TY - JOUR A1 - Strüder, L. A1 - Hartmann, R. A1 - Holl, P. A1 - Ihle, S. A1 - Huth, M. A1 - Schmidt, J. A1 - Tham, Ch. A1 - Kanngießer, B. A1 - Baumann, J. A1 - Renno, A. A1 - Grenzer, J. A1 - Radtke, Martin A1 - Abboud, A. A1 - Pietsch, U. A1 - Soltau, H. T1 - High Speed, High Resolution imaging spectrometers based on pnCCDs for XRF and XRD applications N2 - For many years pnCCDs have been well known as X-ray detectors for spectroscopic imaging in many fields of science: X-Ray Fluorescence analysis (XRF), X-ray Diffraction (XRD) with light sources in large accelerator facilities as well as with laboratory light sources or with X-rays from celestial sources in X-ray astronomy. A brief introduction in GEXRF (Grazing Emission XRF) measurements with a laboratory laser produced plasma source will be given, PIXE (Particle Induced X-ray Emission) measurements and D2XRF (Double Dispersive X-Ray Fluorescence) and Slicing experiments with pnCCDs coupled to polycapillary optics performed at the BESSY synchrotron will be shown. Energy-dispersive Laue diffraction with ultra-hard X-rays for the analysis of defects in metals will conclude the overview of spectroscopic X-ray imaging measurements in the field of structure and dynamics of matter. KW - PnCCD KW - Synchrotron KW - XRF PY - 2016 DO - https://doi.org/10.1017/S1431927616001355 VL - 22 IS - S3 SP - 100 EP - 101 AN - OPUS4-38884 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Zier, M. A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich A1 - Radtke, Martin A1 - Munnik, F. T1 - Accurate stopping power determination of 15N ions for hydrogen depth profiling by a combination of ion beams and synchrotron radiation N2 - Hydrogen analysis is of particular importance in thin film technology and it is often necessary to obtain a depth profile. The method with the best depth resolution is NRA using the 6385 keV resonance of the 1H(15N,αγ)12C nuclear reaction. The correct quantification of the depth and concentration scales in the measured hydrogen profiles relies on accurate stopping power values. We present a method to deduce these values from a combination of two techniques: NRA and X-ray reflectometry (XRR). This method is applied to the determination of the stopping power of ~6.4 MeV 15N ions in H-containing amorphous Si-layers (a-Si:H). Density-independent stopping powers at different H concentrations are determined by combining the results from NRA and XRR with an overall uncertainty of 3.3%, showing good agreement with SRIM values. This work shows exemplary the methodology for future evaluation of stopping powers for quality assurance in NRA. KW - Nuclear reaction analysis KW - Hydrogen depth profiling KW - Stopping cross section KW - Linear energy transfer KW - Synchrotron radiation KW - XRR PY - 2012 DO - https://doi.org/10.1016/j.nimb.2011.07.027 SN - 0168-583X SN - 1872-9584 VL - 273 SP - 18 EP - 21 PB - Elsevier B.V. CY - Amsterdam AN - OPUS4-25722 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Constantinescu, B. A1 - Bugoi, R. A1 - Cojocaru, V. A1 - Radtke, Martin A1 - Calligaro, T. A1 - Salomon, J. A1 - Pichon, L. A1 - Röhrs, S. A1 - Ceccato, D. A1 - Oberländer-Târnoveanu, E. T1 - Micro-SR-XRF and micro-PIXE studies for archaeological gold identification - The case of Carpathian (Transylvanian) gold and of Dacian bracelets N2 - Trace-elements are more significant for provenancing archaeological metallic artifacts than the main components. For gold, the most promising elements are platinum group elements (PGE), Sn, Te, Sb, Hg and Pb. Several small fragments of natural Transylvanian gold – placer and primary – were studied by using micro-PIXE technique at the Legnaro National Laboratory AN2000 microbeam facility, Italy and at the AGLAE accelerator, C2RMF, Paris, France and by using micro synchrotron radiation X-ray fluorescence (micro-SR-XRF) at BESSY synchrotron, Berlin, Germany. The goal of the study was to identify the trace-elements, especially Sn, Sb and Te. A spectacular application to five Dacian gold bracelets authentication is presented (Sn and Sb traces). KW - Micro-PIXE KW - Micro-SR-XRF KW - Gold KW - Dacian bracelets KW - Transylvania PY - 2008 DO - https://doi.org/10.1016/j.nimb.2008.03.054 SN - 0168-583X SN - 1872-9584 VL - 266 IS - 10 SP - 2325 EP - 2328 PB - Elsevier CY - Amsterdam AN - OPUS4-17736 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Denker, A. A1 - Hahn, Oliver A1 - Kanngießer, B. A1 - Malzer, W. A1 - Merchel, Silke A1 - Radtke, Martin A1 - Röhrs, S. A1 - Reiche, I. A1 - Stege, H. T1 - Chemie der Kunst - Zerstörungsfreie Analyse von Kunst- und Kulturgütern N2 - Naturwissenschaftliche Informationen, insbesondere die chemische Zusammensetzung der Objekte, können Hinweise auf die Hintergründe der Objektherstellung liefern, die der alleinigen kunsthistorischen Begutachtung verborgen blieben. Es können nicht nur Fragen nach dem Prozess, Zeitpunkt und Ort der Herstellung beantwortet werden. Die chemische Analyse gibt auch Hinweise auf Ereignisse und Veränderungen, die erst nach der Fertigstellung des Objektes erfolgten. So werden Alterungsphänomene oder historische Überarbeitungen und Restaurierungen aufgedeckt, aber auch Konservierungsstrategien zur Erhaltung der Kunstwerke unterstützt. Durch den technologischen Fortschritt im Bereich der röntgenanalytischen Methoden, die berührungsfrei, ohne Probennahme und ohne Schädigung für das Untersuchungsobjekt arbeiten, erschließen sich dem Analytiker erstmalig Möglichkeiten, auch sehr wertvolle und fragile Objekte zerstörungsfrei zu untersuchen. PY - 2003 DO - https://doi.org/10.1515/mt-2003-0003 SN - 0025-5300 VL - 45 IS - 11-12 SP - 485 EP - 503 PB - Carl Hanser Verlag CY - München AN - OPUS4-2745 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Wilde, L. A1 - Schneider, M. A1 - Herein, D. A1 - Riesemeier, Heinrich A1 - Radtke, Martin T1 - XAS measurements on vanadium based compounds at the BAMline PY - 2003 UR - http://www.helmholtz-berlin.de/media/media/oea/web/pr_webseite/druckschriften/berichte/bessy/annualreport2002.pdf#page=215 SN - 0179-4159 SP - 215 EP - 217 PB - Berliner Elektronenspeicherring-Gesellschaft für Synchrotronstrahlung CY - Berlin AN - OPUS4-2490 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin T1 - Spatial resolved trace analysis of Dürer's silver point drawings by means of SR-XRF T2 - EDXRS 2002 - European Conference on Energy Dispersive X-Ray Spectrometry CY - Berlin, Germany DA - 2002-06-16 PY - 2002 AN - OPUS4-2993 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin T1 - Erste Erfahrungen mit der Röntgenfluoreszenzspektrometrie an der BAMline beim Elektronenspeicherring BESSY II T2 - 9. Anwendertreffen Röntgenfluoreszenz- und Funkenmissionsspektrometrie CY - Dortmund, Germany DA - 2002-03-04 PY - 2002 AN - OPUS4-2990 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin T1 - NEW INVESTIGATIONS WITH NANOGRAM MULTI-ELEMENT REFERENCE SAMPLES FOR XRF AND TXRF ANALYSIS T2 - Denver X-Ray Conference CY - Westminster, CO, USA DA - 2013-08-05 PY - 2013 AN - OPUS4-29864 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Cabral, A.R. A1 - Radtke, Martin A1 - Munnik, F. A1 - Lehmann, B. A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich A1 - Tupinambá, M. A1 - Kwitko-Ribeiro, R. T1 - Iodine in alluvial platinum-palladium nuggets: evidence for biogenic precious-metal fixation N2 - Synchrotron radiation-induced X-ray fluorescence (SR-XRF) spectrometry was applied to determine iodine concentrations in alluvial Pt–Pd aggregates with delicate morphological features from Córrego Bom Sucesso, Minas Gerais, Brazil. The millimetre-sized botryoidal and rod-shaped grains of alluvial Pt–Pd–Hg intermetallic compounds have surprisingly high concentrations of iodine, in the range from 10 to ~ 120 μg/g. Because iodine is a strongly biophile element, known to be enriched in peatlands and plant remains in soils by microbial activity, its concentration in the Pt–Pd nuggets suggests biogenic precious-metal fixation in the aqueous alluvial milieu. Biogenic and inorganic processes, such as bioreduction and electrochemical metal accretion, could mutually have contributed to the growth of nanoparticles, formed on organic templates, to millimetric Pt–Pd nuggets. KW - Lodine KW - Pt-Pd nuggets KW - Córrego Bom Sucesso KW - Minas Gerais KW - Brazil PY - 2011 DO - https://doi.org/10.1016/j.chemgeo.2010.12.003 SN - 0009-2541 SN - 1872-6836 VL - 281 IS - 1-2 SP - 125 EP - 132 PB - Elsevier B.V. CY - Amsterdam AN - OPUS4-23174 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin T1 - THE IDEAL SPECIMENT FOR TOTAL REFLECTION X-RAY FLUORESCENCE (TXRF) ANALYSIS: RESULTS FROM SIMULATIONS AND EXPERIMENTAL EVALUATION T2 - Denver X-Ray Conference CY - Westminster, CO, USA DA - 2013-08-05 PY - 2013 AN - OPUS4-29869 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin T1 - Characterization of precious metal objects with SRXRF at the Bamline T2 - Synchrotron Radiation in Art & Archaeology (SR2A-2010) CY - Amsterdam, Netherlands DA - 2010-11-07 PY - 2010 AN - OPUS4-21244 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin T1 - u-SRXRF characterization of Brazilian emeralds T2 - Fifth Joint BER II and BESSY II User Meeting CY - Berlin, Germany DA - 2013-12-04 PY - 2013 AN - OPUS4-29902 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin T1 - From Egypt to Hiddensee – Analysis of Gold with Synchrotron Radiation V N2 - Gold is one of the seven metals already known in antiquity and was used from time immemorial as a medium of exchange and for the production of jewelry because of its luster and rarity. In addition, it is easy to work and largely resistant to chemical influences. Investigations of gold using synchrotron radiation excited X-ray fluorescence analysis are non-destructive and provide information about the chemical elements present in the sample under investigation. The investigations presented here at BAMline focus on questions such as the origin, manufacturing process, and association of gold findings. The different questions are explained by a number of examples ranging from the Viking treasure from Hiddensee to the Nebra Sky Disk and finds from Egypt. The find from Bernstorf is discussed in detail. A Bayesian treatment of the authenticity is shown. T2 - Ringvorlesung Einführung in die Archäometrie CY - Berlin, Germany DA - 01.11.2024 KW - Gold KW - Synchrotron KW - XRF KW - BAMline KW - Bayes PY - 2024 AN - OPUS4-61699 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Rakotondrajoa, Andrianiaina A1 - Buzanich, Günter A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich A1 - Vincze, L. A1 - Raboanary, R. T1 - Improvement of PLS regression-based XRF spectroscopy quantification using multiple step procedure and Monte Carlo simulation N2 - Partial least squares (PLS) regression-based methods have been proven to be a good alternative for quantification in X-ray fluorescence spectroscopy. These methods are fast and easy to use though giving satisfactory results under certain conditions. One of these conditions is the necessity of having a great number of spectra to build the model (training set). The choice of the constituent concentration range in the training set has a big influence on the accuracy of the model. Better accuracy is obtained if the model is built in relatively narrow regions containing (or close to) the real concentration value. In the present work, Monte Carlo (MC) simulated spectra are used to form the training set. The advantage to use MC generated training spectra is the unlimited availability of perfect standards. This paper aims to improve the accuracy of the method by introducing a multiple step procedure in order to build the PLS model using narrow concentration range close to (or containing) the real concentration values in the samples to be measured. This approach consists of an initial guess of the constituents' concentrations and a preliminary PLS model before building the final model. The prediction of ten MC simulated alloy standard samples containing Ti, Mn, Fe, Co, Cu, Zn, Sr, Zr, and Mo using this method allowed to have average relative prediction errors less than 5% for elements with narrow concentration ranges. KW - SR-microXRF KW - Quantification KW - PLS KW - Monte Carlo PY - 2013 DO - https://doi.org/10.1002/xrs.2479 SN - 0049-8246 VL - 42 IS - 4 SP - 183 EP - 188 PB - Wiley CY - Chichester AN - OPUS4-30225 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin T1 - "Golden Past and Future" - Applications of Synchrotron Radiation for Cultural Heritage T2 - 1st INTERNATIONAL CONFERENCE ON INNOVATION IN ART RESEARCH AND TECHNOLOGY INART´13 CY - Evora, Portugal DA - 2013-07-10 PY - 2013 AN - OPUS4-29862 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -