TY - CONF A1 - Miccoli, Lorenzo A1 - Fontana, Patrick A1 - Johansson, G. A1 - Zandi, K. A1 - Portal, Natalie Williams A1 - Müller, U. T1 - Numerical modelling of UHPC and TRC sandwich elements for building envelopes N2 - ln this paper a modelling approach is presented to reproduce the mechanical behaviour of sandwich panels via finite element analysis. Two types of panels were investigated in this scope of work. The first sandwich element was a textile reinforced concrete (TRC) panel with cellular lightweight concrete insulation and the second configuration was an ultra-high performances concrete (UHPC) panel with aerated autoclaved concrete insulation. The goal was to obtain a reliable numerical strategy that represents a reasonable compromise in terms of sufficient accuracy of the element characteristics and the computational costs. The results show the possibility of describing the composite action in a full sandwich panel. The achieved modelling approach will later be used for the optimization of TRC and UHPC panels in terms of minimizing the thickness, identifying the number and location of connectors, as well as evaluating varying anchorage Systems. T2 - IABSE conference - Structural engineering: Providing solutions to global challenges CY - Geneva, Switzerland DA - 23.09.2015 KW - Sandwich elements KW - Ultra-high performance concrete (UHPC) KW - Textile reinforced concrete (TRC) KW - Autoclaved aerated concrete (AAC) KW - Cellular lightweight concrete (CLC) KW - Finite element analysis (FEA) PY - 2015 SN - 978-3-85748-140-6 SP - 195 EP - 203 AN - OPUS4-34552 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Miccoli, Lorenzo A1 - Fontana, Patrick A1 - Silva, N. A1 - Klinge, A. A1 - Cederqvist, C. A1 - Kreft, O. A1 - Qvaeschning, D. A1 - Sjöström, C. T1 - Composite UHPC-AAC/CLC facade elements with modified interior plaster for new buildings and refurbishment N2 - The awareness of the environmental impact of the building sector is increasing. Steel reinforced concrete is the most commonly used construction material, though with a high-embodied energy and carbon footprint. Large environmental gains may arise if an alternative to steel reinforced concrete is developed. In this context, ultra-high performance concrete (UHPC) materials are shown to be promising alternatives with advantages such as lower embodied energy and reduced environmental impact. Predictions suggest that UHPC composite elements for building envelopes could have other benefits such as an increased service life, optimised use of building area due to thinner elements and minimised maintenance due to the absence of reinforcement or use of non-corrosive reinforcing materials such as carbon fibres. In the framework of the H-HOUSE project funded by the European Commission, composite elements are developed. The aim is to create facade panels combining an autoclaved aerated concrete or cellular lightweight concrete insulation layer with an external UHPC supporting layer. To enhance occupant comfort and health, hygroscopic materials that are capable to buffer indoor air humidity shall be applied to the inside of such elements. Indoor air humidity levels are expected to be more stable, which shall subsequently improve the indoor climate and minimise potential decay to the construction. T2 - ICAE 2015 - 7th International congress on architectural envelopes CY - San Sebastián, Spain DA - 27.05.2015 KW - Composite panels KW - Ultra-high performance concrete (UHPC) KW - Autoclaved aerated concrete (AAC) KW - Cellular lightweight concrete ^ PY - 2015 SN - 978-84-88734-10-5 SP - 297 EP - 305 AN - OPUS4-33572 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Fontana, Patrick A1 - Miccoli, Lorenzo A1 - Kocadag, R. A1 - Silva, N. A1 - Qvaesching, D. A1 - Kreft, O. A1 - Cederqvist, Ch. ED - Fehling, E. ED - Middendorf, B. ED - Thiemicke, J. T1 - Composite UHPC facade elements with functional surfaces N2 - This paper presents an innovative way to combine an external ultra-high performance concrete (UHPC) supporting layer with an insulation layer of autoclaved aerated concrete (AAC) or cellular lightweight concrete (CLC) to create light-weight façade elements, which are improved in functionality and in energy efficiency. The durability of the façade elements is improved by developing UHPC with self-cleaning properties. One approach is based on the photocatalytic activation of the external UHPC shell by incorporation of TiO2 particles. The second approach consists of the modification of the UHPC surface by micro structuring in combination with the application of water-repellent agents to create durable super hydrophobicity. The current results obtained from laboratory testing are promising and demonstrate the feasibility of the approaches. T2 - HiPerMat 2016 4th International Symposium on Ultra-High Performance Concrete and High Performance Construction Materials CY - Kassel, Germany DA - 09.03.2016 KW - Composite UHPC elements KW - photocatalysis KW - super hydrophobicity KW - self-cleaning KW - autoclaved aerated concrete KW - cellular lightweight concrete PY - 2016 SN - 978-3-7376-0094-1 VL - 27 SP - 159 EP - 160 PB - kassel university press GmbH CY - Kassel AN - OPUS4-36566 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, P. A1 - Miccoli, Lorenzo A1 - Fontana, Patrick A1 - Ziegert, Ch. T1 - Partial safety factors for earth block masonry N2 - In the beginning of the 1980s earth building has undergone a renaissance, which nowadays leads to an increasing use of load-bearing earth constructions and in particular, earth block masonry. At present, there are no common structural standards according to the semi-probabilistic design concept, which is the state-of-the-art in European standards. A solid database is needed for the determination of the partial safety factor on the resistance side. Therefore, compressive strength tests were carried out with two types of earth blocks and two types of prefabricated earth mortar. The evaluation showed that the variation of the compressive strength was remarkably less than expected, which seems to indicate high quality standards of the components earth block and mortar with regard to industrial production. On the basis of these results and together with the reliability method, a partial safety factor for earth block masonry subjected to compression was determined. The main aim of the research was the development of a first valid database for material parameters of earth block masonry with particular regard to statistical characteristics. The results showed that a common calculation method for earth block masonry based on partial safety factors following the valid masonry construction standard is feasible. T2 - Terra Lyon 2016 - XIIth World Congress on Earthen Architecture CY - Lyon, France DA - 11.07.2016 KW - Safety factors KW - Earth block masonry KW - Compressive strength PY - 2016 SN - 979-10-96446-12-4 SP - 1 EP - 8 PB - Editions CRAterre CY - Villefontaine AN - OPUS4-45151 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Miccoli, Lorenzo A1 - Silva, R. A. A1 - Garofano, A. A1 - Oliveira, D. V. ED - Papadrakakis, M. ED - Fragiadakis, M. T1 - In-Plane behaviour of earthen materials: A numerical comparison between adobe masonry, rammed earth and cob N2 - The paper presents a comparison between different numerical modelling approaches aiming to simulate the in-plain behaviour of three types of earthen materials, namely adobe masonry, rammed earth and cob. For this purpose, uniaxial and diagonal compression tests were carried out, which allowed determining important mechanical parameters, such as compressive strength, Young’s modulus, Poisson’s ratio, shear strength and shear modulus. Furthermore, the tests allowed assessing the level of non-linear behaviour of the respective stress–strain relationships as well as the failure modes. The experimental results were then used for the calibration of numerical models (based on the finite element method) for simulating the non-linear behaviour of the earth materials under in-plane shear loading. Both macro- and micro-modelling approaches were considered for this purpose. The procedures adopted for model calibration established the reliability of various modelling strategies for the different loading conditions. The simplified Approach based on macromodelling shows a satisfactory accuracy and low computational costs. The results reproducing the uniaxial compression are in good correspondence with the post-elastic behaviour observed in the experimental campaign. The micro-modelling approach adopted to reproduce the shear behaviour, even with higher computational cost, represents a suitable tool to predict the adobe masonry and rammed earth collapse mechanisms. T2 - 6th International Conference on Computational Methods in Structural Dynamics and Earthquake Engineering (COMPDYN 2017) CY - Rhodes, Greece DA - 15.06.2017 KW - Earthen materials KW - Compression behaviour KW - Shear behaviour KW - Digital image corelation KW - Finite element method PY - 2017 SN - 978-618-82844-1-8 VL - 1 SP - 2478 EP - 2504 AN - OPUS4-42579 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Miccoli, Lorenzo A1 - Fontana, Patrick ED - Pena, F. ED - Chávez, M. T1 - Bond strength performances of anchor pins for earthen buildings. A comparison between earth block masonry, rammed earth and cob N2 - Connections improvement plays a key role in seismic upgrade of historical buildings. Their global response is related to the behavior of the single structural elements as well as to their mutual connections. Up to now only few data are available about the performance of grouted anchor pins in earthen materials where the critical point is the bond between the grout and the earthen substrate. In this paper, results of the experimental testing performed on earth block masonry, rammed earth and cob are presented. Pull-out tests were carried out to investigate the bond strength and failure modes of stainless steel rods with a lime based hydraulic grout and their compatibility with earthen materials. Rods with nuts were investigated to improve the pull-out capacity of the anchors. They showed higher pull-out capacity than rods without nuts. The performances of rods with nuts in cob were influenced by the rough surface at/of the earthen substrate. It is assumed that the non homogeneous surface caused an interlocking mechanism, which allowed to reach a pull-out capacity of about 54% higher than in earth block masonry. T2 - SAHC 2014 - 9th International conference on structural analysis of historical constructions CY - Mexiko City, Mexico DA - 14.10.2014 KW - Earthen materials KW - Pull-out tests KW - Anchor pins KW - Lime based hydraulic gout PY - 2014 SP - Paper-ID 07/011, 1-13 AN - OPUS4-32537 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Silva, R.A. A1 - Oliveira, D.V. A1 - Miccoli, Lorenzo A1 - Schueremans, L. ED - Pena, F. ED - Chávez, M. T1 - Modelling of rammed earth under shear loading N2 - The intensive use of earth as a building material since ancient times resulted in an important and significant earthen built heritage currently existing worldwide spread. The rammed earth technique has a significant presence in this heritage, where it served to build from simple dwell-ings to fortresses. However, the high vulnerability of rammed earth constructions to decay agents and to seismic events puts in risk their further existence and the lives of millions of peo-ple. With respect to the seismic behaviour of rammed earth walls, the understanding and mod-elling of their shear behaviour are topics underdeveloped in the bibliography. Nevertheless, these topics are of extreme importance in the preservation and strengthening of rammed earth constructions. Therefore, this paper presents a numerical work aiming at modelling the non-linear behaviour of unstabilised rammed earth under shear loading, resorting to the finite ele-ments method (FEM). The models were used to simulate the behaviour of a set of rammed earth wallets tested under diagonal compression. Both macro- and micro-modelling approach-es were considered, where the objective of this last approach was to evaluate the influence of apparent weakness of the interfaces between layers on the shear behaviour. The total strain ro-tating crack model (TSCRM) was used to simulate the behaviour of the rammed earth material, while the Mohr-Coulomb failure criterion was used to simulate the behaviour of interfaces be-tween layers. Furthermore, uncertainties related to the definition of the input parameters re-quired performing a sensitivity analysis. The numerical models achieved good agreement with the experimental results and the compressive strength, the Poisson’s ratio, the tensile strength and the tensile fracture energy revealed to be the most important parameters in the analyses. T2 - SAHC 2014 - 9th International conference on structural analysis of historical constructions CY - Mexiko City, Mexico DA - 14.10.2014 KW - Rammed earth KW - Diagonal-compression KW - Shear behaviour KW - FEM modelling PY - 2014 SP - Paper-ID 08/015, 1-12 AN - OPUS4-32538 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Miccoli, Lorenzo A1 - Garofano, A. A1 - Fontana, Patrick A1 - Müller, U. ED - Lourenco, P.B. ED - Haseltine, B.A. ED - Vasconcelos, G. T1 - Static behaviour of earth block masonry: experimental testing and finite element modelling N2 - In this paper an extensive research campaign aimed to define the mechanical performance of earth block masonry panels is presented. Uniaxial compression and diagonal compression tests were performed. The test results confirmed the brittle behaviour of earth block masonry under uniaxial compressive load and showed that the failure of earth block masonry under shear load occurs by sliding of the earth blocks along the mortar joints after initial cracking in mortar joints and earth blocks. For diagonal compression test results showed that building technique practice is one of the key factors affecting the structural performances. Experimental behaviour was modelled with a non-linear model capable of describing cracking behaviour. Both micro-modelling and macro-modelling implementing isotropic or orthotropic material laws were used to assess the reliability of different modelling strategies. The model calibration was carried out by sensibility analysis of the input parameters to understand the influence of unit strength on the shear behaviour of masonry. T2 - 9th IMC - International Masonry Conference CY - Guimaraes, Portugal DA - 07.07.2014 KW - Earthen materials KW - Compression test KW - Diagonal compression test KW - Numerical modelling KW - Earth block masonry KW - Uniaxial compression test PY - 2014 SN - 978-972-8692-85-8 SP - Paper ID 1484, 1 EP - 14 AN - OPUS4-31138 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Miccoli, Lorenzo A1 - Fontana, Patrick ED - Lourenco, P.B. ED - Haseltine, B.A. ED - Vasconcelos, G. T1 - Bond strength of anchor pins for earth block masonry N2 - Connections improvement plays a key role in seismic upgrade of historical buildings. Their global response is related to the behaviour of the single structural elements as well as by their mutual connections. Up to now limited data is available on the performance of grouted anchor pins in earthen materials where the critical point is the bond between the grout and the earthen substrate. In this paper results of the experimental testing performed on earth block masonry are presented. Pull-out tests were carried out to investigate the bond strength and failure modes of stainless steel as well as glass fiber reinforced polymer (GFRP) rods with a lime based hydraulic grout and their compatibility with earth block masonry. GFRP rods were investigated as an alternative bonded-in anchorage material to the commonly used steel. In comparison with steel, they have a reduced weight and a reduced coefficient of thermal expansion. Their lower modulus of elasticity seems to be more compatible with the modulus of elasticity of earthen materials, although they exhibit a brittle fracture with lack of plastic phase. T2 - 9th IMC - International Masonry Conference CY - Guimaraes, Portugal DA - 07.07.2014 KW - Earth block masonry KW - Pull-out tests KW - Anchor pins KW - Lime based hydraulic grout KW - Pull-out testing PY - 2014 SN - 978-972-8692-85-8 SP - Paper ID 1623, 1 EP - 12 AN - OPUS4-31139 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Miccoli, Lorenzo A1 - Fontana, Patrick A1 - Kreft, O. A1 - Pietruszka, B. A1 - Lukaszewska, A. A1 - Klinge, A. ED - De Schutter, G. ED - De Belie, N. ED - Janssens, A. ED - Van Den Bossche, N. T1 - Design of UHPC-AAC light-weight composite facade elements for refurbishment N2 - The aim of this study was to develop a lightweight composite façade element for refurbishment of existing façades. It was crucial to minimize the thermal bridges and to undercut the thermal requirement of the system existing façade new element. The awareness of the environmental impact of the building sector is increasing. In this context, ultra-high performance concrete (UHPC) materials are shown to be promising alternatives with advantages such as lower embodied energy and reduced environmental impact. Predictions suggest that UHPC composite elements for building envelopes could have other benefits such as an increased service life, optimized use of building area due to thinner elements and minimized maintenance due to the absence of reinforcement or use of non-corrosive reinforcing materials such as carbon fibers. In this framework, composite elements have been developed combining an autoclaved aerated concrete insulation layer with an external UHPC supporting layer. The results show that the lightweight composite element has a good performance in term of thermal transmittance and minimization of thermal bridges. T2 - XIV DBMC - 14th International Conference on Durability of Building Materials and Components CY - Gent, Belgium DA - 29.05.2017 KW - Composite panels KW - Ultra-high performance concrete KW - Autoclaved aerated concrete KW - Hygrothermal behaviour KW - Production technology PY - 2017 SN - 978-2-35158-159-9 VL - PRO 107 SP - 1 EP - 10 PB - RILEM Publications S.A.R.L. AN - OPUS4-40498 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, U. A1 - Miccoli, Lorenzo A1 - Fontana, Patrick T1 - Ein Kalkeinpressmörtel für die Instandsetzung von Lehmbauten T1 - A lime-based grouting material for the repair of earthen structures N2 - Die Instandsetzung von Lehmbauwerken ist keine einfache Aufgabe. Der Baustoff Lehm hat vergleichsweise schwache mechanische Eigenschaften. Er ist außerdem anfällig gegenüber eindringendem Wasser, wobei er sehr schnell seinen Zusammenhalt verlieren kann, wenn gewisse Feuchtegehalte überschritten werden. Instandsetzungskonzepte für Bauwerke aus solchen Materialien stellen deshalb eine Herausforderung dar. Historische Lehmbauwerke zeigen oft Schäden in Form von starker Rissbildung, die durch statische oder dynamische Lasten hervorgerufen sein kann. Häufig werden solche Risse wegen mangelnder Fachkenntnis und / oder fehlender Techniken nur ungenügend instandgesetzt. Die Rissinstandsetzung mit Einpressmörteln birgt insbesondere für Lehmbaustoffe eine Herausforderung und erfordert spezifische Anforderungen an den Einpressmörtel, wie z. B. niedriger Wassergehalt, gutes Wasserrückhaltevermögen, niedriges Schwindmaß, an das instandzusetzende Material angepasste Festigkeit und E-Modul sowie eine gute Haftung am Lehmuntergrund. Zusätzlich müssen Einpressmörtel eine ausreichende Fließfähigkeit aufweisen, um kleine Risse und Hohlräume ohne Entmischung zu füllen. Deshalb muss das rheologische Verhalten des Einpressmörtels gut untersucht und kontrolliert werden, um die gewünschte Wirkung zu erzielen. Die Rissinstandsetzung bei Lehmbauwerken erfolgt traditionell durch manuelles Stopfen mit einem Mörtel. Natürlich können auf diese Weise nur Risse mit einer großen Breite verfüllt werden. Ein weiterer Nachteil ist, dass Risse, die durch dickere Wände verlaufen, nicht vollständig mit den für das Stopfen verwendeten Werkzeugen erreicht werden können. Kalkgebundene Einpressmörtel für Lehmbaustoffe werden gewöhnlich für die Wiederbefestigung von Putzen und weniger aus statisch-konstruktiven Gründen eingesetzt. Aufgrund der Eigenschaften von Lehm, müssen Einpressmörtel auf Basis von hydraulischem Kalk nach EN 459-1 [4] wesentliche Anforderungen an eine Reihe von Eigenschaften erfüllen, die sich auf die Verträglichkeit, die Dauerhaftigkeit und insbesondere die Injektionsfähigkeit beziehen. Das Ziel der vorgestellten Untersuchungen war einen Einpressmörtel zu herzustellen, mit dem die strukturelle Kontinuität in Lehmmauerwerk oder anderen massiven Lehmwänden (Stampf- und Wellerlehm) durch Rissverpressung wiederhergestellt werden kann. Das Material bestand aus Kalkhydrat mit Zusätzen von Puzzolanen und Kalksteinfüller. N2 - The repair of earthen structures is not an easy task. Earth as a construction material has comparatively weak mechanical properties. It is also susceptible towards liquid water, were it can lose cohesion very quickly if certain moisture contents are exceeded. Repair concepts of structures built with such materials are therefore challenging. Historical earthen structures often exhibit damages in form of extensive cracking, which may have been caused by static or dynamic loads. Frequently these cracks are insufficiently or inappropriately repaired because of lack of knowledge and / or technology. In particular, the behaviour of crack repair by grouting poses a challenge in earthen materials and demands specific requirements for the grouting mortar, such as low water content, good water retention, low shrinkage. Grouting materials require additional specifications such as compatible strengths and Young’s modulus as well as good adhesion to the earthen substrates. In addition, grouts have to be sufficiently flowable to fill small cracks and voids without segregation or bleeding. Therefore, the rheological behaviour has to be well understood and controlled to gain the desired effects. The repair of cracks in earthen buildings is traditionally done by stuffing manually mortar into the gap. Naturally, this method is only usable for cracks with large widths. Another disadvantage is that cracks going through thicker walls cannot be completely reached by the tools used for stuffing the mortar into the crack. Lime based grouts for earthen materials were usually used for re-attachment of plasters but less for structural reasons. Due to the nature of earthen materials grouts based on formulated or hydraulic lime (according to the definition in EN 459-1 [4]) have to meet considerable demands on a variety of properties, which are related to compatibility, durability and in particular to the ability of being injected. The goal of this study was to create a grout, which can be used to re-establish structural continuity in cracked earthen masonry or other massive earth walls (rammed earth and cob) with the focus on grouting cracks. The grout material was based on hydrated lime (calcium hydroxide) with additions of pozzolana and lime stone filler. T2 - Lehm 2016 - 7. Internationale Fachtagung für Lehmbau - 7th International Conference on Building with Earth CY - Weimar, Germany DA - 12.11.2016 KW - Baustoffe KW - Einpressmörtel KW - Kalkhydrat KW - Lehmbau KW - Instandsetzung KW - Historische Bauwerke KW - Building materials KW - Grout mortar KW - Hydraulic lime KW - Earth construction KW - Repair KW - Historical buildings PY - 2016 SP - 1 EP - 10 PB - Eigenverlag Dachverband Lehm e. V. CY - Weimar AN - OPUS4-38992 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Miccoli, Lorenzo A1 - Fontana, Patrick A1 - Müller, U. ED - Van Balen, K. ED - Verstrynge, E. T1 - In-plane shear behaviour of earthen materials panels strengthened with polyester fabric strips N2 - An experimental investigation was carried out to study the in-plane shear behaviour of earthen material Panels strengthened with polyester fabric strips. Strengthened panels were developed to exploit the strength potential of earthen materials and to solve its lack of tensile strength, significantly improving not only strength but also ductility. Three earthen materials were considered: cob, earth block masonry (EBM) and rammed earth (RE). As first approach the strengthening configuration, based on different adhesive materials, was tested only for cob panels. As part of the study the results of a big testing campaign of unstrengthened Panels were considered. Seven strengthened panels were tested in diagonal compression/shear.A unique reinforcement orientation was used. The results of these tests are presented in this paper, and include the load-displacement behaviours, crack patterns, failure modes. The results showed that the reinforcement was the most effective in EBM panels, with increase in strength and ductility observed. In RE and cob panels the reinforcement did not likely contribute significantly to the shear resistance, due to a lack of embedment length of the strips. Instead, in EBM it was likely that the vertical reinforcement acted in tension to restrain shear induced dilation and to restrain sliding. T2 - 10th International Conference on Structural Analysis of Historical Constructions (SAHC 2016) CY - Leuven, Belgium DA - 13.09.2016 KW - Earthen materials KW - Strengthening KW - Diagonal compression test KW - Shear strength PY - 2016 SN - 978-1-138-02951-4 SP - 1099 EP - 1105 PB - Taylor & Francis Group CY - London AN - OPUS4-38993 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Miccoli, Lorenzo A1 - Oliveira, D. V. A1 - Silva, R. A. A1 - Drougkas, A. A1 - Fontana, Patrick T1 - Numerical modelling of rammed earth under different in-plane load conditions N2 - The paper presents a comparison between two different numerical modelling approaches aimed to simulate the in-plain behaviour of rammed earth walls, namely under axial, diagonal and cyclic shearcompression loading. In the first part of the study the mechanical characterisation of wallets tested under uniaxial compression and diagonal compression and walls tested under in-plane cyclic shear-compression loading is presented. The results were used to implement and validate the finite element simulations. The numerical modelling of the rammed earth samples tested is then discussed in the second part. A non-linear constitutive law based on the total strain rotating crack model (TSRCM) was employed as implemented in the DIANA® software. The aim of the numerical analyses presented here is to simulate the behaviour of rammed earth under different inplane loading conditions. For the wallets, tests under static loading both macro- and micro-modelling approaches were considered for the simulation of the experimental tests. For the walls subjected to cyclic loading only the micro-modelling approach was applied for the simulation of the experimental tests. The respective FEM model was calibrated with the experimental results. The rammed earth layers were represented by continuum elements, the contact surfaces between layers by interface elements. This approach allowed assessing the influence of the apparent weakness of the interfaces between layers on the shear behaviour of rammed earth. The goal of the numerical simulation of the cyclic tests was to establish the adequacy of common analytical methods (e. g. used for masonry) applied to the analysis of rammed earth. Rammed earth exhibits brittle characteristics similar to masonry materials and is used in geometrical typologies, such as walls, common in masonry construction. T2 - Lehm 2016 - 7th International Conference on Building with Earth CY - Weimar, Germany DA - 12.11.2016 KW - Building materials KW - FEM analysis KW - Rammed earth KW - Compression and shear testing KW - Cyclinc loading KW - Failure mode KW - Crack pattern PY - 2016 SP - 1 EP - 9 PB - Eigenverlag Dachverband Lehm e. V. CY - Weimar AN - OPUS4-38820 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Miccoli, Lorenzo A1 - Oliveira, D. V. A1 - Silva, R. A. A1 - Drougkas, A. A1 - Fontana, Patrick T1 - Numerische Modellierung von Stampflehm unter verschiedenen Lasteinflüssen N2 - Der Beitrag präsentiert einen Vergleich zwischen verschiedenen numerischen Modellierungsansätzen die dazu dienen sollen, das flächige Verhalten von Stampflehmwänden, genauer unter axialer, diagonaler und zyklischer Scherkraftbelastung zu simulieren. Im ersten Teil der Studie werden die mechanischen Eigenschaften der Wandscheiben, die unter einachsiger und diagonaler Druckbelastung getestet wurde und der Wände, die in flächigen, zyklischen Scherkraftbelastung getestet wurden, dargestellt. Die Ergebnisse werden verwendet, um die Finite Elemente Simulation anzuwenden und zu bewerten. Die numerische Modellierung der getesteten Stampflehmproben wird dann im zweiten Teil diskutiert. Ein nichtlineares Materialgesetz basierend auf dem Gesamtdehnungsrissmodell (total strain rotating crack model – TSRCM) wurde, wie durch die Software DIANA® verwendet, angesetzt. Ziel dieser hier präsentierten numerischen Analyse ist es, das Verhalten von Stampflehm unter verschiedenen Lasteinflüssen zu simulieren. Für die Wandscheiben wurden Versuche unter linearer Last, sowohl in Makro- als auch Mikromodellansätze für die Simulation der experimentellen Versuche gewählt. Für die Wände, welche zyklischer Belastung ausgesetzt waren, wurden nur die Mikromodellansätze für die Simulation der experimentellen Versuche gewählt. Das betreffende FEM Modell wurde mit den experimentellen Ergebnissen kalibriert. Die Stampflehmlagen wurden mit durchgehenden Elementen, die Kontaktflächen zwischen den Lagen mit Oberflächenelementen repräsentiert. Dieser Ansatz erlaubte die Bewertung des Einflusses der auftretenden Schwächung in den Oberflächen zwischen den Lagen auf das Scherverhalten des Stampflehms. Ziel der numerischen Simulation von zyklischen Versuchen war es, die Eignung allgemeiner Analysemethoden (z. B. für Mauerwerk) für die Analyse von Stampflehm einzuführen und anzuwenden. Stampflehm zeigt brüchige Eigenschaften vergleichbar zu Mauerwerksbaustoffen und wird in geometrischen Formen, wie Wänden, genutzt, die im Mauerwerk üblich sind. T2 - Lehm 2016 - 7. Internationale Fachtagung für Lehmbau CY - Weimar, Germany DA - 12.11.2016 KW - Baustoffe KW - FEM-Analyse KW - Stampflehm KW - Druck- und Schubprüfung KW - Zyklische Belastung KW - Versagensart KW - Rissmuster PY - 2016 SP - 1 EP - 9 PB - Eigenverlag Dachverband Lehm e. V. CY - Weimar AN - OPUS4-38821 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, U. A1 - Miccoli, Lorenzo A1 - Fontana, Patrick T1 - Ein Kalkeinpressmörtel für die Instandsetzung von Lehmbauten N2 - Die Instandsetzung von Lehmbauwerken ist keine einfache Aufgabe. Der Baustoff Lehm hat vergleichsweise schwache mechanische Eigenschaften. Er ist außerdem anfällig gegenüber eindringendem Wasser, wobei er sehr schnell seinen Zusammenhalt verlieren kann, wenn gewisse Feuchtegehalte überschritten werden. Instandsetzungskonzepte für Bauwerke aus solchen Materialien stellen deshalb eine Herausforderung dar. Historische Lehmbauwerke zeigen oft Schäden in Form von starker Rissbildung, die durch statische oder dynamische Lasten hervorgerufen sein kann. Häufig werden solche Risse wegen mangelnder Fachkenntnis und / oder fehlender Techniken nur ungenügend instandgesetzt. Die Rissinstandsetzung mit Einpressmörteln birgt insbesondere für Lehmbaustoffe eine Herausforderung und erfordert spezifische Anforderungen an den Einpressmörtel, wie z. B. niedriger Wassergehalt, gutes Wasserrückhaltevermögen, niedriges Schwindmaß, an das instandzusetzende Material angepasste Festigkeit und E-Modul sowie eine gute Haftung am Lehmuntergrund. Zusätzlich müssen Einpressmörtel eine ausreichende Fließfähigkeit aufweisen, um kleine Risse und Hohlräume ohne Entmischung zu füllen. Deshalb muss das rheologische Verhalten des Einpressmörtels gut untersucht und kontrolliert werden, um die gewünschte Wirkung zu erzielen. Die Rissinstandsetzung bei Lehmbauwerken erfolgt traditionell durch manuelles Stopfen mit einem Mörtel. Natürlich können auf diese Weise nur Risse mit einer großen Breite verfüllt werden. Ein weiterer Nachteil ist, dass Risse, die durch dickere Wände verlaufen, nicht vollständig mit den für das Stopfen verwendeten Werkzeugen erreicht werden können. Kalkgebundene Einpressmörtel für Lehmbaustoffe werden gewöhnlich für die Wiederbefestigung von Putzen und weniger aus statisch-konstruktiven Gründen eingesetzt Aufgrund der Eigenschaften von Lehm, müssen Einpressmörtel auf Basis von hydraulischem Kalk nach EN 459-1 wesentliche Anforderungen an eine Reihe von Eigenschaften erfüllen, die sich auf die Verträglichkeit, die Dauerhaftigkeit und insbesondere die Injektionsfähigkeit beziehen. Das Ziel der vorgestellten Untersuchungen war einen Einpressmörtel zu herzustellen, mit dem die strukturelle Kontinuität in Lehmmauerwerk oder anderen massiven Lehmwänden (Stampf- und Wellerlehm) durch Rissverpressung wiederhergestellt werden kann. Das Material bestand aus Kalkhydrat mit Zusätzen von Puzzolanen und Kalksteinfüller. T2 - Lehm 2016 - 7. Internationale Fachtagung für Lehmbau CY - Weimar, Germany DA - 12.11.2016 KW - Baustoffe KW - Einpressmörtel KW - Kalkhydrat KW - Lehmbau KW - Instandsetzung KW - Historische Bauwerke PY - 2016 SP - 1 EP - 10 PB - Eigenverlag Dachverband Lehm e. V. CY - Weimar AN - OPUS4-38824 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, U. A1 - Miccoli, Lorenzo A1 - Fontana, Patrick T1 - A lime-based grouting material for the repair of earthen structures N2 - The repair of earthen structures is not an easy task. Earth as a construction material has comparatively weak mechanical properties. It is also susceptible towards liquid water, were it can lose cohesion very quickly if certain moisture contents are exceeded. Repair concepts of structures built with such materials are therefore challenging. Historical earthen structures often exhibit damages in form of extensive cracking, which may have been caused by static or dynamic loads. Frequently these cracks are insufficiently or inappropriately repaired because of lack of knowledge and / or technology. In particular, the behaviour of crack repair by grouting poses a challenge in earthen materials and demands specific requirements for the grouting mortar, such as low water content, good water retention, low shrinkage. Grouting materials require additional specifications such as compatible strengths and Young’s modulus as well as good adhesion to the earthen substrates. In addition, grouts have to be sufficiently flowable to fill small cracks and voids without segregation or bleeding. Therefore, the rheological behaviour has to be well understood and controlled to gain the desired effects. The repair of cracks in earthen buildings is traditionally done by stuffing manually mortar into the gap. Naturally, this method is only usable for cracks with large widths. Another disadvantage is that cracks going through thicker walls cannot be completely reached by the tools used for stuffing the mortar into the crack. Lime based grouts for earthen materials were usually used for re-attachment of plasters but less for structural reasons. Due to the nature of earthen materials grouts based on formulated or hydraulic lime (according to the definition in EN 459-1) have to meet considerable demands on a variety of properties, which are related to compatibility, durability and in particular to the ability of being injected. The goal of this study was to create a grout, which can be used to re-establish structural continuity in cracked earthen masonry or other massive earth walls (rammed earth and cob) with the focus on grouting cracks. The grout material was based on hydrated lime (calcium hydroxide) with additions of pozzolana and lime stone filler. T2 - Lehm 2016 - 7th International Conference on Building with Earth CY - Weimar, Germany DA - 12.11.2016 KW - Building Materials KW - Grout mortar KW - Hydraulic lime KW - Earth construction KW - Repair KW - Historical buildings PY - 2016 SP - 1 EP - 8 PB - Eigenverlag Dachverband Lehm e. V. CY - Weimar AN - OPUS4-38825 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Miccoli, Lorenzo A1 - Fontana, Patrick A1 - Silva, N. A1 - Kocadag, R. A1 - Cederqvist, Ch. A1 - Krefft, O. A1 - Qvaesching, D. T1 - UHPC-AAC/CLC composite panels with self-cleaning properties. Materials and production technology N2 - The aim of this study is to show the development of a façade composite panel combining either an autoclaved aerated concrete or a cellular lightweight concrete insulation layer with a box-type external ultra-high performance concrete (UHPC) supporting layer. The paper presents the materials characteristics of the different components and the production technology of the panel. The efficiency of surface modifications of the materials forming the external shell of the panel is reported. The activation of self-cleaning properties is described. The test results showed that the most efficient way to use the water-repellent agent is its application on the substrate before the concrete cast. Concerning the production technology, the preliminary studies showed more advantages of a twostep manufacturing procedure of the UHPC boxes than a one-step procedure. T2 - Smart Facades Materials Conference CY - Wels, Austria DA - 24.02.2016 KW - facade composite panels KW - ultra-high performance concrete (UHPC) KW - autoclaved aerated concrete (AAC) KW - cellular lightweight concrete (CLC) KW - self-cleaning properties PY - 2016 SP - 1 EP - 14 PB - OÖ Energiesparverband CY - Wels, Austria AN - OPUS4-37185 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Miccoli, Lorenzo A1 - Fontana, Patrick A1 - Ziegert, C. A1 - Müller, P. ED - Modena, C. ED - da Porto, F. ED - Valluzzi, M. R. T1 - Calibration of partial safety factors for earth block masonry under compression loading N2 - The goal of the present study is to assess the feasibility to develop a first reliable database of materials parameters for Earth Block Masonry (EBM). The database is crucial when defining the materials safety factors. In the first part an experimental campaign of compressive tests were carried out on two types of earth block and two types of earth mortar. The results showed that the mean variation of the compressive strength was remarkably less than expected. This low variation is related to a production with high quality standards of the materials employed. In the second part a partial safety factor for EBM under uniaxial compression was determined through the reliability method. The results proved the reliability of a common calculation method for EBM based on partial safety factors following the current standards. T2 - IB2MAC 2016 - 16th International Brick and Block Masonry Conference CY - Padua, Italy DA - 26.06.2016 KW - earth block masonry KW - partial safety factors KW - uniaxial compression test PY - 2016 SN - 978-1-138-02999-6 SP - 857 EP - 864 PB - CRC Press Taylor & Francis Group CY - London, UK AN - OPUS4-37145 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ferraioli, M. A1 - Abruzzese, D. A1 - Miccoli, Lorenzo A1 - Mandara, A. ED - Galea, P. ED - Borg, R. P. ED - Farrugia, D. ED - Agius, M. R. ED - D'Amico, S. ED - Torpiano, A. ED - Bonello, M. T1 - Dynamic identification and seismic safety of two masonry towers N2 - The recent experience of Italian seismic events provided wide observational information about typical behaviour, damage patterns and intrinsic vulnerability of monumental buildings. Evidence indicates that historical constructions are by far the most vulnerable from the seismic point of view. As a consequence, they demand for the definition of urgent strategies for the protection of cultural heritage from seismic hazard. The main goal of an in-depth knowledge of the structure should help to avoid inadequate, unsuitable or dangerous rehabilitation operations, as well as to select non-invasive and reversible techniques for the best exploitation of material and technology features. The definition of reliable models and methods for seismic risk assessment of historical constructions is today a very important topic. Typical problems of masonry structures concern aspects like inherent structural lacks, material degradation, geotechnical problems, buckling behaviour of slender elements and dynamic loading vulnerability. Modelling the mechanical behaviour of masonry may play an important role, due to both inherent material complexity and great scatter in mechanical properties. Effective procedures for the identification of the structural parameters from static and dynamic testing are thus required. In particular, dynamic measurements may be very useful for the identification of mechanical properties and soil restraints and, consequently, for the calibration of advanced numerical finite element models. The paper addresses two case studies of structural monitoring and seismic assessment of medieval masonry towers in Italy: the bell tower of Aversa and the bell tower of Capua. These monuments, placed in the Campania region, were monitored by means of full-scale environmental vibration testing. Measured responses are then used for modal identification with a typical finite element model updating technique based on vibration test results. Parameters optimization is carried out on the basis of a criterion which minimises a weighted error on modal properties. A satisfactory improvement in the determination of modal parameters is thus obtained, resulting in a close agreement between the modal properties observed in dynamic tests and those calculated from numerical model. Seismic assessment is finally performed based on nonlinear static analysis of the tower under multimodal distributions of lateral loads. Results from nonlinear analysis indicate the potential collapse mechanisms and evidence dangerous structural weakness which may play a role in the seismic vulnerability of the towers. T2 - Georisk in the Mediterrean and their mitigation CY - Valletta, Malta DA - 20.07.2015 KW - masonry towers KW - ambient vibration tests KW - dynamic characterisation KW - seismic assessment PY - 2016 SN - 978-88-98161-20-1 SP - 250 EP - 251 PB - Mistral Service AN - OPUS4-37204 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Miccoli, Lorenzo A1 - Müller, U. A1 - Fontana, Patrick ED - Mazzolani, F. M. ED - Lamas, A. ED - Calado, L. ED - Proenca, J. M. ED - Faggiano, B. T1 - Strengthening of rammed earth structural elements. Mechanical behaviour under shear and cyclic loading N2 - An experimental investigation was carried out to study the in-plane shear behaviour of rammed earth structural elements strengthened with polyester fabric strips. The original idea for the retrofitting with polyester fabric strips was to introduce a vertical element for walls in order to take up horizontal loads resulting in a shear response of the building element. It has to be considered that vertical slits into the walls for fixing the strips are points of weakness and have to be mitigated by the adhesive. In this case a base coat mortar was employed. Strengthened elements were tested to exploit the strength potential of earthen materials and to solve its lack of tensile strength, significantly improving not only strength but also ductility. As part of the study results of a testing campaign of unstrengthened structural elements were considered. Strengthened elements were tested in diagonal compression/shear and cyclic shear-compression. A unique reinforcement orientation was used. The results of these tests are presented in this paper and include the load-displacement behaviours, crack patterns, failure modes. The results showed that the reinforcement was the most effective under cyclic shear-compression tests, with increase in load and displacement capacity observed. Under diagonal compression the reinforcement did not likely contribute significantly to the shear resistance, due to a lack of embedment length of the strips. T2 - 3rd International Conference on Protection of Historical Constructions (PROHITECH 2017) CY - Lisbon, Portugal DA - 12.07.2017 KW - Rammed earth KW - Diagonal compression tests KW - Shear-compression tests KW - Strengthening KW - Polyester fabric strips PY - 2017 SN - 978-989-8481-58-0 SP - 157 EP - 158 PB - IST-Press AN - OPUS4-41263 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ferraioli, M. A1 - Miccoli, Lorenzo A1 - Abruzzese, D. ED - Mazzolani, F. M. ED - Lamas, A. ED - Calado, L. ED - Proenca, J. M. ED - Faggiano, B. T1 - Seismic risk assessment of the Santa Maria a Vico bell tower. Ambient vibration measurements and numerical model tuning N2 - The paper investigates the dynamic characterisation along with the numerical model tuning and the seismic risk assessment of a monumental masonry tower in Italy namely the Santa Maria a Vico bell tower. Full-scale ambient vibration tests were performed under the impact of environmental loads. The technique of modal extraction in the frequency domain was applied. In-situ investigation survey was used in calibrating the refined 3D finite element model. The FEM tuning was carried out by varying the mechanical parameters and accounting for the restraint offered by the neighbouring buildings and the role of soil–structure interaction. The paper shows that the modal identification is a reliable technique that can be used in-situ for assessing the dynamic behaviour of monumental buildings. The tuned FEM model of the tower was usefully employed to determine the theoretical fundamental frequencies, which accurately fit the experiment data. Finally, the seismic performance of the bell tower was assessed using a non-linear static procedure based on the multi-modal pushover analysis and the capacity spectrum method. The results confirm that seismic events of moderate intensity can produce heavy damage to the masonry tower presented in this study. T2 - 3rd International Conference on Protection of Historical Constructions (PROHITECH 2017) CY - Lisbon, Portugal DA - 12.07.2017 KW - Masonry tower KW - Ambient vibration tests KW - Dynamic characterisation KW - Seismic assessment PY - 2017 SN - 978-989-8481-58-0 SP - 159 EP - 160 PB - IST-Press AN - OPUS4-41279 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Miccoli, Lorenzo A1 - Perrone, C. A1 - Müller, Urs A1 - Gardei, André A1 - Ziegert, C. T1 - Comparison of mechanical behavior of different earth masonry typologies in cultural heritage N2 - The paper has been developed in the framework of a larger EC‐research program called NIKER, in which BAM and other seventeen research partners from the Mediterrean area are jointly involved. It aims to develop and validate innovative materials and technologies for the systemic improvement of the seismic behavior of Cultural Heritage assets. The death tolls brought about by recent catastrophes in developing countries where many inhabitants lived in earthen dwellings (Gujarat, India 2001, Bam, Iran 2003 and Concepción, Chile 2010 Earthquakes, Tamil Nadu 2004 Tsunami) have brought about research studies aimed at improving earth construction in terms of strength, seismic resistance and speed of construction. In comparison to the recent advances in research on stone and brick masonry, knowledge on the material properties and failure mechanisms of earthen Building construction is limited and scattered. The research presented here by aims making a comparison of mechanical behaviour between different earth masonry material typologies, consisting of earth block masonry, rammed earth and cob. T2 - WCCE-ECCE-TCCE Joint conference 2 - Seismic protection of cultural heritage CY - Antalya, Turkey DA - 31.10.2011 KW - Earth masonry KW - Material test KW - Cultural heritage KW - Seismic resistance PY - 2011 SN - 978-605-01-0188-1 SP - 25 EP - 36 AN - OPUS4-24836 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ferraioli, M. A1 - Mandara, A. A1 - Abruzzese, D. A1 - Miccoli, Lorenzo T1 - Dynamic identification and seismic safety of masonry bell towers N2 - The paper addresses two case studies of structural monitoring and seismic assessment of medieval masonry Towers in Italy: the bell tower of Aversa and the bell tower of Capua. These monuments in the Campania region were monitored by means of full-scale environmental vibration testing. Measured responses were then used for modal identification. The procedure is based on a typical finite element model updating technique based on vibration test results. Parameters optimization is carried out by minimizing a weighted error criterion relative to the building’s modal properties. A satisfactory improvement on modal parameters is thus obtained, resulting in a close Agreement between the modal properties observed in dynamic tests and those calculated from numerical model. Seismic assessment is carried out with nonlinear static analysis of the tower under multimodal distributions of lateral loads. Nonlinear analysis indicates the potential collapse mechanisms and evidences dangerous structural weakness which may play a role in the seismic vulnerability of the towers. T2 - 14th Conference of seismic engineering ANIDIS CY - Bari, Italy DA - 18.09.2011 KW - Masonry towers KW - Structural identification KW - Model updating PY - 2011 SN - 978-88-7522-040-2 IS - Abschnitt E SP - 1 EP - 10 AN - OPUS4-24839 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ferraioli, M. A1 - Abruzzese, D. A1 - Miccoli, Lorenzo A1 - Di Lauro, G. T1 - Torsional seismic response of an asymmetric-plan hospital buidling N2 - The inelastic torsional response of an asymmetric-plan hospital building is studied. The response of the structure in the time domain as recorded by highly sensitive sensor network, integrated by a data acquisition system. The identification was performed using techniques of modal extraction in the frequency domain (frequency Domain decomposition). A calibration process was applied in order to identify a reliable structural model to be used for the seismic vulnerability assessment of the hospital building. In particular, a nonlinear static procedure accounting for mass distribution, higher modes contribution and mode-shapes correlation was proposed for the estimation of the seismic response of irregular buildings. Finally, the influence of lateral force distribution, node control during pushover and accidental eccentricity is investigated. T2 - 14th Conference of seismic engineering ANIDIS CY - Bari, Italy DA - 18.09.2011 KW - Seismic response KW - Irregular buildings KW - Inelastic torsion PY - 2011 SN - 978-88-7522-040-2 IS - Abschnitt D SP - 1 EP - 10 AN - OPUS4-24840 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Miccoli, Lorenzo A1 - Perrone, C. A1 - Müller, Urs A1 - Gardei, André A1 - Ziegert, C. ED - Drochytka, R. ED - Bohus, S. T1 - Structural performances of earthen building materials. A comparison between different typologies N2 - Traditional construction techniques utilizing earthen materials are often seen as inferior compared to modern ways of building. Structural earthen elements are perceived as vulnerable towards environmental influences (moisture, frost) and in particular towards the load scenarios during earthquakes. In comparison to the recent advances in research on stone and brick masonry, knowledge on the structural performance of earthen building construction is limited and scattered. Consequently the confidence in the performance of these earthen buildings constructed in the traditional techniques during earthquakes is fairly low. The research presented here aims to make a comparison of mechanical behavior between different earth masonry material typologies, consisting of earth block masonry, rammed earth and cob. The paper has been developed in the framework of a larger research program called NIKER. BAM and other seventeen research partners from the Mediterrean area are jointly involved to develop and validate innovative materials and technologies for the systemic improvement of the seismic behavior of Cultural Heritage assets T2 - 2nd WTA - Internaitonal PhD Symposium - Building materials and buidling technology to preserve the built heritage CY - Brno, Czech Republic DA - 06.10.2011 KW - Earth masonry KW - Material test KW - Mechanical behavior KW - Cultural heritage PY - 2011 SN - 978-3-937066-21-9 SN - 0947-6830 N1 - Serientitel: WTA-Schriftenreihe – Series title: WTA-Schriftenreihe VL - 2 / Part 2 IS - 36 SP - 86 EP - 94 PB - WTA Publications AN - OPUS4-24928 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Richter, Matthias A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Juritsch, Elevtheria A1 - Klinge, A. A1 - Roswag, E. A1 - Fontana, Patrick A1 - Miccoli, Lorenzo T1 - Indoor air emission tests of natural materials N2 - Emissions of building materials might have negative impact on human health and well-being. In the EU-funded research project H-House more than 30 natural materials (earthen dry boards and plasters, bio-based insulation materials made of wood, flax, reed, straw, etc.) used for renovation and refurbishment were tested regarding emissions of VOC, formaldehyde and radon. Different to ordinary emission tests on single materials this study focuses on the emissions from complete wall assemblies. Therefore, specially designed test chambers were used allowing the compounds to release only from the surface of the material facing indoors. The testing parameters were chosen in order to simulate model room conditions. The emission results were finally evaluated using the AgBB evaluation scheme, a procedure currently applied for the approval of flooring materials in Germany. T2 - 1st ICBBM - International conference on bio-based building materials CY - Clermont-Ferrand, France DA - 22.06.2015 KW - Emission testing KW - Natural materials KW - VOC KW - Formaldehyde KW - Radon PY - 2015 SN - 978-2-35158-154-4 SP - 641 EP - 643 AN - OPUS4-33609 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Miccoli, Lorenzo ED - Priebe, Nsesheye Susan ED - Schmidt, Wolfram T1 - Earthen building materials: Hydraulic lime based grout for retrofitting and CEBs stabilised with geopolymer binders N2 - From the last decades the earth construction has a growing interest due to the high sustainability (low C02 emissions), thermal and acoustic performance, fire resistance and cost of the raw material (soil). In fact, earth construction can constitute a feasible solution for a more sustainable construction industry in developed countries. Nowadays the research areas on earthen construction focus from one side on the improvement of the materials for new buildings, on the other side on the Conservation of existing architectural heritage. Historical earthen buildings are often damaged by static or dynamic loads in form of extensive cracking. All too often these cracks are insufficiently or inappropriately repaired, if at all, because of lack of knowledge and/or technology. In particular, the behaviour of crack repair by grouting poses a challenge in earthen materials and demands specific requirements for the grouting mortar, such as low water content, good water retention, low shrinkage, etc. Cracks in earthen construction can be repaired by grouting to re-establish structural continuity, and can also be used to consolidate voids and gaps, or as a complement to other strengthening techniques such as the introduction of tie-rods. In the framework of earthen materials for new constructions, the major drawback is that traditional earthen materials are typically considered as non-standard. The great variability and heterogeneity of the properties of the available soils, the lack of quality control in the manufacturing of the earthen materials and in the construction process can be pointed out as the main reasons behind this Situation. Furthermore, only few countries issued Standards and recommendations supporting earth construction, discouraging the design of earth construction by the technical community in countries where these documents are absent. T2 - KEYS 2015 - 1st Symposium Knowledge Exchange for Young Scientists CY - Dar es Salaam, Tanzania DA - 09.06.2015 KW - Earthen building materials KW - Hydraulic lime based grout KW - Compressed earth blocks KW - Geopolymer binders PY - 2015 SN - 978-3-9817149-3-7 N1 - Geburtsname von Priebe, Nsesheye Susan: Msinjili, N. S. - Birth name of Priebe, Nsesheye Susan: Msinjili, N. S. SP - 141 EP - 144 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-33606 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Miccoli, Lorenzo A1 - Müller, U. A1 - Silva, B. A1 - Da Porto, F. A1 - Hracov, S. A1 - Pospisil, S. A1 - Adami, C.-E. A1 - Vintzileou, E. A1 - Vasconcelos, G. A1 - Poletti, E. ED - Jasienko, J. T1 - Overview of different strengthening techniques applied on walls used in historical structures N2 - Different types of vertical elements, such as masonry, massive walls and timber frame elements, exhibit a different response exposed to the same loading scenario, in particular when it concerns dynamic loading. It is therefore paramount to investigate the principal response of different types of construction with different materials under a variety of loading scenarios. From there, the design of strengthening techniques against earthquakes can be performed. This paper presents the results from experiments, where various retrofitting techniques were tested. The goals were to define and improve laboratory procedures for evaluating the intervention technologies and specifications for laboratory specimens. From this base tests to characterise the experimental behaviour of original and strengthened masonry walls were performed, in order to obtain information on the system performance and the main constitutive laws relevant for modelling. The test campaigns were focused on static tests as well as cyclic tests of unreinforced and reinforced vertical building elements. The study is part of our work in the framework of the ongoing project NIKER funded by the European Commission dealing with improving immovable Cultural Heritage assets against the risk of earthquakes. T2 - SAHC 2012 - 8th International conference on structural analysis of historical constructions CY - Wroclaw, Poland DA - 15.10.2012 KW - Stone masonry KW - Brick masonry KW - Earthen materials KW - Half timbered walls KW - Grouting PY - 2012 SN - 978-83-7125-216-7 SN - 0860-2395 VL - 3 SP - 2870 EP - 2878 PB - DWE CY - Wroclaw, Poland AN - OPUS4-27275 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Vintzileou, E. A1 - Valluzzi, M.R. A1 - Mazzon, N. A1 - Posipsil, S. A1 - Miccoli, Lorenzo ED - Jasienko, J. T1 - Systemic improvement of overall seismic response N2 - Subassemblies and building models at reduced scale are tested on shaking table facilities. This experimental program is part of the project NIKER and constitutes the Work Package 7 (WP7): “Systemic improvement of overall seismic response”. The purpose of this WP is to define global intervention strategies through shaking table tests on both substructures and entire structures before and after intervention in order to check the performance of single elements and to characterize the seismic behaviour of whole buildings. The obtained results will also allow data for FE and analytical modelling to be obtained for both single elements and whole structures. The design and the testing protocol of both subassemblies and building models were based on the results obtained from the experimental campaigns carried out on individual vertical members (quasi-static tests), on horizontal elements (e.g. floors and roofs) and on connections between bearing elements, all these performed within the same project. The experiments summarized in this paper proved the efficiency of the investigated intervention techniques and provided fundamental data to calibrate analytical models, developed within the same project, in order to describe the seismic behaviour of historic structures both in unstrengthened and strengthened conditions. This paper provides a brief overview of the whole dynamic experimental campaign and introduces some key experimental results. T2 - SAHC 2012 - 8th International conference on structural analysis of historical constructions CY - Wroclaw, Poland DA - 15.10.2012 KW - Historic structures KW - Shaking table tests KW - Subassemblies KW - Scaled models PY - 2012 SN - 978-83-7125-216-7 SN - 0860-2395 VL - 3 SP - 2897 EP - 2905 PB - DWE CY - Wroclaw, Poland AN - OPUS4-27274 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Paganoni, S. A1 - D'Ayala, D. A1 - Miccoli, Lorenzo A1 - Hracov, S. A1 - Urushadze, S. A1 - Wünsche, M. A1 - Adami, C.-E. A1 - Vintzileou, E. A1 - Moreira, S. A1 - Oliveira, D.V. A1 - James, P. A1 - Cóias e Silva, V. ED - Jasienko, J. T1 - Connections and dissipative systems with early warning N2 - The global response of historic buildings is determined by the behaviour of the single structural elements as well as by their mutual connections. Consequently, in the last decades a number of technical solutions for the improvement of structural connections have been developed in response to the increasing demand in the field of the seismic protection of heritage assets. At the same time, the experimental assessment of structural strengthening techniques is a well established practice both in the scientific community and among commercial producers. It is therefore surprising how testing of connections is rarely performed and very few codes of practice deal with it. Additionally, the few existing experimental procedures for testing connections are neither standardised nor easily accessible to end users. Within the work frame of the EU-funded NIKER project, Work Package 6 aims to address such technical gap through the development of procedures specific to the strengthening of structural connections of historic buildings. T2 - SAHC 2012 - 8th International conference on structural analysis of historical constructions CY - Wroclaw, Poland DA - 15.10.2012 KW - Seismic strengthening KW - Structural connections KW - Heritage buildings PY - 2012 SN - 978-83-7125-216-7 SN - 0860-2395 VL - 3 SP - 2888 EP - 2896 PB - DWE CY - Wroclaw, Poland AN - OPUS4-27276 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, Urs A1 - Miccoli, Lorenzo A1 - Malaga, K. T1 - A new grouting material for the repair of cracks in earthen structures N2 - Traditional earthen structures of cultural value are often damaged by static or dynamic loads. This is usually manifested by the appearance of cracks. All too often these cracks are insufficiently or inappropriately repaired if at all because of lack of knowledge and/or technology. In particular, the behavior of crack repair by grouting poses a challenge in earthen materials and demands specific requirements for the grouting mortar, such as low water content, good water retention, low shrinkage, etc. If dynamic loads, e.g. induced by earthquakes, are expected, the grouting material requires additional specifications such as a compatible strength and modulus of elasticity as well as good adhesion to the earthen materials. The study presents results from the development of a grouting material based on hydraulic lime mortar suitable for the repair of cracks in a variety of earthen building techniques. The goal was to develop a material also compatible with earthen structures exposed to dynamic load. The grouting mortar was designed to be adaptable in strength properties and at the same time to have sufficient robustness for the use on the construction site. First results show a satisfactory performance of the grout concerning fresh and hardened mortar properties as well as injectability. The study is part of our work in the framework of the ongoing project NIKER, funded by the European Commission dealing with improving imovable Cultural Heritage assets against the risk of earthquakes. T2 - Terra 2012 - 11th International conference on the study and conservation of earthen architecture heritage CY - Lima, Peru DA - 22.04.2012 KW - Cracks KW - Grouting KW - Lime mortar KW - Earthen Structures KW - Cracks repair PY - 2012 SN - 978-9972-2885-5-5 IS - Theme 6 - t6_059 SP - 1 EP - 10 AN - OPUS4-30381 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Miccoli, Lorenzo A1 - Müller, U. ED - Jasienko, J. T1 - Characterisation of earthen elements. A comparison between earth block masonry, rammed earth and cob T2 - SAHC 2012 - 8th International conference on structural analysis of historical constructions CY - Wroclaw, Poland DA - 15.10.2012 KW - Earthen materials KW - Compression test KW - Diagonal compression test KW - Initial shear strength test PY - 2012 SN - 978-83-7125-216-7 SN - 0860-2395 VL - 1 SP - 841 EP - 849 PB - DWE CY - Wroclaw, Poland AN - OPUS4-27277 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, U. A1 - Miccoli, Lorenzo A1 - Perrone, C. A1 - Ziegert, C. T1 - Vergleich und Modellierung der mechanischen Eigenschaften von Bauteilen aus Lehmsteinmauerwerk, Wellerlehm und Stampflehm N2 - Im Rahmen des EU-Projekts NIKER (www.niker.eu) wurden die mechanischen Eigenschaften von Bauteilen aus Lehmsteinmauerwerk, Wellerlehm und Stampflehm bestimmt. Ziel war es grundlegende Daten zum Festigkeits- und Verformungsverhalten von Lehmbauteilen zu erhalten. Die Daten wurden als Eingangsgrößen zur Modellierung des Bauteilverhaltens verwendet. Die Ergebnisse zeigten, dass unter Druckbeanspruchung Lehmsteinmauerwerk und Stampflehm ein ähnliches Verformungsverhalten aufweisen. Dagegen zeigte Wellerlehm zwar deutlich niedrigere Druckfestigkeiten aber das Nachbruchverhalten war im Vergleich zu den beiden anderen Bauweisen wesentlich deutlicher ausgeprägt. Erste Ergebnisse zur Makromodellierung des Festigkeits- und Verformungsverhaltens sowohl im elastischen als auch plastischen Bereich zeigen eine gute Übereinstimmung mit den experimentell ermittelten Daten. Die Modellierung auch von komplizierteren Lehmbauteilformen unter statischer Last scheint somit in absehbarer Zeit möglich. T2 - Lehm 2012 - 6. Internationale Fachtagung für Lehmbau CY - Weimar, Germany DA - 05.10.2012 KW - Stampflehm KW - Lehmstein KW - Mauerwerk KW - Wellerlehm KW - Mechanische Eigenschaften PY - 2012 SN - 978-3-00-039649-6 IS - Session C SP - 320 EP - 331 AN - OPUS4-26936 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ferraioli, M. A1 - Mandara, A. A1 - Abruzzese, D. A1 - Miccoli, Lorenzo ED - Ferrari, A. T1 - Seismic assessment of two masonry medieval bell towers N2 - The paper shows a methodology that can be applied to assess the seismic vulnerabilty of regular and tall masonry towers. T2 - 5th International congress on science and technology for the safeguard of cultural heritage in the Mediterranean basin CY - Istanbul, Turkey DA - 22.11.2011 KW - Masonry towers KW - Environmental vibration tests KW - Dynamic identification KW - Seismic assessment PY - 2012 SN - 978-88-905639-8-0 VL - II SP - 220 EP - 226 PB - CNR AN - OPUS4-26208 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Miccoli, Lorenzo A1 - Pospísil, S. A1 - Müller, U. A1 - Hracov, S. T1 - Verhalten von Lehmstein- und Stampflehmwänden unter dynamischer Belastung und Effizienz von Bewehrungsmaßnahmen N2 - Lehmbauten repräsentieren einen bedeutenden Teil des kulturellen Erbes. Sie erfordern einen hohen Erhaltungsaufwand und wenngleich die Beschädigung sowie der Einsturz solcher Wohngebäude zum Verlust von Menschenleben führen, sind Erdbeben ebenso verheerend für das gebaute kulturelle Erbe in diesen Regionen. In der Tat wird es häufig übersehen, dass ein bedeutender Teil der Weltkulturerbestätten, die gefährdet sind, aus Lehm gebaut sind. T2 - Lehm 2012 - 6. Internationale Fachtagung für Lehmbau CY - Weimar, Germany DA - 05.10.2012 KW - Earth blocks KW - Rammed earth KW - Static loads KW - Dynamic loads KW - Cyclic tests PY - 2012 SN - 978-3-00-039649-6 IS - Session C SP - 122 EP - 133 AN - OPUS4-26935 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Miccoli, Lorenzo A1 - Müller, Urs A1 - Perrone, C. A1 - Ziegert, C. T1 - Earth block masonry, rammed earth and cob: earthen components from different construction techniques and their structural performance N2 - Both in developed and developing countries, modern building materials tend to be preferred to traditional earthen construction. Reasons include low durability, inadequate performance under seismic loading and, in developing countries, a wish to replace what is perceived as 'poor' with what is perceived as 'rich'. In an age when building permissions and construction standards are a must, particularly in seismic areas, even when an owner is willing to build in earth, construction approval needs to be granted: we rely on values and standards to build, but the necessary data on material properties and structural performance of earthen building techniques is scarce if compared to the abundance of data for other materials (clay brick masonry, concrete, steel) available to the engineer. At the same time, traditional builders' skills, knowledge and confidence in earthen building techniques are decreasing if not disappearing. A wallette testing campaign was thus carried out with the aim of filling this knowledge gap. Prior to the wallette campaign, material properties, including composition and physical-mechanical parameters, were determined. Compression and diagonal compression (shear) tests were then performed, and a basic analysis of the mechanical behaviour of structural elements built in cob is provided in relation to earth block (adobe) masonry and rammed earth elements. Cob, shown to have low compressive resistance, has a relatively ductile post-peak behaviour if compared to earth block masonry specimens which, as expected, show a marked brittle behaviour. In terms of shear strength, cob performs relatively well in view of its low compressive strength. The study is part of our work within the framework of the ongoing project NIKER funded by the European Commission dealing with improving the structural performance of Cultural Heritage assets in order to limit earthquake hazards. T2 - Terra 2012 - 11th International conference on the study and conservation of earthen architecture heritage CY - Lima, Peru DA - 22.04.2012 KW - Earth block KW - Rammed earth KW - Cob KW - Mechanical properties KW - Earthen architecture KW - Earth block masonry PY - 2012 SN - 978-9972-2885-5-5 IS - Theme 6 - t6_066 SP - 1 EP - 10 AN - OPUS4-30380 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -