TY - CHAP A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Guerra, M.F. A1 - Martinón-Torres, M. A1 - Lemasson, Q. A1 - Moignard, B. A1 - Pacheco, C. A1 - Pichon, L. A1 - Macdonald, L. A1 - Hess, M. A1 - Tissot, I. ED - Guerra, M. F. ED - Martinón-Torres, M. ED - Quirke, S. T1 - Analytical approaches to Egyptian goldwork N2 - The structure and composition of ancient gold objects retain information about their long history of manufacture, from the exploitation of the ore to the finishing touches, as well as evidence of their use, deposition, and degradation. By developing an efficient analytical strategy, it is possible to retrieve that information. This chapter sets the necessary foundation 131to explore fully the analytical results presented in the following chapters of this volume. The techniques employed in the analyses of the Egyptian jewellery are described and the analytical parameters provided. For more established techniques, only brief introductions are presented, while more recent developments are presented in greater detail. KW - Gold KW - Synchrotron KW - D2XRF KW - Egypt PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-586039 DO - https://doi.org/10.17863/CAM.99681 SP - 131 EP - 191 AN - OPUS4-58603 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Guerra, M. F. A1 - Radtke, Martin A1 - Reiche, I. A1 - Riesemeier, Heinrich A1 - Strub, Erik T1 - Analysis of trace elements in gold alloys by SR-XRF at high energy at the BAMline N2 - Measuring in a non-destructive way the characteristic trace elements of the metal allows following the circulation of gold in the past. The aim of this work is to probe the possibilities of X-ray fluorescence with high energy synchrotron radiation (SR-XRF) at the BAMline at BESSY II to determine the concentration of Pt in ancient gold alloys. A HP-Ge detector was used to measure the Pt K-lines excited with an incident energy of 79.5 keV. Data processing was done by subtraction of a Pt free gold standard spectrum from the spectrum of the sample. Depending on the sample composition, the MDL ranges between 40 and 90 ppm. The first results obtained for a small set of gold alloys of different thickness, size and composition showed that high energy SR-XRF is a significant method for the non-destructive determination of Pt in gold. KW - SR-XRF KW - Gold KW - Provenancing KW - Trace elements PY - 2008 DO - https://doi.org/10.1016/j.nimb.2008.03.008 SN - 0168-583X SN - 1872-9584 VL - 266 IS - 10 SP - 2334 EP - 2338 PB - Elsevier CY - Amsterdam AN - OPUS4-17735 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin T1 - Analysis of trace elements in gold alloys by SR-XRF at high energy at the BAMline T2 - Ecaart 9 (European conference on accelerators in applied research and technology) CY - Florence, Italy DA - 2007-09-03 PY - 2007 AN - OPUS4-16399 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Rodrigues, M. A1 - Schreiner, M. A1 - Melcher, M. A1 - Guerra, M. A1 - Salomon, J. A1 - Radtke, Martin A1 - Alram, M. A1 - Schindel, N. T1 - Analysis of the hoard of Becin using X-ray-based techniques N2 - Four hundred and sixteen silver coins stemming from the Ottoman Empire (16th and 17th centuries) were analyzed to confirm the fineness of the coinage as well as to study the provenance of the alloy used for the coins. As most of the coins showed the typical green patina on their surfaces due to corrosion processes that have led to the depletion of copper in the near surface domains of the silver coins in comparison to their core composition, small samples had to be taken, embedded in synthetic resin, and cross sectioned to investigate the true-heart metal composition. µ-synchrotron micro X-ray fluorescence analysis and µ-proton-induced X-ray emission were applied to determine the silver contents as well as the minor and trace elements. The type of the alloy was investigated as well as if coins minted in different locations demonstrated homogeneous traits concerning the predominant impurities (Au and Bi), which could suggest a common ore. Finally, energy-dispersive microanalysis in a scanning electron microscope was applied to study the homogeneity/heterogeneity of the coins and the presence of surface enrichments and to explain differences between the µ-synchrotron micro X-ray fluorescence analysis and µ-proton-induced X-ray emission measurements concerning the main component. In general, the silver content of the analyzed specimen varies between 90 and 95%. These outcomes have not supported the historical interpretations, which predict that during the period studied, a debasement of approximately 44% of the silver content of the coins should have occurred. KW - SRXRF KW - Silber KW - BAMline PY - 2012 DO - https://doi.org/10.1002/xrs.2415 SN - 0049-8246 VL - 41 IS - 6 SP - 416 EP - 424 PB - Wiley CY - Chichester AN - OPUS4-27723 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Kühbacher, M. A1 - Weseloh, G. A1 - Bertelsmann, H. A1 - Özaslan, M. A1 - Radtke, Martin A1 - Riesemeier, Heinrich A1 - Kyriakopoulos, A. A1 - Behne, D. T1 - Analysis of metal- and metalloid-containing proteins by SRXRF at the BAMline N2 - Pilot studies have been carried out at the BAMline at BESSY II in collaboration with the Bundesanstalt für Materialforschung und -prüfung (BAM) on metal- and metalloid-containing compounds in biological samples after electrophoretic protein separation. After sodium dodecylsulfate polyacrylamide gel electrophoresis (SDS-PAGE) and transfer onto a blotting membrane the distribution of selenium among the proteins of testis homogenate of a rat and a wallaby was determined. The comparison with the autoradiogram of 75Se-labeled proteins separated in the same way showed that of nine seleniumcontaining proteins found in rat testis homogenate by autoradiography four could be detected by synchrotron radiation X-ray fluorescence analysis (SRXRF). PY - 2003 UR - http://www.helmholtz-berlin.de/media/media/oea/web/pr_webseite/druckschriften/berichte/bessy/annualreport2002.pdf#page=333 SN - 0179-4159 SP - 333 EP - 335 PB - Berliner Elektronenspeicherring-Gesellschaft für Synchrotronstrahlung CY - Berlin AN - OPUS4-2495 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hahn, Michael A1 - Buzanich, Günter A1 - Jähn, Katharina A1 - Reinholz, Uwe A1 - Radtke, Martin T1 - Analysis of cobalt deposition in periprosthetic bone specimens by high-resolution synchroton XRF in undecalcified histological thin sections N2 - Increasing numbers of implant revisions are a current clinical issue. Interactions of the endoprosthesis biomaterial with the body affect implantation time by wear processes, i.e. corrosion and abrasion. Previously, cobalt-chrome implants were shown to cause high levels of cobalt ions being deposited in the bone matrix. To determine a poten- tial functional role of these ions on bone homeostasis, we have developed a non-destructive dual analysis of highly sensitive elemental analysis by synchrotron XRF directly in undecalcified histological bone thin sections (4 μm). In this study, samples from 28 bone samples from hip endoprosthesis carriers (Surface Replacement Arthroplasty, metal-on-metal bearing) with an implant lifetime of 17–1750 days were used. Results were compared to age- matched control specimens. The histological analysis identified areas of bone cell activity and assigned them for XRF measurements. Co-Cr wear particles were identified in the bone marrow. In addition, Co ions were highly enriched in the mineralized bone matrix. The cobalt deposits were not homogeneously distributed, and areas of high signal intensity were identified. Co was distinctly deposited in the newly formed osteoid layer, but also within deeper layers of the bone matrix, whereby the Co concentration increased with higher degrees of bone matrix mineralization. In the current study, we determined cobalt accumulations in the bone matrix and showed for the first time via synchrotron XRF with a high spatial resolution direct on histological slides, that cobalt deposits in the mineralized bone matrix in a mineral-specific way that is dependent upon the implant lifetime. KW - Implant material KW - Cobalt deposition KW - Bone matrix KW - High-resolution synchrotron XRF KW - Histology PY - 2019 DO - https://doi.org/10.1016/j.mtla.2019.100290 SN - 2589-1529 VL - 6 SP - 100290, 1 EP - 8 PB - Elsevier Inc. CY - Amsterdam, Niederlande AN - OPUS4-47620 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin T1 - Analysis of ancient gold objects with SRXRF at the BAMline T2 - Technart 2015 CY - Catania, Italien DA - 2015-04-27 PY - 2015 AN - OPUS4-34007 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin A1 - Stalinski, T. T1 - Adaptive Kanalreduktion eines hyperspektralen Bilddatensatzes kombiniert mit k-mean Clustering T2 - Workshop Farbbildverarbeitung - Wuppertal 2014 CY - Wuppertal DA - 2014-09-25 PY - 2014 AN - OPUS4-32365 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Zier, M. A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich A1 - Radtke, Martin A1 - Munnik, F. T1 - Accurate stopping power determination of 15N ions for hydrogen depth profiling by a combination of ion beams and synchrotron radiation N2 - Hydrogen analysis is of particular importance in thin film technology and it is often necessary to obtain a depth profile. The method with the best depth resolution is NRA using the 6385 keV resonance of the 1H(15N,αγ)12C nuclear reaction. The correct quantification of the depth and concentration scales in the measured hydrogen profiles relies on accurate stopping power values. We present a method to deduce these values from a combination of two techniques: NRA and X-ray reflectometry (XRR). This method is applied to the determination of the stopping power of ~6.4 MeV 15N ions in H-containing amorphous Si-layers (a-Si:H). Density-independent stopping powers at different H concentrations are determined by combining the results from NRA and XRR with an overall uncertainty of 3.3%, showing good agreement with SRIM values. This work shows exemplary the methodology for future evaluation of stopping powers for quality assurance in NRA. KW - Nuclear reaction analysis KW - Hydrogen depth profiling KW - Stopping cross section KW - Linear energy transfer KW - Synchrotron radiation KW - XRR PY - 2012 DO - https://doi.org/10.1016/j.nimb.2011.07.027 SN - 0168-583X SN - 1872-9584 VL - 273 SP - 18 EP - 21 PB - Elsevier B.V. CY - Amsterdam AN - OPUS4-25722 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin T1 - ABSORBTION OF THE PRIMARY BEAM IN SR-TXRF ANALYSIS: EXPERIMENTAL VISUALIZATION USING A COLOR X-RAY CAMERA T2 - International Congress on X-Ray Optics and Microanalysis CY - Hamburg, Germany DA - 2013-09-02 PY - 2013 AN - OPUS4-29898 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin T1 - ABSOPTION OF THE PRIMARY BEAM IN SR-TXRF ANALYSIS: EXPERIMENTAL VISUALIZATION USING A COLOR X-RAY CAMERA T2 - Fifth Joint BER II User Meeting CY - Berlin, Germany DA - 2013-12-04 PY - 2013 AN - OPUS4-29901 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Weber, Kathrin A1 - de Oliveira Guilherme Buzanich, Ana A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Stephan-Scherb, Christiane T1 - A µ‐XANES study of the combined oxidation/sulfidation of Fe–Cr model alloys N2 - The precise analysis of cation diffusion profiles through corrosion scales is an important aspect to evaluate corrosion phenomena under multicomponent chemical load, as during high‐temperature corrosion under deposits and salts. The present study shows a comprehensive analysis of cation diffusion profiles by electron microprobe analysis and microbeam X‐ray absorption near edge structure (µ‐XANES) spectroscopy in mixed oxide/sulfide scales grown on Fe–Cr model alloys after exposing them to 0.5% SO2. The results presented here correspond to depth‐dependent phase identification of oxides and sulfides in the corrosion scales by µ‐XANES and the description of oxidation‐state‐dependent diffusion profiles. Scales grown on low‐ and high‐alloyed materials show both a well‐pronounced diffusion profile with a high concentration of Fe3+ at the gas and a high concentration of Fe2+ at the alloy interface. The distribution of the cations within a close‐packed oxide lattice is strongly influencing the lattice diffusion phenomena due to their different oxidation states and therefore different crystal‐field preference energies. This issue is discussed based on the results obtained by µ‐XANES analysis. KW - X-ray absorption spectroscopy KW - Oxidation KW - Sulfidation PY - 2019 DO - https://doi.org/10.1002/maco.201810644 VL - 70 IS - 8 SP - 1360 EP - 1370 PB - Wiley VCH-Verlag AN - OPUS4-47934 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Constantinescu, B. A1 - Vasilescu, A. A1 - Radtke, Martin A1 - Reinholz, Uwe T1 - A study on gold and copper provenance for Romanian prehistoric objects using micro-SR XRF N2 - This study intends to clarify the metal provenance of gold archaeological items using the variation of the Au–Ag ratio and the presence of trace elements as Sn, Sb, Te, and Pb, concentrating on gold Dacian Koson coins, recovered recently. It also extends the area of our investigations to the copper provenance of Bronze Age artifacts—axes, sickles, and celts—found on Romanian territory. The experiments were performed by micro-SR XRF at BESSY Berlin, at the BAM-line facility. Two types of coins (Koson, with and without monogram) were analysed. The conclusions we reached were that most of the monogram coins are made from refined gold (3–5% Ag, less than 0.5% Cu), while the without monogram coins are made from native Transylvanian gold (9–20% Ag, 0.5–2% Cu), of alluvial origin, proved by the presence of Sn, Sb and Te embedded in the gold. The problem of provenance for prehistoric Romanian copper and bronze objects consists in linking their elemental compositional patterns to the ones of the Bronze Age regional mines from Bulgaria, Serbia or Transylvania, most likely used as ore sources for their manufacture. The studied samples present relevant traces of As, Ag, Sb, and Co, suggesting the most probable use of copper from Serbia or northern Bulgaria for their manufacture. KW - X-ray fluorescence KW - Synchrotron radiation KW - Proton induced X-ray emission KW - Archaeometry KW - Gold PY - 2011 DO - https://doi.org/10.1039/c0ja00215a SN - 0267-9477 SN - 1364-5544 VL - 26 IS - 5 SP - 917 EP - 921 PB - Royal Society of Chemistry CY - London AN - OPUS4-23191 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Fittschen, U. A1 - de Oliveira Guilherme Buzanich, Ana A1 - Böttger, S. A1 - Rosenberg, D. A1 - Menzel, M. A1 - Jensen, W. A1 - Busker, M. A1 - Gotlib, Z. A1 - Radtke, Martin A1 - Riesemeier, Heinrich A1 - Wobrauschek, P. A1 - Streli, C. ED - de Oliveira Guilherme Buzanich, Ana T1 - A setup for synchrotron-radiation-induced total reflection X-ray fluorescence and X-ray absorption near-edge structure recently commissioned at BESSY II BAMline N2 - An automatic sample changer chamber for total reflection X-ray fluorescence (TXRF) and X-ray absorption near-edge structure (XANES) analysis in TXRF geometry was successfully set up at the BAMline at BESSY II. TXRF and TXRF-XANES are valuable tools for elemental determination and speciation, especially where sample amounts are limited (<1 mg) and concentrations are low (ng ml⁻¹ to μg ml⁻¹). TXRF requires a well defined geometry regarding the reflecting surface of a sample carrier and the synchrotron beam. The newly installed chamber allows for reliable sample positioning, remote sample changing and evacuation of the fluorescence beam path. The chamber was successfully used showing accurate determination of elemental amounts in the certified reference material NISTwater 1640. Low limits of detection of less than 100 fg absolute (10 pg ml⁻¹) for Ni were found. TXRF-XANES on different Re species was applied. An unknown species of Re was found to be Re in the +7 oxidation state. KW - TXRF KW - TXRF-XANES KW - Sample changer KW - BAMline KW - Re-XANES PY - 2016 DO - https://doi.org/10.1107/S1600577516001995 SN - 1600-5775 VL - 23 IS - 3 SP - 820 EP - 824 PB - International Union of Crystallography AN - OPUS4-38656 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ordavo, I. A1 - Ihle, S. A1 - Arkadiev, V. A1 - Scharf, Oliver A1 - Soltau, H. A1 - Bjeoumikhov, A. A1 - Bjeoumikhova, S. A1 - Buzanich, Günter A1 - Gubzhokov, R. A1 - Günther, A. A1 - Hartmann, R. A1 - Holl, P. A1 - Kimmel, N. A1 - Kühbacher, M. A1 - Lang, M. A1 - Langhoff, N. A1 - Liebel, A. A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich A1 - Schaller, G. A1 - Schopper, F. A1 - Strüder, L. A1 - Thamm, C. A1 - Wedell, R. T1 - A new pnCCD-based color X-ray camera for fast spatial and energy-resolved measurements N2 - We present a new high resolution X-ray imager based on a pnCCD detector and a polycapillary optics. The properties of the pnCCD like high quantum efficiency, high energy resolution and radiation hardness are maintained, while color corrected polycapillary lenses are used to direct the fluorescence photons from every spot on a sample to a corresponding pixel on the detector. The camera is sensitive to photons from 3 to 40 keV with still 30% quantum efficiency at 20 keV. The pnCCD is operated in split frame mode allowing a high frame rate of 400 Hz with an energy resolution of 152 eV for Mn Kα (5.9 keV) at 450 kcps. In single-photon counting mode (SPC), the time, energy and position of every fluorescence photon is recorded for every frame. A dedicated software enables the visualization of the elements distribution in real time without the need of post-processing the data. A description of the key components including detector, X-ray optics and camera is given. First experiments show the capability of the camera to perform fast full-field X-Ray Fluorescence (FF-XRF) for element analysis. The imaging performance with a magnifying optics (3×) has also been successfully tested. KW - X-ray CCD camera KW - pnCCD KW - Fast X-ray imaging KW - XRF KW - Full-field X-ray fluorescence KW - Elemental analysis KW - High quantum efficiency KW - High energy resolution KW - Polycapillary optics PY - 2011 DO - https://doi.org/10.1016/j.nima.2011.05.080 SN - 0168-9002 SN - 0167-5087 VL - 654 SP - 250 EP - 257 PB - North-Holland CY - Amsterdam AN - OPUS4-24370 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kulow, Anicó A1 - Witte, S. A1 - Beyer, S. A1 - de Oliveira Guilherme Buzanich, Ana A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Riesemeier, H. A1 - Streli, C. T1 - A new experimental setup for time- and laterally-resolved X-ray absorption fine structure spectroscopy in a 'single shot' N2 - In this work, a new setup for dispersive XAFS measurements is presented. This reproducible and scanningfree setup yields both time- and laterally-resolved XAFS experiments in a ‘single-shot’. It allows a straightforward adjustment for probing different elements covering many relevant applications in materials science. An incoming energetic broadband beam is diffracted by a Si (111) crystal after passing through the sample and collected by an area sensitive detector. Depending on the energy range of the incoming beam, XANES and/or EXAFS spectra can be recorded with a time resolution down to 1 s. The feasibility of this setup was demonstrated at the BAMline at BESSY II (Berlin, Germany) with reference Fe and Cu foils and the results are hereby presented and discussed. Additionally, an application where time resolution on the second scale is required is briefly evaluated. The presented example concerns studying early stages of zinc(II)2-methylimidazolate (ZIF-8) crystallization. This is particularly important for biomedical applications. KW - X-ray spectroscopy KW - X-ray absorption fine structure KW - Time-resolved KW - Laterally-resolved KW - Experimental setup PY - 2019 DO - https://doi.org/10.1039/c8ja00313k SN - 0267-9477 SN - 1364-5544 VL - 34 IS - 1 SP - 239 EP - 246 PB - Royal Society of Chemistry CY - London AN - OPUS4-47207 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Tissot, I. A1 - Troalen, L.G. A1 - Manso, M. A1 - Ponting, M. A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Barreiros, M. A. A1 - Shaw, I. A1 - Carvalho, M.L. A1 - Guerra, M.F. T1 - A multi-analytical approach to gold in Ancient Egypt: Studies on provenance and corrosion N2 - Recent results from a three-year multi-disciplinary project on Ancient Egyptian gold jewellery revealed that items of jewellery from the Middle Kingdom to the New Kingdom were manufactured using a variety of alluvial gold alloys. These alloys cover a wide range of colours and the majority contain Platinum Group Elements inclusions. However, in all the gold foils analysed, these inclusions were found to be absent. In this work a selection of gilded wood and leather items and gold foil fragments, all from the excavations by John Garstang at Abydos (primarily from Middle Kingdom graves), were examined using Scanning Electron Microscopy-Energy Disperse Spectroscopy (SEM-EDS), X-Ray Fluorescence (µXRF), Particle Induced X-Ray Emission (µPIXE) and Double Dispersive X-Ray Fluorescence (D²XRF). The work allowed us to characterise the composition of the base-alloys and also to reveal the presence of Pt at trace levels, confirming the use of alluvial gold deposits. Corrosion products were also investigated in the foils where surface tarnish was visually observed. Results showed that the differences in the colour of corrosion observed for the foils are related not only to the thickness of the corrosion layer but also to a multi-layer structure containing the various corrosion products. KW - Gold KW - Egypt KW - PGE KW - Provenance KW - Corrosion KW - muXRF KW - muPIXE KW - D2XRF KW - SEM-EDS PY - 2015 DO - https://doi.org/10.1016/j.sab.2015.03.012 SN - 0584-8547 SN - 0038-6987 VL - 108 SP - 75 EP - 82 PB - Elsevier CY - Amsterdam AN - OPUS4-33155 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Cakir, Cafer Tufan A1 - de Oliveira Guilherme Buzanich, Ana A1 - Radtke, Martin T1 - A Digital Twin Workflow for Optimizing X-ray Emission Spectroscopy (XES) Parameters in Material Science N2 - In this contribution, I present a digital twin-based workflow designed to optimize experimental parameters in X-ray emission spectroscopy (XES), with a focus on reproducibility, data integration, and alignment with FAIR (Findable, Accessible, Interoperable, Reusable) principles in materials science and engineering (MSE). The developed pipeline begins with automated retrieval of crystallographic information from the Materials Project database based on a given sample composition. This structural data is then used to simulate the corresponding XES spectra using FDMNES, allowing for accurate prediction of element-specific emission lines. The simulated emission lines are fed into an X-ray tracing (XRT) module, which builds a virtual replica of the experimental setup. This digital twin environment enables predictive modeling of spectrometer performance based on geometric configurations. The optimization focuses on two key parameters: the choice of the analyzing crystal and the distance between the sample and crystal (which also defines the crystal–detector distance due to Bragg condition constraints). An active learning algorithm is employed to iteratively adjust these parameters in order to achieve a desired energy-per-pixel (E/pixel) resolution with minimal intensity loss, enabling efficient, data-driven experimental planning. By integrating data-driven simulations with real-time optimization strategies, this workflow supports efficient experiment planning while minimizing resource consumption and human error. Furthermore, all stages of the process—from data collection and simulation to optimization and visualization—are structured to ensure traceability and interoperability, facilitating future reuse and collaborative research. I hope this contribution aligns well with the topic “Workflows for FAIR MSE Data” and offers a concrete example of how digital twins can be harnessed to improve the design, execution, and documentation of spectroscopy experiments in the MSE domain. T2 - Opportunities and Challenges of FAIR Data at Photon and Neutron Facilities CY - Bad Honnef, Germany DA - 12.10.2025 KW - Digital-Twin KW - XES KW - Optimization KW - Machine Learning PY - 2025 AN - OPUS4-64676 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gauert, C. A1 - Schannor, M. A1 - Hecht, L. A1 - Radtke, Martin A1 - Reinholz, Uwe T1 - A comparison of in situ analytical methods for trace element measurement in gold samples from various South African gold deposits N2 - Trace element concentrations in gold grains from various geological units in South Africa were measured in situ by field emission-electron probe microanalysis (FE-EPMA), laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) and synchrotron micro X-ray fluorescence spectroscopy (SR-µ-XRF). This study assesses the accuracy, precision and detection limits of these mostly non-destructive analytical methods using certified reference materials and discusses their application in natural sample measurement. FE-EPMA point analyses yielded reproducible and discernible concentrations for Au and trace concentrations of S, Cu, Ti, Hg, Fe and Ni, with detection limits well below the actual concentrations in the gold. LA-ICP-MS analyses required larger gold particles (> 60 µm) to avoid contamination during measurement. Elements that measured above detection limits included Ag, Cu, Ti, Fe, Pt, Pd, Mn, Cr, Ni, Sn, Hg, Pb, As and Te, which can be used for geochemical characterisation and gold fingerprinting. Although LA-ICP-MS measurements had lower detection limits, precision was lower than FE-EPMA and SR-µ-XRF. The higher variability in absolute values measured by LA-ICP-MS, possibly due to micro-inclusions, had to be critically assessed. Non-destructive point analyses of gold alloys by SR-µ-XRF revealed Ag, Fe, Cu, Ni, Pb, Ti, Sb, U, Cr, Co, As, Y and Zr in the various gold samples. Detection limits were mostly lower than those for elements measured by FE-EPMA, but higher than those for elements measured by LA-ICP-MS. N2 - Les concentrations en éléments traces de grains d'or provenant de différentes unités géologiques d'Afrique du Sud ont été mesurées in situ par microsonde électronique à émission de champ (FE-EPMA), spectrométrie de masse couplée à une source plasma et un système d'ablation laser (LA-ICP-MS) et micro spectroscopie de fluorescence des rayons X au Synchrotron (SR-µ-XRF). Cette étude évalue l'exactitude, la précision et les limites de détection de ces méthodes d'analyse pour la plupart non-destructives en utilisant des matériaux de référence certifiés, et discute de leur application dans les mesures sur échantillon naturel. Les points d'analyses FE-EPMA ont fournis des concentrations reproductibles et discernables pour l'Au et des concentrations en traces de S, Cu, Ti, Hg, Fe et Ni, avec des limites de détection bien inférieures aux concentrations réelles dans l'or. Les analyses LA-ICP-MS ont nécessitées des particules d'or de plus grande taille (> 60 µm) pour éviter toute contamination pendant la mesure. Les éléments mesurés au-dessus des limites de détection inclus Ag, Cu, Ti, Fe, Pt, Pd, Mn, Cr, Ni, Sn, Hg, Pb, A et Te, qui peuvent être utilisés pour les caractérisations géochimique et le «fingerprinting» de l'or. Bien que les mesures LA-ICP-MS aient des limites de détection plus basses, la précision est inférieure par rapport à celles de la microsonde FE et de la SR-µ-XRF. La plus grande variabilité des valeurs absolues mesurées par LA-ICP-MS, probablement reliée à la présence de micro-inclusions, a du être évaluée de manière critique. Les points d'analyse non-destructifs des alliages d'or par SR-µ-XRF ont révélés la présence de Ag, Fe, Cu, Ni, Pb, Ti, Sb, U, Cr, Co, As, Y et Zr dans les différents échantillons. Les limites de détection ont été pour la plupart inférieures à celles des éléments mesurés par FE-EPMA, mais supérieures à celles des éléments mesurés par LA-ICP-MS. KW - Trace elements KW - Gold KW - FE-EPMA KW - LA-ICP-MS KW - SR-µ-XRF KW - Precision KW - Précision KW - Comparison of techniques KW - Éléments traces PY - 2016 DO - https://doi.org/10.1111/j.1751-908X.2015.00362.x SN - 1639-4488 SN - 1751-908X VL - 40 IS - 2 SP - 267 EP - 289 PB - Blackwell CY - Oxford AN - OPUS4-34882 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Berger, Achim A1 - Görner, Wolf A1 - Merchel, Silke A1 - Radtke, Martin A1 - Riesemeier, Heinrich A1 - Reiche, I. A1 - Riederer, J. T1 - A closer look at Albrecht Dürer's drawings (1471-1528) PY - 2002 UR - http://www.helmholtz-berlin.de/media/media/oea/web/pr_webseite/druckschriften/infos/bessy/highlights2001.pdf#page=32 SN - 0179-4159 SP - 32 EP - 33 PB - Berliner Elektronenspeicherring-Gesellschaft für Synchrotronstrahlung CY - Berlin AN - OPUS4-1323 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Kanngießer, B. A1 - Malzer, W. A1 - Fuentes Rodriguez, A. A1 - Reiche, I. A1 - Voigt, F. A1 - Radtke, Martin T1 - 3D micro X-ray fluorescence spectroscopy - combining elemental analysis with chemical speciation PY - 2004 UR - http://www.helmholtz-berlin.de/media/media/oea/web/pr_webseite/druckschriften/berichte/bessy/annualreport2003.pdf#page=495 SN - 0179-4159 SP - 495 EP - 497 PB - Berliner Elektronenspeicherring-Gesellschaft für Synchrotronstrahlung CY - Berlin AN - OPUS4-3513 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin T1 - 3D and Beyond - Basics and Applications of the Color X-ray Camera T2 - Denver X-ray Conference CY - BIG SKY RESORT, BIG SKY, MONTana, USA DA - 2014-07-28 PY - 2014 AN - OPUS4-32366 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin T1 - "Golden Past and Future" - Applications of Synchrotron Radiation for Cultural Heritage T2 - 1st INTERNATIONAL CONFERENCE ON INNOVATION IN ART RESEARCH AND TECHNOLOGY INART´13 CY - Evora, Portugal DA - 2013-07-10 PY - 2013 AN - OPUS4-29862 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -