TY - CONF A1 - Ewert, Uwe A1 - Martin Tschaikner, Martin A1 - Hohendorf, Stefan A1 - Bellon, Carsten A1 - Haith, M. I. A1 - Huthwaite, P. A1 - Lowe, M. J. S. T1 - Corrosion monitoring with tangential radiography and limited view computed tomography N2 - Accurate and reliable detection of subsea Pipeline corrosion is required in order to verify the integrity of the pipeline. A laboratory trial was conducted with a representative pipe sample. The accurate measurement of the wall thickness and corrosion was performed with high energy X-rays and a digital detector array. A 7.5 MV betatron was used to penetrate a stepped pipe and a welded test pipe of 3 m length and 327 mm outer diameter, with different artificial corrosion areas in the 24 mm thick steel wall. The radiographs were taken with a 40 x 40 cm² digital detector array, which was not large enough to cover the complete pipe diameter after magnification. A C-arm based geometry was tested to evaluate the potential for automated inspection in field. The primary goal was the accurate measurement of wall thickness conforming to the standard. The same geometry was used to explore the ability of a C-arm based scanner in asymmetric mode for computed tomography (CT) measurement, taking projections covering only two thirds of the pipe diameter. The technique was optimized with the modelling Software aRTist. A full volume of the pipe was reconstructed and the CT data set was used for reverse engineering, providing a CAD file for further aRTist simulations to explore the technique for subsea inspections. T2 - 42nd Annual Review of Progress in Quantitative Nondestructive Evaluation CY - Minneapolis, Minnesota, USA DA - 26.07.2015 KW - Corrosion monitoring KW - Tangential radiography KW - Computed tomography PY - 2016 SN - 978-0-7354-1353-5 DO - https://doi.org/10.1063/1.4940574 SN - 0094-243X VL - 1706 SP - 110003-1 EP - 110003-8 PB - AIP Publishing AN - OPUS4-37555 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Strüder, L. A1 - Hartmann, R. A1 - Holl, P. A1 - Ihle, S. A1 - Huth, M. A1 - Schmidt, J. A1 - Tham, Ch. A1 - Kanngießer, B. A1 - Baumann, J. A1 - Renno, A. A1 - Grenzer, J. A1 - Radtke, Martin A1 - Abboud, A. A1 - Pietsch, U. A1 - Soltau, H. T1 - High Speed, High Resolution imaging spectrometers based on pnCCDs for XRF and XRD applications N2 - For many years pnCCDs have been well known as X-ray detectors for spectroscopic imaging in many fields of science: X-Ray Fluorescence analysis (XRF), X-ray Diffraction (XRD) with light sources in large accelerator facilities as well as with laboratory light sources or with X-rays from celestial sources in X-ray astronomy. A brief introduction in GEXRF (Grazing Emission XRF) measurements with a laboratory laser produced plasma source will be given, PIXE (Particle Induced X-ray Emission) measurements and D2XRF (Double Dispersive X-Ray Fluorescence) and Slicing experiments with pnCCDs coupled to polycapillary optics performed at the BESSY synchrotron will be shown. Energy-dispersive Laue diffraction with ultra-hard X-rays for the analysis of defects in metals will conclude the overview of spectroscopic X-ray imaging measurements in the field of structure and dynamics of matter. KW - PnCCD KW - Synchrotron KW - XRF PY - 2016 DO - https://doi.org/10.1017/S1431927616001355 VL - 22 IS - S3 SP - 100 EP - 101 AN - OPUS4-38884 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Coutinho, M.L. A1 - Miller, A. Z. A1 - Martin-Sanchez, Pedro Maria A1 - Mirao, J. A1 - Gomez-Bolea, A. A1 - Machado-Moreira, B. A1 - Cerqueira-Alves, L. A1 - Jurado, V. A1 - Saiz-Jimenez,, C. A1 - Lima, A. A1 - Phillips, A. J. L. A1 - Pina, F. A1 - Macedo, M. F. T1 - A multiproxy approach to evaluate biocidal treatments on biodeteriorated majolica glazed tiles N2 - The Fishing House located on the grounds of the Marquis of Pombal Palace, Oeiras, Portugal, was built in the 18th century. During this epoch, Portuguese gardens, such as the one surrounding the Fishing House, were commonly ornamented with glazed wall tile claddings. Currently, some of these outdoor tile panels are covered with dark colored biofilms, contributing to undesirable aesthetic changes and eventually inducing chemical and physical damage to the tile surfaces. Phylogenetic analyses revealed that the investigated biofilms are mainly composed of green algae, cyanobacteria and dematiaceous fungi. With the aim of mitigating biodeterioration, four different biocides (TiO2 nanoparticles, Biotin® T, Preventol® RI 80 and Albilex Biostat®) were applied in situ to the glazed wall tiles. Their efficacy was monitored by visual examination, epifluorescence microscopy and DNA-based analysis. Significant changes in the microbial community composition were observed 4 months after treatment with Preventol® RI 80 and Biotin® T. Although the original community was inactivated after these treatments, an early stage of re-colonization was detected 6 months after the biocide application. TiO2 nanoparticles showed promising results due to their self-cleaning effect, causing the detachment of the biofilm from the tile surface, which remained clean 6 and even 24 months after biocide application. KW - Biofilm KW - Glazed tiles KW - Fungi PY - 2016 DO - https://doi.org/10.1111/1462-2920.13380 SN - 1462-2912 SN - 1462-2920 VL - 18 IS - 12 SP - 4794 EP - 4816 PB - Society for Applied Microbiology and John Wiley & Sons Ltd AN - OPUS4-37380 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Pogány, A. A1 - Balslev-Harder, D. A1 - Braban, Ch. F. A1 - Cassidy, N. A1 - Ebert, V. A1 - Ferracci, V. A1 - Hieta, T. A1 - Leuenberger, D. A1 - Martin, N. A. A1 - Pascale, C. A1 - Peltola, J. A1 - Persijn, S. A1 - Tiebe, Carlo A1 - Twigg, M. M. A1 - Vaittinen, Olavi A1 - van Wijk, J. A1 - Wirtz, K. A1 - Niederhauser, B. T1 - A metrological approach to improve accuracy and reliability of ammonia measurements in ambient air N2 - The environmental impacts of ammonia (NH3) in ambient air have become more evident in the recent decades, leading to intensifying research in this field. A number of novel analytical techniques and monitoring instruments have been developed, and the quality and availability of reference gas mixtures used for the calibration of measuring instruments has also increased significantly. However, recent inter-comparison measurements show significant discrepancies, indicating that the majority of the newly developed devices and reference materials require further thorough validation. There is a clear need for more intensive metrological research focusing on quality assurance, intercomparability and validations. MetNH3 (Metrology for ammonia in ambient air) is a three-year project within the framework of the European Metrology Research Programme (EMRP), which aims to bring metrological traceability to ambient ammonia measurements in the 0.5–500 nmol mol−1 amount fraction range. This is addressed by working in three areas: (1) improving accuracy and stability of static and dynamic reference gas mixtures, (2) developing an optical transfer standard and (3) establishing the link between high-accuracy metrological standards and field measurements. In this article we describe the concept, aims and first results of the project. KW - Ammonia in ambient air KW - Traceability KW - Reference gas standards KW - Optical transfer standard KW - Validation and testing infrastructure PY - 2016 DO - https://doi.org/10.1088/0957-0233/27/11/115012 SN - 0957-0233 VL - 27 IS - 11 SP - 115012 EP - 115026 PB - IOP Publishing Ltd. AN - OPUS4-39130 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Becker, D. A1 - Konnertz, Nora A1 - Böhning, Martin A1 - Schmidt, J. A1 - Thomas, A. T1 - Light-switchable polymers of intrinsic microporosity N2 - The interest in (micro)porous systems is greater than ever before with microporous polymers finding application in areas such as gas storage/separation and catalysis. In contrast to the vast majority of publications on microporous polymers seeking ever higher values for surface area or uptake capacity for a particular gas, this work presents a means to render a microporous system responsive to electromagnetic stimuli. The incorporation of a diarylethene (DAE) derivative in the backbone of a polymer of intrinsic microporosity (PIM) produces a microporous system that exhibits photochromism as proven by UV–vis absorption and NMR studies. In the resulting DAE-PIM, surface area is not a fixed unalterable property but can be influenced by the external and nondestructive stimulus light in a reversible manner. Furthermore, in combination with Matrimid, free-standing membranes can be produced that display light-switchable diffusivity and permeability for carbon dioxide and oxygen. In this way, material scientists are offered the potential to employ only one system that can assume several states with different properties for each. KW - Gaspermeation KW - Diffusion KW - Polymer intrinsischer Mikroporosität KW - UV-VIS PY - 2016 DO - https://doi.org/10.1021/acs.chemmater.6b02619 SN - 0897-4756 VL - 28 IS - 23 SP - 8523 EP - 8529 PB - ACS CY - Whashington,DC AN - OPUS4-38735 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Konnertz, Nora A1 - Ding, Yi A1 - Harrison, W.J. A1 - Budd, P.M. A1 - Schönhals, Andreas A1 - Böhning, Martin T1 - Molecular mobility of the high performance membrane polymer PIM-1 as investigated by dielectric spectroscopy N2 - The increasing demand for energy efficient separation processes fosters the development of new high performance polymers as selective separation layers for membranes. PIM-1 is the archetypal representative of the class of polymers of intrinsic microporosity (PIM) which are considered most promising in this sector, especially for gas separations. Since their introduction, PIMs stimulated a vast amount of research in this field and meanwhile evolved to the state of the art in membrane technology for gas separation. The major obstacle for extending the practical membrane application is their strong tendency to physical aging. For the first time, investigations by broadband dielectric spectroscopy (BDS) addressing molecular dynamics and conductivity in PIM 1 are presented. As chain packing during film formation from the casting solution and physical aging are key factors determining the separation performance of PIMs as membrane materials, characterization of the molecular mobility in such materials as revealed by BDS will provide valuable information for further development and optimization. KW - PIM-1 KW - BDS broadband dielectric spectroscopy KW - Relaxation KW - Membrane PY - 2016 DO - https://doi.org/10.1021/acsmacrolett.6b00209 SN - 2161-1653 VL - 5 IS - 4 SP - 528 EP - 532 PB - ACS American Chemical Society CY - Washington, DC, USA AN - OPUS4-35798 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -