TY - JOUR A1 - Moufid, M. A1 - Bouchikhi, B. A1 - Tiebe, Carlo A1 - Bartholmai, Matthias A1 - El Bari, N. T1 - Assessment of outdoor odor emissions from polluted sites using simultaneous thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS), electronic nose in conjunction with advanced multivariate statistical approaches N2 - Poor air quality, particularly in urban areas, causes various diseases and degrades living standards. Air Quality could be affected by emissions of odor, Volatile Organic Compounds (VOCs), and other gases. Therefore, assessment and monitoring of odorous air quality using sensitive, simple, rapid, accurate and portable tools is very important for public health. This study aimed to characterize odor emissions to detect malfunctions in facilities and to prevent air pollution and olfactory nuisance in the environment. A gas chromatographic method, in conjunction with sensorial analysis were performed for odorous air samples analysis collected from neighborhood of Meknes city (Morocco). Advanced multivariate statistical approaches, such as Principal Components Analysis (PCA), Discriminant Function Analysis (DFA), Support Vector Machines (SVMs), and Hierarchical Cluster Analysis (HCA), were used to describe samples similarities. The electronic nose (e-nose) data processing exhibits a satisfactory discrimination between the odorous air samples. Twenty-four VOCs with known molecular formulas were identified with Thermal Desorption-Gas Chromatography-Mass Spectrometry (TD-GC-MS). A validated Partial Least Square (PLS) model foresees good calibration between e-nose measurement and TD-GCMS analysis. The finding indicates that TD-GC–MS approach in conjunction with e-nose unit could be suitable tool for environmental measurement-based odor emissions. KW - Electronic nose KW - TD-GC-MS KW - PLS regression KW - Multivariate analysis KW - Outdoor odor emissions PY - 2021 DO - https://doi.org/10.1016/j.atmosenv.2021.118449 SN - 1352-2310 VL - 256 SP - 118449 PB - Elsevier Ltd. AN - OPUS4-52626 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Johann, Sergej A1 - Bartholmai, Matthias A1 - Neumann, Patrick P. A1 - Tiebe, Carlo A1 - Gawlitza, Kornelia A1 - Bartelmeß, Jürgen T1 - Adaptable multi-sensor device for gas detection N2 - Innovation is the catalyst for the technology of the future. It is important to develop new and better technologies that can continuously monitor the environmental impact, e.g., for air quality control or emission detection. In the recently at BAM developed Universal Pump Sensor Control (UPSC3) module, different components and sensors are fused. The combination of the individual components makes the UPSC3 module an excellent monitoring and reference system for the development and characterization of gas specific sensors. Measurements over long periods are possible, for mixed gas loads or for certain gas measurements. The system is part of a mobile sensor network of several sensor units, which can also be used as standalone systems. The motivation and objective of this research is to develop gas sensors based on fluorescence detection with range of ppm / ppb. For this task a reference system is required, which contains volatile organic compound (VOC) sensors for reference data from different scenarios. The integrated multi-sensor unit can measure different gases through the integrated 3-fold VOC sensor, which can be adapted to the addressed scenario. . The system-integrated flow control, with pump and flow sensor, allows the gas molecules to be transported directly to the VOC sensor. The entire measurement is permanently stored on an integrated memory card. If the previously determined limit range is exceeded, an alarm is generated. The system is an important tool towards further developments in the field of gas sensors and is primarily used for the validation of chemically based gas sensors. T2 - Colloquium of Optical Spectrometry (COSP) 2017 CY - Berlin, Germany DA - 27.11.2017 KW - Gas detection KW - Multi sensor device KW - Pump control KW - VOC PY - 2017 AN - OPUS4-43193 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Moufid, M. A1 - Tiebe, Carlo A1 - El Bari, N. A1 - Bartholmai, Matthias A1 - Bouchikhi, B. T1 - Combining of TD-GC-MS and home developed electronic nose for road traffic air monitoring N2 - In this work, we demonstrate the ability of an electronic nose system based on an array of six-semiconductor gas sensors for outdoor air quality monitoring over a day at a traffic road in downtown of Meknes city (Morocco). The response of the sensor array reaches its maximum in the evening of the investigated day which may due to high vehicular traffic or/and human habits resulting in elevated concentrations of pollutants. Dataset treatment by Principal Component Analysis and Discriminant Function Analysis shows a good discrimination between samples collected at different times of the day. Moreover, Support Vector Machines were used and reached a classification success rate of 97.5 %. Thermal Desorption-Gas Chromatography-Mass Spectrometry (TD-GC-MS) technique was used to validate the developed e-nose system by identifying the composition of the analyzed air samples. The discrimination obtained by e-nose system was in good agreement with the TD-GC-MS results. This study demonstrates the usefulness of TD-GC-MS and e-nose, providing high accuracy in discriminating outdoor air samples collected at different times. This demonstrates the potential of using the e-nose as a rapid, easy to use and inexpensive environmental monitoring system. T2 - 2021 IEEE International Conference on Design & Test of Integrated Micro & Nano-Systems (DTS) CY - Sfax, Tunisia DA - 07.06.2021 KW - GC-MS KW - Electronic nose KW - Gas sensors KW - Urban air monitoring PY - 2021 DO - https://doi.org/10.1109/DTS52014.2021.9498110 SP - 1 EP - 6 AN - OPUS4-54401 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Neumann, Patrick P. A1 - Tiebe, Carlo A1 - Bartholmai, Matthias T1 - Airborne Remote Gas Sensing and Mapping N2 - Leaking methane (CH4) from infrastructures, such as pipelines and landfills, is critical for the environment but can also pose a safety risk. To enable a fast detection and localization of these kind of leaks, we developed a novel robotic platform for aerial remote gas sensing. Spectroscopic measurement methods for remote sensing of selected gases lend themselves for use on mini-copters, which offer a number of advantages for inspection and surveillance over traditional methods. No direct contact with the target gas is needed and thus the influence of the aerial platform on the measured gas plume can be kept to a minimum. This allows to overcome one of the major issues with gas-sensitive mini-copters. On the other hand, remote gas sensors, most prominently Tunable Diode Laser Absorption Spectroscopy (TDLAS) sensors have been too bulky given the payload and energy restrictions of mini-copters. Here, we present the Unmanned Aerial Vehicle for Remote Gas Sensing (UAV-REGAS), which combines a novel lightweight TDLAS sensor with a 3-axis aerial stabilization gimbal for aiming on a versatile hexacopter. The proposed system can be deployed in scenarios that cannot be addressed by currently available robots and thus constitutes a significant step forward for the field of Mobile Robot Olfaction (MRO). It enables tomographic reconstruction of gas plumes and a localization of gas sources. We also present first results showing its performance under realistic conditions. T2 - Networked Environmental Monitoring – from sensor principles to novel services CY - BAM, Berlin, Germany DA - 06.02.2018 KW - Localization of gas sources KW - Mobile Robot Olfaction KW - Tomographic reconstruction of gas plumes KW - Tunable Diode Laser Absorption Spectroscopy (TDLAS) KW - UAV-REGAS PY - 2018 AN - OPUS4-44085 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Köppe, Enrico A1 - Bartholmai, Matthias A1 - Prager, Jens T1 - Device concept for the generation of guided waves for early damage detection N2 - In this study a method for early damage detection is investigated based on the directed excitation and measuring of Lamb waves (guided waves). The objective is to make a statement about the practicability of a Lamb wave generator (LWG) and about the application relevant parameters (specimen materials and dimensions, wave characteristics, excitation, transmission und reflection). Guided waves enable an effective differentiation of structural and defective indications as well as a classification of different defect types. For the investigations, a LWG was developed which combines the advantages of the single excitation of a piezoelectric actuator and the possibility of a group excitation. Algorithms were developed to identify and analyze damage patterns (cracks, wholes, weakening). T2 - Eurosensors XXVI CY - Kraków, Poland DA - 09.09.2012 KW - Lamb wave KW - Guided wave KW - DDS KW - SHM KW - Early damage detection PY - 2012 DO - https://doi.org/10.1016/j.proeng.2012.09.363 SN - 1877-7058 VL - 47 SP - 1185 EP - 1188 PB - Elsevier AN - OPUS4-27552 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Köppe, Enrico A1 - Bartholmai, Matthias A1 - Liers, A. A1 - Schiller, J. T1 - Radio-based multi-sensor system for person tracking and indoor positioning N2 - Sensor based person tracking is a challenging topic. The main objective is positioning in areas without GPS connection, i.e. indoors. A research project is carried out at BAM, Federal Institute for Materials Research and Testing, to develop and to validate a multi-sensor system for 3D localization. It combines body motion sensing and a guard system for the tracking and recording of the status of persons. The so named BodyGuard system was designed for sensor-based monitoring and radio-based transmission of the movement of a person. Algorithms were developed to transform the sensor data into a spatial coordinate. Thispaper describes how the BodyGuard system operates, which main components were used in the system, how the individual sensor data are converted into 3D motion data, with which algorithms the individual sensors are processed, how individual errors are compensated and how the sensor data are merged into a 3D Model. Final objective of the BodyGuard system is to determine the exact location of a person in a building, e.g. during fire-fighting operations. T2 - WPNC '12 - 9th Workshop on positioning, navigation and communication 2012 CY - Dresden, Germany DA - 15.03.2012 KW - Wireless sensor network (WSN) KW - Embedded systems KW - Sensor calibration and validation KW - Person tracking KW - Inertial navigation system KW - Inertial measurement unit PY - 2012 IS - PS 11 SP - 1 EP - 7 CY - Dresden AN - OPUS4-26028 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hohendorf, Stefan A1 - Bartholmai, Matthias T1 - Intelligente Gefahrgutbehälter - IBC mit Gedächtnis N2 - Trotz strenger gesetzlicher Regelungen kommt es immer wieder zu schwerwiegenden Unfällen und Mängeln beim Transport und der Lagerung von Gefahrgütern. Die Ursachen dafür sind oft technisches, aber auch menschliches Versagen. Nicht zu unterschätzen ist die ständig wachsende Anzahl von Gefahrguttransporten auf deutschen Straßen. Waren 2002 noch 126 Mio. t Fracht mit Gefahrguttransporten im Straßenverkehr unterwegs, stieg die Frachtmenge im Jahr 2008 bereits auf 171 Mio. t. In den letzen Jahren ereigneten sich nach Angaben des statistischen Bundesamtes etwa 300 schwere Unfälle, an denen Gefahrguttransporte beteiligt waren. Allein 2009 wurden 1 372 Unfälle mit wassergefährdenden Stoffen registriert, wobei insgesamt 376 000 l wassergefährdende Stoffe freigesetzt wurden. KW - Gefahrgut KW - RFID KW - BAM Datenbank Gefahrgut KW - Monitoring KW - Ladungsssicherung PY - 2012 UR - http://www.technischesicherheit.de/ts/currentarticle.php?data[article_id]=67080 SN - 2191-0073 VL - 2 IS - 5 SP - 2 EP - 4 PB - Springer-VDI-Verl. CY - Düsseldorf AN - OPUS4-25904 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -