TY - JOUR A1 - Eichelbaum, M. A1 - Rademann, K. A1 - Müller, Ralf A1 - Radtke, Martin A1 - Görner, Wolf T1 - Zur Chemie des Goldes in Silicatgläsern: Untersuchungen zum nicht-thermisch aktivierten Wachstum von Goldclustern KW - Glas KW - Goldcluster KW - Nanophotonik PY - 2005 DO - https://doi.org/10.1002/ange.200502174 SN - 0044-8249 SN - 0932-2140 SN - 1521-3757 VL - 117 IS - 48 SP - 8118 EP - 8122 PB - Wiley-VCH CY - Weinheim AN - OPUS4-7691 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Riesemeier, Heinrich A1 - Ecker, Klaus A1 - Görner, Wolf A1 - Müller, Bernd R. A1 - Radtke, Martin A1 - Krumrey, M. T1 - Layout and first XRF Applications of the BAMline at BESSY II+ N2 - The first hard x-ray beamline at BESSY II has been installed by BAM and PTB at a superconducting 7 T wavelength shifter. The main optical elements of the beamline are a double-multilayer monochromator and a double-crystal monochromator. Depending on the application, the two devices are used separately or in-line. The main applications of the monochromatic radiation with photon energies up to 60 keV are x-ray fluorescence analysis, micro computed tomography, x-ray topography, detector calibration and reflectometry. Calculable undispersed radiation up to 200 keV is available for radiometric applications. KW - BAMline KW - XRF PY - 2005 DO - https://doi.org/10.1002/xrs.750 SN - 0049-8246 VL - 34 IS - 2 SP - 160 EP - 163 PB - Wiley CY - Chichester AN - OPUS4-11929 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Reiche, I. A1 - Radtke, Martin A1 - Berger, Achim A1 - Görner, Wolf A1 - Merchel, Silke A1 - Riesemeier, Heinrich A1 - Bevers, H. T1 - Spatially resolved synchrotron radiation induced X-ray fluorescence analyses of rare Rembrandt silverpoint drawings N2 - New analyses of a series of very rare silverpoint drawings that were executed by Rembrandt Harmensz. van Rijn (1606–1669) which are kept today in the Kupferstichkabinett (Museum of Prints and Drawings) of the State Museums of Berlin are reported here. Analysis of these drawings requires particular attention because the study has to be fully non-destructive and extremely sensitive. The metal alloy on the paper does not exceed some hundreds of µg/cm². Therefore, synchrotron radiation induced X-ray fluorescence (SR-XRF) is – together with external micro-proton-induced X-ray emission – the only well-suited method for the analyses of metalpoint drawings. In some primary work, about 25 German and Flemish metalpoint drawings were investigated using spatially resolved SR-XRF analysis at the BAMline at BESSY. This study enlarges the existing French–German database of metalpoint drawings dating from the 15th and 16th centuries, as these Rembrandt drawings originate from the 17th century where this graphical technique was even rarer and already obsolete. It also illustrates how SR-XRF analysis can reinforce art historical assumptions on the dating of drawings and their connection. KW - X-ray spectrometry KW - XRF KW - Röntgenfluoreszenzanalyse KW - RFA KW - Silverpoint drawing KW - Silberstiftzeichnung PY - 2006 DO - https://doi.org/10.1007/s00339-006-3505-4 SN - 0947-8396 VL - 83 IS - 2 SP - 169 EP - 173 PB - Springer CY - Berlin AN - OPUS4-12532 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ecker, Klaus A1 - Wätjen, U. A1 - Berger, Achim A1 - Persson, L. A1 - Pritzkow, Wolfgang A1 - Radtke, Martin A1 - Riesemeier, Heinrich T1 - RBS, SY-XRF, INAA and ICP-IDMS of antimony implanted in silicon - A multi-method approach to characterize and certify a reference material N2 - A layer of Sb atoms, implanted with an energy of 400 keV and a nominal dose of 5×1016 atoms/cm2 into a high purity silicon wafer, was certified for its areal density (atoms/cm2) using Rutherford backscattering spectrometry (RBS), instrumental neutron activation analysis (INAA) and inductively coupled plasma isotope dilution mass spectrometry (ICP-IDMS) and for its isotope ratio using INAA and ICP-IDMS. Excellent agreement between the results of the different independent methods was found. In the present work, the measurements of the homogeneity of the areal density of Sb, previously determined with RBS in spots having 1 mm diameter, are improved with synchrotron X-ray fluorescence analysis: Higher precision in even smaller sample spots allows to estimate a reduced inhomogeneity of the whole batch of samples of the order of only 0.4%. Thus the uncertainty of the certified value can further be reduced. Down to fractions of a chip with 0.3×0.4 mm2 area, the areal density is now certified as (4.81±0.06)×1016 Sb atoms/cm2, where the expanded uncertainty 0.06 (coverage factor k=2) corresponds to only 1.2%. The relative merits of the different analytical methods are discussed. KW - Certified reference material KW - RBS KW - INAA KW - ICP-IDMS KW - XRF KW - SY-XRF PY - 2002 DO - https://doi.org/10.1016/S0168-583X(01)01038-2 SN - 0168-583X SN - 1872-9584 VL - 188 IS - 1-4 SP - 120 EP - 125 PB - Elsevier CY - Amsterdam AN - OPUS4-13870 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Procop, Mathias A1 - Radtke, Martin A1 - Krumrey, M. A1 - Hasche, K. A1 - Schädlich, S. A1 - Frank, W. T1 - Electron probe microanalysis (EPMA) measurement of thin-film thickness in the nanometre range N2 - The thickness of thin films of platinum and nickel on fused silica and silicon substrates has been determined by EPMA using the commercial software STRATAGEM for calculation of film thickness. Film thickness ranged in the order 10 nm. An attempt was made to estimate the confidence range of the method by comparison with results from other methods of analysis. The data show that in addition to the uncertainty of the spectral intensity measurement and the complicated fitting routine, systematic deviation caused by the underlying model should be added. The scattering in the results from other methods does not enable specification of a range of uncertainty, but deviations from the real thickness are estimated to be less than 20%. KW - Electron probe microanalysis KW - EPMA KW - Thin films KW - Thickness measurement KW - X-rays PY - 2002 DO - https://doi.org/10.1007/s00216-002-1514-5 SN - 1618-2642 SN - 1618-2650 VL - 374 SP - 631 EP - 634 PB - Springer CY - Berlin AN - OPUS4-7090 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Zier, M. A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich A1 - Radtke, Martin A1 - Munnik, F. T1 - Accurate stopping power determination of 15N ions for hydrogen depth profiling by a combination of ion beams and synchrotron radiation N2 - Hydrogen analysis is of particular importance in thin film technology and it is often necessary to obtain a depth profile. The method with the best depth resolution is NRA using the 6385 keV resonance of the 1H(15N,αγ)12C nuclear reaction. The correct quantification of the depth and concentration scales in the measured hydrogen profiles relies on accurate stopping power values. We present a method to deduce these values from a combination of two techniques: NRA and X-ray reflectometry (XRR). This method is applied to the determination of the stopping power of ~6.4 MeV 15N ions in H-containing amorphous Si-layers (a-Si:H). Density-independent stopping powers at different H concentrations are determined by combining the results from NRA and XRR with an overall uncertainty of 3.3%, showing good agreement with SRIM values. This work shows exemplary the methodology for future evaluation of stopping powers for quality assurance in NRA. KW - Nuclear reaction analysis KW - Hydrogen depth profiling KW - Stopping cross section KW - Linear energy transfer KW - Synchrotron radiation KW - XRR PY - 2012 DO - https://doi.org/10.1016/j.nimb.2011.07.027 SN - 0168-583X SN - 1872-9584 VL - 273 SP - 18 EP - 21 PB - Elsevier CY - Amsterdam AN - OPUS4-25722 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Rodrigues, M. A1 - Schreiner, M. A1 - Melcher, M. A1 - Guerra, M. A1 - Salomon, J. A1 - Radtke, Martin A1 - Alram, M. A1 - Schindel, N. T1 - Characterization of the silver coins of the Hoard of Becin by x-ray based methods N2 - Four hundred sixteen silver coins stemming from the Ottoman Empire (16th and 17th centuries) were analyzed in order to confirm the fineness of the coinage as well as to study the provenance of the alloy used for the coins. As most of the coins showed the typical green patina on their surfaces due to corrosion processes which have led to the depletion of copper in the near-surface domains of the silver coins in comparison to their core composition, small samples by cutting splinters from the coins had to be taken, embedded in synthetic resin and cross-sectioned in order to investigate the true-heart metal composition. The type of the alloy was investigated as well as if coins minted in different locations demonstrated homogeneous traits concerning the predominant impurities which could suggest a common ore. Several X-ray based techniques (µ-XRF, µ-SRXRF and µ-PIXE) could be applied in order to determine the silver contents as well as the minor and trace elements. Finally, SEM/EDX was applied in order to study the homogeneity/heterogeneity of the coins and the presence of surface enrichments. In general, the silver content of the analyzed specimen varies between 90% and 95%. These outcomes have not supported the historical interpretations, which predict that during the period studied a debasement of approximately 44% of the silver content of the coins should have occurred. KW - PIXE KW - SRXRF KW - SEM/EDX KW - Silver coins PY - 2011 DO - https://doi.org/10.1016/j.nimb.2011.04.068 SN - 0168-583X SN - 1872-9584 VL - 269 IS - 24 SP - 3041 EP - 3045 PB - Elsevier B.V. CY - Amsterdam AN - OPUS4-25289 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Constantinescu, B. A1 - Bugoi, R. A1 - Cojocaru, V. A1 - Radtke, Martin A1 - Calligaro, T. A1 - Salomon, J. A1 - Pichon, L. A1 - Röhrs, S. A1 - Ceccato, D. A1 - Oberländer-Târnoveanu, E. T1 - Micro-SR-XRF and micro-PIXE studies for archaeological gold identification - The case of Carpathian (Transylvanian) gold and of Dacian bracelets N2 - Trace-elements are more significant for provenancing archaeological metallic artifacts than the main components. For gold, the most promising elements are platinum group elements (PGE), Sn, Te, Sb, Hg and Pb. Several small fragments of natural Transylvanian gold – placer and primary – were studied by using micro-PIXE technique at the Legnaro National Laboratory AN2000 microbeam facility, Italy and at the AGLAE accelerator, C2RMF, Paris, France and by using micro synchrotron radiation X-ray fluorescence (micro-SR-XRF) at BESSY synchrotron, Berlin, Germany. The goal of the study was to identify the trace-elements, especially Sn, Sb and Te. A spectacular application to five Dacian gold bracelets authentication is presented (Sn and Sb traces). KW - Micro-PIXE KW - Micro-SR-XRF KW - Gold KW - Dacian bracelets KW - Transylvania PY - 2008 DO - https://doi.org/10.1016/j.nimb.2008.03.054 SN - 0168-583X SN - 1872-9584 VL - 266 IS - 10 SP - 2325 EP - 2328 PB - Elsevier CY - Amsterdam AN - OPUS4-17736 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Eichelbaum, M. A1 - Rademann, K. A1 - Müller, Ralf A1 - Radtke, Martin A1 - Riesemeier, Heinrich A1 - Görner, Wolf T1 - Vom Atom zum Nanodraht: Kontrolliertes Wachstum von Edelmetall-Nanokristalliten in Kalk-Natron-Silikatglas T2 - 79. Glastechnische Tagung CY - Würzburg, Deutschland DA - 2005-05-23 KW - Glas KW - Metallnanocluster KW - Optische Eigenschaften PY - 2005 SN - 3-921089-43-3 SP - 15 Seiten PB - Deutsche Glastechnische Gesellschaft CY - Offenbach AN - OPUS4-7558 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Görner, Wolf A1 - Eichelbaum, Maik A1 - Matschat, Ralf A1 - Rademann, K. A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich T1 - Non-destructive investigation of composition, chemical properties and structure of materials by synchrotron radiation PY - 2006 SN - 0007-1137 VL - 48 IS - 9 SP - 540 EP - 544 PB - British Institute of Non-Destructive Testing CY - Northampton AN - OPUS4-14186 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Guerra, M. F. A1 - Calligaro, T. A1 - Radtke, Martin A1 - Reiche, I. A1 - Riesemeier, Heinrich T1 - Fingerprinting ancient gold by measuring Pt with spatially resolved high energy Sy-XRF N2 - Trace elements of ancient gold such as Pt, give fundamental information on the circulation of the metal in the past. In the case of objects from the cultural heritage, the determination of trace elements requires non-destructive point analysis in general. These conditions and the need of good detection limits restrain the number of applicable analytical techniques. After the development of a PIXE set-up with a selective Cu or Zn filter of 75 µm and of a PIXE-XRF set-up using a primary target of As, we tested the possibilities of spatially resolved Sy-XRF to determine Pt in gold alloys. With a Zn filter, PIXE showed a detection limit of 1000 ppm in gold while PIXE-XRF lowers this detection limit down to 80 ppm. This last value being constrained by the resonant Raman effect produced on gold. In order to improve the detection limit of Pt keeping the non-destructiveness and access to point analysis, we developed an analytical protocol for XRF with synchrotron radiation at BESSY II, using the BAMline set-up. The L-lines of Pt were excited by a beam of energy above and below 11.564 keV and measured using a Si(Li) detector with a 50 µm Cu filter. A µ-beam of 100–250 µm2 was used according to the size of the sample. The determination of the Pt content in the samples was carried out by Monte-Carlo simulation and subtraction of Au and Pt spectra obtained on pure standards. The limit of detection for Pt of 20 ppm was determined by using certified standards. The detection limits of a small set of other characteristic elements of gold were also measured using an incident energy of 33 keV. KW - PIXE-XRF KW - Sy-XRF KW - Pt KW - Ancient gold KW - Fingerprinting PY - 2005 DO - https://doi.org/10.1016/j.nimb.2005.06.150 SN - 0168-583X SN - 1872-9584 VL - 240 IS - 1-2 SP - 505 EP - 511 PB - Elsevier CY - Amsterdam AN - OPUS4-14236 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin A1 - Riesemeier, Heinrich A1 - Strub, Erik A1 - Guerra, M. F. A1 - Reiche, I. T1 - Analysis of trace elements in gold alloys by SR-XRF at high energy at the BAMline T2 - Ecaart 9 (European conference on accelerators in applied research and technology) CY - Florence, Italy DA - 2007-09-03 PY - 2007 AN - OPUS4-16399 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich A1 - Strub, E. A1 - Guerra, M.-F. A1 - Reiche, I. T1 - SR-XRF analysis of trace amounts of Pt in gold alloys T2 - European Conference on X-ray Spectrometry CY - Dubrovnik, Croatia DA - 2008-06-16 PY - 2008 AN - OPUS4-17845 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin A1 - Buzanich, Günter A1 - Curado, Jessica A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich A1 - Scharf, O. T1 - Slicing - A New Method For Non Destructive 3D Elemental Sensitive Characterization Of Materials T2 - International Congress on X-Ray Optics and Microanalysis CY - Hamburg, Germany DA - 2013-09-02 PY - 2013 AN - OPUS4-29897 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Buzanich, Günter A1 - Fittschen, U.E.A A1 - Menzel, M. A1 - Scharf, O. A1 - Horntrich, C. A1 - Montoya, V. A1 - McIntosh, K. A1 - Havrilla, G.J. A1 - Streli, C. T1 - THE IDEAL SPECIMENT FOR TOTAL REFLECTION X-RAY FLUORESCENCE (TXRF) ANALYSIS: RESULTS FROM SIMULATIONS AND EXPERIMENTAL EVALUATION T2 - Denver X-Ray Conference CY - Westminster, CO, USA DA - 2013-08-05 PY - 2013 AN - OPUS4-29869 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin T1 - "Golden Past and Future" - Applications of Synchrotron Radiation for Cultural Heritage T2 - 1st INTERNATIONAL CONFERENCE ON INNOVATION IN ART RESEARCH AND TECHNOLOGY INART´13 CY - Evora, Portugal DA - 2013-07-10 PY - 2013 AN - OPUS4-29862 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin A1 - Krämer, M. A1 - Dietsch, R. A1 - Falkenberg, G. A1 - Beckhoff, B. A1 - Hönicke, P. A1 - Fittschen, U.E.A. A1 - Simon, R. T1 - NEW INVESTIGATIONS WITH NANOGRAM MULTI-ELEMENT REFERENCE SAMPLES FOR XRF AND TXRF ANALYSIS T2 - Denver X-Ray Conference CY - Westminster, CO, USA DA - 2013-08-05 PY - 2013 AN - OPUS4-29864 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Reifschneider, O. A1 - Vennemann, A. A1 - Buzanich, Günter A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich A1 - Hogeback, J A1 - Köppen, C. A1 - Großgarten, M. A1 - Sperling, M. A1 - Wiemann, M. A1 - Karst, U. T1 - Revealing Silver Nanoparticle Uptake by Macrophages Using SR-μXRF and LA-ICP-MS N2 - To better study the impact of nanoparticles on both in vitro and in vivo models, tissue distribution and cellular doses need to be described more closely. Here silver nanoparticles were visualized in alveolar macrophages by means of synchrotron radiation micro X-ray fluorescence spectroscopy (SR-μXRF) with high spatial resolution of 3 × 3 μm2. For the spatial allocation of silver signals to cells and tissue structures, additional elemental labeling was carried out by staining with eosin, which binds to protein and can be detected as bromine signal with SR-μXRF. The method was compatible with immunostaining of macrophage antigens. We found that the silver distribution obtained with SR-μXRF was largely congruent with distribution maps from a subsequent laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) of the same tissue sites. The study shows a predominant, though not exclusive uptake of silver into alveolar macrophages in the rat lung, which can be modeled by a similar uptake in cultured alveolar macrophages. Advantages and limitations of the different strategies for measuring nanoparticle uptake at the single cell level are discussed. KW - Synchrotron KW - BAMline KW - XRF KW - Nanoparticle KW - Macrophagen PY - 2020 DO - https://doi.org/10.1021/acs.chemrestox.9b00507 VL - 33 IS - 5 SP - 1250 EP - 1255 PB - American Chemical Society AN - OPUS4-50855 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin T1 - Röntgenfluoreszenzanalyse mit Synchrotronstrahlung an der Bundesanstalt für Materialforschung und -prüfung (BAM), Berlin T2 - Seminar: "Strahlenphysikalische Anwendungen in Technik und Medizin" CY - Wien, Österreich DA - 2015-01-14 PY - 2015 AN - OPUS4-34014 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - de Oliveira Guilherme Buzanich, Ana A1 - Kulow, Anicó A1 - Kabelitz, Anke A1 - Grunewald, C. A1 - Seidel, R. A1 - Chapartegui-Arias, Ander A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Emmerling, Franziska A1 - Beyer, S. T1 - Observation of early ZIF-8 crystallization stages with X-ray absorption spectroscopy N2 - The present study investigates early stages of ZIF-8 crystallization up to 5 minutes post mixing of precursor solutions. Dispersive X-ray Absorption Spectroscopy (DXAS) provides a refined understanding of the evolution of the coordination environment during ZIF-8 crystallization. Linear Combination Fiting (LCF) suggests tetrakis(1-methylimidazole)zinc2+ to be a suitable and stable mononuclear structure analogue for some early stage ZIF-8 intermediates. Our results pave the way for more detailed studies on physico-chemical aspects of ZIF-8 crystallization to better control tailoring ZIF-8 materials for specific applications. KW - In-situ KW - XANES KW - ZIF-8 KW - Crystallization PY - 2020 DO - https://doi.org/10.1039/D0SM01356K SN - 1744-6848 VL - 17 IS - 2 SP - 331 EP - 334 PB - Royal Scociety of Chemistry AN - OPUS4-51723 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - de Oliveira Guilherme Buzanich, Ana A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich A1 - Emmerling, Franziska ED - de Oliveira Guilherme Buzanich, Ana ED - Strange, R. W. T1 - Time- and spatial-resolved XAFS spectroscopy in a single shot: new analytical possibilities for in situ material characterization N2 - A new concept that comprises both time- and lateral-resolved X-ray absorption fine-structure information simultaneously in a single shot is presented. This uncomplicated set-up was tested at the BAMline at BESSY-II (Berlin, Germany). The primary broadband beam was generated by a double multilayer monochromator. The transmitted beam through the sample is diffracted by a convexly bent Si (111) crystal, producing a divergent beam. This, in turn, is collected by either an energy-sensitive area detector, the so-called color X-ray camera, or by an area-sensitive detector based on a CCD camera, in θ–2θ geometry. The first tests were performed with thin metal foils and some iron oxide mixtures. A time resolution of lower than 1 s together with a spatial resolution in one dimension of at least 50 mm is achieved. KW - Single-shot XAFS KW - Time resolution PY - 2016 UR - http://scripts.iucr.org/cgi-bin/paper?S1600577516003969 DO - https://doi.org/10.1107/S1600577516003969 SN - 1600-5775 VL - 23 SP - 769 EP - 776 PB - International Union of Crystallography CY - Liverpool, UK AN - OPUS4-35903 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Radtke, Martin A1 - Reiche, I. A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich A1 - Guerra, M.F. T1 - Beyond the Great Wall: Gold of the silk roads and the first empire of the Steppes N2 - Fingerprinting ancient gold work requires the use of nondestructive techniques with high spatial resolution (down to 25 µm) and good detection limits (micrograms per gram level). In this work experimental setups and protocols for synchrotron radiation induced X-ray fluorescence (SRXRF) at the BAMline of the Berlin electron storage ring company for synchrotron radiation (BESSY) in Berlin for the measurement of characteristic trace elements of gold are compared considering the difficulties, shown in previous works, connected to the quantification of Pt. The best experimental conditions and calculation methods were achieved by using an excitation energy of 11.58 keV, a silicon drift chamber detector (SDD) detector, and pure element reference standards. A detection limit of 3 µg/g has been reached. This newly developed method was successfully applied to provenancing the Xiongnu gold from the Gol Mod necropolis, excavated under the aegis of the United Nations Educational, Scientific and Cultural Organization (UNESCO). The composition of the base alloys and the presence of Pt and Sn showed that, contrary to what is expected, the gold foils from the first powerful empire of the steppes along the Great Wall were produced with alluvial gold from local placer deposits located in Zaamar, Boroo, and in the Selenga River. KW - Synchrotron radiation KW - X-ray fluorescence KW - Limit of detection KW - Platinum KW - Silicon drift detector KW - SR-microXRF KW - Elemental imaging KW - Gold PY - 2013 DO - https://doi.org/10.1021/ac3025416 SN - 0003-2700 SN - 1520-6882 VL - 85 IS - 3 SP - 1650 EP - 1656 PB - American Chemical Society CY - Washington, DC AN - OPUS4-30224 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Mans, C. A1 - Simons, C. A1 - Hanning, S. A1 - Janßen, A. A1 - Alber, D. A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Bühler, A. A1 - Kreyenschmidt, M. T1 - New polymeric candidate reference materials for XRF and LA-ICP-MS - development and preliminary characterization N2 - A set of ten calibration materials based on acrylonitrile-butadiene-styrene terpolymer (ABS) containing the elements Br, Pb, Cd, Cr, and Hg was produced in order to control polymer samples in regard to the restriction on the use of certain hazardous substances (RoHS) directive. The materials were produced with respect to the special demands of X-ray fluorescence analysis (XRF) and inductively coupled plasma mass spectrometry in combination with laser ablation (LA-ICP-MS). The mass fractions of all elements were 0-1500 mg/kg and the materials were produced as granulates and solid discs with a diameter of 40 mm and thicknesses of 1, 2, and 6 mm. It could be shown that the signals measured by XRF strongly depend on the thickness of polymeric samples. Macroscopic homogeneity was assessed with XRF measuring a total of 180 samples. The microscopic homogeneities were determined for a material with average elemental mass fractions with the aid of synchrotron radiation (SR) µ-XRF and LA-ICP-MS. Sufficient macroscopic and microscopic homogeneities for all elements could be achieved. It was observed that organic additives show a better homogeneity than oxides. XRF and LA-ICP-MS were successfully calibrated with the new materials. Limits of detection were in the range of 0.4-22 mg/kg for XRF and 2.3-26.8 mg/kg for LA-ICP-MS. The materials are considered as candidate reference materials (RM) by the Federal Institute of Materials Research and Testing (BAM, Germany). KW - XRF KW - LA.ICP-MS Plastics KW - RoHS KW - CRM PY - 2009 DO - https://doi.org/10.1002/xrs.1120 SN - 0049-8246 VL - 38 IS - 1 SP - 52 EP - 57 PB - Wiley CY - Chichester AN - OPUS4-18681 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin A1 - Scharf, O. A1 - Reinholz, Uwe A1 - Bjeoumikova, S. A1 - Wedell, R. A1 - Soltau, H. A1 - Gubzhokov, Renat A1 - Riesemeier, Heinrich A1 - Langhoff, N. A1 - Ihle, S. T1 - First images of a colour X-ray camera, a detector with high resolution in energy and space T2 - Technart 2011 CY - Berlin, Germany DA - 2011-04-26 PY - 2011 AN - OPUS4-23082 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin T1 - Röntgenfluoreszenzanalyse mit Synchrotronstrahlung an derr Bundesanstalt für Materialforschung und -prüfung (BAM), Berlin T2 - Seminar: Strahlenphysikalische Anwendungen in Technik und Medizin CY - Vienna, Austria DA - 2010-01-13 PY - 2010 AN - OPUS4-23261 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich T1 - Synchrotronstrahlung für die Untersuchung von Kunstobjekten T2 - DGZfP Arbeitskreis Dresden CY - Dresden, Germany DA - 2010-12-09 PY - 2010 AN - OPUS4-23264 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Rodrigues, M. A1 - Cappa, F. A1 - Schreiner, M. A1 - Ferloni, P. A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Woytek, B. A1 - Alram, M. T1 - Further metallurgical analyses on silver coins of Trajan (AD 98-117) N2 - Within an interdisciplinary project, preliminary results of which were published in 2007, a group of 65 silver coins (denarii) of Trajan, evenly distributed over the entire span of his reign (2nd to 6th consulate), as well as 3 coins from the reign of his predecessor, the emperor Nerva (AD 96–98), had been acquired on the coin market. These pieces could be cross-sectioned in order to carry out analyses. Measurements were performed with µ-XRF and µ-SRXRF to check the fineness of the denarius alloy as well as to investigate if the coins of the different consulates showed distinct traits concerning the main impurities which could suggest a change of ore sources. Furthermore, it was examined whether the influx of precious metals into the Roman treasury after Trajan's Dacian campaigns (AD 101/102 and 105/106) could have had any repercussions on the composition of the denarius alloy; comparative data was provided by the analysis of nine imitations of Roman Republican denarii presumably struck in Dacia. Documentation of the cross-sections was performed with SEM/EDX in order to clarify details concerning the specific microstructure of the coins. An enrichment of Ag of approx. 100 to 200 µm in the near surface regions of most of the coins could be observed, which is due to corrosion effects. Previous metallographic analyses done by several scholars had been inadequate to clarify the central numismatic and economic questions. With the presented analyses, it was possible to correct the results of the earlier research and to provide, for the first time, a secure basis of data for the investigation of the development of the silver alloy used for denarii in Trajan's reign. PY - 2011 DO - https://doi.org/10.1039/c0ja00252f SN - 0267-9477 SN - 1364-5544 VL - 26 IS - 5 SP - 873 EP - 1100 PB - Royal Society of Chemistry CY - London AN - OPUS4-23623 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin T1 - Materialforschung an der BAMline T2 - Seminar Strahlenphysikalische Anwendungen in Technik und Medizin CY - Vienna, Austria DA - 2010-01-13 PY - 2010 AN - OPUS4-23605 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Constantinescu, B. A1 - Vasilescu, A. A1 - Radtke, Martin A1 - Reinholz, Uwe T1 - Micro-SR-XRF studies for archaeological gold identification - the case of carpathian gold and romanian museal objects N2 - In the determination of the provenance of gold in archaeological artifacts, trace elements are more significant than the main components. Several minute fragments of natural Carpathian gold-placer and primary-and some very small (a few milligrams) fragments of archaeological items were studied using micro Synchrotron Radiation X-Ray Fluorescence (micro SR-XRF) at the BESSY Synchrotron Facility in Berlin, Germany. The goal of the study was to identify the trace elements characterizing Carpathian gold, looking especially at Sn, Sb, Pb and Te, and to determine if the gold in the archaeological items is native or refined. Applications to the authentication and provenance of nine Dacian gold bracelets, koson coins and two Bronze Age items are presented. KW - Gold KW - Provenance KW - Archeometry KW - Sy-XRF PY - 2010 DO - https://doi.org/10.1007/s00339-010-5624-1 SN - 0947-8396 VL - 99 IS - 2 SP - 383 EP - 389 PB - Springer CY - Berlin AN - OPUS4-21395 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gauert, C. A1 - Schannor, M. A1 - Hecht, L. A1 - Radtke, Martin A1 - Reinholz, Uwe T1 - A comparison of in situ analytical methods for trace element measurement in gold samples from various South African gold deposits N2 - Trace element concentrations in gold grains from various geological units in South Africa were measured in situ by field emission-electron probe microanalysis (FE-EPMA), laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) and synchrotron micro X-ray fluorescence spectroscopy (SR-µ-XRF). This study assesses the accuracy, precision and detection limits of these mostly non-destructive analytical methods using certified reference materials and discusses their application in natural sample measurement. FE-EPMA point analyses yielded reproducible and discernible concentrations for Au and trace concentrations of S, Cu, Ti, Hg, Fe and Ni, with detection limits well below the actual concentrations in the gold. LA-ICP-MS analyses required larger gold particles (> 60 µm) to avoid contamination during measurement. Elements that measured above detection limits included Ag, Cu, Ti, Fe, Pt, Pd, Mn, Cr, Ni, Sn, Hg, Pb, As and Te, which can be used for geochemical characterisation and gold fingerprinting. Although LA-ICP-MS measurements had lower detection limits, precision was lower than FE-EPMA and SR-µ-XRF. The higher variability in absolute values measured by LA-ICP-MS, possibly due to micro-inclusions, had to be critically assessed. Non-destructive point analyses of gold alloys by SR-µ-XRF revealed Ag, Fe, Cu, Ni, Pb, Ti, Sb, U, Cr, Co, As, Y and Zr in the various gold samples. Detection limits were mostly lower than those for elements measured by FE-EPMA, but higher than those for elements measured by LA-ICP-MS. N2 - Les concentrations en éléments traces de grains d'or provenant de différentes unités géologiques d'Afrique du Sud ont été mesurées in situ par microsonde électronique à émission de champ (FE-EPMA), spectrométrie de masse couplée à une source plasma et un système d'ablation laser (LA-ICP-MS) et micro spectroscopie de fluorescence des rayons X au Synchrotron (SR-µ-XRF). Cette étude évalue l'exactitude, la précision et les limites de détection de ces méthodes d'analyse pour la plupart non-destructives en utilisant des matériaux de référence certifiés, et discute de leur application dans les mesures sur échantillon naturel. Les points d'analyses FE-EPMA ont fournis des concentrations reproductibles et discernables pour l'Au et des concentrations en traces de S, Cu, Ti, Hg, Fe et Ni, avec des limites de détection bien inférieures aux concentrations réelles dans l'or. Les analyses LA-ICP-MS ont nécessitées des particules d'or de plus grande taille (> 60 µm) pour éviter toute contamination pendant la mesure. Les éléments mesurés au-dessus des limites de détection inclus Ag, Cu, Ti, Fe, Pt, Pd, Mn, Cr, Ni, Sn, Hg, Pb, A et Te, qui peuvent être utilisés pour les caractérisations géochimique et le «fingerprinting» de l'or. Bien que les mesures LA-ICP-MS aient des limites de détection plus basses, la précision est inférieure par rapport à celles de la microsonde FE et de la SR-µ-XRF. La plus grande variabilité des valeurs absolues mesurées par LA-ICP-MS, probablement reliée à la présence de micro-inclusions, a du être évaluée de manière critique. Les points d'analyse non-destructifs des alliages d'or par SR-µ-XRF ont révélés la présence de Ag, Fe, Cu, Ni, Pb, Ti, Sb, U, Cr, Co, As, Y et Zr dans les différents échantillons. Les limites de détection ont été pour la plupart inférieures à celles des éléments mesurés par FE-EPMA, mais supérieures à celles des éléments mesurés par LA-ICP-MS. KW - Trace elements KW - Gold KW - FE-EPMA KW - LA-ICP-MS KW - SR-µ-XRF KW - Precision KW - Précision KW - Comparison of techniques KW - Éléments traces PY - 2016 DO - https://doi.org/10.1111/j.1751-908X.2015.00362.x SN - 1639-4488 SN - 1751-908X VL - 40 IS - 2 SP - 267 EP - 289 PB - Blackwell CY - Oxford AN - OPUS4-34882 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin A1 - Menzel, M. A1 - Flittschen, U. E. A. A1 - Scharf, O. A1 - Nowak, S. A1 - Reinholz, Uwe A1 - Buzanich, Günter A1 - Montoya, V. A1 - McIntosh, K. A1 - Havrilla, G. J. A1 - Hischenhuber, P. A1 - Streli, C. T1 - Shading Effects in SR-TXRF: Calcullations and Experimental Visualization using a Color X-ray Camera T2 - Denver X-ray Conference CY - BIG SKY RESORT, BIG SKY, MONTANA, USA DA - 2014-07-28 PY - 2014 AN - OPUS4-32386 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin A1 - Buzanich, Günter A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich T1 - 3D and Beyond - Basics and Applications of the Color X-ray Camera T2 - Denver X-ray Conference CY - BIG SKY RESORT, BIG SKY, MONTana, USA DA - 2014-07-28 PY - 2014 AN - OPUS4-32366 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin A1 - Buzanich, Günter A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich A1 - Scharf, O. T1 - Detection of platinum in gold with D2XRF T2 - SR2A 2014 CY - Paris (Frankreich) DA - 2014-09-09 PY - 2014 AN - OPUS4-32369 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin A1 - Fittschen, U. E. A. A1 - Menzel, M. A1 - Scharf, O. A1 - Nowak, S. A1 - Reinholz, Uwe A1 - Buzanich, Günter A1 - Montoya, V. A1 - McIntosh, K. T1 - Shading Effects in SR-TXRF: Calculations and Experimental Visualization using a Color X-ray Camera T2 - Denver X-ray Conference CY - BIG SKY RESORT, BIG SKY, MONTANA, USA DA - 2014-07-28 PY - 2014 AN - OPUS4-32371 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Tissot, I. A1 - Troalen, L.G. A1 - Manso, M. A1 - Ponting, M. A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Barreiros, M. A. A1 - Shaw, I. A1 - Carvalho, M.L. A1 - Guerra, M.F. T1 - A multi-analytical approach to gold in Ancient Egypt: Studies on provenance and corrosion N2 - Recent results from a three-year multi-disciplinary project on Ancient Egyptian gold jewellery revealed that items of jewellery from the Middle Kingdom to the New Kingdom were manufactured using a variety of alluvial gold alloys. These alloys cover a wide range of colours and the majority contain Platinum Group Elements inclusions. However, in all the gold foils analysed, these inclusions were found to be absent. In this work a selection of gilded wood and leather items and gold foil fragments, all from the excavations by John Garstang at Abydos (primarily from Middle Kingdom graves), were examined using Scanning Electron Microscopy-Energy Disperse Spectroscopy (SEM-EDS), X-Ray Fluorescence (µXRF), Particle Induced X-Ray Emission (µPIXE) and Double Dispersive X-Ray Fluorescence (D²XRF). The work allowed us to characterise the composition of the base-alloys and also to reveal the presence of Pt at trace levels, confirming the use of alluvial gold deposits. Corrosion products were also investigated in the foils where surface tarnish was visually observed. Results showed that the differences in the colour of corrosion observed for the foils are related not only to the thickness of the corrosion layer but also to a multi-layer structure containing the various corrosion products. KW - Gold KW - Egypt KW - PGE KW - Provenance KW - Corrosion KW - muXRF KW - muPIXE KW - D2XRF KW - SEM-EDS PY - 2015 DO - https://doi.org/10.1016/j.sab.2015.03.012 SN - 0584-8547 SN - 0038-6987 VL - 108 SP - 75 EP - 82 PB - Elsevier CY - Amsterdam AN - OPUS4-33155 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin A1 - de Oliveira Guilherme Buzanich, Ana A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich A1 - Scharf, o T1 - The colour X-ray camera – Basics and applications of a 2D X-ray detector N2 - The Color X-ray Camera CXC or SLcam® is an energy-resolving X-ray camera capable of energy- and space-resolved measurements. It consists of a high-speed CCD detector coupled to a polycapil-lary optic that conducts the X-ray photons from the probe to distinct pixels onto the detector. The camera is capable of fast acquisition of spatially and energy resolved fluorescence images. A dedicated software enables the acquisition and the online processing of the spectral data for all 69696 pixels, leading to a real-time visualization of the elements distribution in a sample. It was developed in a joint project with BAM, IFG Berlin and PN Sensors. In this contribution we will mainly discuss the use of the CXC at our beamline, the BAMline at BESSY II and imaging applications of the CXC from different areas, like biology and archaeometry. Additionally new developments for the use of the detector without optics, like wavelength dispersive detection or 1shot-XANES, will be presented. T2 - Seminar Strahlenphysikalische Anwendungen in Technik und Medizin CY - ATi Wien, Austria DA - 24.01.2018 KW - XRF KW - Synchrotron KW - BAMline PY - 2018 AN - OPUS4-46365 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Cakir, Cafer Tufan A1 - Bogoclu, Can A1 - Emmerling, Franziska A1 - Streli, Christina A1 - Guilherme Buzanich, Ana A1 - Radtke, Martin T1 - Machine learning for efficient grazing-exit x-ray absorption near edge structure spectroscopy analysis: Bayesian optimization approach N2 - In materials science, traditional techniques for analyzing layered structures are essential for obtaining information about local structure, electronic properties and chemical states. While valuable, these methods often require high vacuum environments and have limited depth profiling capabilities. The grazing exit x-ray absorption near-edge structure (GE-XANES) technique addresses these limitations by providing depth-resolved insight at ambient conditions, facilitating in situ material analysis without special sample preparation. However, GE-XANES is limited by long data acquisition times, which hinders its practicality for various applications. To overcome this, we have incorporated Bayesian optimization (BO) into the GE-XANES data acquisition process. This innovative approach potentially reduces measurement time by a factor of 50. We have used a standard GE-XANES experiment, which serve as reference, to validate the effectiveness and accuracy of the BO-informed experimental setup. Our results show that this optimized approach maintains data quality while significantly improving efficiency, making GE-XANES more accessible to a wider range of materials science applications. KW - Machine Learning KW - GE-XANES KW - Bayesian Optimization PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-603955 DO - https://doi.org/10.1088/2632-2153/ad4253 VL - 5 IS - 2 SP - 1 EP - 12 PB - IOP Publishing AN - OPUS4-60395 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Berger, Achim A1 - Görner, Wolf A1 - Merchel, Silke A1 - Procop, Mathias A1 - Radtke, Martin A1 - Riesemeier, Heinrich T1 - SY-XRF in certification of a reference material at the BAMline PY - 2003 UR - http://www.helmholtz-berlin.de/media/media/oea/web/pr_webseite/druckschriften/berichte/bessy/annualreport2002.pdf#page=311 SN - 0179-4159 SP - 311 EP - 312 PB - Berliner Elektronenspeicherring-Gesellschaft für Synchrotronstrahlung CY - Berlin AN - OPUS4-2492 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Berger, Achim A1 - Ecker, Klaus A1 - Görner, Wolf A1 - Merchel, Silke A1 - Procop, Mathias A1 - Radtke, Martin A1 - Riesemeier, Heinrich T1 - X-ray fluorescence analysis at the BAMline PY - 2002 UR - http://www.helmholtz-berlin.de/media/media/oea/web/pr_webseite/druckschriften/berichte/bessy/annualreport2001.pdf#page=253 SN - 0179-4159 SP - 253 EP - 254 PB - Berliner Elektronenspeicherring-Gesellschaft für Synchrotronstrahlung CY - Berlin AN - OPUS4-1322 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Menzel, M. A1 - Scharf, O. A1 - Novak, S. A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Hischenhuber, P. A1 - Buzanich, Günter A1 - Meyer, A. A1 - Lopez, V. A1 - McIntosh, K. A1 - Streli, C. A1 - Havrilla, G. A1 - Fittschen, U. T1 - Shading in TXRF: calculations and experimental validation using a color X-ray camera N2 - Absorption effects in total reflection X-ray fluorescence (TXRF) analysis are important to consider, especially if external calibration is to be applied. With a color X-ray camera (CXC), that enables spatially and energy resolved XRF analysis, the absorption of the primary beam was directly visualized for mL-droplets and an array of pL-droplets printed on a Si-wafer with drop-on-demand technology. As expected, deposits that are hit by the primary beam first shade subsequent droplets, leading to a diminished XRF signal. This shading effect was quantified with enhanced precision making use of sub-pixel analysis that improves the spatial resolution of the camera. The measured absorption was compared to simulated results using three different model calculations. It was found they match very well (average deviation < 10%). Thus errors in quantification due to absorption effects can be accounted for in a more accurate manner. KW - absorption KW - X-ray Fluorescence analysis PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-359000 DO - https://doi.org/10.1039/C5JA00127G IS - 10 SP - 2184 EP - 2193 PB - Royal Society of Chemistry CY - Cambridge AN - OPUS4-35900 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kabelitz, Anke A1 - de Oliveira Guilherme Buzanich, Ana A1 - Joester, Maike A1 - Reinholz, Uwe A1 - Radtke, Martin A1 - Bienert, Ralf A1 - Schulz, K. A1 - Schmack, R. A1 - Kraehnert, R. A1 - Emmerling, Franziska T1 - Time-resolved in situ studies on the formation mechanism of iron oxide nanoparticles using combined fast-XANES and SAXS N2 - The reaction of iron chlorides with an alkaline reagent is one of the most prominent methods for the synthesis of iron oxide nanoparticles. We studied the particle formation mechanism using triethanolamine as reactant and stabilizing agent. In situ fast-X-ray absorption near edge spectroscopy and small-angle X-ray scattering provide information on the oxidation state and the structural information at the same time. In situ data were complemented by ex situ transmission electron microscopy, wide-angle X-ray scattering and Raman analysis of the formed nanoparticles. The formation of maghemite nanoparticles (γ-Fe2O3) from ferric and ferrous chloride was investigated. Prior to the formation of these nanoparticles, the formation and conversion of intermediate phases (akaganeite, iron(II, III) hydroxides) was observed which undergoes a morphological and structural collapse. The thus formed small magnetite nanoparticles (Fe3O4) grow further and convert to maghemite with increasing reaction time. KW - oxidation state KW - structural information KW - maghemite PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-351376 DO - https://doi.org/10.1039/C5CE01585E SN - 1466-8033 VL - 17 IS - 44 SP - 8463 EP - 8470 CY - London, UK AN - OPUS4-35137 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - de Oliveira Guilherme Buzanich, Ana A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich A1 - Emmerling, Franziska T1 - Time- & spatial-resolved X-ray absorption fine structure (XAFS) spectroscopy in a single-shot – new analytical possibilities for in situ material characterization N2 - A new concept that comprises both time- and lateral-resolved X-ray absorption fine-structure information simultaneously in a single shot is presented. This uncomplicated set-up was tested at the BAMline at BESSY-II (Berlin, Germany). The primary broadband beam was generated by a double multilayer monochromator. The transmitted beam through the sample is diffracted by a convexly bent Si (111) crystal, producing a divergent beam. This, in turn, is collected by either an energy-sensitive area detector, the so-called color X-ray camera, or by an area-sensitive detector based on a CCD camera, in θ-2θ geometry. The first tests were performed with thin metal foils and some iron oxide mixtures. A time resolution of lower than 1 s together with a spatial resolution in one dimension of at least 50 µm is achieved. KW - Time resolution KW - Single-shot XAFS PY - 2016 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-370892 DO - https://doi.org/10.1107/S1600577516003969 SN - 1600-5775 IS - 23 SP - 769 EP - 776 PB - International Union of Crystallography CY - Chester, UK AN - OPUS4-37089 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Radtke, Martin A1 - Buzanich, Günter A1 - Curado, Jessica A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich A1 - Scharf, O. T1 - Slicing - a new method for non destructive 3D elemental sensitive characterization of materials N2 - Recent advances in synchrotron sources and detector technology have led to substantial improvements in spatial resolution and detection limits for X-ray fluorescence analysis (XRF). However, the non-destructive three-dimensional elemental sensitive characterization of samples remains a challenge. We demonstrate the use of the so-called 'Color X-ray Camera' (CXC) for 3D measurements for the first time. The excitation of the sample is realized with a thin sheet-beam. The stepwise movement of the sample allows getting the elemental distribution for each layer with one measurement. These layers can be combined to a full 3D dataset for each element afterwards. Since the information is collected layer by layer, there is no need to apply reconstruction techniques, which quite often are the reason for artifacts in the results achieved by computed tomography (CT). The field of applications is wide, as the 3D elemental distribution of a material contains clues to processes inside the samples from a variety of origins. The technique is of special interest and well suited for biological specimens, because their light matrix minimizes restricting absorption effects. Measurement examples of a hornet and the teeth of a Sorex araneus are shown. KW - SR-microXRF KW - 3D KW - CXC PY - 2014 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-324330 DO - https://doi.org/10.1039/c4ja00085d SN - 0267-9477 SN - 1364-5544 VL - 29 IS - 8 SP - 1339 EP - 1344 PB - Royal Society of Chemistry CY - London AN - OPUS4-32433 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hachmöller, O. A1 - de Oliveira Guilherme Buzanich, Ana A1 - Aichler, M. A1 - Radtke, Martin A1 - Dietrich, D. A1 - Schwamborn, K. A1 - Lutz, L. A1 - Werner, M. A1 - Sperling, M. A1 - Walch, A. A1 - Karst, U. T1 - Elemental bioimaging and speciation analysis for the investigation of Wilsons disease using μXRF and XANES N2 - A liver biopsy specimen from a Wilson’s disease (WD) patient was analyzed by means of micro-X-ray fluorescence (mXRF) spectroscopy to determine the elemental distribution. First, bench-top mXRF was utilized for a coarse scan of the sample under laboratory conditions. The resulting distribution maps of copper and iron enabled the determination of a region of interest (ROI) for further analysis. In order to obtain more detailed elemental information, this ROI was analyzed by synchrotron radiation (SR)-based mXRF with a beam size of 4 mm offering a resolution at the cellular level. Distribution maps of additional elements to copper and iron like zinc and manganese were obtained due to a higher sensitivity of SR-mXRF. In addition to this, X-ray absorption near edge structure spectroscopy (XANES) was performed to identify the oxidation states of copper in WD. This speciation analysis indicated a mixture of copper(I) and copper(II) within the WD liver tissue. KW - progressive hepatolenticular degeneration KW - mXRF Micro-X-ray fluorescence spectroscopy KW - XANES X-ray absorption near edge structure spectroscopy PY - 2016 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-360811 DO - https://doi.org/10.1039/C6MT00001K SN - 1756-5901 SN - 1756-591X PB - Royal Society of Chemistry CY - Cambridge AN - OPUS4-36081 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - INPR A1 - Nowak, S. H. A1 - Petric, M. A1 - Buchriegler, J. A1 - Bjeoumikhov, A. A1 - Bjeoumikhova, Z. A1 - von Borany, J. A1 - Munnik, F. A1 - Radtke, Martin A1 - Renno, A. D. A1 - Reinholz, Uwe A1 - Scharf, O. A1 - Tilgner, J. A1 - Wedell, R. T1 - Road to micron resolution with a color X-ray camera - Polycapillary optics characterization N2 - In a color X-ray camera spatial resolution is achieved by means of a polycapillary optic conducting X-ray photons from small regions on a sample to distinct energy dispersive pixels on a CCD matrix. At present, the resolution limit of color X-ray camera systems can go down to several microns and is mainly restricted by Pixel dimensions. The recent development of an efficient subpixel resolution algorithm allows a release from pixel size, limiting the resolution only to the quality of theoptics. In this work polycapillary properties that influence the spatial resolution are systematized and assessed both theoretically and experimentally. It is demonstrated that with the current technological Level reaching one micron resolution is challenging, but possible. KW - Color X-ray camera KW - Polycapillary optics PY - 2017 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-404404 DO - https://doi.org/10.48550/arXiv.1705.08939 SN - 2331-8422 SP - 1 EP - 11 PB - Cornell University CY - Ithaca, NY AN - OPUS4-40440 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Reiche, I. A1 - Berger, Achim A1 - Görner, Wolf A1 - Merchel, Silke A1 - Radtke, Martin A1 - Riederer, J. A1 - Riesemeier, Heinrich T1 - Dürer's chemischer Fingerprint - Untersuchungen mittels Synchrotron-induzierter Röntgenfluoreszenzanalyse T2 - 5. Erfurter Fachtage für Konservierung und Restaurierung CY - Erfurt, Germany DA - 2002-11-28 PY - 2002 AN - OPUS4-2123 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Reiche, I. A1 - Berger, Achim A1 - Buck, St. A1 - Görner, Wolf A1 - Ketelsen, Th. A1 - Merchel, Silke A1 - Radtke, Martin A1 - Riederer, J. A1 - Riesemeier, Heinrich T1 - BAMline meets Dürer and van Eyck - Multi-disciplinary investigation of Renaissance silver point drawings by µ-SR-XRF N2 - - http://www.bessy.de/publications/05.annual_reports/files/AnnualReport2002.pdf - PY - 2003 UR - http://www.helmholtz-berlin.de/media/media/oea/web/pr_webseite/druckschriften/berichte/bessy/annualreport2002.pdf#page=416 SN - 0179-4159 SP - 416 EP - 418 PB - Berliner Elektronenspeicherring-Gesellschaft für Synchrotronstrahlung CY - Berlin AN - OPUS4-2496 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Buzanich, Günter A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich A1 - Streli, C. T1 - Micro-X-ray absorption spectroscopy with compound refractive lenses N2 - A study regarding the possibility to use compound refractive lenses (CRLs) for X-ray absorption spectroscopy (XAS) was conducted. For XAS measurements the energy of the monochromatic incident beam has to be tuned over an energy range which is broader than the energy bandwidth of a CRL. To prove that µ-XAS with compound refractive lenses is possible, it had to be investigated how changes in the energy influence the beam parameters. This was done by tuning the energy around the nominal energy of the lens and recording images with a high resolution X-ray imaging setup. To investigate the changes in the spot size the scintillator was placed at the nominal focal distance and scans along the beam axis were performed. The effect on the photon flux of the incident beam due to absorption in the lens was investigated by performing XANES measurement on different reference materials with and without CRL. The results of these measurements using a CRL designed for 9 keV are shown and discussed. KW - Micro-XAS KW - Compound refractive lens PY - 2012 DO - https://doi.org/10.1039/c2ja30130j SN - 0267-9477 SN - 1364-5544 VL - 27 IS - 10 SP - 1803 EP - 1808 PB - Royal Society of Chemistry CY - London AN - OPUS4-26790 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Buzanich, Günter A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich A1 - Thünemann, Andreas A1 - Streli, C. T1 - Impurities in multicrystalline silicon wafers for solar cells detected by synchrotron micro-beam X-ray fluorescence analysis N2 - We report on the trace analysis of copper and iron impurities in multicrystalline silicon wafers with the microbeam X-ray fluorescence (µ-XRF) technique. The efficiency of solar cells, which are based on multicrystalline silicon wafers, is strongly influenced by minor contamination with metals such as copper and iron. Application of compound refractive lenses (CRLs) in µ-XRF allows versatile two-dimensional mapping of relevant contaminations and localization of their sites of deposition. In this context, the measured bulk average limit of detection (LOD) was one picogram of iron and copper per gram of silicon. We suggest that µ-XRF is a valuable tool for non-destructive spatial (3D) quantification of metal impurities in a wide range of materials and devices whose functioning could be critically affected by impurities. KW - X-ray micro beam KW - Compound refractive lens KW - Solar cell KW - Silicon impurities PY - 2012 DO - https://doi.org/10.1039/c2ja30188a SN - 0267-9477 SN - 1364-5544 VL - 27 IS - 11 SP - 1875 EP - 1881 PB - Royal Society of Chemistry CY - London AN - OPUS4-26791 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Grengg, C. A1 - Koraimann, G. A1 - Ukrainczyk, N. A1 - Rudic, O. A1 - Luschnig, S. A1 - Gluth, Gregor A1 - Radtke, Martin A1 - Dietzel, M. A1 - Mittermayr, F. T1 - Cu- and Zn-doped alkali activated mortar – Properties and durability in (bio)chemically aggressive wastewater environments N2 - Metakaolin-based alkali activated mortars (AAM) - with and without CuSO4·5H2O and ZnO addition (mass ratio Mn+/solid binder 0.08% to 1.7%) - were casted and exposed within an extensive long-term field campaign over the period of 20 months to a sewer basin, strongly affected by biogenic acid corrosion. (Un-)exposed AAM were tested regarding their physicochemical and microstructural properties, bioreceptivity and overall durability. Metal addition led to a retarding effect during alkali-activation reaction, as well as to an increase in open porosity of up to 3.0% and corresponding lower compressive strength of up to 10.9%. Reduced microbial colonization and diversity were observed on AAM with Cu, while Zn addition led to increased biodiversity. We propose that the observed higher durability of Cu-doped AAM is due to antibacterial effects and associated reduction of biogenic acid production, superseding overall negative effects of metal-dosage on physical material properties. Observed lower durability of Zn-doped AAM was related to combined negative physicochemical and microbial effects. KW - Microbially induced corrosion KW - Alkali-activated materials KW - Biogenic acid corrosion KW - Biogene Schwefelsäurekorrosion KW - MIC PY - 2021 DO - https://doi.org/10.1016/j.cemconres.2021.106541 SN - 0008-8846 VL - 149 SP - 1 EP - 15 PB - Elsevier CY - Oxford AN - OPUS4-53070 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Fittschen, U. A1 - de Oliveira Guilherme Buzanich, Ana A1 - Böttger, S. A1 - Rosenberg, D. A1 - Menzel, M. A1 - Jensen, W. A1 - Busker, M. A1 - Gotlib, Z. A1 - Radtke, Martin A1 - Riesemeier, Heinrich A1 - Wobrauschek, P. A1 - Streli, C. ED - de Oliveira Guilherme Buzanich, Ana T1 - A setup for synchrotron-radiation-induced total reflection X-ray fluorescence and X-ray absorption near-edge structure recently commissioned at BESSY II BAMline N2 - An automatic sample changer chamber for total reflection X-ray fluorescence (TXRF) and X-ray absorption near-edge structure (XANES) analysis in TXRF geometry was successfully set up at the BAMline at BESSY II. TXRF and TXRF-XANES are valuable tools for elemental determination and speciation, especially where sample amounts are limited (<1 mg) and concentrations are low (ng ml⁻¹ to μg ml⁻¹). TXRF requires a well defined geometry regarding the reflecting surface of a sample carrier and the synchrotron beam. The newly installed chamber allows for reliable sample positioning, remote sample changing and evacuation of the fluorescence beam path. The chamber was successfully used showing accurate determination of elemental amounts in the certified reference material NISTwater 1640. Low limits of detection of less than 100 fg absolute (10 pg ml⁻¹) for Ni were found. TXRF-XANES on different Re species was applied. An unknown species of Re was found to be Re in the +7 oxidation state. KW - TXRF KW - TXRF-XANES KW - Sample changer KW - BAMline KW - Re-XANES PY - 2016 DO - https://doi.org/10.1107/S1600577516001995 SN - 1600-5775 VL - 23 IS - 3 SP - 820 EP - 824 PB - International Union of Crystallography AN - OPUS4-38656 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Curado, Jessica A1 - Radtke, Martin A1 - Buzanich, Günter A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich A1 - Guttler, R.A.S. A1 - Rizzutto, M.A. T1 - μ-SRXRF characterization of Brazilian emeralds N2 - The aim of the present study is to characterize emeralds from different mines of Brazil by using Synchrotron Radiation X-ray Fluorescence Microanalysis (µ-SRXRF). The advantage of this technique is that we can analyze a homogeneous, inclusion free area of the stone with the microbeam to distinguish the elemental fingerprint according to the provenance of the emerald. A total of 47 samples belonging to 5 different Brazilian mines were studied in this work and 28 elements were identified. By means of Principal Component Analysis (PCA) it is possible to build different groups according to the provenance of the stones, which allows to assign samples of unknown origin to the according mine. T2 - 22nd International congress on X-ray optics and microanalysis CY - Hamburg, Germany DA - 02.09.2013 KW - µ-SRXRF KW - BAMline KW - Emeralds KW - Geoscience PY - 2014 DO - https://doi.org/10.1088/1742-6596/499/1/012016 SN - 1742-6588 SN - 1742-6596 VL - 499 SP - 012016-1 EP - 012016-5 PB - IOP Publ. CY - Bristol, UK AN - OPUS4-30541 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Strub, Erik A1 - Plarre, Rüdiger A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich A1 - Schoknecht, Ute A1 - Urban, Klaus A1 - Jüngel, P. T1 - Determination of Cr(VI) in wood specimen: A XANES study at the Cr K edge N2 - The content of chromium in different oxidation states in chromium-treated wood was studied with XANES (X-ray absorption near-edge structure) measurements at the Cr K absorption edge. It could be shown that wood samples treated with Cr(VI) (pine and beech) did still contain a measurable content of Cr(VI) after four weeks conditioning. If such wood samples were heat exposed for 2 h with 135 °C prior conditioning, Cr(VI) was no longer detected by XANES, indicating a complete reduction to chromium (III). KW - X-ray spectroscopy KW - XANES KW - XAS KW - XRF KW - Specifikation KW - Reduction PY - 2008 DO - https://doi.org/10.1016/j.nimb.2008.03.011 SN - 0168-583X SN - 1872-9584 VL - 266 IS - 10 SP - 2405 EP - 2407 PB - Elsevier CY - Amsterdam AN - OPUS4-17555 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Constantinescu, B. A1 - Bugoi, R. A1 - Cojocaru, V. A1 - Radtke, Martin A1 - Calligaro, T. A1 - Salomon, J. A1 - Pichon, L. A1 - Röhrs, S. A1 - Ceccato, D. A1 - Oberländer-Târnoveanu, E. A1 - Ionescu, C. A1 - Pop, D. T1 - Dacian bracelets and Transylvanian gold: ancient history and modern analyses KW - SRXRF KW - Gold KW - Archaeometrie KW - Authentication KW - Provenance KW - XRF KW - Micro-PIXE KW - Micro SR-XRF KW - Or KW - Authentification KW - FX PY - 2009 SN - 0399-1237 VL - 33 SP - 221 EP - 225 PB - Groupe CY - Rennes AN - OPUS4-23172 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wolff, Timo A1 - Hahn, Oliver A1 - Merchel, Silke A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Denker, A. T1 - Four non-destructive X-Ray methods analyzing corroded coins: A self-critical comparison T2 - Workshop Synchrotron Radiation in Art and Archaeology 2006 CY - Berlin, Germany DA - 2006-09-27 PY - 2006 AN - OPUS4-14229 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Fittschen, U.E.A. A1 - Menzel, M. A1 - Scharf, O. A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Buzanich, Günter A1 - Lopez, V.M. A1 - McIntosh, K. A1 - Streli, C. A1 - Havrilla, G.J. T1 - Observation of X-ray shadings in synchrotron radiation-total reflection X-ray fluorescence using a color X-ray camera N2 - Absorption effects and the impact of specimen shape on TXRF analysis has been discussed intensively. Model calculations indicated that ring shaped specimens should give better results in terms of higher counts per mass signals than filled rectangle or circle shaped specimens. One major reason for the difference in signal is shading effects. Full field micro-XRF with a color X-ray camera (CXC) was used to investigate shading, which occurs when working with small angles of excitation as in TXRF. The device allows monitoring the illuminated parts of the sample and the shaded parts at the same time. It is expected that sample material hit first by the primary beam shade material behind it. Using the CXC shading could be directly visualized for the high concentration specimens. In order to compare the experimental results with calculation of the shading effect the generation of controlled specimens is crucial. This was achieved by 'drop on demand' technology. It allows generating uniform, microscopic deposits of elements. The experimentally measured shadings match well with those expected from calculation. KW - TXRF KW - Full field micro-XRF KW - Color X-ray camera PY - 2014 DO - https://doi.org/10.1016/j.sab.2014.06.025 SN - 0584-8547 SN - 0038-6987 VL - 99 SP - 179 EP - 184 PB - Elsevier CY - Amsterdam AN - OPUS4-31180 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Strub, Erik A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich A1 - Reznikova, E. T1 - Measurements with compound refractive lenses at the "BAMline" N2 - A set of compound refractive lenses (CRLs), mounted on a silicon wafer, was obtained from the Institut für Mikrostrukturtechnik Karlsruhe. The CRLs were characterized at the BAMline at the synchrotron BESSYII in Berlin. It could be demonstrated that beam diameters below 1 µm can be obtained. The beam size accepted by the lenses is (140 × 140) µm2, thus the intensity gain in the micrometer spot, including absorption, is about 15,000. It is possible to switch between different beam energies within a few minutes. First results of scans and the application of the lenses for MicroXANES (X-ray absorption near-edge structure) measurements are presented in this paper. Also, the possibility of MicroEXAFS (extended X-ray absorption fine structure) measurements is discussed. KW - X-ray optics KW - XANES KW - EXAFS KW - XAS KW - XRF KW - Speciation PY - 2008 DO - https://doi.org/10.1016/j.nimb.2008.02.057 SN - 0168-583X SN - 1872-9584 VL - 266 IS - 10 SP - 2165 EP - 2168 PB - Elsevier CY - Amsterdam AN - OPUS4-17554 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Constantinescu, B. A1 - Oberländer-Târnoveanu, E. A1 - Bugoi, R. A1 - Cojocaru, V. A1 - Radtke, Martin T1 - The Sarmizegetusa bracelets N2 - We present the authentication and analysis of these beautiful Dacian bracelets of the first century BC, originally pillaged by treasure hunters and recovered thanks to an international crime chase. They were originally fashioned from gold panned from the rivers or dug from the mines of Transylvania and hammered into the form of coiled snakes. The lack of context is the greatest loss, but a votive purpose is likely given their proximity to the great sacred centre at Sarmizegetusa Regia. KW - Romania KW - Sarmizegetusa KW - Dacian KW - First century BC KW - Gold KW - Bracelets KW - Hoard KW - Sacred centre KW - World heritage site PY - 2010 UR - http://antiquity.ac.uk/ant/084/ant0841028.htm SN - 0003-598x VL - 84 SP - 1028 EP - 1042 PB - Univ. Press CY - Oxford AN - OPUS4-23169 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Maack, Stefan A1 - Bertovic, Marija A1 - Radtke, Martin A1 - et al., ED - Wahlster, W. ED - Winterhalter, C. T1 - Deutsche Normungsroadmap künstliche Intelligenz N2 - Rund ein Jahr haben DIN und DKE in einem gemeinsamen Projekt mit dem Bundesministerium für Wirtschaft und Energie und zusammen mit ca. 300 Fachleuten aus Wirtschaft, Wissenschaft, öffentlicher Hand und Zivilgesellschaft an der Normungsroadmap Künstliche Intelligenz gearbeitet. Eine hochrangige Steuerungsgruppe unter dem Vorsitz von Prof. Wolfgang Wahlster hat die Erarbeitung koordiniert und begleitet. Ziel der Roadmap ist die frühzeitige Entwicklung eines Handlungsrahmens für die Normung und Standardisierung, der die internationale Wettbewerbsfähigkeit der deutschen Wirtschaft unterstützt und europäische Wertmaßstäbe auf die internationale Ebene hebt. KW - Künstliche Intelligenz KW - Normung KW - Roadmap PY - 2020 UR - https://www.din.de/resource/blob/772438/ecb20518d982843c3f8b0cd106f13881/normungsroadmap-ki-data.pdf VL - 2020 SP - 1 EP - 232 PB - Deutsches Institut für Normung (DIN) CY - Berlin ET - 1. AN - OPUS4-51733 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - C. Pardo Pérez, L. A1 - Arndt, A. A1 - Stojkovikj, S. A1 - Y. Ahmet, I. A1 - T. Arens,, J. A1 - Dattila, F. A1 - Wendt, R. A1 - de Oliveira Guilherme Buzanich, Ana A1 - Radtke, Martin A1 - Davies, V. A1 - Höflich, K. A1 - Köhnen, E. A1 - Tockhorn, P. A1 - Golnak, R. A1 - Xiao, J. A1 - Schuck, G. A1 - Wollgarten, M. A1 - López, N. A1 - T. Mayer, M. T1 - Determining Structure-Activity Relationships in Oxide Derived CuSn Catalysts During CO2 Electroreduction Using X-Ray Spectroscopy N2 - The development of earth-abundant catalysts for selective electrochemical CO2 conversion is a central challenge. Cu-Sn bimetallic catalysts can yield selective CO2 reduction toward either CO or formate. This study presents oxide-derived Cu-Sn catalysts tunable for either product and seeks to understand the synergetic effects between Cu and Sn causing these selectivity trends. The materials undergo significant transformations under CO2 reduction conditions, and their dynamic bulk and surface structures are revealed by correlating observations from multiple methods—X-ray absorption spectroscopy for in situ study, and quasi in situ X-ray photoelectron spectroscopy for surface sensitivity. For both types of catalysts, Cu transforms to metallic Cu0 under reaction conditions. However, the Sn speciation and content differ significantly between the catalyst types: the CO-selective catalysts exhibit a surface Sn content of 13 at. % predominantly present as oxidized Sn, while the formate-selective catalysts display an Sn content of ≈70 at. % consisting of both metallic Sn0 and Sn oxide species. Density functional theory simulations suggest that Snδ+ sites weaken CO adsorption, thereby enhancing CO selectivity, while Sn0 sites hinder H adsorption and promote formate production. This study reveals the complex dependence of catalyst structure, composition, and speciation with electrochemical bias in bimetallic Cu catalysts. KW - Electrochemical CO2 conversion KW - Cu catalysts KW - X-ray absorption spectroscopy PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-547116 DO - https://doi.org/10.1002/aenm.202103328 SN - 1614-6832 VL - 12 IS - 5 SP - 2103328 PB - Wiley-VCH GmbH AN - OPUS4-54711 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Reiche, I. A1 - Muller, K. A1 - Alberic, M. A1 - Scharf, O. A1 - Wahning, A. A1 - Bjeoumikhov, A. A1 - Radtke, Martin A1 - Simon, R. T1 - Discovering vanished paints and naturally formed gold nanoparticles on 2800 years old Phoenician ivories using SR-FF-microXRF with the color X-ray camera N2 - Phoenician ivory objects (8th century B.C., Syria) from the collections of the Badisches Landesmuseum, Karlsruhe, Germany, have been studied with full field X-ray fluorescence microimaging, using synchrotron radiation (SR-FF-microXRF). The innovative Color X-ray Camera (CXC), a full-field detection device (SLcam), was used at the X-ray fluorescence beamline of the ANKA synchrotron facility (ANKA-FLUO, KIT, Karlsruhe, Germany) to noninvasively study trace metal distributions at the surface of the archeological ivory objects. The outstanding strength of the imaging technique with the CXC is the capability to record the full XRF spectrum with a spatial resolution of 48 µm on a zone of a size of 11.9 × 12.3 mm² (264 × 264 pixels). For each analyzed region, 69696 spectra were simultaneously recorded. The principal elements detected are P, Ca, and Sr, coming from the ivory material itself; Cu, characteristic of pigments; Fe and Pb, representing sediments or pigments; Mn, revealing deposited soil minerals; Ti, indicating restoration processes or correlated with Fe sediment traces; and Au, linked to a former gilding. This provides essential information for the assessment of the original appearance of the ivory carvings. The determined elemental maps specific of possible pigments are superimposed on one another to visualize their respective distributions and reconstruct the original polychromy and gilding. Reliable hypotheses for the reconstruction of the original polychromy of the carved ivories are postulated on this basis. KW - SR-FF-microXRF KW - Elemental imaging KW - Ivory KW - Paints KW - Au NPs KW - Egyptian blue KW - Fe PY - 2013 DO - https://doi.org/10.1021/ac4006167 SN - 0003-2700 SN - 1520-6882 VL - 85 IS - 12 SP - 5857 EP - 5866 PB - American Chemical Society CY - Washington, DC AN - OPUS4-30222 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Rauwolf, M. A1 - Turyanskaya, A. A1 - Roschger, A. A1 - Prost, J. A1 - Simon, R. A1 - Scharf, O. A1 - Radtke, Martin A1 - Schoonjans, Tom A1 - de Oliveira Guilherme Buzanich, Ana A1 - Klaushofer, K. A1 - Wobrauschek, P. A1 - Hofstaetter, J. G. A1 - Roschger, P. A1 - Streli, C. T1 - Synchrotron radiation micro X-ray fluorescence spectroscopy of thin structures in bone samples: comparison of confocal and color X-ray camera setups N2 - In the quest for finding the ideal synchrotron-radiation-induced imaging method for the investigation of trace element distributions in human bone samples, experiments were performed using both a scanning confocal synchrotron radiation micro X-ray fluorescence (SR-mXRF) (FLUO beamline at ANKA) setup and a full-field color X-ray camera (BAMline at BESSY-II) setup. As zinc is a trace element of special interest in bone, the setups were optimized for its detection. The setups were compared with respect to count rate, required measurement time and spatial resolution. It was demonstrated that the ideal method depends on the element of interest. Although for Ca (a major constituent of the bone with a low energy of 3.69 keV for its K alpha XRF line) the color X-ray camera provided a higher resolution in the plane, for Zn (a trace element in bone) only the confocal SR-µXRF setup was able to sufficiently image the distribution. KW - Synchrotron KW - BAMline KW - BESSY KW - XRF KW - X-ray Color Camera PY - 2017 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-391944 DO - https://doi.org/10.1107/S1600577516017057 SN - 1600-5775 VL - 24 SP - 307 EP - 311 PB - International Union of Crystallography AN - OPUS4-39194 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Reiche, I. A1 - Berger, Achim A1 - Duval, A. A1 - Guicharnaud, H. A1 - Merchel, Silke A1 - Radtke, Martin A1 - Schäfer, D. A1 - Simon, R. T1 - SY-XRF study of Hans Baldung Grien silverpoint drawings and the silver stylus from the 'Karlsruhe sketchbook' N2 - We performed spatially resolved synchrotron-induced x-ray fluorescence analyses (SY-XRF) of five silverpoint drawings from the famous `Karlsruhe sketchbook´ and a silverpoint, which is assumed to be an original one used by the Renaissance artist Hans Baldung Grien (1484-1545) himself. The silverpoint, one out of a very small number of ancient styli conserved nowadays, is fixed on the so-called `Karlsruhe sketchbook´. Measurements were executed at the FLUO-TOPO beamline at the electron storage ring ANKA. It has been shown, that SY-XRF at this beamline is nondestructive and sensitive enough for the analysis of minor and major elements in the silver strokes. This study provides new insights into this graphical technique and ancient drawing instruments: results are that three drawings have been created with a common type of silverpoint containing about (10.4 ± 0.7) wt% of Cu. In all the cases, Hg at a 10% level by weight was identified in the strokes. Presence of Hg is not due to the original silver alloy, but is a result of a general alteration phenomenon of silverpoint drawings. This fact is confirmed by the analysis of the original silverpoint, which contains only small traces of Hg. The result for the copper content of the silverpoint (10.4 ± 1.7) wt% is in good agreement with that of these three drawings. It is supposable that the silverpoint found attached today served for the creation of the corresponding drawings. Moreover, the graphical technique of Baldung is found to be continual over three decades. Only one very late drawing dated to 1543 was probably realized with another silverpoint, containing about 3 wt% of Cu. This difference in the chemical composition of drawings from the late period might be used as a more precise dating indicator of Baldung drawings that are not clearly attributed to a certain period. KW - Synchrotron KW - XRF analysis KW - Drawings KW - Silver stylus PY - 2007 DO - https://doi.org/10.1002/xrs.963 SN - 0049-8246 VL - 36 IS - 3 SP - 173 EP - 177 PB - Wiley CY - Chichester AN - OPUS4-16150 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Vasilescu, A. A1 - Constantinescu, B. A1 - Bugoi, R. A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Simon, R. ED - Denecke, M. ED - Walker, C. T1 - Gold provenance studies for Romanian archaeological objects using micro-SR-XRF N2 - Studies by Synchrotron Radiation-X-Ray Fluorescence (SR-XRF) for the search of the presence of trace elements like Sb, Sn, Te and Pb in archaeological metallic objects found on the territory of Romania-old coins and Bronze Age jewelry, aimed to determine the provenance of the gold used in their manufacture. The results are compared with the detailed elemental composition of alluvial or primary gold samples, obtained by the same technique. This work attempted to establish the origin of the gold used for the mint of two different types of koson coins. We found that the kosons with monogram are made of refined gold, while the one used for the kosons without monogram is mainly alluvial. The gold used in the manufacture of the Calarasi Vulchitrun-type disk and the Tauteu hair ring is also of alluvial origin. T2 - 20th International congress on X-ray optics and microanalysis CY - Karlsruhe, Germany DA - 2009-09-14 KW - Provenance KW - Gold KW - SR-XRF KW - Trace elements PY - 2010 UR - http://link.aip.org/link/?APCPCS/1221/139/1 SN - 978-0-7354-0764-0 DO - https://doi.org/10.1063/1.3399240 SN - 0094-243X SP - 139 EP - 143 PB - American Institute of Physics AN - OPUS4-21182 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Berger, Achim A1 - Calligaro, T. A1 - Duval, A. A1 - Görner, Wolf A1 - Guerra, M.-F. A1 - Merchel, Silke A1 - Radtke, Martin A1 - Reiche, I. A1 - Riesemeier, Heinrich A1 - Roth, M. T1 - Study of Ag and Au based historical and archaeological objects by high energy Sy-XRF KW - Synchrotron KW - XRF analysis KW - Drawings KW - Archaeometry KW - Gold KW - Röntgenfluoreszenzanalyse KW - RFA KW - Zeichnungen KW - Archäometrie KW - Albrecht Dürer KW - gold PY - 2004 UR - http://www.helmholtz-berlin.de/media/media/oea/web/pr_webseite/druckschriften/berichte/bessy/annualreport2003.pdf#page=544 SN - 0179-4159 SP - 544 EP - 546 PB - Berliner Elektronenspeicherring-Gesellschaft für Synchrotronstrahlung CY - Berlin AN - OPUS4-3507 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Nowak, S.H. A1 - Bjeoumikhov, A. A1 - Von Borany, J. A1 - Buchriegler, J. A1 - Munnik, F. A1 - Petric, M. A1 - Radtke, Martin A1 - Renno, A.D. A1 - Reinholz, Uwe A1 - Scharf, O. A1 - Wedell, R. T1 - Sub-pixel resolution with a color X-ray camera N2 - The color X-ray camera SLcam® is a full-field, single photon detector providing scanning-free, energy and spatially resolved X-ray imaging. Spatial resolution is achieved with the use of polycapillary optics guiding X-ray photons from small regions on a sample to distinct energy dispersive pixels on a charged-coupled device detector. Applying sub-pixel resolution, signals from individual capillary channels can be distinguished. Therefore, the SLcam® spatial resolution, which is normally limited to the pixel size of the charge-coupled device, can be improved to the size of individual polycapillary channels. In this work a new approach to a sub-pixel resolution algorithm comprising photon events also from the pixel centers is proposed. The details of the employed numerical method and several sub-pixel resolution examples are presented and discussed. KW - Color X-ray camera KW - Sub pixel analysis PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-334948 DO - https://doi.org/10.1039/c5ja00028a SN - 0267-9477 SN - 1364-5544 SP - 1890 EP - 1897 PB - Royal Society of Chemistry CY - London AN - OPUS4-33494 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Reiche, I. A1 - Berger, Achim A1 - Duval, A. A1 - Görner, Wolf A1 - Guicharnaud, H. A1 - Merchel, Silke A1 - Radtke, Martin A1 - Riederer, J. A1 - Riesemeier, Heinrich A1 - Roth, M. ED - Röhrs, S. T1 - Auf den Spuren Albrecht Dürers - Zerstörungsfreie Untersuchung von Silberstiftzeichnungen mittels Mikro-PIXE und Synchrotron-induzierter Mikro-RFA T2 - Jahrestagung 2003 im Ethnologischen Museum Berlin-Dahlem CY - Berlin, Deutschland DA - 2003-03-12 PY - 2003 SN - 3-00-014223-1 SN - 0949-4057 SP - 118 EP - 120 CY - [Frankfurt am Main] AN - OPUS4-2356 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Reiche, I. A1 - Berger, Achim A1 - Duval, A. A1 - Görner, Wolf A1 - Guicharnaud, H. A1 - Merchel, Silke A1 - Radtke, Martin A1 - Riederer, J. A1 - Riesemeier, Heinrich A1 - Roth, M. ED - Marabelli, M. ED - Tabaso, M. T1 - Spatially resolved SR-XRF analyses of complex drawings of the Holbein family T2 - 8th International Conference on "Non-Destructive Investigations and Microanalysis for the Diagnostics and Conservation of the Cultural and Environmental Heritage" CY - Lecce, Italy DA - 2005-05-15 KW - X-ray spectrometry KW - XRF KW - Röntgenfluoreszenzanalyse KW - RFA KW - Silverpoint drawing KW - Silberstiftzeichnung PY - 2005 SP - 7 pages PB - Italian Society of Non Destructive Testing CY - Lecce AN - OPUS4-7677 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Merchel, Silke A1 - Berger, Achim A1 - Görner, Wolf A1 - Radtke, Martin A1 - Riesemeier, Heinrich A1 - Reiche, I. A1 - Riederer, J. A1 - Duval, A. A1 - Guicharnaud, H. T1 - Non-Destructive Investigations of Dürer's Silver Point Drawings by Pixe and SY-XRF T2 - 7th International Conference on Non-destructive testing and Microanalysis for the Diagnostics and Conservation of the Cultural and Environmental Heritage ; art 2002 CY - Antwerp, Belgium DA - 2002-06-02 PY - 2002 UR - http://srs.dl.ac.uk/arch/publications/reiche/reiche_fullcorr.pdf SP - 82 AN - OPUS4-1400 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Reiche, I. A1 - Berger, Achim A1 - Duval, A. A1 - Görner, Wolf A1 - Guicharnaud, H. A1 - Merchel, Silke A1 - Radtke, Martin A1 - Riederer, J. A1 - Riesemeier, Heinrich A1 - Roth, M. ED - Denker, A. ED - Adriaens, A. ED - Dowsett, M. ED - Giumlia-Mair, A. T1 - Synchrotron radiation and protons on the traces of famous artists - Non-destructive analyses of silverpoint drawings by Albrecht Dürer KW - X-ray spectrometry KW - XRF KW - Röntgenfluoreszenzanalyse KW - RFA KW - Silverpoint drawing KW - Silberstiftzeichnung PY - 2006 SN - 3-8167-7178-5 SP - 91 EP - 101 PB - Fraunhofer-IRB-Verl. CY - Stuttgart AN - OPUS4-14190 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Reiche, I. A1 - Berger, Achim A1 - Duval, A. A1 - Görner, Wolf A1 - Guicharnaud, H. A1 - Merchel, Silke A1 - Radtke, Martin A1 - Riederer, J. A1 - Riesemeier, Heinrich T1 - Traces of Albrecht Dürer: Non-destructive analyses of Renaissance silverpoint drawings KW - Nuclear industry KW - Nuclear medicine PY - 2004 SN - 92-0-114703-1 SN - 0074-1876 IS - 1181 SP - 138 EP - 142 PB - IAEA CY - Vienna AN - OPUS4-5548 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Reiche, I. A1 - Radtke, Martin A1 - Berger, Achim A1 - Görner, Wolf A1 - Ketelsen, T. A1 - Merchel, Silke A1 - Riederer, J. A1 - Riesemeier, Heinrich A1 - Roth, M. T1 - Spatially resolved synchrotron-induced X-ray fluorescence analyses of metal point drawings and their mysterious inscriptions N2 - Synchrotron-induced X-ray fluorescence (Sy-XRF) analysis was used to study the chemical composition of precious Renaissance silverpoint drawings. Drawings by famous artists such as Albrecht Dürer (1471–1528) and Jan van Eyck (approximately 1395–1441) must be investigated non-destructively. Moreover, extremely sensitive synchrotron- or accelerator-based techniques are needed since only small quantities of silver are deposited on the paper. New criteria for attributing these works to a particular artist could be established based on the analysis of the chemical composition of the metal points used. We illustrate how analysis can give new art historical information by means of two case studies. Two particular drawings, one of Albrecht Dürer, showing a profile portrait of his closest friend, “Willibald Pirckheimer” (1503), and a second one attributed to Jan van Eyck, showing a “Portrait of an elderly man”, often named “Niccolò Albergati”, are the object of intense art historical controversy. Both drawings show inscriptions next to the figures. Analyses by Sy-XRF could reveal the same kind of silverpoint for the Pirckheimer portrait and its mysterious Greek inscription, contrary to the drawing by Van Eyck where at least three different metal points were applied. Two different types of silver marks were found in this portrait. Silver containing gold marks were detected in the inscriptions and over-subscriptions. This is the first evidence of the use of gold points for metal point drawings in the Middle Ages. KW - Sy-XRF analysis KW - Drawing KW - Metal point KW - Albrecht Dürer KW - Jan van Eyck KW - Renaissance PY - 2004 DO - https://doi.org/10.1016/j.sab.2004.07.023 SN - 0584-8547 SN - 0038-6987 VL - 59 IS - 10-11 SP - 1657 EP - 1662 PB - Elsevier CY - Amsterdam AN - OPUS4-4575 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Reiche, I. A1 - Berger, Achim A1 - Görner, Wolf A1 - Merchel, Silke A1 - Radtke, Martin A1 - Riederer, J. A1 - Riesemeier, Heinrich A1 - Roth, M. T1 - Following the traces of Albrecht Dürer: analysis of silverpoint drawings by spatially resolved synchrotron-induced X-ray fluorescence analysis N2 - Spatially resolved X-ray fluorescence analysis using synchrotron radiation (SR-XRF) at the wavelength shifter beamline, BAMline, at BESSY was used to investigate Renaissance silverpoint drawings as it is extremely sensitive, non-destructive and can be carried out in air using an excitation spot in the hundred micrometer range. This paper deals with first results of the study of silverpoint drawings of Albrecht Dürer (1471–1528) belonging to the sketchbook that Albrecht Dürer used during a travel to the Netherlands in 1520/21. These results are compared to a PIXE study performed on drawings from the same sketchbook. The minor element composition of the silverpoint used for the drawings in the sketchbook was (10.6 ± 3.5) wt.% of Cu and traces of Zn. Mercury was found in the marks but does not belong to the initial composition of the silverpoint as it is attributed to an alteration phenomenon. One drawing of the sketchbook represents an exception. It consists of silver marks containing an additional minor element, Zn, in the marks and was, therefore, created with another silverpoint, probably at a different time than the other drawings. KW - Synchrotron KW - SR-XRF analysis KW - Drawing KW - Silverpoint KW - Albrecht Dürer PY - 2004 DO - https://doi.org/10.1016/j.nimb.2004.03.081 SN - 0168-583X SN - 1872-9584 VL - 226 IS - 1-2 SP - 83 EP - 91 PB - Elsevier CY - Amsterdam AN - OPUS4-4574 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Reiche, I. A1 - Berger, Achim A1 - Bevers, H. A1 - Dupuis, G. A1 - Duval, A. A1 - Görner, Wolf A1 - Guicharnaud, H. A1 - Merchel, Silke A1 - Radtke, Martin A1 - Riederer, J. A1 - Riesemeier, Heinrich A1 - Roth, M. T1 - Spatially resolved SR-XRF analyses of complex drawings by the Holbein family and silverpoint drawings by Rembrandt KW - X-ray spectrometry KW - XRF KW - Röntgenfluoreszenzanalyse KW - RFA KW - Silverpoint drawing KW - Silberstiftzeichnung PY - 2005 UR - http://www.helmholtz-berlin.de/media/media/oea/web/pr_webseite/druckschriften/berichte/bessy/annualreport2004.pdf#page=491 SN - 0179-4159 SP - 491 EP - 493 PB - Berliner Elektronenspeicherring-Gesellschaft für Synchrotronstrahlung CY - Berlin AN - OPUS4-7380 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin A1 - Reiche, I. A1 - Berger, Achim A1 - Merchel, Silke A1 - Riesemeier, Heinrich A1 - Görner, Wolf A1 - Riederer, J. A1 - Roth, M. ED - Simionovici, A. T1 - BAMline meets Dürer and Van Eyck - Spatially resolved SR-XRF analyses of silver point drawings and their mysterious inscriptions T2 - 17th International Conference on X-Ray Optics and Microanalysis ; 17th ICXOM CY - Chamonix, France DA - 2003-09-22 PY - 2003 N1 - Serientitel: Spectrochimica acta : Part B, Atomic spectroscopy – Series title: Spectrochimica acta : Part B, Atomic spectroscopy IS - 59.2004,10/11 SP - 48 PB - Elsevier CY - Amsterdam AN - OPUS4-2690 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Reiche, I. A1 - Berger, Achim A1 - Duval, A. A1 - Görner, Wolf A1 - Merchel, Silke A1 - Radtke, Martin A1 - Riederer, J. A1 - Riesemeier, Heinrich T1 - Metallstiftzeichnungen Albrecht Dürers KW - Synchrotron KW - XRF analysis KW - Drawings KW - Archaeometry KW - Röntgenfluoreszenzanalyse (RFA) KW - Zeichnungen KW - Archäometrie KW - Albrecht Dürer PY - 2004 SN - 1563-2628 VL - 5 IS - 2 SP - 30 EP - 38 PB - Foto Text Verl. CY - Stuttgart AN - OPUS4-3570 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Lutz, C. A1 - Breuckmann, M. A1 - Hampel, S. A1 - Kreyenschmidt, M. A1 - Ke, X. A1 - Beuermann, S. A1 - Schafner, K. A1 - Turek, T. A1 - Kunz, U. A1 - de Oliveira Guilherme Buzanich, Ana A1 - Radtke, Martin A1 - Fittschen, U. E. A. T1 - Characterization of Dimeric Vanadium Uptake and Species in Nafion™ and Novel Membranes from Vanadium Redox Flow Batteries Electrolytes N2 - A core component of energy storage systems like vanadium redox flow batteries (VRFB) is the polymer electrolyte membrane (PEM). In this work, the frequently used perfluorosulfonic-acid (PFSA) membrane Nafion™ 117 and a novel poly (vinylidene difluoride) (PVDF)-based Membrane are investigated. A well-known problem in VRFBs is the vanadium permeation through the membrane. The consequence of this so-called vanadium crossover is a severe loss of capacity. For a better understanding of vanadium transport in membranes, the uptake of vanadium ions from electrolytes containing Vdimer(IV–V) and for comparison also V(II), V(III), V(IV), and V(V) by both membranes was studied. UV/VIS spectroscopy, X-ray absorption near edge structure spectroscopy (XANES), total reflection X-ray fluorescence spectroscopy (TXRF), inductively coupled plasma optical emission spectrometry (ICP-OES), and micro X-ray fluorescence spectroscopy (microXRF) were used to determine the vanadium concentrations and the species inside the membrane. The results strongly support that Vdimer(IV–V), a dimer formed from V(IV) and V(V), enters the nanoscopic water-body of Nafion™ 117 as such. This is interesting, because as of now, only the individual ions V(IV) and V(V) were considered to be transported through the membrane. Additionally, it was found that the Vdimer(IV–V) dimer partly dissociates to the individual ions in the novel PVDF-based membrane. The Vdimer(IV–V) dimer concentration in Nafion™ was determined and compared to those of the other species. After three days of equilibration time, the concentration of the dimer is the lowest compared to the monomeric vanadium species. The concentration of vanadium in terms of the relative uptake λ = n(V)/n(SO3 ) are as follows: V(II) [λ = 0.155] > V(III) [λ = 0.137] > V(IV) [λ = 0.124] > V(V) [λ = 0.053] > Vdimer(IV–V) [λ = 0.039]. The results show that the Vdimer(IV–V) dimer Needs to be considered in addition to the other monomeric species to properly describe the transport of vanadium through Nafion™ in VRFBs. KW - MicroXRF KW - VRFB KW - PVDF-based membrane KW - UV/VIS KW - XANES KW - TXRF KW - ICP-OES PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-530676 DO - https://doi.org/10.3390/membranes11080576 VL - 11 IS - 8 SP - 576 PB - MDPI AN - OPUS4-53067 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Guerra, M. F. A1 - Fischer, M. A1 - Radtke, Martin A1 - Reinholz, Uwe T1 - Inca figurines from the Ethnologisches Museum in Berlin: an analytical study of some typical and atypical productions N2 - Fourteen hollow and one cast anthropomorphic and zoomorphic figurines produced in Incan times for ritual offerings from the Ethnologisches Museum in Berlin were selected to investigate the technologies and alloys used for their fabrication with portable optical microscopy and non-destructive XRF elemental analysis. This group of gold and silver figurines includes typical specimens of the Inca production, such as the four silver figurines from the Island Coati in Lake Titicaca and the two gold figurines from Pachacamac, as well as specimens that are seldom present in collections, which makes them atypical. In addition to the tall figurines with atypical hair or standing pose, one bicolour figurine half silver, half gold) and another with coloured inlays were included in this study for comparison. The large majority of the silver specimens are made from very high quality alloys and the gold figurines are made from alloys containing low copper contents and silver ranging from 30wt% to 52wt%. KW - Gold KW - pXRF KW - Inca PY - 2017 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-436015 DO - https://doi.org/10.4000/bifea.8232 SN - 0303-7495 VL - 46 IS - 1 SP - 221 EP - 251 PB - Institut Français d'Études Andines AN - OPUS4-43601 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Hahn, Oliver A1 - Denker, A. A1 - Merchel, S. A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Wolff, T. ED - Armbruster, B. ED - Eilbracht, H. ED - Hahn, Oliver ED - Heinrich-Tamaska, O. T1 - Zerstörungsfreie Analyse von Metallartefakten - Eine Fallstudie N2 - Die naturwissenschaftliche Analyse historischer Materialen ermöglicht die Beantwortung kulturhistorischer Fragestellungen, die mit kunsthistorischen oder archäologischen Ansätzen allein nicht zu leisten sind. In dieser Studie wurden sechs römische Münzen mit unterschiedlich stark ausgeprägten Korrosionsschichten an unbehandelten und polierten Stellen mit vier zerstörungsfreien analytischen Methoden untersucht: Hoch- und Niederenergie Protonen Induzierter Röntgenemission (HE-/PIXE), Synchrotronstrahlungsinduzierte-Röntgenfluoreszenzanalyse (SY-RFA) und Mikro-Röntgenfluoreszenzanalyse (Mikro-RFA) mit einem mobilen Gerät. Aufgrund von Unterschieden in den Messbedingungen und dem Einfluss der Patina-Schichten auf diese ergaben sich nur für wenige Elemente Übereinstimmungen in den quantitativen Daten. Zur Validierung zukünftiger Messkampagnen mit verschiedenen Methoden sind daher Vergleichstudien unerlässlich. N2 - Investigations of physical properties and chemical composition of ancient materials generate important data for answering culture-historical questions that cannot be solved by art historical and archaeological methods alone. This contribution reports on the analysis of six Roman coins, with different degrees of corrosion layers in parts that were not handled or polished, using four non-destructive methods: low-energy particle-induced X-ray emission (PIXE, 2 MeV), high-energy PIXE (68 MeV), μ-X-ray fluorescence (XRF) spectrometry with a portable device and synchrotron-radiation induced XRF. Because of differences in the conditions needed for measurement and the influence of the layers of patina on these measurements, there were few elements where the quantitative data were in agreement. Thus comparative analyses are essential to validate future measurement projects using different methods. KW - Zerstörungsfreie Prüfung KW - Protoneninduzierte Röntgenemission KW - Röntgenfluoreszenzanalyse KW - Non-destructive testing KW - Particle-induced X-ray emission KW - X-ray fluorescence analysis PY - 2016 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-385702 SN - 978-3-9816751-5-3 VL - Berlin studies of the ancient world, Band 35 SP - 117 EP - 137 PB - Edition Topoi CY - Berlin AN - OPUS4-38570 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hahn, Michael A1 - Buzanich, Günter A1 - Jähn, Katharina A1 - Reinholz, Uwe A1 - Radtke, Martin T1 - Analysis of cobalt deposition in periprosthetic bone specimens by high-resolution synchroton XRF in undecalcified histological thin sections N2 - Increasing numbers of implant revisions are a current clinical issue. Interactions of the endoprosthesis biomaterial with the body affect implantation time by wear processes, i.e. corrosion and abrasion. Previously, cobalt-chrome implants were shown to cause high levels of cobalt ions being deposited in the bone matrix. To determine a poten- tial functional role of these ions on bone homeostasis, we have developed a non-destructive dual analysis of highly sensitive elemental analysis by synchrotron XRF directly in undecalcified histological bone thin sections (4 μm). In this study, samples from 28 bone samples from hip endoprosthesis carriers (Surface Replacement Arthroplasty, metal-on-metal bearing) with an implant lifetime of 17–1750 days were used. Results were compared to age- matched control specimens. The histological analysis identified areas of bone cell activity and assigned them for XRF measurements. Co-Cr wear particles were identified in the bone marrow. In addition, Co ions were highly enriched in the mineralized bone matrix. The cobalt deposits were not homogeneously distributed, and areas of high signal intensity were identified. Co was distinctly deposited in the newly formed osteoid layer, but also within deeper layers of the bone matrix, whereby the Co concentration increased with higher degrees of bone matrix mineralization. In the current study, we determined cobalt accumulations in the bone matrix and showed for the first time via synchrotron XRF with a high spatial resolution direct on histological slides, that cobalt deposits in the mineralized bone matrix in a mineral-specific way that is dependent upon the implant lifetime. KW - Implant material KW - Cobalt deposition KW - Bone matrix KW - High-resolution synchrotron XRF KW - Histology PY - 2019 DO - https://doi.org/10.1016/j.mtla.2019.100290 SN - 2589-1529 VL - 6 SP - 100290, 1 EP - 8 PB - Elsevier Inc. CY - Amsterdam, Niederlande AN - OPUS4-47620 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Vogel, Christian A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Schäfers, F. A1 - Adam, Christian T1 - Chemical state of chromium, sulfur, and iron in sewage sludge ash based phosphorus fertilizers N2 - As an essential element of all life forms, phosphorus (P) is vital to the fertilizer industry. With decreasing quantity and quality of phosphate rock resources, recycling P-fertilizers from wastewater is of increasing interest. The P-fertilizer products of a recently developed thermochemical process for P recovery from sewage sludge ash (SSA) were investigated by chromium, sulfur, and iron K-edge X-ray near-edge structure (XANES) spectroscopy. This paper focuses the formation and prevention of toxic chromium(VI) and toxic sulfides during the thermochemical processes. Reducing conditions prevent the oxidation of chromium(III) in the SSA to toxic chromium(VI). Sulfides formed under the reducing conditions are nontoxic iron sulfides. Hematite (Fe2O3) present in the SSA is reduced to magnetite (Fe3O4). A gentle post-treatment at 400 °C under oxidizing conditions converts the iron sulfides into plant-available iron sulfates. This oxidative post-treatment does not form undesired chromium(VI) compounds. KW - X-ray absorption near-edge structure (XANES) spectroscopy KW - Phosphorus recovery KW - Sewage sludge ash KW - Chromium KW - Sulfur KW - Iron PY - 2015 DO - https://doi.org/10.1021/acssuschemeng.5b00678 SN - 2168-0485 VL - 3 IS - 10 SP - 2376 EP - 2380 PB - ACS Publ. CY - Washington, DC AN - OPUS4-34166 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - de Oliveira Guilherme Buzanich, Ana A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich A1 - Emmerling, Franziska ED - de Oliveira Guilherme Buzanich, Ana T1 - Time- and spatial-resolved X-ray absorption fine structure (XAFS) spectroscopy in a single-shot: new analytical possibilities for in situ material characterization N2 - A new concept that comprises both time- and lateral-resolved X-ray absorption fine-structure information simultaneously in a single shot is presented. This uncomplicated set-up was tested at the BAMline at BESSY-II (Berlin, Germany). The primary broadband beam was generated by a double multilayer monochromator. The transmitted beam through the sample is diffracted by a convexly bent Si (111) crystal, producing a divergent beam. This, in turn, is collected by either an energy-sensitive area detector, the so-called color X-ray camera, or by an area-sensitive detector based on a CCD camera, in θ-2θ geometry. The first tests were performed with thin metal foils and some iron oxide mixtures. A time resolution of lower than 1 s together with a spatial resolution in one dimension of at least 50 µm is achieved. KW - Single-shot XAFS KW - Time resolution KW - Spatial resolution KW - Divergent XAFS PY - 2016 DO - https://doi.org/10.1107/S1600577516003969 SN - 1600-5775 VL - 23 SP - 769 EP - 776 PB - International Union of Crystallography AN - OPUS4-38370 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Radtke, Martin A1 - Buzanich, Günter A1 - de Oliveira Guilherme Buzanich, Ana A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich A1 - Scharf, O. A1 - Scholz, Philipp A1 - Guerra, M.F. T1 - Double Dispersive X-Ray Fluorescence (D2XRF) based on an Energy Dispersive pnCCD detector for the detection of platinum in gold N2 - With the aim of improving limits of detection (LOD) of trace elements in a matrix with adjacent fluorescence energies, a simple double dispersive X-ray fluorescence detection system (D2XRF) was constructed to operate at the beamlines BAMline and the mySpot @ BESSY II. This system is based on the combination of a crystal analyzer with an energy resolving single photon counting pnCCD. Without further collimators, the efficient suppression of the background by the pnCCD and the good energy resolution of the crystal results in improved LOD. In first order reflections, an energy resolution of 13 eV for Cu Kα was reached, and an energy range of 1 keV was covered in one shot. This new system was applied to the detection of platinum (Pt) in gold leaves with a LOD of 0.9 mg/kg, which is the lowest attained by totally non-destructive methods nowadays. The presence of Pt in gilded objects from Abydos and Byzantine mosaics provides vital information, as it indicates the alluvial origin of the gold for these examples. KW - Platinum Wavelength dispersive D2XRF KW - Gold Synchrotron XRF PY - 2016 DO - https://doi.org/10.1016/j.microc.2015.10.039 VL - 125 SP - 56 EP - 61 PB - Elsevier Science CY - Amsterdam AN - OPUS4-35777 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Rakotondrajoa, Andrianiaina A1 - Buzanich, Günter A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich A1 - Vincze, L. A1 - Raboanary, R. T1 - Improvement of PLS regression-based XRF spectroscopy quantification using multiple step procedure and Monte Carlo simulation N2 - Partial least squares (PLS) regression-based methods have been proven to be a good alternative for quantification in X-ray fluorescence spectroscopy. These methods are fast and easy to use though giving satisfactory results under certain conditions. One of these conditions is the necessity of having a great number of spectra to build the model (training set). The choice of the constituent concentration range in the training set has a big influence on the accuracy of the model. Better accuracy is obtained if the model is built in relatively narrow regions containing (or close to) the real concentration value. In the present work, Monte Carlo (MC) simulated spectra are used to form the training set. The advantage to use MC generated training spectra is the unlimited availability of perfect standards. This paper aims to improve the accuracy of the method by introducing a multiple step procedure in order to build the PLS model using narrow concentration range close to (or containing) the real concentration values in the samples to be measured. This approach consists of an initial guess of the constituents' concentrations and a preliminary PLS model before building the final model. The prediction of ten MC simulated alloy standard samples containing Ti, Mn, Fe, Co, Cu, Zn, Sr, Zr, and Mo using this method allowed to have average relative prediction errors less than 5% for elements with narrow concentration ranges. KW - SR-microXRF KW - Quantification KW - PLS KW - Monte Carlo PY - 2013 DO - https://doi.org/10.1002/xrs.2479 SN - 0049-8246 VL - 42 IS - 4 SP - 183 EP - 188 PB - Wiley CY - Chichester AN - OPUS4-30225 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin A1 - Fittschen, U.E.A. A1 - Menzel, M. A1 - Scharf, O. A1 - Horntrich, C. A1 - Streli, C. A1 - Montoya, V. A1 - McIntosh, K. A1 - Havrilla, G.J. T1 - THE IDEAL SPECIMENT FOR TOTAL REFLECTION X-RAY FLUORESCENCE (TXRF) ANALYSIS: RESULTS FROM SIMULATIONS AND EXPERIMENTAL EVALUATION T2 - International Congress on X-Ray Optics and Microanalysis CY - Hamburg, Germany DA - 2013-09-02 PY - 2013 AN - OPUS4-29871 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Menzel, Michael A1 - Fittschen, U.E.A. A1 - Scharf, Oliver T1 - ABSORBTION OF THE PRIMARY BEAM IN SR-TXRF ANALYSIS: EXPERIMENTAL VISUALIZATION USING A COLOR X-RAY CAMERA T2 - International Congress on X-Ray Optics and Microanalysis CY - Hamburg, Germany DA - 2013-09-02 PY - 2013 AN - OPUS4-29898 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin T1 - Röntgenfluoreszenzanalyse mit Synchrotronstrahlung an der Bundesanstalt für Materialforschung und -prüfung (BAM), Berlin T2 - Seminar: "Strahlenphysikalische Anwendungen in Technik und Medizin" CY - Vienna, Austria DA - 2013-01-16 PY - 2013 AN - OPUS4-29861 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin A1 - Buzanich, Günter A1 - Fittschen, U.E.A A1 - Menzel, M. A1 - Scharf, Oliver A1 - Horntrich, C. A1 - Montoya, V. A1 - McIntosh, K. A1 - Havrilla, G.J. T1 - Evaluation of total reflection X-ray fluorescence (TXRF) analysis using a color X-ray camera (CXC) T2 - 15th International Conference on Total Reflection X-Ray Fluorescence Analysis and Related Methods (TXRF2013) CY - Osaka, Japan DA - 2013-09-23 PY - 2013 AN - OPUS4-29859 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Buzanich, Günter A1 - Fittschen, U.E.A. A1 - Menzel, M. A1 - Scharf, O. A1 - Horntrich, C. A1 - Streli, C. A1 - Montoya, V. A1 - Havrilla, G.J. A1 - McIntosh, K. T1 - THE IDEAL SPECIMENT FOR TOTAL REFLECTION X-RAY FLUORESCENCE (TKRF) ANALYSIS:RESULTS FROM SIMULATIONS AMD EXPERIMENTAL EVALUATION T2 - Fifth Joint BER II and BESSY II User Meeting CY - Berlin, Germany DA - 2013-12-04 PY - 2013 AN - OPUS4-29903 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin A1 - Stalinski, T. A1 - Püschel, F. A1 - Scharf, O. A1 - Arkadiev, V. A1 - Wedell, R. T1 - Adaptive Kanalreduktion eines hyperspektralen Bilddatensatzes kombiniert mit k-mean Clustering T2 - Workshop Farbbildverarbeitung - Wuppertal 2014 CY - Wuppertal DA - 2014-09-25 PY - 2014 AN - OPUS4-32365 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin A1 - Menzel, Michael A1 - Fittschen, U.E.A. A1 - Scharf, O. T1 - ABSOPTION OF THE PRIMARY BEAM IN SR-TXRF ANALYSIS: EXPERIMENTAL VISUALIZATION USING A COLOR X-RAY CAMERA T2 - Fifth Joint BER II User Meeting CY - Berlin, Germany DA - 2013-12-04 PY - 2013 AN - OPUS4-29901 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich A1 - Guerra, M. F. A1 - Reiche, I. T1 - Between the Eurasien steppes and China: provenancing the Xiongnu gold by IBA and SRXRF T2 - Fifth Joint BER II and BESSY II User Meeting CY - Berlin, Germany DA - 2013-12-04 PY - 2013 AN - OPUS4-29905 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin A1 - Buzanich, Günter A1 - Curado, Jessica A1 - Riesemeier, Heinrich A1 - Scharf, O. T1 - Slicing - A New Method For Non Destructive 3D Elemental Sensitive Characterization Of Materials T2 - Fifth Joint BER II and BESSY II User Meeting CY - Berlin, Germany DA - 2013-12-04 PY - 2013 AN - OPUS4-29904 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin A1 - Curado, Jessica A1 - Buzanich, Günter A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich A1 - Guttler, R.A.S. A1 - Rizzutto, M.A. T1 - u-SRXRF characterization of Brazilian emeralds T2 - Fifth Joint BER II and BESSY II User Meeting CY - Berlin, Germany DA - 2013-12-04 PY - 2013 AN - OPUS4-29902 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin A1 - Buzanich, Günter A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich A1 - Scharf, O. T1 - The Color X-Ray Camera: Imaging and Beyond T2 - ANKA/KNMF User Meeting 2013 CY - 76646 Bruchsal, Deutschland DA - 2013-09-26 PY - 2013 AN - OPUS4-29900 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin T1 - Röntgenfluoreszenzanalyse mit Synchrotronstrahlung an der Bundesanstalt für Materialforschung und -prüfung (BAM), Berlin T2 - Seminar "Strahlenphysikalische Anwendungen in Technik und Medizin" CY - Wien (Österreich) DA - 2014-01-14 PY - 2014 AN - OPUS4-32367 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin A1 - Buzanich, Günter A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich A1 - Curado, Jessica T1 - Slicing - A New Method For Non Destructive 3D Elemental Sensitive Characterization Of Materials T2 - Digital Speciman 2014 CY - Berlin DA - 2014-09-08 PY - 2014 AN - OPUS4-32368 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin T1 - Experiences with the Color X-Ray Camera at the BAMline T2 - X-ray Spectroscopy Detectors for Present and Future Synchrotron Storage rings: Opportunities for Horizon 2020 CY - Paris, Frankreich DA - 2015-03-16 PY - 2015 AN - OPUS4-34009 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin A1 - Buzanich, Günter A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich A1 - Scharf, O. T1 - Double Dispersive X-ray Fluorescence T2 - EXRS 2014 CY - Bologna (Italien) DA - 2014-06-15 PY - 2014 AN - OPUS4-32370 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich T1 - Analysis of ancient gold objects with SRXRF at the BAMline T2 - Technart 2015 CY - Catania, Italien DA - 2015-04-27 PY - 2015 AN - OPUS4-34007 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -