TY - CONF A1 - Feigl, Michael A1 - Nofz, Marianne A1 - Sojref, Regine A1 - Dressler, Martin A1 - Pulz, Robert A1 - Rehmer, Birgit A1 - Feldmann, Ines A1 - Sabel, Martin T1 - Aluminiumoxidschichten für den Oxidationsschutz von Hochtemperaturlegierungen N2 - Effektive Al2O3-Keramik-Schutzschichten könnten die Verwendung preiswerterer Legierungen für Hochtemperaturanwendungen ermöglichen. Die Anforderungen an diese Schichten sind eine gute Haftung, chemische Stabilität und Dichtheit gegen die Umgebungsatmosphäre. T2 - DKG-Jahrestagung/Symposium Hochleistungskeramik CY - Aachen, Germany DA - 23.03.2009 KW - Schichtherstellung KW - Schichttestung KW - Hochtemperaturanwendungen PY - 2009 AN - OPUS4-35836 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dreßler, Martin A1 - Dombrowski, Felix A1 - Simon, Ulla A1 - Börnstein, Julian A1 - Hodoroaba, Vasile-Dan A1 - Feigl, Michael A1 - Grunow, Sabrina A1 - Gildenhaar, Renate A1 - Neumann, Martin T1 - Influence of gelatine coatings on compressive strength of porous hydroxyapatite ceramics N2 - Porous ceramics prepared by the foam replication technique have a high porosity and low mechanical stability. It has been reported that coating such porous ceramics with gelatin allows for an improved compressive strength. Little details regarding the influence of important gelatin parameters such as concentration, temperature and drying conditions as well as bloom number which is a measure of the gel rigidity, on this toughening effect are available. This paper investigates the influence of these parameters on compressive strength of gelatin coated porous hydroxyapatite ceramics. It was found that concentration in the gelatin sols has a marked impact whereas sol temperature, bloom number and differing conditions during subsequent drying have only little influence on the compressive strength of the coated ceramics. KW - Films KW - Composites KW - Strength KW - Apatite KW - Biomedical application PY - 2011 DO - https://doi.org/10.1016/j.jeurceramsoc.2010.11.004 SN - 0955-2219 SN - 1873-619X VL - 31 IS - 4 SP - 523 EP - 529 PB - Elsevier Ltd. CY - Oxford AN - OPUS4-23216 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gauglitz, Günter A1 - Bodensteiner, Michael A1 - Bohleber, Pascal A1 - Clases, David A1 - Dahms, Marcel A1 - Engelhard, Carsten A1 - Haider, Markus A1 - Hayen, Heiko A1 - Herbst‐Irmer, Regine A1 - Jäger, Martin A1 - Kramell, Annemarie E. A1 - Legner, Robin A1 - Matysik, Frank‐Michael A1 - Pöthig, Alexander A1 - Rädle, Matthias A1 - Seifert, Stephan A1 - Steinhauser, Georg A1 - Wolter, Kathrin T1 - Trendbericht Analytische Chemie 2024 N2 - Mehrdimensionale Trenntechniken sowie Kopplungstechniken verbessern weiter die Auflösung in der Analytik. In der Elementanalytik beeindrucken neue Entwicklungen der Massenspektrometrie mit induktiv gekoppeltem Plasma, in der Archäometrie zerstörungsfreie In‐situ‐Analysen. Der 3‐D‐Druck treibt die elektroanalytische Forschung voran, und die Prozessanalytik setzt auf Lab‐on‐a‐Chip und vermeldet Neues bei der Raman‐Spektroskopie mit Flüssigkernlichtleitern. KW - Analytische Chemie KW - Trenntechniken KW - Elementanalytik KW - Massenspektrometrie KW - Prozessanalytik PY - 2024 DO - https://doi.org/10.1002/nadc.20244139242 SN - 1868-0054 VL - 72 IS - 4 SP - 52 EP - 64 PB - Wiley CY - Weinheim AN - OPUS4-62155 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Chan, George C.-Y. A1 - Hieftje, Gary M. A1 - Omenetto, Nicoló A1 - Axner, Ove A1 - Bengtson, Arne A1 - Bings, Nicolas H. A1 - Blades, Michael W. A1 - Bogaerts, Annemie A1 - Bolshov, Mikhail A. A1 - Broekaert, José A.C. A1 - Chan, WingTat A1 - Costa-Fernández, José M. A1 - Crouch, Stanley R. A1 - De Giacomo, Alessandro A1 - D’Ulivo, Alessandro A1 - Engelhard, Carsten A1 - Falk, Heinz A1 - Farnsworth, Paul B. A1 - Florek, Stefan A1 - Gamez, Gerardo A1 - Gornushkin, Igor B. A1 - Günther, Detlef A1 - Hahn, David W. A1 - Hang, Wei A1 - Hoffmann, Volker A1 - Jakubowski, Norbert A1 - Karanassios, Vassili A1 - Koppenaal, David W. A1 - Kenneth Marcus, R. A1 - Noll, Reinhard A1 - Olesik, John W. A1 - Palleschi, Vincenzo A1 - Panne, Ulrich A1 - Pisonero, Jorge A1 - Ray, Steven J. A1 - Resano, Martín A1 - Russo, Richard E. A1 - Scheeline, Alexander A1 - Smith, Benjamin W. A1 - Sturgeon, Ralph E. A1 - Todolí, José-Luis A1 - Tognoni, Elisabetta A1 - Vanhaecke, Frank A1 - Webb, Michael R. A1 - Winefordner, James D. A1 - Yang, Lu A1 - Yu, Jin A1 - Zhang, Zhanxia T1 - Landmark Publications in Analytical Atomic Spectrometry: Fundamentals and Instrumentation Development N2 - The almost-two-centuries history of spectrochemical analysis has generated a body of literature so vast that it has become nearly intractable for experts, much less for those wishing to enter the field. Authoritative, focused reviews help to address this problem but become so granular that the overall directions of the field are lost. This broader perspective can be provided partially by general overviews but then the thinking, experimental details, theoretical underpinnings and instrumental innovations of the original work must be sacrificed. In the present compilation, this dilemma is overcome by assembling the most impactful publications in the area of analytical atomic spectrometry. Each entry was proposed by at least one current expert in the field and supported by a narrative that justifies its inclusion. The entries were then assembled into a coherent sequence and returned to contributors for a round-robin review. KW - Analytical atomic spectrometry KW - Spectroscopy KW - Instrumental analysis PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-621588 DO - https://doi.org/10.1177/00037028241263567 SN - 1943-3530 VL - 78 SP - 1 EP - 456 PB - Sage CY - London AN - OPUS4-62158 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kluge, Martin A1 - Kreißig, Michael A1 - Liebner, Christian A1 - Spoormaker, T. T1 - Identifizierung von sicherheitstechnisch gefährlichen Bedingungen für schlagartige Kompressionsvorgänge chemisch instabiler Gase im industriellen Maßstab N2 - Tetrafluorethen wird von der Polymerindustrie seit Jahrzenten als monomeres Ausgangsmaterial sowohl für die Herstellung von Polymeren (PTFE) als auch für Kopolymere (PCTFE) eingesetzt. Aufgrund seiner Eigenschaft als chemisch instabiles Gas kann TFE auch ohne Luftsauerstoff oder einen anderen Oxydator explosionsartig zerfallen. Nach der Initiierung des Zerfalls kann dieser unter bestimmten Bedingungen aufgrund des exothermen Reaktionsverhaltens sich selbstständig in Apparaten und Rohrleitungen ausbreiten. Dies geht aufgrund der freigesetzten Reaktionsenthalpie mit einem schlagartigen Anstieg von Druck und Temperatur einher, was zu erheblichen Belastungen der Materialien bis hin zum Versagen und Bruch und möglichen Folgeschäden einschließlich Personenschäden führen kann und in der Vergangenheit bereits mehrfach geführt hat. Besonders nach Wartungsarbeiten besteht die Gefahr, dass Teilabschnitte im Rohrleitungssystem mit TFE, Stickstoff oder Luft gefüllt sind mit Drücken in einem Bereich zwischen technischem Vakuum und atmosphärischem Druck wohingegen angrenzende Rohrabschnitte oder Behälter immer noch TFE bei Betriebsdrücken bis 32 bar enthalten können. Dabei sind die Abschnitte in der Praxis häufig durch Kugelhähne voneinander getrennt, die aufgrund ihrer Öffnungscharakteristik bereits bei geringen Betätigungswinkeln eine große Querschnittsfreigabe für die Strömung im Rohr ermöglichen. Dadurch können schlagartige Kompressionsvorgänge des Gases im Niederdruckbereich ermöglicht werden, die allein aufgrund der thermodynamischen Zustandsänderung zu einer erheblichen Temperaturerhöhung führen und im schlimmsten Fall zur Initiierung der Zerfallsreaktion führen können. Es wird erstmalig ein Versuchsaufbau im Industriemaßstab, der einer explosionsartigen Zerfallsreaktion von TFE standhalten kann. Zahlreiche Sicherheitskonzepte einschließlich diverser Berstscheibenkonfigurationen als auch zeitgesteuerte Schnellschlussventile wurden eingehend untersucht und bewertet, um die optimale Versuchskonfiguration für bestmögliche Reproduzierbarkeit festzulegen. Es fand eine systematische Untersuchung der schlagartigen Kompression der Systeme Luft/Luft, TFE/Luft, TFE/TFE und TFE/N2 statt. In der Hochdrucksektion wurden Drücke bis 30 bar realisiert und im Niederdrucksektor konnten Anfangsdrücke im Bereich weniger Millibar bis hin zu Atmosphärendruck eingestellt werden. Als Hauptergebnis wurde ein „Hazard diagram" erstellt, mit dessen Hilfe die Zündwahrscheinlichkeit in Abhängigkeit vom Hochdruck und Niederdruck abgeschätzt werden kann. Gefährliche Bedingungen in Rohrleitungen können dadurch auf einfachem Weg identifiziert werden. Als Referenzsystem zur Beurteilung der maximal erreichbaren nicht reaktiven Kompressionstemperaturen wurde Luft/Luft verwendet. Die damit ermittelten Daten dienten zur Bewertung von zusätzlichen exothermen Effekten, wie sie etwa bei Vorreaktion des TFE im Falle einer Dimerisierung auftreten können. Entgegen der ursprünglichen Annahme konnten die Systeme TFE/Stickstoff und TFE/TFE im verwendeten Aufbau nicht durch Kompressionsvorgänge gezündet werden. T2 - 12. Fachtagung Anlagen-, Arbeits- und Umweltsicherheit CY - Köthen, Germany DA - 05.11.2015 KW - Tetrafluoroethen KW - Zerfall KW - Selbstentzündung KW - Adiabate Kompression PY - 2015 SN - 978-3-86011-091-1 SP - 1 EP - 10 AN - OPUS4-34852 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lüth, Peter A1 - Uhlig, S. A1 - Frost, K. A1 - Malow, Marcus A1 - Michael-Schulz, Heike A1 - Schmidt, Martin A1 - Zakel, S. T1 - CEQAT-DGHS interlaboratory tests for chemical safety: Validation of laboratory test methods by determining the measurement uncertainty and probability of incorrect classification including so-called “Shark profiles” N2 - Laboratory test results are of vital importance for correctly classifying and labelling chemicals as “hazardous” as defined in the UN Globally Harmonized System (GHS) / EC CLP Regulation or as “dangerous goods” as defined in the UN Recommendations on the Transport of Dangerous Goods. Interlaboratory tests play a decisive role in assessing the reliability of laboratory test results. Interlaboratory tests performed over the last 10 years have examined different laboratory test methods. After analysing the results of these interlaboratory tests, the following conclusions can be drawn: 1. There is a need for improvement and validation for all laboratory test methods examined. 2. To avoid any discrepancy concerning the classification and labelling of chemicals, the use of validated laboratory test methods should be state of the art, with the results accompanied by the measurement uncertainty and (if applicable) the probability of incorrect classification. This paper addresses the probability of correct/incorrect classification (for example, as dangerous goods) on the basis of the measurement deviation obtained from interlaboratory tests performed by the Centre for quality assurance for testing of dangerous goods and hazardous substances (CEQAT-DGHS) to validate laboratory test methods. This paper outlines typical results (e.g. so-called “Shark profiles” – the probability of incorrect classification as a function of the true value estimated from interlaboratory test data) as well as general conclusions and steps to be taken to guarantee that laboratory test results are fit for purpose and of high quality. T2 - 13th International Symposium on Hazards, Prevention and Mitigation of Industrial Explosions (ISHPMIE 2020) CY - Braunschweig, Germany DA - 27.07.2020 KW - Dangerous goods KW - Hazardous substances KW - Interlaboratory test KW - Test method KW - Validation KW - Quality assurance KW - Measurement uncertainty KW - Incorrect classification KW - Shark profile PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-515376 UR - https://oar.ptb.de/files/download/5f3e662f4c93901010006dbf DO - https://doi.org/10.7795/810.20200724 VL - 2020 SP - 50 EP - 61 PB - Open Access Repository der Physikalisch-Technischen Bundesanstalt (PTB-OAR) CY - Braunschweig AN - OPUS4-51537 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Diller, Johannes A1 - Siebert, Ludwig A1 - Winkler, Michael A1 - Siebert, Dorina A1 - Blankenhagen, Jakob A1 - Wenzler, David A1 - Radlbeck, Christina A1 - Mensinger, Martin T1 - An integrated approach for detecting and classifying pores and surface topology for fatigue assessment 316L manufactured by powder bed fusion of metals using a laser beam using μ$$ \mu $$CT and machine learning algorithms N2 - AbstractThis research aims to detect and analyze critical internal and surface defects in metal components manufactured by powder bed fusion of metals using a laser beam (PBF‐LB/M). The aim is to assess their impact on the fatigue behavior. Therefore, a combination of methods, including image processing of micro‐computed tomography (CT) scans, fatigue testing, and machine learning, was applied. A workflow was established to contribute to the nondestructive assessment of component quality and mechanical properties. Additionally, this study illustrates the application of machine learning to address a classification problem, specifically the categorization of pores into gas pores and lack of fusion pores. Although it was shown that internal defects exhibited a reduced impact on fatigue behavior compared with surface defects, it was noted that surface defects exert a higher influence on fatigue behavior. A machine learning algorithm was developed to predict the fatigue life using surface defect features as input parameters. KW - Fatigue KW - Machine learning KW - Micro-computed tomography KW - Powder bed fusion of metals using a laser beam KW - Quality assurance PY - 2024 DO - https://doi.org/10.1111/ffe.14375 SN - 8756-758X SP - 1 EP - 16 PB - John Wiley & Sons Ltd. AN - OPUS4-60593 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lüth, Peter A1 - Brandes, E. A1 - Frost, K. A1 - Kurth, Lutz A1 - Schmidt, Martin A1 - Michael-Schulz, Heike A1 - Uhlig, S. T1 - CEQAT-DGHS Ringversuchsprogramm der BAM in Kooperation mit QuoData und PTB N2 - Bei der Bewertung der Verlässlichkeit der im Labor gewonnenen Prüfergebnisse spielen Ringversuche eine entscheidende Rolle. Die Bundesanstalt für Materialforschung und -prüfung (BAM) unterstützt deshalb den weiteren Ausbau des Ringversuchsprogramms des im Jahr 2007 gegründeten Kompetenzzentrums zur Qualitätssicherung für Prüfungen von Gefahrgütern und Gefahrstoffen auf physikalische Gefahren (Centre for quality assurance for testing of dangerous goods and hazardous substances, CEQAT-DGHS). Bei allen bisher untersuchten Prüfmethoden besteht ein Verbesserungsbedarf. Die RV müssen daher zunächst auf die Methodenentwicklung, -verbesserung und -validierung abzielen und nicht auf Leistungstests. T2 - 14. Kolloquium zur chemischen und physikalischen Sicherheitstechnik (BAM-PTB-Kolloquium) CY - Berlin, Germany DA - 14.06.2016 KW - Gefahrgut KW - Gefahrstoff KW - Ringversuch KW - Prüfmethode KW - Validierung KW - Qualitätssicherung PY - 2016 SN - 978-3-9817853-5-7 SN - 0938-5533 SP - 143 EP - 143 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-38464 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lüth, Peter A1 - Brandes, E. A1 - Frost, K. A1 - Kurth, Lutz A1 - Schmidt, Martin A1 - Michael-Schulz, Heike A1 - Uhlig, S. T1 - CEQAT-DGHS Ringversuchsprogramm für die Chemikaliensicherheit – Methodenvalidierung N2 - Bei der Bewertung der Verlässlichkeit der im Labor gewonnenen Prüfergebnisse spielen Ringversuche eine entscheidende Rolle. Die Bundesanstalt für Materialforschung und –prüfung (BAM) unterstützt deshalb den weiteren Ausbau des Ringversuchsprogramms des im Jahr 2007 gegründeten Kompetenzzentrums zur Qualitätssicherung für Prüfungen von Gefahrgütern und Gefahrstoffen auf physikalische Gefahren (Centre for quality assurance for testing of dangerous goods and hazardous substances, CEQAT-DGHS). Bei allen bisher untersuchten Prüfmethoden besteht ein Verbesserungsbedarf. Die RV müssen daher zunächst auf die Methodenentwicklung, -verbesserung und -validierung und auf die Bestimmung der Messunsicherheit der jeweiligen Prüfmethode abzielen und nicht auf Leistungstests. T2 - 13. Fachtagung Anlagen-, Arbeits- und Umweltsicherheit CY - Köthen, Germany DA - 16.11.2017 KW - Gefahrgut KW - Gefahrstoff KW - Ringversuch KW - Prüfmethode KW - Validierung KW - Qualitätssicherung PY - 2017 SN - 978-3-96057-032-5 SP - 1 EP - 13 CY - Köthen AN - OPUS4-43299 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Guhl, Svetlana A1 - Kern, Simon A1 - Meyer, Klas A1 - Wander, Lukas A1 - Bornemann-Pfeiffer, Martin A1 - Maiwald, Michael T1 - Produzieren Sie schon oder kalibrieren Sie noch? – Online-NMR-Spektrometer als Smarte Feldgeräte N2 - Der Vortrag zeigt allgemeine Anforderungen an "smarte Feldgeräte" und deren Entwicklung in den vergangenen Jahren. Am Beispiel eines smarten Online-NMR-Sensors, der in einem EU-Projekt von der BAM entwickelt wurde, wird die Umsetzung der Anforderung aufgezeigt. Schließlich werden weitere Technologieanforderungen und Lösungsansätze vorgestellt. T2 - ProcessNet-Jahrestagung und 33. DECHEMA-Jahrestagung der Biotechnologen CY - Aachen, Germany DA - 10.09.2018 KW - Prozessanalytik KW - Prozessindustrie KW - Online-NMR-Spektroskopie KW - Datenkonzepte KW - Datenanalyse KW - CONSENS PY - 2018 UR - https://onlinelibrary.wiley.com/doi/abs/10.1002/cite.201855229 DO - https://doi.org/10.1002/cite.201855229 SN - 0009-286X N1 - Geburtsname von Bornemann-Pfeiffer, Martin: Bornemann, M. - Birth name of Bornemann-Pfeiffer, Martin: Bornemann, M. VL - 90 IS - 9 SP - 1236 EP - 1236 PB - Wiley-VCH Verlag GmbH & Co. KGaA CY - Weinheim AN - OPUS4-45901 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lüth, Peter A1 - Brandes, E. A1 - Frost, K. A1 - Kurth, Lutz A1 - Schmidt, Martin A1 - Michael-Schulz, Heike A1 - Uhlig, S. T1 - CEQAT-DGHS Ringversuchsprogramm für die Chemikaliensicherheit -Methodenvalidierung N2 - Bei der Bewertung der Verlässlichkeit der im Labor gewonnenen Prüfergebnisse spielen Ringversuche eine entscheidende Rolle. Die Bundesanstalt für Materialforschung und –prüfung (BAM) unterstützt deshalb den weiteren Ausbau des Ringversuchsprogramms des im Jahr 2007 gegründeten Kompetenzzentrums zur Qualitätssicherung für Prüfungen von Gefahrgütern und Gefahrstoffen auf physikalische Gefahren (Centre for quality assurance for testing of dangerous goods and hazardous substances, CEQAT-DGHS). Bei allen bisher untersuchten Prüfmethoden besteht ein Verbesserungsbedarf. Die RV müssen daher zunächst auf die Methodenentwicklung, -verbesserung und -validierung und auf die Bestimmung der Messunsicherheit der jeweiligen Prüfmethode abzielen und nicht auf Leistungstests. T2 - Behörden-Erfahungsaustausch CY - Berlin, Germany DA - 4. Juni 2018 KW - Prüfmethode KW - Methodenvalidierung KW - Gefahrgut KW - Gefahrstoff KW - Qualitätssicherung PY - 2018 AN - OPUS4-45297 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -