TY - JOUR A1 - Riesemeier, Heinrich A1 - Ecker, Klaus A1 - Görner, Wolf A1 - Müller, Bernd R. A1 - Radtke, Martin A1 - Krumrey, M. T1 - Layout and first XRF Applications of the BAMline at BESSY II+ N2 - The first hard x-ray beamline at BESSY II has been installed by BAM and PTB at a superconducting 7 T wavelength shifter. The main optical elements of the beamline are a double-multilayer monochromator and a double-crystal monochromator. Depending on the application, the two devices are used separately or in-line. The main applications of the monochromatic radiation with photon energies up to 60 keV are x-ray fluorescence analysis, micro computed tomography, x-ray topography, detector calibration and reflectometry. Calculable undispersed radiation up to 200 keV is available for radiometric applications. KW - BAMline KW - XRF PY - 2005 DO - https://doi.org/10.1002/xrs.750 SN - 0049-8246 VL - 34 IS - 2 SP - 160 EP - 163 PB - Wiley CY - Chichester AN - OPUS4-11929 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Reiche, I. A1 - Radtke, Martin A1 - Berger, Achim A1 - Görner, Wolf A1 - Merchel, Silke A1 - Riesemeier, Heinrich A1 - Bevers, H. T1 - Spatially resolved synchrotron radiation induced X-ray fluorescence analyses of rare Rembrandt silverpoint drawings N2 - New analyses of a series of very rare silverpoint drawings that were executed by Rembrandt Harmensz. van Rijn (1606–1669) which are kept today in the Kupferstichkabinett (Museum of Prints and Drawings) of the State Museums of Berlin are reported here. Analysis of these drawings requires particular attention because the study has to be fully non-destructive and extremely sensitive. The metal alloy on the paper does not exceed some hundreds of µg/cm². Therefore, synchrotron radiation induced X-ray fluorescence (SR-XRF) is – together with external micro-proton-induced X-ray emission – the only well-suited method for the analyses of metalpoint drawings. In some primary work, about 25 German and Flemish metalpoint drawings were investigated using spatially resolved SR-XRF analysis at the BAMline at BESSY. This study enlarges the existing French–German database of metalpoint drawings dating from the 15th and 16th centuries, as these Rembrandt drawings originate from the 17th century where this graphical technique was even rarer and already obsolete. It also illustrates how SR-XRF analysis can reinforce art historical assumptions on the dating of drawings and their connection. KW - X-ray spectrometry KW - XRF KW - Röntgenfluoreszenzanalyse KW - RFA KW - Silverpoint drawing KW - Silberstiftzeichnung PY - 2006 DO - https://doi.org/10.1007/s00339-006-3505-4 SN - 0947-8396 VL - 83 IS - 2 SP - 169 EP - 173 PB - Springer CY - Berlin AN - OPUS4-12532 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ecker, Klaus A1 - Wätjen, U. A1 - Berger, Achim A1 - Persson, L. A1 - Pritzkow, Wolfgang A1 - Radtke, Martin A1 - Riesemeier, Heinrich T1 - RBS, SY-XRF, INAA and ICP-IDMS of antimony implanted in silicon - A multi-method approach to characterize and certify a reference material N2 - A layer of Sb atoms, implanted with an energy of 400 keV and a nominal dose of 5×1016 atoms/cm2 into a high purity silicon wafer, was certified for its areal density (atoms/cm2) using Rutherford backscattering spectrometry (RBS), instrumental neutron activation analysis (INAA) and inductively coupled plasma isotope dilution mass spectrometry (ICP-IDMS) and for its isotope ratio using INAA and ICP-IDMS. Excellent agreement between the results of the different independent methods was found. In the present work, the measurements of the homogeneity of the areal density of Sb, previously determined with RBS in spots having 1 mm diameter, are improved with synchrotron X-ray fluorescence analysis: Higher precision in even smaller sample spots allows to estimate a reduced inhomogeneity of the whole batch of samples of the order of only 0.4%. Thus the uncertainty of the certified value can further be reduced. Down to fractions of a chip with 0.3×0.4 mm2 area, the areal density is now certified as (4.81±0.06)×1016 Sb atoms/cm2, where the expanded uncertainty 0.06 (coverage factor k=2) corresponds to only 1.2%. The relative merits of the different analytical methods are discussed. KW - Certified reference material KW - RBS KW - INAA KW - ICP-IDMS KW - XRF KW - SY-XRF PY - 2002 DO - https://doi.org/10.1016/S0168-583X(01)01038-2 SN - 0168-583X SN - 1872-9584 VL - 188 IS - 1-4 SP - 120 EP - 125 PB - Elsevier CY - Amsterdam AN - OPUS4-13870 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Mans, C. A1 - Simons, C. A1 - Hanning, S. A1 - Janßen, A. A1 - Alber, D. A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Bühler, A. A1 - Kreyenschmidt, M. T1 - New polymeric candidate reference materials for XRF and LA-ICP-MS - development and preliminary characterization N2 - A set of ten calibration materials based on acrylonitrile-butadiene-styrene terpolymer (ABS) containing the elements Br, Pb, Cd, Cr, and Hg was produced in order to control polymer samples in regard to the restriction on the use of certain hazardous substances (RoHS) directive. The materials were produced with respect to the special demands of X-ray fluorescence analysis (XRF) and inductively coupled plasma mass spectrometry in combination with laser ablation (LA-ICP-MS). The mass fractions of all elements were 0-1500 mg/kg and the materials were produced as granulates and solid discs with a diameter of 40 mm and thicknesses of 1, 2, and 6 mm. It could be shown that the signals measured by XRF strongly depend on the thickness of polymeric samples. Macroscopic homogeneity was assessed with XRF measuring a total of 180 samples. The microscopic homogeneities were determined for a material with average elemental mass fractions with the aid of synchrotron radiation (SR) µ-XRF and LA-ICP-MS. Sufficient macroscopic and microscopic homogeneities for all elements could be achieved. It was observed that organic additives show a better homogeneity than oxides. XRF and LA-ICP-MS were successfully calibrated with the new materials. Limits of detection were in the range of 0.4-22 mg/kg for XRF and 2.3-26.8 mg/kg for LA-ICP-MS. The materials are considered as candidate reference materials (RM) by the Federal Institute of Materials Research and Testing (BAM, Germany). KW - XRF KW - LA.ICP-MS Plastics KW - RoHS KW - CRM PY - 2009 DO - https://doi.org/10.1002/xrs.1120 SN - 0049-8246 VL - 38 IS - 1 SP - 52 EP - 57 PB - Wiley CY - Chichester AN - OPUS4-18681 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Reifschneider, O. A1 - Vennemann, A. A1 - Buzanich, Günter A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich A1 - Hogeback, J A1 - Köppen, C. A1 - Großgarten, M. A1 - Sperling, M. A1 - Wiemann, M. A1 - Karst, U. T1 - Revealing Silver Nanoparticle Uptake by Macrophages Using SR-μXRF and LA-ICP-MS N2 - To better study the impact of nanoparticles on both in vitro and in vivo models, tissue distribution and cellular doses need to be described more closely. Here silver nanoparticles were visualized in alveolar macrophages by means of synchrotron radiation micro X-ray fluorescence spectroscopy (SR-μXRF) with high spatial resolution of 3 × 3 μm2. For the spatial allocation of silver signals to cells and tissue structures, additional elemental labeling was carried out by staining with eosin, which binds to protein and can be detected as bromine signal with SR-μXRF. The method was compatible with immunostaining of macrophage antigens. We found that the silver distribution obtained with SR-μXRF was largely congruent with distribution maps from a subsequent laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) of the same tissue sites. The study shows a predominant, though not exclusive uptake of silver into alveolar macrophages in the rat lung, which can be modeled by a similar uptake in cultured alveolar macrophages. Advantages and limitations of the different strategies for measuring nanoparticle uptake at the single cell level are discussed. KW - Synchrotron KW - BAMline KW - XRF KW - Nanoparticle KW - Macrophagen PY - 2020 DO - https://doi.org/10.1021/acs.chemrestox.9b00507 VL - 33 IS - 5 SP - 1250 EP - 1255 PB - American Chemical Society AN - OPUS4-50855 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Förste, F. A1 - Bauer, L. A1 - Streeck, C. A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Kadow, D. A1 - Keil, C. A1 - Mantouvalou, I. T1 - Quantitative Analysis and 2D/3D Elemental Imaging of Cocoa Beans Using X‑ray Fluorescence Techniques N2 - As an important raw material for the confectionery industry, the cocoa bean (Theobroma cacao L.) has to meet certain legal requirements in terms of food safety and maximum contaminant levels in order to enter the cocoa market. Understanding the enrichment and distribution of essential minerals but also toxic metals is of utmost importance for improving the nutritional quality of this economically important raw food material. We present three X-ray fluorescence (XRF) techniques for elemental bio-imaging of intact cocoa beans and one additional XRF technique for quantitative analysis of cocoa pellets. The interrelation of all the methods presented gives a detailed picture of the content and 3D-resolved distribution of elements in complete cocoa beans for the first time. KW - BAMline KW - Synchrotron KW - XRF KW - CXC KW - Cocoa PY - 2023 DO - https://doi.org/10.1021/acs.analchem.2c05370 VL - 95 SP - 5627 EP - 5635 PB - ACS Publications AN - OPUS4-57832 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Strub, Erik A1 - Plarre, Rüdiger A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich A1 - Schoknecht, Ute A1 - Urban, Klaus A1 - Jüngel, P. T1 - Determination of Cr(VI) in wood specimen: A XANES study at the Cr K edge N2 - The content of chromium in different oxidation states in chromium-treated wood was studied with XANES (X-ray absorption near-edge structure) measurements at the Cr K absorption edge. It could be shown that wood samples treated with Cr(VI) (pine and beech) did still contain a measurable content of Cr(VI) after four weeks conditioning. If such wood samples were heat exposed for 2 h with 135 °C prior conditioning, Cr(VI) was no longer detected by XANES, indicating a complete reduction to chromium (III). KW - X-ray spectroscopy KW - XANES KW - XAS KW - XRF KW - Specifikation KW - Reduction PY - 2008 DO - https://doi.org/10.1016/j.nimb.2008.03.011 SN - 0168-583X SN - 1872-9584 VL - 266 IS - 10 SP - 2405 EP - 2407 PB - Elsevier CY - Amsterdam AN - OPUS4-17555 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Strub, Erik A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich A1 - Reznikova, E. T1 - Measurements with compound refractive lenses at the "BAMline" N2 - A set of compound refractive lenses (CRLs), mounted on a silicon wafer, was obtained from the Institut für Mikrostrukturtechnik Karlsruhe. The CRLs were characterized at the BAMline at the synchrotron BESSYII in Berlin. It could be demonstrated that beam diameters below 1 µm can be obtained. The beam size accepted by the lenses is (140 × 140) µm2, thus the intensity gain in the micrometer spot, including absorption, is about 15,000. It is possible to switch between different beam energies within a few minutes. First results of scans and the application of the lenses for MicroXANES (X-ray absorption near-edge structure) measurements are presented in this paper. Also, the possibility of MicroEXAFS (extended X-ray absorption fine structure) measurements is discussed. KW - X-ray optics KW - XANES KW - EXAFS KW - XAS KW - XRF KW - Speciation PY - 2008 DO - https://doi.org/10.1016/j.nimb.2008.02.057 SN - 0168-583X SN - 1872-9584 VL - 266 IS - 10 SP - 2165 EP - 2168 PB - Elsevier CY - Amsterdam AN - OPUS4-17554 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Rauwolf, M. A1 - Turyanskaya, A. A1 - Roschger, A. A1 - Prost, J. A1 - Simon, R. A1 - Scharf, O. A1 - Radtke, Martin A1 - Schoonjans, Tom A1 - de Oliveira Guilherme Buzanich, Ana A1 - Klaushofer, K. A1 - Wobrauschek, P. A1 - Hofstaetter, J. G. A1 - Roschger, P. A1 - Streli, C. T1 - Synchrotron radiation micro X-ray fluorescence spectroscopy of thin structures in bone samples: comparison of confocal and color X-ray camera setups N2 - In the quest for finding the ideal synchrotron-radiation-induced imaging method for the investigation of trace element distributions in human bone samples, experiments were performed using both a scanning confocal synchrotron radiation micro X-ray fluorescence (SR-mXRF) (FLUO beamline at ANKA) setup and a full-field color X-ray camera (BAMline at BESSY-II) setup. As zinc is a trace element of special interest in bone, the setups were optimized for its detection. The setups were compared with respect to count rate, required measurement time and spatial resolution. It was demonstrated that the ideal method depends on the element of interest. Although for Ca (a major constituent of the bone with a low energy of 3.69 keV for its K alpha XRF line) the color X-ray camera provided a higher resolution in the plane, for Zn (a trace element in bone) only the confocal SR-µXRF setup was able to sufficiently image the distribution. KW - Synchrotron KW - BAMline KW - BESSY KW - XRF KW - X-ray Color Camera PY - 2017 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-391944 DO - https://doi.org/10.1107/S1600577516017057 SN - 1600-5775 VL - 24 SP - 307 EP - 311 PB - International Union of Crystallography AN - OPUS4-39194 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Simons, C. A1 - Mans, C. A1 - Hanning, S. A1 - Janßen, A. A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Ostermann, Markus A1 - Michaelis, Matthias A1 - Wienold, Julia A1 - Alber, D. A1 - Kreyenschmidt, M. T1 - Study on microscopic homogeneity of polymeric candidate reference materials BAM H001-BAM H010 by means of synchrotron µ-XRF and LA-ICP-MS N2 - In this study the microscopic homogeneity of the newly developed plastic reference materials BAM H001-BAM H010 was investigated. The materials consist of an acrylonitryle-butadien-styrene terpolymer, doped with different amounts of the elements Br, Cd, Cr, Hg and Pb. For the quantitative determination of the degree of homogeneity, a procedure proposed by Kempenaers et al. (Fresenius J. Anal. Chem., 2001, 369, 733-737) was used. On every sample an extensive number of different points were analyzed and standard deviation for every element mentioned above was used to calculate a minimal sampling mass that is necessary to reach a certain level of uncertainty caused by inhomogeneity (mmin,5%). The experiments were taken out with synchrotron µ-XRF (SR µ-XRF) at BESSYII in Berlin and by laser ablation inductively coupled plasma mass spectroscopy (LA-ICP-MS). The calculated values for mmin,5% of both techniques showed comparable results for all elements. It could be shown that the materials are suitable for calibration of micro analytic techniques if at least 64 µg are used. KW - XRF KW - LA-ICP-MS KW - RoHS KW - CRM PY - 2010 DO - https://doi.org/10.1039/b917008a SN - 0267-9477 SN - 1364-5544 VL - 25 SP - 40 EP - 43 PB - Royal Society of Chemistry CY - London AN - OPUS4-20938 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -