TY - JOUR A1 - Tschirschwitz, Rico A1 - Krentel, Daniel A1 - Kluge, Martin A1 - Askar, Enis A1 - Habib, Abdel Karim A1 - Kohlhoff, Harald A1 - Neumann, Patrick P. A1 - Storm, Sven-Uwe A1 - Rudolph, Michael A1 - Schoppa, André A1 - Sczepaniak, Mariusz T1 - Mobile gas cylinders in fire: Consequences in case of failure N2 - Commercial, off-the shelf propane cylinders are subjected to high safety regulations. Furthermore, those cylinders are equipped with safety devices like pressure relief valves (PRV). Despite these regulations and safety measures, a failure of the container is possible if exposed to an intense fire. The result of this is severe hazard for users, rescue forces and infrastructure. Within the framework of a destructive test series, 15 identical propane cylinders, without pressure relief devices, were exposed to an intensive fire in horizontal position until failure. Each cylinder was filled with a mass of m =11 kg of liquid propane. Three different fire sources were used (wood, petrol, propane). The experiments revealed the failure of all cylinders in a time period t < 155 s. The failure lead to a fragmentation into several major parts with throwing distances of up to l =262 m. In all trials, the temperature of the cylinder wall (top, side, bottom), of the liquid phase inside and of the surrounding fire (top, side, bottom) was recorded. In addition, the inner cylinder pressure and the induced overpressure of the blast wave after the failure were recorded. Overpressures of up to p=0.27 bar were recorded close to the cylinder (l =5 m). All tests were documented by video from several positions (general view, close-up, high-speed 5000 fps). This test series creates the basis for further experimental studies in the field of alternative fuels for vehicles. The aim of this test series is to assess and analyse the consequences of the failure of gas vessels (for LPG, CNG, CGH2) in the aftermath of severe incidents. KW - Explosion KW - Gas cylinders KW - Consequences PY - 2017 UR - http://www.sciencedirect.com/science/article/pii/S037971121730098X DO - https://doi.org/10.1016/j.firesaf.2017.05.006 SN - 0379-7112 SN - 1873-7226 VL - 91 SP - 989 EP - 996 PB - Elsevier AN - OPUS4-40550 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Krentel, Daniel A1 - Tschirschwitz, Rico A1 - Kluge, Martin A1 - Askar, Enis A1 - Habib, Abdel Karim A1 - Kohlhoff, Harald A1 - Mair, Georg W. A1 - Neumann, Patrick P. A1 - Rudolph, Michael A1 - Schoppa, André A1 - Storm, Sven-Uwe A1 - Szczepaniak, Mariusz T1 - Auswirkungen von unfallbedingtem Behälterversagen bei alternativen Pkw-Antrieben - Teil 1: Problemstellung, Stand der Technik und Voruntersuchungen N2 - Flüssige und komprimierte Gase sind in Deutschland, Europa und der Welt vielfältig als alternative Kraftstoffe im Einsatz. Diese werden unter teilweise hohem Druck in robusten Behältern an Bord gespeichert. Ein Versagen des Treibstoffbehälters im Schadensfall sollen verschiedene Sicherheitseinrichtungen, auch bei einem eventuell unfallbedingt auftretenden Fahrzeugbrand, verhindern. Sind diese Sicherheitseinrichtungen unfallbedingt beschädigt oder liegen die Belastungen dieser Einrichtung außerhalb ihres Auslegungsbereichs, ist ein Versagen des Behälters dennoch möglich. Dadurch kann es zur Bildung eines explosionsfähigen Brennstoff-Luft-Gemischs mit den entsprechenden Folgen für Fahrgäste, Einsatzkräfte und Umfeld kommen. Die Bundesanstalt für Materialforschung und -prüfung (BAM) untersucht im Forschungsprojekt "CoFi-ABV" mit umfangreichen zerstörenden Versuchsreihen im Realmaßstab die Folgen des unfallbedingten Versagens von Behältern für alternative Kraftstoffe und Maßnahmen zur Reduktion dieser Folgen im Rahmen einer ganzheitlichen Auswirkungsbetrachtung. Dieser Beitrag ist der Start einer Reihe und soll die Problemstellung sowie die Projektinhalte umfassend erläutern. KW - Alternative Antriebe KW - Alternative Kraftstoffe KW - Behälterversagen KW - Fahrzeugbrand PY - 2016 SN - 2191-0073 VL - 6 IS - 9 SP - 39 EP - 46 PB - Springer-VDI-Verlag CY - Düsseldorf AN - OPUS4-37360 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Tschirschwitz, Rico A1 - Krentel, Daniel A1 - Kluge, Martin A1 - Habib, Abdel Karim A1 - Askar, Enis A1 - Kohlhoff, Harald A1 - Neumann, Patrick P. A1 - Rudolph, Michael A1 - Schoppa, André A1 - Szczepaniak, Mariusz T1 - Versagen von Gasbehältern für alternative Treibstoffe N2 - Im Rahmen des Projekts „Complex Fires – Auswirkung von Behälterversagen“ (CoFi-ABV) sollen die Auswirkungen des Versagens von Gasbehältern für alternative Treibstoffe in Fahrzeugen unter Berücksichtigung komplexer Brand- und Explosionsszenarien untersucht werden. Es wird der aktuelle Hintergrund des Forschungsvorhabens erläutert sowie die geplanten Untersuchungen und beabsichtigten Ergebnisse vorgestellt. Hauptbestandteil des Projekts ist eine Vielzahl von zerstörenden Großversuchen. Im Vorfeld dieser Großversuche werden zur Weiterentwicklung und Adaptierung von Messtechnik Versuche im kleineren Maßstab durchgeführt. Im Folgenden werden Teile dieser Ver-suchsaufbauten im „mid-scale“ sowie die dabei verwendete Messtechnik dargestellt. Weiterhin werden erste Ergebnisse aus Wärmeeintragsversuchen zur Quantifizierung verschiedener Unterfeuerungsmethoden für die zerstörenden Großversuche vorgestellt. T2 - 14. Kolloquium zur chemischen und physikalischen Sicherheitstechnik (BAM-PTB-Kolloquium) CY - Berlin, Germany DA - 14.06.2016 KW - Explosion KW - alternative Treibstoffe KW - Behälterversagen KW - Composite PY - 2016 SN - 978-3-9817853-5-7 SN - 0938-5533 SP - 1 EP - 143 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) AN - OPUS4-37172 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Raedel, Martina A1 - Sabel, Martin A1 - Bücker, Michael A1 - Unger, Brita ED - Meeks, N. ED - Cartwright, C. ED - Meek, A. ED - Mongiatti, A. T1 - ESEM-EDX analyses for the characterisation and reproduction of nineteenth-century gold tesserae N2 - Environmental scanning electron microscopy with energy dispersive X-ray analysis (ESEM-EDX) is a versatile working tool for the examination of gold tesserae as well as for the selection of suitable materials for their reproduction. In this paper, the ESEM-EDX analyses of original gold tesserae and their damage types are presented. These analytical results form the basis for further calculations of glass properties and experiments. These calculated values enable the determination of the relevant glass properties and allow us to choose the appropriate type of modern glass for further experiments. Subsequent experiments convert this knowledge into practice. By comparing the analytical results from the original glasses and the replicas the accuracy and precision will be shown. KW - Gold mosaics KW - Tesserae KW - ESEM-EDX KW - Glass analyses KW - Damage mechanism PY - 2012 SN - 978-1-904982-65-4 SP - 107 EP - 113 PB - Archetype publications Ltd. AN - OPUS4-27641 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Neumann, Patrick P. A1 - Kohlhoff, Harald A1 - Hüllmann, Dino A1 - Kluge, Martin A1 - Askar, Enis A1 - Habib, Abdel Karim A1 - Krentel, Daniel A1 - Mair, Georg W. A1 - Rudolph, Michael A1 - Schoppa, André A1 - Szczepaniak, Mariusz A1 - Storm, Sven-Uwe A1 - Tschirschwitz, Rico T1 - Auswirkungen von Behälterversagen bei alternativen PKW-Antrieben - Teil 2: UAV-basierte Fernerkundung von Gaswolken N2 - Verkehrsunfälle unter Beteiligung von Fahrzeugen mit alternativen Kraftstoffen wie LPG („Autogas“, Liquefied Petroleum Gas), CNG (Compressed Natural Gas, komprimiertes Erdgas) oder CGH2 (Compressed Gas Hydrogen, komprimierter Wasserstoff), bergen neue, komplexe Risiken für Passagiere, Einsatzkräfte und deren Umfeld. Im Rahmen des Projektes „CoFi-ABV“ beschäftigt sich die Bundesanstalt für Materialforschung und -prüfung (BAM) unter Berücksichtigung komplexer Brand- und Explosionsszenarien mit einer ganzheitlichen Betrachtung der Auswirkungen des unfallbedingten Versagens von Gasbehältern für alternative Kraftstoffe. Ein wichtiger Teil des Forschungsvorhabens umfasst Entwicklung, Aufbau und Validierung einer unbemannten Flugplattform (Unmanned Aerial Vehicle, UAV) zur Ferndetektion von Gaswolken. Für das sogenannte gassensitive Mini-UAV wird ein robuster Open-Path-Gasdetektor auf einer Sensorbewegungsplattform in Form eines modifizierten Kamera-Gimbals, integriert. Ziel ist es, ein leistungsfähiges und robustes Werkzeug zu entwickeln, welches Einsatzkräften im Falle eines Unfalls als Hilfe zur Abschätzung der Gefahr durch Gaswolken, ihrer Ausbreitung und der notwendigen Absperrbereiche zur Verfügung steht. Dieser Artikel ist der zweite der Reihe und legt, nach Projektvorstellung im ersten Teil, nun den Schwerpunkt auf das gassensitive Mini-UAV. KW - UAV KW - Fernerkundung KW - Open-Path-Gasdetektor KW - Alternative Antriebe/Kraftstoffe KW - Behälterversagen PY - 2016 SN - 2191-0073 VL - 6 IS - 11/12 SP - 23 EP - 28 PB - Springer-VDI-Verlag CY - Düsseldorf AN - OPUS4-38517 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Krentel, Daniel A1 - Tschirschwitz, Rico A1 - Kluge, Martin A1 - Askar, Enis A1 - Habib, Abdel Karim A1 - Kohlhoff, Harald A1 - Neumann, Patrick P. A1 - Rudolph, Michael A1 - Schoppa, André A1 - Storm, Sven-Uwe A1 - Szczepaniak, Mariusz T1 - Experimental investigation of failure of LPG gas tanks in passenger cars during full fire development N2 - In continuation of a preceding test series involving sole LPG vehicle tanks, three passenger cars equipped with identical toroidal steel LPG tanks were set on fire. The tanks were installed in the space normally reserved for the spare tyre, in the car boot. No safety device was installed on the tank, in order to force critical failure of the cylinder. Two of the cars were equipped with a tank filled with liquefied propane to a level of 20 % (5.3 kg), the third one was filled completely (25.5 kg). The partially filled tanks failed critically within a time period of more than 20 min after the initiation of the fire. The fully-filled tank did not rupture; the propane was released continuously through a small leak that appeared during the fire. Comprehensive equipment was used to procure measurement data, enabling an analysis of potential consequences and hazards to humans and infrastructure within the vehicle surroundings. The inner status of the tank (pressure, temperature of the liquid phase and the steel casing), the development of the fire (temperature inside and around the vehicle) and the pressure induced in the near-field in case of tank rupture were recorded. The results were analysed in detail and compared against the data gained in tests involving sole, but identical LPG tanks. T2 - FIVE 2018 CY - Boras, Sweden DA - 03.10.2018 KW - Behälterversagen KW - LPG KW - Alternative Antriebe KW - Fahrzeugbrand KW - Auswirkungsbetrachtung PY - 2018 SN - 978-91-88695-95-6 VL - 51 SP - 123 EP - 131 PB - RISE Safety CY - Boras AN - OPUS4-46310 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Krentel, Daniel A1 - Rudolph, Michael A1 - Tschirschwitz, Rico A1 - Kluge, Martin A1 - Askar, Enis A1 - Habib, Abdel Karim A1 - Kohlhoff, Harald A1 - Neumann, Patrick P. A1 - Schalau, Bernd A1 - Schoppa, André A1 - Storm, Sven-Uwe A1 - Szczepaniak, Mariusz A1 - Mair, Georg W. T1 - Infrared radiation measurement at failure of mobile gas vessels N2 - 15 identical off-the-shelf propane cylinders (m = 11 kg liquid propane) were underfired. The infrared Radiation of the Explosion, that occurred in the aftermath of the vessel failure, was recorded using four bolometers. These measurements are compared with an estimation of the Maximum intensity gained by an Analysis of the Video data, an Extended Version of the Stefan-Boltzmann law and a BLEVE model. T2 - 26th International Colloquium on the Dynamics of Explosions and Reactive Systems CY - Boston, USA DA - 30.07.2017 KW - Failure of gas vessels KW - Propane cylinder KW - Gas explosion KW - Consequences KW - Infrared radiation PY - 2017 SP - 1 EP - 6 PB - FM Global CY - Seattle, USA AN - OPUS4-41993 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bevilacqua, Tommaso A1 - Gumenyuk, Andrey A1 - Habibi, Niloufar A1 - Hartwig, Philipp A1 - Klawonn, Axel A1 - Lanser, Martin A1 - Rethmeier, Michael A1 - Scheunemann, Lisa A1 - Schröeder, Jöerg T1 - Large-scale thermo-mechanical simulation of laser beam welding using high-performance computing: A qualitative reproduction of experimental results N2 - Laser beam welding (LBW) is a non-contact joining technique that has gained significant importance in modern industrial manufacturing. One potential problem, however, is the formation of solidification cracks, which particularly affects alloys with a pronounced melting range. The aim of the present work is the development of computational methods and software tools to numerically simulate LBW. In order to obtain a sufficiently accurate solution, a large number of finite elements has to be used. Therefore, a highly parallel scalable solver framework, based on the software library PETSc, was used to solve this computationally challenging problem on a high-performance computing architecture. Finally, the experimental results and the numerical simulations are compared. They are found to be in good qualitative agreement, which confirms the validity of the numerical simulations and allows for a better interpretation of the experimentally observed strain distribution. KW - Laser beam welding KW - Termo-mechanical processes KW - Solidification cracking KW - High-performance computing KW - Domain decomposition methods PY - 2025 DO - https://doi.org/10.1016/j.rineng.2025.108827 SN - 2590-1230 SP - 1 EP - 33 PB - Elsevier B.V. AN - OPUS4-65290 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Ferrero, Fabio A1 - Kluge, Martin A1 - Hensel, Christina A1 - Kreißig, Michael A1 - Schmidtchen, Ulrich A1 - Holtappels, Kai T1 - Unterfeuerung von Acetylendruckgasbehältern T2 - 10. Fachtagung Anlagen-, Arbeits- und Umweltsicherheit CY - Köthen, Deutschland DA - 2010-11-04 KW - Sicherheit KW - Acetylen KW - Feuer KW - Wasserkühlung KW - Wärmeübertragung PY - 2010 SN - 978-3-89746-119-2 N1 - Geburtsname von Kluge, Martin: Beckmann-Kluge, M. - Birth name of Kluge, Martin: Beckmann-Kluge, M. IS - Paper N-02 SP - 1 EP - 20 CY - Frankfurt/M. AN - OPUS4-22351 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ferrero, Fabio A1 - Kluge, Martin A1 - Kreißig, Michael A1 - Hensel, Christina A1 - Schmidtchen, Ulrich A1 - Holtappels, Kai T1 - Preventing the explosion of acetylene cylinders involved in fire with help of numerical modeling N2 - The current paper describes a mathematical model, which was developed to simulate the heat transfer in acetylene cylinders during exposure to a fire. The cases of a direct engulfment of the cylinder in the flames and of exposure to a distant fire were considered. Furthermore, the model was also applied to the prediction of the heat transfer during the cooling with water of heated acetylene cylinders, in order to assess the effectiveness of this procedure as a measure to prevent the burst of the cylinder. To provide data for the definition and validation of the model a total of 13 bonfire tests with 8.9-, 10- and 50-dm³-cylinders were performed, where pressure and temperature measurements in the samples were performed. During 5 experiments the fire was extinguished before the expected cylinder burst and a cooling with water was applied. In the paper a short description of the experimental set-up and of the test results is given. Finally, a comparison with the model predictions is provided, showing reasonable agreement. KW - Acetylene cylinders KW - Fire KW - Explosion KW - Cooling KW - Numerical model PY - 2012 DO - https://doi.org/10.1016/j.jlp.2011.10.006 SN - 0950-4230 SN - 1873-3352 N1 - Geburtsname von Kluge, Martin: Beckmann-Kluge, M. - Birth name of Kluge, Martin: Beckmann-Kluge, M. VL - 25 IS - 2 SP - 364 EP - 372 PB - Butterworth CY - Guildford, Surrey AN - OPUS4-25137 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schmidt, Martin A1 - Scheid, Marc A1 - Seifert, Alexander A1 - Böhme, Thilo A1 - Wehrstedt, Klaus-Dieter A1 - Bulin, Michael T1 - Bandbreiten sicherheitstechnischer Kenngrößen brennbarer Stäube im Gemeinsamen Stoffdatenpool Bund / Länder (GSBL) N2 - Die Beurteilung des Gefahrenpotentials brennbarer Stäube erfolgt üblicherweise mit Hilfe so genannter sicherheitstechnischer Kenngrößen (STK). Häufig werden hierfür in Datenbanken bereitgestellte Werte in der Vergangenheit untersuchter Stäube herangezogen. Insbesondere aufgrund stofflicher Unterschiede der untersuchten Stäube sind erhebliche Streuungen der ermittelten STK in Datenbanken enthaltener namentlich identischer Stäube festzustellen. Die Verwendung der Daten von Einzelstäuben kann daher zu unsicheren Einschätzungen hinsichtlich des Brand- und Explosionsschutzes führen. Vorgestellt wird ein Konzept, Stäube zu praxisrelevanten Gruppen zusammenzufassen und bewertete Bandbreiten sicherheitstechnischer Kenngrößen anzugeben. Die im Rahmen eines vom Sächsischen Landesamt für Umwelt, Landwirtschaft und Geologie, Dresden geförderten Vorhabens generierten Staubgruppen und zugehörigen Bandbreiten der STK stehen in der Datenbank GSBLpublic für die freie Nutzung zur Verfügung. T2 - 11. Fachtagung Anlagen-, Arbeits- und Umweltsicherheit CY - Köthen, Germany DA - 07.11.2013 KW - Sicherheitstechnische Kenngrößen KW - Stäube KW - Staubexplosionen KW - Datenbank PY - 2013 SN - 978-3-86011-058-4 IS - P-03 SP - 1 EP - 11 AN - OPUS4-29532 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gomes, Bruna F. A1 - Prokop, Martin A1 - Bystron, Tomas A1 - Loukrakpam, Rameshwori A1 - Melke, Julia A1 - Lobo, Carlos M. S. A1 - Fink, Michael A1 - Zhu, Mengshu A1 - Voloshina, Elena A1 - Kutter, Maximilian A1 - Hoffmann, Hendrik A1 - Yusenko, Kirill V. A1 - de Oliveira Guilherme Buzanich, Ana A1 - Röder, Bettina A1 - Bouzek, Karel A1 - Paulus, Beate A1 - Roth, Christina T1 - Following Adsorbed Intermediates on a Platinum Gas Diffusion Electrode in H3PO3-Containing Electrolytes Using In Situ X-ray Absorption Spectroscopy N2 - One of the challenges of high-temperature polymer electrolyte membrane fuel cells is the poisoning of the Pt catalystwith H3PO4. H3PO4 is imbibed into the routinely used polybenzimidazole-based membranes, which facilitate Proton conductivity in the temperature range of 120−200 °C. However, when leached out of the membrane by water produced during operation, H3PO4 adsorbs on the Pt catalyst surface, blocking the active sites and hindering the oxygen reduction reaction (ORR). The reduction of H3PO4 to H3PO3, which occurs at the anode due to a combination of a low potential and the presence of gaseous H2, has been investigated as an additional important contributing factor to the observed poisoning effect. H3PO3 has an affinity toward adsorption on Pt surfaces even greater than that of H2PO4 −. In this work, we investigated the poisoning effect of both H3PO3 and H3PO4 using a half-cell setup with a gas diffusion electrode under ambient conditions. By means of in situ X-ray absorption spectroscopy, it was possible to follow the signature of different species adsorbed on the Pt nanoparticle catalyst (H, O, H2PO4 −, and H3PO3) at different potentials under ORR conditions in various electrolytes (HClO4, H3PO4, and H3PO3). It was found that H3PO3 adsorbs in a pyramidal configuration P(OH)3 through a Pt−P bond. The competition between H3PO4 and H3PO3 adsorption was studied, which should allow for a better understanding of the catalyst poisoning mechanism and thus assist in the development of strategies to mitigate this phenomenon in the future by minimizing H3PO3 generation by, for example, improved catalyst design or adapted operation conditions or changes in the electrolyte composition. KW - H3PO4 life cycle KW - XAS KW - In situ coupling KW - High-temperature fuel cells KW - H3PO3, KW - Δμ XANES PY - 2022 DO - https://doi.org/10.1021/acscatal.2c02630 SN - 2155-5435 VL - 12 IS - 18 SP - 11472 EP - 11484 PB - American Chemical Society (ACS) AN - OPUS4-64733 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - INPR A1 - Tannenberg, Robert A1 - Tscheuschner, Georg A1 - Raab, Christopher A1 - Flemig, Sabine A1 - Döring, Sarah A1 - Ponader, Marco A1 - Thurmann, Melinda A1 - Paul, Martin A1 - Weller, Michael G. T1 - Simplified Sample Preparation and Lateral Flow Immunoassay for the Detection of Plant Viruses N2 - Lateral flow immunoassays (LFA) are widely used for decentralized testing, but their application for in-field plant virus diagnostics is often limited by tedious sample preparation. Here, we present a simplified dipstick LFA for the detection and monitoring of cowpea chlorotic mottle virus (CCMV) as a model plant pathogen. The assay employes a monoclonal mouse antibody for capture and a polyclonal rabbit antibody conjugated to 80-nm gold nanoparticles for detection. Conventional sample and conjugate pads are omitted, allowing the test strips to be dipped directly into wells containing plant extract and antibody-gold conjugate. In addition, no plastic casing was necessary, which significantly reduces waste. It was shown that CCMV concentrations as low as 4 μg/L or 400 pg per sample could be reliably detected in 15 minutes. Specificity tests confirmed that other plant viruses, cowpea mosaic virus (CPMV) and tobacco mosaic virus (TMV), did not produce false positive results. Furthermore, we describe a field-compatible sampling procedure using a manual punch and a disposable syringe. This step combines sample grinding, extraction, and conjugate reconstitution within the syringe frit, enabling the analysis of punched leaf discs without laboratory equipment. When applied to CCMV-infected cowpea plants, the assay revealed systemic infection before visual symptoms became apparent. This work demonstrates that simplified LFAs combined with innovative sampling techniques can provide sensitive, specific, and rapid diagnostics for crop monitoring and support early intervention strategies in agriculture. N2 - Lateral Flow Immunoassays (LFA) werden häufig für dezentrale Tests verwendet, aber ihre Anwendung für die Diagnose von Pflanzenviren im Feld wird oft durch die mühsame Probenvorbereitung eingeschränkt. Hier stellen wir einen vereinfachten Dipstick-LFA zum Nachweis und zur Überwachung des Cowpea Chlorotic Mottle Virus (CCMV) als Modellpflanzenpathogen vor. Der Assay verwendet einen monoklonalen Maus-Antikörper zum Einfangen des Virus und einen polyklonalen Kaninchen-Antikörper, der an 80-nm-Goldnanopartikel konjugiert ist, zum Nachweis. Herkömmliche Proben- und Konjugatpads entfallen, sodass die Teststreifen direkt in Vertiefungen getaucht werden können, die Pflanzenextrakt und Antikörper-Gold-Konjugat enthalten. Darüber hinaus war keine Kunststoffhülle erforderlich, was den Abfall erheblich reduziert. Es zeigte sich, dass CCMV-Konzentrationen von nur 4 μg/L oder 400 pg pro Probe innerhalb von 15 Minuten zuverlässig nachgewiesen werden konnten. Spezifitätstests bestätigten, dass andere Pflanzenviren, das Cowpea Mosaic Virus (CPMV) und das Tobacco Mosaic Virus (TMV), keine falsch positiven Ergebnisse lieferten. Darüber hinaus beschreiben wir ein feldtaugliches Probenahmeverfahren unter Verwendung eines manuellen Stanzers und einer Einwegspritze. Dieser Schritt kombiniert das Zerkleinern der Probe, die Extraktion und die Rekonstitution des Konjugats innerhalb der Spritzenfritte und ermöglicht so die Analyse von ausgestanzten Blattscheiben ohne Laborausrüstung. Bei der Anwendung auf CCMV-infizierte Augenbohnenpflanzen zeigte der Test eine systemische Infektion, bevor visuelle Symptome sichtbar wurden. Diese Arbeit zeigt, dass vereinfachte LFAs in Kombination mit innovativen Probenahmetechniken eine sensitive, spezifische und schnelle Diagnostik für die Überwachung von Nutzpflanzen ermöglichen und frühzeitige Interventionsstrategien in der Landwirtschaft unterstützen können. KW - Vigna unguiculata KW - Cowpea KW - Sample preparation KW - Plant pathogen KW - Mobile detection KW - Crop monitoring KW - Plastic waste KW - Lateral flow immunoassay KW - Plant virus KW - Sample pad KW - Conjugate pad PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-651731 DO - https://doi.org/10.20944/preprints202512.1492.v1 SP - 1 EP - 14 PB - MDPI CY - Basle, Switzerland AN - OPUS4-65173 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Steglich, P. A1 - Rabus, D. G. A1 - Sada, C. A1 - Paul, Martin A1 - Weller, Michael G. A1 - Mai, C. A1 - Mai, A. T1 - Silicon Photonic Micro-Ring Resonators for Chemical and Biological Sensing: A Tutorial N2 - Silicon photonic micro-ring resonators (MRR) developed on the silicon-on-insulator (SOI) platform, owing to their high sensitivity and small footprint, show great potential for many chemical and biological sensing applications such as label-free detection in environmental monitoring, biomedical engineering, and food analysis. In this tutorial,we provide the theoretical background and give design guidelines for SOI-based MRR as well as examples of surface functionalization procedures for label-free detection of molecules. After introducing the advantages and perspectives of MRR, fundamentals of MRR are described in detail, followed by an introduction to the fabrication methods, which are based on a complementary metal-oxide semiconductor (CMOS) technology. Optimization of MRR for chemical and biological sensing is provided, with special emphasis on the optimization of waveguide geometry. At this point, the difference between chemical bulk sensing and label-free surface sensing is explained, and definitions like waveguide sensitivity, ring sensitivity, overall sensitivity as well as the limit of detection (LoD) of MRR are introduced. Further, we show and explain chemical bulk sensing of sodium chloride (NaCl) in water and provide a recipe for label-free surface sensing. KW - Biosensors KW - Biophotonics KW - Chemosensor KW - Biosensor KW - Microresonator KW - Nanophotonics KW - Optical sensors KW - Photonic sensors KW - Optoelectronic KW - Ring resonator KW - Silicon photonics KW - Miniaturization KW - Lab-on-a-chip KW - Lab-on-chip KW - Waveguide KW - Surface chemistry KW - Silanization KW - Glutaraldehyde KW - Affinity immobilization KW - Antibody KW - Oriented immobilization KW - Real-time measurement PY - 2022 DO - https://doi.org/10.1109/JSEN.2021.3119547 SN - 1530-437X VL - 22 IS - 11 SP - 10089 EP - 10105 PB - IEEE AN - OPUS4-55147 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Steglich, P. A1 - Bondarenko, S. A1 - Mai, C. A1 - Paul, Martin A1 - Weller, Michael G. A1 - Mai, A. T1 - CMOS-Compatible Silicon Photonic Sensor for Refractive Index Sensing Using Local Back-Side Release N2 - Silicon photonic sensors are promising candidates for lab-on-a-chip solutions with versatile applications and scalable production prospects using complementary metal-oxide semiconductor (CMOS) fabrication methods. However, the widespread use has been hindered because the sensing area adjoins optical and electrical components making packaging and sensor handling challenging. In this work, a local back-side release of the photonic sensor is employed, enabling a separation of the sensing area from the rest of the chip. This approach allows preserving the compatibility of photonic integrated circuits in the front-end of line and metal interconnects in the back-end of line. The sensor is based on a micro-ring resonator and is fabricated on wafer-level using a CMOS technology. We revealed a ring resonator sensitivity for homogeneous sensing of 106 nm/RIU. KW - Photonic biosensor KW - Lab-on-a-chip KW - Ring resonator KW - Resonance wavelength shift KW - PIC technology KW - Back-side integration PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-517139 DO - https://doi.org/10.1109/LPT.2020.3019114 VL - 32 IS - 19 SP - 1241 EP - 1244 PB - IEEE AN - OPUS4-51713 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Tannenberg, Robert A1 - Paul, Martin A1 - Röder, Bettina A1 - Gande, S. L. A1 - Sreeramulu, S. A1 - Saxena, K. A1 - Richter, C. A1 - Schwalbe, H. A1 - Swart, C. A1 - Weller, Michael G. T1 - Chemiluminescence biosensor for the determination of cardiac troponin I (cTnI) N2 - Cardiac troponin I (cTnI) is a crucial biomarker for diagnosing cardiac vascular diseases, including acute myocardial infarction (AMI). This study presents a proof-of-concept chemiluminescence-based immunosensor for rapid and accurate measurement of cTnI, with the potential for online monitoring. The immunosensor incorporates a flow cell design and a sensitive complementary metal-oxide-semiconductor (CMOS) camera for optical readout. A microfluidic setup was established to enable selective and quasi-online determination of cTnI within ten minutes. The sensor was tested with recombinant cTnI in phosphate buffer, demonstrating measurements in the concentration range of 2–25 µg/L, with a limit of detection (LoD) of 0.6 µg/L (23 pmol/L) achieved using the optimized system. The immunosensor exhibited high selectivity, as no cross-reactivity was observed with other recombinant proteins such as cTnT and cTnC at a concentration of 16 µg/L. Measurements with diluted blood plasma and serum yielded an LoD of 60 µg/L (2.4 nmol/L) and 70 µg/L (2.9 nmol/L), respectively. This biosensor offers a promising approach for the rapid and sensitive detection of cTnI, contributing to the diagnosis and management of acute myocardial infarction and other cardiac vascular diseases. N2 - Das kardiale Troponin I (cTnI) ist ein wichtiger Biomarker für die Diagnose von Herz-Kreislauf-Erkrankungen, einschließlich des akuten Myokardinfarkts (AMI). In dieser Studie wird ein auf Chemilumineszenz basierender Immunsensor für die schnelle und genaue Messung von cTnI vorgestellt, der das Potenzial für eine Online-Überwachung hat. Der Immunsensor besteht aus einer Durchflusszelle und einer empfindlichen CMOS-Kamera (Complementary Metal-Oxide-Semiconductor) zur optischen Detektion. Es wurde ein mikrofluidischer Aufbau entwickelt, der eine selektive und quasi Online-Bestimmung von cTnI innerhalb von zehn Minuten ermöglicht. Der Sensor wurde mit rekombinantem cTnI in Phosphatpuffer getestet und zeigte einen Messbereich von 2-25 µg/L, wobei mit dem optimierten System eine Nachweisgrenze (LoD) von 0,6 µg/L (23 pmol/L) erreicht wurde. Der Immunsensor zeigte eine hohe Selektivität, da keine Kreuzreaktivität mit anderen rekombinanten Proteinen wie cTnT und cTnC bei einer Konzentration von 16 µg/L beobachtet wurde. Messungen mit verdünntem Blutplasma und Serum ergaben einen LoD von 60 µg/L (2,4 nmol/L) bzw. 70 µg/L (2,9 nmol/L). Dieser Biosensor bietet einen vielversprechenden Ansatz für den schnellen und empfindlichen Nachweis von cTnI, der zur Diagnose und Behandlung des akuten Myokardinfarkts und anderer kardialer Gefäßerkrankungen beitragen kann. KW - Acute myocardial infarction KW - Heart attack KW - Emergency KW - Diagnosis KW - Cardiac troponin KW - Biomarker KW - Immunosensor KW - Biosensor KW - Chemiluminescence KW - Luminol KW - Peroxidase KW - Monoclonal antibodies KW - Flow injection immunoassay KW - Immunometric assay KW - Immunometric biosensor KW - Microfluidic system KW - Monolithic column KW - Online biosensor PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-575471 DO - https://doi.org/10.3390/bios13040455 SN - 2079-6374 VL - 13 IS - 4 SP - 1 EP - 20 PB - MDPI CY - Basel AN - OPUS4-57547 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Paul, Martin A1 - Weller, Michael G. T1 - Antibody screening by microarray technology - Direct identification of selective high-affinity clones N2 - The primary screening of hybridoma cells is a time-critical and laborious step during the development of monoclonal antibodies. Often, critical errors occur in this phase, which supports the notion that the generation of monoclonal antibodies with hybridoma technology is difficult to control and hence, a risky venture. We think that it is crucial to improve the screening process to eliminate most of the critical deficits of the conventional approach. With this new microarray-based procedure, several advances could be achieved: Selectivity for excellent binders, high-throughput, reproducible signals, avoidance of misleading avidity (multivalency) effects, and performance of simultaneous competition experiments. The latter can also be used to select clones of desired cross-reactivity properties. In this paper, a model system with two excellent clones against carbamazepine, two weak clones, and blank supernatant containing fetal bovine serum was designed to examine the effectiveness of the new system. The excellent clones could be detected largely independent of the immunoglobulin G (IgG) concentration, which is usually unknown during the clone screening since the determination and subsequent adjustment of the antibody concentration are not feasible in most cases. Furthermore, in this approach, the enrichment, isolation, and purification of IgG for characterization is not necessary. Raw cell culture supernatant can be used directly, even when fetal calf serum (FCS) or other complex media is used. In addition, an improved method for the oriented antibody-immobilization on epoxy-silanized slides is presented. Based on the results of this model system with simulated hybridoma supernatants, we conclude that this approach should be preferable to most other protocols leading to many false positives, causing expensive and lengthy elimination steps to weed out the poor clones. KW - ELISA KW - Immunoassay KW - Microarray KW - Lab-on-a-chip KW - Miniaturization KW - Aautomatisation KW - HTS KW - High-throughput KW - Screening KW - Fluorescence KW - Label KW - Hybridoma KW - Inhibition PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-503361 DO - https://doi.org/10.3390/antib9010001 SN - 2073-4468 VL - 9 IS - 1 SP - 1 EP - 16 PB - MDPI CY - Basel AN - OPUS4-50336 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Tannenberg, Robert A1 - Paul, Martin A1 - Fünning, Tabea A1 - Schuhmann, Christoph A1 - Weller, Michael G. A1 - Steglich, Patrick T1 - Multichannel real-time detection of biomarkers with highly miniaturized photonic microchips N2 - The development of novel photonic integrated microchips (PIC) is a promising approach to allow for the convenient detection of key biomarkers in complex matrices through multichannel real-time analysis in a highly compact package. This study reports the successful development and application of a backside released CMOS chip designed for the multichannel real-time detection of biomarkers. Operating at the C-band at approx. 1550 nm, the microchip features three dedicated detection sensors in addition to a reference sensor, enabling simultaneous analysis of multiple biomarkers. The compact and highly miniaturized design of this microchip, with a footprint of just 1 mm², positions it as promising candidate for point-of-care diagnostics and personalized medicine applications. This technology opens a path to transform biomarker detection across various medical fields, offering rapid, reliable, and cost-effective diagnostic solutions. In conclusion, the presented multichannel photonic microchips signify a substantial leap forward in real-time biomarker detection, providing a highly capable platform for future research and clinical applications. T2 - SPIE Optics + Optoelectronics 2025 CY - Prague, Czech Republic DA - 07.04.2025 KW - Photonic integrated circuit KW - Ring resonator KW - Real-time detection KW - Multiplexing KW - Semiconductor KW - CMOS KW - C-reactive protein KW - CRP KW - Biomarker PY - 2025 SN - 978-1-5106-8850-6 DO - https://doi.org/10.1117/12.3056453 VL - 13527 SP - 1 EP - 6 PB - SPIE CY - Prague, Czech Republic AN - OPUS4-63478 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Steglich, Patrick A1 - Paul, Martin A1 - Mai, C. A1 - Böhme, A. A1 - Bondarenko, S. A1 - Weller, Michael G. A1 - Mai, A. T1 - A monolithically integrated microfluidic channel in a silicon-based photonic-integrated-circuit technology for biochemical sensing N2 - In this work, a cost-effective optofluidic system is proposed and preliminary experimental results are presented. A microfluidic channel monolithically integrated into a photonic integrated circuit technology is used in conjunction with a cyclic olefin copolymer (COC) substrate to provide fluidic in- and output ports. We report on initial experimental results as well as on the simple and cost-effective fabrication of this optofluidic system by means of micro-milling. KW - Biosensors KW - Biophotonics KW - Optical sensors KW - Photonic sensors KW - Ring resonators KW - Silicon photonics KW - Lab-on-a-chip KW - Microfluidics KW - Chip KW - Biochip PY - 2021 DO - https://doi.org/10.1117/12.2588791 VL - 11772 SP - 1 EP - 5 PB - SPIE AN - OPUS4-53559 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Steglich, P. A1 - Mai, C. A1 - Bondarenko, S. A1 - Paul, Martin A1 - Weller, Michael G. A1 - Schrader, S. A1 - Mai, A. T1 - BioPIC - Integration of Biosensors based on Photonic Integrated Circuits by Local-Backside Etching N2 - Silicon photonic sensors are promising candidates for lab-on-a-chip solutions with versatile applications and scalable production prospects using complementary metal-oxide semiconductor (CMOS) fabrication methods. However, the widespread use has been hindered because the sensing area adjoins optical and electrical components making packaging and sensor handling challenging. In this work, a local back-side release of the photonic sensor is employed, enabling a separation of the sensing area from the rest of the chip. This approach allows preserving the compatibility of photonic integrated circuits in the front-end of line and metal interconnects in the back-end of line. T2 - ATTRACT online Conference CY - Online meeting DA - 22.09.2020 KW - Silicon Photonics KW - Photonic Sensor KW - Photonic Integrated Circuits KW - Point-Of-Care-Diagnostics KW - CMOS KW - Microfluidics KW - Lab-on-a-chip KW - Ring resonator PY - 2020 UR - https://attract-eu.com/showroom/project/integration-of-biosensors-based-on-photonic-integrated-circuits-by-local-backside-etching-biopic/ SP - 1 EP - 5 AN - OPUS4-51735 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - INPR A1 - Paul, Martin A1 - Weller, Michael G. T1 - Antibody screening by microarray technology – Direct identification of selective high-affinity clones N2 - The primary screening of hybridoma cells is a time-critical and laborious step during the development of monoclonal antibodies. Often critical errors occur in this phase, which supports the notion that the generation of monoclonal antibodies with hybridoma technology is difficult to control and hence a risky venture. We think that it is crucial to improve the screening process to eliminate most of the immanent deficits of the conventional approach. With this new microarray-based procedure, several advances could be achieved: Selectivity for excellent binders, high throughput, reproducible signals, avoidance of misleading avidity (multivalency) effects, and simultaneous performance of competition experiments. The latter can directly be used to select clones of desired cross-reactivity properties. In this paper, a model system with two excellent clones against carbamazepine, two weak clones and blank supernatant has been designed to examine the effectiveness of the new system. The excellent clones could be detected largely independent of the IgG concentration, which is unknown during the clone screening since the determination and subsequent adjustment of the antibody concentration is not possible in most cases. Furthermore, in this approach, the enrichment, isolation, and purification of IgG for characterization is not necessary. Raw cell culture supernatant can be used directly, even when fetal calf serum (FCS) or other complex media had been used. In addition, an improved method for the oriented antibody-immobilization on epoxy-silanized slides is presented. Based on the results of this model system, we conclude that this approach should be preferable to most other protocols leading to many of false positives, causing expensive and lengthy confirmation steps to weed out the poor clones. KW - Hybridoma KW - Monoclonal Antibodies KW - Clones KW - Competitive Immunoassay KW - Hapten Immunoassay KW - False Positives PY - 2019 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-506621 DO - https://doi.org/10.20944/preprints201911.0023.v1 SN - 2310-287X SP - 1 EP - 17 PB - MDPI CY - Basel AN - OPUS4-50662 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Das, Prasenjit A1 - Chakraborty, Gouri A1 - Yang, Jin A1 - Roeser, Jérôme A1 - Küçükkeçeci, Hüseyin A1 - Nguyen, Anh Dung A1 - Schwarze, Michael A1 - Gabriel, Jose A1 - Penschke, Christopher A1 - Du, Shengjun A1 - Weigelt, Vincent A1 - Khalil, Islam E. A1 - Schmidt, Johannes A1 - Saalfrank, Peter A1 - Oschatz, Martin A1 - Rabeah, Jabor A1 - Schomäcker, Reinhard A1 - Emmerling, Franziska A1 - Thomas, Arne T1 - The Effect of Pore Functionality in Multicomponent Covalent Organic Frameworks on Stable Long‐Term Photocatalytic H2 Production N2 - AbstractIn nature, organic molecules play a vital role in light harvesting and photosynthesis. However, regarding artificial water splitting, the research focus is primarily on inorganic semiconductors. Although organic photocatalysts have high structural variability, they tend to exhibit lower quantum efficiencies for water splitting than their inorganic counterparts. Multicomponent reactions (MCRs) offer an attractive route to introduce different functional units into covalent organic frameworks (COFs) and enable semiconducting properties and high chemical stability, creating promising materials for long‐term photocatalytic applications, such as H2 production. Herein, five highly crystalline donor‐acceptor based, 4‐substituted quinoline‐linked MCR‐COFs are presented that are prepared via the three‐component Povarov reaction. The pore functionality is varied by applying different vinyl derivatives (e.g., styrene, 2‐vinyl pyridine, 4‐vinylpyridine, 4‐vinyl imidazole, 2,3,4,5,6‐pentafluorostyrene), which has a strong influence on the obtained photocatalytic activity. Especially an imidazole‐functionalized COF displays promising photocatalytic performance due to its high surface area, crystallinity, and wettability. These properties enable it to maintain its photocatalytic activity even in a membrane support. Furthermore, such MCR‐COFs display dramatically enhanced (photo)chemical stability even after long‐term solar light irradiation and exhibit a high and steady H2 evolution for at least 15 days. KW - Sstability KW - Covalent organic frameworks KW - Pore functionality KW - Long-term H2 production KW - Multicomponent reactions PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-639787 DO - https://doi.org/10.1002/aenm.202501193 SN - 1614-6832 SP - 1 EP - 10 PB - Wiley VHC-Verlag AN - OPUS4-63978 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Paul, Martin A1 - Tscheuschner, Georg A1 - Herrmann, Stefan A1 - Weller, Michael G. T1 - Fast Detection of 2,4,6-Trinitrotoluene (TNT) at ppt Level by a Laser-Induced Immunofluorometric Biosensor N2 - The illegal use of explosives by terrorists and other criminals is an increasing issue in public spaces, such as airports, railway stations, highways, sports venues, theaters, and other large buildings. Security in these environments can be achieved by different means, including the installation of scanners and other analytical devices to detect ultra-small traces of explosives in a very short time-frame to be able to take action as early as possible to prevent the detonation of such devices. Unfortunately, an ideal explosive detection system still does not exist, which means that a compromise is needed in practice. Most detection devices lack the extreme analytical sensitivity, which is nevertheless necessary due to the low vapor pressure of nearly all explosives. In addition, the rate of false positives needs to be virtually zero, which is also very difficult to achieve. Here we present an immunosensor system based on kinetic competition, which is known to be very fast and may even overcome affinity limitation, which impairs the performance of many traditional competitive assays. This immunosensor consists of a monolithic glass column with a vast excess of immobilized hapten, which traps the fluorescently labeled antibody as long as no explosive is present. In the case of the explosive 2,4,6-trinitrotoluene (TNT), some binding sites of the antibody will be blocked, which leads to an immediate breakthrough of the labeled protein, detectable by highly sensitive laser-induced fluorescence with the help of a Peltier-cooled complementary metal-oxide-semiconductor (CMOS) camera. Liquid handling is performed with high-precision syringe pumps and chip-based mixing-devices and flow-cells. The system achieved limits of detection of 1 pM (1 ppt) of the fluorescent label and around 100 pM (20 ppt) of TNT. The total assay time is less than 8 min. A cross-reactivity test with 5000 pM solutions showed no signal by pentaerythritol tetranitrate (PETN), 1,3,5-trinitroperhydro-1,3,5-triazine (RDX), and octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX). This immunosensor belongs to the most sensitive and fastest detectors for TNT with no significant cross-reactivity by non-related compounds. The consumption of the labeled antibody is surprisingly low: 1 mg of the reagent would be sufficient for more than one year of continuous biosensor operation. KW - Airport KW - Aviation KW - Bombs KW - Terrorism KW - Biosensing KW - Continuous Sensor KW - High-Speed KW - Ultrasensitive PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-511245 DO - https://doi.org/10.3390/bios10080089 VL - 10 IS - 8 SP - 89 PB - MDPI CY - Basel AN - OPUS4-51124 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Fünning, Tabea A1 - Peczek, Anna A1 - Kroh, Aleksandra A1 - Mai, Christian A1 - Paul, Martin A1 - Thomsen, Florian A1 - Tannenberg, Robert A1 - Schumann, Christoph A1 - Weller, Michael G. A1 - Mai, Andreas A1 - Steglich, Patrick C. ED - Lieberman, Robert A. ED - Baldini, Francesco ED - Homola, Jiri T1 - Optimization of local backside released micro-ring resonators for sensing applications using silicon photonic integrated circuits in a SOI technology N2 - Photonic micro-ring resonators (MRR) are widely studied for their high sensitivity across applications like environmental monitoring, healthcare, and chemical analysis. Their evanescent field sensing requires partially unembedded waveguides compatible with CMOS processing. Our approach uses local backside etching with an additional buried oxide (BOX) etch to release waveguides while preserving the back-end of line (BEOL) structure, enabling spatial separation of the sensing area and electronics. The BOX etch critically affects sensor performance, as waveguide surface roughness can alter MRR properties and coupling. We analyzed MRR design variations, comparing wet and dry etching techniques for their effects on optical performance across rib and strip waveguides in quasi-TE and quasi-TM modes. Wafer-level measurements show that backside-released MRR achieve high extinction ratios with slightly reduced quality factors, advancing high-sensitivity photonic sensors. T2 - SPIE Optics + Optoelectronics 2025 CY - Prague, Czech Republic DA - 23.05.2025 KW - Photonic sensors KW - Micro-ring resonator (MRR) KW - Silicon on insulator (SOI) KW - CMOS KW - Local backside etching PY - 2025 SN - 978-1-5106-8851-3 DO - https://doi.org/10.1117/12.3056481 VL - 13527 SP - 1 EP - 8 PB - SPIE CY - Bellingham, WA , USA AN - OPUS4-63585 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Steglich, P. A1 - Rabus, D. G. A1 - Sada, C. A1 - Paul, Martin A1 - Weller, Michael G. A1 - Mai, C. A1 - Mai, A. T1 - Silicon Photonic Micro-Ring Resonators for Chemical and Biological Sensing: A Tutorial N2 - Silicon photonic micro-ring resonators (MRR) developed on the silicon-on-insulator (SOI) platform, owing to their high sensitivity and small footprint, show great potential for many chemical and biological sensing applications such as label-free detection in environmental monitoring, biomedical engineering, and food analysis. In this tutorial, we provide the theoretical background and give design guidelines for SOI-based MRR as well as examples of surface functionalization procedures for label-free detection of molecules. After introducing the advantages and perspectives of MRR, fundamentals of MRR are described in detail, followed by an introduction to the fabrication methods, which are based on a complementary metal-oxide semiconductor (CMOS) technology. Optimization of MRR for chemical and biological sensing is provided, with special emphasis on the optimization of waveguide geometry. At this point, the difference between chemical bulk sensing and label-free surface sensing is explained, and definitions like waveguide sensitivity, ring sensitivity, overall sensitivity as well as the limit of detection (LoD) of MRR are introduced. Further, we show and explain chemical bulk sensing of sodium chloride (NaCl) in water and provide a recipe for label-free surface sensing. KW - Lab on a chip KW - Biosensor KW - Cmos KW - Silanization KW - Surface derivatization KW - Evanescent wave PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-529360 DO - https://doi.org/10.36227/techrxiv.14909901.v1 SP - 1 EP - 18 PB - IEEE CY - Piscataway Township AN - OPUS4-52936 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Paul, Martin A1 - Tannenberg, Robert A1 - Tscheuschner, Georg A1 - Ponader, Marco A1 - Weller, Michael G. T1 - Cocaine detection by a laser-induced immunofluorometric biosensor N2 - The trafficking of illegal drugs by criminal networks at borders, harbors, or airports is an increasing issue for public health as these routes ensure the main supply of illegal drugs. The prevention of drug smuggling, including the installation of scanners and other analytical devices to detect small traces of drugs within a reasonable time frame, remains a challenge. The presented immunosensor is based on a monolithic affinity column with a large excess of immobilized hapten, which traps fluorescently labeled antibodies as long as the analyte cocaine is absent. In the presence of the drug, some binding sites of the antibody will be blocked, which leads to an immediate breakthrough of the labeled protein, detectable by highly sensitive laser-induced fluorescence with the help of a Peltier-cooled complementary metal-oxide-semiconductor (CMOS) camera. Liquid handling is performed with high-precision syringe pumps and microfluidic chip-based mixing devices and flow cells. The biosensor achieved limits of detection of 7 ppt (23 pM) of cocaine with a response time of 90 s and a total assay time below 3 min. With surface wipe sampling, the biosensor was able to detect 300 pg of cocaine. This immunosensor belongs to the most sensitive and fastest detectors for cocaine and offers near-continuous analyte measurement. KW - Online detection KW - Security KW - Monoclonal antibody KW - Microfluidic mixing KW - Microfluidics KW - Lab-on-a-chip KW - Monolithic column KW - Affinity chromatography KW - Laser-induced fluorescence KW - LIF KW - ELISA KW - Wipe test KW - Low-cost PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-534487 DO - https://doi.org/10.3390/bios11090313 VL - 11 IS - 9 SP - 1 EP - 15 PB - MDPI CY - Basel AN - OPUS4-53448 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - INPR A1 - Paul, Martin A1 - Tannenberg, Robert A1 - Tscheuschner, Georg A1 - Ponader, Marco A1 - Weller, Michael G. T1 - Cocaine detection by a laser-induced immunofluorometric biosensor N2 - The trafficking of illegal drugs by criminal networks at borders, harbors, or airports is an increasing issue in public health as these routes ensure the main supply of illegal drugs. The prevention of drug smuggling, including the installation of scanners and other analytical devices to detect ultra-small traces of drugs within a reasonable time frame, remains a challenge. The presented immunosensor is based on a monolithic affinity column with a large excess of immobilized hapten, which traps fluorescently labeled antibodies as long as the analyte cocaine is absent. In the presence of the drug, some binding sites of the antibody will be blocked, which leads to an immediate breakthrough of the labeled protein, detectable by highly sensitive laser-induced fluorescence with the help of a Peltier-cooled complementary metal-oxide-semiconductor (CMOS) camera. Liquid handling is performed with high-precision syringe pumps and microfluidic chip-based mixing devices and flow cells. The biosensor achieved limits of detection of 23 pM (7 ppt) of cocaine with a response time of 90 seconds and a total assay time below 3 minutes. With surface wipe sampling, the biosensor was able to detect 300 pg of cocaine. This immunosensor belongs to the most sensitive and fastest detectors for cocaine and offers near-continuous analyte measurement. KW - Drug search KW - Customs KW - Confiscation KW - Border surveillance KW - Narcotics KW - International drug trade KW - Drug trafficking KW - Illicit drug KW - Immunosensor KW - Antibodies KW - Detection PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-529951 DO - https://doi.org/10.20944/preprints202107.0521.v1 SN - 2310-287X N1 - Geburtsname von Ponader, Marco: Wilke, M. - Birth name of Ponader, Marco: Wilke, M. SP - 1 PB - MDPI CY - Basel AN - OPUS4-52995 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ponader, Marco A1 - Röder, Bettina A1 - Paul, Martin A1 - Weller, Michael G. T1 - Sintered glass monoliths as supports for affinity columns N2 - A novel stationary phase for affinity separations is presented. This material is based on sintered borosilicate glass readily available as semi-finished filter plates with defined porosity and surface area. The material shows fast binding kinetics and excellent long-term stability under real application conditions due to lacking macropores and high mechanical rigidity. The glass surface can be easily modified with standard organosilane chemistry to immobilize selective binders or other molecules used for biointeraction. In this paper, the manufacturing of the columns and their respective column holders by 3D printing is shown in detail. The model system protein A/IgG was chosen as an example to examine the properties of such monolithic columns under realistic application conditions. Several specifications, such as (dynamic) IgG capacity, pressure stability, long-term performance, productivity, non-specific binding, and peak shape, are presented. It could be shown that due to the very high separation speed, 250 mg antibody per hour and column can be collected, which surpasses the productivity of most standard columns of the same size. The total IgG capacity of the shown columns is around 4 mg (5.5 mg/mL), which is sufficient for most tasks in research laboratories. The cycle time of an IgG separation can be less than 1 min. Due to the glass material’s excellent pressure resistance, these columns are compatible with standard HPLC systems. This is usually not the case with standard affinity columns, limited to manual use or application in low-pressure systems. The use of a standard HPLC system also improves the ability for automation, which enables the purification of hundreds of cell supernatants in one day. The sharp peak shape of the elution leads to an enrichment effect, which might increase the concentration of IgG by a factor of 3. The final concentration of IgG can be around 7.5 mg/mL without the need for an additional nano-filtration step. The purity of the IgG was > 95% in one step and nearly 99% with a second polishing run. KW - Affinity Chromatography KW - Affinity Extraction KW - Affinity Separation KW - Protein Purification KW - Down Stream Processing KW - Antibody Purification KW - Diagnostic Antibodies KW - Therapeutic Antibodies KW - Automated Purification KW - HPLC KW - FPLC KW - IgG determination KW - Concentration step KW - Monoclonal Antibodies KW - Polyclonal Antibodies KW - Human Plasma KW - Glass Support KW - Borosilicate Glass KW - Monolith KW - Sintered Material KW - Additive Manufacturing KW - Column holder KW - Construction KW - Open Science KW - Citizen Science KW - Protein A KW - Regeneration KW - High-Speed Separations KW - Robustness PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-527581 DO - https://doi.org/10.3390/separations8050056 SN - 2297-8739 N1 - Geburtsname von Ponader, Marco: Wilke, M. - Birth name of Ponader, Marco: Wilke, M. VL - 8 IS - 5 SP - 1 EP - 16 PB - MDPI CY - Basel AN - OPUS4-52758 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - INPR A1 - Ponader, Marco A1 - Röder, Bettina A1 - Paul, Martin A1 - Weller, Michael G. T1 - Sintered glass monoliths as new supports for affinity columns N2 - A novel stationary phase for affinity separations is presented. This material is based on sintered borosilicate glass readily available as semi-finished filter plates with defined porosity and surface area. The material shows fast binding kinetics and excellent long-term stability under real application conditions due to lacking macropores and high mechanical rigidity. The glass surface can be easily modified with standard organosilane chemistry to immobilize selective binders or other molecules used for biointeraction. In this paper, the manufacturing of the columns and their respective column holders by 3D printing is shown in detail. The model system protein A/IgG was chosen as an example to examine the properties of such monolithic columns under realistic application conditions. Several specifications, such as (dynamic) IgG capacity, pressure stability, long-term performance, productivity, non-specific binding, and peak shape, are presented. It could be shown that due to the very high separation speed, 250 mg antibody per hour and column can be collected, which surpasses the productivity of most standard columns of the same size. The total IgG capacity of the shown columns is around 4 mg (5.5 mg/mL), which is sufficient for most tasks in research laboratories. The cycle time of an IgG separation can be less than 1 minute. Due to the glass material's excellent pressure resistance, these columns are compatible with standard HPLC systems. This is usually not the case with standard affinity columns, limited to manual use or application in low-pressure systems. The use of a standard HPLC system also improves the ability for automation, which enables the purification of hundreds of cell supernatants in one day. The sharp peak shape of the elution leads to an enrichment effect, which might increase the concentration of IgG by a factor of 3. The final concentration of IgG can be around 7.5 mg/mL without the need for an additional nanofiltration step. The purity of the IgG was > 95% in one step and nearly 99% with a second polishing run. KW - Affinity Chromatography KW - Glass KW - Purification KW - Antibodies KW - Solid support KW - HPLC KW - FPLC KW - Separation PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-529117 DO - https://doi.org/10.20944/preprints202103.0298.v1 SN - 2310-287X N1 - Geburtsname von Ponader, Marco: Wilke, M. - Birth name of Ponader, Marco: Wilke, M. SP - 1 EP - 17 PB - MDPI CY - Basel AN - OPUS4-52911 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - de Oliveira Guilherme Buzanich, Ana A1 - Radtke, Martin A1 - Yusenko, Kirill A1 - Stawski, Tomasz A1 - Kulow, Anicó A1 - Cakir, Cafer Tufan A1 - Röder, Bettina A1 - Naese, Christoph A1 - Britzke, Ralf A1 - Sintschuk, Michael A1 - Emmerling, Franziska T1 - BAMline - A real-life sample materials research beamline N2 - With increasing demand and environmental concerns, researchers are exploring new materials that can perform as well or better than traditional materials while reducing environmental impact. The BAMline, a real-life sample materials research beamline, provides unique insights into materials’ electronic and chemical structure at different time and length scales. The beamline specializes in x-ray absorption spectroscopy, x-ray fluorescence spectroscopy, and tomography experiments. This enables real-time optimization of material properties and performance for various applications, such as energy transfer, energy storage, catalysis, and corrosion resistance. This paper gives an overview of the analytical methods and sample environments of the BAMline, which cover non-destructive testing experiments in materials science, chemistry, biology, medicine, and cultural heritage. We also present our own synthesis methods, processes, and equipment developed specifically for the BAMline, and we give examples of synthesized materials and their potential applications. Finally, this article discusses the future perspectives of the BAMline and its potential for further advances in sustainable materials research. KW - Extended X-ray absorption fine structure KW - Energy storage KW - Environmental impacts KW - Nondestructive testing techniques KW - X-ray fluorescence spectroscopy KW - Corrosion KW - Near edge X-ray absorption fine structure spectroscopy KW - X-ray absorption spectroscopy PY - 2023 DO - https://doi.org/10.1063/5.0157194 VL - 158 IS - 24 SP - 1 EP - 22 PB - AIP Publishing AN - OPUS4-57824 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Tannenberg, Robert A1 - Tscheuschner, Georg A1 - Raab, Christopher A1 - Flemig, Sabine A1 - Döring, Sarah A1 - Ponader, Marco A1 - Thurmann, Melinda A1 - Paul, Martin A1 - Weller, Michael G. T1 - Simplified Sample Preparation and Lateral Flow Immunoassay for the Detection of Plant Viruses N2 - Lateral flow immunoassays (LFAs) are widely used for on-site testing; however, their use for the rapid detection of plant viruses in the field is often limited by inconvenient sample preparation. Here, we present a new sampling method and a simplified dipstick LFA format for the detection and monitoring of cowpea chlorotic mottle virus (CCMV) as a model plant pathogen. The assay employs a monoclonal mouse antibody for capture and a poly-clonal rabbit antibody conjugated to 80 nm gold nanoparticles for detection. Conventional sample and conjugate pads are omitted, allowing the test strips to be dipped directly into wells containing plant extract and antibody–gold conjugate. No plastic casing was required, which could lead to a reduction in waste. It was shown that CCMV concentrations as low as 3.5 µg/L or 350 pg per sample could be reliably detected in 15 min. Specificity tests confirmed that other plant viruses, cowpea mosaic virus (CPMV) and tobacco mosaic virus (TMV), did not produce false-positive results. In addition, we describe a new method for on-site sampling using a manual punch and a syringe equipped with a frit. This step combines grinding the sample, extraction, filtration, and reconstitution and mixing of the antibody-gold conjugate, enabling the analysis of punched leaf disks without laboratory equipment. When applied to CCMV-infected cowpea plants, the assay revealed systemic infection before visual symptoms became apparent. This work demonstrates that simplified LFAs combined with innovative sampling techniques can provide sensitive, specific, and rapid diagnostics for crop monitoring and support early intervention strategies in agriculture. N2 - Lateral-Flow-Immunoassays (LFAs) werden häufig für Vor-Ort-Tests eingesetzt; ihr Einsatz zum schnellen Nachweis von Pflanzenviren im Feld wird jedoch oft durch eine umständliche Probenvorbereitung eingeschränkt. Hier stellen wir eine neue Probenahmemethode und ein vereinfachtes Dipstick-LFA-Format zum Nachweis und zur Überwachung des Cowpea Chlorotic Mottle Virus (CCMV) als Modellpflanzenpathogen vor. Der Test verwendet einen monoklonalen Maus-Antikörper zur Bindung und einen polyklonalen Kaninchen-Antikörper, der an 80-nm-Goldnanopartikel konjugiert ist, zum Nachweis. Herkömmliche Proben- und Konjugatpads entfallen, sodass die Teststreifen direkt in Vertiefungen getaucht werden können, die Pflanzenextrakt und das Antikörper-Gold-Konjugat enthalten. Es ist keine Kunststoffhülle erforderlich, was zu einer Reduzierung des Abfallaufkommens führen könnte. Es zeigte sich, dass CCMV-Konzentrationen von nur 3,5 µg/L oder 350 pg pro Probe innerhalb von 15 Minuten zuverlässig nachgewiesen werden konnten. Spezifitätstests bestätigten, dass andere Pflanzenviren, das Cowpea Mosaic Virus (CPMV) und das Tobacco Mosaic Virus (TMV), keine falsch-positiven Ergebnisse lieferten. Darüber hinaus beschreiben wir eine neue Methode zur Probenahme vor Ort unter Verwendung eines manuellen Lochers und einer mit einer Fritte ausgestatteten Spritze. Dieser Schritt kombiniert das Zerkleinern der Probe, die Extraktion, die Filtration sowie die Rekonstitution und das Mischen des Antikörper-Gold-Konjugats und ermöglicht so die Analyse der ausgestanzten Blattscheiben ohne Laborausrüstung. Bei der Anwendung an mit CCMV infizierten Augenbohnenpflanzen zeigte der Assay eine systemische Infektion, bevor visuelle Symptome erkennbar wurden. Diese Arbeit zeigt, dass vereinfachte LFAs in Kombination mit innovativen Probenahmetechniken eine sensitive, spezifische und schnelle Diagnostik für die Pflanzenüberwachung bieten und Strategien zur frühzeitigen Intervention in der Landwirtschaft unterstützen können. KW - Point-of-care diagnostics KW - Dipstick immunoassay KW - Pre-symptomatic detection KW - Precision agriculture KW - Integrated pest management KW - Crop health monitoring PY - 2026 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-657039 DO - https://doi.org/10.3390/bios16020100 SN - 2079-6374 VL - 16 IS - 2 SP - 1 EP - 16 PB - MDPI AG CY - Basle, Switzerland AN - OPUS4-65703 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hoffmann, Martin A1 - Gregor, Christian A1 - Schulz, Michael A1 - Szczepaniak, Mariusz A1 - Mair, Georg W. T1 - Entwickelt und validiert - Probengeometrie zur Untersuchung von gewickelten Faserverbundproben N2 - Durch die beschriebene, auf eine Umfangsbelastung ausgelegte Probengeometrie werden Fertigung und Einsatz von Druckbehältern nachempfunden. Dafür wurden bereits bestehende Probenformen überarbeitet, um im Probenkörper eine unidirektionale Zugbelastung zu erzeugen. Da die endgültigen Eigenschaften von faserverstärktem Kunststoff erst in der Fertigung entstehen, sind gleiche Fertigungsbedingungen von Proben und Bauteilen wichtig. Die hier vorgestellte Probe verspricht dadurch eine gute Eignung für den Einsatz bei Untersuchungen zum Zeitstandsverhalten. KW - Faserverstärkte Kunststoffe (FVK) KW - Druckbehälter KW - Zeitstand KW - Zugprobe PY - 2012 SN - 1865-4819 VL - 5 SP - 44 EP - 49 PB - Springer Vieweg, Springer Fachmedien Wiesbaden GmbH CY - Wiesbaden AN - OPUS4-26893 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -