TY - JOUR A1 - Neumann, Patrick P. A1 - Hirschberger, Paul A1 - Bartholmai, Matthias ED - Zemčík, R. ED - Krystek, J. T1 - Influence of rotor downwash on vertically displaced nanobots in flight N2 - One challenge associated with navigating a nano aerial robot swarm indoors in unstructured environments is, i.a., the limited air space. To avoid an over-regulation of the available indoor air space (e.g., prohibit copters to fly above each other), a safety region around each copter must be defined. In this paper, we investigate the impact of the downwash of a nano-drone on the stability of another nearby nano-drone. In the experiments, we found out that this downwash has a negative influence of a second nano-drone in a distance of around 1 m vertically and 0.2 m horizontally. Based on the obtained data, we developed a model describing the above-mentioned safety region to enable a safe operation of the swarm in these environments with fewer constraints. T2 - 36th Danubia-Adria Symposium on Advances in Experimental Mechanics CY - Pilsen, Czech Republic DA - 24.09.2019 KW - Mobile Robot Olfaction KW - Nano aerial robot KW - Swarm KW - Collision-free navigation KW - Safety region model PY - 2020 DO - https://doi.org/10.1016/j.matpr.2020.03.047 VL - 32 IS - 2 SP - 108 EP - 111 PB - Elsevier Ltd. CY - Amsterdam AN - OPUS4-50673 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Neumann, Patrick P. A1 - Hirschberger, Paul A1 - Bartholmai, Matthias T1 - Flying Ant Robot – Aerial Chemical Trail Detection and Localization N2 - This paper presents first advances in the area of aerial chemical trail following. For that purpose, we equipped a palm-size aerial robot, based on the Crazyflie 2.0 quadrocopter, with a small lightweight metal oxide gas sensor for measuring evaporated ethanol from chemical trails. To detect and localize the chemical trail, a novel detection criterion was developed that uses only relative changes in the transient phase of the sensor response, making it more robust in its application. We tested our setup in first crossing-trail experiments showing that our flying ant robot is able to correlate an odor hit with the chemical trail within 0.14 m. Principally, this could enable aerial chemical trail following in the future. T2 - IEEE Sensors 2021 CY - Online meeting DA - 31.10.2021 KW - Nano aerial robot KW - Trail following KW - Trail detection KW - Localization PY - 2021 DO - https://doi.org/10.1109/sensors47087.2021.9639857 SP - 1 EP - 4 PB - IEEE AN - OPUS4-53933 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ullner, Christian A1 - Subaric-Leitis, Andreas A1 - Bartholmai, Matthias T1 - Uncertainty of Elastoplastic Material Parameters Calculated from the Spherical Indentation in the Macro Range N2 - The applicability of three methods developed by finite element analysis (FEM) and proposed in the literature are studied on steel S355. Instrumented indentation tests using spherical indenters of radius 200 and 500 μ m are performed in the macro range at depths of more than 6 μ m. The results of the selected methods are compared with the tensile test. To evaluate the partially strongly varying results, the uncertainties of the calculated strain hardening exponent, n, and yield stress, Y, are estimated. Recommendations for an appropriated procedure of the indentation test are given. The machine compliance and the determination of the zero point of Depth play an essential role. If the certain conditions are considered, the instrumented indentation Tests can be used, in particular for investigations of specimens with inhomogeneous elastoplasticity. KW - Indentation KW - Elastoplastic material parameters KW - Uncertainty PY - 2021 DO - https://doi.org/10.1520/JTE20200683 SN - 0090-3973 VL - 49 IS - 6 SP - 4576 EP - 4592 PB - ASTM International AN - OPUS4-52416 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Neumann, Patrick P. A1 - Hirschberger, Paul A1 - Bartholmai, Matthias ED - Holl, H. T1 - Flying ant robot for chemical trail detection and localization N2 - This paper presents first advances in the area of aerial chemical trail following. For that purpose, we equipped a palm-size aerial robot, based on the Crazyflie 2.0 quadrocopter, with a small lightweight metal oxide gas sensor for measuring evaporated ethanol from chemical trails. To detect and localize a 5 cm wide chemical trail, a detection criterion was developed that uses only relative changes in the transient phase of the sensor response. The reduction in signal strength dependence improves the robustness of its application. We tested our setup in first crossing-trail experiments showing that our flying ant robot can correlate an odor hit with the chemical trail within 0.14 m. Principally, this could enable aerial chemical trail following in the future. T2 - 37th Danubia - Adria Symposium on Advances in Experimental Mechanics CY - Linz, Austria DA - 21.09.2021 KW - Aerial robot KW - Trail following KW - Trail detection KW - Localization PY - 2022 DO - https://doi.org/10.1016/j.matpr.2022.02.594 SN - 2214-7853 VL - 62 SP - 2462 EP - 2465 PB - Elsevier Ltd. CY - Amsterdam AN - OPUS4-54507 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Johann, Sergej A1 - Stührenberg, Jan A1 - Tandon, Aditya A1 - Dragos, Kosmas A1 - Bartholmai, Matthias A1 - Strangfeld, Christoph A1 - Smarsly, Kay T1 - Investigation of long-term embedded RFID sensors for structural health monitoring N2 - Ensuring the health of civil engineering structures is crucial for the safety and longevity of the built environment. In this direction, structural health monitoring (SHM) has been increasingly employed, providing insight into the structural behavior, based on sensor data representing structural responses. This paper investigates the plausibility of embedding sensors into concrete structures for SHM, leveraging radio frequency identification (RFID) technology, in an attempt to enable the passive operation of sensors without continuous power supply and to reduce potential sources of interference. In contrast to conventional SHM sensors, the uninterrupted operation of embedded sensors must be ensured because post-installation interventions are either impractical or impossible. RFID technology enables wireless data acquisition and energy transmission without mechanical impact on civil engineering structures, although it may be challenging when RFID sensors are embedded in concrete. This study presents a durable passive embedded RFID sensor system (i.e., a system without batteries), including the selection of components, such as housing and cable materials, suitable for withstanding the aggressive environment of concrete without damaging the sensitive electronics or contaminating the data recorded by the sensors. The proposed sensor system is validated in laboratory tests, the results of which provide insights into the influence of each component and are intended to advance the implementation of embedded sensor systems. T2 - IEEE Sensors 2024 CY - Kobe, Japan DA - 20.10.2024 KW - Structural health monitoring KW - RFID-based sensors KW - Smart sensors KW - Embedded sensors PY - 2024 SN - 979-8-3503-6351-7 DO - https://doi.org/10.1109/SENSORS60989.2024.10785220 SP - 1 EP - 4 AN - OPUS4-62162 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bartelmeß, Jürgen A1 - Zimmek, David A1 - Bartholmai, Matthias A1 - Strangfeld, Christoph A1 - Schäferling, M. T1 - Fibre optic ratiometric fluorescence pH sensor for monitoring corrosion in concrete N2 - In this communication a novel concept for pH sensing is introduced which is specifically adapted to monitor carbonation induced corrosion in concrete structures. The method is based on a ratiometric measurement principle, exploiting the pH sensitive colour switching of thymol blue in the basic pH regime and the emissive properties of two different (Zn)CdSe/ZnS core shell quantum dots. The transition point of thymol blue in a Hydrogel D4 matrix was determined to be at around pH 11.6, which fits ideally to the intended application. Next to the fundamental spectroscopic characterization of the ratiometric response, a new design for a sensor head, suitable for the incorporation into concrete matrices is presented. Toward this, a manufacturing process was developed which includes the preparation of a double layer of polymers containing either thymol blue or a quantum dot mixture inside a porous ceramic tube. Results of a proof-of-priciple performance test of the sensor head in solutions of different pH and in cement specimens are presented, with encouraging results paving the way for future field tests in concrete. KW - Fiber optic sensing KW - PH monitoring in concrete KW - Embedded sensors KW - Ratiometric fluorescence PY - 2020 DO - https://doi.org/10.1039/c9an02348h VL - 145 IS - 6 SP - 2111 EP - 2117 PB - Royal Society of Chemistry AN - OPUS4-50381 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Mansurova, Maria A1 - Johann, Sergej A1 - Kohlhoff, Harald A1 - Rurack, Knut A1 - Bartholmai, Matthias A1 - Bell, Jérémy T1 - On-Site Analytical Tool Based on Crude Oil Fluorescence and Chemometrics for the Rapid Determination of the Nature and Essential Properties of Oil Spills N2 - With the reduction of large oil spills because of stricter regulations and safety measures, the question of how to manage smaller oil spills arises. Few on-site analytical tools are available for first responders or other law enforcement personnel to rapidly test for crude oil in the early management of localized polluted areas. The approach reported here relies on well-described computer-assisted multivariate data analysis of the intrinsic fluorescence fingerprints of crude oils to build a multivariate model for the rapid classification of crude oils and the prediction of their properties. Thanks to a dedicated robust portable reader, the method allowed classification and accurate prediction of various properties of crude oil samples like density (according to API, the American Petroleum Institute and viscosity as well as composition parameters such as volume fractions of paraffins or aromatics. In this way, autonomous operation in on-site or in-the-field applications becomes possible based on the direct (undiluted and untreated) measurement of samples and a rapid, tablet-operated readout system to yield a robust and simple analytical test with superior performance. Testing in real-life scenarios allowed the successful classification and prediction of a number of oil spill samples as well as weathered samples that closely resemble samples collected by first responders. KW - Oil spills KW - Fluorescence KW - PCA KW - Petroleum KW - Rapid test KW - Portable PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-595442 DO - https://doi.org/10.1021/acsestwater.3c00648 VL - 4 IS - 2 SP - 621 EP - 627 PB - American Chemical Society (ACS) AN - OPUS4-59544 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Mansurova, Maria A1 - Gotor, Raúl A1 - Johann, Sergej A1 - Neumann, Patrick P. A1 - Bartholmai, Matthias A1 - Rurack, Knut A1 - Bell, Jérémy T1 - Fluorescent Hydrophobic Test Strips with Sterically Integrated Molecular Rotors for the Detection of Hydrocarbons in Water and Soil with an Embedded Optical Read-Out N2 - Contamination of natural bodies of water or soil with oils and lubricants (or generally, hydrocarbon derivatives such as petrol, fuels, and others) is a commonly found phenomenon around the world due to the extensive production, transfer, and use of fossil fuels. In this work, we develop a simple system for the on-field detection of total petroleum hydrocarbons (TPHs) in water and soil. The test is based on the measurement of the fluorescence signal emitted by the molecular rotor 2-[ethyl[4-[2-(4-nitrophenyl)ethenyl]phenyl]amino]ethanol (4-DNS-OH). This dye is embedded in a hydrophobic polymeric matrix (polyvinylidene fluoride), avoiding interactions with water and providing a robust support for use in a test strip fashion. Together with the strips, an embedded optical system was designed for fluorescence signal read-out, featuring a Bluetooth low-energy connection to a commercial tablet device for data processing and analysis. This system works for the detection and quantification of TPHs in water and soil through a simple extraction protocol using a cycloalkane solvent with a limit of detection of 6 ppm. Assays in surface and sea waters were conclusive, proving the feasibility of the method for in-the-field operation. KW - Test strip KW - Sensor KW - Smartphone KW - Fluorescence KW - Test Streifen KW - Sensoren KW - Fluoreszenz KW - Petrol KW - Öl PY - 2023 DO - https://doi.org/10.1021/acs.energyfuels.3c01175 SN - 0887-0624 SP - 1 EP - 6 PB - American Chemical Society CY - Washington, United States AN - OPUS4-57892 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Moufid, M. A1 - Tiebe, Carlo A1 - El Bari, N. A1 - Bartholmai, Matthias A1 - Bouchikhi, B. T1 - Advance in electronic nose technology developed for the detection and discrimination of ethanol, ammonia, and hydrogen sulfide gases N2 - This work focuses on the design and fabrication of low-cost and fast-response of an electronic nose (E-nose) based on semiconductor gas sensors, for discriminating some synthetic gases such as ammonia (NH3), ethanol (C2H5OH), and hydrogen sulfide (H2S). Additionally, the capability of separating different concentration levels of each considered gases was checked. Dataset treatment of E-nose by using Principal Component Analysis (PCA) showed a good discrimination of the different synthetic gases. Furthermore, perfect classification was reached of different concentration levels of the analysed gases by using Discriminant Function Analysis (DFA). In the light of these results, it could be stated that the developed E-nose system constitutes an inexpensive, rapid, simple to use, and efficient tool for synthetic gases detection. T2 - IEEE International Symposium on Olfaction and Electronic Nose (ISOEN) CY - Aveiro, Portugal DA - 29.05.2022 KW - Electronic nose KW - Metal oxide semiconductor KW - Chemometric techniques KW - Environmental analysis PY - 2022 SN - 978-1-6654-5860-3 DO - https://doi.org/10.1109/ISOEN54820.2022.9789636 SP - 1 EP - 3 AN - OPUS4-56574 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Moufid, M. A1 - Tiebe, Carlo A1 - El Bari, N. A1 - Hamada, D. A. A1 - Bartholmai, Matthias A1 - Bouchikhi, B. T1 - Pollution parameters evaluation of wastewater collected at different treatment stages from wastewater treatment plant based on E-nose and E-tongue systems combined with chemometric techniques N2 - Wastewater contains harmful chemicals and heavy metals that are known to cause various environmental and health problems. Therefore, the water quality control using sensitive, simple, fast, accurate, and portable tools is of great importance. This study aimed to evaluate the pollution parameters of wastewaters collected at different treatment stages from a wastewater treatment plant (WWTP) that treats domestic and industrial wastewaters by using an electronic nose (E-nose) and a voltammetric electronic tongue (E-tongue) combined with chemometric techniques. Water and wastewater pollution parameters determination were performed using inductively coupled plasma optical emission spectrometry for the determination of cations, and anions by using ion chromatography. Chemometric techniques, such as Principal Component Analysis (PCA), Discriminant Function Analysis (DFA), Support Vector Machines (SVMs), and Hierarchical Cluster Analysis (HCA), were used to process the E-nose and E-tongue datasets to describe the similarities between the samples. In addition, Partial Least Squares Regression (PLSR) model was constructed using electronic sensing data to simultaneously predict the concentration values of physicochemical parameters. The obtained correlation coefficient, for training and testing sets, is higher than 0.91 for the prediction of the concentration of all physicochemical parameters, except for iron (Fe) which remains 0.84. These results suggest that simple, portable, and inexpensive tools such as electronic nose and tongue are suitable for wastewater analysis. KW - Wastewater KW - Electronic nose KW - Voltammetric electronic tongue KW - Water quality control KW - Chemometric techniques KW - Gas sensing PY - 2022 DO - https://doi.org/10.1016/j.chemolab.2022.104593 VL - 227 SP - 1 EP - 12 PB - Elsevier B.V. AN - OPUS4-55652 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -