TY - JOUR A1 - Guerra, M. F. A1 - Calligaro, T. A1 - Radtke, Martin A1 - Reiche, I. A1 - Riesemeier, Heinrich T1 - Fingerprinting ancient gold by measuring Pt with spatially resolved high energy Sy-XRF N2 - Trace elements of ancient gold such as Pt, give fundamental information on the circulation of the metal in the past. In the case of objects from the cultural heritage, the determination of trace elements requires non-destructive point analysis in general. These conditions and the need of good detection limits restrain the number of applicable analytical techniques. After the development of a PIXE set-up with a selective Cu or Zn filter of 75 µm and of a PIXE-XRF set-up using a primary target of As, we tested the possibilities of spatially resolved Sy-XRF to determine Pt in gold alloys. With a Zn filter, PIXE showed a detection limit of 1000 ppm in gold while PIXE-XRF lowers this detection limit down to 80 ppm. This last value being constrained by the resonant Raman effect produced on gold. In order to improve the detection limit of Pt keeping the non-destructiveness and access to point analysis, we developed an analytical protocol for XRF with synchrotron radiation at BESSY II, using the BAMline set-up. The L-lines of Pt were excited by a beam of energy above and below 11.564 keV and measured using a Si(Li) detector with a 50 µm Cu filter. A µ-beam of 100–250 µm2 was used according to the size of the sample. The determination of the Pt content in the samples was carried out by Monte-Carlo simulation and subtraction of Au and Pt spectra obtained on pure standards. The limit of detection for Pt of 20 ppm was determined by using certified standards. The detection limits of a small set of other characteristic elements of gold were also measured using an incident energy of 33 keV. KW - PIXE-XRF KW - Sy-XRF KW - Pt KW - Ancient gold KW - Fingerprinting PY - 2005 DO - https://doi.org/10.1016/j.nimb.2005.06.150 SN - 0168-583X SN - 1872-9584 VL - 240 IS - 1-2 SP - 505 EP - 511 PB - Elsevier CY - Amsterdam AN - OPUS4-14236 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Yun, Tae Gyu A1 - Chen, Boqiang A1 - Wells, Sarah A1 - Lim, Younghwan A1 - Kim, Jun Seop A1 - de Oliveira Guilherme Buzanich, Ana A1 - Radtke, Martin A1 - Waegele, Matthias M. A1 - Risch, Marcel A1 - Grimaud, Alexis ED - de Oliveira Guilherme Buzanich, Ana T1 - Extrinsic and Intrinsic Factors Governing the Electrochemical Oxidation of Propylene in Aqueous Solutions N2 - The electrochemical synthesis of commoditychemicals such as epoxides and glycols offers a sustainablealternative to conventional methods that involve hazardouschemicals. Efforts to improve the yield and selectivity of propyleneoxidation using Pd-based catalysts have been shown to be highlysensitive to applied potential, pH, and electrochemical cell design.Record efficiencies and yields were obtained by substitution ofPdO by 4d or 5d transition metals, including Pt, with thus far littlerationale regarding the origin for the improvement. Throughelectrochemical analysis, scanning transmission electron micros-copy, X-ray absorption spectroscopy, and surface-enhanced infraredabsorption spectroscopy, we investigated the mechanism ofpropylene oxidation on Pd-based catalysts. We demonstrate thatadsorbates forming on PdO, where Pd adopts a square-planar coordination [PdO4], differ from that forming on the surface ofoxidized metallic Pd catalysts with an oxo intermediate mediating propylene oxidation on PdO. We further show that Pt substitutionin PdO does not modify this oxo intermediate. Varying pH, we found that the onset for propylene oxidation is pH independent,indicating a potential-determining step where the proton is not involved in and similar reaction pathway in acidic and near-neutralconditions. Finally, our work undoubtedly demonstrates that high Faradaic efficiency toward propylene glycol and propylene oxideformation, such as those previously reported in the literature, can be achieved by means of electrode engineering and mastery ofmass transport and local pH. Notably, we achieved ≈100% faradaic efficiency for propylene glycol at 1.7 V vs RHE in acidic mediausing a Pt-substituted PdO catalyst loaded onto a gas diffusion electrode. KW - XAS KW - Electrochemistry KW - Popylene oxidation KW - 4d metals PY - 2025 DO - https://doi.org/10.1021/jacs.5c02585 SN - 0002-7863 VL - 147 IS - 14 SP - 12318 EP - 12330 PB - American Chemical Society (ACS) AN - OPUS4-63112 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Valentim Gelamo, Rogério A1 - Bueno Leite, Natália A1 - Amadeu, Nader A1 - Reis Pedreira Muniz Tavares, Michel A1 - Oberschmidt, Dirk A1 - Klemm, Sophie A1 - Fleck, Claudia A1 - Cakir, Cafer-Tufan A1 - Radtke, Martin A1 - Aparecido Moreto, Jéferson T1 - Exploring the Nb2O5 coating deposited on the Ti-6Al-4V alloy by a novel GE-XANES technique and nanoindentation load-depth N2 - This research group has been demonstrating the significant advantages of using Nb2O5 coatings for functionalizing titanium, aluminium, and stainless steels. Regarding the biomedical sector and considering Ti-6Al-4V alloy, the reactive sputtering technique improved the cell viability, the osteogenic performance of cells involved in the osseointegration process as well as the ability to delay bacterial proliferation. The characteristics of the Nb2O5 coatings were assessed before by using standard methods, which provide information only a few tens of nanometers depth. Given that the Nb2O5 coating fabricated in this work exhibits a thickness of approximately 300 nm, the GE-XANES technique emerges as the most suitable method for this analysis. Additional information was provided with the aid of nanoindentation load-depth (P-h) curves. GE-XANES results indicated the formation of a homogeneous layer of Nb2O5 coating on the Ti-6Al-4V surfaces. The deposition process improved the surface hardness of the Ti-6Al-4V alloy (4.38 GPa versus 5.62 GPa) considering the 2 mN load. KW - BAMline KW - GE-XANES KW - Synchrotron PY - 2024 DO - https://doi.org/10.1016/j.matlet.2023.135584 SN - 0167-577X VL - 355 SP - 1 EP - 4 PB - Elsevier B.V. AN - OPUS4-60835 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Cakir, Cafer Tufan A1 - Piotrowiak, T. A1 - Reinholz, Uwe A1 - Ludwig, A. A1 - Emmerling, Franziska A1 - Streli, C. A1 - de Oliveira Guilherme Buzanich, Ana A1 - Radtke, Martin T1 - Exploring the Depths of Corrosion: A Novel GE-XANES Technique for Investigating Compositionally Complex Alloys N2 - In this study, we propose the use of nondestructive, depth-resolved, element-specific characterization using grazing exit X-ray absorption near-edge structure spectroscopy (GE-XANES) to investigate the corrosion process in compositionally complex alloys (CCAs). By combining grazing exit X-ray fluorescence spectroscopy (GE-XRF) geometry and a pnCCD detector, we provide a scanning-free, nondestructive, depth-resolved analysis in a sub-micrometer depth range, which is especially relevant for layered materials, such as corroded CCAs. Our setup allows for spatial and energy-resolved measurements and directly extracts the desired fluorescence line, free from scattering events and other overlapping lines. We demonstrate the potential of our approach on a compositionally complex CrCoNi alloy and a layered reference sample with known composition and specific layer thickness. Our findings indicate that this new GE-XANES approach has exciting opportunities for studying surface catalysis and corrosion processes in real-world materials. KW - Degradation mechanisms KW - Grazin exit XANES KW - Depth resolved XANES KW - Compositional complex alloys KW - Corrosion PY - 2023 DO - https://doi.org/10.1021/acs.analchem.3c00404 VL - 95 SP - 4810 EP - 4818 PB - ACS Publications AN - OPUS4-57823 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - de Oliveira Guilherme Buzanich, Ana A1 - Radtke, Martin A1 - Emmerling, Franziska ED - Rogge, Andreas ED - Meng, Birgit T1 - Exploring new materials for Green Intelligent Building - How can our BAMline help? N2 - In the scope of exploring and characterizing new materials related to Green Intelligent Building (GIB), we will provide an overview of the X-ray spectroscopy and diffraction analytical methods available at the BAMline /1/. and Myspot beamlines. These are two universal beamlines at the Berlin Synchrotron BESSY-II, where BAM has access and supervision role. Overarching electronic and structural properties at different time and length scales, such measurements enable a real-time characterization of materials properties. We will show-case in situ and ex situ deterioration and hydration studies on cement-based constructure materials. T2 - 11. Jahrestagung des DAfStb mit 63. Forschungskolloquium der BAM Green Intelligent Building CY - Berlin, Germany DA - 16.10.2024 KW - BAMline KW - Scope of exploring KW - Green intelligent building PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-612882 SN - 978-3-9818564-7-7 SP - 30 EP - 36 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-61288 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Lilensten, L. A1 - Provost, K. A1 - Perrière, L. A1 - Fonda, E. A1 - Couzinié, J. A1 - Amman, F. A1 - Radtke, Martin A1 - Dirras, G. A1 - Guillot, I. T1 - Experimental investigation of the local environment and lattice distortion in refractory medium entropy alloys N2 - EXAFS analysis of pure elements, binary and ternary equiatomic refractory alloys within the Nb-Zr-Ti-Hf- Ta system is performed at the Nb and Zr K-edges to analyze the evolution of the chemical local environ- ment and the lattice distortion. A good mixing of the elements is found at the atomic scale. For some compounds, a distribution of distances between the central atom and its neighbors suggests a distortion of the structure. Finally, analysis of the Debye-Waller parameters shows some correlation with the lat- tice distortion parameter δ², and allows to quantify experimentally the static disorder in medium entropy alloys. KW - BAMline KW - Refractory alloys KW - EXAFS KW - Debye-Waller parameter PY - 2022 DO - https://doi.org/10.1016/j.scriptamat.2022.114532 SN - 1359-6462 VL - 211 SP - 1 EP - 6 PB - Elsevier Ltd. AN - OPUS4-55287 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin T1 - Experiences with the Color X-Ray Camera at the BAMline T2 - X-ray Spectroscopy Detectors for Present and Future Synchrotron Storage rings: Opportunities for Horizon 2020 CY - Paris, Frankreich DA - 2015-03-16 PY - 2015 AN - OPUS4-34009 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Nowak, S.H. A1 - Bjeoumikhov, A. A1 - Von Borany, J. A1 - Buchriegler, J. A1 - Munnik, F. A1 - Petric, M. A1 - Renno, A.D. A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Scharf, O. A1 - Strüder, L. A1 - Wedell, R. A1 - Ziegenrücker, R. T1 - Examples of XRF and PIXE imaging with few microns resolution using SLcam® a color X-ray camera N2 - We present results of recent development of the color X-ray camera, type SLcam®, allowing detection of X-ray images with few microns resolution. Such spectral resolution is achieved with the use of high-quality polycapillary optics combined with sub-pixel resolution. Imaging of Siemens star resolution test chart reveals that the resolution limit of SLcam® can go down to nearly 5µm. Several real sample examples of measurements carried out at the laboratory, synchrotron, and particle-induced X-ray emission beamlines are shown. This is the first time SLcam® is used as particle-induced X-ray emission detector. KW - X-ray KW - Color X-ray camera KW - CXC KW - Synchrotron radiation KW - BESSY KW - BAMline PY - 2015 DO - https://doi.org/10.1002/xrs.2590 SN - 0049-8246 VL - 44 IS - 3 SP - 135 EP - 140 PB - Wiley & Sons, Ltd. CY - Chichester AN - OPUS4-33170 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Lutz, C. A1 - Hampel, S. A1 - Ke, X. A1 - Beuermann, S. A1 - Turek, T. A1 - Kunz, U. A1 - de Oliveira Guilherme Buzanich, Ana A1 - Radtke, Martin A1 - Fittschen, U. T1 - Evidence for redox reactions during vanadium crossover inside the nanoscopic water-body of Nafion 117 using X-ray absorption near edge structure spectroscopy N2 - A major source of capacity fade of the common vanadium redox flow battery (VRFB) is the vanadium ion transport through the separator. However, different transport models disagree significantly in the diffusion coefficient for the different V species and the influence of different transport mechanisms. The underlying hypothesis of this work is that reactions inside the membrane are partly responsible for these discrepancies. Accordingly, it was investigated if redox reactions inside the nanoscopic water body of Nafion 117 can occur. X-ray absorption near edge structure spectroscopy (XANES) was used to distinguish between the different V species inside hydrated Nafion 117 and novel PVDF-based membranes. It was validated that the speciation of vanadium can be performed using the pre-edge peak energy and intensity. The experiments were performed as follows: strips of the membrane were exposed from one site to a V3+ solution (green) and from the other site to a VO2+ solution (yellow). The ions could diffuse into the membrane from both sides. A change of color of the membrane strip was observed. The blue color in the middle of the strip indicated that VO2+ was formed where V3+ and VO2+ got in contact. Using XANES this reaction inside Nafion was proven. KW - PVDF-Based membrane KW - VRFB KW - Vanadium speciation KW - XANES KW - Nafion 117 PY - 2020 DO - https://doi.org/10.1016/j.jpowsour.2020.229176 VL - 483 SP - 229176 PB - Elsevier B.V. AN - OPUS4-51719 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin T1 - Evaluation of total reflection X-ray fluorescence (TXRF) analysis using a color X-ray camera (CXC) T2 - 15th International Conference on Total Reflection X-Ray Fluorescence Analysis and Related Methods (TXRF2013) CY - Osaka, Japan DA - 2013-09-23 PY - 2013 AN - OPUS4-29859 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -