TY - JOUR A1 - Hempel, M. A1 - Tomm, J.W. A1 - Ziegler, Mathias A1 - Elsaesser, T. A1 - Michel, N. A1 - Krakowski, M. T1 - Catastrophic optical damage at front and rear facets of diode lasers N2 - Single-pulse tests of the catastrophic optical damage (COD) are performed for three batches of diode lasers with different gain-regions. The tests involve in situ inspection of front, rear, and side of the devices by a thermocamera. Devices with an Al-containing gain-region show COD at the front facet, as expected for strong facet heating via surface recombination and reabsorption of laser light. In contrast, Al-free devices with low surface recombination rates tend to fail at the rear facet, pointing to a different heating scenario. The high carrier density at the rear facet favors heating and COD via Auger recombination processes. KW - Thermography KW - Catastrophic optical damage KW - High power diode lasers KW - Destructive testing KW - Non-destructive testing KW - Auger effect KW - Carrier density KW - Heating KW - Laser beam effects KW - Optical testing KW - Semiconductor lasers KW - Surface recombination PY - 2010 DO - https://doi.org/10.1063/1.3524235 SN - 0003-6951 SN - 1077-3118 VL - 97 IS - 23 SP - 231101-1 - 231101-3 PB - American Institute of Physics CY - Melville, NY AN - OPUS4-22763 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Myrach, Philipp A1 - Jonietz, Florian A1 - Meinel, Dietmar A1 - Suwala, Hubert A1 - Ziegler, Mathias T1 - Calibration of thermographic spot weld testing with X-ray computed tomography N2 - The paper presents an attempt for the calibration of an active thermography method that is suitable for the non-destructive evaluation of spot welds. Nowadays, the quality of spot welds is commonly characterised by the application of random chisel tests, which are time consuming, expensive and destructive. Recently a non-destructive testing method by means of active thermography was proposed that relies on the fact that the mechanical connection formed by the spot weld also serves as a thermal bridge between the two steel sheets joined in the welding process. It is shown in this paper that this thermal bridge can be thermographically characterised by extracting a measure for the spot weld diameter and hence the quality of the spot weld. The determination of the absolute value of the diameter hereby relies on a calibration of the testing system, which is performed by means of X-ray computed tomography in this study. The experiments were carried out using different experimental approaches, namely transmission as well as reflection geometry wSetup in reflectionith laser illumination. A comprehensive evaluation of samples produced using different welding currents, hence different quality, was carried out in order to validate the thermographic results. KW - Thermography KW - Spot welds KW - Spot welding KW - Computed thomography KW - Non-destructive testing PY - 2017 DO - https://doi.org/10.1080/17686733.2017.1281554 SN - 1768-6733 SN - 2116-7176 VL - 14 IS - 1 SP - 122 EP - 131 PB - Taylor & Francis CY - London AN - OPUS4-40180 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Burgholzer, P. A1 - Berer, T. A1 - Ziegler, Mathias A1 - Thiel, Erik A1 - Ahmadi, Samim A1 - Gruber, J. A1 - Mayr, G. A1 - Hendorfer, G. T1 - Blind structured illumination as excitation for super-resolution photothermal radiometry N2 - Using an infrared camera for radiometric imaging allows the contactless temperature measurement of multiple surface pixels simultaneously. From the measured surface data, a sub-surface structure, embedded inside a sample or tissue, can be reconstructed and imaged when heated by an excitation light pulse. The main drawback in radiometric imaging is the degradation of the spatial resolution with increasing depth, which results in blurred images for deeper lying structures. We circumvent this degradation with blind structured illumination, combined with a non-linear joint sparsity reconstruction algorithm. The ground-breaking concept of super-resolution can be transferred from optics to thermographic imaging. T2 - Conference QIRT 2018 CY - Berlin, Germany DA - 25.06.2018 KW - Thermography KW - Laser thermography KW - Super resolution PY - 2018 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-454506 SN - 978-3-940283-94-8 DO - https://doi.org/10.1080/17686733.2019.1655247 SP - We.3.A.2, 1 EP - 7 AN - OPUS4-45450 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Burgholzer, P. A1 - Berer, T. A1 - Ziegler, Mathias A1 - Thiel, Erik A1 - Ahmadi, Samim A1 - Gruber, J. A1 - Mayr, G. A1 - Hendorfer, G. T1 - Blind structured illumination as excitation for super-resolution photothermal radiometry N2 - Photothermal radiometry with an infrared camera allows the contactless temperature measurement of multiple surface pixels simultaneously. A short light pulse heats the sample. The heat propagates through the sample by diffusion and the corresponding temperature evolution is measured at the sample’s surface by an infrared camera. The main drawback in radiometric imaging is the loss of the spatial resolution with increasing depth due to heat diffusion, which results in blurred images for deeper lying structures. We circumvent this information loss due to the diffusion process by using blind structured illumination, combined with a non-linear joint sparsity reconstruction algorithm. The structured illumination is realized by parallel laser lines from a vertical-cavity surface-emitting laser (VCSEL) array controlled by a random binary pattern generator. By using 150 different patterns of structured illumination and our iterative joint sparsity algorithm, it was possible to resolve 1 mm thick lines at a distance down to 0.5 mm, which results in a resolution enhancement of approximately a factor of four compared to the resolution of 5.9 mm for homogenous illuminated thermographic reconstruction. KW - Super-resolution imaging KW - Thermography KW - Blind structured illumination KW - VCSEL array PY - 2019 DO - https://doi.org/10.1080/17686733.2019.1655247 SN - 1768-6733 VL - 17 IS - 4 SP - 268 EP - 278 PB - Taylor & Francis Group CY - Milton, UK AN - OPUS4-49122 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Yagdjian, H. A1 - Lecompagnon, Julien A1 - Hirsch, Philipp Daniel A1 - Ziegler, Mathias A1 - Gurka, M. T1 - Application of the thermal shock response spectrum (TSRS) methodology to various forms of heat sources by pulse thermography and comparison by using a rotating line scan contour search algorithm N2 - In this paper, we propose a novel contour search algorithm (CSA) for image processing. Its efficacy is evaluated through a comparative analysis with established techniques such as Canny Edge and Snakes: Active contour models, utilizing infrared thermography (IRT) images. Based on the new CSA, we investigate the influence of different pulse shapes on the IRT post-processing methodology, particularly focusing on the thermal shock response spectrum (TSRS), using two different heat sources: xenon flash lamps and a laser. Moreover, this allows for a more precise quantitative comparison of the TSRS with existing IRT post-processing techniques, including pulse phase thermography and thermal signal reconstruction, concerning the detection of defects in composite materials, particularly in carbon fiber-reinforced polymer. A quantitative comparison was performed using the Tanimoto criterion and signal-to-noise ratio. A more detailed analysis is conducted to identify inherent limitations and potential benefits of the new TSRS methodology. We further investigate and experimentally confirm our previous finding on the qualitative correlation between the one-dimensional thermal N-layer model and test data from the TSRS optimization process for defect determination. This correlation can eliminate the time-consuming optimization step, making TSRS a more attractive alternative to common IRT methods and enhancing the quantitative description of defects. KW - Thermography KW - Non-destructive testing KW - NDT KW - Defect identification KW - Laser KW - Contour search PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-615056 DO - https://doi.org/10.1063/5.0232015 SN - 1089-7550 VL - 136 IS - 175101 SP - 1 EP - 20 PB - AIP Publishing AN - OPUS4-61505 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -