TY - CONF A1 - Köppe, Tabea A1 - Bartholmai, Matthias A1 - Daum, Werner ED - Ognjanovic, M. ED - Stankovic, M. ED - Ristic, M. T1 - Introduction in the system of the split Hopkinson pressure bar and validation of the method T2 - DAS-29 - 29th Danubia-Adria-symposium on advances in experimental mechanics (Proceedings) N2 - The Split Hopkinson Pressure Bar (SHPB) or Kolsky Bar is known as a method for analysing mechanical properties of a material under dynamic load. Referring to the name it is a splitted Hopkinson Pressure Bar. The Hopkinson Bar is related to its inventor Bertram Hopkinson (1914). He used it to analyze stone samples under dynamic load. Later his construction was improved by Davies (1948) [1] and Kolsky (1949) [2], who had the idea to split the bar and put a sample in between. The technique is used to measure a lot of different mechanical properties of a material e.g. the dynamic Young’s modulus, deformation behaviour or to chart the dynamic stress-strain diagram. Further applications are the measurement of the elastic wave and the analysis of the propagation of the wave [2]. In the last years there was still an interest in measuring dynamic properties with a SHPB. Nevertheless no comprehensive validation of the system exists. Another problem is that the stress and the strain in the sample are only calculated with simplified estimations. The aim of this paper is to give a first impression of important points validating the system. On account of different setups of the SHPB a validation of the used system is necessary. Hence it is important to look at the theory. Further in this paper the measurement results will be shown in a strain over time diagram. T2 - DAS-29 - 29th Danubia-Adria-symposium on advances in experimental mechanics CY - Belgrade, Serbia DA - 2012-09-26 PY - 2012 SN - 978-86-7083-762-1 N1 - Geburtsname von Köppe, Tabea: Wilk, T. - Birth name of Köppe, Tabea: Wilk, T. SP - 52 EP - 53 CY - Belgrade, Serbia AN - OPUS4-26638 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bartholmai, Matthias A1 - Werner, Klaus-Dieter A1 - Kammermeier, Michael A1 - Köppe, Tabea T1 - Multichannel measuring of strain and acceleration during high impact drop tests with a single cable system T2 - Sensoren und Messsysteme 2014 - 17. ITG/GMA-Fachtagung N2 - Multichannel measuring systems are used to measure strains and accelerations during drop tests of containments for dangerous goods. Conventional systems require cabling of each sensor and co-falling of the cable harness, causing problems in the test preparation and execution. Promising results of a single cable measuring system, consisting of measuring modules with data bus connection and local data acquisition were obtained in laboratory investigations and full-scale drop tests. T2 - Sensoren und Messsysteme 2014 - 17. ITG/GMA-Fachtagung CY - Nürnberg, Germany DA - 03.06.2014 KW - Multichannel measuring KW - Single cable system KW - Drop test PY - 2014 SN - 978-3-8007-3622-5 SN - 0932-6022 N1 - Geburtsname von Köppe, Tabea: Wilk, T. - Birth name of Köppe, Tabea: Wilk, T. N1 - Serientitel: ITG-Fachbericht – Series title: ITG-Fachbericht VL - 250 SP - Article 66, 1 EP - 5 PB - VDE Verlag GmbH AN - OPUS4-30859 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bartholmai, Matthias A1 - Kammermeier, Michael A1 - Werner, Klaus-Dieter A1 - Köppe, Tabea T1 - Single cable, multichannel measuring system for heavy load, high impact drop tests JF - Technisches Messen N2 - Multichannel measuring systems are used to measure strains and accelerations during drop tests of containments for dangerous goods. Conventional systems require cabling of each sensor and co-falling of the cable harness, causing problems in the test preparation and execution. Promising results of a single cable measuring system, consisting of measuring modules with data bus connection and local data acquisition were presented in a previous study. This paper follows up with results from laboratory and full-scale testing of an further enhanced single cable system for the application in drop tests.---------------------------------------------------------------------------------------------------------------------------------------------------------------- Vielkanalmesssysteme werden zur Messung von Dehnungen und Beschleunigungen bei Fallversuchen von Gefahrstoffbehältern eingesetzt. Konventionelle Systeme erfordern die Verkabelung jeder einzelnen Messstelle und somit das Mitfallen eines Kabelbaums, wodurch Probleme bei der Versuchsvorbereitung und Durchführung entstehen. In einer vorangegangenen Studie wurden vielversprechende Ergebnisse durch Verwendung eines 1-Kabelmesssystems mit Datenbus und dezentraler Datenspeicherung erzielt. Dieser Artikel beinhaltet weiterführende Ergebnisse aus Labor- und Realversuchen mit einem weiterentwickelten System zur Anwendung bei Fallversuchen. KW - Multichannel measuring system KW - Single cable measuring KW - Dangerous goods container KW - Drop test KW - High Impact testing KW - Hopkinson bar KW - Vielkanalmesssystem KW - Gefahrstoffe KW - Behälter KW - Fallprüfung KW - Hochdynamische Prüfung KW - Hopkinsonstab PY - 2013 DO - https://doi.org/10.1524/teme.2013.0033 SN - 0340-837X SN - 0178-2312 SN - 0171-8096 N1 - Geburtsname von Köppe, Tabea: Wilk, T. - Birth name of Köppe, Tabea: Wilk, T. VL - 80 IS - 7-8 SP - 249 EP - 255 PB - Oldenbourg CY - München AN - OPUS4-28963 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Köppe, Tabea A1 - Werner, Klaus-Dieter A1 - Kammermeier, Michael A1 - Bartholmai, Matthias T1 - Temperaturabhängige hochdynamische Untersuchungen des Systems Dehnungsmessstreifen/Klebstoff T2 - 16. ITG/GMA-Fachtagung - Sensoren und Messsysteme 2012 N2 - Dehnungsmessstreifen (DMS) gehören zu den Standardsensoren beim Messen mechanischer Größen. Sie finden Ihre Anwendung auf unterschiedlichen Gebieten, als sensorische Komponente in Messaufnehmern (z.B. Wägezelle, Kraftaufnehmer) oder für Dehnungsmessungen im Bereich der Strukturüberwachung unter anderem an Brücken oder Bauwerken. Sie werden in verschiedenen Größen geliefert und mit entsprechenden Klebstoffen auf der Objektoberfläche des Messobjekts an der jeweiligen Messstelle angebracht und an das Messsystem angeschlossen. Dieser Aufbau wird bei den verschiedenen Anwendungen unterschiedlichen Temperaturen und Umwelteinflüssen ausgesetzt. Dabei wird das System DMS/Klebstoff in seinen Eigenschaften verändert und das Ergebnis der Dehnungsmessung beeinflusst. Beispielsweise kann es zu einer Verfälschung der Messergebnisse kommen, wenn der Klebstoff die Dehnung des Messobjekts nicht vollständig auf den DMS überträgt, oder es kann eine Nullpunktverschiebung der Dehnungsmessung auftreten. An der Bundesanstalt für Materialforschung und -prüfung werden Fallversuche von Lager- und Transportbehältern durchgeführt. Für diese werden Dehnungsmessstreifen auf den Behälter angebracht um die Dehnung bzw. Verformung zu messen. Bei den Versuchen werden verschiedene Parameter berücksichtigt: Neben unterschiedlichen Fallhöhen (u.a. 9 m und 1 m) wird auch der Temperatureinfluss auf den Fallversuch z.B. bei -40 °C oder +100 °C untersucht. Zur Applizierung von DMS auf Objektoberflächen gibt es für verschiedene Anwendungsbedingungen (DMS-Typ, Objektoberflächenbeschaffenheit, Einsatztemperatur) von den DMS-Herstellern jeweils empfohlene Klebstoffe. Insbesondere für Anwendungsfälle mit hochdynamischer Belastung (Fallversuche, Crash-Tests) und großem Temperaturbereich ist es erforderlich, dass die Dehnungsmessstreifen zuverlässige Werte ausgeben. Dies ist nur gegeben, wenn der Klebstoff eine gute Verbindung zwischen Messobjekt und Dehnungsmessstreifen herstellt. T2 - 16. GMA/ITG-Fachtagung 'Sensoren und Messsysteme' CY - Nürnberg, Germany DA - 2012-05-22 KW - Hopkinson-Stab KW - Dehnungsmessstreifen KW - Temperaturabhängige Prüfung KW - Klebstoffe KW - Hochdynamische Untersuchungen PY - 2012 SN - 978-3-9813484-0-8 DO - https://doi.org/10.5162/sensoren2012/4.1.4 N1 - Geburtsname von Köppe, Tabea: Wilk, T. - Birth name of Köppe, Tabea: Wilk, T. SP - 435 EP - 442 CY - Wunstorf AN - OPUS4-26009 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Köppe, Tabea A1 - Werner, Klaus-Dieter A1 - Kammermeier, Michael A1 - Bartholmai, Matthias ED - Jirousek, O. ED - Kytýr, D. T1 - Temperature-dependent dynamic analysis of the system strain gauge/adhesive T2 - XIIIth Bilateral Czech/German Symposium - Experimental Methods and Numerical Simulation in Engineering Sciences (Proceedings) T2 - XIIIth Bilateral Czech/German symposium - Experimental methods and numerical simulation in engineering sciences CY - Telc, Czech Republic DA - 2012-06-05 KW - Hopkinson pressure bar KW - Temperature dependent and high dynamic load tests KW - System adhesive/ strain gauge PY - 2012 SN - 978-80-01-05062-0 N1 - Geburtsname von Köppe, Tabea: Wilk, T. - Birth name of Köppe, Tabea: Wilk, T. IS - 1 SP - 99 EP - 102 PB - CTU AN - OPUS4-26027 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -