TY - JOUR A1 - Walter, Astrid A1 - Panne, Ulrich A1 - Weller, Michael G. T1 - A novel immunoreagent for the specific and sensitive detection of the explosive triacetone triperoxide (TATP) N2 - Triacetone triperoxide (TATP) is a primary explosive, which was used in various terrorist attacks in the past. For the development of biosensors, immunochemical µ-TAS, electronic noses, immunological test kits, or test strips, the availability of antibodies of high quality is crucial. Recently, we presented the successful immunization of mice, based on the design, synthesis, and conjugation of a novel TATP derivative. Here, the long-term immunization of rabbits is shown, which resulted in antibodies of extreme selectivity and more than 1,000 times better affinity in relation to the antibodies from mice. Detection limits below 10 ng L-1 (water) were achieved. The working range covers more than four decades, calculated from a precision profile. The cross-reactivity tests revealed an extraordinary selectivity of the antibodies—not a single compound could be identified as a relevant cross-reactant. The presented immunoreagent might be a major step for the development of highly sensitive and selective TATP detectors particularly for security applications. KW - Organic peroxides KW - Terrorism KW - Biosensor development PY - 2011 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-240291 UR - http://www.mdpi.com/2079-6374/1/3/93 DO - https://doi.org/10.3390/bios1030093 SN - 2079-6374 VL - 1 IS - 3 SP - 93 EP - 106 PB - MDPI CY - Basel AN - OPUS4-24029 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - INPR A1 - Tchipilov, Teodor A1 - Meyer, Klas A1 - Weller, Michael G. T1 - Quantitative 1H nuclear magnetic resonance (qNMR) of aromatic amino acids for protein quantification N2 - qNMR is a valuable technique for metrological studies due to the uniformity of its signal response for all chemical species of an isotope of interest, which enables compound-independent calibration. However, protein quantification remained challenging as large molecules produce wide, low-intensity signals that reduce the already low sensitivity. Combining qNMR with the hydrolysis of protein samples into amino acids circumvents many of these issues and facilitates the use of NMR spectroscopy for absolute protein and peptide quantification.In this work, different conditions have been tested for quantifying aromatic amino acids and proteins. First, we examined the pH-based signal shifts in the aromatic region. The preferable pH depends on the selection of the amino acids for quantification and which internal standard substance should be used to avoid peak overlap. Several aromatic compounds, such as terephthalic acid, sulfoisophthalic acid, and benzene tricarboxylic acid, have been applied as internal standards. The quantification of amino acids from an amino acid standard, as well as from a certified reference material (bovine serum albumin), was performed. Using the first two suggested internal standards, recovery was ~ 97 % for histidine, phenylalanine, and tyrosine at a concentration of approximately 1 mM in solution. Acidic hydrolysis of a certified reference material (CRM) of bovine serum albumin (BSA) and subsequent quantification of Phe and Tyr yielded recoveries of 98 ± 2 and 88 ± 4 %, respectively, at a protein concentration of 16 g/L or 250 µM. KW - Amino acid analysis KW - AAA KW - Protein hydrolysis KW - Metrology KW - Traceability KW - Reference materials KW - Internal standards KW - Calibration PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-564520 DO - https://doi.org/10.20944/preprints202211.0569.v1 SP - 1 EP - 13 PB - MDPI CY - Basel AN - OPUS4-56452 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Cervino, C. A1 - Knopp, D. A1 - Weller, Michael G. A1 - Niessner, R. T1 - Novel Aflatoxin derivatives and protein conjugates N2 - Aflatoxins, a group of structurally related mycotoxins, are well known for their toxic and carcinogenic effects in humans and animals. Aflatoxin derivatives and protein conjugates are needed for diverse analytical applications. This work describes a reliable and fast synthesis of novel aflatoxin derivatives, purification by preparative HPLC and characterisation by ESI-MS and one- and two-dimensional NMR. Novel aflatoxin bovine serum albumin conjugates were prepared and characterised by UV absorption and MALDI-MS. These aflatoxin protein conjugates are potentially interesting as immunogens for the generation of aflatoxin selective antibodies with novel specificities. KW - Aflatoxin KW - Mycotoxin KW - Hapten KW - Protein conjugation KW - Immunogen KW - Antigen KW - Antibody PY - 2007 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-147572 UR - http://www.mdpi.org/molecules/papers/12030641.pdf UR - http://www.mdpi.org/molecules/papers/12030641sm.pdf DO - https://doi.org/10.3390/12030641 SN - 1420-3049 VL - 12 IS - 3 SP - 641 EP - 653 PB - MDPI CY - Basel AN - OPUS4-14757 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Klykov, Oleg A1 - Weller, Michael G. T1 - Quantification of N-hydroxysuccinimide and N-hydroxysulfosuccinimide by hydrophilic interaction chromatography (HILIC) N2 - N-Hydroxysuccinimide (NHS) esters are the most important activated esters used in many different bioconjugation techniques, such as protein labelling by fluorescent dyes and enzymes, surface activation of chromatographic supports, microbeads, nanoparticles, and microarray slides, and also in the chemical synthesis of peptides. Usually, reactions with NHS esters are very reliable and of high yield, however, the compounds are sensitive to air moisture and water traces in solvents. Therefore, the quantification of NHS would be a very helpful approach to identify reagent impurities or degradation of stored NHS esters. No robust and sensitive method for the detection of NHS (or the more hydrophilic sulfo-NHS) has been reported yet. Here, a chromatographic method based on HILIC conditions and UV detection is presented, reaching a detection limit of about 1 mg L-1, which should be sensitive enough for most of the applications mentioned above. Exemplarily, the hydrolytic degradation of a biotin-NHS ester and a purity check of a fluorescent dye NHS ester are shown. An important advantage of this approach is its universality, since not the structurally variable ester compound is monitored, but the constant degradation product NHS or sulfo-NHS, which avoids the necessity to optimize the separation conditions and facilitates calibration considerably. KW - NHS KW - Sulfo-NHS KW - NHS-Ester KW - Qualitätskontrolle KW - Reinheitsbestimmung KW - HPLC PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-337833 DO - https://doi.org/10.1039/c5ay00042d SN - 1759-9660 SN - 1759-9679 VL - 7 IS - 15 SP - 6443 EP - 6448 PB - RSC Publ. CY - Cambridge AN - OPUS4-33783 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Weller, Michael G. T1 - Antibody-based SAW sensor for the detection of explosives N2 - A robust and sensitive method for the detection of the explosive trinitrotoluene (TNT) was developed. The detection limit was determined to be around 0.5 µg/L. The fast signal response of less than 1 minute shows that this approach is suitable for security and other time-critcal applications. In addition, the very low cross-reactivity highly reduces the number of false-positives in relation to competing techniques, including sniffer dogs. Due to the multianalyte ability of the SAW system, several explosives might be detected in parallel. T2 - BAM Meeting 2016 CY - Berlin, Germany DA - 17.02.2016 KW - TNT KW - Trinitrotoluene KW - Explosives KW - Airport security KW - High-speed biosensor KW - Selectivity KW - Sensitivity KW - Self-assembled monolayer KW - Gold surface KW - Immunosensor KW - Reversibility KW - Inhibition assay KW - Polyethylene glycol KW - PEG PY - 2016 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-366265 UR - http://f1000research.com/posters/5-1352 DO - https://doi.org/10.7490/f1000research.1112309.1 AN - OPUS4-36626 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Weller, Michael G. T1 - Identification of toxicants in complex environmental samples using HPLC combined online with toxicity testing T2 - Anakon 2007 CY - Jena, Germany DA - 2007-03-27 PY - 2007 AN - OPUS4-14737 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Giesen, Charlotte A1 - Jakubowski, Norbert A1 - Panne, Ulrich A1 - Weller, Michael G. T1 - Comparison of ICP-MS and photometric detection of an immunoassay for the determination of ochratoxin A in wine N2 - An immunoassay was developed for ochratoxin A (OTA) detection in wine and two completely different detection methods were compared: ICP-MS and photometry. For labelling, we applied secondary antibodies conjugated with gold nanoparticles for ICP-MS and with horseradish peroxidase for photometric detection, respectively. Detection limits of the assay were determined as 0.003 µg L-1 for both detection methods. OTA in wine was determined below the EU limit value of 2 µg kg-1. The measurement range was between 0.01 and 1 µg L-1 for ICP-MS and photometric detection. Assay precision detected by ICP-MS and photometry were similar showing that precision of the detection method has only a minor effect on total assay precision. By using BSA as a buffer additive to minimize nonspecific binding, we could also confirm that OTA strongly binds to BSA. In a comparison study of several additives, casein was found to be preferable. PY - 2010 DO - https://doi.org/10.1039/c0ja00009d SN - 0267-9477 SN - 1364-5544 VL - 25 IS - 10 SP - 1567 EP - 1572 PB - Royal Society of Chemistry CY - London AN - OPUS4-22704 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Pecher, Heike Susanne A1 - Zimathies, Annett A1 - Weller, Michael G. T1 - Oligoepoxide-based monoliths: synthesis and application as affinity capillary column for enrichment of immunoglobulin G N2 - A series of new epoxide-based monoliths is synthesized by self-polymerization of polyglycerol polyglycidyl ether as porous support for affinity chromatography. Porosity and mean pore sizes are investigated as a function of the porogen ratio and analyzed by mercury porosimetry. The morphologies are visualized by environmental scanning electron microscope. With a particularly rigid monolith prepared with 75 vol% porogen (66% porosity and 12 µm mean pore size), a capillary column (0.5 mm ID) is prepared and directly functionalized with recombinant protein A to extract immunoglobulin G from rabbit serum. KW - Affinity chromatography KW - Affinity extraction KW - Glycidylethers KW - Macroporous polymers KW - Polyethers PY - 2012 DO - https://doi.org/10.1002/macp.201200206 SN - 1022-1352 SN - 1521-3935 VL - 213 IS - 22 SP - 2398 EP - 2403 PB - Wiley-VCH Verl. CY - Weinheim AN - OPUS4-27390 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Carvalho, José Joao A1 - Weller, Michael G. A1 - Panne, Ulrich A1 - Schneider, Rudolf T1 - Monitoring caffeine in human saliva using a newly developed ELISA N2 - Caffeine is a useful indicator to quickly assess liver function. High-throughput tests are needed for single-point caffeine measurements, with low cross-reactivity toward its major metabolite, paraxanthine. A newly developed ELISA was compared with an LC-MS/MS reference method, using 60 saliva samples from 10 individuals, before and after caffeine intake. Bland-Altman plot, Student t-test and F-test were used to compare the two methods. Proteins were precipitated using organic solvent and the caffeine recoveries compared with those obtained using sample microfiltration. The antibody, with a low cross-reactivity toward paraxanthine (0.08%), allows quantification of caffeine in saliva samples from 2.5 µg/L to 125 µg/L with high precision and the ELISA shows comparable results to those obtained by LC-MS/MS. A one-step protein precipitation using an organic solvent provides comparable results to a more costly and time-consuming microfiltration pre-treatment of samples. The new ELISA is a fit-for-purpose method to accurately and precisely determine caffeine in saliva samples. KW - Caffeine KW - Cytochrome P450 CYP1A2 KW - Enzyme-linked immunosorbent assay KW - LC-MS/MS KW - Liver function tests KW - Saliva PY - 2012 DO - https://doi.org/10.1080/00032719.2012.696226 SN - 0003-2719 SN - 1532-236X VL - 45 IS - 17 SP - 2549 EP - 2561 PB - Taylor & Francis CY - Philadelphia, Pa. AN - OPUS4-27267 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bahlmann, Arnold A1 - Weller, Michael G. A1 - Panne, Ulrich A1 - Schneider, Rudolf T1 - Monitoring carbamazepine in surface and wastewaters by an immunoassay based on a monoclonal antibody N2 - The pharmaceutical compound carbamazepine (CBZ) is an emerging pollutant in the aquatic environment and may potentially be used as a wastewater marker. In this work, an enzyme-linked immunosorbent assay (ELISA) for the detection of carbamazepine in surface and sewage waters has been developed. The heterogeneous immunoassay is based on a commercially available monoclonal antibody and a novel enzyme conjugate (tracer) that links the hapten via a hydrophilic peptide (triglycine) spacer to horseradish peroxidase. The assay achieves a limit of detection of 24 ng/L and a quantitation range of 0.05-50 µg/L. The analytical performance and figure of merits were compared to liquid chromatography-tandem mass spectrometry after solid-phase extraction. For nine Berlin surface water samples and one wastewater sample, a close correlation of results was observed. A constant overestimation relative to the CBZ concentration of approximately 30% by ELISA is probably caused by the presence of 10,11-epoxy-CBZ and 2-hydroxy-CBZ in the samples. The ELISA displayed cross-reactivities for these compounds of 83% and 14%, respectively. In a first screening of 27 surface water samples, CBZ was detected in every sample with concentrations between 0.05 and 3.2 µg/L. Since no sample cleanup is required, the assay allowed for the determination of carbamazepine with high sensitivity at low costs and with much higher throughput than with conventional methods. KW - Carbamazepine KW - ELISA KW - Antibody KW - Immunoassay KW - Surface water KW - LC-MS/MS KW - Pharmaceuticals PY - 2009 DO - https://doi.org/10.1007/s00216-009-2958-7 SN - 1618-2642 SN - 1618-2650 VL - 395 IS - 6 SP - 1809 EP - 1820 PB - Springer CY - Berlin AN - OPUS4-20927 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Weller, Michael G. T1 - Das Phantom von Heilbronn - Eine Herausforderung für die Analytik? KW - Wattestäbchen KW - DNA KW - Spurensicherung KW - Qualitätskontrolle KW - Analytische Expertise PY - 2009 SN - 0939-0065 IS - 3 SP - 11 EP - 12 PB - Gesellschaft Deutscher Chemiker CY - Frankfurt, M. AN - OPUS4-19890 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Carvalho, José Joao A1 - Walter, Astrid A1 - Baermann, Yvonne A1 - Weller, Michael G. A1 - Panne, Ulrich A1 - Schenk, J.A. A1 - Schneider, Rudolf T1 - Non-invasive monitoring of immunization progress in mice via IgG from feces N2 - A non-invasive method to monitor the humoral immune response in mice after immunization is described. From fecal pellets of an individual mouse, a sufficient amount of active immunoglobulins or their fragments can be extracted to perform a regular examination of the status of the immune response by immunoassay. Hapten-specific antibodies from the feces of mice from three immunization trials showed very similar characteristics to those obtained from serum at a given date. Therefore, it can be suspected that some serum IgG enters the intestinal lumen and ends up in the feces, where they appear to be considerably stable. Hapten-specific IgAs were not found in the feces. Being able to analyze antibody titers in feces could be an interesting animal welfare refinement to standard practice that does not entail repeated blood sampling. KW - Immunization monitoring KW - IgG KW - Coproantibodies KW - Feces KW - Animal welfare KW - 3R concept PY - 2012 UR - http://iv.iiarjournals.org/content/26/1/63.full.pdf+html SN - 0258-851x VL - 26 IS - 1 SP - 63 EP - 70 PB - In vivo CY - Athens AN - OPUS4-25283 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Weller, Michael G. T1 - Detection of explosives by bioanalytical techniques T2 - Potsdam Days on Bioanalysis 2011 CY - Potsdam, Germany DA - 2011-11-09 PY - 2011 AN - OPUS4-24952 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Stolper, P. A1 - Fabel, S. A1 - Weller, Michael G. A1 - Knopp, D. A1 - Niessner, R. T1 - Whole-cell luminescence-based flow-through biodetector for toxicity testing N2 - A new type of biodetector was designed based on a bioluminescence test with the bacterium Vibrio fischeri performed in a liquid continuous flow-through system. Here we describe the modification of a commercial tube luminescence detector to work in the flow mode by building a new flow cell holder and a new case including “top cover” to connect the flow cell with the waste and the incubation capillary in a light-proof manner. As different samples were injected successively it was necessary to keep the individual peaks separated. This was done using an air-segmented flow in the reaction coil. To afford fast screening, the incubation time of the sample and the Vibrio fischeri, which equaled the dead time of the detection system, was set at 5.6 min. Rapid monitoring of toxic substances is achieved by using 20 µL of sample and flow-rates of 110–150 µL min-1. As a proof-of-principle, we show results for the detection of five selected di-, tri- and tetrachlorophenols at different concentrations varying from 1 to 200 mg L-1. Calculation of inhibition rates and EC50 values were performed and compared with corresponding values from the DIN EN ISO 11348-2 microplate format. Compared with the latter, the inhibition rates obtained with our flow-through biodetector for the compounds tested were generally about twofold lower, but importantly, a much faster detection is possible. KW - Biosensor KW - Air-segmented flow KW - Vibrio fischeri KW - Bioluminescence KW - Toxicity test PY - 2008 DO - https://doi.org/10.1007/s00216-007-1770-5 SN - 1618-2642 SN - 1618-2650 VL - 390 IS - 4 SP - 1181 EP - 1187 PB - Springer CY - Berlin AN - OPUS4-17713 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Descalzo López, Ana Belén A1 - Xu, H.-J. A1 - Xue, Z.-L. A1 - Hoffmann, Katrin A1 - Shen, Z. A1 - Weller, Michael G. A1 - You, X.-Z. A1 - Rurack, Knut T1 - Phenanthrene-Fused Boron-Dipyrromethenes as Bright Long-Wavelength Fluorophores N2 - A new class of boron-dipyrromethene (BDP or BODIPY) dyes was obtained by phenanthrene fusion to the β-pyrrole positions, absorbing in the wavelength range of important laser sources. Despite a 'propeller-like' distorted structure in the crystalline state, the chromophore absorbs (log ε ≥ 5) and fluoresces (Φf ≥ 0.8) strongly and can be easily turned into a fluorescence light-up probe. Incorporation into latex beads produces bright and photostable single-dye and Förster Resonance Energy Transfer (FRET) particles for microscopy applications. KW - Fluoreszenz KW - Absorption KW - BODIPY-Farbstoffe KW - Ladungstransfer KW - NIR-Farbstoffe PY - 2008 DO - https://doi.org/10.1021/ol800271e SN - 1523-7060 SN - 1523-7052 VL - 10 IS - 8 SP - 1581 EP - 1584 PB - American Chemical Society CY - Washington, DC AN - OPUS4-17511 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Baumgartner, S. A1 - Fürtler-Leitzenberger, I. A1 - Drs, E. A1 - Molinelli, A. A1 - Krska, R. A1 - Immer, U. A1 - Schmitt, K. A1 - Bremer, M. A1 - Haasnoot, W. A1 - Danks, C. A1 - Romkies, V. A1 - Reece, P. A1 - Wilson, P. A1 - Kiening, M. A1 - Weller, Michael G. A1 - Niessner, R. A1 - Corsini, E. A1 - Mendonca, S. ED - Darsa P. Siantar, ED - Mary W. Trucksess, ED - Peter M. Scott, ED - Eliot M. Herman, T1 - European survey for hidden allergens in food: A case study with peanut and hazelnut KW - Allergene KW - Erdnuß KW - Haselnuß KW - Allergentest KW - Lebensmittel KW - Kontamination PY - 2008 SN - 978-0-8412-6954-5 N1 - Serientitel: ACS Symposium Series – Series title: ACS Symposium Series SP - 370 EP - 381 AN - OPUS4-19052 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Weller, Michael G. T1 - Schnelle analytische Techniken für Screening und Monitoring KW - Immunsensoren KW - Immunoassays KW - Teststreifen KW - Probenahme PY - 2008 SN - 0939-0065 IS - 2 SP - 24 PB - Gesellschaft Deutscher Chemiker CY - Frankfurt, M. AN - OPUS4-17599 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Walter, Astrid A1 - Pfeifer, Dietmar A1 - Kraus, Werner A1 - Emmerling, Franziska A1 - Schneider, Rudolf A1 - Panne, Ulrich A1 - Weller, Michael G. T1 - Triacetone Triperoxide (TATP): Hapten design and development of antibodies N2 - Triacetone triperoxide (TATP), an improvised explosive, is a potential security threat because of its cost-efficient synthesis and the difficulty in detecting it. A highly selective antibody could provide the necessary specificity to the detection process. To obtain antibodies, a hapten made from acetone, hydrogen peroxide, and 7-oxooctanoic acid has been designed, synthesized, and confirmed by NMR that displays the utmost similarity to the analyte. The single-crystal X-ray structures of the solvated species TATP·methanol (1:1) and the TATP derivate were determined. In both compounds, the molecules exhibit D3 symmetry and adopt a twisted boat-chair conformation. The hapten was coupled to bovine serum albumin, and mice were immunized. An immune response against TATP was elicited, and selective antibodies were detected in the mouse serum, which should be very useful for the development of a TATP biosensor system. An ELISA with a limit of detection for TATP of 65 µg L-1 is shown. KW - TATP KW - Triacetone triperoxide KW - Explosive KW - Antibody KW - Hapten immunoassay KW - Structure PY - 2010 DO - https://doi.org/10.1021/la1018339 SN - 0743-7463 SN - 1520-5827 VL - 26 IS - 19 SP - 15418 EP - 15423 PB - American Chemical Society CY - Washington, DC AN - OPUS4-22469 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Carvalho, José Joao A1 - Weller, Michael G. A1 - Panne, Ulrich A1 - Schneider, Rudolf T1 - A highly sensitive caffeine immunoassay based on a monoclonal antibody KW - Caffeine KW - ELISA KW - Antibody KW - LC–MS–MS KW - Water KW - Wastewater marker PY - 2010 DO - https://doi.org/10.1007/s00216-010-3506-1 SN - 1618-2642 SN - 1618-2650 VL - 396 IS - 7 SP - 2617 EP - 2628 PB - Springer CY - Berlin AN - OPUS4-22651 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Giesen, Charlotte A1 - Jakubowski, Norbert A1 - Panne, Ulrich A1 - Weller, Michael G. T1 - Ochratoxin-A-Bestimmung in Wein mittels eines ICP-MS-basierten Immunoassays PY - 2010 UR - http://www.analytik-news.de/Fachartikel/Volltext/BAM2.pdf SP - 1 EP - 6 PB - Dr. Beyer Internet-Beratung CY - Ober-Ramstadt AN - OPUS4-22702 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ramin, Steffen A1 - Weller, Michael G. T1 - Extremely sensitive and selective antibodies against the explosive 2,4,6-trinitrotoluene by rational design of a structurally optimized hapten N2 - Antibodies are a promising tool for the fast and selective trace detection of explosives. Unfortunately, the production of high-quality antibodies is not trivial and often expensive. Therefore, excellent antibodies are a rare and limiting resource in fields such as biosensing, environmental analysis, diagnostics, cancer therapy, and proteomics. Here, we report the synthesis, bioconjugation, and application of the structurally optimized hapten 6-(2,4,6-trinitro)-phenylhexanoic acid to improve the selectivity and sensitivity of antibodies for the detection of one of the most important explosives, trinitrotoluene. With a conjugate of bovine serum albumin and a highly purified N-hydroxy-succinimide (NHS)–activated hapten, two rabbits were immunized to obtain polyclonal antibodies. The immunization process was monitored by enzyme-linked immunosorbent assay to gain information about the progress of antibody titer and affinity. Finally, the polyclonal antibodies reached an affinity constant of (5.1 ± 0.6) × 109l/mol (rabbit R1) and (2.3 ± 0.2) × 109l/mol (rabbit R2). The respective assays show a minimum test midpoint (IC50 value) of 0.1 ± 0.01 µg/l (R1) and 0.2 ± 0.02 µg/l (R2) and a working range of 0.005 to 150 µg/l (R1) and 0.007 to 200 µg/l (R2), which corresponds to more than four orders of magnitude for both. This is quite remarkable for a competitive immunoassay, which is often believed to have a narrow dynamic range. The limit of detection was calculated to 0.6 ng/l (R1) and 1.5 ng/l (R2), which is up to 100 times improvement in relation to the assay of Zeck et al. (1999) on the basis of a monoclonal antibody. The excellent selectivity of the polyclonal antibodies was comprehensively examined by determining the cross-reactivity to common explosives and other nitroaromatics including nitro musk components. The widely held belief that polyclonal antibodies generally display higher cross-reactivities than monoclonals could be disproved. KW - Immunoassay KW - ELISA KW - Security KW - Terrorism PY - 2012 DO - https://doi.org/10.1002/jmr.2162 SN - 0952-3499 SN - 1099-1352 VL - 25 IS - 2 SP - 89 EP - 97 PB - Heyden CY - London AN - OPUS4-25441 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Steglich, Patrick A1 - Paul, Martin A1 - Mai, C. A1 - Böhme, A. A1 - Bondarenko, S. A1 - Weller, Michael G. A1 - Mai, A. T1 - A monolithically integrated microfluidic channel in a silicon-based photonic-integrated-circuit technology for biochemical sensing N2 - In this work, a cost-effective optofluidic system is proposed and preliminary experimental results are presented. A microfluidic channel monolithically integrated into a photonic integrated circuit technology is used in conjunction with a cyclic olefin copolymer (COC) substrate to provide fluidic in- and output ports. We report on initial experimental results as well as on the simple and cost-effective fabrication of this optofluidic system by means of micro-milling. KW - Biosensors KW - Biophotonics KW - Optical sensors KW - Photonic sensors KW - Ring resonators KW - Silicon photonics KW - Lab-on-a-chip KW - Microfluidics KW - Chip KW - Biochip PY - 2021 DO - https://doi.org/10.1117/12.2588791 VL - 11772 SP - 1 EP - 5 PB - SPIE AN - OPUS4-53559 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Weller, Michael G. T1 - One-bead-one-peptide libraries, their application, and other topics N2 - A novel method for screening one-bead-one-peptide libraries is presented and discussed. The approach comprises the following steps: 1. The peptide library is synthesized on peptide beads with a 4-(hydroxymethyl)benzoic acid (HMBA) linker. 2. The beads are placed on glass slides equipped with electrically conductive double-sided adhesive tape using a precision sieve. 3. The chip is incubated with fluorescence-labeled target molecules (e.g., antibodies or receptors) and scanned with a fluorescence scanner to identify the positive beads. 4. The peptides are cleaved from the polymer beads using ammonia gas. 5. The MALDI matrix is applied using a spray gun. 6. The positive beads are sequenced using MALDI-ToF-MS. T2 - Berlin-Delhi Network Symposium CY - Berlin, Germany DA - 31.10.2025 KW - Peptide KW - Aptamer KW - Bibliothek PY - 2025 AN - OPUS4-64562 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Climent Terol, Estela A1 - Gröninger, Delia A1 - Hecht, Mandy A1 - Walter, Astrid A1 - Martínez-Mánez, Ramon A1 - Weller, Michael G. A1 - Sancenón, F. A1 - Amorós, P. A1 - Rurack, Knut T1 - Selective, sensitive, and rapid analysis with lateral-flow assays based on antibody-gated dye-delivery systems: The example of triacetone triperoxide N2 - Set them free: Brightly fluorescent indicators that are loaded into mesoporous silica nanoparticle carriers, capped with bulky antibodies, are released into the lateral flow of a test strip upon analyte arrival. Integration of the system into a rapid, simple flow test with fluorescence readout is applied for the selective and sensitive determination of the presence of triacetone triperoxide (TATP) as a prototype small-molecule analyte (see figure). KW - Farbstoffe KW - Sprengstoffe KW - Fluoreszenz KW - Immunoassays KW - Mesoporöse Materialien PY - 2013 DO - https://doi.org/10.1002/chem.201300031 SN - 0947-6539 SN - 1521-3765 VL - 19 IS - 13 SP - 4117 EP - 4122 PB - Wiley-VCH Verl. CY - Weinheim AN - OPUS4-29508 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Steglich, P. A1 - Mai, C. A1 - Bondarenko, S. A1 - Paul, Martin A1 - Weller, Michael G. A1 - Schrader, S. A1 - Mai, A. T1 - BioPIC - Integration of Biosensors based on Photonic Integrated Circuits by Local-Backside Etching N2 - Silicon photonic sensors are promising candidates for lab-on-a-chip solutions with versatile applications and scalable production prospects using complementary metal-oxide semiconductor (CMOS) fabrication methods. However, the widespread use has been hindered because the sensing area adjoins optical and electrical components making packaging and sensor handling challenging. In this work, a local back-side release of the photonic sensor is employed, enabling a separation of the sensing area from the rest of the chip. This approach allows preserving the compatibility of photonic integrated circuits in the front-end of line and metal interconnects in the back-end of line. T2 - ATTRACT online Conference CY - Online meeting DA - 22.09.2020 KW - Silicon Photonics KW - Photonic Sensor KW - Photonic Integrated Circuits KW - Point-Of-Care-Diagnostics KW - CMOS KW - Microfluidics KW - Lab-on-a-chip KW - Ring resonator PY - 2020 UR - https://attract-eu.com/showroom/project/integration-of-biosensors-based-on-photonic-integrated-circuits-by-local-backside-etching-biopic/ SP - 1 EP - 5 AN - OPUS4-51735 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Weller, Michael G. T1 - Methods for immunoaffinity extraction – Setup and characterization N2 - Affinity extraction is one of the most powerful separation methods. Regarded to be indispensable in some research fields, such as proteomics, the application in other fields is still scarce or even waning. Many researchers fear the perceived complexity, cost and unreliability of this approach. The presentation gives a broad overview of the most important methods and discusses some important points for their implementation. Having considered these aspects, it should be easier to establish an affinity separation approach to resolve challenging analytical questions. T2 - Seminar des Max-Planck-Instituts für Chemie (MPIC) CY - Mainz, Germany DA - 28.09.2016 KW - affinity chromatography KW - immunoaffinity KW - antibodies KW - sample preparation KW - bioanalysis PY - 2016 AN - OPUS4-37736 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Krop, U. A1 - Scherz, Franziska A1 - Weller, Michael G. A1 - Monks, K. T1 - Fast and robust purification of antibodies from human serum with a new monolithic protein A column N2 - The use of antibodies is becoming more and more important. Therewith the need for fast and robust methods for their purification and columns with a long lifetime is growing. In this application, we describe a fast and robust protein A affinity chromatography method with a new monolithic column. Antibodies were successfully purified in less than 1.5 minutes with a flowrate of 5 mL/min highlighting the advantages of this column and method. KW - Antibodies KW - Protein A KW - MNPQ KW - Technology transfer KW - Human serum KW - Purification KW - IgG KW - SDS PAGE KW - Regeneration PY - 2017 UR - http://www.knauer.net/en/application/fast_and_robust_purification_of_antibodies_from_human_serum_with_a_new_monolithic_protein_a_column.html SP - 1 EP - 2 PB - Knauer CY - Berlin AN - OPUS4-43163 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Lemke, Nora A1 - El-Khatib, Ahmed H. A1 - Tchipilov, Teodor A1 - Jakubowski, N. A1 - Weller, Michael G. A1 - Vogl, Jochen T1 - Procedure providing SI‑traceable results for the calibration of protein standards by sulfur determination and its application on tau N2 - Quantitative proteomics is a growing research area and one of the most important tools in the life sciences. Well-characterized and quantified protein standards are needed to achieve accurate and reliable results. However, only a limited number of sufficiently characterized protein standards are currently available. To fill this gap, a method for traceable protein quantification using sulfur isotope dilution inductively coupled plasma mass spectrometry (ICP-MS) was developed in this study. Gel filtration and membrane filtration were tested for the separation of non-protein-bound sulfur in the protein solution. Membrane filtration demonstrated a better performance due to the lower workload and the very low sulfur blanks of 11 ng, making it well suited for high-purity proteins such as NIST SRM 927, a bovine serum albumin (BSA). The method development was accomplished with NIST SRM 927e and a commercial avidin. The quantified mass fraction of NIST SRM 927e agreed very well with the certified value and showed similar uncertainties (3.6%) as established methods while requiring less sample preparation and no species-specific standards. Finally, the developed procedure was applied to the tau protein, which is a biomarker for a group of neurodegenerative diseases denoted “tauopathies” including, e.g., Alzheimer’s disease and frontotemporal dementia. For the absolute quantification of tau in the brain of transgenic mice overexpressing human tau, a well-defined calibration standard was needed. Therefore, a pure tau solution was quantified, yielding a protein mass fraction of (0.328 ± 0.036) g/kg, which was confirmed by amino acid analysis. KW - Iinductively coupled plasma mass spectrometry KW - Isotope dilution KW - Quantitative protein analysis KW - Sulfur KW - SI traceability PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-545200 DO - https://doi.org/10.1007/s00216-022-03974-z VL - 414 SP - 4441 EP - 4455 PB - Springer Verlag AN - OPUS4-54520 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Weller, Michael G. T1 - Quality issues of research antibodies N2 - According to several recent studies, an unexpectedly high number of landmark papers seem to be not reproducible by Independent laboratories. Nontherapeutic antibodies used for research, diagnostic, food analytical, environmental, and other purposes play a significant role in this matter. Although some papers have been published offering suggestions to improve the situation, they do not seem to be comprehensive enough to cover the full complexity of this issue. In addition, no obvious improvements could be noticed in the field as yet. This article tries to consolidate the remarkable variety of conclusions and suggested activities into a more coherent conception. It is concluded that funding agencies and journal publishers need to take first and immediate measures to resolve these problems and lead the way to a more sustainable way of bioanalytical research, on which all can rely with confidence. KW - reproducibility crisis KW - irreproducibility KW - replication KW - paper retraction KW - peer reviewimmunochemistry KW - immunoassay KW - ligand binding assay KW - monoclonal antibody KW - quality control KW - cross-reactivity KW - non-specific binding KW - selectivity PY - 2016 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-356254 DO - https://doi.org/10.4137/ACI.S31614 SN - 1177-3901 VL - 11 SP - 21 EP - 27 PB - Libertas Academica CY - Auckland, New Zealand AN - OPUS4-35625 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Waiblinger, H. U. A1 - Bartsch, D. A1 - Brockmeyer, J. A1 - Bruenen-Nieweler, C. A1 - Busch, U. A1 - Haase, I. A1 - Hahn, A. A1 - Haarmann, M. A1 - Hauser, W. A1 - Huber, I. A1 - Jany, K. D. A1 - Kirmse, N. A1 - Lindeke, S. A1 - Neumann, K. A1 - Naumann, H. A1 - Paschke, A. A1 - Pietsch, K. A1 - Pöpping, B. A1 - Reiting, R. A1 - Schroeder, U. A1 - Schwägele, F. A1 - Weller, Michael G. A1 - Zagon, J. T1 - Methods of differentiating animal species in foods – Status quo N2 - Work on standardising methods in the field of animal species differentiation has been intensified in Germany in recent years, not least due to the horsemeat scandal in 2013. Even though there are now hardly ever any positive findings any more in examinations to detect horse adulterations in foods such as lasagne, animal species differentiation altogether ranks high in detecting adulteration of foods. This article therefore summarises the current status of analytical techniques used in Germany with standardisation at German level. It has been established by the working group “Biochemical and Molecular Biological Analytics” of the Lebensmittelchemische Gesellschaft (Food Chemistry Society within the German Chemical Society) with support of experts in the working group “Molecular biology techniques for differentiating plant and animal species” (§ 64 of the German Food and Feed Code – LFGB) and the “Immunology and molecular biology” task force of the food hygiene and Food of animal origin working group (ALTS), both from Germany. KW - Animal species differentiation KW - Fish species KW - PCR KW - Standardisation KW - DNA chip KW - Multiplex methods KW - Digital PCR KW - ELISA methods KW - Immunoassays KW - LC-MS/MS KW - Reference materials KW - Microarrays KW - LAMP KW - Interlaboratory studies PY - 2017 SN - 0179-2415 VL - 97 IS - 1 SP - 50 EP - 55 PB - Deutscher Fachverlag GmbH CY - Frankfurt AN - OPUS4-39264 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bierstedt, Andreas A1 - You, Yi A1 - van Wasen, Sebastian A1 - Bosc-Bierne, Gaby A1 - Weller, Michael G. A1 - Riedel, Jens T1 - Laser-Induced Microplasma as an Ambient Ionization Approach for the Mass-Spectrometric Analysis of Liquid Samples N2 - An airborne high repetition rate laser-induced plasma was applied as a versatile ambient ionization source for mass-spectrometric determinations of polar and nonpolar analytes in solution. The laser plasma was sustained between a home-built pneumatic nebulizer and the inlet capillary of an Orbitrap mass spectrometer. To maintain stable conditions in the droplet-rich spray environment, the plasma was directly fed by the fundamental output (λ = 1064 nm) of a current state-of-the-art diode-pumped solid-state laser. Ionization by the laser-driven plasma resulted in signals of intact analyte ions of several chemical categories. The analyte ions were found to be fully desolvated since no further increase in ion signal was observed upon heating of the inlet capillary. Due to the electroneutrality of the plasma, both positive and negative analyte ions could be formed simultaneously without altering the operational parameters of the ion source. While, typically, polar analytes with pronounced gas phase basicities worked best, nonpolar and amphoteric compounds were also detected. The latter were detected with lower ion signals and were prone to a certain degree of fragmentation induced during the ionization process. All the described attests the laser-induced microplasma by a good performance in terms of stability, robustness, sensitivity, and general applicability as a self-contained ion source for the liquid sample introduction. KW - Laser KW - Laser-induced plasma KW - Ambient ionization KW - Mass Spectrometry PY - 2019 DO - https://doi.org/10.1021/acs.analchem.9b00329 SN - 0003-2700 VL - 91 IS - 9 SP - 5922 EP - 5928 PB - American Chemical Society CY - Washington, DC, USA AN - OPUS4-47939 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Weller, Michael G. T1 - The mystery of homochirality on earth N2 - Homochirality is an obvious feature of life on Earth. On the other hand, extraterrestrial samples contain largely racemic compounds. The same is true for any common organic synthesis. Therefore, it has been a perplexing puzzle for decades how these racemates could have formed enantiomerically enriched fractions as a basis for the origin of homochiral life forms. Numerous hypotheses have been put forward as to how preferentially homochiral molecules could have formed and accumulated on Earth. In this article, it is shown that homochirality of the abiotic organic pool at the time of formation of the first self-replicating molecules is not necessary and not even probable. It is proposed to abandon the notion of a molecular ensemble and to focus on the level of individual molecules. Although the formation of the first self-replicating, most likely homochiral molecule, is a seemingly improbable event, on a closer look, it is almost inevitable that some homochiral molecules have formed simply on a statistical basis. In this case, the non-selective leap to homochirality would be one of the first steps in chemical evolution directly out of a racemic “ocean”. Moreover, most studies focus on the chirality of the primordial monomers with respect to an asymmetric carbon atom. However, any polymer with a minimal size that allows folding to a secondary structure would spontaneously lead to asymmetric higher structures (conformations). Most of the functions of these polymers would be influenced by this inherently asymmetric folding. Furthermore, a concept of physical compartmentalization based on rock nanopores in analogy to nanocavities of digital immunoassays is introduced to suggest that complex cell walls or membranes were also not required for the first steps of chemical evolution. To summarize, simple and universal mechanisms may have led to homochiral self-replicating systems in the context of chemical evolution. A homochiral monomer pool is deemed unnecessary and probably never existed on primordial Earth. N2 - Homochiralität ist ein offensichtliches Merkmal des Lebens auf der Erde. Andererseits enthalten extraterrestrische Proben überwiegend racemische Verbindungen. Dasselbe gilt für jede gängige organische Synthese. Daher war es jahrzehntelang ein Rätsel, wie diese Racemate enantiomeren-angereicherte Fraktionen als Grundlage für den Ursprung homochiraler Lebensformen bilden konnten. Zahlreiche Hypothesen wurden aufgestellt, wie sich bevorzugt homochirale Moleküle auf der Erde gebildet und angereichert haben könnten. In diesem Artikel wird gezeigt, dass Homochiralität des abiotischen organischen Pools zum Zeitpunkt der Bildung der ersten selbstreplizierenden Moleküle nicht notwendig und nicht einmal wahrscheinlich ist. Es wird vorgeschlagen, die Vorstellung eines molekularen Ensembles aufzugeben und sich auf die Ebene der einzelnen Moleküle zu konzentrieren. Obwohl die Bildung des ersten selbstreplizierenden, höchstwahrscheinlich homochiralen Moleküls ein scheinbar unwahrscheinliches Ereignis ist, ist es bei näherer Betrachtung fast unvermeidlich, dass sich einige homochirale Moleküle einfach auf statistischer Basis gebildet haben. In diesem Fall wäre der nichtselektive Sprung zur Homochiralität einer der ersten Schritte der chemischen Evolution direkt aus einem racemischen "Ozean". Darüber hinaus konzentrieren sich die meisten Studien auf die Chiralität der ursprünglichen Monomere in Bezug auf ein asymmetrisches Kohlenstoffatom. Jedes Polymer mit einer Mindestgröße, die eine Faltung zu einer Sekundärstruktur erlaubt, würde jedoch spontan zu asymmetrischen höheren Strukturen (Konformationen) führen. Die meisten Funktionen dieser Polymere würden durch diese inhärent asymmetrische Faltung beeinflusst. Darüber hinaus wird ein Konzept der physikalischen Kompartimentierung auf der Basis von Gesteinsnanoporen in Analogie zu den Nanokavitäten digitaler Immunoassays vorgestellt, das darauf hindeutet, dass auch für die ersten Schritte der chemischen Evolution keine komplexen Zellwände oder Membranen notwendig waren. Zusammenfassend lässt sich sagen, dass einfache und universelle Mechanismen zu homochiralen selbstreplizierenden Systemen im Rahmen der chemischen Evolution geführt haben könnten. Ein homochiraler Monomerpool wird als unnötig angesehen, welcher auf der Urerde wahrscheinlich nie existiert hat. KW - Chemical evolution KW - Enantiomeric excess ee KW - Chirality KW - Racemate KW - Folding chirality KW - Self-assembly KW - self-replication KW - Single molecule KW - Prebiotic chemistry KW - Protein folding KW - Peptide folding KW - Proteinoid KW - Conformation KW - Segregation KW - Compartmentalization KW - Digital immunoassay KW - Porous rock KW - Miller and Urey KW - Primordial soup KW - Murchison meteorite KW - Micrometeorites KW - Tholins PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-598349 DO - https://doi.org/10.3390/life14030341 SN - 2075-1729 VL - 14 IS - 3 SP - 1 EP - 13 PB - MDPI CY - Basel AN - OPUS4-59834 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - INPR A1 - Bosc-Bierne, Gaby A1 - Ewald, Shireen A1 - Kreuzer, Oliver J. A1 - Weller, Michael G. T1 - Efficient Quality Control of Peptide Pools N2 - Peptide pools composed of short amino acid sequences have proven to be versatile tools in various research areas and clinical applications. They are powerful tools for epitope mapping, immunotherapy, and vaccine development. Their importance lies in their ability to map complex protein structures, enabling a comprehensive understanding of immune responses and facilitating the identification of potential therapeutic agents. The application of peptide pools also extends to the field of personalized medicine, offering tailored solutions for diseases such as cancer and infectious diseases. Peptide pools are complex mixtures of immunostimulatory antigens primarily intended for T-cell stimulation. They are commercially available in many different compositions and variants. However, unlike other reagents that consist of only one or a few compounds, peptide pools are highly complex products with limited stability. This makes their quality control a major challenge. Quantitative peptide analysis usually requires sophisticated methods, in most cases isotope-labeled standards and reference materials. None of these are routinely available for these products. Synthesis and purification of all labeled peptides might be required. Usually, this approach would be prohibitively laborious and expensive. Therefore, an approach is needed to provide a practical and feasible method for quality control of peptide pools. With insufficient quality control, the use of such products could lead to incorrect experimental results, which would worsen the well-known reproducibility crisis in the biomedical sciences. Here we propose the use of ultra-high performance liquid chromatography (UHPLC) with two detectors, a standard UV detector (at 214 nm) for quantitative analysis and a high-resolution mass spectrometer (HRMS) for identity confirmation. To be cost-efficient and fast, quantification and identification are performed in one chromatographic run. An optimized protocol is shown, and different peak integration methods are compared and discussed. This work was performed using a peptide pool known as CEF, which consists of 32 peptides derived from cytomegalovirus (CMV), Epstein-Barr virus (EBV) and influenza virus, ranging from 8 to 12 amino acids in length. N2 - Peptidpools, die aus kurzen Aminosäuresequenzen bestehen, haben sich in verschiedenen Forschungsbereichen und klinischen Anwendungen als vielseitige Werkzeuge erwiesen. Sie sind leistungsstarke Werkzeuge für die Epitopkartierung, die Immuntherapie und die Impfstoffentwicklung. Ihre Bedeutung liegt in ihrer Fähigkeit, komplexe Proteinstrukturen zu kartieren, was ein umfassendes Verständnis der Immunantworten ermöglicht und die Identifizierung potenzieller Therapeutika erleichtert. Die Anwendung von Peptidpools erstreckt sich auch auf den Bereich der personalisierten Medizin und bietet maßgeschneiderte Lösungen für Krankheiten wie Krebs und Infektionskrankheiten. Peptidpools sind komplexe Mischungen immunstimulierender Antigene, die hauptsächlich zur T-Zell-Stimulation bestimmt sind. Sie sind in vielen verschiedenen Zusammensetzungen und Varianten im Handel erhältlich. Im Gegensatz zu anderen Reagenzien, die nur aus einer oder wenigen Verbindungen bestehen, sind Peptidpools jedoch hochkomplexe Produkte mit begrenzter Stabilität. Dies macht ihre Qualitätskontrolle zu einer großen Herausforderung. Die quantitative Peptidanalyse erfordert in der Regel ausgefeilte Methoden, in den meisten Fällen isotopenmarkierte Standards und Referenzmaterialien. Keines dieser Verfahren ist für diese Produkte routinemäßig verfügbar. Möglicherweise ist die Synthese und Reinigung aller markierten Peptide erforderlich. In der Regel wäre dieser Ansatz unerschwinglich aufwendig und teuer. Daher ist ein Ansatz erforderlich, der eine praktische und praktikable Methode für die Qualitätskontrolle von Peptidpools bietet. Bei unzureichender Qualitätskontrolle könnte die Verwendung solcher Produkte zu falschen Versuchsergebnissen führen, was die bekannte Reproduzierbarkeitskrise in den biomedizinischen Wissenschaften verschlimmern würde. Hier schlagen wir die Verwendung der Ultrahochleistungsflüssigkeitschromatographie (UHPLC) mit zwei Detektoren vor, einem Standard-UV-Detektor (bei 214 nm) für die quantitative Analyse und einem hochauflösenden Massenspektrometer (HRMS) für die Identitätsbestätigung. Um kosteneffizient und schnell zu sein, werden Quantifizierung und Identifizierung in einem chromatographischen Durchlauf durchgeführt. Es wird ein optimiertes Protokoll vorgestellt und verschiedene Peak-Integrationsmethoden werden verglichen und diskutiert. Diese Arbeit wurde mit einem Peptidpool namens CEF durchgeführt, der aus 32 Peptiden besteht, die vom Cytomegalovirus (CMV), Epstein-Barr-Virus (EBV) und Influenzavirus stammen und zwischen 8 und 12 Aminosäuren lang sind. KW - Quality control KW - UHPLC-UV-HRMS KW - Relative peptide quantification KW - Compound confirmation KW - Structure confirmation KW - Cost efficiency KW - Infectious diseases KW - Orbitrap PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-621307 DO - https://doi.org/10.20944/preprints202404.0992.v1 SN - 2310-287X SP - 1 EP - 18 PB - MDPI CY - Basel AN - OPUS4-62130 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - INPR A1 - Völzke, Jule L. A1 - Hodjat Shamami, Parya A1 - Gawlitza, Kornelia A1 - Feldmann, Ines A1 - Zimathies, Annett A1 - Weller, Michael G. T1 - High-purity corundum as support for affinity extractions from complex samples N2 - Nonporous corundum powder, known as an abrasive material in the industry, was functionalized covalently with protein binders to isolate and enrich specific proteins from complex matrices. The materials based on corundum were characterized by TEM, ESEM, BET, DLS, and zeta potential measurements. The strong Al-O-P bonds between the corundum surface and amino phosphonic acids are used to introduce functional groups for further conjugations. The common cross-linker glutaraldehyde was compared with a hyperbranched polyglycerol (PG) of around 10 kDa. The latter is oxidized with periodate to generate aldehyde groups that can covalently react with the amines of the surface and the amino groups from the protein via a reductive amination process. The amount of bound protein was quantified via aromatic amino acid analysis (AAAA). This work shows that oxidized polyglycerol can be used as an alternative to glutaraldehyde. With polyglycerol, more of the model protein bovine serum albumin (BSA) could be attached to the surface under the same conditions, and lower nonspecific binding (NSB) was observed. As a proof of concept, IgG was extracted with protein A from crude human plasma. The purity of the product was examined by SDS-PAGE. A binding capacity of 1.8 mg IgG per g of corundum powder was achieved. The advantages of corundum are the very low price, extremely high physical and chemical stability, pressure resistance, favorable binding kinetics, and flexible application. KW - Protein KW - Bioseparation KW - Purification KW - Immunoprecipitation KW - Affinity chromatography KW - Polyglycerol KW - Glutaraldehyde KW - Linker KW - Bioconjugation KW - Self-assembled monolayer (SAM) KW - Periodate oxidation KW - Reductive amination KW - Antibodies KW - Igg KW - Immunoglobulins KW - Carrier KW - Solid phase KW - Hyperbranched polymer KW - Aromatic amino acid analysis aaaa PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-555142 DO - https://doi.org/10.20944/preprints202208.0004.v1 SN - 2310-287X SP - 1 EP - 13 PB - MDPI CY - Basel AN - OPUS4-55514 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bahlmann, Arnold A1 - Carvalho, José Joao A1 - Weller, Michael G. A1 - Panne, Ulrich A1 - Schneider, Rudolf T1 - Immunoassays as high-throughput tools: monitoring spatial and temporal variations of carbamazepine, caffeine and cetirizine in surface and wastewaters N2 - Carbamazepine (CBZ), caffeine and cetirizine were monitored by enzyme-linked immunosorbent assays (ELISAs) in surface and wastewaters from Berlin, Germany. This fast and cost-efficient method enabled to assess the spatial and temporal variation of these anthropogenic markers in a high-throughput screening. CBZ and cetirizine were detected by the same antibody, which selectively discriminates between both compounds depending on the pH value used in the incubation step. To our best knowledge, this is the first dual-analyte immunoassay working with a single antibody. The frequent sampling with 487 samples being processed allowed for the repeated detection of unusually high concentrations of CBZ and caffeine. ELISA results correlate well with the ones obtained by liquid chromatography tandem mass spectrometry (LC-MS/MS). Caffeine concentrations found in surface waters were elevated by combined sewer overflows after stormwater events. During the hay fever season, the concentrations of the antihistamine drug cetirizine increased in both surface and wastewaters. Caffeine was almost completely removed during wastewater treatment, while CBZ and cetirizine were found to be more persistent. The maximum concentrations of caffeine, CBZ and cetirizine found in influent wastewater by LC–MS/MS were 470, 5.0 and 0.49 µg L-1, while in effluent wastewater the concentrations were 0.22, 4.5 and 0.51 µg L-1, respectively. For surface waters, concentrations up to 3.3, 4.5 and 0.72 µg L-1 were found, respectively. KW - ELISA KW - Carbamazepine KW - Caffeine KW - Cetirizine KW - Environmental monitoring KW - Anthropogenic markers PY - 2012 DO - https://doi.org/10.1016/j.chemosphere.2012.05.020 SN - 0045-6535 SN - 0366-7111 VL - 89 IS - 11 SP - 1278 EP - 1286 PB - Elsevier Science CY - Kidlington, Oxford AN - OPUS4-26187 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Waiblinger, H. U. A1 - Bartsch, D. A1 - Brockmeyer, J. A1 - Bruenen-Nieweler, C. A1 - Busch, U. A1 - Haase, I. A1 - Hahn, A. A1 - Haarmann, M. A1 - Hauser, W. A1 - Huber, I. A1 - Jany, K. D. A1 - Kirmse, N. A1 - Lindeke, S. A1 - Neumann, K. A1 - Naumann, H. A1 - Paschke, A. A1 - Pietsch, K. A1 - Pöpping, B. A1 - Reiting, R. A1 - Schroeder, U. A1 - Schwägele, F. A1 - Weller, Michael G. A1 - Zagon, J. T1 - Methods of differentiating animal species in food - Status quo N2 - In the field of animal species differentiation, work on standardizing methods has been intensified in Germany in recent years, not least due to the horsemeat scandal in 2013. Even though there are now hardly ever any positive findings anymore in examinations to detect horse adulterations in foods such as lasagne, animal species differentiation altogether ranks high in detecting adulteration of foods. This article, therefore, summarises the current status of analytical techniques used in Germany with standardization at German level. It has been established by the working group "Biochemical and Molecular Biological Analytics" of the Lebensmittelchemische Gesellschaft (Food Chemistry Society within the German Chemical Society) with support of experts in the working group “Molecular biology techniques for differentiating plant and animal species" (§64 of the German Food and Feed Code - LFGB) and the "Immunology and molecular biology" task force of the food hygiene and food of animal origin working group (ALTS), both from Germany. KW - Animal species differentiation KW - Fish species KW - PCR KW - ELISA KW - LC-MS/MS PY - 2017 IS - 3 SP - 29 EP - 36 PB - Deutscher Fachverlag GmbH CY - Frankfurt am Main AN - OPUS4-43485 LA - mul AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Reinmuth-Selzle, K. A1 - Tchipilov, Teodor A1 - Backes, A. T. A1 - Tscheuschner, Georg A1 - Tang, K. A1 - Ziegler, K. A1 - Lucas, K. A1 - Pöschl, U. A1 - Fröhlich-Nowoisky, J. A1 - Weller, Michael G. T1 - Determination of the protein content of complex samples by aromatic amino acid analysis, liquid chromatography-UV absorbance, and colorimetry N2 - Fast and accurate determination of the protein content of a sample is an important and non-trivial task of many biochemical, biomedical, food chemical, pharmaceutical, and environmental research activities. Different methods of total protein determination are used for a wide range of proteins with highly variable properties in complex matrices. These methods usually work reasonably well for proteins under controlled conditions, but the results for non-standard and complex samples are often questionable. Here, we compare new and well-established methods, including traditional amino acid analysis (AAA), aromatic amino acid analysis (AAAA) based on the amino acids phenylalanine and tyrosine, reversed-phase liquid chromatography of intact proteins with UV absorbance measurements at 220 and 280 nm (LC-220, LC-280), and colorimetric assays like Coomassie Blue G-250 dye-binding assay (Bradford) and bicinchoninic acid (BCA) assay. We investigated different samples, including proteins with challenging properties, chemical modifications, mixtures, and complex matrices like air particulate matter and pollen extracts. All methods yielded accurate and precise results for the protein and matrix used for calibration. AAA, AAAA with fluorescence detection, and the LC-220 method yielded robust results even under more challenging conditions (variable analytes and matrices). These methods turned out to be well-suited for reliable determination of the protein content in a wide range of samples, such as air particulate matter and pollen. KW - Air particulate matter KW - Aromatic amino acid analysis KW - Atmospheric aerosol KW - Chemical protein modification KW - Derivatization KW - Nitration KW - Nitrotyrosine KW - LC-UV absorbance KW - Pollen extract KW - Protein quantification KW - Protein test KW - Kjeldahl KW - Tyrosine KW - Phenylalanine KW - Hydrolysis KW - Bradford KW - BCA test KW - 280 nm KW - Air filter samples KW - Fluorescence KW - HPLC KW - Chromatography KW - Protein content KW - 150th anniversary of BAM KW - Topical collection: Analytical Methods and Applications in the Materials and Life Sciences PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-545924 UR - https://pubmed.ncbi.nlm.nih.gov/35320366/ DO - https://doi.org/10.1007/s00216-022-03910-1 SP - 1 EP - 14 PB - Springer Nature Limited CY - New York, Heidelberg AN - OPUS4-54592 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - INPR A1 - Paul, Martin A1 - Weller, Michael G. T1 - Antibody screening by microarray technology – Direct identification of selective high-affinity clones N2 - The primary screening of hybridoma cells is a time-critical and laborious step during the development of monoclonal antibodies. Often critical errors occur in this phase, which supports the notion that the generation of monoclonal antibodies with hybridoma technology is difficult to control and hence a risky venture. We think that it is crucial to improve the screening process to eliminate most of the immanent deficits of the conventional approach. With this new microarray-based procedure, several advances could be achieved: Selectivity for excellent binders, high throughput, reproducible signals, avoidance of misleading avidity (multivalency) effects, and simultaneous performance of competition experiments. The latter can directly be used to select clones of desired cross-reactivity properties. In this paper, a model system with two excellent clones against carbamazepine, two weak clones and blank supernatant has been designed to examine the effectiveness of the new system. The excellent clones could be detected largely independent of the IgG concentration, which is unknown during the clone screening since the determination and subsequent adjustment of the antibody concentration is not possible in most cases. Furthermore, in this approach, the enrichment, isolation, and purification of IgG for characterization is not necessary. Raw cell culture supernatant can be used directly, even when fetal calf serum (FCS) or other complex media had been used. In addition, an improved method for the oriented antibody-immobilization on epoxy-silanized slides is presented. Based on the results of this model system, we conclude that this approach should be preferable to most other protocols leading to many of false positives, causing expensive and lengthy confirmation steps to weed out the poor clones. KW - Hybridoma KW - Monoclonal Antibodies KW - Clones KW - Competitive Immunoassay KW - Hapten Immunoassay KW - False Positives PY - 2019 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-506621 DO - https://doi.org/10.20944/preprints201911.0023.v1 SN - 2310-287X SP - 1 EP - 17 PB - MDPI CY - Basel AN - OPUS4-50662 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Weller, Michael G. T1 - Drone-Based Localization of Hazardous Chemicals by Passive Smart Dust N2 - Rapid detection and localization of hazardous chemicals is crucial for environmental monitoring, occupational safety, and emergency response. This study presents a novel approach that combines drone technology with passive smart dust – biodegradable, paper-based chemical sensors – to remotely identify and map hazardous substances. In contrast to conventional smart dust concepts based on electronic microsensors with significant limitations in power supply, cost and environmental impact, this method uses cellulose-based, confetti-like sensors impregnated with colorimetric or fluorescent indicators. These sensors change color in response to chemical exposure, enabling simple optical detection from a distance. A drone equipped with a conventional digital camera takes pictures of the deployed sensors, which are then analyzed by automated image processing. The system converts images from the red-green-blue color model (RGB) into hue-saturation-value space (HSV) and applies threshold filters and clustering algorithms to increase the accuracy of identifying hazardous zones. Field tests using thymol blue as a pH-sensitive indicator have successfully demonstrated the system's ability to detect and locate acid spills in an outdoor environment. The results confirmed that low-cost, off-the-shelf drones can effectively monitor affected areas by providing real-time data for responders while minimizing human exposure to hazardous chemicals. This approach offers a fast, scalable, cost-effective and environmentally friendly alternative to conventional hazard detection technologies. Other important advantages are the close proximity of the sensors to the contamination, the avoidance of downwash problems by the drone propellers and the generation of a dense mesh of data points. Since no complex electronic sensors are required and simple, biodegradable materials are used, the system is well suited for large-scale deployment in industrial accidents, environmental pollution and chemical disaster scenarios. Future research will investigate additional chemical indicators to expand detection capabilities, optimize sensor deployment, and refine data processing for greater accuracy. The passive smart dust system represents a new concept in remote chemical hazard monitoring and may have broad implications for accident response, environmental crime, facility security, and attacks with chemical weapons. N2 - Die schnelle Erkennung und Lokalisierung gefährlicher Chemikalien ist für die Umweltüberwachung, den Arbeitsschutz und den Katastrophenschutz von entscheidender Bedeutung. Diese Studie stellt einen neuartigen Ansatz vor, der Drohnen-Technologie mit Passivem Smart Dust – biologisch abbaubaren, papierbasierten chemischen Sensoren – kombiniert, um gefährliche Substanzen aus der Ferne zu identifizieren und zu kartieren. Im Gegensatz zu herkömmlichen Smart-Dust-Konzepten, die auf elektronischen Mikrosensoren mit erheblichen Einschränkungen bei der Stromversorgung, den Kosten und der Umweltbelastung basieren, verwendet diese Methode zellulosebasierte, konfetti-artige Sensoren, die mit kolorimetrischen oder fluoreszierenden Indikatoren imprägniert sind. Diese Sensoren ändern ihre Farbe bei Kontakt mit Chemikalien, sodass eine einfache optische Erkennung aus der Ferne möglich ist. Eine Drohne, die mit einer herkömmlichen Digitalkamera ausgestattet ist, nimmt Bilder der eingesetzten Sensoren auf, die dann durch automatisierte Bildverarbeitung analysiert werden. Das System konvertiert Bilder vom Rot-Grün-Blau-Farbmodell (RGB) in den Farbton-Sättigungs-Wert-Raum (HSV) und wendet Schwellenwertfilter und Clustering-Algorithmen an, um die Genauigkeit bei der Identifizierung gefährlicher Zonen zu erhöhen. Feldtests mit Thymolblau als pH-empfindlichem Indikator haben erfolgreich die Fähigkeit des Systems nachgewiesen, ausgelaufene Säure in Außenbereichen zu erkennen und zu lokalisieren. Die Ergebnisse bestätigen, dass kostengünstige, handelsübliche Drohnen betroffene Bereiche effektiv überwachen können, indem sie Einsatzkräften Echtzeitdaten liefern und gleichzeitig die Exposition von Menschen gegenüber gefährlichen Chemikalien minimieren. Dieser Ansatz bietet eine schnelle, skalierbare, kostengünstige und umweltfreundliche Alternative zu herkömmlichen Technologien zur Gefahrenerkennung. Weitere wichtige Vorteile sind die räumliche Nähe der Sensoren zur Kontamination, die Vermeidung von Abwindproblemen durch die Drohnenpropeller und die Erzeugung eines dichten Netzes von Datenpunkten. Da keine komplexen elektronischen Sensoren erforderlich sind und einfache, biologisch abbaubare Materialien verwendet werden, eignet sich das System gut für den großflächigen Einsatz bei Industrieunfällen, Umweltverschmutzung und chemischen Katastrophenszenarien. In zukünftigen Forschungsarbeiten sollen weitere chemische Indikatoren untersucht werden, um die Erkennungsmöglichkeiten zu erweitern, den Sensoreinsatz zu optimieren und die Datenverarbeitung für eine höhere Genauigkeit zu verfeinern. Das passive Smart-Dust-System stellt ein neues Konzept für die Fernüberwachung chemischer Gefahren dar und könnte weitreichende Auswirkungen auf die Unfallbekämpfung, Umweltkriminalität, Anlagensicherheit und Angriffe mit Chemiewaffen haben. T2 - 39th Session of the Scientific Advisory Board of the OPCW CY - The Hague, Netherlands DA - 01.04.2025 KW - Imaging KW - Remote Sensing KW - Chemosensors KW - Organization for the Prohibition of Chemical Weapons (OPCW) KW - CBRN Defence PY - 2025 AN - OPUS4-62897 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schwarz, Gunnar A1 - Beck, S. A1 - Weller, Michael G. A1 - Linscheid, M.W. T1 - MeCAT - new iodoacetamide reagents for metal labeling of proteins and peptides N2 - Besides protein identification via mass spectrometric methods, protein and peptide quantification has become more and more important in order to tackle biological questions. Methods like differential gel electrophoresis or enzyme-linked immunosorbent assays have been used to assess protein concentrations, while stable isotope labeling methods are also well established in quantitative proteomics. Recently, we developed metalcoded affinity tagging (MeCAT) as an alternative for accurate and sensitive quantification of peptides and proteins. In addition to absolute quantification via inductively coupled plasma mass spectrometry, MeCAT also enables sequence analysis via electrospray ionization tandem mass spectrometry. In the current study, we developed a new labeling approach utilizing an iodoacetamide MeCAT reagent (MeCAT-IA). The MeCAT-IA approach shows distinct advantages over the previously used MeCAT with maleinimide reactivity such as higher labelling efficiency and the lack of diastereomer formation during labeling. Here, we present a careful characterization of this new method focusing on the labeling process, which yields complete tagging with an excess of reagent of 1.6 to 1, less complex chromatographic behavior, and fragmentation characteristics of the tagged peptides using the iodoacetamide MeCAT reagent. KW - Quantitative proteomics KW - Mass spectrometry KW - Metal labeling KW - Stable isotope labeling KW - Lanthanide DOTA KW - Metall-Markierung KW - Reagenzien KW - Protein-Quantifizierung KW - Lanthaniden KW - Multiplexing PY - 2011 DO - https://doi.org/10.1007/s00216-011-5189-7 SN - 1618-2642 SN - 1618-2650 VL - 401 IS - 4 SP - 1203 EP - 1209 PB - Springer CY - Berlin AN - OPUS4-23949 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Waiblinger, H. U. A1 - Brockmeyer, J. A1 - Bruenen-Nieweler, C. A1 - Busch, U. A1 - Haase, I. A1 - Hahn, A. A1 - Haarmann, M. A1 - Hauser, W. A1 - Huber, I. A1 - Jany, K. D. A1 - Kirmse, N. A1 - Lindeke, S. A1 - Neumann, K. A1 - Naumann, H. A1 - Paschke, A. A1 - Pietsch, K. A1 - Pöpping, B. A1 - Reiting, R. A1 - Schroeder, U. A1 - Schwägele, F. A1 - Weller, Michael G. A1 - Zagon, J. T1 - Methoden zur Differenzierung von Tierarten in Lebensmitteln – Status quo N2 - Nicht zuletzt bedingt durch den Pferdefleischskandal im Jahr 2013 wurden in Deutschland die Aktivitäten bei der Methodenstandardisierung im Bereich der Tierarten-Differenzierung in den vergangenen Jahren intensiviert. Wenn auch positive Befunde bei dem Nachweis von Bestandteilen aus Pferd in Lebensmitteln wie Lasagne derzeit so gut wie nicht mehr anzutreffen sind, so hat die Tierartendifferenzierung insgesamt beim Nachweis von Verfälschungen in Lebensmitteln einen hohen Stellenwert. Diese Arbeit fasst daher den aktuellen Stand der Analytik in Deutschland mit Schwerpunkt bei der Standardisierung zusammen. Sie wurde erstellt durch die Arbeitsgruppe „Biochemische und molekularbiologische Analytik“ der Lebensmittelchemischen Gesellschaft mit Unterstützung von Experten der Arbeitsgruppe „Molekularbiologische Methoden zur Pflanzen- und Tierartendifferenzierung“ (§ 64 LFGB) sowie der ALTS-Arbeitsgruppe „Immunologie und Molekularbiologie“ (jeweils D). KW - ELISA KW - PCR KW - Multiplex KW - DNA-Chip KW - Fischarten KW - Standardisierung KW - Molekularbiologie KW - Immunoassay KW - Hybridisierung KW - Digitale PCR KW - LC-MS/MS KW - Massenspektrometrie KW - Schnellmethoden KW - Screening KW - Milch KW - Microarray KW - LAMP KW - Laborvergleichuntersuchungen KW - Referenzmaterialien KW - Standardverfahren PY - 2017 SN - 0015-363X IS - 1 SP - 97 EP - 102 PB - Deutscher Fachverlag GmbH CY - Frankfurt AN - OPUS4-39038 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Weller, Michael G. T1 - Challenges of protein analysis N2 - Selected Projects BAM Division 1.5 Test for sensitive SARS-CoV-2 detection Corundum as a novel affinity support Troponin biosensor based on chemiluminescence Plant virus purification (CCMV) Protein Quantification by 1H-NMR Ultra-miniaturized Biosensors N2 - Ausgewählte Projekte BAM-Abteilung 1.5 Test für empfindlichen SARS-CoV-2-Nachweis Korund als neuartige Affinitätscarriermaterialien Troponin-Biosensor auf Basis von Chemilumineszenz Reinigung von Pflanzenviren (CCMV) Proteinquantifizierung durch 1H-NMR Ultra-miniaturisierte Biosensoren T2 - Klausurtagung der MPI Abteilung „Multiphasenchemie“ CY - Mainz, Germany DA - 19.11.2024 KW - Corona test KW - Corundum KW - Affinity separation KW - Affinity chromatography KW - Troponin biosensor KW - Peptide aptamer KW - Cowpea chlorotic mottle virus KW - Nanoparticle KW - Nanocarrier KW - Nuclear magnetic resonance NMR KW - Protein quantification KW - HyPhox KW - Ring resonator PY - 2024 AN - OPUS4-62126 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Liu, F. A1 - Lakey, P. S. J. A1 - Berkemeier, T. A1 - Tong, H. A1 - Kunert, A. T. A1 - Meusel, H. A1 - Cheng, Y. A1 - Su, H. A1 - Fröhlich-Nowoisky, J. A1 - Lai, S. A1 - Weller, Michael G. A1 - Shiraiwa, M. A1 - Pöschl, U. A1 - Kampf, C. J. T1 - Atmospheric protein chemistry influenced by anthropogenic air pollutants: nitration and oligomerization upon exposure to ozone and nitrogen dioxide N2 - The allergenic potential of airborne proteins may be enhanced via post-translational modification induced by air pollutants like ozone (O3) and nitrogen dioxide (NO2). The molecular mechanisms and kinetics of the chemical modifications that enhance the allergenicity of proteins, however, are still not fully understood. Here, protein tyrosine nitration and oligomerization upon simultaneous exposure of O3 and NO2 were studied in coated-wall flow-tube and bulk solution experiments under varying atmospherically relevant conditions (5–200 ppb O3, 5–200 ppb NO2, 45–96% RH), using bovine serum albumin as a model protein. Generally, more tyrosine residues were found to react via the nitration pathway than via the oligomerization pathway. Depending on reaction conditions, oligomer mass fractions and nitration degrees were in the ranges of 2.5–25% and 0.5–7%, respectively. The experimental results were well reproduced by the kinetic multilayer model of aerosol surface and bulk chemistry (KM-SUB). The extent of nitration and oligomerization strongly depends on relative humidity (RH) due to moisture-induced phase transition of proteins, highlighting the importance of cloud processing conditions for accelerated protein chemistry. Dimeric and nitrated species were major products in the liquid phase, while protein oligomerization was observed to a greater extent for the solid and semi-solid phase states of proteins. Our results show that the rate of both processes was sensitive towards ambient ozone concentration but rather insensitive towards different NO2 levels. An increase of tropospheric ozone concentrations in the Anthropocene may thus promote pro-allergic protein modifications and contribute to the observed increase of allergies over the past decades. KW - Oxidation KW - Nitration KW - Cross-linking KW - Ozone KW - Nitrogen dioxide KW - Dimer KW - Air pollution KW - Diesel KW - Aeroallergens KW - Pollen KW - Tyrosine KW - Nitrotyrosine KW - BSA KW - Albumin PY - 2017 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-418482 DO - https://doi.org/10.1039/c7fd00005g SN - 1359-6640 VL - 200 SP - 413 EP - 427 PB - Royal Society of Chemistry CY - London AN - OPUS4-41848 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Weller, Michael G. T1 - Referee Report 06 March 2017 N2 - This article is a valuable and welcome contribution to the ongoing discussion of antibody quality. The suggestion of a two-tier approach is helpful to distinguish between simple descriptive data and the validation of an antibody for a specified application. KW - Antibody KW - Validation PY - 2017 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-393333 UR - https://f1000research.com/articles/6-161/v1#referee-response-20349 DO - https://doi.org/10.5256/f1000research.11700.r20349 SN - 2046-1402 SP - 6 EP - 7 PB - F1000 Research Ltd. CY - London AN - OPUS4-39333 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Liu, F. A1 - Lai, S. A1 - Tong, H. A1 - Lakey, P. S. J. A1 - Shiraiwa, M. A1 - Weller, Michael G. A1 - Pöschl, U. A1 - Kampf, C. J. T1 - Release of free amino acids upon oxidation of peptides and proteins by hydroxyl radicals N2 - Hydroxyl radical-induced oxidation of proteins and peptides can lead to the cleavage of the peptide, leading to a release of fragments. Here, we used high-performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS) and pre-column online ortho-phthalaldehyde (OPA) derivatization-based amino acid analysis by HPLC with diode array detection and fluorescence detection to identify and quantify free amino acids released upon oxidation of proteins and peptides by hydroxyl radicals. Bovine serum albumin (BSA), ovalbumin (OVA) as model proteins, and synthetic tripeptides (comprised of varying compositions of the amino acids Gly, Ala, Ser, and Met) were used for reactions with hydroxyl radicals, which were generated by the Fenton reaction of iron ions and hydrogen peroxide. The molar yields of free glycine, aspartic acid, asparagine, and alanine per peptide or protein varied between 4 and 55%. For protein oxidation reactions, the molar yields of Gly (∼32-55% for BSA, ∼10-21% for OVA) were substantially higher than those for the other identified amino acids (∼5-12% for BSA, ∼4-6% for OVA). Upon oxidation of tripeptides with Gly in C-terminal, mid-chain, or N-terminal positions, Gly was preferentially released when it was located at the C-terminal site. Overall, we observe evidence for a site-selective formation of free amino acids in the OH radical-induced oxidation of peptides and proteins, which may be due to a reaction pathway involving nitrogen-centered radicals. KW - Peptides KW - Proteins KW - Oxidation KW - Hydroxyl radicals KW - LC-MS KW - Amino acid analysis KW - Bovine serum albumin KW - Ovalbumin KW - Tripeptides KW - Ortho-Phthalaldehyde KW - AAA KW - Degradation KW - Fragmentation KW - Mechanism PY - 2017 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-398714 UR - http://link.springer.com/article/10.1007%2Fs00216-017-0188-y DO - https://doi.org/10.1007/s00216-017-0188-y SN - 1618-2650 SN - 1618-2642 VL - 409 IS - 9 SP - 2411 EP - 2420 PB - Springer CY - Heidelberg AN - OPUS4-39871 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Scherz, Franziska A1 - Krop, U. A1 - Monks, K. A1 - Weller, Michael G. T1 - Antikörperreinigung mit Glasmonolithen - Vereinfachung von Affinitätstrennungen mit HPLC-Systemen N2 - Druckstabile Glasmonolithen ermöglichen eine schnelle und unkomplizierte Reinigung von Antikörpern, z.B. aus Serum oder Zellkulturüberständen. Die sehr gute Regenerierbarkeit lässt eine lange Lebensdauer der Säulen erwarten, was die Kosten pro Probe niedrig hält. KW - Borosilicatglas KW - Immunglobuline KW - IgG KW - Serum KW - Plasma KW - Protein A KW - Protein G KW - Affinitätschromatographie KW - Agarose KW - Carrier-Material KW - Stationäre Phase KW - Immobilisierung KW - Highspeed KW - Trennung KW - Reinigung KW - Downstream Processing PY - 2018 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-445330 UR - http://www.git-labor.de/forschung/materialien/antikoerperreinigung-mit-glasmonolithen SN - 0016-3538 VL - 62 IS - 3 SP - 24 EP - 25 PB - Wiley-VCH Verlag GmbH & Co. KGaA CY - Weinheim AN - OPUS4-44533 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Weller, Michael G. T1 - Interview with Dr Michael G. Weller N2 - This author interview is by Dr Michael G. Weller, Head of Division 1.5 Protein Analysis at Federal Institute for Materials Research and Testing (BAM). BAM (www.bam.de/en) is a senior scientific and technical institute with responsibility to the German Federal Ministry for Economic Affairs and Energy. Dr Weller's review paper, Quality issues of research antibodies is available for download in Analytical Chemistry Insights. KW - Antibodies KW - Quality KW - Reproducibility PY - 2016 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-392326 UR - http://insights.sagepub.com/la_press_news.php?pa=view&news_item_id=4025 SP - 1 PB - SAGE CY - London AN - OPUS4-39232 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Nerger, Tino A1 - Neumann, Patrick P. A1 - Weller, Michael G. T1 - Drone-Based Localization of Hazardous Chemicals by Passive Smart Dust N2 - The distribution of tiny sensors over a specific area was first proposed in the late 1990s as a concept known as smart dust. Several efforts focused primarily on computing and networking capabilities, but quickly ran into problems related to power supply, cost, data transmission, and environmental pollution. To overcome these limitations, we propose using paper-based (confetti-like) chemosensors that exploit the inherent selectivity of chemical reagents, such as colorimetric indicators. In this work, cheap and biodegradable passive sensors made from cellulose could successfully indicate the presence of hazardous chemicals, e.g., strong acids, by a significant color change. A conventional color digital camera attached to a drone could easily detect this from a safe distance. The collected data were processed to define the hazardous area. Our work presents a combination of the smart dust concept, chemosensing, paper-based sensor technology, and low-cost drones for flexible, sensitive, economical, and rapid detection of hazardous chemicals in high-risk scenarios. KW - Cellulose KW - Passive Smart Dust KW - Drohne KW - Kolorimetrische Sensoren PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-614641 DO - https://doi.org/10.3390/s24196195 VL - 24 IS - 19 SP - 1 EP - 16 PB - MDPI AN - OPUS4-61464 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Tscheuschner, Georg A1 - Ponader, Marco A1 - Raab, Christopher A1 - Weider, Prisca S. A1 - Hartfiel, Reni A1 - Kaufmann, Jan Ole A1 - Völzke, Jule L. A1 - Bosc-Bierne, Gaby A1 - Prinz, Carsten A1 - Schwaar, T. A1 - Andrle, Paul A1 - Bäßler, Henriette A1 - Nguyen, Khoa A1 - Zhu, Y. A1 - Mey, A. S. J. S. A1 - Mostafa, A. A1 - Bald, I. A1 - Weller, Michael G. T1 - Efficient Purification of Cowpea Chlorotic Mottle Virus by a Novel Peptide Aptamer N2 - The cowpea chlorotic mottle virus (CCMV) is a plant virus explored as a nanotechnological platform. The robust self-assembly mechanism of its capsid protein allows for drug encapsulation and targeted delivery. Additionally, the capsid nanoparticle can be used as a programmable platform to display different molecular moieties. In view of future applications, efficient production and purification of plant viruses are key steps. In established protocols, the need for ultracentrifugation is a significant limitation due to cost, difficult scalability, and safety issues. In addition, the purity of the final virus isolate often remains unclear. Here, an advanced protocol for the purification of the CCMV from infected plant tissue was developed, focusing on efficiency, economy, and final purity. The protocol involves precipitation with PEG 8000, followed by affinity extraction using a novel peptide aptamer. The efficiency of the protocol was validated using size exclusion chromatography, MALDI-TOF mass spectrometry, reversed-phase HPLC, and sandwich immunoassay. Furthermore, it was demonstrated that the final eluate of the affinity column is of exceptional purity (98.4%) determined by HPLC and detection at 220 nm. The scale-up of our proposed method seems to be straightforward, which opens the way to the large-scale production of such nanomaterials. This highly improved protocol may facilitate the use and implementation of plant viruses as nanotechnological platforms for in vitro and in vivo applications. N2 - Das Cowpea Chlorotic Mottle Virus (CCMV) ist ein Pflanzenvirus, das als nanotechnologische Plattform erforscht wird. Der robuste Selbstorganisationsmechanismus seines Kapsidproteins ermöglicht die Verkapselung und gezielte Abgabe von Medikamenten. Darüber hinaus kann das Kapsid-Nanopartikel als programmierbare Plattform für die Präsentation verschiedener molekularer Komponenten verwendet werden. Im Hinblick auf künftige Anwendungen ist eine effiziente Produktion und Reinigung von Pflanzenviren von entscheidender Bedeutung. In etablierten Protokollen stellt die notwendige Ultrazentrifugation aufgrund von Kosten, schwieriger Skalierbarkeit und Sicherheitsaspekten eine erhebliche Einschränkung dar. Darüber hinaus bleibt die Reinheit des endgültigen Virusisolats oft unklar. Hier wurde ein fortschrittliches Protokoll für die Reinigung von CCMV aus infiziertem Pflanzengewebe entwickelt, wobei der Schwerpunkt auf Effizienz, Wirtschaftlichkeit und Reinheit lag. Das Protokoll beinhaltet eine Fällung mit Polyethylenglycol (PEG 8000), gefolgt von einer Affinitätsextraktion mit einem neuartigen Peptid-Aptamer. Die Effizienz des Protokolls wurde mithilfe von Größenausschluss-Chromatographie (SEC), MALDI-TOF-Massenspektrometrie, Umkehrphasen-HPLC und Sandwich-Immunoassay validiert. Darüber hinaus wurde nachgewiesen, dass das endgültige Eluat der Affinitätssäule eine außergewöhnliche Reinheit (98,4 %) aufweist, die durch HPLC und Detektion bei 220 nm bestimmt wurde. Die Skalierung der von uns vorgeschlagenen Methode scheint einfach zu sein, was den Weg für eine größer angelegte Produktion solcher Nanomaterialien ebnet. Dieses stark verbesserte Protokoll könnte die Verwendung und Umsetzung von Pflanzenviren als nanotechnologische Plattformen für In-vitro- und In-vivo-Anwendungen erleichtern. KW - Affinity chromatography KW - Nanoparticles KW - Nanoscience KW - Carrier protein KW - Encapsulation KW - Combinatorial peptide library KW - Peptide binder KW - Vigna unguiculata KW - Augenbohne KW - Schlangenbohne KW - Pflanzenvirus KW - Plant virus KW - Upscaling KW - Commercialization KW - Reference material KW - Nanocarrier PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-572645 DO - https://doi.org/10.3390/v15030697 VL - 15 IS - 3 SP - 1 EP - 24 PB - MDPI CY - Basel, Schweiz AN - OPUS4-57264 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Beslic, D. A1 - Tscheuschner, Georg A1 - Renard, B. Y. A1 - Weller, Michael G. A1 - Muth, Thilo T1 - Comprehensive evaluation of peptide de novo sequencing tools for monoclonal antibody assembly N2 - Monoclonal antibodies are biotechnologically produced proteins with various applications in research, therapeutics and diagnostics. Their ability to recognize and bind to specific molecule structures makes them essential research tools and therapeutic agents. Sequence information of antibodies is helpful for understanding antibody–antigen interactions and ensuring their affinity and specificity. De novo protein sequencing based on mass spectrometry is a valuable method to obtain the amino acid sequence of peptides and proteins without a priori knowledge. In this study, we evaluated six recently developed de novo peptide sequencing algorithms (Novor, pNovo 3, DeepNovo, SMSNet, PointNovo and Casanovo), which were not specifically designed for antibody data. We validated their ability to identify and assemble antibody sequences on three multi-enzymatic data sets. The deep learning-based tools Casanovo and PointNovo showed an increased peptide recall across different enzymes and data sets compared with spectrum-graph-based approaches. We evaluated different error types of de novo peptide sequencing tools and their performance for different numbers of missing cleavage sites, noisy spectra and peptides of various lengths. We achieved a sequence coverage of 97.69–99.53% on the light chains of three different antibody data sets using the de Bruijn assembler ALPS and the predictions from Casanovo. However, low sequence coverage and accuracy on the heavy chains demonstrate that complete de novo protein sequencing remains a challenging issue in proteomics that requires improved de novo error correction, alternative digestion strategies and hybrid approaches such as homology search to achieve high accuracy on long protein sequences. KW - De novo peptide sequencing KW - Bioinformatics KW - Benchmarking study KW - Monoclonal antibody KW - Mass spectrometry KW - Sequence coverage KW - Light chains KW - Heavy chains KW - IgG KW - Immunoglobulins KW - Error correction KW - Sequencing algorithm KW - Preprocessing KW - Missing fragmentation sites KW - Deep learning-based tools PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-570363 DO - https://doi.org/10.1093/bib/bbac542 VL - 24 IS - 1 SP - 1 EP - 12 PB - Oxford University Press AN - OPUS4-57036 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -