TY - CONF A1 - Ziegler, Mathias A1 - Thiel, Erik A1 - Ahmadi, Samim T1 - Lock-in Thermography using High-Power Laser Sources N2 - Optical lock-in thermography is a completely contactless and very sensitive NDT technique. As an optical source of energy, incandescent (i.e. halogen) lamps are most commonly used because they are relatively inexpensive and offer high irradiances at the test site. However, they are strongly restricted by their low modulation bandwidth with a maximum modulation frequency of only about 1 Hz. The use of high-power kilowatt-class laser sources, e.g. diode laser arrays, pushes this constraint beyond 100 Hz, see Fig.1. This allows for the exploration of the near-surface region of metals and layer systems with better and more accurate penetration depth and depth resolution. Moreover, these lasers are virtually free of any additional thermal radiation that could interfere with the “true” thermal response emitted from the heated sample. In turn, they can be easily used in a one-sided test configuration. Using the one-dimensional solution to the thermal heat diffusion equation together with the absorptance of the material which is illuminated with a harmonically modulated light source, we can calculate the temperature oscillation at the surface of a solid. As a second step, we calculate the corresponding oscillation of the total thermal emission using Stefan-Boltzmann law as a first order approximation and taking into account the emissivity of the material. Within this framework we can calculate the minimal irradiance of a light source necessary to provoke a measurable signal within a thermographic camera at a noise equivalent temperature difference (NETD) of 30 mK. In Fig. 2 this relationship is displayed for a wide spectrum of modulation frequencies and for a number of different light sources scaled to the same electrical input power and illumination area. Using this figure, it is now easily possible to analyze the range of materials to be tested using lock-in thermography, since only the materials (dotted lines) below the irradiance-vs-frequency curves (solid lines) are heated in excess of the camera’s NETD. This figure clearly shows that laser sources considerably increase the application range of lock-in thermography, since especially for metals with a high reflectance and high thermal diffusivity a high irradiance is vitally important to allow for lock-in texting. We present current activities with kilowatt-class high-power laser sources for advanced lock-in thermography and focus on the application of laser arrays that offer a very high irradiation strength over a large sample area beyond the mentioned advantages. T2 - Conference QIRT 2018 CY - Berlin, Germany DA - 25.06.2018 KW - Thermography KW - Laser Thermography KW - Lock-in Thermography PY - 2018 AN - OPUS4-45447 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ziegler, Mathias A1 - Ahmadi, Samim A1 - Thiel, Erik A1 - Krankenhagen, Rainer A1 - Maierhofer, Christiane T1 - Benefits & peculiarities of using highpower lasers for lock-in thermography N2 - Optical lock-in thermography is a completely contactless and very sensitive NDE technique. As an optical source of energy, incandescent (i.e. halogen) lamps are most commonly used because they are relatively inexpensive, do not need any work safety measures and offer high irradiances at the test site. However, they are strongly restricted by their low modulation bandwidth with a maximum modulation frequency of only about 1 Hz. The use of high-power kilowatt-class laser sources, e.g. diode laser arrays, pushes this constraint beyond 100 Hz. This allows for the exploration of the near-surface region of metals and layer systems with better and more accurate penetration depth and depth resolution. Moreover, these lasers are virtually free of any additional thermal radiation that could interfere with the “true” thermal response emitted from the heated sample. In turn, they can be easily used in a one-sided test configuration. Altogether using lasers considerably increases the application range of lock-in thermography, since especially for metals with a high reflectance and high thermal diffusivity a high irradiance is vitally important to allow for lock-in testing [1, 2]. We report on the mentioned benefits of using such high-power lasers and analyze the range of materials to be tested using lock-in thermography in dependence on the laser irradiance, the modulation frequency, the infrared camera as well as the optical and thermal material parameters. In this context, we also address a number of systematic errors caused by the use of ideal and non-ideal heat sources. For example, the measured phase angle in lock-in thermography depends on the irradiance and the modulation bandwidth of the source. This in turn has a decisive influence on the uncertainty in the quantification of, e.g. layer thicknesses. T2 - INTERNATIONAL SCHOOL OF QUANTUM ELECTRONICS, 62nd Course, Progress in Photoacoustic & Photothermal Phenomena CY - Erice, Italy DA - 06.09.2018 KW - Thermography KW - Laser thermography KW - Lock-in thermography KW - NDT PY - 2018 AN - OPUS4-46282 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ziegler, Mathias A1 - Šrajbr, C. A1 - Müller, D. T1 - Aktueller Stand der Normung in der Thermografie N2 - Die Thermografie ist trotz ihrer ausgereiften wissenschaftlichen und technologischen Grundlagen ein noch relativ junges Mitglied in der Familie der zerstörungsfreien Prüfverfahren. Sie erschließt sich aufgrund einer Reihe von Vorzügen eine wachsende Anwendungsgemeinde. Für eine weitere Verbreitung insbesondere im industriellen Kontext spielen Normen, Standards und technische Regeln eine wichtige Rolle. In diesem Beitrag wird der aktuelle Stand der Normung in Deutschland vorgestellt. Wir zeigen, welche Normen und technischen Regeln es für die Thermografie in Deutschland und international gibt und wir wagen einen Blick in die Zukunft. Darüber hinaus lebt auch die Normierungsarbeit von der Beteiligung durch interessierte Kreise. Dies können industrielle und akademische Anwender*innen, Hersteller*innen von Geräten, Forschungseinrichtungen oder Dienstleistungsunternehmen sein. Sie können gern Ihre Bedarfe bezüglich Normierungsprojekten mitbringen und/oder direkt an die Autoren senden. T2 - DACH-Jahrestagung 2023 CY - Friedrichshafen, Germany DA - 15.05.2023 KW - Thermografie KW - Zerstörungsfreie Prüfung KW - Normung KW - Standardisierung PY - 2023 AN - OPUS4-59250 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ziegler, Mathias A1 - Lecompagnon, Julien A1 - Hirsch, Philipp Daniel A1 - Rupprecht, C. T1 - Thermographic super resolution reconstruction using 2D pseudo-random pattern illumination N2 - Thermographic non-destructive testing is based on the interaction of thermal waves with inhomogeneities. The propagation of thermal waves from the heat source to the inhomogeneity and to the detection surface according to the thermal diffusion equation leads to the fact that two closely spaced defects can be incorrectly detected as one defect in the measured thermogram. In order to break this spatial resolution limit (super resolution), the combination of spatially structured heating and numerical methods of compressed sensing can be used. The improvement of the spatial resolution for defect detection then depends in the classical sense directly on the number of measurements. Current practical implementations of this super resolution detection still suffer from long measurement times, since not only the achievable resolution depends on performing multiple measurements, but due to the use of single spot laser sources or laser arrays with low pixel count, also the scanning process itself is quite slow. With the application of most recent high-power digital micromirror device (DMD) based laser projector technology this issue can now be overcome. T2 - ICPPP21: International Conference on Photoacoustic and Photothermal Phenomena CY - Bled, Slovenia DA - 19.06.2022 KW - Thermography KW - Super resolution KW - NDT KW - Inspection KW - Internal defects KW - DMD KW - DLP PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-551224 UR - https://indico.ung.si/event/5/contributions/237/ AN - OPUS4-55122 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Myrach, Philipp A1 - Ziegler, Mathias A1 - Unnikrishnakurup, Sreedhar A1 - Puthiyaveettil, N. A1 - Kruschke, H. A1 - Balasubramaniam, Krishnan T1 - Online Laser-thermografische Rissprüfung an Stahl bei hohen Temperaturen N2 - Die Detektion bzw. Charakterisierung von Oberflächenrissen in Stahl ist eine herausfordernde Aufgabe für die zerstörungsfreie Prüfung. Dies gilt insbesondere, wenn eine solche Prüfung bereits während der Produktion selbst erfolgen soll. Die hier vorgefundenen Randbedingungen, wie z.B. die hohen Probentemperaturen (>700°C) oder Vorschubgeschwindigkeiten von bis zu 0,9 m/min, machen die Anwendung etablierter und vor allem berührender ZfP-Methoden praktisch meist unmöglich. Laser-thermografische Verfahren können hier eine Alternative bieten, da sie berührungslos und schnell arbeiten. Wir stellen die Ergebnisse einer Weiterentwicklung der Laser-thermografischen Prüfung vor, bei der die Anwendbarkeit bzw. die Übertragbarkeit der Methode auf die Bedingungen der Stahlproduktion untersucht wurde. Neben der Simulation der Produktionsbedingungen im Labor und der experimentellen Untersuchung der entscheidenden Einflussgrößen, wurden umfangreiche FEM-Simulationen durchgeführt. Mit Hilfe dieser theoretischen und experimentellen Ergebnisse wurde das Verfahren auch hinsichtlich der Analyse-Algorithmen weiterentwickelt, um eine zuverlässige und schnelle In-Line Prüfung während des Produktionsprozesses zu ermöglichen. Um zudem die Fähigkeiten der Thermografiekamera für schnelle online-Messungen und ihre Integrierbarkeit in verschiedene Anwendungssysteme zu verbessern, wurde die für die Verarbeitung der Detektordaten erforderliche Non-Uniformity Correction der Pixeldaten auf schneller Spezialhardware innerhalb der Kamera implementiert. T2 - Thermografie-Kolloquium 2017 CY - Berlin, Germany DA - 28.09.2017 KW - Rissprüfung KW - Laserthermografie KW - Thermografie KW - Risse PY - 2017 AN - OPUS4-42922 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Maierhofer, Christiane A1 - Ziegler, Mathias T1 - Neue Normen und Richtlinien für die Thermografie in der zerstörungsfreien Prüfung N2 - Da die Thermografie als zerstörungsfreies Prüfverfahren noch vergleichsweise neu in der Anwendung ist, beziehen sich die aktuell veröffentlichten und überarbeiteten Normen und Richtlinien im Wesentlichen auf die grundlegenden Prinzipien des Verfahrens und die verschiedenen Anregungs- und Auswertungstechniken, auf die Begriffe und auf die Gerätetechnik. Die grundlegenden Normen zum Prinzip des Prüfverfahrens, zu den Geräten und zu den Begriffen wurden in 2016 grundlegend überarbeitet und als CEN-Normen neu veröffentlicht. Im Anschluss dazu wird in 2017 der überarbeitete Normentwurf zur aktiven Thermografie veröffentlicht. Mit der Bearbeitung einer europäischen Norm zur Laserthermografie wurde begonnen. Auf nationaler Ebene werden zur Zeit Normen zu den verschiedenen Anregungstechniken erarbeitet. Anfang 2017 wurde der Normentwurf zur Impuls-Thermografie mit optischer Anregung veröffentlicht. Geplant sind weiterhin Entwurfsveröffentlichungen zur induktiv angeregten Thermografie sowie zur Lock-in-Thermografie mit optischer Anregung. Parallel dazu wurde die Überarbeitung der Norm zur Thermografischen Prüfung elektrischer Anlagen publiziert. Mit der Richtlinie VDI/VDE 3511 Blatt 4 bis 4.4 gibt es ein anerkanntes Regelwerk für die rückführbare Temperaturmessung und Kalibrierung von Strahlungsthermometern, die bisher für Thermografiekameras fehlte. In 2016 wurde daher die VDI/VDE Richtlinie 5585 Blatt 1 zur messtechnischen Charakterisierung von Thermografiekameras als Entwurf veröffentlicht. In Bearbeitung ist momentan Blatt 2 zur Kalibrierung von Thermografiekameras mit dem Ziel, auch für Thermografiekameras anerkannte Regeln zur rückführbaren Temperaturmessung zu erstellen. Im Beitrag werden die Anwendungsbereiche dieser Normen und Richtlinien vorgestellt und neue zukünftige Anwendungsbereiche in der Fertigung und Instandhaltung diskutiert. T2 - Thermografie-Kolloquium 2017 CY - Berlin, Germany DA - 28.9.2017 KW - Zerstörungsfreie Prüfung KW - Aktive Thermografie KW - Normung PY - 2017 AN - OPUS4-42396 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -