TY - JOUR A1 - de Oliveira Guilherme Buzanich, Ana A1 - Kulow, Anicó A1 - Kabelitz, Anke A1 - Grunewald, C. A1 - Seidel, R. A1 - Chapartegui-Arias, Ander A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Emmerling, Franziska A1 - Beyer, S. T1 - Observation of early ZIF-8 crystallization stages with X-ray absorption spectroscopy N2 - The present study investigates early stages of ZIF-8 crystallization up to 5 minutes post mixing of precursor solutions. Dispersive X-ray Absorption Spectroscopy (DXAS) provides a refined understanding of the evolution of the coordination environment during ZIF-8 crystallization. Linear Combination Fiting (LCF) suggests tetrakis(1-methylimidazole)zinc2+ to be a suitable and stable mononuclear structure analogue for some early stage ZIF-8 intermediates. Our results pave the way for more detailed studies on physico-chemical aspects of ZIF-8 crystallization to better control tailoring ZIF-8 materials for specific applications. KW - In-situ KW - XANES KW - ZIF-8 KW - Crystallization PY - 2020 DO - https://doi.org/10.1039/D0SM01356K SN - 1744-6848 VL - 17 IS - 2 SP - 331 EP - 334 PB - Royal Scociety of Chemistry AN - OPUS4-51723 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin A1 - Fittschen, U. E. A. T1 - Shading Effects in SR-TXRF: Calculations and Experimental Visualization using a Color X-ray Camera T2 - Denver X-ray Conference CY - BIG SKY RESORT, BIG SKY, MONTANA, USA DA - 2014-07-28 PY - 2014 AN - OPUS4-32371 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Lutz, C. A1 - Breuckmann, M. A1 - Hampel, S. A1 - Kreyenschmidt, M. A1 - Ke, X. A1 - Beuermann, S. A1 - Schafner, K. A1 - Turek, T. A1 - Kunz, U. A1 - de Oliveira Guilherme Buzanich, Ana A1 - Radtke, Martin A1 - Fittschen, U. E. A. T1 - Characterization of Dimeric Vanadium Uptake and Species in Nafion™ and Novel Membranes from Vanadium Redox Flow Batteries Electrolytes N2 - A core component of energy storage systems like vanadium redox flow batteries (VRFB) is the polymer electrolyte membrane (PEM). In this work, the frequently used perfluorosulfonic-acid (PFSA) membrane Nafion™ 117 and a novel poly (vinylidene difluoride) (PVDF)-based Membrane are investigated. A well-known problem in VRFBs is the vanadium permeation through the membrane. The consequence of this so-called vanadium crossover is a severe loss of capacity. For a better understanding of vanadium transport in membranes, the uptake of vanadium ions from electrolytes containing Vdimer(IV–V) and for comparison also V(II), V(III), V(IV), and V(V) by both membranes was studied. UV/VIS spectroscopy, X-ray absorption near edge structure spectroscopy (XANES), total reflection X-ray fluorescence spectroscopy (TXRF), inductively coupled plasma optical emission spectrometry (ICP-OES), and micro X-ray fluorescence spectroscopy (microXRF) were used to determine the vanadium concentrations and the species inside the membrane. The results strongly support that Vdimer(IV–V), a dimer formed from V(IV) and V(V), enters the nanoscopic water-body of Nafion™ 117 as such. This is interesting, because as of now, only the individual ions V(IV) and V(V) were considered to be transported through the membrane. Additionally, it was found that the Vdimer(IV–V) dimer partly dissociates to the individual ions in the novel PVDF-based membrane. The Vdimer(IV–V) dimer concentration in Nafion™ was determined and compared to those of the other species. After three days of equilibration time, the concentration of the dimer is the lowest compared to the monomeric vanadium species. The concentration of vanadium in terms of the relative uptake λ = n(V)/n(SO3 ) are as follows: V(II) [λ = 0.155] > V(III) [λ = 0.137] > V(IV) [λ = 0.124] > V(V) [λ = 0.053] > Vdimer(IV–V) [λ = 0.039]. The results show that the Vdimer(IV–V) dimer Needs to be considered in addition to the other monomeric species to properly describe the transport of vanadium through Nafion™ in VRFBs. KW - MicroXRF KW - VRFB KW - PVDF-based membrane KW - UV/VIS KW - XANES KW - TXRF KW - ICP-OES PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-530676 DO - https://doi.org/10.3390/membranes11080576 VL - 11 IS - 8 SP - 576 PB - MDPI AN - OPUS4-53067 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CHAP A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Guerra, M.F. A1 - Martinón-Torres, M. A1 - Lemasson, Q. A1 - Moignard, B. A1 - Pacheco, C. A1 - Pichon, L. A1 - Macdonald, L. A1 - Hess, M. A1 - Tissot, I. ED - Guerra, M. F. ED - Martinón-Torres, M. ED - Quirke, S. T1 - Analytical approaches to Egyptian goldwork N2 - The structure and composition of ancient gold objects retain information about their long history of manufacture, from the exploitation of the ore to the finishing touches, as well as evidence of their use, deposition, and degradation. By developing an efficient analytical strategy, it is possible to retrieve that information. This chapter sets the necessary foundation 131to explore fully the analytical results presented in the following chapters of this volume. The techniques employed in the analyses of the Egyptian jewellery are described and the analytical parameters provided. For more established techniques, only brief introductions are presented, while more recent developments are presented in greater detail. KW - Gold KW - Synchrotron KW - D2XRF KW - Egypt PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-586039 DO - https://doi.org/10.17863/CAM.99681 SP - 131 EP - 191 AN - OPUS4-58603 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - C. Pardo Pérez, L. A1 - Arndt, A. A1 - Stojkovikj, S. A1 - Y. Ahmet, I. A1 - T. Arens,, J. A1 - Dattila, F. A1 - Wendt, R. A1 - de Oliveira Guilherme Buzanich, Ana A1 - Radtke, Martin A1 - Davies, V. A1 - Höflich, K. A1 - Köhnen, E. A1 - Tockhorn, P. A1 - Golnak, R. A1 - Xiao, J. A1 - Schuck, G. A1 - Wollgarten, M. A1 - López, N. A1 - T. Mayer, M. T1 - Determining Structure-Activity Relationships in Oxide Derived CuSn Catalysts During CO2 Electroreduction Using X-Ray Spectroscopy N2 - The development of earth-abundant catalysts for selective electrochemical CO2 conversion is a central challenge. Cu-Sn bimetallic catalysts can yield selective CO2 reduction toward either CO or formate. This study presents oxide-derived Cu-Sn catalysts tunable for either product and seeks to understand the synergetic effects between Cu and Sn causing these selectivity trends. The materials undergo significant transformations under CO2 reduction conditions, and their dynamic bulk and surface structures are revealed by correlating observations from multiple methods—X-ray absorption spectroscopy for in situ study, and quasi in situ X-ray photoelectron spectroscopy for surface sensitivity. For both types of catalysts, Cu transforms to metallic Cu0 under reaction conditions. However, the Sn speciation and content differ significantly between the catalyst types: the CO-selective catalysts exhibit a surface Sn content of 13 at. % predominantly present as oxidized Sn, while the formate-selective catalysts display an Sn content of ≈70 at. % consisting of both metallic Sn0 and Sn oxide species. Density functional theory simulations suggest that Snδ+ sites weaken CO adsorption, thereby enhancing CO selectivity, while Sn0 sites hinder H adsorption and promote formate production. This study reveals the complex dependence of catalyst structure, composition, and speciation with electrochemical bias in bimetallic Cu catalysts. KW - Electrochemical CO2 conversion KW - Cu catalysts KW - X-ray absorption spectroscopy PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-547116 DO - https://doi.org/10.1002/aenm.202103328 SN - 1614-6832 VL - 12 IS - 5 SP - 2103328 PB - Wiley-VCH GmbH AN - OPUS4-54711 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Radtke, Martin A1 - Rakotondrajoa, A. T1 - Machine learning based quantification of synchrotron radiation-induced X-ray fluorescence measurements - a case study N2 - In this work, we describe the use of artificial neural networks for the quantification of X-ray fluorescence measurements. The training data were generated using Monte Carlo simulation, which avoided the use of adapted reference materials. The extension of the available data set by means of an ANN to generate additional data was demonstrated. Particular emphasis was put on the comparability of simulated and experimental data and how the influence of deviations can be reduced. The search for the optimal hyperparameter, manual and automatic, is also described. For the presented case, we were able to train a network with a mean absolute error of 0.1 weight percent for the synthetic data and 0.7 weight percent for a set of experimental data obtained with certified reference materials. KW - Machine learning KW - BAMline KW - XRF KW - Synchrotron KW - Neural network PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-519008 DO - https://doi.org/10.1088/2632-2153/abc9fb SP - 1 EP - 16 PB - IOP Publishing AN - OPUS4-51900 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Fortes Martin, R. A1 - Thünemann, Andreas A1 - Stockmann, Jörg Manfred A1 - Radnik, Jörg A1 - Koetz, J. T1 - From Nanoparticle Heteroclusters to Filament Networks by Self-Assembly at the Water–Oil Interface of Reverse Microemulsions N2 - Surface self-assembly of spherical nanoparticles of sizes below 10 nm into hierarchical heterostructures is under arising development despite the inherent difficulties of obtaining complex ordering patterns on a larger scale. Due to template-mediated interactions between oil-dispersible superparamagnetic nanoparticles (MNPs) and polyethylenimine-stabilized gold nanoparticles (Au(PEI)NPs) at the water–oil interface of microemulsions, complex nanostructured films can be formed. Characterization of the reverse microemulsion phase by UV–vis absorption revealed the formation of heteroclusters from Winsor type II phases (WPII) using Aerosol-OT (AOT) as the surfactant. SAXS measurements verify the mechanism of initial nanoparticle clustering in defined dimensions. XPS suggested an influence of AOT at the MNP surface. Further, cryo-SEM and TEM visualization demonstrated the elongation of the reverse microemulsions into cylindrical, wormlike structures, which subsequently build up larger nanoparticle superstructure arrangements. Such WPII phases are thus proven to be a new form of soft template, mediating the self-assembly of different nanoparticles in hierarchical network-like filaments over a substrate during solvent evaporation. KW - Small-angle X-ray scattering KW - SAXS KW - Nanoparticle KW - Nano structure PY - 2021 DO - https://doi.org/10.1021/acs.langmuir.1c01348 VL - 37 IS - 29 SP - 8876 EP - 8885 PB - American Chemical Society AN - OPUS4-53034 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ha, Q. L. M. A1 - Armbruster, U. A1 - Atia, Hanan A1 - Lund, H. A1 - Agostini, G. A1 - Radnik, Jörg A1 - Vuong, H. T. A1 - Martin, A. T1 - Development of active and stable low nickel content catalysts for dry reforming of methane N2 - Methane dry reforming (DRM) was investigated over highly active Ni catalysts with low metal content (2.5wt%) supported on Mg-Al mixed oxide. The aim was to minimize carbon Deposition and metal sites agglomeration on the working catalyst which are known to cause catalyst deactivation. The solids were characterized using N2 adsorption, X-ray diffraction, temperature-programmed reduction, X-ray photoelectron spectroscopy, and UV-Vis diffuse reflectance spectroscopy. The results showed that MgO-Al2O3 solid solution phases are obtained when calcining Mg-Al hydrotalcite precursor in the temperature range of 550–800 °C. Such phases contribute to the high activity of catalysts with low Ni content even at low temperature (500 °C). Modifying the catalyst preparation with citric acid significantly slows the coking rate and reduces the size of large octahedrally coordinated NiO-like domains, which may easily agglomerate on the surface during DRM. The most effective Ni catalyst shows a stable DRM course over 60 h at high weight hourly space velocity with very low coke deposition. This is a promising result for considering such catalyst systems for further development of an industrial DRM technology. KW - Dry reforming of methane KW - Carbon dioxide KW - Ni PY - 2017 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-402904 DO - https://doi.org/10.3390/catal7050157 SN - 2073-4344 VL - 7 IS - 5 SP - 157, 1 EP - 157, 17 PB - MDPI AN - OPUS4-40290 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Seeburg, Dominik A1 - Liu, Dongjing A1 - Radnik, Jörg A1 - Atia, Hanan A1 - Pohl, Marga-Martina A1 - Schneider, Matthias A1 - Martin, Andreas A1 - Wohlrab, Sebastian T1 - Structural changes of highly active Pd/MeOx (Me = Fe, Co, Ni) during catalytic methane combustion N2 - Fe2O3, Co3O4 and NiO nanoparticles were prepared via a citrate method and further functionalized with Pd by impregnation. The pure oxides as well as Pd/Fe2O3, Pd/Co3O4, and Pd/NiO (1, 5 and 10 wt % Pd) were employed for catalytic methane combustion under methane lean (1 vol %)/oxygen rich (18 vol %, balanced with nitrogen) conditions. Already, the pure metal oxides showed a high catalytic activity leading to complete conversion temperature of T100 ≤ 500 °C. H2-TPR (Temperature-programmed reduction) experiments revealed that Pd-functionalized metal oxides exhibited enhanced redox activity compared to the pure oxides leading to improved catalytic combustion activity at lower temperatures. At a loading of 1 wt % Pd, 1Pd/Co3O4 (T100 = 360 °C) outperforms 1Pd/Fe2O3 (T100 = 410 °C) as well as 1Pd/NiO (T100 = 380 °C). At a loading of 10 wt % Pd, T100 could only be slightly reduced in all cases. 1Pd/Co3O4 and 1Pd/NiO show reasonable stability over 70 h on stream at T100. XPS (X-ray photoelectron spectroscopy) and STEM (Scanning transmission electron microscopy) investigations revealed strong interactions between Pd and NiO as well as Co3O4, respectively, leading to dynamic transformations and reoxidation of Pd due to solid state reactions, which leads to the high long-term stability. KW - Methane total oxidation KW - Methane removal KW - Carbon dioxide KW - X-ray photoelectron spectroscopy PY - 2018 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-439412 DO - https://doi.org/10.3390/catal8020042 SN - 2073-4344 VL - 8 IS - 2 SP - Article 42, 1 EP - 13 PB - MDPI AN - OPUS4-43941 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - INPR A1 - Tannenberg, Robert A1 - Tscheuschner, Georg A1 - Raab, Christopher A1 - Flemig, Sabine A1 - Döring, Sarah A1 - Ponader, Marco A1 - Thurmann, Melinda A1 - Paul, Martin A1 - Weller, Michael G. T1 - Simplified Sample Preparation and Lateral Flow Immunoassay for the Detection of Plant Viruses N2 - Lateral flow immunoassays (LFA) are widely used for decentralized testing, but their application for in-field plant virus diagnostics is often limited by tedious sample preparation. Here, we present a simplified dipstick LFA for the detection and monitoring of cowpea chlorotic mottle virus (CCMV) as a model plant pathogen. The assay employes a monoclonal mouse antibody for capture and a polyclonal rabbit antibody conjugated to 80-nm gold nanoparticles for detection. Conventional sample and conjugate pads are omitted, allowing the test strips to be dipped directly into wells containing plant extract and antibody-gold conjugate. In addition, no plastic casing was necessary, which significantly reduces waste. It was shown that CCMV concentrations as low as 4 μg/L or 400 pg per sample could be reliably detected in 15 minutes. Specificity tests confirmed that other plant viruses, cowpea mosaic virus (CPMV) and tobacco mosaic virus (TMV), did not produce false positive results. Furthermore, we describe a field-compatible sampling procedure using a manual punch and a disposable syringe. This step combines sample grinding, extraction, and conjugate reconstitution within the syringe frit, enabling the analysis of punched leaf discs without laboratory equipment. When applied to CCMV-infected cowpea plants, the assay revealed systemic infection before visual symptoms became apparent. This work demonstrates that simplified LFAs combined with innovative sampling techniques can provide sensitive, specific, and rapid diagnostics for crop monitoring and support early intervention strategies in agriculture. N2 - Lateral Flow Immunoassays (LFA) werden häufig für dezentrale Tests verwendet, aber ihre Anwendung für die Diagnose von Pflanzenviren im Feld wird oft durch die mühsame Probenvorbereitung eingeschränkt. Hier stellen wir einen vereinfachten Dipstick-LFA zum Nachweis und zur Überwachung des Cowpea Chlorotic Mottle Virus (CCMV) als Modellpflanzenpathogen vor. Der Assay verwendet einen monoklonalen Maus-Antikörper zum Einfangen des Virus und einen polyklonalen Kaninchen-Antikörper, der an 80-nm-Goldnanopartikel konjugiert ist, zum Nachweis. Herkömmliche Proben- und Konjugatpads entfallen, sodass die Teststreifen direkt in Vertiefungen getaucht werden können, die Pflanzenextrakt und Antikörper-Gold-Konjugat enthalten. Darüber hinaus war keine Kunststoffhülle erforderlich, was den Abfall erheblich reduziert. Es zeigte sich, dass CCMV-Konzentrationen von nur 4 μg/L oder 400 pg pro Probe innerhalb von 15 Minuten zuverlässig nachgewiesen werden konnten. Spezifitätstests bestätigten, dass andere Pflanzenviren, das Cowpea Mosaic Virus (CPMV) und das Tobacco Mosaic Virus (TMV), keine falsch positiven Ergebnisse lieferten. Darüber hinaus beschreiben wir ein feldtaugliches Probenahmeverfahren unter Verwendung eines manuellen Stanzers und einer Einwegspritze. Dieser Schritt kombiniert das Zerkleinern der Probe, die Extraktion und die Rekonstitution des Konjugats innerhalb der Spritzenfritte und ermöglicht so die Analyse von ausgestanzten Blattscheiben ohne Laborausrüstung. Bei der Anwendung auf CCMV-infizierte Augenbohnenpflanzen zeigte der Test eine systemische Infektion, bevor visuelle Symptome sichtbar wurden. Diese Arbeit zeigt, dass vereinfachte LFAs in Kombination mit innovativen Probenahmetechniken eine sensitive, spezifische und schnelle Diagnostik für die Überwachung von Nutzpflanzen ermöglichen und frühzeitige Interventionsstrategien in der Landwirtschaft unterstützen können. KW - Vigna unguiculata KW - Cowpea KW - Sample preparation KW - Plant pathogen KW - Mobile detection KW - Crop monitoring KW - Plastic waste KW - Lateral flow immunoassay KW - Plant virus KW - Sample pad KW - Conjugate pad PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-651731 DO - https://doi.org/10.20944/preprints202512.1492.v1 SP - 1 EP - 14 PB - MDPI CY - Basle, Switzerland AN - OPUS4-65173 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Steglich, P. A1 - Rabus, D. G. A1 - Sada, C. A1 - Paul, Martin A1 - Weller, Michael G. A1 - Mai, C. A1 - Mai, A. T1 - Silicon Photonic Micro-Ring Resonators for Chemical and Biological Sensing: A Tutorial N2 - Silicon photonic micro-ring resonators (MRR) developed on the silicon-on-insulator (SOI) platform, owing to their high sensitivity and small footprint, show great potential for many chemical and biological sensing applications such as label-free detection in environmental monitoring, biomedical engineering, and food analysis. In this tutorial,we provide the theoretical background and give design guidelines for SOI-based MRR as well as examples of surface functionalization procedures for label-free detection of molecules. After introducing the advantages and perspectives of MRR, fundamentals of MRR are described in detail, followed by an introduction to the fabrication methods, which are based on a complementary metal-oxide semiconductor (CMOS) technology. Optimization of MRR for chemical and biological sensing is provided, with special emphasis on the optimization of waveguide geometry. At this point, the difference between chemical bulk sensing and label-free surface sensing is explained, and definitions like waveguide sensitivity, ring sensitivity, overall sensitivity as well as the limit of detection (LoD) of MRR are introduced. Further, we show and explain chemical bulk sensing of sodium chloride (NaCl) in water and provide a recipe for label-free surface sensing. KW - Biosensors KW - Biophotonics KW - Chemosensor KW - Biosensor KW - Microresonator KW - Nanophotonics KW - Optical sensors KW - Photonic sensors KW - Optoelectronic KW - Ring resonator KW - Silicon photonics KW - Miniaturization KW - Lab-on-a-chip KW - Lab-on-chip KW - Waveguide KW - Surface chemistry KW - Silanization KW - Glutaraldehyde KW - Affinity immobilization KW - Antibody KW - Oriented immobilization KW - Real-time measurement PY - 2022 DO - https://doi.org/10.1109/JSEN.2021.3119547 SN - 1530-437X VL - 22 IS - 11 SP - 10089 EP - 10105 PB - IEEE AN - OPUS4-55147 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bornemann-Pfeiffer, Martin A1 - Wolf, Jakob A1 - Meyer, Klas A1 - Kern, S. A1 - Angelone, D. A1 - Leonov, A. A1 - Cronin, L. A1 - Emmerling, Franziska T1 - Standardization and control of Grignard reactions in a universal chemical synthesis machine using online NMR T1 - Standardisierung und Kontrolle von Grignard-Reaktionen mittels Online-NMR in einer universellen chemischen Syntheseplattform N2 - A big problem with the chemistry literature is that it is not standardized with respect to precise operational parameters, and real time corrections are hard to make without expert knowledge. This lack of context means difficult reproducibility because many steps are ambiguous, and hence depend on tacit knowledge. Here we present the integration of online NMR into an automated chemical synthesis machine (CSM aka. “Chemputer” which is capable of small-molecule synthesis using a universal programming language) to allow automated analysis and adjustment of reactions on the fly. The system was validated and benchmarked by using Grignard reactions which were chosen due to their importance in synthesis. The system was monitored in real time using online-NMR, and spectra were measured continuously during the reactions. This shows that the synthesis being done in the Chemputer can be dynamically controlled in response to feedback optimizing the reaction conditions according to the user requirements. N2 - Ein Problem der chemischen Literatur ist die fehlende Standardisierung bezüglich genauer Bedingungen, auch Echtzeit-Korrekturen sind ohne Expertenwissen nur schwer möglich. Dieser Mangel an Details erschwert experimentelle Reproduzierbarkeit, da Schritte oft mehrdeutig sind und daher von implizitem Wissen abhängen. Hier präsentieren wir die Integration von Online-NMR Spektroskopie in eine automatisierte chemische Syntheseplattform (CSM aka. “Chemputer”, unter Verwendung einer universellen Programmiersprache zur Synthese kleiner Moleküle fähig), um eine automatisierte Analyse und Anpassung von Reaktionen im laufenden Betrieb zu ermöglichen. Das System wurde anhand von Grignard-Reaktionen, die aufgrund ihrer Bedeutung für die Synthese ausgewählt wurden, validiert und einem Härtetest unterzogen. Synthesen wurden in Echtzeit mit Online-NMR überwacht, und die Spektren wurden während der Reaktionen kontinuierlich aufgenommen und analysiert. Dies zeigt, dass der Chemputer dynamisch mittels einer Regelung kontrolliert werden kann, um die Reaktionsbedingungen entsprechend den Anforderungen des Benutzers zu optimieren. KW - Grignard reaction KW - NMR spectroscopy KW - Process analytical technology KW - Process control KW - Grignard-Reaktion KW - NMR-Spektroskopie KW - Prozessanalytik KW - Prozesskontrolle PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-531260 DO - https://doi.org/10.1002/anie.202106323 SN - 1521-3773 SN - 1433-7851 N1 - Bibliografische Angaben für die deutsche Version: Angewandte Chemie 2021, Jg. 133, S. 1–7, ISSN 0044-8249, ISSN 1521-3757, https://doi.org/10.1002/ange.202106323 - Bibliographic information for the German version: Angewandte Chemie 2021, vol. 133, p. 1–7, ISSN 0044-8249, ISSN 1521-3757, https://doi.org/10.1002/ange.202106323 VL - 60 IS - 43 SP - 1 EP - 6 PB - Wiley-VCH CY - Weinheim AN - OPUS4-53126 LA - mul AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - de Oliveira Guilherme Buzanich, Ana A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich A1 - Emmerling, Franziska ED - de Oliveira Guilherme Buzanich, Ana ED - Strange, R. W. T1 - Time- and spatial-resolved XAFS spectroscopy in a single shot: new analytical possibilities for in situ material characterization N2 - A new concept that comprises both time- and lateral-resolved X-ray absorption fine-structure information simultaneously in a single shot is presented. This uncomplicated set-up was tested at the BAMline at BESSY-II (Berlin, Germany). The primary broadband beam was generated by a double multilayer monochromator. The transmitted beam through the sample is diffracted by a convexly bent Si (111) crystal, producing a divergent beam. This, in turn, is collected by either an energy-sensitive area detector, the so-called color X-ray camera, or by an area-sensitive detector based on a CCD camera, in θ–2θ geometry. The first tests were performed with thin metal foils and some iron oxide mixtures. A time resolution of lower than 1 s together with a spatial resolution in one dimension of at least 50 mm is achieved. KW - Single-shot XAFS KW - Time resolution PY - 2016 UR - http://scripts.iucr.org/cgi-bin/paper?S1600577516003969 DO - https://doi.org/10.1107/S1600577516003969 SN - 1600-5775 VL - 23 SP - 769 EP - 776 PB - International Union of Crystallography CY - Liverpool, UK AN - OPUS4-35903 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - de Oliveira Guilherme Buzanich, Ana A1 - Cakir, Cafer Tufan A1 - Radtke, Martin A1 - Haider, M. Bilal A1 - Emmerling, Franziska A1 - F. M. Oliveira, P. A1 - Michalchuk, Adam T1 - Dispersive x-ray absorption spectroscopy for time-resolved in situ monitoring of mechanochemical reactions N2 - X-ray absorption spectroscopy (XAS) provides a unique, atom-specific tool to probe the electronic structure of solids. By surmounting long-held limitations of powder-based XAS using a dynamically averaged powder in a Resonant Acoustic Mixer (RAM), we demonstrate how time-resolved in situ (TRIS) XAS provides unprecedented detail of mechanochemical synthesis. The use of a custom-designed dispersive XAS (DXAS) setup allows us to increase the time resolution over existing fluorescence measurements from ∼15 min to 2 s for a complete absorption spectrum. Hence, we here establish TRIS-XAS as a viable method for studying mechanochemical reactions and sampling reaction kinetics. The generality of our approach is demonstrated through RAM-induced (i) bottom-up Au nanoparticle mechanosynthesis and (ii) the synthesis of a prototypical metal organic framework, ZIF-8. Moreover, we demonstrate that our approach also works with the addition of a stainless steel milling ball, opening the door to using TRIS-DXAS for following conventional ball milling reactions. We expect that our TRIS-DXAS approach will become an essential part of the mechanochemical tool box. KW - In situ studies KW - Dipsersive XAS KW - Mechanochemistry KW - Time-resolved PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-567659 DO - https://doi.org/10.1063/5.0130673 SN - 1089-7690 VL - 157 IS - 21 SP - 1 EP - 12 PB - American Institute of Physics CY - Melville, NY AN - OPUS4-56765 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Steglich, P. A1 - Bondarenko, S. A1 - Mai, C. A1 - Paul, Martin A1 - Weller, Michael G. A1 - Mai, A. T1 - CMOS-Compatible Silicon Photonic Sensor for Refractive Index Sensing Using Local Back-Side Release N2 - Silicon photonic sensors are promising candidates for lab-on-a-chip solutions with versatile applications and scalable production prospects using complementary metal-oxide semiconductor (CMOS) fabrication methods. However, the widespread use has been hindered because the sensing area adjoins optical and electrical components making packaging and sensor handling challenging. In this work, a local back-side release of the photonic sensor is employed, enabling a separation of the sensing area from the rest of the chip. This approach allows preserving the compatibility of photonic integrated circuits in the front-end of line and metal interconnects in the back-end of line. The sensor is based on a micro-ring resonator and is fabricated on wafer-level using a CMOS technology. We revealed a ring resonator sensitivity for homogeneous sensing of 106 nm/RIU. KW - Photonic biosensor KW - Lab-on-a-chip KW - Ring resonator KW - Resonance wavelength shift KW - PIC technology KW - Back-side integration PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-517139 DO - https://doi.org/10.1109/LPT.2020.3019114 VL - 32 IS - 19 SP - 1241 EP - 1244 PB - IEEE AN - OPUS4-51713 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Paul, Martin T1 - Development of a biosensor for the online detection of explosives N2 - An affinity column, which removed up to 99 % of high affinity Anti-TNT antibody at high antibody concentrations, was manufactured based on a monolithic glass core and a trinitroaniline-BSA conjugate. To detect the label Dy654 in the nM range an epi-fluorescence microscope setup with a CMOS camera was established to serve as online fluorescence detector with multiplexing capabilities. T2 - ANAKON 2019 CY - Münster, Germany DA - 25.03.2019 KW - Online fluorescence KW - Trinitro KW - Affinty KW - Antibody PY - 2019 AN - OPUS4-47745 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Paul, Martin T1 - Fast Detection of TNT at ppt Level by an Immunofluorometric Biosensor N2 - The mechanism of this system is based on kinetic competition. This biosensor consists of a monolithic glass column with a vast excess of immobilized hapten, which traps the fluorescently labeled antibody as long as no explosive is present. If the explosive 2,4,6-trinitrotoluene (TNT) is introduced some binding sites of the antibody will be blocked, which leads to an immediate breakthrough of the labeled protein. The fluorescence is detected by highly sensitive laser-induced fluorescence with a conventional CMOS camera. The system achieved limits of detection of approx.1 pM (1 ppt) of the fluorescent label and around 100 pM (20 ppt) of TNT. The total assay time is less than 8 minutes. A cross-reactivity test with 5000 pM solutions of pentaerythritol tetranitrate (PETN), 1,3,5-trinitroperhydro-1,3,5-triazine (RDX), and octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX) showed no cross reactivity. T2 - Doktorandenseminar 2020 des Arbeitskreis-Prozessanalytik CY - Online meeting DA - 21.09.2020 KW - TNT KW - Explosive KW - Antibody KW - Fluorescence KW - Biosensor KW - Affinity PY - 2020 AN - OPUS4-51314 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Paul, Martin T1 - Real time multichannel biomarker detection using photonic integrated circuits on ultra compact CMOS chips N2 - This work presents the real-time, multichannel detection of the biomolecule Neutravidine using photonic integrated circuits on ultra-compact monolithic CMOS chips. The development focuses on implementing bioassays directly on CMOS platforms, enabling highly integrated and scalable biosensing. The presentation will cover key aspects including microfluidic integration, data analysis, surface functionalization, and chip packaging. T2 - World Biosensor Congress CY - Lisbon, Portugal DA - 18.05.2025 KW - Chips KW - Photonics KW - Biosensor KW - Realtime PY - 2025 AN - OPUS4-63777 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Tannenberg, Robert A1 - Paul, Martin A1 - Röder, Bettina A1 - Gande, S. L. A1 - Sreeramulu, S. A1 - Saxena, K. A1 - Richter, C. A1 - Schwalbe, H. A1 - Swart, C. A1 - Weller, Michael G. T1 - Chemiluminescence biosensor for the determination of cardiac troponin I (cTnI) N2 - Cardiac troponin I (cTnI) is a crucial biomarker for diagnosing cardiac vascular diseases, including acute myocardial infarction (AMI). This study presents a proof-of-concept chemiluminescence-based immunosensor for rapid and accurate measurement of cTnI, with the potential for online monitoring. The immunosensor incorporates a flow cell design and a sensitive complementary metal-oxide-semiconductor (CMOS) camera for optical readout. A microfluidic setup was established to enable selective and quasi-online determination of cTnI within ten minutes. The sensor was tested with recombinant cTnI in phosphate buffer, demonstrating measurements in the concentration range of 2–25 µg/L, with a limit of detection (LoD) of 0.6 µg/L (23 pmol/L) achieved using the optimized system. The immunosensor exhibited high selectivity, as no cross-reactivity was observed with other recombinant proteins such as cTnT and cTnC at a concentration of 16 µg/L. Measurements with diluted blood plasma and serum yielded an LoD of 60 µg/L (2.4 nmol/L) and 70 µg/L (2.9 nmol/L), respectively. This biosensor offers a promising approach for the rapid and sensitive detection of cTnI, contributing to the diagnosis and management of acute myocardial infarction and other cardiac vascular diseases. N2 - Das kardiale Troponin I (cTnI) ist ein wichtiger Biomarker für die Diagnose von Herz-Kreislauf-Erkrankungen, einschließlich des akuten Myokardinfarkts (AMI). In dieser Studie wird ein auf Chemilumineszenz basierender Immunsensor für die schnelle und genaue Messung von cTnI vorgestellt, der das Potenzial für eine Online-Überwachung hat. Der Immunsensor besteht aus einer Durchflusszelle und einer empfindlichen CMOS-Kamera (Complementary Metal-Oxide-Semiconductor) zur optischen Detektion. Es wurde ein mikrofluidischer Aufbau entwickelt, der eine selektive und quasi Online-Bestimmung von cTnI innerhalb von zehn Minuten ermöglicht. Der Sensor wurde mit rekombinantem cTnI in Phosphatpuffer getestet und zeigte einen Messbereich von 2-25 µg/L, wobei mit dem optimierten System eine Nachweisgrenze (LoD) von 0,6 µg/L (23 pmol/L) erreicht wurde. Der Immunsensor zeigte eine hohe Selektivität, da keine Kreuzreaktivität mit anderen rekombinanten Proteinen wie cTnT und cTnC bei einer Konzentration von 16 µg/L beobachtet wurde. Messungen mit verdünntem Blutplasma und Serum ergaben einen LoD von 60 µg/L (2,4 nmol/L) bzw. 70 µg/L (2,9 nmol/L). Dieser Biosensor bietet einen vielversprechenden Ansatz für den schnellen und empfindlichen Nachweis von cTnI, der zur Diagnose und Behandlung des akuten Myokardinfarkts und anderer kardialer Gefäßerkrankungen beitragen kann. KW - Acute myocardial infarction KW - Heart attack KW - Emergency KW - Diagnosis KW - Cardiac troponin KW - Biomarker KW - Immunosensor KW - Biosensor KW - Chemiluminescence KW - Luminol KW - Peroxidase KW - Monoclonal antibodies KW - Flow injection immunoassay KW - Immunometric assay KW - Immunometric biosensor KW - Microfluidic system KW - Monolithic column KW - Online biosensor PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-575471 DO - https://doi.org/10.3390/bios13040455 SN - 2079-6374 VL - 13 IS - 4 SP - 1 EP - 20 PB - MDPI CY - Basel AN - OPUS4-57547 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Paul, Martin A1 - Weller, Michael G. T1 - Antibody screening by microarray technology - Direct identification of selective high-affinity clones N2 - The primary screening of hybridoma cells is a time-critical and laborious step during the development of monoclonal antibodies. Often, critical errors occur in this phase, which supports the notion that the generation of monoclonal antibodies with hybridoma technology is difficult to control and hence, a risky venture. We think that it is crucial to improve the screening process to eliminate most of the critical deficits of the conventional approach. With this new microarray-based procedure, several advances could be achieved: Selectivity for excellent binders, high-throughput, reproducible signals, avoidance of misleading avidity (multivalency) effects, and performance of simultaneous competition experiments. The latter can also be used to select clones of desired cross-reactivity properties. In this paper, a model system with two excellent clones against carbamazepine, two weak clones, and blank supernatant containing fetal bovine serum was designed to examine the effectiveness of the new system. The excellent clones could be detected largely independent of the immunoglobulin G (IgG) concentration, which is usually unknown during the clone screening since the determination and subsequent adjustment of the antibody concentration are not feasible in most cases. Furthermore, in this approach, the enrichment, isolation, and purification of IgG for characterization is not necessary. Raw cell culture supernatant can be used directly, even when fetal calf serum (FCS) or other complex media is used. In addition, an improved method for the oriented antibody-immobilization on epoxy-silanized slides is presented. Based on the results of this model system with simulated hybridoma supernatants, we conclude that this approach should be preferable to most other protocols leading to many false positives, causing expensive and lengthy elimination steps to weed out the poor clones. KW - ELISA KW - Immunoassay KW - Microarray KW - Lab-on-a-chip KW - Miniaturization KW - Aautomatisation KW - HTS KW - High-throughput KW - Screening KW - Fluorescence KW - Label KW - Hybridoma KW - Inhibition PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-503361 DO - https://doi.org/10.3390/antib9010001 SN - 2073-4468 VL - 9 IS - 1 SP - 1 EP - 16 PB - MDPI CY - Basel AN - OPUS4-50336 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Tannenberg, Robert A1 - Paul, Martin A1 - Fünning, Tabea A1 - Schuhmann, Christoph A1 - Weller, Michael G. A1 - Steglich, Patrick T1 - Multichannel real-time detection of biomarkers with highly miniaturized photonic microchips N2 - The development of novel photonic integrated microchips (PIC) is a promising approach to allow for the convenient detection of key biomarkers in complex matrices through multichannel real-time analysis in a highly compact package. This study reports the successful development and application of a backside released CMOS chip designed for the multichannel real-time detection of biomarkers. Operating at the C-band at approx. 1550 nm, the microchip features three dedicated detection sensors in addition to a reference sensor, enabling simultaneous analysis of multiple biomarkers. The compact and highly miniaturized design of this microchip, with a footprint of just 1 mm², positions it as promising candidate for point-of-care diagnostics and personalized medicine applications. This technology opens a path to transform biomarker detection across various medical fields, offering rapid, reliable, and cost-effective diagnostic solutions. In conclusion, the presented multichannel photonic microchips signify a substantial leap forward in real-time biomarker detection, providing a highly capable platform for future research and clinical applications. T2 - SPIE Optics + Optoelectronics 2025 CY - Prague, Czech Republic DA - 07.04.2025 KW - Photonic integrated circuit KW - Ring resonator KW - Real-time detection KW - Multiplexing KW - Semiconductor KW - CMOS KW - C-reactive protein KW - CRP KW - Biomarker PY - 2025 SN - 978-1-5106-8850-6 DO - https://doi.org/10.1117/12.3056453 VL - 13527 SP - 1 EP - 6 PB - SPIE CY - Prague, Czech Republic AN - OPUS4-63478 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Paul, Martin T1 - High sensitivity online detection of Trinitrotoluene (TNT) N2 - The antibody A.1.1.1 was labeled and found to be very sensitive and highly selective for TNT. A novel monolithic affinity column was coated with a Trinitroaniline (TNA)-BSA affinity conjugate and a custom laser induced fluorescence detector were built to allow for continuous and sensitive detection. The affinity column combined with the high sensitivity detector resulted in a limit of detection of approx. 100 pM TNT or 20 ppt TNT for offline detection and was able to detect picogram amounts within three minutes. T2 - SALSA Make and Measure 2020 CY - Online meeting DA - 15.10.2020 KW - Biosensor KW - Explosive KW - Antibody KW - Online KW - Fluorescence PY - 2020 AN - OPUS4-51529 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Steglich, Patrick A1 - Paul, Martin A1 - Mai, C. A1 - Böhme, A. A1 - Bondarenko, S. A1 - Weller, Michael G. A1 - Mai, A. T1 - A monolithically integrated microfluidic channel in a silicon-based photonic-integrated-circuit technology for biochemical sensing N2 - In this work, a cost-effective optofluidic system is proposed and preliminary experimental results are presented. A microfluidic channel monolithically integrated into a photonic integrated circuit technology is used in conjunction with a cyclic olefin copolymer (COC) substrate to provide fluidic in- and output ports. We report on initial experimental results as well as on the simple and cost-effective fabrication of this optofluidic system by means of micro-milling. KW - Biosensors KW - Biophotonics KW - Optical sensors KW - Photonic sensors KW - Ring resonators KW - Silicon photonics KW - Lab-on-a-chip KW - Microfluidics KW - Chip KW - Biochip PY - 2021 DO - https://doi.org/10.1117/12.2588791 VL - 11772 SP - 1 EP - 5 PB - SPIE AN - OPUS4-53559 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Steglich, P. A1 - Mai, C. A1 - Bondarenko, S. A1 - Paul, Martin A1 - Weller, Michael G. A1 - Schrader, S. A1 - Mai, A. T1 - BioPIC - Integration of Biosensors based on Photonic Integrated Circuits by Local-Backside Etching N2 - Silicon photonic sensors are promising candidates for lab-on-a-chip solutions with versatile applications and scalable production prospects using complementary metal-oxide semiconductor (CMOS) fabrication methods. However, the widespread use has been hindered because the sensing area adjoins optical and electrical components making packaging and sensor handling challenging. In this work, a local back-side release of the photonic sensor is employed, enabling a separation of the sensing area from the rest of the chip. This approach allows preserving the compatibility of photonic integrated circuits in the front-end of line and metal interconnects in the back-end of line. T2 - ATTRACT online Conference CY - Online meeting DA - 22.09.2020 KW - Silicon Photonics KW - Photonic Sensor KW - Photonic Integrated Circuits KW - Point-Of-Care-Diagnostics KW - CMOS KW - Microfluidics KW - Lab-on-a-chip KW - Ring resonator PY - 2020 UR - https://attract-eu.com/showroom/project/integration-of-biosensors-based-on-photonic-integrated-circuits-by-local-backside-etching-biopic/ SP - 1 EP - 5 AN - OPUS4-51735 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Paul, Martin T1 - Multichannel biomarker detection using photonic integrated circuits on ultra compact CMOS chips N2 - This work presents the development of a real-time, multichannel detector for biomolecules based on photonic integrated circuits with super-compact CMOS chips. The presentation focuses on using micro-ring-resonators for bioassays, enabling highly integrated and scalable biosensing-solutions. The talk also covers major challenges like including microfluidic integration, data analysis, custom surface functionalization, and chip packaging. T2 - Photonics Week 2025 CY - Berlin, Germany DA - 08.10.2025 KW - CMOS KW - Photonics KW - Biosensor KW - Immunoassay KW - Realtime PY - 2025 AN - OPUS4-64585 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - INPR A1 - Paul, Martin A1 - Weller, Michael G. T1 - Antibody screening by microarray technology – Direct identification of selective high-affinity clones N2 - The primary screening of hybridoma cells is a time-critical and laborious step during the development of monoclonal antibodies. Often critical errors occur in this phase, which supports the notion that the generation of monoclonal antibodies with hybridoma technology is difficult to control and hence a risky venture. We think that it is crucial to improve the screening process to eliminate most of the immanent deficits of the conventional approach. With this new microarray-based procedure, several advances could be achieved: Selectivity for excellent binders, high throughput, reproducible signals, avoidance of misleading avidity (multivalency) effects, and simultaneous performance of competition experiments. The latter can directly be used to select clones of desired cross-reactivity properties. In this paper, a model system with two excellent clones against carbamazepine, two weak clones and blank supernatant has been designed to examine the effectiveness of the new system. The excellent clones could be detected largely independent of the IgG concentration, which is unknown during the clone screening since the determination and subsequent adjustment of the antibody concentration is not possible in most cases. Furthermore, in this approach, the enrichment, isolation, and purification of IgG for characterization is not necessary. Raw cell culture supernatant can be used directly, even when fetal calf serum (FCS) or other complex media had been used. In addition, an improved method for the oriented antibody-immobilization on epoxy-silanized slides is presented. Based on the results of this model system, we conclude that this approach should be preferable to most other protocols leading to many of false positives, causing expensive and lengthy confirmation steps to weed out the poor clones. KW - Hybridoma KW - Monoclonal Antibodies KW - Clones KW - Competitive Immunoassay KW - Hapten Immunoassay KW - False Positives PY - 2019 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-506621 DO - https://doi.org/10.20944/preprints201911.0023.v1 SN - 2310-287X SP - 1 EP - 17 PB - MDPI CY - Basel AN - OPUS4-50662 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dorau, Kristof A1 - Rückamp, Daniel A1 - Weber, Christian A1 - Scheeder, Georg A1 - Reßing, Ronja A1 - Peth, Stephan A1 - Otto, Philipp A1 - Altmann, Korinna A1 - Fries, Elke A1 - Hoppe, Martin T1 - Characterization and spatial distribution of mesoplastics in an arable soil N2 - AbstractExtraction of plastic particles from soil is challenging and, thus, exceptionally little spatial information on plastic distribution at the field scale has been gathered. However, for environmental risk assessment, adequate sampling should complement coherent plastic profiling. In this study, we investigated the spatial distribution of mesoplastics (MePs; from 5 mm up to 130 mm) in arable soil (Haplic Cambisol) managed intensively by 12 years of compost application. Geo‐referenced samples (n = 128) and five different sampling designs (n = 45) of variable sampling volume (from 2 to 300 L) were collected at a three hectare study site in Northern Germany (0–30 cm soil depth). Soil properties such as pH and soil organic carbon (SOC) were measured to evaluate dispersion measures of these data. In total, we found 259 MePs with a predominance of transparent packaging foils made of polyethylene and coloured fibres of polypropylene. Average particle metrics were a projection area of 47 (3–400) mm2, a Feret diameter of 18.5 (5.4–130) mm and a mass of 1.89 (0.11–221) mg. Caution is advised when measuring the particle mass due to still strongly adhering soil material, especially for fibre bundles with 0.544 mg soil mg−1 particle. We recommend using a 0.1 mol L−1 tetrasodium pyrophosphate solution to purify MePs by removing attached soil before weighing for further environmental risk assessment. The MePs count with a median value of 0.50 (0–3.2) particles kg−1 and median mass of 2.26 (0–221) mg kg−1 featured the highest coefficient of variation (CV) with 103% and 187%, respectively. This is 10–20 times larger in comparison to the CV of SOC (9.2%) and even 50–93 times larger than CV of soil pH (2.2%). This leads to the need of larger sample numbers to delineate plastic metrics in comparison with soil properties to identify a reliable mean value of the field within a predefined allowable error. Mesoplastics in the soil were characterized by a pure nugget effect variogram (no spatial correlation), revealed no intrafield variability and the sample volume yielded inconclusive results. Sampling for plastics in soil should either (i) drastically increase the sample number for a single field or (ii) communicate transparently that the allowable error is by far enhanced in comparison with classical soil properties like pH and SOC. More systematic studies featuring geo‐spatial analysis of MePs and smaller‐sized plastics in soils are required to propose adequate sampling designs across multiple land uses and plastics fingerprints. A larger database would, thereupon, pave the way for best‐practice guides on how to treat ‘outliers’ and search for robust estimators for spatial mapping of plastics in soils. KW - Large microplastics KW - Microplastics PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-617772 DO - https://doi.org/10.1111/ejss.70016 VL - 75 IS - 6 SP - 1 EP - 16 PB - Wiley AN - OPUS4-61777 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - de Oliveira Guilherme Buzanich, Ana A1 - Radtke, Martin A1 - Emmerling, Franziska ED - Rogge, Andreas ED - Meng, Birgit T1 - Exploring new materials for Green Intelligent Building - How can our BAMline help? N2 - In the scope of exploring and characterizing new materials related to Green Intelligent Building (GIB), we will provide an overview of the X-ray spectroscopy and diffraction analytical methods available at the BAMline /1/. and Myspot beamlines. These are two universal beamlines at the Berlin Synchrotron BESSY-II, where BAM has access and supervision role. Overarching electronic and structural properties at different time and length scales, such measurements enable a real-time characterization of materials properties. We will show-case in situ and ex situ deterioration and hydration studies on cement-based constructure materials. T2 - 11. Jahrestagung des DAfStb mit 63. Forschungskolloquium der BAM Green Intelligent Building CY - Berlin, Germany DA - 16.10.2024 KW - BAMline KW - Scope of exploring KW - Green intelligent building PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-612882 SN - 978-3-9818564-7-7 SP - 30 EP - 36 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-61288 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dittmar, Stefan A1 - Weyrauch, Steffen A1 - Reemtsma, Thorsten A1 - Eisentraut, Paul A1 - Altmann, Korinna A1 - Ruhl, Aki S. A1 - Jekel, Martin T1 - Settling Velocities of Tire and Road Wear Particles: Analyzing Finely Graded Density Fractions of Samples from a Road Simulator and a Highway Tunnel N2 - The terminal settling velocity is considered the most critical parameter determining the transport of tire and road wear particles (TRWP) in aquatic environments. Nonetheless, no respective empirical data has been reported so far. In this study, particle samples from a road simulator and a highway tunnel were investigated with a validated imaging method. Different density and size fractions of both samples were measured separately, acquiring sizes and settling velocities of more than 30,000 individual particles. In addition, tire marker polymers were analyzed for each fraction via thermal extraction desorption-gas chromatography/mass spectrometry. Finally, the acquired particle data was combined according to the fractions’ estimated tire contents in order to deduce detailed probability distributions of particle size and settling velocity for the actual TRWP from both samples. Weighted by TRWP-incorporated tire mass, median diameters of 54 and 44 μm as well as median settling velocities of 0.65 and 0.22 mm/s were found for TRWP from the road simulator and highway tunnel, respectively. This study thus provides the first ever empirical data on TRWP settling velocities in water, which can be highly valuable input for modeling the environmental transport of TRWP and for dimensioning TRWP retention systems. KW - Microplastics KW - TED-GC/MS KW - Sinking velocities KW - Transport PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-635449 DO - https://doi.org/10.1021/acs.est.5c04165 SN - 0013-936X VL - 59 IS - 26 SP - 13434 EP - 13446 PB - American Chemical Society (ACS) AN - OPUS4-63544 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Das, Prasenjit A1 - Chakraborty, Gouri A1 - Yang, Jin A1 - Roeser, Jérôme A1 - Küçükkeçeci, Hüseyin A1 - Nguyen, Anh Dung A1 - Schwarze, Michael A1 - Gabriel, Jose A1 - Penschke, Christopher A1 - Du, Shengjun A1 - Weigelt, Vincent A1 - Khalil, Islam E. A1 - Schmidt, Johannes A1 - Saalfrank, Peter A1 - Oschatz, Martin A1 - Rabeah, Jabor A1 - Schomäcker, Reinhard A1 - Emmerling, Franziska A1 - Thomas, Arne T1 - The Effect of Pore Functionality in Multicomponent Covalent Organic Frameworks on Stable Long‐Term Photocatalytic H2 Production N2 - AbstractIn nature, organic molecules play a vital role in light harvesting and photosynthesis. However, regarding artificial water splitting, the research focus is primarily on inorganic semiconductors. Although organic photocatalysts have high structural variability, they tend to exhibit lower quantum efficiencies for water splitting than their inorganic counterparts. Multicomponent reactions (MCRs) offer an attractive route to introduce different functional units into covalent organic frameworks (COFs) and enable semiconducting properties and high chemical stability, creating promising materials for long‐term photocatalytic applications, such as H2 production. Herein, five highly crystalline donor‐acceptor based, 4‐substituted quinoline‐linked MCR‐COFs are presented that are prepared via the three‐component Povarov reaction. The pore functionality is varied by applying different vinyl derivatives (e.g., styrene, 2‐vinyl pyridine, 4‐vinylpyridine, 4‐vinyl imidazole, 2,3,4,5,6‐pentafluorostyrene), which has a strong influence on the obtained photocatalytic activity. Especially an imidazole‐functionalized COF displays promising photocatalytic performance due to its high surface area, crystallinity, and wettability. These properties enable it to maintain its photocatalytic activity even in a membrane support. Furthermore, such MCR‐COFs display dramatically enhanced (photo)chemical stability even after long‐term solar light irradiation and exhibit a high and steady H2 evolution for at least 15 days. KW - Sstability KW - Covalent organic frameworks KW - Pore functionality KW - Long-term H2 production KW - Multicomponent reactions PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-639787 DO - https://doi.org/10.1002/aenm.202501193 SN - 1614-6832 SP - 1 EP - 10 PB - Wiley VHC-Verlag AN - OPUS4-63978 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Paul, Martin T1 - Microarrays for the screening of monoclonal antibodies from supernatants N2 - In this thesis a protocol based on a direct competitive and non-competitive immunoassay using the microarray format was developed to screen emulated hybridoma supernatants against the drug carbamazepine (CBZ). As support, epoxy slides were manufactured by coating microscope glass slides with epoxy silanes. The manufactured epoxy slides showed similar capacity for protein immobilization as commercially available NEXTERION slides, but showed a higher autofluorescence background. On the epoxy slides, protein A, Cys-A, G and Cys-G were immobilized as antibody capturing coating. It could be shown that the Cys-tag considerably increased the immobilization of all compared proteins, especially of protein G. Protein Cys-G immobilized at pH 8-9 was considered the most suitable protein for antibody immobilization due to good spot uniformity and a high binding capacity for IgG. Additionally, in immobilization experiments it could be shown, that 10-500 fold excess of bovine IgG, introduced by two different fetal bovine serum (FBS) products, showed no significant competition on the immobilization of mice or goat IgG on protein Cys-G. To examine the captured antibodies for affinity to CBZ, the CBZ-TOTA-DY654 tracer was custom synthesized. It could be demonstrated, that the tracer antibody interaction was competitive with the tracer precursor, CBZ-TOTA-NH2 and CBZ. Furthermore, the synthesized tracer was also successfully used by externals to evaluate CBZ affine hybriodoma cells in flow cytometry. In the simulated screening, five antibodies with known affinity to CBZ were diluted in a cell culture medium. The screening method allowed to differentiate between affine antibodies (IC50 < 20 µg/ml) and unaffine antibodies (IC50 > 20 µg/ml), when concentrations of 0.1 µg/ml IgG or greater have been used. Of five applied antibodies, all highly affine clones (CE2 and B3212M) were reported as positives while no false-positive samples were observed. The screening included competitive, with around 89500 fold excess of CBZ, and non-competitive tracer incubation on different segments of the same chip, which resulted in total signal suppression on the competitive segment. The screening was performed in 20 hours, only a few nanoliters, of each simulated supernatant, were consumed in the screening process, furthermore in the method standard 96 well MTPs were used and no cleanroom facilities were required. KW - Carbamazepine KW - Microscopic slides KW - Protein A cys KW - Competition KW - Epoxy silanes KW - Supernatant KW - Antibody immobilization PY - 2017 SP - 1 EP - 96 PB - Humboldt-Universität zu Berlin CY - Berlin AN - OPUS4-54645 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Paul, Martin T1 - Development of a high-sensitivity biosensor for the quasi-continuous detection of the explosive TNT and the illegal drug cocaine N2 - An immunofluorometric biosensor with laser-induced fluorescence detection was presented. For TNT an LOD of 60 ppb and for cocaine an LOD of 9 ppb was achieved. A swipe test was performed in less than 3 minutes. No significant cross-reactivity was observed. T2 - 15. Interdisziplinäres Doktorandenseminar des Arbeitskreises Prozessanalytik der GDCh CY - Online meeting DA - 06.09.2021 KW - PETN KW - HMX KW - RDX KW - Microfluidic mixing KW - Lab-on-a-chip KW - Affinity column KW - Monolithic material KW - Sintered glass KW - Dy-654 KW - Flowcell KW - Epifluorescence KW - CMOS camera KW - Diode laser KW - Antibody screening PY - 2021 AN - OPUS4-53329 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Peters, Stefan A1 - Kunkel, Benny A1 - Cakir, Cafer Tufan A1 - Kabelitz, Anke A1 - Witte, Steffen A1 - Bernstein, Thomas A1 - Bartling, Stephan A1 - Radtke, Martin A1 - Emmerling, Franziska A1 - Abdel-Mageed, Ali Mohamed A1 - Wohlrab, Sebastian A1 - de Oliveira Guilherme Buzanich, Ana T1 - Time-, space- and energy-resolved in situ characterization of catalysts by X-ray absorption spectroscopy N2 - A novel setup for dispersive X-ray absorption spectroscopy (XAS) with simultaneous resolution of space, time and energy for in situ characterization of solid materials is demonstrated. KW - Dispersive XAS KW - Catalysis KW - In situ KW - Structure analysis PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-584924 DO - https://doi.org/10.1039/d3cc03277a SN - 1359-7345 SP - 1 EP - 4 PB - Royal Society of Chemistry (RSC) AN - OPUS4-58492 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Paul, Martin A1 - Tscheuschner, Georg A1 - Herrmann, Stefan A1 - Weller, Michael G. T1 - Fast Detection of 2,4,6-Trinitrotoluene (TNT) at ppt Level by a Laser-Induced Immunofluorometric Biosensor N2 - The illegal use of explosives by terrorists and other criminals is an increasing issue in public spaces, such as airports, railway stations, highways, sports venues, theaters, and other large buildings. Security in these environments can be achieved by different means, including the installation of scanners and other analytical devices to detect ultra-small traces of explosives in a very short time-frame to be able to take action as early as possible to prevent the detonation of such devices. Unfortunately, an ideal explosive detection system still does not exist, which means that a compromise is needed in practice. Most detection devices lack the extreme analytical sensitivity, which is nevertheless necessary due to the low vapor pressure of nearly all explosives. In addition, the rate of false positives needs to be virtually zero, which is also very difficult to achieve. Here we present an immunosensor system based on kinetic competition, which is known to be very fast and may even overcome affinity limitation, which impairs the performance of many traditional competitive assays. This immunosensor consists of a monolithic glass column with a vast excess of immobilized hapten, which traps the fluorescently labeled antibody as long as no explosive is present. In the case of the explosive 2,4,6-trinitrotoluene (TNT), some binding sites of the antibody will be blocked, which leads to an immediate breakthrough of the labeled protein, detectable by highly sensitive laser-induced fluorescence with the help of a Peltier-cooled complementary metal-oxide-semiconductor (CMOS) camera. Liquid handling is performed with high-precision syringe pumps and chip-based mixing-devices and flow-cells. The system achieved limits of detection of 1 pM (1 ppt) of the fluorescent label and around 100 pM (20 ppt) of TNT. The total assay time is less than 8 min. A cross-reactivity test with 5000 pM solutions showed no signal by pentaerythritol tetranitrate (PETN), 1,3,5-trinitroperhydro-1,3,5-triazine (RDX), and octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX). This immunosensor belongs to the most sensitive and fastest detectors for TNT with no significant cross-reactivity by non-related compounds. The consumption of the labeled antibody is surprisingly low: 1 mg of the reagent would be sufficient for more than one year of continuous biosensor operation. KW - Airport KW - Aviation KW - Bombs KW - Terrorism KW - Biosensing KW - Continuous Sensor KW - High-Speed KW - Ultrasensitive PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-511245 DO - https://doi.org/10.3390/bios10080089 VL - 10 IS - 8 SP - 89 PB - MDPI CY - Basel AN - OPUS4-51124 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Cakir, Cafer Tufan A1 - Bogoclu, Can A1 - Emmerling, Franziska A1 - Streli, Christina A1 - de Oliveira Guilherme Buzanich, Ana A1 - Radtke, Martin T1 - Machine learning for efficient grazing-exit x-ray absorption near edge structure spectroscopy analysis: Bayesian optimization approach N2 - In materials science, traditional techniques for analyzing layered structures are essential for obtaining information about local structure, electronic properties and chemical states. While valuable, these methods often require high vacuum environments and have limited depth profiling capabilities. The grazing exit x-ray absorption near-edge structure (GE-XANES) technique addresses these limitations by providing depth-resolved insight at ambient conditions, facilitating in situ material analysis without special sample preparation. However, GE-XANES is limited by long data acquisition times, which hinders its practicality for various applications. To overcome this, we have incorporated Bayesian optimization (BO) into the GE-XANES data acquisition process. This innovative approach potentially reduces measurement time by a factor of 50. We have used a standard GE-XANES experiment, which serve as reference, to validate the effectiveness and accuracy of the BO-informed experimental setup. Our results show that this optimized approach maintains data quality while significantly improving efficiency, making GE-XANES more accessible to a wider range of materials science applications. KW - Machine Learning KW - GE-XANES KW - Bayesian Optimization PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-603955 DO - https://doi.org/10.1088/2632-2153/ad4253 VL - 5 IS - 2 SP - 1 EP - 12 PB - IOP Publishing AN - OPUS4-60395 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dittmar, Stefan A1 - Ruhl, Aki S. A1 - Altmann, Korinna A1 - Jekel, Martin T1 - Settling Velocities of Small Microplastic Fragments and Fibers N2 - There is only sparse empirical data on the settling velocity of small, non-buoyant microplastics thus far, although it is an important parameter governing their vertical transport within aquatic environments. This study reports the settling velocities of 4031 exemplary microplastic particles. Focusing on the environmentally most prevalent particle shapes, irregular microplastic fragments of four different polymer types (9–289 µm) as well as five discrete length fractions (50–600 µm) of common nylon and polyester fibers were investigated, respectively. All settling experiments were carried out in quiescent water using a specialized optical imaging setup. The method has been previously validated in order to minimize disruptive factors, e.g. thermal convection or particle interactions, and thus enable the precise measurements of the velocities of individual microplastic particles (0.003–9.094 mm/s). Based on the obtained data, ten existing models for predicting a particle’s terminal settling velocity were assessed. It is concluded that models, which were specifically deduced from empirical data on larger microplastics, fail to provide accurate predictions for small microplastics. Instead, a different approach is highlighted as a viable option for computing settling velocities across the microplastics continuum in terms of size, density and shape. KW - Microplastics KW - Microplastic fibers KW - Settling velocity KW - Sinking velocity KW - Sedimentation PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-597455 DO - https://doi.org/10.1021/acs.est.3c09602 SN - 0013-936X VL - 58 IS - 14 SP - 6359 EP - 6369 PB - American Chemical Society (ACS) AN - OPUS4-59745 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Senges, Gene A1 - de Oliveira Guilherme Buzanich, Ana A1 - Lindič, Tilen A1 - Gully, Tyler A. A1 - Winter, Marlon A1 - Radtke, Martin A1 - Röder, Bettina A1 - Steinhauer, Simon A1 - Paulus, Beate A1 - Emmerling, Franziska A1 - Riedel, Sebastian T1 - Unravelling highly oxidized nickel centers in the anodic black film formed during the Simons process by in situ X-ray absorption near edge structure spectroscopy N2 - The electrofluorination after Simons has been used for the last century to produce everyday life materials. An in situ XANES investigation of the controversially debated black film apparent in the Simons process revealed high-valent nickel centers. KW - Synchrotron KW - BAMline KW - XANES PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-608366 DO - https://doi.org/10.1039/d3sc06081k SN - 2041-6520 VL - 15 IS - 12 SP - 4504 EP - 4509 PB - Royal Society of Chemistry (RSC) AN - OPUS4-60836 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Fünning, Tabea A1 - Peczek, Anna A1 - Kroh, Aleksandra A1 - Mai, Christian A1 - Paul, Martin A1 - Thomsen, Florian A1 - Tannenberg, Robert A1 - Schumann, Christoph A1 - Weller, Michael G. A1 - Mai, Andreas A1 - Steglich, Patrick C. ED - Lieberman, Robert A. ED - Baldini, Francesco ED - Homola, Jiri T1 - Optimization of local backside released micro-ring resonators for sensing applications using silicon photonic integrated circuits in a SOI technology N2 - Photonic micro-ring resonators (MRR) are widely studied for their high sensitivity across applications like environmental monitoring, healthcare, and chemical analysis. Their evanescent field sensing requires partially unembedded waveguides compatible with CMOS processing. Our approach uses local backside etching with an additional buried oxide (BOX) etch to release waveguides while preserving the back-end of line (BEOL) structure, enabling spatial separation of the sensing area and electronics. The BOX etch critically affects sensor performance, as waveguide surface roughness can alter MRR properties and coupling. We analyzed MRR design variations, comparing wet and dry etching techniques for their effects on optical performance across rib and strip waveguides in quasi-TE and quasi-TM modes. Wafer-level measurements show that backside-released MRR achieve high extinction ratios with slightly reduced quality factors, advancing high-sensitivity photonic sensors. T2 - SPIE Optics + Optoelectronics 2025 CY - Prague, Czech Republic DA - 23.05.2025 KW - Photonic sensors KW - Micro-ring resonator (MRR) KW - Silicon on insulator (SOI) KW - CMOS KW - Local backside etching PY - 2025 SN - 978-1-5106-8851-3 DO - https://doi.org/10.1117/12.3056481 VL - 13527 SP - 1 EP - 8 PB - SPIE CY - Bellingham, WA , USA AN - OPUS4-63585 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Steglich, Patrick A1 - Paul, Martin A1 - Fünning, Tabea A1 - Schumann, Christoph A1 - Mai, Christian A1 - Tannenberg, Robert A1 - Mai, Andreas ED - Cheben, Pavel ED - Čtyroký, Jiří ED - Molina-Fernández, Iñigo T1 - Towards monolithic integration of polymer-based electro-optical devices in silicon photonic integrated circuits using a 250nm SOI technology N2 - Photonic micro-ring resonators (MRR) are widely studied for their high sensitivity across applications like environmental monitoring, healthcare, and chemical analysis. Their evanescent field sensing requires partially unembedded waveguides compatible with CMOS processing. Our approach uses local backside etching with an additional buried oxide (BOX) etch to release waveguides while preserving the back-end of line (BEOL) structure, enabling spatial separation of the sensing area and electronics. The BOX etch critically affects sensor performance, as waveguide surface roughness can alter MRR properties and coupling. We analyzed MRR design variations, comparing wet and dry etching techniques for their effects on optical performance across rib and strip waveguides in quasi-TE and quasi-TM modes. Wafer-level measurements show that backside-released MRR achieve high extinction ratios with slightly reduced quality factors, advancing high-sensitivity photonic sensors. T2 - SPIE Optics + Optoelectronics 2025 CY - Prague, Czech Republic DA - 05.06.2025 KW - Photonic sensors KW - Micro-ring resonator (MRR) KW - Silicon on insulator (SOI) KW - CMOS KW - Local backside etching (LBE) PY - 2025 DO - https://doi.org/10.1117/12.3056280 VL - 13530 SP - 1 EP - 8 PB - SPIE CY - Bellingham, WA , USA AN - OPUS4-63587 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Steglich, P. A1 - Rabus, D. G. A1 - Sada, C. A1 - Paul, Martin A1 - Weller, Michael G. A1 - Mai, C. A1 - Mai, A. T1 - Silicon Photonic Micro-Ring Resonators for Chemical and Biological Sensing: A Tutorial N2 - Silicon photonic micro-ring resonators (MRR) developed on the silicon-on-insulator (SOI) platform, owing to their high sensitivity and small footprint, show great potential for many chemical and biological sensing applications such as label-free detection in environmental monitoring, biomedical engineering, and food analysis. In this tutorial, we provide the theoretical background and give design guidelines for SOI-based MRR as well as examples of surface functionalization procedures for label-free detection of molecules. After introducing the advantages and perspectives of MRR, fundamentals of MRR are described in detail, followed by an introduction to the fabrication methods, which are based on a complementary metal-oxide semiconductor (CMOS) technology. Optimization of MRR for chemical and biological sensing is provided, with special emphasis on the optimization of waveguide geometry. At this point, the difference between chemical bulk sensing and label-free surface sensing is explained, and definitions like waveguide sensitivity, ring sensitivity, overall sensitivity as well as the limit of detection (LoD) of MRR are introduced. Further, we show and explain chemical bulk sensing of sodium chloride (NaCl) in water and provide a recipe for label-free surface sensing. KW - Lab on a chip KW - Biosensor KW - Cmos KW - Silanization KW - Surface derivatization KW - Evanescent wave PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-529360 DO - https://doi.org/10.36227/techrxiv.14909901.v1 SP - 1 EP - 18 PB - IEEE CY - Piscataway Township AN - OPUS4-52936 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Paul, Martin A1 - Tannenberg, Robert A1 - Tscheuschner, Georg A1 - Ponader, Marco A1 - Weller, Michael G. T1 - Cocaine detection by a laser-induced immunofluorometric biosensor N2 - The trafficking of illegal drugs by criminal networks at borders, harbors, or airports is an increasing issue for public health as these routes ensure the main supply of illegal drugs. The prevention of drug smuggling, including the installation of scanners and other analytical devices to detect small traces of drugs within a reasonable time frame, remains a challenge. The presented immunosensor is based on a monolithic affinity column with a large excess of immobilized hapten, which traps fluorescently labeled antibodies as long as the analyte cocaine is absent. In the presence of the drug, some binding sites of the antibody will be blocked, which leads to an immediate breakthrough of the labeled protein, detectable by highly sensitive laser-induced fluorescence with the help of a Peltier-cooled complementary metal-oxide-semiconductor (CMOS) camera. Liquid handling is performed with high-precision syringe pumps and microfluidic chip-based mixing devices and flow cells. The biosensor achieved limits of detection of 7 ppt (23 pM) of cocaine with a response time of 90 s and a total assay time below 3 min. With surface wipe sampling, the biosensor was able to detect 300 pg of cocaine. This immunosensor belongs to the most sensitive and fastest detectors for cocaine and offers near-continuous analyte measurement. KW - Online detection KW - Security KW - Monoclonal antibody KW - Microfluidic mixing KW - Microfluidics KW - Lab-on-a-chip KW - Monolithic column KW - Affinity chromatography KW - Laser-induced fluorescence KW - LIF KW - ELISA KW - Wipe test KW - Low-cost PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-534487 DO - https://doi.org/10.3390/bios11090313 VL - 11 IS - 9 SP - 1 EP - 15 PB - MDPI CY - Basel AN - OPUS4-53448 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - INPR A1 - Paul, Martin A1 - Tannenberg, Robert A1 - Tscheuschner, Georg A1 - Ponader, Marco A1 - Weller, Michael G. T1 - Cocaine detection by a laser-induced immunofluorometric biosensor N2 - The trafficking of illegal drugs by criminal networks at borders, harbors, or airports is an increasing issue in public health as these routes ensure the main supply of illegal drugs. The prevention of drug smuggling, including the installation of scanners and other analytical devices to detect ultra-small traces of drugs within a reasonable time frame, remains a challenge. The presented immunosensor is based on a monolithic affinity column with a large excess of immobilized hapten, which traps fluorescently labeled antibodies as long as the analyte cocaine is absent. In the presence of the drug, some binding sites of the antibody will be blocked, which leads to an immediate breakthrough of the labeled protein, detectable by highly sensitive laser-induced fluorescence with the help of a Peltier-cooled complementary metal-oxide-semiconductor (CMOS) camera. Liquid handling is performed with high-precision syringe pumps and microfluidic chip-based mixing devices and flow cells. The biosensor achieved limits of detection of 23 pM (7 ppt) of cocaine with a response time of 90 seconds and a total assay time below 3 minutes. With surface wipe sampling, the biosensor was able to detect 300 pg of cocaine. This immunosensor belongs to the most sensitive and fastest detectors for cocaine and offers near-continuous analyte measurement. KW - Drug search KW - Customs KW - Confiscation KW - Border surveillance KW - Narcotics KW - International drug trade KW - Drug trafficking KW - Illicit drug KW - Immunosensor KW - Antibodies KW - Detection PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-529951 DO - https://doi.org/10.20944/preprints202107.0521.v1 SN - 2310-287X N1 - Geburtsname von Ponader, Marco: Wilke, M. - Birth name of Ponader, Marco: Wilke, M. SP - 1 PB - MDPI CY - Basel AN - OPUS4-52995 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ponader, Marco A1 - Röder, Bettina A1 - Paul, Martin A1 - Weller, Michael G. T1 - Sintered glass monoliths as supports for affinity columns N2 - A novel stationary phase for affinity separations is presented. This material is based on sintered borosilicate glass readily available as semi-finished filter plates with defined porosity and surface area. The material shows fast binding kinetics and excellent long-term stability under real application conditions due to lacking macropores and high mechanical rigidity. The glass surface can be easily modified with standard organosilane chemistry to immobilize selective binders or other molecules used for biointeraction. In this paper, the manufacturing of the columns and their respective column holders by 3D printing is shown in detail. The model system protein A/IgG was chosen as an example to examine the properties of such monolithic columns under realistic application conditions. Several specifications, such as (dynamic) IgG capacity, pressure stability, long-term performance, productivity, non-specific binding, and peak shape, are presented. It could be shown that due to the very high separation speed, 250 mg antibody per hour and column can be collected, which surpasses the productivity of most standard columns of the same size. The total IgG capacity of the shown columns is around 4 mg (5.5 mg/mL), which is sufficient for most tasks in research laboratories. The cycle time of an IgG separation can be less than 1 min. Due to the glass material’s excellent pressure resistance, these columns are compatible with standard HPLC systems. This is usually not the case with standard affinity columns, limited to manual use or application in low-pressure systems. The use of a standard HPLC system also improves the ability for automation, which enables the purification of hundreds of cell supernatants in one day. The sharp peak shape of the elution leads to an enrichment effect, which might increase the concentration of IgG by a factor of 3. The final concentration of IgG can be around 7.5 mg/mL without the need for an additional nano-filtration step. The purity of the IgG was > 95% in one step and nearly 99% with a second polishing run. KW - Affinity Chromatography KW - Affinity Extraction KW - Affinity Separation KW - Protein Purification KW - Down Stream Processing KW - Antibody Purification KW - Diagnostic Antibodies KW - Therapeutic Antibodies KW - Automated Purification KW - HPLC KW - FPLC KW - IgG determination KW - Concentration step KW - Monoclonal Antibodies KW - Polyclonal Antibodies KW - Human Plasma KW - Glass Support KW - Borosilicate Glass KW - Monolith KW - Sintered Material KW - Additive Manufacturing KW - Column holder KW - Construction KW - Open Science KW - Citizen Science KW - Protein A KW - Regeneration KW - High-Speed Separations KW - Robustness PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-527581 DO - https://doi.org/10.3390/separations8050056 SN - 2297-8739 N1 - Geburtsname von Ponader, Marco: Wilke, M. - Birth name of Ponader, Marco: Wilke, M. VL - 8 IS - 5 SP - 1 EP - 16 PB - MDPI CY - Basel AN - OPUS4-52758 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - INPR A1 - Ponader, Marco A1 - Röder, Bettina A1 - Paul, Martin A1 - Weller, Michael G. T1 - Sintered glass monoliths as new supports for affinity columns N2 - A novel stationary phase for affinity separations is presented. This material is based on sintered borosilicate glass readily available as semi-finished filter plates with defined porosity and surface area. The material shows fast binding kinetics and excellent long-term stability under real application conditions due to lacking macropores and high mechanical rigidity. The glass surface can be easily modified with standard organosilane chemistry to immobilize selective binders or other molecules used for biointeraction. In this paper, the manufacturing of the columns and their respective column holders by 3D printing is shown in detail. The model system protein A/IgG was chosen as an example to examine the properties of such monolithic columns under realistic application conditions. Several specifications, such as (dynamic) IgG capacity, pressure stability, long-term performance, productivity, non-specific binding, and peak shape, are presented. It could be shown that due to the very high separation speed, 250 mg antibody per hour and column can be collected, which surpasses the productivity of most standard columns of the same size. The total IgG capacity of the shown columns is around 4 mg (5.5 mg/mL), which is sufficient for most tasks in research laboratories. The cycle time of an IgG separation can be less than 1 minute. Due to the glass material's excellent pressure resistance, these columns are compatible with standard HPLC systems. This is usually not the case with standard affinity columns, limited to manual use or application in low-pressure systems. The use of a standard HPLC system also improves the ability for automation, which enables the purification of hundreds of cell supernatants in one day. The sharp peak shape of the elution leads to an enrichment effect, which might increase the concentration of IgG by a factor of 3. The final concentration of IgG can be around 7.5 mg/mL without the need for an additional nanofiltration step. The purity of the IgG was > 95% in one step and nearly 99% with a second polishing run. KW - Affinity Chromatography KW - Glass KW - Purification KW - Antibodies KW - Solid support KW - HPLC KW - FPLC KW - Separation PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-529117 DO - https://doi.org/10.20944/preprints202103.0298.v1 SN - 2310-287X N1 - Geburtsname von Ponader, Marco: Wilke, M. - Birth name of Ponader, Marco: Wilke, M. SP - 1 EP - 17 PB - MDPI CY - Basel AN - OPUS4-52911 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kabelitz, Anke A1 - de Oliveira Guilherme Buzanich, Ana A1 - Joester, Maike A1 - Reinholz, Uwe A1 - Radtke, Martin A1 - Bienert, Ralf A1 - Schulz, K. A1 - Schmack, R. A1 - Kraehnert, R. A1 - Emmerling, Franziska T1 - Time-resolved in situ studies on the formation mechanism of iron oxide nanoparticles using combined fast-XANES and SAXS N2 - The reaction of iron chlorides with an alkaline reagent is one of the most prominent methods for the synthesis of iron oxide nanoparticles. We studied the particle formation mechanism using triethanolamine as reactant and stabilizing agent. In situ fast-X-ray absorption near edge spectroscopy and small-angle X-ray scattering provide information on the oxidation state and the structural information at the same time. In situ data were complemented by ex situ transmission electron microscopy, wide-angle X-ray scattering and Raman analysis of the formed nanoparticles. The formation of maghemite nanoparticles (γ-Fe2O3) from ferric and ferrous chloride was investigated. Prior to the formation of these nanoparticles, the formation and conversion of intermediate phases (akaganeite, iron(II, III) hydroxides) was observed which undergoes a morphological and structural collapse. The thus formed small magnetite nanoparticles (Fe3O4) grow further and convert to maghemite with increasing reaction time. KW - oxidation state KW - structural information KW - maghemite PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-351376 DO - https://doi.org/10.1039/C5CE01585E SN - 1466-8033 VL - 17 IS - 44 SP - 8463 EP - 8470 CY - London, UK AN - OPUS4-35137 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - de Oliveira Guilherme Buzanich, Ana A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich A1 - Emmerling, Franziska T1 - Time- & spatial-resolved X-ray absorption fine structure (XAFS) spectroscopy in a single-shot – new analytical possibilities for in situ material characterization N2 - A new concept that comprises both time- and lateral-resolved X-ray absorption fine-structure information simultaneously in a single shot is presented. This uncomplicated set-up was tested at the BAMline at BESSY-II (Berlin, Germany). The primary broadband beam was generated by a double multilayer monochromator. The transmitted beam through the sample is diffracted by a convexly bent Si (111) crystal, producing a divergent beam. This, in turn, is collected by either an energy-sensitive area detector, the so-called color X-ray camera, or by an area-sensitive detector based on a CCD camera, in θ-2θ geometry. The first tests were performed with thin metal foils and some iron oxide mixtures. A time resolution of lower than 1 s together with a spatial resolution in one dimension of at least 50 µm is achieved. KW - Time resolution KW - Single-shot XAFS PY - 2016 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-370892 DO - https://doi.org/10.1107/S1600577516003969 SN - 1600-5775 IS - 23 SP - 769 EP - 776 PB - International Union of Crystallography CY - Chester, UK AN - OPUS4-37089 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hoque, Maroof Arshadul A1 - Sommerfeld, Thomas A1 - Lisec, Jan A1 - Das, Prasenjit A1 - Prinz, Carsten A1 - Heinekamp, Christian A1 - Stolar, Tomislav A1 - Etter, Martin A1 - Rosenberger, David A1 - George, Janine A1 - Bhattacharya, Biswajit A1 - Emmerling, Franziska T1 - Mechanochemically Synthesized Covalent Organic Framework Effectively Captures PFAS Contaminants N2 - Per‐ and polyfluoroalkyl substances (PFAS) are persistent environmental contaminants that pose significant health risks, prompting urgent efforts to develop effective removal methods and adsorbers. Covalent organic frameworks (COFs) are metal‐free adsorbers with high stability and tunable porosity. A highly crystalline COF is synthesised mechanochemically using 1,3,5‐tris(4‐aminophenyl)benzene (TAPB) and 1,3,5‐triformylbenzene (TFB). The formation dynamics are monitored in real time with time‐resolved in situ synchrotron X‐ray diffraction. The TAPB‐TFB COF demonstrates good efficiency in eliminating PFAS from water. Perfluorooctanoic acid (PFOA) and perfluorooctanesulfonic acid (PFOS) are effectively extracted, and most of the adsorption occurred within the first 10 min. Additionally, X‐ray photoelectron spectroscopy, Fourier transform infrared spectroscopy, and DFT calculations are employed to elucidate the molecular interactions between PFAS and the COF framework. The rapid and efficient removal of PFAS makes TAPB‐TFB COF a promising material for water treatment applications. KW - COFs KW - Ball-milling KW - PFAS PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-648712 DO - https://doi.org/10.1002/smll.202509275 SN - 1613-6810 VL - 21 IS - 44 SP - 1 EP - 8 PB - Wiley CY - Weinheim AN - OPUS4-64871 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kulow, Anicó A1 - de Oliveira Guilherme Buzanich, Ana A1 - Reinholz, Uwe A1 - Emmerling, Franziska A1 - Hampel, S. A1 - Fittschen, U.E.A. A1 - Streli, C. A1 - Radtke, Martin T1 - Comparison of three reconstruction methods based on deconvolution, iterative algorithm and neural network for X-ray fluorescence imaging with coded apertures N2 - X-ray imaging methods are used in many fields of research, as they allow a non-destructive Investigation of the elemental content of various samples. As for every imaging method, for X-ray imaging the optics are of crucial importance. However, these optics can be very expensive and laborious to build, as the requirements on surface roughness and precision are extremely high. Angles of reflection and refraction are often in the range of a few mrad, making a compact design hard to achieve. In this work we present a possibility to simplify X-ray imaging. We have adapted the coded aperture method, a high energy radiation imaging method that has its origins in astrophysics, to full field X-ray fluorescence imaging. In coded aperture imaging, an object is projected through a known mask, the coded aperture, onto an area sensitive detector. The resulting image consists of overlapping projections of the object and a reconstruction step is necessary to obtain the information from the recorded image. We recorded fluorescence images of different samples with an energy-dispersive 2D detector (pnCCD) and investigated different reconstruction methods. With a small coded aperture with 12 holes we could significantly increase the count rate compared to measurements with a straight polycapillary optic. We show that the reconstruction of two different samples is possible with a deconvolution approach, an iterative algorithm and a neural network. These results demonstrate that X-ray fluorescence imaging with coded apertures has the potential to deliver good results without scanning and with an improved count rate, so that measurement times can be shortened compared to established methods. KW - X-ray fluorescence imaging KW - Coded apertures KW - Imaging KW - Elemental mapping KW - Image reconstruction PY - 2020 DO - https://doi.org/10.1039/d0ja00146e VL - 35 IS - 7 SP - 1423 EP - 1434 PB - Royal Society of Chemistry CY - United Kingdom AN - OPUS4-51518 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - de Oliveira Guilherme Buzanich, Ana A1 - Radtke, Martin A1 - Yusenko, Kirill A1 - Stawski, Tomasz A1 - Kulow, Anicó A1 - Cakir, Cafer Tufan A1 - Röder, Bettina A1 - Naese, Christoph A1 - Britzke, Ralf A1 - Sintschuk, Michael A1 - Emmerling, Franziska T1 - BAMline - A real-life sample materials research beamline N2 - With increasing demand and environmental concerns, researchers are exploring new materials that can perform as well or better than traditional materials while reducing environmental impact. The BAMline, a real-life sample materials research beamline, provides unique insights into materials’ electronic and chemical structure at different time and length scales. The beamline specializes in x-ray absorption spectroscopy, x-ray fluorescence spectroscopy, and tomography experiments. This enables real-time optimization of material properties and performance for various applications, such as energy transfer, energy storage, catalysis, and corrosion resistance. This paper gives an overview of the analytical methods and sample environments of the BAMline, which cover non-destructive testing experiments in materials science, chemistry, biology, medicine, and cultural heritage. We also present our own synthesis methods, processes, and equipment developed specifically for the BAMline, and we give examples of synthesized materials and their potential applications. Finally, this article discusses the future perspectives of the BAMline and its potential for further advances in sustainable materials research. KW - Extended X-ray absorption fine structure KW - Energy storage KW - Environmental impacts KW - Nondestructive testing techniques KW - X-ray fluorescence spectroscopy KW - Corrosion KW - Near edge X-ray absorption fine structure spectroscopy KW - X-ray absorption spectroscopy PY - 2023 DO - https://doi.org/10.1063/5.0157194 VL - 158 IS - 24 SP - 1 EP - 22 PB - AIP Publishing AN - OPUS4-57824 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - de Oliveira Guilherme Buzanich, Ana A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich A1 - Emmerling, Franziska ED - de Oliveira Guilherme Buzanich, Ana T1 - Time- and spatial-resolved X-ray absorption fine structure (XAFS) spectroscopy in a single-shot: new analytical possibilities for in situ material characterization N2 - A new concept that comprises both time- and lateral-resolved X-ray absorption fine-structure information simultaneously in a single shot is presented. This uncomplicated set-up was tested at the BAMline at BESSY-II (Berlin, Germany). The primary broadband beam was generated by a double multilayer monochromator. The transmitted beam through the sample is diffracted by a convexly bent Si (111) crystal, producing a divergent beam. This, in turn, is collected by either an energy-sensitive area detector, the so-called color X-ray camera, or by an area-sensitive detector based on a CCD camera, in θ-2θ geometry. The first tests were performed with thin metal foils and some iron oxide mixtures. A time resolution of lower than 1 s together with a spatial resolution in one dimension of at least 50 µm is achieved. KW - Single-shot XAFS KW - Time resolution KW - Spatial resolution KW - Divergent XAFS PY - 2016 DO - https://doi.org/10.1107/S1600577516003969 SN - 1600-5775 VL - 23 SP - 769 EP - 776 PB - International Union of Crystallography AN - OPUS4-38370 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -