS4-29306 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Maiwald, Michael T1 - 100 Jahre Prozessanalytik - Vom Pfeifenanalysator zur wissensbasierten Produktion T2 - PRORA 2013 Fachtagung Prozessnahe Röntgenanalytik CY - Berlin, Germany DA - 2013-11-21 PY - 2013 AN - OPUS4-29602 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Maiwald, Michael A1 - Zientek, Nicolai A1 - Albrecht, Marit A1 - Meyer, Klas A1 - Tröbs, L. A1 - Paul, Andrea T1 - Multi-spectroscopic approach for the analysis of dissolution profiles of pharmaceuticals T2 - EuroPACT 2014, 3rd European Conference on Process Analytics and Control Technology CY - Barcelona, Spanien DA - 2014-05-06 PY - 2014 AN - OPUS4-31889 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Maiwald, Michael A1 - Reich, O. A1 - Hass, R. T1 - "Particle size monitoring using various techniques" T2 - EuroPACT 2014, 3rd European Conference on Process Analytics and Control Technology CY - Barcelona, Spanien DA - 2014-05-06 PY - 2014 AN - OPUS4-31890 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Maiwald, Michael A1 - Zientek, Nicolai A1 - Meyer, Klas A1 - Paul, Andrea T1 - Quantitative - Online- NMR Spectroscopy: Three good arguments for a comprensive processes understanding T2 - 1. Symposium NMRPM " Quantiative NMR Methods for Reaction and Process Monitoring" CY - Kaiserslautern DA - 2015-01-15 PY - 2015 AN - OPUS4-33133 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Maiwald, Michael T1 - Die neue Technologie-Roadmap „Prozess-Sensoren 4.0“ – Chancen für neue Automationskonzepte N2 - Derzeit finden gravierende Veränderungen im Umfeld der Informations- und Kommunikationstechnik statt, die eine große Chance für die optimierte Prozessführung und Wertschöpfung mit darauf abgestimmten vernetzt kommunizierenden Sensoren bieten. Diese Art „smarte“ Sensoren stellen Dienste innerhalb eines Netzwerks bereit und nutzen Informationen daraus. Dieses ist die Voraussetzung für die Realisierung von Cyber Physical Systems (CPS) innerhalb zukünftiger Automatisierungskonzepte für die Prozessindustrie, wie sie auch durch das Zukunftsprojekt „Industrie 4.0“ adressiert werden. Initiiert von NAMUR und VDI/GMA und unter Mitwirkung der Unternehmen ABB, BASF, BTS, Bilfinger Maintenance, Endress+Hauser, Evonik, Festo, Krohne, Lanxess, Siemens, des Fraunhofer ICT, der HS Reutlingen und der BAM (Projektleitung) entstand jetzt die grundlegend aktualisierte und überarbeitete Technologie-Roadmap „Prozess-Sensoren 4.0“, die am 06. November 2015 auf der NAMUR-Hauptsitzung in Bad Neuenahr wurde. T2 - Sitzung des fms/ProcessNet-Gemeinschafts-Ausschusses „Sensoren und Sensorsysteme“ CY - Frankfurt am Main, Germany DA - 28.01.2016 KW - Roadmap KW - Prozess-Sensoren 4.0 KW - Sensoren KW - Industrie 4.0 PY - 2016 AN - OPUS4-35715 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Maiwald, Michael T1 - Die neue Technologie-Roadmap "Prozess-Sensoren 4.0" - Chancen für neue Automationskonzepte N2 - Vorstellung der neuen Technologie-Roadmap "Prozess-Sensoren 4.0" T2 - Sitzung des AMA-Wissenschaftsrates CY - Saarbrücken, Germany DA - 16.03.2016 KW - Roadmap KW - Prozess-Sensoren 4.0 KW - Sensoren KW - Industrie 4.0 PY - 2016 AN - OPUS4-35716 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Maiwald, Michael A1 - Meyer, Klas A1 - Ruiken, Jan-Paul A1 - Paul, Andrea A1 - Kern, Simon T1 - Online NMR spectroscopy as an essential tool in a multi-spectral reaction understanding approach T2 - Panle Discussion and Workshop "Reaction Monitoring with NMR Spectroscopy" SMASH 2015 CY - Baveno, Italy DA - 2015-09-24 PY - 2015 AN - OPUS4-35162 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Maiwald, Michael T1 - Die neue Technologie-Roadmap "Prozess-Sensoren 4.0" - Chancen für neue Automationskonzepte T2 - ms/ProcessNet-Gemeinschafts-Ausschuss "Sensoren und Sensorsysteme" (DECHEMA) CY - Frankfurt a. M (Germany) DA - 2016-01-28 PY - 2016 AN - OPUS4-35311 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Maiwald, Michael A1 - Pötter, Th. T1 - Einführung von Industrie 4.0 in der Prozessindustrie und Umsetzung der Technologie-Roadmap "Prozess-Sensoren 4.0" T2 - NAMUR Hauptsitzung 2015 CY - Bad Neuenahr, Germany DA - 2015-11-05 PY - 2015 AN - OPUS4-35161 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Maiwald, Michael T1 - Die neue Technologie-Roadmap "Prozess-Sensoren 4.0" T2 - 11. Kolloquium Prozessanalytik CY - Wien, Autria DA - 2015-11-30 PY - 2015 AN - OPUS4-35160 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Maiwald, Michael T1 - Clever und Smart - Die neuen Prozess-Sensoren 4.0 N2 - Die gravierenden Veränderungen im Umfeld der Informations- und Kommunikationstechnik beeinflussen auch die Prozessautomation und sind zugleich eine Chance. Denn die Automatisierungskonzepte gemäß Industrie 4.0 sichern den Wettbewerbsvorteil einer Volkswirtschaft. Ein zentrales Element bilden dabei smarte Sensoren, die Dienste innerhalb eines Netzwerks bereitstellen und Information daraus nutzen. Die im November 2015 vorgestellte Technologieroadmap Prozess-Sensoren 4.0 [1] zeigt Anforderungen an smarte Prozess-Sensoren auf. Der Beitrag befasst sich mit den Fragen „Was kann der Prozess-Sensor zu Industrie 4.0 beitragen?“ und „Welchen Nutzen bringt Industrie 4.0 für den Prozess-Sensor?“ KW - Technologieroadmap KW - Prozess-Sensoren 4.0 KW - Industrie 4.0 KW - Prozessanalytik PY - 2016 SN - 0178-2320 VL - 58 IS - 3 SP - 28 EP - 35 PB - DIV Deutscher Industrieverlag CY - München AN - OPUS4-35717 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Maiwald, Michael T1 - qNMR-Referenzmaterialien und "Indirect Hard Modeling" (IHM) als Integrationsmethode N2 - Resolving overlapping peaks of multiple components. Relative primary analytical method - Fundamental relationship of qNMR. T2 - 4. Sitzung der Next-NMR-Arbeitsgruppe CY - Karlsruhe, Germany DA - 08.12.2015 KW - qNMR KW - Quantitative NMR-Spektroskopie KW - Indirect Hard Modeling (IHM) KW - Referenzmaterialien PY - 2015 AN - OPUS4-36138 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Maiwald, Michael T1 - Die neuen Prozess-Sensoren 4.0 - Selbstdiagnose, Selbstkalibrierung und Selbstkonfiguration stehen im Fokus N2 - Heute wie morgen müssen Prozess-Sensoren zuerst die Aufgabe des Messens und der Generierung von Prozessinformationen erfüllen. Die Mess-Signale gehen in der Regel auf physikalische oder chemische Größen zurück, werden durch eine Kennlinie repräsentiert und lassen sich kalibrieren. Heute muss man dazu einen großen Aufwand betreiben, denn die physikalischen oder chemischen Informationen werden in vielen Fällen nicht direkt gemessen, sondern verbergen sich in Rohdaten, z. B. in einem optischen Spektrum. Diese Kalibrierungen können für komplexe Sensoren teilweise mehr Kostenaufwand bedeuten, als das Messgerät selbst. KW - Prozess-Sensoren KW - Prozess-Sensoren 4.0 KW - Industrie 4.0 KW - Kommunikationsstandards KW - Technologie-Roadmap PY - 2016 SN - 0947-4188 IS - 7-8 SP - 16 EP - 16 PB - Wiley-VCH Verlag GmbH & Co. KGaA AN - OPUS4-35812 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Maiwald, Michael A1 - Ostermann, Markus A1 - Schmid, Thomas T1 - Process analytical technology for resource analytics – The role of reference materials N2 - Resource Analytics with the help of process analytical technology and the use of online methods is becoming increasingly important for mining and processing technologies and for the recovery of raw materials from secondary raw materials. Current online analytical methods like laser-induced breakdown spectroscopy (LIBS), X-ray fluorescence analysis (RFA), or Raman spectroscopy for the characterization of primary and secondary raw materials are increasingly being used in close association with the technologies for exploration and extraction, mechanical and metallurgical processing, as well as for recycling. Because of the complex matrices such methods are a considerable challenge at the same time. The use of reference materials, which are derived from appropriate matrices, can considerably shorten calibration and method development times. As an example, the development of an online process control method for recovery of phosphorus from sewage sludge ashes is discussed. A combination of LIBS and RFA was developed for the determination of element contents in sewage sludge ashes and their products coming from a thermo-chemical reprocessing step, which removes pollutants. T2 - Analytica Conference CY - München, Germany DA - 10.05.2016 KW - Resource Analytics KW - Ressourcenanalytik KW - Prozessanalytik KW - Process Analytical Technology PY - 2016 AN - OPUS4-36043 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Maiwald, Michael T1 - „NMR-METRONOMIE“ Die quantitative NMR-Spektroskopie (qNMR) gibt den Takt an N2 - qNMR is a pelative primary analytical method: Overview on fundamental relationships of qNMR T2 - Festkolloquium NMR-Spektroskopie (zum 25 jährigen Jubiläum der Firma Spectral Service, Köln) CY - Köln, Germany DA - 18.09.2015 KW - qNMR KW - Quantitative NMR-Spektroskopie KW - Metrologie PY - 2015 AN - OPUS4-36140 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Maiwald, Michael T1 - qNMR metrology and "primary" references N2 - qNMR provides the most universally applicable form of direct purity determination without need for reference materials of impurities or the calculation of response factors but only exhibiting suitable NMR properties. The development of CRMs addressing qNMR specific measurement issues will give analysts compounds ideally suited for the analytical method and also provide full characterisation of qNMR related parameters to enable more realistic uncertainty budgets. These materials will give users the tools to exploit qNMR more easily and enable them to speed up analytical method development and reduce the time and financial burden of multiple analytical testing. T2 - First qNMR Foundation Meeting CY - Köln, Germany DA - 10.06.2016 KW - qNMR KW - Quantitative NMR-Spektroskopie KW - purity KW - Referenzmaterialien KW - Reference Material PY - 2016 AN - OPUS4-36450 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Maiwald, Michael A1 - Askar, Enis A1 - Günzel, Stephan A1 - Holtappels, Kai A1 - Mair, Georg A1 - Orellana Pérez, Teresa A1 - Sobol, Oded A1 - Tiebe, Carlo T1 - Competence Centre H2Safety@BAM – Safeguarding the Quality Infrastructure in the Hydrogen Economy N2 - Hydrogen is a central component of the energy transition and the European Green Deal for a climate-neutral Europe. To achieve the goals defined for 2050, the EU and the German government have developed a framework for action and are making long-term investments in research, development, and the rapid implementation of innovative hydrogen technologies. With the Competence Centre "H2Safety@BAM", BAM is creating the safety-related prerequisites for the successful implementation of hydrogen technologies at national as well as European level. To this end, BAM conducts research, testing and consulting in a holistic and inter-disciplinary manner under one roof – in the Competence Centre H2Safety@BAM. The activities of the competence centre focus on ensuring the safety of infra-structures, plants, and processes as well as innovative hydrogen transport and storage systems based on digital quality testing and the experimental testing of components and systems. It thus creates the prerequisites for the implementation and adaptation of legal framework conditions as well as for standardization. Closely related to this are investigations into the properties and compatibility of metallic materials and polymers as well as friction systems for the safe operation of components, plants, processes, and systems. This interdisciplinary and holistic approach is complemented by the development of gas analytics and suitable sensors, online measurements of gas properties in process control, test scenarios under real conditions as well as impact assessments of accidents and risk assessments and risk management systems derived from them. With its portfolio of tasks and competences, BAM builds trust in the safety and reliability of technical system solutions for hydrogen. T2 - 772. WE-Heraeus-Seminar - Metrology and Process Safety for Hydrogen Technologies & Applications CY - Bad Honnef, Germany DA - 10.10.2022 KW - H2Safety@BAM KW - Hydrogen KW - Competence Center KW - Hydrogen Strategy KW - Green Deal KW - Safety KW - Risk Assessment KW - Quality Infrastructure PY - 2022 UR - https://www.we-heraeus-stiftung.de/veranstaltungen/metrology-and-process-safety-for-hydrogen-technologies-and-applications/ AN - OPUS4-55986 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Maiwald, Michael A1 - Emmerling, Franziska A1 - Villajos Collado, José Antonio A1 - Maierhofer, Christiane A1 - Thiel, Erik A1 - Altenburg, Simon T1 - Already producing or still assembling? – Perspectives towards modular production and quality control in a digitized process industry N2 - The CLEAN ENERGY Flagship is an initiative designed to utilize recent game changing developments in digital, materials and manufacturing technologies to catalyze a radical paradigm shift towards clean, reliable, efficient and cost-optimal energy. Unifying and drastically accelerating radically new energy material design, processing and integration across the entire value chain addressing energy production, conversion, storage and systems. CLEAN ENERGY participants are all distinguished research organisations that each benefit from their own industry networks and contacts with regions and state-level activities and have a long history of collaborating with each other (for 10 years now under the umbrella of EERA) within a European collaborative framework. Through EERA, CLEAN ENERGY aims to become a crucial partner in the SET-Plan, supporting long-lasting approaches through its established networks and internal collaborations. T2 - Clean Energy Workshop on Autonomous Materials Development Platforms CY - Brussels, Belgium DA - 02.10.2018 KW - Digitization KW - Energy production KW - Energy storage KW - Energy systems KW - Clean energy technology PY - 2018 AN - OPUS4-46135 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Maiwald, Michael A1 - Bornemann-Pfeiffer, Martin A1 - Guhl, Svetlana A1 - Kern, Simon A1 - Meyer, Klas A1 - Panne, Ulrich A1 - Riedel, Jens A1 - Wander, Lukas T1 - Integrated and networked systems and processes – A perspective for digital transformation of our chemical and pharmaceutical production N2 - Chemical and pharmaceutical companies have to find new paths to survive successfully in a changing environment, while also finding more flexible ways of product and process development to bring their products to market more quickly – especially high-quality high-end products like fine chemicals or pharmaceuticals. The potential of digital technologies belongs to these. A current approach uses flexible and modular chemical production units, which can produce different high-quality products using multi-purpose equipment with short downtimes between campaigns and reduce the time to market of new products. At the same time, we need to move towards knowledge-based production that takes into account all essential equipment, process and control data from plants and laboratories and makes valuable expertise available and transferable. The potential of data from production together with its contextual information is often not yet consistently used today for a comprehensive understanding of production. By giving examples this paper outlines a possible more holistic approach to digitalisation and the use of machine-based methods in the production of specialty chemicals and pharmaceuticals through the introduction of integrated and networked systems and processes. T2 - GDCh Science Forum 2021 - GDCh Wissenschaftsforum 2021 CY - Online meeting DA - 29.08.2021 KW - Process analytical technology KW - Online NMR spectroscopy KW - Process industry KW - Industry 4.0 KW - Digital transformation KW - Autonomous chemistry PY - 2021 AN - OPUS4-53171 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Maiwald, Michael A1 - Heine, Hans-Joachim A1 - Hedrich, Martina A1 - Panne, Ulrich T1 - Referenzgase für die Analytik - zwischen Referenzmaterial und Klimawandel T2 - ANAKON 2009 CY - Berlin, Germany DA - 2009-03-17 PY - 2009 AN - OPUS4-20679 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Maiwald, Michael A1 - Kipphardt, Heinrich A1 - Tuma, Dirk A1 - Khanipour, Peyman T1 - Sensors, Analytics and Certified Reference Materials safeguarding the quality infrastructure in the hydrogen economy N2 - The prerequisites for a successful energy transition and the economic use of hydrogen as a clean green energy carrier and for H2 readiness are a rapid market ramp-up and the establishment of the required value chains. Reliable quality and safety standards for innovative technologies are the prerequisite for ensuring supply security, for environmental compatibility and sustainable climate protection, for building trust in these technologies and thus enable product and process innovations. With the Competence Centre "H2Safety@BAM", BAM is creating the safety-related prere-quisites for the successful implementation of hydrogen technologies at national as well as European level. BAM uses decades of experience in dealing with hydrogen technologies to develop the necessary quality and safety standards. The presentation will draw a bow from the typical basic tasks of BAM in the field of competence "Sensors, analytics and certified reference materials", such as maintenance and dissemination of the national gas composition standards for calorific value determination as Designated Institute for Metrology in Chemistry within the framework of the Metre Convention, to the further development of measurement and sensor technology for these tasks. For the certification of reference materials, a mostly slow and time-consuming but solid reference analysis is common. With hydrogen and its special properties, completely new requirements are added. In addition, fast and simple online analysis is required for process control, for example to register quality changes, e.g., during load changes or refuelling processes. T2 - Indo-German International Conference on Metrology for the Deployment of Green Hydrogen and Renewable Fuels in India CY - Online meeting DA - 04.04.2022 KW - Quality Infrastructure KW - Gas Reference Material KW - Hydrogen KW - Energy Gases KW - Sensors KW - Hydrogen Storage Materials PY - 2022 UR - https://www.imeko-gh2fuels.ptb.de/ AN - OPUS4-54596 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Krämer, D. A1 - Violet, N. A1 - Paul, Andrea A1 - Maiwald, Michael A1 - King, R. T1 - Robustification of partial least squares predictions based on near infrared spectroscopy trough nonlinear state estimation N2 - The Cultivation of “Saccharomyces cerevisiae” for enzyme production was monitored using Near-infrared spectroscopy. An inline NIR optrode was therefore immersed in a 15 L vessel. The calibration was done using a Partial Least Squares (PLS) model with reference measurements of glucose, ammonium, phosphate, ethanol, and optical density. A nonlinear biological process model based on an extended Kalman Filter (EKF) was used to describe the fermentation behavior. It was found that EKF corrects inaccurate PLS predictions. T2 - 11. Kolloquium Arbeitskreis Prozessanalytik CY - Wien, Austria DA - 30.11.2015 KW - PLS-R KW - Near infrared spectroscopy KW - Prozess-Spektroskopie KW - Process analytical technology KW - Fermentation PY - 2015 SP - 77 EP - 77 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-38844 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Koegler, M. A1 - Paul, Andrea A1 - Anane, E. A1 - Birkholz, M. A1 - Bunker, A. A1 - Viitala, T. A1 - Maiwald, Michael A1 - Junne, S. A1 - Neubauer, P. T1 - Comparison of time-gated surface-enhanced Raman spectroscopy (TG-SERS) and classical SERS based monitoring of Escherichia coli cultivation samples N2 - The application of Raman spectroscopy as a monitoring technique for bioprocesses is severely limited by a large background signal originating from fluorescing compounds in the culture media. Here, we compare time-gated Raman (TG-Raman)-, continuous wave NIRprocess Raman (NIR-Raman), and continuous wave micro-Raman (micro-Raman) approaches in combination with surface enhanced Raman spectroscopy (SERS) for their potential to overcome this limit. For that purpose, we monitored metabolite concentrations of Escherichia coli bioreactor cultivations in cell-free supernatant samples. We investigated concentration transients of glucose, acetate, AMP, and cAMP at alternating substrate availability, from deficiency to excess. Raman and SERS signals were compared to off-line metabolite analysis of carbohydrates, carboxylic acids, and nucleotides. Results demonstrate that SERS, in almost all cases, led to a higher number of identifiable signals and better resolved spectra. Spectra derived from the TG-Raman were comparable to those of micro-Raman resulting in well-discernable Raman peaks, which allowed for the identification of a higher number of compounds. In contrast, NIR-Raman provided a superior performance for the quantitative evaluation of analytes, both with and without SERS nanoparticles when using multivariate data analysis. KW - Time-gated Raman (TG-Raman) KW - Surface-enhanced Raman spectroscopy (SERS) KW - Multivariate data analysis KW - Metabolite quantification KW - Escherichia coli PY - 2018 DO - https://doi.org/10.1002/btpr.2665 SN - 1520-6033 SN - 8756-7938 VL - 34 IS - 6 SP - 1533 EP - 1542 PB - Wiley AN - OPUS4-45831 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kloska, M. A1 - Maiwald, Michael T1 - Scharfe Überwachung der Zusammensetzung - Die Prozessanalysentechnik (PAT) feiert in diesem Jahr 100. Geburtstag N2 - Vor 100 Jahren, am 22. Mai 1913, erhielt Dr. Paul Gmelin, Mitarbeiter im physikalischen Laboratorium der Badischen Anilin und Soda Fabrik in Ludwigshafen das erste Patent auf ein Prozessanalysenmessgerät. Dieses Jubiläum würdigt CITplus mit diesem Beitrag, in dem die Autoren nicht nur die vergangene sondern auch eine mögliche künftige Entwicklung der Prozessanalysentechnik (PAT) Revue passieren lassen. PY - 2013 SN - 1436-2597 SN - 1439-0663 VL - 16 IS - 11 SP - 6 EP - 8 PB - GIT-Verl., Wiley-VCH CY - Weinheim AN - OPUS4-29600 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kipphardt, Heinrich A1 - Tuma, Dirk A1 - Khanipour, Peyman A1 - Maiwald, Michael T1 - Voll normal - Normen in der Gasanalytik N2 - In dieser Arbeit werden die Grundlagen der Normung, die Entstehung einer Norm und die für die Gasanalytik relevanten Normungsgremien kurz dargestellt. Dazu werden die wichtigsten Normen zur Gasanalytik entlang des analytischen Prozesses gruppiert und aufgeführt. Schließlich wird als Anwendungsbeispiel aus der eigenen Praxis der Prozess von der Herstellung bis zur Zertifizierung eines Kalibriergases beschrieben. KW - Zertifikat KW - Regel- und Messtechnik KW - Normung KW - Gasanalytik KW - Gasgualität KW - Gasreinheit PY - 2022 SN - 2366-9594 VL - 10 SP - 73 EP - 80 PB - Vulkan Verlag CY - Essen AN - OPUS4-56083 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CHAP A1 - Kessler, R. W. A1 - Kessler, W. A1 - Maiwald, Michael ED - Meyers, R. A. T1 - Inline and Online Process Analytical Technology with a Focus on Optical Spectroscopy N2 - Process analytical technology (PAT) is a cross-sectional technology and thus essential for future smart production. While in the past decades, the focus of process optimization strategies was on increasing efficiency, in the future, the focus will be on the sustainability of a production and its products. In addition, products will be increasingly personalized in order to match the property profile exactly to the intended use. PAT is able to provide context-sensitive information at the molecular level for process control. Spectroscopic sensors can determine inline and simultaneously both the chemical composition and its sub-microscopic morphology. The article will focus on the optical spectroscopy and therefore starts with a brief introduction on the basic concepts of molecular spectroscopy. In addition, the particularities of measuring liquids, surfaces, or particulate systems in PAT applications are described. This should enable the reader to select the appropriate method for the specific problem. Many examples from everyday industrial practice illustrate the applications. The areas covered are the manufacturing industry, process and pharmaceutical industry, food industry, as well as biotechnology and medical technology. Future will show that PAT is especially important for applications in the field of medicine (point of care) circular economy (recycling, water–wastewater, etc.). It is important to emphasize that sustainability in industrial production can only be successful with an inter- and transdisciplinary close exchange between the different disciplines. KW - Process Analytical Technology KW - Optical Spectroscopy KW - Encyclopedia of Analytical Chemistry KW - Sensors KW - Process Industry PY - 2022 SN - 978-0-47002-731-8 DO - https://doi.org/10.1002/9780470027318.a9791 SP - 1 EP - 31 PB - JohnWiley & Sons, Ltd. AN - OPUS4-56688 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kern, Simon A1 - Wander, Lukas A1 - Meyer, Klas A1 - Guhl, Svetlana A1 - Gottu Mukkula, A. R. A1 - Holtkamp, M. A1 - Salge, M. A1 - Fleischer, C. A1 - Weber, N. A1 - King, R. A1 - Engell, S. A1 - Paul, Andrea A1 - Pereira Remelhe, M. A1 - Maiwald, Michael T1 - Flexible Automation with compact NMR instruments N2 - Modular plants using intensified continuous processes represent an appealing concept to produce pharmaceuticals. It can improve quality, safety, sustainability, and profitability compared to batch processes, and it enables plug-and-produce reconfiguration for fast product changes. To facilitate this flexibility by real-time quality control, we developed a solution that can be adapted quickly to new processes and includes a compact Nuclear Magnetic Resonance (NMR) spectrometer for online quality monitoring as well as a new model-based control approach. The NMR sensor is a benchtop device enhanced to the requirements of automated chemical production including ro-bust evaluation of sensor data. Here, we present alternatives for the quantitative determination of the analytes using modular, physically motivated models. These models can be adapted to new substances solely by the use of their corresponding pure component spectra, which can either be derived from experimental spectra as well as from quantum mechanical models or NMR predictors. Modular means that spec-tral models can simply be exchanged together with alternate reagents and products. Beyond that, we comprehensively calibrated an NIR spectrometer based on online NMR process data for the first time within an industrial plant. The integrated solution was developed for a metal organic reac-tion running on a commercial-scale modular pilot plant and it was tested under industrial conditions. T2 - 7th Annual PANIC Conference CY - Hilton Head Island, South Carolina, USA DA - 03.03.2019 KW - Online NMR Spectroscopy PY - 2019 AN - OPUS4-47715 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kern, Simon A1 - Wander, Lukas A1 - Meyer, Klas A1 - Guhl, Svetlana A1 - Gottu Mukkula, A. R. A1 - Holtkamp, M. A1 - Salge, M. A1 - Fleischer, C. A1 - Weber, N. A1 - Engell, S. A1 - Paul, Andrea A1 - Pereira Remelhe, M. A1 - Maiwald, Michael T1 - Flexible automation with compact NMR spectroscopy for continuous production of pharmaceuticals N2 - Modular plants using intensified continuous processes represent an appealing concept for the production of pharmaceuticals. It can improve quality, safety, sustainability, and profitability compared to batch processes; besides, it enables plug-and-produce reconfiguration for fast product changes. To facilitate this flexibility by real-time quality control, we developed a solution that can be adapted quickly to new processes and is based on a compact nuclear magnetic resonance (NMR) spectrometer. The NMR sensor is a benchtop device enhanced to the requirements of automated chemical production including robust evaluation of sensor data. Beyond monitoring the product quality, online NMR data was used in a new iterative optimization approach to maximize the plant profit and served as a reliable reference for the calibration of a near-infrared (NIR) spectrometer. The overall approach was demonstrated on a commercial-scale pilot plant using a metal-organic reaction with pharmaceutical relevance. KW - NMR Spectroscopy KW - NIR Spectroscopy KW - Real-time process monitoring KW - Real-time quality control KW - Continuous processes KW - CONSENS KW - Data Fusion PY - 2019 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-480623 DO - https://doi.org/10.1007/s00216-019-01752-y SN - 1618-2642 SN - 1618-2650 VL - 411 IS - 14 SP - 3037 EP - 3046 PB - Springer Nature CY - Heidelberg AN - OPUS4-48062 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Kern, Simon A1 - Wander, Lukas A1 - Meyer, Klas A1 - Guhl, Svetlana A1 - Gottu Mukkula, A. R. A1 - Holtkamp, M. A1 - Salge, M. A1 - Fleischer, C. A1 - Weber, N. A1 - Engell, S. A1 - Paul, Andrea A1 - King, R. A1 - Maiwald, Michael T1 - Raw data of pilot plant runs for CONSENS project (Case study 1) N2 - In case study one of the CONSENS project, two aromatic substances were coupled by a lithiation reaction, which is a prominent example in pharmaceutical industry. The two aromatic reactants (Aniline and o-FNB) were mixed with Lithium-base (LiHMDS) in a continuous modular plant to produce the desired product (Li-NDPA) and a salt (LiF). The salt precipitates which leads to the formation of particles. The feed streams were subject to variation to drive the plant to its optimum. The uploaded data comprises the results from four days during continuous plant operation time. Each day is denoted from day 1-4 and represents the dates 2017-09-26, 2017-09-28, 2017-10-10, 2017-10-17. In the following the contents of the files are explained. KW - Process Analytical Technology KW - Multivariate Data Analysis KW - Nuclear Magnetic Resonance KW - Near Infrared Spectroscopy KW - Continuous Manufacturing KW - CONSENS PY - 2018 DO - https://doi.org/10.5281/zenodo.1438233 PB - Zenodo CY - Geneva AN - OPUS4-48063 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kern, Simon A1 - Michalik-Onichimowska, Aleksandra A1 - Riedel, Jens A1 - Panne, Ulrich A1 - King, Rudibert A1 - Maiwald, Michael ED - Maiwald, Michael T1 - “Click” analytics for “click” chemistry – a simple method for calibration-free evaluation of online NMR spectra N2 - Currently research in chemical manufacturing moves towards flexible plug-and-play approaches focusing on modular plants, capable of producing small scales on-demand with short down-times between individual cam-paigns. This approach allows for efficient use of hardware, a faster optimization of the process conditions, and thus, an accelerated introduction of new products to the market. Driven mostly by the search for chemical syntheses under biocompatible conditions, so-called “click” chemistry rapidly became a growing field of research. The re-sulting simple one-pot reactions are so far only scarcely accompanied by an adequate optimization via compara-bly straightforward and robust analysis techniques. Here we report on a fast and reliable calibration-free online high field NMR monitoring approach for technical mixtures. It combines a versatile fluidic system, continuous-flow measurement with a time interval of 20 s per spectrum, and a robust, automated algo-rithm to interpret the ob-tained data. All spectra were acquired using a 500 MHz NMR spectrometer (Varian) with a dual band flow probe having a 1/16 inch polymer tubing working as a flow cell. Single scan 1H spectra were recorded with an acquisition time of 5 s, relaxation delay of 15 s. T2 - 12. Kolloquium des Arbeitskreises Prozessanalytik CY - Berlin, Germany DA - 28.11.2016 KW - “Click” chemistry KW - Online NMR KW - Online monitoring PY - 2016 SP - 72 EP - 74 AN - OPUS4-38385 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kern, Simon A1 - Michalik-Onichimowska, Aleksandra A1 - Riedel, Jens A1 - Panne, Ulrich A1 - King, R. A1 - Maiwald, Michael T1 - “Click” analytics for “click” chemistry – a simple method for calibration-free evaluation of online NMR spectra N2 - Currently research in chemical manufacturing moves towards flexible plug-and-play approaches focusing on modular plants, capable of producing small scales ondemand with short down-times between individual campaigns. This approach allows for efficient use of hardware, a faster optimization of the process conditions, and thus, an accelerated introduction of new products to the market. Driven mostly by the search for chemical syntheses under biocompatible conditions, so-called “click” chemistry rapidly became a growing field of research. The resulting simple one-pot reactions are so far only scarcely accompanied by an adequate optimization via comparably straightforward and robust analysis techniques. Here we report on a fast and reliable calibration-free online high field NMR monitoring approach for technical mixtures. It combines a versatile fluidic system, continuous-flow measurement with a time interval of 20 s per spectrum, and a robust, automated algorithm to interpret the obtained data. All spectra were acquired using a 500 MHz NMR spectrometer (Varian) with a dual band flow probe having a 1/16 inch polymer tubing working as a flow cell. Single scan 1H spectra were recorded with an acquisition time of 5 s, relaxation delay of 15 s. As a proof-of-concept, the thiol-ene coupling between N-boc cysteine methyl ester and allyl alcohol was conducted in non-deuterated solvents while its time-resolved behaviour was characterised with step tracer experiments Through the application of spectral modeling the signal area for each reactant can be deconvoluted in the online spectra and thus converted to the respective concentrations or molar ratios. The signals which were suitable for direct integration were used herein for comparison purposes of both methods. T2 - 4th European Conference on Process Analytics and Control Technology (EuroPACT 2017) CY - Potsdam, Germany DA - 10.05.2017 KW - Online NMR Spectroscopy KW - Process Analytical Technology KW - Click Chemistry KW - Reaction Monitoring KW - Process control KW - Indirect Hard Modeling KW - Spectral Modeling PY - 2017 SP - 156 EP - 157 CY - Frankfurt a. M. AN - OPUS4-40232 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kern, Simon A1 - Michalik-Onichimowska, Aleksandra A1 - Riedel, Jens A1 - Panne, Ulrich A1 - King, R. A1 - Maiwald, Michael ED - Herwig, Christoph T1 - “Click” analytics for “click” chemistry – a simple method for calibration-free evaluation of online NMR spectra N2 - Currently, research in chemical manufacturing moves towards flexible plug-and-play approaches focusing on modular plants, capable of producing small scales on-demand with short down-times between individual campaigns. This approach allows for efficient use of hardware, a faster optimization of the process conditions, and thus, an accelerated introduction of new products to the market. Driven mostly by the search for chemical syntheses under biocompatible conditions, so-called “click” chemistry rapidly became a growing field of research. The resulting simple one-pot reactions are so far only scarcely accompanied by an adequate optimization via comparably straightforward and robust analysis techniques. Here we report on a fast and reliable calibration-free online high field NMR monitoring approach for technical mixtures. It combines a versatile fluidic system, continuous-flow measurement with a time interval of 20 s per spectrum, and a robust, automated algorithm to interpret the obtained data. All spectra were acquired using a 500 MHz NMR spectrometer (Varian) with a dual band flow probe having a 1/16-inch polymer tubing working as a flow cell. Single scan 1H NMR spectra were recorded with an acquisition time of 5 s, relaxation delay of 15 s. As a proof-of-concept, the thiol-ene coupling between N-boc cysteine methyl ester and allyl alcohol was conducted in non-deuterated solvents while its time-resolved behaviour was characterised with step tracer experiments. Through the application of spectral modeling the signal area for each reactant can be deconvoluted in the online spectra and thus converted to the respective concentrations or molar ratios. The signals which were suitable for direct integration were used herein for comparison purposes of both methods. T2 - 11. Interdisziplinäres Doktorandenseminar CY - Berlin, Germany DA - 12.03.2017 KW - Process Monitoring KW - Online NMR Spectroscopy KW - Indirect Hard Modeling KW - Process Control KW - Process Analytical Technology KW - CONSENS KW - Click Chemistry PY - 2017 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-435531 SP - 33 EP - 35 PB - Gesellschaft Deutscher Chemiker (GDCh) CY - Frankfurt a. M. AN - OPUS4-43553 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kern, Simon A1 - Meyer, Klas A1 - Paul, Andrea A1 - Maiwald, Michael T1 - Ugly Spectra and Lousy interfaces – Challenges for Compact NMR Spectroscopy in Process Control N2 - With the introduction of advanced process analytical technology, the closeness of key process variables to their limits can be directly controlled and the product can be classified or even released in real time. Compact NMR instruments can make NMR spectroscopy accessible in industrial and harsh environments for process control. T2 - ProcessNet-Jahrestagung und 32. DECHEMA-Jahrestagung der Biotechnologen 2016 CY - Aachen, Germany DA - 12.09.2016 KW - Online NMR Spectroscopy KW - Smart Sensors KW - Industrie 4.0 KW - Reaction Monitoring PY - 2016 UR - http://onlinelibrary.wiley.com/doi/10.1002/cite.201650243/full DO - https://doi.org/10.1002/cite.201650243 SN - 1522-2640 VL - 88 SP - 1304 EP - 1317 PB - Wiley-VCH Verlag GmbH & Co. KGaA CY - Weinheim AN - OPUS4-37317 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kern, Simon A1 - Meyer, Klas A1 - Maiwald, Michael T1 - NMR-Spektroskopie im Feld - Eine neue Online-Methode für die Prozesskontrolle N2 - Flexible, modulare Produktionsanlagen auf der Basis von verfahrenstechnischen Teilmodulen stellen einen vielversprechenden Ansatz für die kontinuierliche Produktion von Fein- und Spezialchemikalien dar. Der Schwerpunkt des Horizont-2020-Projekts der Europäischen Kommission CONSENS (Integrated Control and Sensing) liegt in der Implementierung von innovativen Sensorkonzepten zur Prozessüberwachung und -regelung innerhalb von containerbasierten modularen Produktionsan lagen. In diesem Artikel wird die Feldintegration eines Online-NMR-Sensors als smartes Modul für die Prozesskontrolle beschrieben. Dieses Modul basiert auf einem kommerziell erhältlichen Niederfeld-NMRSpektrometer, das zurzeit für die Anwendung im Laborbereich erhältlich ist. Für die Feldintegration wurde ein ATEX-zertifiziertes, explosionsgeschütztes Gehäuse entwickelt sowie Automationsschemen für den unbeaufsichtigten Betrieb und für die spektrale Datenauswertung erstellt. Nachdem die Machbarkeit und Leistungsfähigkeit des Sensorkonzeptes in Laborexperimente an einer aromatischen Substitutionsreaktion bereits erfolgreich demonstriert wurde, ist die Inbetriebnahme des NMR-Sensormoduls in industrieller Umgebung für 2017 geplant. KW - Prozessanalytik KW - Reaction monitoring KW - Industrie 4.0 KW - Online-NMR-Spektroskopie KW - CONSENS KW - Prozess-Sensoren PY - 2016 SN - 2190-4111 VL - 58 IS - 12 SP - 21 EP - 25 PB - DIV Deutscher Industrieverlag GmbH CY - München AN - OPUS4-38675 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kern, Simon A1 - Meyer, Klas A1 - Guhl, Svetlana A1 - Gräßer, Patrick A1 - Paul, Andrea A1 - King, R. A1 - Maiwald, Michael T1 - Online low-field NMR spectroscopy for process control of an industrial lithiation reaction—automated data analysis N2 - Monitoring specific chemical properties is the key to chemical process control. Today, mainly optical online methods are applied, which require time- and cost-intensive calibration effort. NMR spectroscopy, with its advantage being a direct comparison method without need for calibration, has a high potential for closed-loop process control while exhibiting short set-up times. Compact NMR instruments make NMR spectroscopy accessible in industrial and rough environments for process monitoring and advanced process control strategies. We present a fully automated data analysis approach which is completely based on physically motivated spectral models as first principles information (Indirect Hard Modelling – IHM) and applied it to a given pharmaceutical lithiation reaction in the framework of the European Union’s Horizon 2020 project CONSENS. Online low-field NMR (LF NMR) data was analysed by IHM with low calibration effort, compared to a multivariate PLS-R (Partial Least Squares Regression) approach, and both validated using online high-field NMR (HF NMR) spectroscopy. KW - Online NMR spectroscopy KW - Process analytical technology KW - Partial Least Squares Regression KW - Indirect Hard Modeling KW - Benchtop NMR Spectroscopy KW - Smart Sensors KW - CONSENS PY - 2018 UR - https://link.springer.com/article/10.1007/s00216-018-1020-z DO - https://doi.org/10.1007/s00216-018-1020-z SN - 1618-2642 SN - 1618-2650 VL - 410 IS - 14 SP - 3349 EP - 3360 PB - Springer CY - Berlin, Heidelberg AN - OPUS4-44847 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kern, Simon A1 - Maiwald, Michael T1 - Low field NMR spectroscopy for process control - robust automated data preparation and analysis as prerequisites T1 - Niederfeld NMR-Spektroskopie für die Prozesskontrolle – Robuste und automatisierte Datenvorbehandlung und Datenanalyse als Grundvoraussetzungen N2 - Berichtet wird über die automatisierte und spektral-modellgestützte Datenauswertung quantitativer Online-NMR-Spektren von technischen Systemen, die einen grundlegenden Beitrag zum Thematik Smart Sensors im Sinne kalibrierarmer bzw. kalibrierfreier Verfahren liefern. Die quantitative Online-NMR-Spektroskopie ist besonders reizvoll für diese Thematik: Sie kommt durch den direkten Nachweis der Kernspins ohne Kalibrierung aus und arbeitet auch in Konzentrationsrandbereichen äußerst linear. Als „absolute Vergleichsmethode“ (direkte Proportionalität der Signale zu den Stoffmengen innerhalb eines Spektrums) ist die NMR-Spektroskopie für die durchgeführten Grundlagenuntersuchungen im Zusammenhang mit spektralen Modellen prädestiniert. T2 - Seminar des Institut für Mathematik, Universität Rostock CY - Rostock, Germany DA - 12.07.2017 KW - Prozessanalytik KW - Prozess-Sensoren 4.0 KW - Online NMR Spektroskopie KW - Indirect Hard Modeling PY - 2017 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-409694 AN - OPUS4-40969 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kern, Simon A1 - Liehr, Sascha A1 - Wander, Lukas A1 - Bornemann-Pfeiffer, Martin A1 - Müller, S. A1 - Maiwald, Michael A1 - Kowarik, Stefan T1 - Artificial neural networks for quantitative online NMR spectroscopy N2 - Industry 4.0 is all about interconnectivity, sensor-enhanced process control, and data-driven systems. Process analytical technology (PAT) such as online nuclear magnetic resonance (NMR) spectroscopy is gaining in importance, as it increasingly contributes to automation and digitalization in production. In many cases up to now, however, a classical evaluation of process data and their transformation into knowledge is not possible or not economical due to the insufficiently large datasets available. When developing an automated method applicable in process control, sometimes only the basic data of a limited number of batch tests from typical product and process development campaigns are available. However, these datasets are not large enough for training machine-supported procedures. In this work, to overcome this limitation, a new procedure was developed, which allows physically motivated multiplication of the available reference data in order to obtain a sufficiently large dataset for training machine learning algorithms. The underlying example chemical synthesis was measured and analyzed with both application-relevant low-field NMR and high-field NMR spectroscopy as reference method. Artificial neural networks (ANNs) have the potential to infer valuable process information already from relatively limited input data. However, in order to predict the concentration at complex conditions (many reactants and wide concentration ranges), larger ANNs and, therefore, a larger Training dataset are required. We demonstrate that a moderately complex problem with four reactants can be addressed using ANNs in combination with the presented PAT method (low-field NMR) and with the proposed approach to generate meaningful training data. KW - Online NMR spectroscopy KW - Real-time process monitoring KW - Artificial neural networks KW - Automation KW - Process industry PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-507508 DO - https://doi.org/10.1007/s00216-020-02687-5 SN - 1618-2642 VL - 412 IS - 18 SP - 4447 EP - 4459 PB - Springer CY - Berlin AN - OPUS4-50750 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Kern, Simon A1 - Liehr, Sascha A1 - Wander, Lukas A1 - Bornemann-Pfeiffer, Martin A1 - Müller, S. A1 - Maiwald, Michael A1 - Kowarik, Stefan T1 - Training data of quantitative online NMR spectroscopy for artificial neural networks N2 - Data set of low-field NMR spectra of continuous synthesis of nitro-4’-methyldiphenylamine (MNDPA). 1H spectra (43 MHz) were recorded as single scans. Two different approaches for the generation of artificial neural networks training data for the prediction of reactant concentrations were used: (i) Training data based on combinations of measured pure component spectra and (ii) Training data based on a spectral model. Synthetic low-field NMR spectra First 4 columns in MAT-files represent component areas of each reactant within the synthetic mixture spectrum. Xi (“pure component spectra dataset”) Xii (“spectral model dataset”) Experimental low-field NMR spectra from MNDPA-Synthesis This data set represents low-field NMR-spectra recorded during continuous synthesis of nitro-4’-methyldiphenylamine (MNDPA). Reference values from high-field NMR results are included. KW - NMR spectroscopy KW - Real-time process monitoring KW - Artificial neural networks KW - Online NMR spectroscopy KW - Automation KW - Process industry PY - 2020 DO - https://doi.org/10.5281/zenodo.3677139 PB - Zenodo CY - Geneva AN - OPUS4-50456 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kern, Simon A1 - Guhl, Svetlana A1 - Meyer, Klas A1 - Wander, Lukas A1 - Paul, Andrea A1 - Maiwald, Michael T1 - Mathematical and statistical tools for online NMR spectroscopy in chemical processes N2 - Monitoring chemical reactions is the key to chemical process control. Today, mainly optical online methods are applied, which require excessive calibration effort. NMR spectroscopy has a high potential for direct loop process control while exhibiting short set-up times. Compact NMR instruments make NMR spectroscopy accessible in industrial and harsh environments for advanced process Monitoring and control, as demonstrated within the European Union’s Horizon 2020 project CONSENS. We present a range of approaches for the automated spectra analysis moving from conventional multivariate statistical approach, (i.e., Partial Least Squares Regression) to physically motivated spectral models (i.e., Indirect Hard Modelling and Quantum Mechanical calculations). By using the benefits of traditional qNMR experiments data analysis models can meet the demands of the PAT community (Process Analytical Technology) regarding low calibration effort/calibration free methods, fast adaptions for new reactants or derivatives and robust automation schemes. T2 - 13. Dresdner Sensor Symposium CY - Dresden, Germany DA - 04.12.2017 KW - Online NMR spectroscopy KW - Process control KW - Partial least squares regression KW - Indirect hard modeling KW - Quantum mechanics KW - First principles PY - 2017 UR - https://www.ama-science.org/proceedings/details/2748 SN - 978-3-9816876-5-1 DO - https://doi.org/10.5162/13dss2017/P2.07 SP - P2, 209 EP - 212 PB - AMA Service GmbH CY - Berlin AN - OPUS4-43254 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kern, Simon A1 - Guhl, Svetlana A1 - Meyer, Klas A1 - Wander, Lukas A1 - Paul, Andrea A1 - Bremser, Wolfram A1 - Maiwald, Michael T1 - Mathematical and statistical tools for online NMR spectroscopy in chemical processes N2 - Monitoring chemical reactions is the key to chemical process control. Today, mainly optical online methods are applied, which require excessive calibration effort. NMR spectroscopy has a high potential for direct loop process control while exhibiting short set-up times. Compact NMR instruments make NMR spectroscopy accessible in industrial and harsh environ¬ments for advanced process monitoring and control, as demonstrated within the European Union’s Horizon 2020 project CONSENS. We present a range of approaches for the automated spectra analysis moving from conventional multivariate statistical approach, (i.e., Partial Least Squares Regression) to physically motivated spectral models (i.e., Indirect Hard Modelling and Quantum Mechanical calculations). By using the benefits of traditional qNMR experiments data analysis models can meet the demands of the PAT community (Process Analytical Technology) regarding low calibration effort/calibration free methods, fast adaptions for new reactants or derivatives and robust automation schemes. T2 - Advanced Mathematical and Computational Tools in Metrology and Testing conference CY - Glasgow, United Kingdom DA - 29.08.2017 KW - Online NMR Spectroscopy KW - Process Control KW - Partial Least Squares Regression KW - Indirect Hard Modelling KW - Quantum Mechanics KW - First Principles PY - 2018 SN - 978-9-813-27429-7 VL - 89 SP - 229 EP - 234 PB - World Scientific CY - New Jersey AN - OPUS4-51391 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kern, Simon A1 - Guhl, Svetlana A1 - Meyer, Klas A1 - Paul, Andrea A1 - Wander, Lukas A1 - Gräßer, Patrick A1 - Maiwald, Michael T1 - Design and Validation of a Compact NMR Analyser N2 - Monitoring chemical reactions is the key to chemical process control. Today, mainly optical online methods are applied. NMR spectroscopy has a high potential for direct loop process control. Compact NMR instruments based on permanent magnets are robust and relatively inexpensive analysers, which feature advantages like low cost, low maintenance, ease of use, and cryogen-free operation. Instruments for online NMR measurements equipped with a flow-through cell, possessing a good signal-to-noise-ratio, sufficient robustness, and meeting the requirements for integration into industrial plants (i.e., explosion safety and fully automated data analysis) are currently not available off the rack. Intensified continuous processes are in focus of current research. Flexible (modular) chemical plants can produce different products using the same equipment with short down-times between campaigns and quick introduction of new products to the market. In continuous flow processes online sensor data and tight closed-loop control of the product quality are mandatory. If these are not available, there is a huge risk of producing large amounts of out-of-spec (OOS) products. This is addressed in the European Unionʼs Research Project CONSENS (Integrated Control and Sensing) by development and integration of smart sensor modules for process monitoring and control within such modular plant setups. The presented NMR module is provided in an explosion proof housing of 57 x 57 x 85 cm module size and involves a compact 43.5 MHz NMR spectrometer together with an acquisition unit and a programmable logic controller for automated data preparation (phasing, baseline correction) and evaluation. Indirect Hard Modeling (IHM) was selected for data analysis of the low-field NMR spectra. A set-up for monitoring continuous reactions in a thermostated 1/8” tubular reactor using automated syringe pumps was used to validate the IHM models by using high-field NMR spectroscopy as analytical reference method. T2 - 4th European Conference on Process Analytics and Control Technology (EuroPACT 2017) CY - Potsdam, Germany DA - 10.05.2017 KW - Prozessanalytik KW - Reaction Monitoring KW - Online NMR Spectrsocopy KW - Process Analytical Technology KW - Industrie 4.0 KW - EuroPACT PY - 2017 SP - 72 EP - 73 CY - Frankfurt a. M. AN - OPUS4-40229 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Kern, Simon A1 - Guhl, Svetlana A1 - Meyer, Klas A1 - Maiwald, Michael ED - Maiwald, Michael T1 - Validation report on NMR N2 - The departure from the current automation landscape to next generation automation concepts for the process industry has already begun. Smart functions of sensors simplify their use and enable plug and play integration, even though they may appear to be more complex at first sight. Smart sensors enable concepts like self-diagnostics, self-calibration, and self-configuration/ parameterization whenever our current automation landscape allows it. Here we summarize the currently discussed general requirements for process sensors 4.0 and introduce a smart online NMR sensor module as example, which was developed for an intensified industrial process funded by the EU’s Horizon 2020 research and innovation programme (www.consensspire.eu). KW - Process Monitoring KW - Online NMR Spectroscopy KW - Indirect Hard Modeling KW - Process Control KW - Process Analytical Technology KW - CONSENS PY - 2017 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-435521 SP - 1 EP - 31 AN - OPUS4-43552 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kern, Simon A1 - Gräßer, Patrick A1 - Zientek, Nicolai A1 - Maiwald, Michael T1 - First steps towards field integration of benchtop NMR spectroscopy for online monitoring and process control N2 - Online monitoring and process control requires fast and noninvasive analytical methods, which are able to monitor the concentration of reactants in multicomponent mixtures with parts-per-million resolution. Online NMR spectros-copy can meet these demands when flow probes are directly coupled to reactors, since this method features a high linearity between absolute signal area and sample concentration, which makes it an absolute analytical com-parison method being independent on the matrix. Due to improved magnet design and field shimming strategies portable and robust instruments have been introduced to the market by several manufacturers during the last few years. First studies with this technology showed promising results to monitor chemical reaction in the laboratory. T2 - 11. Kolloquium Arbeitskreis Prozessanalytik CY - Wien, Austria DA - 30.11.2015 KW - Online NMR Spectroscopy KW - Smart Sensors KW - Prozess-Spektroskopie KW - Process Analytical Technology KW - Process control PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-388411 SP - 43 EP - 44 AN - OPUS4-38841 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Jacobasch, Stefan A1 - Duffner, Eric A1 - Goedecke, Thomas A1 - Portella, Pedro Dolabella A1 - Mair, Georg A1 - Schendler, Thomas A1 - Gradt, Thomas A1 - Askar, Enis A1 - Bartholmai, Matthias A1 - Schröder, Volkmar A1 - Maiwald, Michael A1 - Holtappels, Kai A1 - Tschirschwitz, Rico A1 - Neumann, Patrick P. T1 - Unser Beitrag zum Thema Wasserstoff N2 - Die BAM ist nahezu über die gesamte Wertschöpfungskette hinweg wissenschaftlich tätig. Von der sicheren und effizienten Wasserstofferzeugung (POWER-to-GAS), über die (Zwischen-)Speicherung von Wasserstoff in Druckgasspeichern bis hin zum Transport bspw. mittels Trailerfahrzeug zum Endverbraucher. Komplettiert werden die Aktivitäten der BAM durch die sicherheitstechnische Beurteilung von wasserstoffhaltigen Gasgemischen, die Verträglichkeitsbewertung von Werkstoffen bis hin zur Detektion von Wasserstoffkonzentrationen über geeignete Sensorik, auch mittels ferngesteuerter Messdrohnen (sog. UAV-Drohnen). Zudem untersucht die BAM proaktiv Schadensrisiken und Unfallszenarien für die Sicherheitsbetrachtung, um mögliche Schwachstellen aufzeigen und potenzielle Gefährdungen erkennen zu können. KW - Wasserstoff KW - Wasserstofferzeugung KW - Energiespeicherung KW - Gasdetektion KW - Risikoanalyse KW - Power-to-Gas KW - Explosionsschutz KW - Tribologie KW - Druckgasspeicher KW - Glasspeicher KW - Gassensorik KW - Mini-UAV PY - 2019 SP - 1 CY - Berlin AN - OPUS4-47960 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Illner, M. A1 - Meyer, Klas A1 - Paul, Andrea A1 - Esche, E. A1 - Maiwald, Michael A1 - Repke, J.-U. T1 - Operation and Optimal Control of Multiphase Systems – Hydroformylation in Microemulsions on the Mini-plant Scale N2 - Hydroformylation of short-chained olefins has been established as a standard industrial process for the production of C2 to C6 aldehydes. Using aqueous solutions of transition metal complexes these processes are carried out homogeneously catalyzed. A biphasic approach allows for highly efficient catalyst recovery. Regarding renewable feedstocks, the hydroformylation of long-chained alkenes (> C10) in a biphasic system, using highly selective rhodium catalysts has yet not been shown. Therefore, the Collaborative Research Center SFB/TR 63 InPROMPT develops new process concepts, involving innovative tuneable solvent systems to enable rather difficult or so far nonviable synthesis paths. One possible concept is the hydroformylation of long-chained alkenes in microemulsions. For this, a modular mixer-settler concept was proposed, combining high reaction rates and efficient catalyst recycling via the application of technical grade surfactants. The feasibility of such a concept is evaluated in a fully automated, modular mini-plant system within which the characteristics of such a multiphase system pose several obstacles for the operation. Maintaining a stable phase separation for efficient product separation and catalyst recycling is complicated by small and highly dynamic operation windows as well as poor measurability of component concentrations in the liquid phases. In this contribution, a model-based strategy is presented to enable concentration tracking and phase state control within dynamic mini-plant experiments. Raman spectroscopy is used as an advanced process analytical tool, which allows for online in-situ tracking of concentrations. Combined with optical and conductivity analysis optimal plant trajectories can be calculated via the solution of dynamic optimization problem under uncertainty. Applying these, a stable reaction yield of 40 % was achieved, combined with an oil phase purity of 99,8 % (total amount of oily components in the oil phase) and catalyst leaching below 0.1 ppm. T2 - 4th European Conference on Process Analytics and Control Technology (EuroPACT 2017) CY - Potsdam, Germany DA - 10.05.2017 KW - Hydroformylation KW - Micoemulsion KW - Dispersion KW - Process Analytical Technology KW - Mini-plant KW - EuroPACT PY - 2017 SP - 92 EP - 92 CY - Frankfurt a. M. AN - OPUS4-40230 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hergeth, W.-D. A1 - Maiwald, Michael T1 - Trends in der Prozessanalytik: Von der Forschung zur industriellen Anwendung KW - Prozessanalytik KW - Produktqualität PY - 2009 DO - https://doi.org/10.1002/cite.200950241 SN - 0009-286X SN - 1522-2640 VL - 81 IS - 8 SP - 1098 EP - 1099 PB - Wiley-VCH Verl. CY - Weinheim AN - OPUS4-20258 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hergeth, W.-D. A1 - Maiwald, Michael T1 - Trends in der Prozessanalytik - Von der Forschung zur industriellen Anwendung KW - Prozessanalytik KW - Sensoren KW - Polymerisation KW - Raman-Spektroskopie PY - 2009 SN - 0947-4188 IS - 22 SP - 16 PB - GIT-Verl. CY - Darmstadt AN - OPUS4-20523 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Hampel, U. A1 - Schütze, A. A1 - Rädle, M. A1 - Rück, T. A1 - Krawczyk-Becker, M. A1 - Musch, T. A1 - Maiwald, Michael A1 - Fröhlich, H. J. A1 - Zeck, S. T1 - Positionspapier Sensorik für die Digitalisierung chemischer Produktionsanlagen N2 - Die chemische Industrie steht derzeit, wie viele andere Industriebereiche, vor den Herausforderungen einer Digitalisierung der Produktion. Sie ist der Schlüssel für die Flexibilisierung von Prozessen und Anlagen, für die Verkürzung von Produkteinführungszeiten sowie für den Zuschnitt der Produktion auf wechselnde Nachfrage und kürzere Produktlebenszyklen. Die Messtechnik und Sensorik spielt neben der intelligenten Datenverarbeitung eine Schlüsselrolle für die Digitalisierung. Flexiblere Anlagen benötigen Sensorik zur Überwachung des Anlagenzustandes, zur Früherkennung nicht bestimmungsgemäßer Betriebszustände sowie für eine bedarfsgerechte Wartung. Da die Entwicklung neuer und verbesserter Messtechnik und Sensorik grundlegend aus verschiedenen Richtungen gedacht werden muss, haben sich Akteure aus verschiedenen Branchen zusammengetan und dieses Positionspapier erstellt. Es basiert auf einer grundlegenden Analyse des Ist-Stands sowie des Bedarfs der Industrie, die unter anderem auf einem eigens dafür durchgeführten Workshop mit Sensorentwicklern, Anlagenherstellern sowie Anlagenbetreibern am 18. Juni 2019 bei der DECHEMA in Frankfurt a. M. diskutiert wurden. Diese Aktivitäten wurden maßgeblich von der Initiative Wanted Technologies der ProcessNet sowie dem AMA Verband für Sensorik und Messtechnik e.V. initiiert. KW - Prozessindustrie KW - Smarte Sensoren KW - Prozessanalytik KW - DECHEMA KW - Positionspapier PY - 2020 UR - https://dechema.de/Sensorik SP - 1 EP - 20 PB - DECHEMA CY - Frankfurt am Main AN - OPUS4-50403 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Guthausen, G. A1 - Dalitz, F. A1 - Zientek, Nicolai A1 - Nirschl, H. A1 - Kraume, M. A1 - Maiwald, Michael T1 - Applikationen der Medium-Resolution-NMR-Spektroskopie in der Prozessanalytik: Potenzial und Herausforderungen KW - Medium-Resolution-NMR-Spektroskopie KW - Prozessanalytik PY - 2012 SN - 0009-286X SN - 1522-2640 VL - 84 IS - 8 SP - 1364 PB - Wiley-VCH Verl. CY - Weinheim AN - OPUS4-28269 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Guhl, Svetlana A1 - Meyer, Klas A1 - Kern, Simon A1 - Gräßer, Patrick A1 - Maiwald, Michael ED - Maiwald, Michael T1 - Process monitoring of an intensified continuous production unit with compact NMR spectroscopy N2 - Monitoring chemical reactions is the key to chemical process control. Today, mainly optical online methods are applied. NMR spectroscopy has a high potential for direct loop process control. Compact NMR instruments based on permanent magnets are robust and relatively inexpensive analyzers, which feature advantages like low cost, low maintenance, ease of use, and cryogen-free operation. Instruments for online NMR measurements equipped with a flow-through cell, possessing a good signal-to-noise-ratio, sufficient robustness, and meeting the requirements for integration into industrial plants (i.e., explosion safety and fully automated data analysis) are cur-rently not available off the rack. Recently, promising benchtop NMR instruments with acceptable performance came to market and process integrated sensors developed on basis of such laboratory instruments are on their way. T2 - 12. Kolloquium des Arbeitskreises Prozessanalytik CY - Berlin, Germany DA - 28.11.2016 KW - Online NMR spectroscopy KW - Modular production units KW - Low field NMR spectroscopy PY - 2016 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-383646 SP - P17, 75 EP - 77 AN - OPUS4-38364 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Guhl, Svetlana A1 - Maiwald, Michael A1 - Kern, Simon A1 - Meyer, Klas A1 - Wander, Lukas A1 - Bornemann-Pfeiffer, Martin T1 - Produzieren Sie schon oder kalibrieren Sie noch? – Online-NMR-Spektrometer als Smarte Feldgeräte N2 - Der Übergang von der aktuellen Automatisierungslandschaft zur nächsten Generation von Automatisierungskonzepten für die Prozessindustrie hat bereits begonnen. Intelligente Funktionen der Sensoren vereinfachen ihre Anwendung und ermöglichen eine Plug-and-Play-Integration, auch wenn sie auf den ersten Blick komplexer erscheinen mögen. Dies ist die Basis für die Digitalisierung der Prozessindustrie und hilft uns, komplexere Prozesse schneller umzusetzen. Der Vortrag fasst die derzeit diskutierten allgemeinen Anforderungen an „Smarte Feldgeräte“ zusammen und diskutiert dieses am Beispiel eines smarten Online-NMR-Sensors. NMR-Spektroskopie bietet sich durch den Vorteil der direkten Vergleichsmethode (ohne Kalibrierung) für die Prozess-Steuerung an und verringert somit die Rüstzeiten. Zudem basiert der Sensor auf physikalisch motivierten Modellen (Indirect Hard Modeling, IHM), die sich modular kombinieren lassen. Die Methoden wurden anhand eines vorgegebenen pharmazeutischen Reaktionsschrittes im Rahmen des „Horizon 2020“-Projekts CONSENS der Europäischen Union demonstriert und validiert. Zuletzt werden Anforderungen an die Weiterentwicklung der Datenauswertemethoden diskutiert, um letztlich die semantische Information aus den Messdaten herauszulesen oder das in der Industrie 4.0 geforderte „durchgehende Engineering“ für die Automatisierungskomponenten zu ermöglichen. T2 - ProcessNet-Jahrestagung und 33. DECHEMA-Jahrestagung der Biotechnologen CY - Aachen, Germany DA - 10.09.2018 KW - Prozessindustrie KW - Prozessanalytik KW - Online-NMR-Spektroskopie KW - Datenkonzepte KW - Datenanalyse KW - CONSENS PY - 2018 N1 - Geburtsname von Bornemann-Pfeiffer, Martin: Bornemann, M. - Birth name of Bornemann-Pfeiffer, Martin: Bornemann, M. AN - OPUS4-45934 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Guhl, Svetlana A1 - Kern, Simon A1 - Meyer, Klas A1 - Wander, Lukas A1 - Bornemann-Pfeiffer, Martin A1 - Maiwald, Michael T1 - Produzieren Sie schon oder kalibrieren Sie noch? – Online-NMR-Spektrometer als Smarte Feldgeräte N2 - Der Vortrag zeigt allgemeine Anforderungen an "smarte Feldgeräte" und deren Entwicklung in den vergangenen Jahren. Am Beispiel eines smarten Online-NMR-Sensors, der in einem EU-Projekt von der BAM entwickelt wurde, wird die Umsetzung der Anforderung aufgezeigt. Schließlich werden weitere Technologieanforderungen und Lösungsansätze vorgestellt. T2 - ProcessNet-Jahrestagung und 33. DECHEMA-Jahrestagung der Biotechnologen CY - Aachen, Germany DA - 10.09.2018 KW - Prozessanalytik KW - Prozessindustrie KW - Online-NMR-Spektroskopie KW - Datenkonzepte KW - Datenanalyse KW - CONSENS PY - 2018 UR - https://onlinelibrary.wiley.com/doi/abs/10.1002/cite.201855229 DO - https://doi.org/10.1002/cite.201855229 SN - 0009-286X N1 - Geburtsname von Bornemann-Pfeiffer, Martin: Bornemann, M. - Birth name of Bornemann-Pfeiffer, Martin: Bornemann, M. VL - 90 IS - 9 SP - 1236 EP - 1236 PB - Wiley-VCH Verlag GmbH & Co. KGaA CY - Weinheim AN - OPUS4-45901 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Guhl, Svetlana A1 - Kern, Simon A1 - Meyer, Klas A1 - Gräßer, Patrick A1 - Wander, Lukas A1 - Maiwald, Michael T1 - Online NMR Spectroscopy for Process Monitoring in Intensified Continuous Production Plants N2 - Process analytical techniques are extremely useful tools for chemical production and manufacture and are of particular interest to the pharmaceutical, food and (petro-) chemical industries. Today, mainly optical online methods are applied. NMR spectroscopy has a high potential for direct loop process control. Compact NMR instruments based on permanent magnets are robust and relatively inexpensive analysers, which feature advantages like low cost, low maintenance, ease of use, and cryogen-free operation. Instruments for online NMR measurements equipped with a flow-through cell, possessing a good signal-to-noise-ratio, sufficient robustness, and meeting the requirements for integration into industrial plants (i.e., explosion safety and fully automated data analysis) are currently not available off the rack. A major advantage of NMR spectroscopy is that the method features a high linearity between absolute signal area and sample concentration, which makes it an absolute analytical comparison method which is independent of the matrix. This is an important prerequisite for robust data evaluation strategies within a control concept and reduces the need for extensive maintenance of the evaluation model over the time of operation. Additionally, NMR spectroscopy provides orthogonal, but complimentary physical information to conventional, e.g., optical spectroscopy. It increases the accessible information for technical processes, where aromatic-toaliphatic conversions or isomerizations occur and conventional methods fail due to only minor changes in functional groups. As a technically relevant example, the catalytic hydrogenation of 2-butyne-1,4-diol and further pharmaceutical reactions were studied using an online NMR sensor based on a commercially available low-field NMR spectrometer within the framework of the EU project CONSENS (Integrated Control and Sensing). T2 - 4th European Conference on Process Analytics and Control Technology (EuroPACT 2017) CY - Potsdam, Germany DA - 10.05.2017 KW - Process Monitoring KW - CONSENS KW - Online NMR Spectroscopy KW - Process Analytical Technology KW - Process control KW - Hydration KW - EuroPACT PY - 2017 SP - 103 EP - 103 CY - Frankfurt a. M. AN - OPUS4-40231 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gugin, Nikita A1 - Villajos Collado, José Antonio A1 - Dautain, O. A1 - Maiwald, Michael A1 - Emmerling, Franziska T1 - Optimizing the Green Synthesis of ZIF-8 by Reactive Extrusion Using In Situ Raman Spectroscopy N2 - We report the scale-up of a batch solid synthesis of zeolitic imidazolate framework-8 (ZIF-8) for reactive extrusion. The crystalline product forms in the extruder directly under the mixture of solid 2-methylimidazole and basic zinc carbonate in the presence of a catalytic amount of liquid. The process parameters such as temperature, liquid type, feeding rate, and linker excess were optimized using the setup specifically designed for in situ Raman spectroscopy. Highly crystalline ZIF-8 with a Brunauer–Emmett–Teller (BET) surface area of 1816 m2 g–1 was quantitatively prepared at mild temperature using a catalytic amount of ethanol and a small excess of the linker. Finally, we developed a simple and comprehensive approach to evaluating the environmental friendliness and scalability of metal–organic framework (MOF) syntheses in view of their large-scale production. KW - Mechanochemistry KW - In situ Raman KW - Large-scale processing KW - Metal−organic frameworks KW - Twin-screw extrusion (TSE) PY - 2023 DO - https://doi.org/10.1021/acssuschemeng.2c07509 SN - 2168-0485 VL - 11 IS - 13 SP - 5175 EP - 5183 PB - ACS Publications AN - OPUS4-57366 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gottu Mukkula, A. R. A1 - Kern, Simon A1 - Salge, M. A1 - Holtkamp, M. A1 - Guhl, Svetlana A1 - Fleischer, C. A1 - Meyer, Klas A1 - Remelhe, M. A1 - Maiwald, Michael A1 - Engell, S. T1 - An Application of Modifier Adaptation with Quadratic Approximation on a Pilot Scale Plant in Industrial Environment N2 - The goal of this work is to identify the optimal operating input for a lithiation reaction that is performed in a highly innovative pilot scale continuous flow chemical plant in an industrial environment, taking into account the process and safety constraints. The main challenge is to identify the optimum operation in the absence of information about the reaction mechanism and the reaction kinetics. We employ an iterative real-time optimization scheme called modifier adaptation with quadratic approximation (MAWQA) to identify the plant optimum in the presence of plant-model mismatch and measurement noise. A novel NMR PAT-sensor is used to measure the concentration of the reactants and of the product at the reactor outlet. The experiment results demonstrate the capabilities of the iterative optimization using the MAWQA algorithm in driving a complex real plant to an economically optimal operating point in the presence of plant-model mismatch and of process and measurement uncertainties. KW - Process Analytical Technology KW - Online NMR Spectroscopy KW - Process Industry KW - Iterative real-time optimization KW - Modifier adaptation KW - Plant-model mismatch KW - Reactor control KW - CONSENS PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-524531 DO - https://doi.org/10.1016/j.ifacol.2020.12.685 SN - 1522-2640 VL - 53 IS - 2 SP - 11773 EP - 11779 PB - Elsevier CY - Amsterdam AN - OPUS4-52453 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gottu Mukkula, A. R. A1 - Engell, S. A1 - Kern, Simon A1 - Guhl, Svetlana A1 - Meyer, Klas A1 - Maiwald, Michael T1 - PAT-basierte iterative Optimierung der Fahrweise eines kontinuierlichen organischen Syntheseprozesses N2 - Im Zuge der Digitalisierung der Prozessindustrie werden zunehmend modellbasiere Echtzeitoptimierungsverfahren eingesetzt, sog. „Advanced Process Control“. Mithilfe der sogenannten Modifier-Adaptation ist eine iterative Betriebspunktoptimierung auch mit ungenauen Modellen möglich, sofern zuverlässige Prozessdaten zur Verfügung stehen. Am Beispiel eines smarten Online-NMR-Sensors, der in einem EU-Projekt von der BAM entwickelt wurde, konnte das Konzept in einer modularen Produktionsanlage zur Herstellung eines pharmazeutischen Wirkstoffs erfolgreich getestet werden. T2 - ProcessNet-Jahrestagung und 33. DECHEMA-Jahrestagung der Biotechnologen CY - Aachen, Germany DA - 10.09.2018 KW - Prozessanalytik KW - Echtzeitoptimierungsverfahren KW - Modifier-Adaptation KW - Prozess-Steuerung KW - Betriebspunktoptimierung KW - CONSENS PY - 2018 UR - https://onlinelibrary.wiley.com/doi/abs/10.1002/cite.201855233 DO - https://doi.org/10.1002/cite.201855233 SN - 0009-286X VL - 90 SP - 1237 EP - 1237 PB - Wiley-VCH Verlag GmbH & Co. KGaA CY - Weinheim AN - OPUS4-45902 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Fricke, F. A1 - Mahmood, S. A1 - Hoffmann, J. A1 - Brandalero, M. A1 - Liehr, Sascha A1 - Kern, Simon A1 - Meyer, Klas A1 - Kowarik, Stefan A1 - Westerdicky, S. A1 - Maiwald, Michael A1 - Hübner, M. T1 - Artificial Intelligence for Mass Spectrometry and Nuclear Magnetic Resonance Spectroscopy N2 - Mass Spectrometry (MS) and Nuclear Magnetic Resonance Spectroscopy (NMR) are critical components of every industrial chemical process as they provide information on the concentrations of individual compounds and by-products. These processes are carried out manually and by a specialist, which takes a substantial amount of time and prevents their utilization for real-time closed-loop process control. This paper presents recent advances from two projects that use Artificial Neural Networks (ANNs) to address the challenges of automation and performance-efficient realizations of MS and NMR. In the first part, a complete toolchain has been developed to develop simulated spectra and train ANNs to identify compounds in MS. In the second part, a limited number of experimental NMR spectra have been augmented by simulated spectra to train an ANN with better prediction performance and speed than state-of-theart analysis. These results suggest that, in the context of the digital transformation of the process industry, we are now on the threshold of a possible strongly simplified use of MS and MRS and the accompanying data evaluation by machine-supported procedures, and can utilize both methods much wider for reaction and process monitoring or quality control. T2 - 2021 Design, Automation & Test in Europe Conference & Exhibition (DATE) CY - Online meeting DA - 01.02.2021 KW - Industry 4.0 KW - Cyber-Physical Systems KW - Artificial Neural Networks KW - Mass Spectrometry KW - Nuclear Magnetic Resonance Spectroscopy PY - 2021 UR - www.date-conference.com SN - 978-3-9819263-5-4 SP - 615 EP - 620 PB - Research Publishing AN - OPUS4-52180 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Fricke, F. A1 - Mahmood, S. A1 - Hoffmann, J. A1 - Brandalero, M. A1 - Liehr, Sascha A1 - Kern, Simon A1 - Meyer, Klas A1 - Kowarik, S. A1 - Westerdick, S. A1 - Maiwald, Michael A1 - Hübner, M. T1 - Artificial Intelligence for Mass Spectrometry and Nuclear Magnetic Resonance Spectroscopy N2 - Mass Spectrometry (MS) and Nuclear Magnetic Resonance Spectroscopy (NMR) are critical components of every industrial chemical process as they provide information on the concentrations of individual compounds and by-products. These processes are carried out manually and by a specialist, which takes a substantial amount of time and prevents their utilization for real-time closed-loop process control. This paper presents recent advances from two projects that use Artificial Neural Networks (ANNs) to address the challenges of automation and performance-efficient realizations of MS and NMR. In the first part, a complete toolchain has been developed to develop simulated spectra and train ANNs to identify compounds in MS. In the second part, a limited number of experimental NMR spectra have been augmented by simulated spectra to train an ANN with better prediction performance and speed than state-of-theart analysis. These results suggest that, in the context of the digital transformation of the process industry, we are now on the threshold of a possible strongly simplified use of MS and MRS and the accompanying data evaluation by machine-supported procedures, and can utilize both methods much wider for reaction and process monitoring or quality control. T2 - 2021 Design, Automation & Test in Europe Conference & Exhibition (DATE) CY - Grenoble, France DA - 01.02.2021 KW - Industry 4.0, KW - Cyber-physical systems KW - Artificial neural networks KW - Mass spectrometry KW - Nuclear magnetic resonance spectroscopy PY - 2021 DO - https://doi.org/10.23919/DATE51398.2021.9473958 SP - 615 EP - 620 PB - IEEE AN - OPUS4-55360 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Fricke, F. A1 - Brandalero, M. A1 - Liehr, Sascha A1 - Kern, Simon A1 - Meyer, Klas A1 - Kowarik, Stefan A1 - Hierzegger, R. A1 - Westerdick, S. A1 - Maiwald, Michael A1 - Hübner, M. T1 - Artificial Intelligence for Mass Spectrometry and Nuclear Magnetic Resonance Spectroscopy Using a Novel Data Augmentation Method N2 - Mass Spectrometry (MS) and Nuclear Magnetic Resonance Spectroscopy (NMR) are valuable analytical and quality control methods for most industrial chemical processes as they provide information on the concentrations of individual compounds and by-products. These processes are traditionally carried out manually and by a specialist, which takes a substantial amount of time and prevents their utilization for real-time closed-loop process control. This paper presents recent advances from two projects that use Artificial Neural Networks (ANNs) to address the challenges of automation and performance-efficient realizations of MS and NMR. In the first part, a complete toolchain has been realized to develop simulated spectra and train ANNs to identify compounds in MS. In the second part, a limited number of experimental NMR spectra have been augmented by simulated spectra, to train an ANN with better prediction performance and speed than state-of-the-art analysis. These results suggest that, in the context of the digital transformation of the process industry, we are now on the threshold of a strongly simplified use of MS and MRS and the accompanying data evaluation by machine-supported procedures, and can utilize both methods much wider for reaction and process monitoring or quality control. KW - Industry 4.0 KW - Cyber-Physical Systems KW - Artificial Neural Networks KW - Mass Spectrometry KW - Nuclear Magnetic Resonance Spectroscopy KW - Modular Production PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-539412 UR - https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=9638378 DO - https://doi.org/10.1109/TETC.2021.3131371 SN - 2168-6750 VL - 10 IS - 1 SP - 87 EP - 98 PB - IEEE AN - OPUS4-53941 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Esche, E. A1 - Müller, D. A1 - Maiwald, Michael A1 - Wozny, G. T1 - Raman-based advanced control of an absorption desorption system N2 - For absorption processes with fluctuating feed gas compositions it is vital to continuously adjust the operation point to achieve energy efficiency. In this contribution a Raman-based advanced process control (APC) is introduced for the absorption of carbon dioxide (CO2) using an aqueous solution of monoethanolamine (MEA). The APC is based on a Raman spectroscopic analysis of the composition and CO2 load of the scrubbing liquid and a non-linear model predictive control (NMPC) to adjust the scrubbing liquid cycle. In addition, an outer real-time optimization loop is set in place to update the set points for the absorption process depending on the current feed gas composition minimizing the energy consumption of the process. Implementation and testing of the APC have been carried out in a mini-plant at TU Berlin. During a plant operation of more than 160 hours robustness and stability of the APC were shown. T2 - 12th International Symposium on Process Systems Engineering and 25th European Symposium on Computer Aided Process Engineering CY - Kopenhagen, Denmark DA - 31.05.2015 KW - Raman spectroscopy KW - Advanced process control KW - CO2 KW - Carbon dioxide KW - Absorption KW - Process analytical technology PY - 2015 UR - https://www.elsevier.com/books/12th-international-symposium-on-process-systems-engineering-and-25th-european-symposium-on-computer-aided-process-engineering/author/978-0-444-63429-0 SN - 9780444634290 SN - 9780444634450 VL - 37 SP - 1523 EP - 1528 PB - Elsevier CY - Amsterdam AN - OPUS4-37669 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Esche, E. A1 - Kraemer, B. A1 - Müller, D. A1 - Meyer, Klas A1 - Zientek, Nicolai A1 - Maiwald, Michael A1 - Wozny, G. T1 - Improved desorption control via Raman spectroscopy N2 - In this contribution a Raman spectrometer based control structure for the heating of a desorption column is proposed. For this purpose calibration experiments for the absorption of carbon dioxide using monoethanolamine solutions are carried out and calibration models are developed to measure both carbon dioxide liquid loads and monoethanolamine mass fractions. The calibration experiments are supported by online NMR spectroscopy to accurately measure the appearance of all species in the electrolyte system. Both models are tested during the plant operation of a mini-plant for the oxidative coupling of methane and the proof of concept for the control structure is given. The Raman spectroscopy implemented in the ATEX conform mini-plant shows a reliable and robust performance being even indifferent to impurities hindering the GC analysis. T2 - 20th International Conference of Process Engineering and Chemical Plant Design CY - Berlin, Germany DA - 15.10.2014 KW - Absorption KW - Carbon capture KW - Raman spectroscopy KW - desorption control KW - Prozessanalytik KW - Process analytical technology PY - 2014 UR - https://www.verfahrenstechnik.tu-berlin.de/fileadmin/fg158/Dokumente/Manuskripte/2014/20th-ICPEPD-Proceedings.pdf SN - 978-3-00-047364-7 SP - 223 EP - 233 PB - Technische Universität Berlin CY - Berlin AN - OPUS4-37399 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Eisen, K A1 - Eifert, T A1 - Herwig, C A1 - Maiwald, Michael T1 - Current and future requirements to industrial analytical infrastructure—part 1: process analytical laboratories N2 - The competitiveness of the chemical and pharmaceutical industry is based on ensuring the required product quality while making optimum use of plants, raw materials, and energy. In this context, effective process control using reliable chemical process analytics secures global competitiveness. The setup of those control strategies often originate in process development but need to be transferable along the whole product life cycle. In this series of two contributions, we want to present a combined view on the future of PAT (process analytical technology), which is projected in smart labs (part 1) and smart sensors (part 2). In laboratories and pilot plants, offline chemical analytical methods are frequently used, where inline methods are also used in production. Here, a transferability from process development to the process in operation would be desirable. This can be obtained by establishing PAT methods for production already during process development or scale-up. However, the current PAT (Bakeev 2005, Org Process Res 19:3–62; Simon et al. 2015, Org Process Res Dev 19:3–62) must become more flexible and smarter. This can be achieved by introducing digitalization-based knowledge management, so that knowledge from product development enables and accelerates the integration of PAT. Conversely, knowledge from the production process will also contribute to product and process development. This contribution describes the future role of the laboratory and develops requirements therefrom. In part 2, we examine the future functionality as well as the ingredients of a smart sensor aiming to eventually fuel full PAT functionality—also within process development or scale-up facilities (Eifert et al. 2020, Anal Bioanal Chem). KW - Smart test laboratories KW - Laboratory 4.0 KW - Sustainable Production KW - Industry 4.0 PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-504020 DO - https://doi.org/10.1007/s00216-020-02420-2 SN - 1618-2642 VL - 412 IS - 9 SP - 2027 EP - 2035 PB - Springer CY - Berlin Heidelberg AN - OPUS4-50402 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Eifert, T. A1 - Eisen, K. A1 - Maiwald, Michael A1 - Herwig, C. T1 - Current and future requirements to industrial analytical infrastructure—part 2: smart sensors N2 - Complex processes meet and need Industry 4.0 capabilities. Shorter product cycles, flexible production needs, and direct assessment of product quality attributes and raw material attributes call for an increased need of new process analytical technologies (PAT) concepts. While individual PAT tools may be available since decades, we need holistic concepts to fulfill above industrial needs. In this series of two contributions, we want to present a combined view on the future of PAT (process analytical technology), which is projected in smart labs (Part 1) and smart sensors (Part 2). Part 2 of this feature article series describes the future functionality as well as the ingredients of a smart sensor aiming to eventually fuel full PAT functionality. The smart sensor consists of (i) chemical and process information in the physical twin by smart field devices, by measuring multiple components, and is fully connected in the IIoT 4.0 environment. In addition, (ii) it includes process intelligence in the digital twin, as to being able to generate knowledge from multi-sensor and multi-dimensional data. The cyber-physical system (CPS) combines both elements mentioned above and allows the smart sensor to be self-calibrating and self-optimizing. It maintains its operation autonomously. Furthermore, it allows—as central PAT enabler—a flexible but also target-oriented predictive control strategy and efficient process development and can compensate variations of the process and raw material attributes. Future cyber-physical production systems—like smart sensors—consist of the fusion of two main pillars, the physical and the digital twins. We discuss the individual elements of both pillars, such as connectivity, and chemical analytics on the one hand as well as hybrid models and knowledge workflows on the other. Finally, we discuss its integration needs in a CPS in order to allow is versatile deployment in efficient process development and advanced optimum predictive process control. KW - Smart sensors KW - Industry 4.0 KW - Digital twins KW - Process intelligence KW - Process analytical technology KW - Physical twin KW - Cyber-physical system PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-503980 DO - https://doi.org/10.1007/s00216-020-02421-1 SN - 1618-2642 VL - 412 IS - 9 SP - 2037 EP - 2045 PB - Springer CY - Berlin Heidelberg AN - OPUS4-50398 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dalitz, F. A1 - Maiwald, Michael A1 - Guthausen, G. T1 - Considerations on the design of flow cells in by-pass systems for process analytical applications and its influence on the flow profile using NMR and CFD N2 - The design of sample flow cells, commonly used in on-line analytics and especially for medium resolution NMR spectroscopy (MR-NMR) in low magnetic fields, was experimentally and theoretically investigated by 1H NMR and numerical simulations. The flow pattern was characterised to gain information about the residence time distribution and mixing effects. Both 1H NMR imaging and spectroscopy were used to determine the characteristics of flow cells and their significance for on-line measurements such as reaction monitoring or hyphenated separation spectroscopy. The volume flow rates investigated were in the range from 0.1 to 10 ml/min, typically applied in the above mentioned applications. The special characteristics of flow cells for MR-NMR were revealed by various NMR experiments and compared with CFD simulations and to flow cells commonly used in high-field NMR. The influence of the design of the inlet and outlet on the flow pattern was investigated as well as the effect of the length of the cell. For practical use, a numerical estimation of the inflow length was given. In addition, it was shown how experiments on the polarisation build-up revealed insight into the flow characteristics in MR-NMR. KW - Chemical processes KW - Imaging KW - Instrumentation KW - Process control KW - NMR KW - CFD PY - 2012 DO - https://doi.org/10.1016/j.ces.2012.03.042 SN - 0009-2509 VL - 75 SP - 318 EP - 326 PB - Elsevier CY - Amsterdam AN - OPUS4-25792 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Daliltz, F. A1 - Cudaj, M. A1 - Maiwald, Michael A1 - Guthausen, G. T1 - Process and reaction monitoring by low-field NMR spectroscopy KW - Process analysis KW - Low-field NMR spectroscopy KW - Flow-NMR KW - Data analysis PY - 2012 DO - https://doi.org/10.1016/j.pnmrs.2011.11.003 SN - 0079-6565 SN - 1873-3301 VL - 60 SP - 52 EP - 70 PB - Elsevier CY - Amsterdam AN - OPUS4-25439 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Carl, Peter A1 - Paul, Andrea A1 - Maiwald, Michael T1 - Spektroskopische Untersuchungen an Bioprozess- Simulationsproben N2 - Zur Onlineüberwachung von Fermentationsprozessen werden zunehmend schwingungsspektroskopische (Raman-, Mittel- und Nahinfrarotspektroskopie (NIRS) und UV-/VIS- Methoden(Absorptions- und Fluoreszenzspektroskopie) in Kombination mit multivariater Auswertung eingesetzt. Anliegen dieser Arbeit war es, zu testen, welche Verfahren für die spektroskopische On- und Offlineüberwachung des Fermentationsprozesses zur biotechnologischen Herstellung einer Malariavaccine grundlegend geeignet sind und welche Messbereiche und Genauigkeiten der Vorhersage im Idealfall bei der Abwesenheit von Hefezellen erzielt werden können. T2 - 10. Kolloquium Arbeitskreis Prozessanalytik CY - Gerlingen, Germany DA - 25.11.2014 KW - Prozessanalytik KW - Prozess-Sensoren KW - Bioprozess KW - Prozess-Spektroskopie KW - Raman-Spektroskopie KW - Nahinfrarot-Spektroskopie KW - Fluoreszenz-Spektroskopie PY - 2014 UR - http://arbeitskreis-prozessanalytik.de/images/stories/Veranstaltungen/Kolloquien/10_kolloquium_2014/tagungsband_10_kolloquium_ak_prozessanalytik_2014_hq-druck_f.pdf SP - P13, 35 EP - 35 PB - BAM Bundesanstalt für Materialforschung und -prüfung CY - Berlin AN - OPUS4-38362 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Böttinger, W. A1 - Maiwald, Michael A1 - Hasse, H. ED - Renon, H. T1 - Online NMR spectroscopic study of species distribution in MEA-H2O-CO2 and DEA-H2O-CO2 KW - Amine KW - MEA KW - DEA KW - NMR KW - Speciation PY - 2008 DO - https://doi.org/10.1016/j.fluid.2007.09.017 SN - 0378-3812 VL - 263 IS - 2 SP - 131 EP - 143 PB - Elsevier CY - Amsterdam AN - OPUS4-19359 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Böttinger, W. A1 - Maiwald, Michael A1 - Hasse, H. T1 - Online NMR spectroscopic study of species distribution in MDEA-H2O-CO2 and MDEA-PIP-H2O-CO2 PY - 2008 DO - https://doi.org/10.1021/ie800914m SN - 0888-5885 SN - 1520-5045 VL - 47 IS - 20 SP - 7917 EP - 7926 PB - American Chemical Society CY - Washington, DC AN - OPUS4-19360 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bröcker, S. A1 - Klaer, R.-H. A1 - Kockmann, N. A1 - Maiwald, Michael T1 - Process Industry United in the Digital World - The current landscape of research for the digitalization of the process industry N2 - The Tutzing Symposium "100 % digital: survival strategies for the process industry" (see 4.1) in April 2018 was characterized by a great momentum which has been taken up and continued until today. The aim was to implement the ideas from the Tutzing Symposium in a coordinated and targeted manner. For this purpose, development needs as well as the numerous currently planned or already started research and development activities in the context of digitalisation were first compiled and analysed. This resulted in the current research landscape for digitalization in the process industry. It now enables to identify open topics and to translate them into research funding programs as well as to define new projects in the dialogue between users, suppliers and research, which are to be meaningfully interlinked and consolidated with existing projects. Due to the strong interest in digitalisation, activities are constantly being added, so that this paper can only provide a snapshot of the situation in the period 2019-2020. KW - Process Industry KW - Digitalisation KW - Tutzing Symposion KW - research landscape KW - Process Control PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-512265 UR - https://processnet.org/en/TAKdigital.html SP - 1 EP - 15 AN - OPUS4-51226 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bremser, Wolfram A1 - Paul, Andrea A1 - Neugebauer, Michael A1 - Maiwald, Michael A1 - Brudel, M. T1 - Immer im Bild mittels Prozess-Spektroskopie - Spektroskopische Methoden für die Prozessanalytik PY - 2012 SN - 0016-3538 VL - 56 IS - 6 SP - 436 EP - 439 PB - GIT-Verlag CY - Darmstadt AN - OPUS4-26243 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bremser, Wolfram A1 - Maiwald, Michael A1 - Kipphardt, Heinrich T1 - Anwendung von Normen in der Gasanalytik - Teil 4 - Messunsicherheit und Rückführbarkeit von Messergebnissen N2 - Zusammen mit der Genauigkeit von Messungen ist die ihnen zugeordnete Messunsicherheit Ausdruck und Maß von Vergleichbarkeit und Richtigkeit. Die Messunsicherheit spielt ebenso die Schlüsselrolle im Aufbau einer Rückführbarkeitskette, wie in diesem Beitrag beschrieben. Es ist der vierte und letzte Teil einer Artikelserie (siehe Infokasten), die Einblicke gibt in die Arbeit des DIN-Normenausschusses „Gasanalyse und Gasbeschaffenheit“ (DIN NA 062-05-73 AA) sowie der international tätigen Technical Committees 158 und 193 der ISO. KW - Normen KW - Messunsicherheit KW - Rückführbarkeit PY - 2015 SN - 1436-2597 SN - 1439-0663 IS - 12 SP - 29 EP - 31 PB - GIT-Verl., Wiley-VCH CY - Weinheim AN - OPUS4-35258 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bornemann-Pfeiffer, Martin A1 - Meyer, Klas A1 - Lademann, J. A1 - Kraume, M. A1 - Maiwald, Michael T1 - Contributions towards variable temperature shielding for compact NMR instruments N2 - The application of compact NMR instruments to hot flowing samples or exothermically reacting mixtures is limited by the temperature sensitivity of permanent magnets. Typically, such temperature effects directly influence the achievable magnetic field homogeneity and hence measurement quality. The internal-temperature control loop of the magnet and instruments is not designed for such temperature compensation. Passive insulation is restricted by the small dimensions within the magnet borehole. Here, we present a design approach for active heat shielding with the aim of variable temperature control of NMR samples for benchtop NMR instruments using a compressed airstream which is variable in flow and temperature. Based on the system identification and surface temperature measurements through thermography, a model predictive control was set up to minimise any disturbance effect on the permanent magnet from the probe or sample temperature. This methodology will facilitate the application of variable-temperature shielding and, therefore, extend the application of compact NMR instruments to flowing sample temperatures that differ from the magnet temperature. KW - Benchtop NMR KW - Continuous Processes KW - Inline Analytics KW - Model Predictive Control KW - Process Analytical Tecnology KW - Temperature Control PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-579219 DO - https://doi.org/10.1002/mrc.5379 SN - 1097-458X SP - 1 EP - 10 PB - John Wiley & Sons Ltd. AN - OPUS4-57921 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bornemann-Pfeiffer, Martin A1 - Kern, Simon A1 - Maiwald, Michael A1 - Meyer, Klas T1 - Calibration-Free Chemical Process and Quality Control Units as Enablers for Modular Production N2 - Modular chemical production is a tangible translation of the digital transformation of the process industry for specialty chemicals. In particular, it enables the speeding-up of process development and thus a quicker time to market by flexibly connecting and orchestrating standardised physical modules and bringing them to life (i.e., parameterising them) with digitally accumulated process knowledge. We focus on the specific challenges of chemical process and quality control, which in its current form is not well suited for modular production and provide possible approaches and examples of the change towards direct analytical methods, analytical model transfer or machine-supported processes. KW - Modular Production KW - Chemical Process Control KW - Process Analytical Technology KW - Digital Transformation KW - Industry 4.0 PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-517264 DO - https://doi.org/10.1002/cite.202000150 SN - 1522-2640 VL - 93 IS - 1-2 SP - 62 EP - 70 PB - Wiley-VCH CY - Weinheim AN - OPUS4-51726 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bornemann-Pfeiffer, Martin A1 - Kern, Simon A1 - Jurtz, N. A1 - Thiede, Tobias A1 - Kraume, M. A1 - Maiwald, Michael T1 - Design and validation of an additively manufactured flowCell–static mixer combination for inline NMR spectroscopy N2 - There have been an increasing number of publications on flow chemistry applications of compact NMR. Despite this, there is so far no comprehensive workflow for the technical design of flow cells. Here, we present an approach that is suitable for the design of an NMR flow cell with an integrated static mixing unit. This design moves the mixing of reactants to the active NMR detection region within the NMR instrument, presenting a feature that analyses chemical reactions faster (5–120 s region) than other common setups. During the design phase, the targeted mixing homogeneity of the components was evaluated for different types of mixing units based on CFD simulation. Subsequently, the flow cell was additively manufactured from ceramic material and metal tubing. Within the targeted working mass flow range, excellent mixing properties as well as narrow line widths were confirmed in validation experiments, comparable to common glass tubes. KW - Inline NMR Spectroscopy KW - Integrated Processes KW - Reaction Monitoring KW - Process Analytical Technology KW - Flow Chemistry KW - Static Mixing KW - Modular Production PY - 2019 UR - https://pubs.acs.org/doi/abs/10.1021/acs.iecr.9b03746 DO - https://doi.org/10.1021/acs.iecr.9b03746 SN - 0888-5885 SN - 1520-5045 N1 - Geburtsname von Bornemann-Pfeiffer, Martin: Bornemann, M. - Birth name of Bornemann-Pfeiffer, Martin: Bornemann, M. VL - 58 IS - 42 SP - 19562 EP - 19570 PB - American Chemical Society CY - Washington AN - OPUS4-49041 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Blazek, M. A1 - Deilmann, M. A1 - Gasch, A. A1 - Gerlach, M. A1 - Grümbel, F. A1 - Kaiser, U. A1 - Kloska, M. A1 - Löbbecke, S. A1 - Maiwald, Michael A1 - Pötter, T. A1 - Rebner, K. A1 - Roos, E. A1 - Stieler, S. A1 - Stolz, D. A1 - Theuer, M. A1 - Berthold, J. A1 - Engelhard, H. T1 - Technologie-Roadmap "Prozesssensoren 4.0" N2 - Mit den Technologie-Roadmaps „Prozesssensoren 2005–2015“ [1] (2006) und „Prozesssensoren 2015+“ [2] und [3] (2009) wurden Grundlagen für alle Unternehmen der Prozessindustrie geschaffen, um zielgerichtet auf Kundenbedürfnisse der Prozessindustrie zugeschnittene Produktentwicklungen, technologische Weiterentwicklungen und Forschungsprojekte zum Erfolg zu bringen. Die Roadmap „Prozesssensoren 2015+“ fand große Akzeptanz aufgrund der soliden Betrachtung der Prozesse und der daraus abgeleiteten Thesen. Diese Aussagen haben in vollem Umfang weiterhin Gültigkeit. Im Rückblick auf die damals formulierten Entwicklungsziele wurden viele dieser Ziele im prognostizierten Zeithorizont auf den Weg gebracht und teilweise bereits umgesetzt. In dieser Technologie-Roadmap werden einige Beispiele dazu aufgezeigt. KW - Roadmap KW - Industrie 4.0 KW - Prozess-Sensoren KW - Prozessanalytik KW - Sensoren PY - 2015 UR - http://www.namur.net/fileadmin/media_www/Roadmap_Dateien/Roadmap_Prozesssensoren_4.0.pdf SP - 1 EP - 36 AN - OPUS4-34947 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Bernstein, Michael A1 - Diehl, Bernd W. K. A1 - Holzgrabe, Ulrike A1 - Maiwald, Michael A1 - Meyer, Klas A1 - Monakhova, Yulia A1 - Schönberger, Torsten T1 - qNMR - The handbook N2 - Quantitative NMR (qNMR) has been around for a long time, but also has great potential to solve future problems in any quantitative analysis. As a primary method, it differs fundamentally from chromatographic methods: it is better described as a quantum mechanical balance. Succesful implementation of qNMR requires certain attention to detail. "qNMR - the handbook" is intended to be a guide for analysts to help understand the fundamental principles of NMR and the significant points relating to its implementation for quantitation. Regulatory considerations of qNMR adoption are explained. NMR fundamentals are explained to provide understanding. Together with many useful examples, the book is a compelling addition to the laboratory's reference library, providing all the tools that any practitioner should know to successfully implement qNMR. The authors are qNMR pioneers and come from a variety of backgrounds including business, government and academia. KW - Quantitative NMR spectroscopy KW - NMR spectroscopy KW - Handbook KW - qNMR PY - 2023 SN - 978-3-7568-7891-8 SN - 978-3-7583-8050-1 SP - 1 EP - 302 PB - BoD – Books on Demand CY - Norderstedt AN - OPUS4-59839 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Batzdorf, Lisa A1 - Zientek, Nicolai A1 - Rump, Doreen A1 - Fischer, Franziska A1 - Maiwald, Michael A1 - Emmerling, Franziska T1 - Make and break - Facile synthesis of cocrystals and comprehensive dissolution studies N2 - Mechanochemistry is increasingly used as a ‘green alternative’ for synthesizing various materials including pharmaceutical cocrystals. Herein, we present the mechanochemical synthesis of three new cocrystals containing the API carbamazepine (cocrystals CBZ:Indometacin 1:1, CBZ:Benzamide 1:1, and CBZ:Nifedipine 1:1). The mechanochemical reaction was investigated in situ documenting a fast and complete reaction within one minute. Online NMR spectroscopy proved the direct influence of the dissolution behaviour of the coformers to the dissolution behaviour of the API carbamazepine. The dissolution behaviour of the organic cocrystals is compared to the behaviour of the pure drug indicating a general applicability of this approach for detailed cocrystal dissolution studies. KW - Cocrystals KW - Carbamazepine KW - Mechanochemistry KW - Powder diffraction KW - Online NMR spectroscopy PY - 2017 DO - https://doi.org/10.1016/j.molstruc.2016.11.063 SN - 0022-2860 SN - 1872-8014 VL - 1133 SP - 18 EP - 23 AN - OPUS4-38664 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Balderas-Xicohtencatl, R. A1 - Villajos Collado, José Antonio A1 - Casabán, J. A1 - Wong, D. A1 - Maiwald, Michael A1 - Hirscher, M. T1 - ZIF‑8 Pellets as a Robust Material for Hydrogen Cryo-Adsorption Tanks N2 - Cryoadsorption on the inner surface of porous materials is a promising solution for safe, fast, and reversible hydrogen storage. Within the class of highly porous metal−organic frameworks, zeolitic imidazolate frameworks (ZIFs) show high thermal, chemical, and mechanical stability. In this study, we selected ZIF-8 synthesized mechanochemically by twin-screw extrusion as powder and pellets. The hydrogen storage capacity at 77 K and up to 100 bar has been analyzed in two laboratories applying three different measurement setups showing a high reproducibility. Pelletizing ZIF-8 increases the packing density close to the corresponding value for a single crystal without loss of porosity, resulting in an improved volumetric hydrogen storage capacity close to the upper limit for a single crystal. The high volumetric uptake combined with a low and constant heat of adsorption provides ca. 31 g of usable hydrogen per liter of pellet assuming a temperature−pressure swing adsorption process between 77 K − 100 bar and 117 K − 5 bar. Cycling experiments do not indicate any degradation in storage capacity. The excellent stability during preparation, handling, and operation of ZIF-8 pellets demonstrates its potential as a robust adsorbent material for technical application in pilot- and full-scale adsorption vessel prototypes. KW - Hydrogen adsorption storage KW - Metal−organic frameworks KW - ZIF-8 KW - Cryoadsorption KW - Hydrogen Storage KW - MefHySto PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-569473 DO - https://doi.org/10.1021/acsaem.2c03719 SN - 2574-0962 SP - 1 EP - 8 PB - ACS Publications CY - Washington DC AN - OPUS4-56947 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Alfeld, M. A1 - Eckhardt, H.-S. A1 - Kraft, J. A1 - Maiwald, Michael A1 - Meermann, Björn A1 - Merz, K. A1 - Prikler, S. A1 - Richert, J. A1 - Steiner, G. A1 - von Tümpling, W. T1 - Trendbericht Analytische Chemie N2 - Zusätzlich zu Methodenentwicklung, Miniaturisierung und Kopplungsverfahren zeigen sich die Hyperspektroskopie zusammen mit Imaging‐Verfahren, der Einzelmolekülnachweis und der Einsatz von 3‐D‐Druckern als neue Schwerpunkte. Hinzu kommen künstliche Intelligenz bei Sensoren, Bildgebungsverfahren und Prozesssteuerung sowie die Vernetzung von Analyse‐ und Laborgeräten. Trends und Forschungsthemen aus der analytischen Chemie, zusammengestellt von elf Autoren, koordiniert von Günter Gauglitz. KW - Multielementanalytik KW - Multimodale Analytik KW - Kristallolgraphie KW - Prozessanalytik KW - Prozessindustrie KW - Industrielle Analytik KW - Chemometrik KW - Chemometrie PY - 2020 DO - https://doi.org/10.1002/nadc.20204095786 SN - 1868-0054 VL - 68 IS - 4 SP - 52 EP - 60 PB - Wiley CY - Weinheim AN - OPUS4-50609 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -