TY - JOUR A1 - Reiche, I. A1 - Muller, K. A1 - Alberic, M. A1 - Scharf, O. A1 - Wahning, A. A1 - Bjeoumikhov, A. A1 - Radtke, Martin A1 - Simon, R. T1 - Discovering vanished paints and naturally formed gold nanoparticles on 2800 years old Phoenician ivories using SR-FF-microXRF with the color X-ray camera N2 - Phoenician ivory objects (8th century B.C., Syria) from the collections of the Badisches Landesmuseum, Karlsruhe, Germany, have been studied with full field X-ray fluorescence microimaging, using synchrotron radiation (SR-FF-microXRF). The innovative Color X-ray Camera (CXC), a full-field detection device (SLcam), was used at the X-ray fluorescence beamline of the ANKA synchrotron facility (ANKA-FLUO, KIT, Karlsruhe, Germany) to noninvasively study trace metal distributions at the surface of the archeological ivory objects. The outstanding strength of the imaging technique with the CXC is the capability to record the full XRF spectrum with a spatial resolution of 48 µm on a zone of a size of 11.9 × 12.3 mm² (264 × 264 pixels). For each analyzed region, 69696 spectra were simultaneously recorded. The principal elements detected are P, Ca, and Sr, coming from the ivory material itself; Cu, characteristic of pigments; Fe and Pb, representing sediments or pigments; Mn, revealing deposited soil minerals; Ti, indicating restoration processes or correlated with Fe sediment traces; and Au, linked to a former gilding. This provides essential information for the assessment of the original appearance of the ivory carvings. The determined elemental maps specific of possible pigments are superimposed on one another to visualize their respective distributions and reconstruct the original polychromy and gilding. Reliable hypotheses for the reconstruction of the original polychromy of the carved ivories are postulated on this basis. KW - SR-FF-microXRF KW - Elemental imaging KW - Ivory KW - Paints KW - Au NPs KW - Egyptian blue KW - Fe PY - 2013 DO - https://doi.org/10.1021/ac4006167 SN - 0003-2700 SN - 1520-6882 VL - 85 IS - 12 SP - 5857 EP - 5866 PB - American Chemical Society CY - Washington, DC AN - OPUS4-30222 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Rauwolf, M. A1 - Turyanskaya, A. A1 - Roschger, A. A1 - Prost, J. A1 - Simon, R. A1 - Scharf, O. A1 - Radtke, Martin A1 - Schoonjans, Tom A1 - de Oliveira Guilherme Buzanich, Ana A1 - Klaushofer, K. A1 - Wobrauschek, P. A1 - Hofstaetter, J. G. A1 - Roschger, P. A1 - Streli, C. T1 - Synchrotron radiation micro X-ray fluorescence spectroscopy of thin structures in bone samples: comparison of confocal and color X-ray camera setups N2 - In the quest for finding the ideal synchrotron-radiation-induced imaging method for the investigation of trace element distributions in human bone samples, experiments were performed using both a scanning confocal synchrotron radiation micro X-ray fluorescence (SR-mXRF) (FLUO beamline at ANKA) setup and a full-field color X-ray camera (BAMline at BESSY-II) setup. As zinc is a trace element of special interest in bone, the setups were optimized for its detection. The setups were compared with respect to count rate, required measurement time and spatial resolution. It was demonstrated that the ideal method depends on the element of interest. Although for Ca (a major constituent of the bone with a low energy of 3.69 keV for its K alpha XRF line) the color X-ray camera provided a higher resolution in the plane, for Zn (a trace element in bone) only the confocal SR-µXRF setup was able to sufficiently image the distribution. KW - Synchrotron KW - BAMline KW - BESSY KW - XRF KW - X-ray Color Camera PY - 2017 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-391944 DO - https://doi.org/10.1107/S1600577516017057 SN - 1600-5775 VL - 24 SP - 307 EP - 311 PB - International Union of Crystallography AN - OPUS4-39194 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Reiche, I. A1 - Berger, Achim A1 - Duval, A. A1 - Guicharnaud, H. A1 - Merchel, Silke A1 - Radtke, Martin A1 - Schäfer, D. A1 - Simon, R. T1 - SY-XRF study of Hans Baldung Grien silverpoint drawings and the silver stylus from the 'Karlsruhe sketchbook' N2 - We performed spatially resolved synchrotron-induced x-ray fluorescence analyses (SY-XRF) of five silverpoint drawings from the famous `Karlsruhe sketchbook´ and a silverpoint, which is assumed to be an original one used by the Renaissance artist Hans Baldung Grien (1484-1545) himself. The silverpoint, one out of a very small number of ancient styli conserved nowadays, is fixed on the so-called `Karlsruhe sketchbook´. Measurements were executed at the FLUO-TOPO beamline at the electron storage ring ANKA. It has been shown, that SY-XRF at this beamline is nondestructive and sensitive enough for the analysis of minor and major elements in the silver strokes. This study provides new insights into this graphical technique and ancient drawing instruments: results are that three drawings have been created with a common type of silverpoint containing about (10.4 ± 0.7) wt% of Cu. In all the cases, Hg at a 10% level by weight was identified in the strokes. Presence of Hg is not due to the original silver alloy, but is a result of a general alteration phenomenon of silverpoint drawings. This fact is confirmed by the analysis of the original silverpoint, which contains only small traces of Hg. The result for the copper content of the silverpoint (10.4 ± 1.7) wt% is in good agreement with that of these three drawings. It is supposable that the silverpoint found attached today served for the creation of the corresponding drawings. Moreover, the graphical technique of Baldung is found to be continual over three decades. Only one very late drawing dated to 1543 was probably realized with another silverpoint, containing about 3 wt% of Cu. This difference in the chemical composition of drawings from the late period might be used as a more precise dating indicator of Baldung drawings that are not clearly attributed to a certain period. KW - Synchrotron KW - XRF analysis KW - Drawings KW - Silver stylus PY - 2007 DO - https://doi.org/10.1002/xrs.963 SN - 0049-8246 VL - 36 IS - 3 SP - 173 EP - 177 PB - Wiley CY - Chichester AN - OPUS4-16150 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Vasilescu, A. A1 - Constantinescu, B. A1 - Bugoi, R. A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Simon, R. ED - Denecke, M. ED - Walker, C. T1 - Gold provenance studies for Romanian archaeological objects using micro-SR-XRF N2 - Studies by Synchrotron Radiation-X-Ray Fluorescence (SR-XRF) for the search of the presence of trace elements like Sb, Sn, Te and Pb in archaeological metallic objects found on the territory of Romania-old coins and Bronze Age jewelry, aimed to determine the provenance of the gold used in their manufacture. The results are compared with the detailed elemental composition of alluvial or primary gold samples, obtained by the same technique. This work attempted to establish the origin of the gold used for the mint of two different types of koson coins. We found that the kosons with monogram are made of refined gold, while the one used for the kosons without monogram is mainly alluvial. The gold used in the manufacture of the Calarasi Vulchitrun-type disk and the Tauteu hair ring is also of alluvial origin. T2 - 20th International congress on X-ray optics and microanalysis CY - Karlsruhe, Germany DA - 2009-09-14 KW - Provenance KW - Gold KW - SR-XRF KW - Trace elements PY - 2010 UR - http://link.aip.org/link/?APCPCS/1221/139/1 SN - 978-0-7354-0764-0 DO - https://doi.org/10.1063/1.3399240 SN - 0094-243X SP - 139 EP - 143 PB - American Institute of Physics AN - OPUS4-21182 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Berger, Achim A1 - Calligaro, T. A1 - Duval, A. A1 - Görner, Wolf A1 - Guerra, M.-F. A1 - Merchel, Silke A1 - Radtke, Martin A1 - Reiche, I. A1 - Riesemeier, Heinrich A1 - Roth, M. T1 - Study of Ag and Au based historical and archaeological objects by high energy Sy-XRF KW - Synchrotron KW - XRF analysis KW - Drawings KW - Archaeometry KW - Gold KW - Röntgenfluoreszenzanalyse KW - RFA KW - Zeichnungen KW - Archäometrie KW - Albrecht Dürer KW - gold PY - 2004 UR - http://www.helmholtz-berlin.de/media/media/oea/web/pr_webseite/druckschriften/berichte/bessy/annualreport2003.pdf#page=544 SN - 0179-4159 SP - 544 EP - 546 PB - Berliner Elektronenspeicherring-Gesellschaft für Synchrotronstrahlung CY - Berlin AN - OPUS4-3507 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Nowak, S.H. A1 - Bjeoumikhov, A. A1 - Von Borany, J. A1 - Buchriegler, J. A1 - Munnik, F. A1 - Petric, M. A1 - Radtke, Martin A1 - Renno, A.D. A1 - Reinholz, Uwe A1 - Scharf, O. A1 - Wedell, R. T1 - Sub-pixel resolution with a color X-ray camera N2 - The color X-ray camera SLcam® is a full-field, single photon detector providing scanning-free, energy and spatially resolved X-ray imaging. Spatial resolution is achieved with the use of polycapillary optics guiding X-ray photons from small regions on a sample to distinct energy dispersive pixels on a charged-coupled device detector. Applying sub-pixel resolution, signals from individual capillary channels can be distinguished. Therefore, the SLcam® spatial resolution, which is normally limited to the pixel size of the charge-coupled device, can be improved to the size of individual polycapillary channels. In this work a new approach to a sub-pixel resolution algorithm comprising photon events also from the pixel centers is proposed. The details of the employed numerical method and several sub-pixel resolution examples are presented and discussed. KW - Color X-ray camera KW - Sub pixel analysis PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-334948 DO - https://doi.org/10.1039/c5ja00028a SN - 0267-9477 SN - 1364-5544 SP - 1890 EP - 1897 PB - Royal Society of Chemistry CY - London AN - OPUS4-33494 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Reiche, I. A1 - Berger, Achim A1 - Duval, A. A1 - Görner, Wolf A1 - Guicharnaud, H. A1 - Merchel, Silke A1 - Radtke, Martin A1 - Riederer, J. A1 - Riesemeier, Heinrich A1 - Roth, M. ED - Röhrs, S. T1 - Auf den Spuren Albrecht Dürers - Zerstörungsfreie Untersuchung von Silberstiftzeichnungen mittels Mikro-PIXE und Synchrotron-induzierter Mikro-RFA T2 - Jahrestagung 2003 im Ethnologischen Museum Berlin-Dahlem CY - Berlin, Deutschland DA - 2003-03-12 PY - 2003 SN - 3-00-014223-1 SN - 0949-4057 SP - 118 EP - 120 CY - [Frankfurt am Main] AN - OPUS4-2356 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Reiche, I. A1 - Berger, Achim A1 - Duval, A. A1 - Görner, Wolf A1 - Guicharnaud, H. A1 - Merchel, Silke A1 - Radtke, Martin A1 - Riederer, J. A1 - Riesemeier, Heinrich A1 - Roth, M. ED - Marabelli, M. ED - Tabaso, M. T1 - Spatially resolved SR-XRF analyses of complex drawings of the Holbein family T2 - 8th International Conference on "Non-Destructive Investigations and Microanalysis for the Diagnostics and Conservation of the Cultural and Environmental Heritage" CY - Lecce, Italy DA - 2005-05-15 KW - X-ray spectrometry KW - XRF KW - Röntgenfluoreszenzanalyse KW - RFA KW - Silverpoint drawing KW - Silberstiftzeichnung PY - 2005 SP - 7 pages PB - Italian Society of Non Destructive Testing CY - Lecce AN - OPUS4-7677 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Merchel, Silke A1 - Berger, Achim A1 - Görner, Wolf A1 - Radtke, Martin A1 - Riesemeier, Heinrich A1 - Reiche, I. A1 - Riederer, J. A1 - Duval, A. A1 - Guicharnaud, H. T1 - Non-Destructive Investigations of Dürer's Silver Point Drawings by Pixe and SY-XRF T2 - 7th International Conference on Non-destructive testing and Microanalysis for the Diagnostics and Conservation of the Cultural and Environmental Heritage ; art 2002 CY - Antwerp, Belgium DA - 2002-06-02 PY - 2002 UR - http://srs.dl.ac.uk/arch/publications/reiche/reiche_fullcorr.pdf SP - 82 AN - OPUS4-1400 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Reiche, I. A1 - Berger, Achim A1 - Duval, A. A1 - Görner, Wolf A1 - Guicharnaud, H. A1 - Merchel, Silke A1 - Radtke, Martin A1 - Riederer, J. A1 - Riesemeier, Heinrich A1 - Roth, M. ED - Denker, A. ED - Adriaens, A. ED - Dowsett, M. ED - Giumlia-Mair, A. T1 - Synchrotron radiation and protons on the traces of famous artists - Non-destructive analyses of silverpoint drawings by Albrecht Dürer KW - X-ray spectrometry KW - XRF KW - Röntgenfluoreszenzanalyse KW - RFA KW - Silverpoint drawing KW - Silberstiftzeichnung PY - 2006 SN - 3-8167-7178-5 SP - 91 EP - 101 PB - Fraunhofer-IRB-Verl. CY - Stuttgart AN - OPUS4-14190 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Reiche, I. A1 - Berger, Achim A1 - Duval, A. A1 - Görner, Wolf A1 - Guicharnaud, H. A1 - Merchel, Silke A1 - Radtke, Martin A1 - Riederer, J. A1 - Riesemeier, Heinrich T1 - Traces of Albrecht Dürer: Non-destructive analyses of Renaissance silverpoint drawings KW - Nuclear industry KW - Nuclear medicine PY - 2004 SN - 92-0-114703-1 SN - 0074-1876 IS - 1181 SP - 138 EP - 142 PB - IAEA CY - Vienna AN - OPUS4-5548 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Reiche, I. A1 - Radtke, Martin A1 - Berger, Achim A1 - Görner, Wolf A1 - Ketelsen, T. A1 - Merchel, Silke A1 - Riederer, J. A1 - Riesemeier, Heinrich A1 - Roth, M. T1 - Spatially resolved synchrotron-induced X-ray fluorescence analyses of metal point drawings and their mysterious inscriptions N2 - Synchrotron-induced X-ray fluorescence (Sy-XRF) analysis was used to study the chemical composition of precious Renaissance silverpoint drawings. Drawings by famous artists such as Albrecht Dürer (1471–1528) and Jan van Eyck (approximately 1395–1441) must be investigated non-destructively. Moreover, extremely sensitive synchrotron- or accelerator-based techniques are needed since only small quantities of silver are deposited on the paper. New criteria for attributing these works to a particular artist could be established based on the analysis of the chemical composition of the metal points used. We illustrate how analysis can give new art historical information by means of two case studies. Two particular drawings, one of Albrecht Dürer, showing a profile portrait of his closest friend, “Willibald Pirckheimer” (1503), and a second one attributed to Jan van Eyck, showing a “Portrait of an elderly man”, often named “Niccolò Albergati”, are the object of intense art historical controversy. Both drawings show inscriptions next to the figures. Analyses by Sy-XRF could reveal the same kind of silverpoint for the Pirckheimer portrait and its mysterious Greek inscription, contrary to the drawing by Van Eyck where at least three different metal points were applied. Two different types of silver marks were found in this portrait. Silver containing gold marks were detected in the inscriptions and over-subscriptions. This is the first evidence of the use of gold points for metal point drawings in the Middle Ages. KW - Sy-XRF analysis KW - Drawing KW - Metal point KW - Albrecht Dürer KW - Jan van Eyck KW - Renaissance PY - 2004 DO - https://doi.org/10.1016/j.sab.2004.07.023 SN - 0584-8547 SN - 0038-6987 VL - 59 IS - 10-11 SP - 1657 EP - 1662 PB - Elsevier CY - Amsterdam AN - OPUS4-4575 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Reiche, I. A1 - Berger, Achim A1 - Görner, Wolf A1 - Merchel, Silke A1 - Radtke, Martin A1 - Riederer, J. A1 - Riesemeier, Heinrich A1 - Roth, M. T1 - Following the traces of Albrecht Dürer: analysis of silverpoint drawings by spatially resolved synchrotron-induced X-ray fluorescence analysis N2 - Spatially resolved X-ray fluorescence analysis using synchrotron radiation (SR-XRF) at the wavelength shifter beamline, BAMline, at BESSY was used to investigate Renaissance silverpoint drawings as it is extremely sensitive, non-destructive and can be carried out in air using an excitation spot in the hundred micrometer range. This paper deals with first results of the study of silverpoint drawings of Albrecht Dürer (1471–1528) belonging to the sketchbook that Albrecht Dürer used during a travel to the Netherlands in 1520/21. These results are compared to a PIXE study performed on drawings from the same sketchbook. The minor element composition of the silverpoint used for the drawings in the sketchbook was (10.6 ± 3.5) wt.% of Cu and traces of Zn. Mercury was found in the marks but does not belong to the initial composition of the silverpoint as it is attributed to an alteration phenomenon. One drawing of the sketchbook represents an exception. It consists of silver marks containing an additional minor element, Zn, in the marks and was, therefore, created with another silverpoint, probably at a different time than the other drawings. KW - Synchrotron KW - SR-XRF analysis KW - Drawing KW - Silverpoint KW - Albrecht Dürer PY - 2004 DO - https://doi.org/10.1016/j.nimb.2004.03.081 SN - 0168-583X SN - 1872-9584 VL - 226 IS - 1-2 SP - 83 EP - 91 PB - Elsevier CY - Amsterdam AN - OPUS4-4574 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Reiche, I. A1 - Berger, Achim A1 - Bevers, H. A1 - Dupuis, G. A1 - Duval, A. A1 - Görner, Wolf A1 - Guicharnaud, H. A1 - Merchel, Silke A1 - Radtke, Martin A1 - Riederer, J. A1 - Riesemeier, Heinrich A1 - Roth, M. T1 - Spatially resolved SR-XRF analyses of complex drawings by the Holbein family and silverpoint drawings by Rembrandt KW - X-ray spectrometry KW - XRF KW - Röntgenfluoreszenzanalyse KW - RFA KW - Silverpoint drawing KW - Silberstiftzeichnung PY - 2005 UR - http://www.helmholtz-berlin.de/media/media/oea/web/pr_webseite/druckschriften/berichte/bessy/annualreport2004.pdf#page=491 SN - 0179-4159 SP - 491 EP - 493 PB - Berliner Elektronenspeicherring-Gesellschaft für Synchrotronstrahlung CY - Berlin AN - OPUS4-7380 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin A1 - Reiche, I. A1 - Berger, Achim A1 - Merchel, Silke A1 - Riesemeier, Heinrich A1 - Görner, Wolf A1 - Riederer, J. A1 - Roth, M. ED - Simionovici, A. T1 - BAMline meets Dürer and Van Eyck - Spatially resolved SR-XRF analyses of silver point drawings and their mysterious inscriptions T2 - 17th International Conference on X-Ray Optics and Microanalysis ; 17th ICXOM CY - Chamonix, France DA - 2003-09-22 PY - 2003 N1 - Serientitel: Spectrochimica acta : Part B, Atomic spectroscopy – Series title: Spectrochimica acta : Part B, Atomic spectroscopy IS - 59.2004,10/11 SP - 48 PB - Elsevier CY - Amsterdam AN - OPUS4-2690 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Reiche, I. A1 - Berger, Achim A1 - Duval, A. A1 - Görner, Wolf A1 - Merchel, Silke A1 - Radtke, Martin A1 - Riederer, J. A1 - Riesemeier, Heinrich T1 - Metallstiftzeichnungen Albrecht Dürers KW - Synchrotron KW - XRF analysis KW - Drawings KW - Archaeometry KW - Röntgenfluoreszenzanalyse (RFA) KW - Zeichnungen KW - Archäometrie KW - Albrecht Dürer PY - 2004 SN - 1563-2628 VL - 5 IS - 2 SP - 30 EP - 38 PB - Foto Text Verl. CY - Stuttgart AN - OPUS4-3570 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Lutz, C. A1 - Breuckmann, M. A1 - Hampel, S. A1 - Kreyenschmidt, M. A1 - Ke, X. A1 - Beuermann, S. A1 - Schafner, K. A1 - Turek, T. A1 - Kunz, U. A1 - de Oliveira Guilherme Buzanich, Ana A1 - Radtke, Martin A1 - Fittschen, U. E. A. T1 - Characterization of Dimeric Vanadium Uptake and Species in Nafion™ and Novel Membranes from Vanadium Redox Flow Batteries Electrolytes N2 - A core component of energy storage systems like vanadium redox flow batteries (VRFB) is the polymer electrolyte membrane (PEM). In this work, the frequently used perfluorosulfonic-acid (PFSA) membrane Nafion™ 117 and a novel poly (vinylidene difluoride) (PVDF)-based Membrane are investigated. A well-known problem in VRFBs is the vanadium permeation through the membrane. The consequence of this so-called vanadium crossover is a severe loss of capacity. For a better understanding of vanadium transport in membranes, the uptake of vanadium ions from electrolytes containing Vdimer(IV–V) and for comparison also V(II), V(III), V(IV), and V(V) by both membranes was studied. UV/VIS spectroscopy, X-ray absorption near edge structure spectroscopy (XANES), total reflection X-ray fluorescence spectroscopy (TXRF), inductively coupled plasma optical emission spectrometry (ICP-OES), and micro X-ray fluorescence spectroscopy (microXRF) were used to determine the vanadium concentrations and the species inside the membrane. The results strongly support that Vdimer(IV–V), a dimer formed from V(IV) and V(V), enters the nanoscopic water-body of Nafion™ 117 as such. This is interesting, because as of now, only the individual ions V(IV) and V(V) were considered to be transported through the membrane. Additionally, it was found that the Vdimer(IV–V) dimer partly dissociates to the individual ions in the novel PVDF-based membrane. The Vdimer(IV–V) dimer concentration in Nafion™ was determined and compared to those of the other species. After three days of equilibration time, the concentration of the dimer is the lowest compared to the monomeric vanadium species. The concentration of vanadium in terms of the relative uptake λ = n(V)/n(SO3 ) are as follows: V(II) [λ = 0.155] > V(III) [λ = 0.137] > V(IV) [λ = 0.124] > V(V) [λ = 0.053] > Vdimer(IV–V) [λ = 0.039]. The results show that the Vdimer(IV–V) dimer Needs to be considered in addition to the other monomeric species to properly describe the transport of vanadium through Nafion™ in VRFBs. KW - MicroXRF KW - VRFB KW - PVDF-based membrane KW - UV/VIS KW - XANES KW - TXRF KW - ICP-OES PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-530676 DO - https://doi.org/10.3390/membranes11080576 VL - 11 IS - 8 SP - 576 PB - MDPI AN - OPUS4-53067 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Guerra, M. F. A1 - Fischer, M. A1 - Radtke, Martin A1 - Reinholz, Uwe T1 - Inca figurines from the Ethnologisches Museum in Berlin: an analytical study of some typical and atypical productions N2 - Fourteen hollow and one cast anthropomorphic and zoomorphic figurines produced in Incan times for ritual offerings from the Ethnologisches Museum in Berlin were selected to investigate the technologies and alloys used for their fabrication with portable optical microscopy and non-destructive XRF elemental analysis. This group of gold and silver figurines includes typical specimens of the Inca production, such as the four silver figurines from the Island Coati in Lake Titicaca and the two gold figurines from Pachacamac, as well as specimens that are seldom present in collections, which makes them atypical. In addition to the tall figurines with atypical hair or standing pose, one bicolour figurine half silver, half gold) and another with coloured inlays were included in this study for comparison. The large majority of the silver specimens are made from very high quality alloys and the gold figurines are made from alloys containing low copper contents and silver ranging from 30wt% to 52wt%. KW - Gold KW - pXRF KW - Inca PY - 2017 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-436015 DO - https://doi.org/10.4000/bifea.8232 SN - 0303-7495 VL - 46 IS - 1 SP - 221 EP - 251 PB - Institut Français d'Études Andines AN - OPUS4-43601 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Hahn, Oliver A1 - Denker, A. A1 - Merchel, S. A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Wolff, T. ED - Armbruster, B. ED - Eilbracht, H. ED - Hahn, Oliver ED - Heinrich-Tamaska, O. T1 - Zerstörungsfreie Analyse von Metallartefakten - Eine Fallstudie N2 - Die naturwissenschaftliche Analyse historischer Materialen ermöglicht die Beantwortung kulturhistorischer Fragestellungen, die mit kunsthistorischen oder archäologischen Ansätzen allein nicht zu leisten sind. In dieser Studie wurden sechs römische Münzen mit unterschiedlich stark ausgeprägten Korrosionsschichten an unbehandelten und polierten Stellen mit vier zerstörungsfreien analytischen Methoden untersucht: Hoch- und Niederenergie Protonen Induzierter Röntgenemission (HE-/PIXE), Synchrotronstrahlungsinduzierte-Röntgenfluoreszenzanalyse (SY-RFA) und Mikro-Röntgenfluoreszenzanalyse (Mikro-RFA) mit einem mobilen Gerät. Aufgrund von Unterschieden in den Messbedingungen und dem Einfluss der Patina-Schichten auf diese ergaben sich nur für wenige Elemente Übereinstimmungen in den quantitativen Daten. Zur Validierung zukünftiger Messkampagnen mit verschiedenen Methoden sind daher Vergleichstudien unerlässlich. N2 - Investigations of physical properties and chemical composition of ancient materials generate important data for answering culture-historical questions that cannot be solved by art historical and archaeological methods alone. This contribution reports on the analysis of six Roman coins, with different degrees of corrosion layers in parts that were not handled or polished, using four non-destructive methods: low-energy particle-induced X-ray emission (PIXE, 2 MeV), high-energy PIXE (68 MeV), μ-X-ray fluorescence (XRF) spectrometry with a portable device and synchrotron-radiation induced XRF. Because of differences in the conditions needed for measurement and the influence of the layers of patina on these measurements, there were few elements where the quantitative data were in agreement. Thus comparative analyses are essential to validate future measurement projects using different methods. KW - Zerstörungsfreie Prüfung KW - Protoneninduzierte Röntgenemission KW - Röntgenfluoreszenzanalyse KW - Non-destructive testing KW - Particle-induced X-ray emission KW - X-ray fluorescence analysis PY - 2016 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-385702 SN - 978-3-9816751-5-3 VL - Berlin studies of the ancient world, Band 35 SP - 117 EP - 137 PB - Edition Topoi CY - Berlin AN - OPUS4-38570 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hahn, Michael A1 - Buzanich, Günter A1 - Jähn, Katharina A1 - Reinholz, Uwe A1 - Radtke, Martin T1 - Analysis of cobalt deposition in periprosthetic bone specimens by high-resolution synchroton XRF in undecalcified histological thin sections N2 - Increasing numbers of implant revisions are a current clinical issue. Interactions of the endoprosthesis biomaterial with the body affect implantation time by wear processes, i.e. corrosion and abrasion. Previously, cobalt-chrome implants were shown to cause high levels of cobalt ions being deposited in the bone matrix. To determine a poten- tial functional role of these ions on bone homeostasis, we have developed a non-destructive dual analysis of highly sensitive elemental analysis by synchrotron XRF directly in undecalcified histological bone thin sections (4 μm). In this study, samples from 28 bone samples from hip endoprosthesis carriers (Surface Replacement Arthroplasty, metal-on-metal bearing) with an implant lifetime of 17–1750 days were used. Results were compared to age- matched control specimens. The histological analysis identified areas of bone cell activity and assigned them for XRF measurements. Co-Cr wear particles were identified in the bone marrow. In addition, Co ions were highly enriched in the mineralized bone matrix. The cobalt deposits were not homogeneously distributed, and areas of high signal intensity were identified. Co was distinctly deposited in the newly formed osteoid layer, but also within deeper layers of the bone matrix, whereby the Co concentration increased with higher degrees of bone matrix mineralization. In the current study, we determined cobalt accumulations in the bone matrix and showed for the first time via synchrotron XRF with a high spatial resolution direct on histological slides, that cobalt deposits in the mineralized bone matrix in a mineral-specific way that is dependent upon the implant lifetime. KW - Implant material KW - Cobalt deposition KW - Bone matrix KW - High-resolution synchrotron XRF KW - Histology PY - 2019 DO - https://doi.org/10.1016/j.mtla.2019.100290 SN - 2589-1529 VL - 6 SP - 100290, 1 EP - 8 PB - Elsevier Inc. CY - Amsterdam, Niederlande AN - OPUS4-47620 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Vogel, Christian A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Schäfers, F. A1 - Adam, Christian T1 - Chemical state of chromium, sulfur, and iron in sewage sludge ash based phosphorus fertilizers N2 - As an essential element of all life forms, phosphorus (P) is vital to the fertilizer industry. With decreasing quantity and quality of phosphate rock resources, recycling P-fertilizers from wastewater is of increasing interest. The P-fertilizer products of a recently developed thermochemical process for P recovery from sewage sludge ash (SSA) were investigated by chromium, sulfur, and iron K-edge X-ray near-edge structure (XANES) spectroscopy. This paper focuses the formation and prevention of toxic chromium(VI) and toxic sulfides during the thermochemical processes. Reducing conditions prevent the oxidation of chromium(III) in the SSA to toxic chromium(VI). Sulfides formed under the reducing conditions are nontoxic iron sulfides. Hematite (Fe2O3) present in the SSA is reduced to magnetite (Fe3O4). A gentle post-treatment at 400 °C under oxidizing conditions converts the iron sulfides into plant-available iron sulfates. This oxidative post-treatment does not form undesired chromium(VI) compounds. KW - X-ray absorption near-edge structure (XANES) spectroscopy KW - Phosphorus recovery KW - Sewage sludge ash KW - Chromium KW - Sulfur KW - Iron PY - 2015 DO - https://doi.org/10.1021/acssuschemeng.5b00678 SN - 2168-0485 VL - 3 IS - 10 SP - 2376 EP - 2380 PB - ACS Publ. CY - Washington, DC AN - OPUS4-34166 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - de Oliveira Guilherme Buzanich, Ana A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich A1 - Emmerling, Franziska ED - de Oliveira Guilherme Buzanich, Ana T1 - Time- and spatial-resolved X-ray absorption fine structure (XAFS) spectroscopy in a single-shot: new analytical possibilities for in situ material characterization N2 - A new concept that comprises both time- and lateral-resolved X-ray absorption fine-structure information simultaneously in a single shot is presented. This uncomplicated set-up was tested at the BAMline at BESSY-II (Berlin, Germany). The primary broadband beam was generated by a double multilayer monochromator. The transmitted beam through the sample is diffracted by a convexly bent Si (111) crystal, producing a divergent beam. This, in turn, is collected by either an energy-sensitive area detector, the so-called color X-ray camera, or by an area-sensitive detector based on a CCD camera, in θ-2θ geometry. The first tests were performed with thin metal foils and some iron oxide mixtures. A time resolution of lower than 1 s together with a spatial resolution in one dimension of at least 50 µm is achieved. KW - Single-shot XAFS KW - Time resolution KW - Spatial resolution KW - Divergent XAFS PY - 2016 DO - https://doi.org/10.1107/S1600577516003969 SN - 1600-5775 VL - 23 SP - 769 EP - 776 PB - International Union of Crystallography AN - OPUS4-38370 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Radtke, Martin A1 - Buzanich, Günter A1 - de Oliveira Guilherme Buzanich, Ana A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich A1 - Scharf, O. A1 - Scholz, Philipp A1 - Guerra, M.F. T1 - Double Dispersive X-Ray Fluorescence (D2XRF) based on an Energy Dispersive pnCCD detector for the detection of platinum in gold N2 - With the aim of improving limits of detection (LOD) of trace elements in a matrix with adjacent fluorescence energies, a simple double dispersive X-ray fluorescence detection system (D2XRF) was constructed to operate at the beamlines BAMline and the mySpot @ BESSY II. This system is based on the combination of a crystal analyzer with an energy resolving single photon counting pnCCD. Without further collimators, the efficient suppression of the background by the pnCCD and the good energy resolution of the crystal results in improved LOD. In first order reflections, an energy resolution of 13 eV for Cu Kα was reached, and an energy range of 1 keV was covered in one shot. This new system was applied to the detection of platinum (Pt) in gold leaves with a LOD of 0.9 mg/kg, which is the lowest attained by totally non-destructive methods nowadays. The presence of Pt in gilded objects from Abydos and Byzantine mosaics provides vital information, as it indicates the alluvial origin of the gold for these examples. KW - Platinum Wavelength dispersive D2XRF KW - Gold Synchrotron XRF PY - 2016 DO - https://doi.org/10.1016/j.microc.2015.10.039 VL - 125 SP - 56 EP - 61 PB - Elsevier Science CY - Amsterdam AN - OPUS4-35777 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Rakotondrajoa, Andrianiaina A1 - Buzanich, Günter A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich A1 - Vincze, L. A1 - Raboanary, R. T1 - Improvement of PLS regression-based XRF spectroscopy quantification using multiple step procedure and Monte Carlo simulation N2 - Partial least squares (PLS) regression-based methods have been proven to be a good alternative for quantification in X-ray fluorescence spectroscopy. These methods are fast and easy to use though giving satisfactory results under certain conditions. One of these conditions is the necessity of having a great number of spectra to build the model (training set). The choice of the constituent concentration range in the training set has a big influence on the accuracy of the model. Better accuracy is obtained if the model is built in relatively narrow regions containing (or close to) the real concentration value. In the present work, Monte Carlo (MC) simulated spectra are used to form the training set. The advantage to use MC generated training spectra is the unlimited availability of perfect standards. This paper aims to improve the accuracy of the method by introducing a multiple step procedure in order to build the PLS model using narrow concentration range close to (or containing) the real concentration values in the samples to be measured. This approach consists of an initial guess of the constituents' concentrations and a preliminary PLS model before building the final model. The prediction of ten MC simulated alloy standard samples containing Ti, Mn, Fe, Co, Cu, Zn, Sr, Zr, and Mo using this method allowed to have average relative prediction errors less than 5% for elements with narrow concentration ranges. KW - SR-microXRF KW - Quantification KW - PLS KW - Monte Carlo PY - 2013 DO - https://doi.org/10.1002/xrs.2479 SN - 0049-8246 VL - 42 IS - 4 SP - 183 EP - 188 PB - Wiley CY - Chichester AN - OPUS4-30225 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin A1 - Fittschen, U.E.A. A1 - Menzel, M. A1 - Scharf, O. A1 - Horntrich, C. A1 - Streli, C. A1 - Montoya, V. A1 - McIntosh, K. A1 - Havrilla, G.J. T1 - THE IDEAL SPECIMENT FOR TOTAL REFLECTION X-RAY FLUORESCENCE (TXRF) ANALYSIS: RESULTS FROM SIMULATIONS AND EXPERIMENTAL EVALUATION T2 - International Congress on X-Ray Optics and Microanalysis CY - Hamburg, Germany DA - 2013-09-02 PY - 2013 AN - OPUS4-29871 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Menzel, Michael A1 - Fittschen, U.E.A. A1 - Scharf, Oliver T1 - ABSORBTION OF THE PRIMARY BEAM IN SR-TXRF ANALYSIS: EXPERIMENTAL VISUALIZATION USING A COLOR X-RAY CAMERA T2 - International Congress on X-Ray Optics and Microanalysis CY - Hamburg, Germany DA - 2013-09-02 PY - 2013 AN - OPUS4-29898 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin T1 - Röntgenfluoreszenzanalyse mit Synchrotronstrahlung an der Bundesanstalt für Materialforschung und -prüfung (BAM), Berlin T2 - Seminar: "Strahlenphysikalische Anwendungen in Technik und Medizin" CY - Vienna, Austria DA - 2013-01-16 PY - 2013 AN - OPUS4-29861 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin A1 - Buzanich, Günter A1 - Fittschen, U.E.A A1 - Menzel, M. A1 - Scharf, Oliver A1 - Horntrich, C. A1 - Montoya, V. A1 - McIntosh, K. A1 - Havrilla, G.J. T1 - Evaluation of total reflection X-ray fluorescence (TXRF) analysis using a color X-ray camera (CXC) T2 - 15th International Conference on Total Reflection X-Ray Fluorescence Analysis and Related Methods (TXRF2013) CY - Osaka, Japan DA - 2013-09-23 PY - 2013 AN - OPUS4-29859 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Buzanich, Günter A1 - Fittschen, U.E.A. A1 - Menzel, M. A1 - Scharf, O. A1 - Horntrich, C. A1 - Streli, C. A1 - Montoya, V. A1 - Havrilla, G.J. A1 - McIntosh, K. T1 - THE IDEAL SPECIMENT FOR TOTAL REFLECTION X-RAY FLUORESCENCE (TKRF) ANALYSIS:RESULTS FROM SIMULATIONS AMD EXPERIMENTAL EVALUATION T2 - Fifth Joint BER II and BESSY II User Meeting CY - Berlin, Germany DA - 2013-12-04 PY - 2013 AN - OPUS4-29903 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin A1 - Stalinski, T. A1 - Püschel, F. A1 - Scharf, O. A1 - Arkadiev, V. A1 - Wedell, R. T1 - Adaptive Kanalreduktion eines hyperspektralen Bilddatensatzes kombiniert mit k-mean Clustering T2 - Workshop Farbbildverarbeitung - Wuppertal 2014 CY - Wuppertal DA - 2014-09-25 PY - 2014 AN - OPUS4-32365 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin A1 - Menzel, Michael A1 - Fittschen, U.E.A. A1 - Scharf, O. T1 - ABSOPTION OF THE PRIMARY BEAM IN SR-TXRF ANALYSIS: EXPERIMENTAL VISUALIZATION USING A COLOR X-RAY CAMERA T2 - Fifth Joint BER II User Meeting CY - Berlin, Germany DA - 2013-12-04 PY - 2013 AN - OPUS4-29901 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich A1 - Guerra, M. F. A1 - Reiche, I. T1 - Between the Eurasien steppes and China: provenancing the Xiongnu gold by IBA and SRXRF T2 - Fifth Joint BER II and BESSY II User Meeting CY - Berlin, Germany DA - 2013-12-04 PY - 2013 AN - OPUS4-29905 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin A1 - Buzanich, Günter A1 - Curado, Jessica A1 - Riesemeier, Heinrich A1 - Scharf, O. T1 - Slicing - A New Method For Non Destructive 3D Elemental Sensitive Characterization Of Materials T2 - Fifth Joint BER II and BESSY II User Meeting CY - Berlin, Germany DA - 2013-12-04 PY - 2013 AN - OPUS4-29904 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin A1 - Curado, Jessica A1 - Buzanich, Günter A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich A1 - Guttler, R.A.S. A1 - Rizzutto, M.A. T1 - u-SRXRF characterization of Brazilian emeralds T2 - Fifth Joint BER II and BESSY II User Meeting CY - Berlin, Germany DA - 2013-12-04 PY - 2013 AN - OPUS4-29902 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin A1 - Buzanich, Günter A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich A1 - Scharf, O. T1 - The Color X-Ray Camera: Imaging and Beyond T2 - ANKA/KNMF User Meeting 2013 CY - 76646 Bruchsal, Deutschland DA - 2013-09-26 PY - 2013 AN - OPUS4-29900 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin T1 - Röntgenfluoreszenzanalyse mit Synchrotronstrahlung an der Bundesanstalt für Materialforschung und -prüfung (BAM), Berlin T2 - Seminar "Strahlenphysikalische Anwendungen in Technik und Medizin" CY - Wien (Österreich) DA - 2014-01-14 PY - 2014 AN - OPUS4-32367 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin A1 - Buzanich, Günter A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich A1 - Curado, Jessica T1 - Slicing - A New Method For Non Destructive 3D Elemental Sensitive Characterization Of Materials T2 - Digital Speciman 2014 CY - Berlin DA - 2014-09-08 PY - 2014 AN - OPUS4-32368 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin T1 - Experiences with the Color X-Ray Camera at the BAMline T2 - X-ray Spectroscopy Detectors for Present and Future Synchrotron Storage rings: Opportunities for Horizon 2020 CY - Paris, Frankreich DA - 2015-03-16 PY - 2015 AN - OPUS4-34009 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin A1 - Buzanich, Günter A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich A1 - Scharf, O. T1 - Double Dispersive X-ray Fluorescence T2 - EXRS 2014 CY - Bologna (Italien) DA - 2014-06-15 PY - 2014 AN - OPUS4-32370 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich T1 - Analysis of ancient gold objects with SRXRF at the BAMline T2 - Technart 2015 CY - Catania, Italien DA - 2015-04-27 PY - 2015 AN - OPUS4-34007 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin T1 - Imaging with the Color X-ray Camera - Basics and Examples T2 - HZB Industry Workshop CY - Berlin DA - 2015-02-19 PY - 2015 AN - OPUS4-34023 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin T1 - News from the BAMline N2 - In this talk, the newest developments at the BAMline and examples of applications are presented. T2 - Seminar: STRAHLENPHYSIKALISCHE ANWENDUNGEN IN TECHNIK UND MEDIZIN CY - Vienna, Austria DA - 18.01.2017 KW - XANES KW - Synchrotron KW - XRF KW - BESSY PY - 2017 AN - OPUS4-42981 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin T1 - Von Ägypten bis Hiddensee – Analyse von Gold mit Synchrotronstrahlung - Update 2018 N2 - Gold ist eines der sieben schon im Altertum bekannten Metalle und wurde wg. seines Glanzes und seiner Seltenheit von alters her als Tauschmittel und zur Herstellung von Schmuck benutzt. Außerdem ist es einfach bearbeitbar und weitestgehend gegen chemische Einflüsse resistent. Die Untersuchungen von Gold mit synchrotronstrahlungsangeregter Röntgenfluoreszenzanalyse sind zerstörungsfrei und geben Auskunft über die in der untersuchten Probe vorhandenen chemischen Elemente. Bei den hier vorgestellten Untersuchungen an der BAMline stehen Fragestellungen wie Herkunft, Herstellungsverfahren und Zusammengehörigkeit von Goldfunden im Vordergrund. Die verschiedenen Fragestellungen werden an einer Reihe von Beispielen erläutert die vom Wikingerschatz aus Hiddensee über die Himmelsscheibe von Nebra bis hin zu Funden aus Ägypten langen. Zusätzlich werden die modernen Messmethoden vorgestellt, die am Synchrotron heutzutage zur Verfügung stehen. T2 - Vorlesung FU Berlin Einführung in die Archäometrie CY - Berlin, Germany DA - 01.11.2018 KW - Gold KW - Synchrotron KW - XRF KW - BAMline PY - 2018 AN - OPUS4-46451 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin T1 - Von der Antike in die Zukunft: Materialanalyse mit Synchrotronstrahlung N2 - Die Eigenschaften und die Verlässlichkeit von Materialien jeglicher Art sind seit jeher die Grundlagen der Technik einer Gesellschaft. Tiefgreifende Kenntnisse über sie sind deshalb eine Voraussetzung um neue Produkte zu entwickeln, Verlässlichkeit zu gewährleisten, oder aber auch, wie in der Archäometrie, Kenntnisse über die Vergangenheit zu gewinnen. Ein Schlüssel zum Verständnis ist das Wissen über die chemische Zusammensetzung und die Struktur von Materialien Die Analyse mit Synchrotronstrahlung bietet hierfür herausragende Werkzeuge an, die zerstörungsfrei und hochsensitiv sind. Mit Röntgenfluoreszenzanalyse kann die elementare Zusammensetzung in winzigen Proben bis auf μg/g bestimmt werden. Anwendungsbeispiele aus verschiedenen Themengebieten, aber besonders von archäologischen Fragestellungen wie z.B. dem Goldfund von Bernstorf werden im Vortrag vorgestellt. T2 - Berliner Industriegespräch CY - Berlin, Germany DA - 05.04.2017 KW - Gold KW - Synchrotron KW - XRF KW - BESSY KW - Archeometry KW - BAMline PY - 2017 AN - OPUS4-42979 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin T1 - Von Ägypten bis Hiddensee – Analyse von Gold mit Synchrotronstrahlung N2 - Gold ist eines der sieben schon im Altertum bekannten Metalle und wurde wg. seines Glanzes und seiner Seltenheit von alters her als Tauschmittel und zur Herstellung von Schmuck benutzt. Außerdem ist es einfach bearbeitbar und weitestgehend gegen chemische Einflüsse resistent. Die Untersuchungen von Gold mit synchrotronstrahlungsangeregter Röntgenfluoreszenzanalyse sind zerstörungsfrei und geben Auskunft über die in der untersuchten Probe vorhandenen chemischen Elemente. Bei den hier vorgestellten Untersuchungen an der BAMline stehen Fragestellungen wie Herkunft, Herstellungsverfahren und Zusammengehörigkeit von Goldfunden im Vordergrund. Die verschiedenen Fragestellungen werden an einer Reihe von Beispielen erläutert die vom Wikingerschatz aus Hiddensee über die Himmelsscheibe von Nebra bis hin zu Funden aus Ägypten langen. Zusätzlich werden die modernen Messmethoden vorgestellt, die am Synchrotron heutzutage zur Verfügung stehen. T2 - Vorlesung FU Berlin Einführung in die Archäometrie CY - Berlin, Germany DA - 04.11.2016 KW - Synchrotron KW - BAMline KW - Gold KW - XRF PY - 2016 AN - OPUS4-38810 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Gebhard, R. T1 - Synchrotron radiation–induced X-ray fluorescence (SRXRF) analyses of the Bernstorf Gold N2 - The gold finds from Bernstorf, in the Freising district of Bavaria, were discovered in 1998, in the area of a Bronze Age settlement. First analyses with X-ray fluorescence (XRF) revealed gold of an unusually high purity grade, which was explained by the use of cementation techniques. A newer analysis with laser ablation inductively coupled plasma mass spectrometry (LA–ICP–MS) indicated an even higher purity. The analytical results were the starting point of an ongoing discussion. In this study, we re-analysed 11 gold samples with Synchrotron radiation–induced X-ray fluorescence at the BAMline at BESSY. In a thorough analysis, different excitation and detection conditions were applied to confirm or disprove the previous results. It was shown that the purity of the gold from the specimen is higher than 99.9%. The main impurities are silver in a range between 20 and 200 μg/g and copper between 1 and 10 μg/g. The results are in very good agreement with the LA–ICP–MS measurements and provide basic information for discussions about provenance, processing techniques or considerations of authenticity. KW - Gold KW - Synchrotron KW - XRF KW - BESSY KW - Archeometry PY - 2017 DO - https://doi.org/10.1111/arcm.12294 SN - 0003-813X SN - 1475-4754 VL - 59 IS - 5 SP - 891 EP - 899 PB - Wiley AN - OPUS4-42540 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin T1 - Zur Röntgenfluoreszenzanalyse von Kulturgütern - Von Nebra bis Ägypten N2 - Im Vortag werden die Möglichkeiten der Synchrotronstrahlungsinduzierten Röntgenfluoreszenzanalayse (SRXRF) dargestellt. Insbesondere werden bei einer Reihe von Beispielen die Vorteile der SRXRF erläutert und der mögliche Einsatz eines portablen Messgeräts für die Analse von Glas diskutiert. T2 - Workshop: Ritter, Goethe, ihre Prismen und die Polarität CY - Jena, Germany DA - 19.05.2017 KW - Gold KW - Synchrotron KW - XRF KW - BESSY KW - Archeometry KW - BAMline PY - 2017 AN - OPUS4-42976 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin A1 - de Oliveira Guilherme Buzanich, Ana A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich A1 - Scharf, O. T1 - The Colour X-ray Camera – Basics and Applications of a 2D X-ray Detector N2 - The Color X-ray Camera CXC or SLcam® is an energy-resolving X-ray camera capable of energy- and space-resolved measurements. It consists of a high-speed CCD detector coupled to a polycapil-lary optic that conducts the X-ray photons from the probe to distinct pixels onto the detector. The camera is capable of fast acquisition of spatially and energy resolved fluorescence images. A dedicated software enables the acquisition and the online processing of the spectral data for all 69696 pixels, leading to a real-time visualization of the elements distribution in a sample. It was developed in a joint project with BAM, IFG Berlin and PN Sensors. In this contribution we will mainly discuss the use of the CXC at our beamline, the BAMline at BESSY II and imaging applications of the CXC from different areas, like biology and archaeometry. Additionally new developments for the use of the detector without optics, like wavelength dispersive detection or 1shot-XANES, will be presented. T2 - Seminar Strahlenphysikalische Anwendungen in Technik und Medizin CY - Wien, Austria DA - 20.01.2016 KW - Synchrotron KW - BAMline KW - XRF PY - 2016 AN - OPUS4-38811 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Lutz, C. A1 - Hampel, S. A1 - Ke, X. A1 - Beuermann, S. A1 - Turek, T. A1 - Kunz, U. A1 - de Oliveira Guilherme Buzanich, Ana A1 - Radtke, Martin A1 - Fittschen, U. T1 - Evidence for redox reactions during vanadium crossover inside the nanoscopic water-body of Nafion 117 using X-ray absorption near edge structure spectroscopy N2 - A major source of capacity fade of the common vanadium redox flow battery (VRFB) is the vanadium ion transport through the separator. However, different transport models disagree significantly in the diffusion coefficient for the different V species and the influence of different transport mechanisms. The underlying hypothesis of this work is that reactions inside the membrane are partly responsible for these discrepancies. Accordingly, it was investigated if redox reactions inside the nanoscopic water body of Nafion 117 can occur. X-ray absorption near edge structure spectroscopy (XANES) was used to distinguish between the different V species inside hydrated Nafion 117 and novel PVDF-based membranes. It was validated that the speciation of vanadium can be performed using the pre-edge peak energy and intensity. The experiments were performed as follows: strips of the membrane were exposed from one site to a V3+ solution (green) and from the other site to a VO2+ solution (yellow). The ions could diffuse into the membrane from both sides. A change of color of the membrane strip was observed. The blue color in the middle of the strip indicated that VO2+ was formed where V3+ and VO2+ got in contact. Using XANES this reaction inside Nafion was proven. KW - PVDF-Based membrane KW - VRFB KW - Vanadium speciation KW - XANES KW - Nafion 117 PY - 2020 DO - https://doi.org/10.1016/j.jpowsour.2020.229176 VL - 483 SP - 229176 PB - Elsevier B.V. AN - OPUS4-51719 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Aldrabee, A. A1 - Wriekat, A. A1 - Abu Saleem, K. A1 - Radtke, Martin T1 - Non-destructive SR-XRF analysis of ancient Mamluk-Ayyubid glazed pottery fragments from Karak Castle, Jordan N2 - Sixteen Ayyubid-Mamluk glazed pottery sherds were analyzed in order to identify and characterize the elemental composition to determine their provenance. The tested sherds were collected from the historical site of Karak Castle, southern Jordan. Chemical analysis for the sixteen samples has been carried out using Synchrotron Radiation X-ray Fluorescence Spectrometry (SR-XRF) Technique. Furthermore, the semiquantitative analysis of the elements Fe – Cu – Zn – Br – Rb – Sr – Y – Zr – Nb – Mo – Pd – Ag – Cd and Pb has been performed for the samples based on Principal Component Analysis (PCA) and hierarchical Cluster Analysis with Bray-Curtis in order to define grouping of different glazed pottery by obtaining information on their similarity and clustering. The results of chemical analysis provided persuasive evidence that the Karak Castle pottery sherds have at least three different sources of provenance. KW - BAMline KW - Karak Castle KW - Synchrotron KW - XRF PY - 2015 VL - 8 IS - 3 SP - 157 EP - 163 AN - OPUS4-43489 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -