TY - JOUR A1 - Fittschen, U.E.A. A1 - Möckel, R. A1 - Schreiner, M. A1 - klinger, M. A1 - Radtke, Martin A1 - Meyer, B. A1 - Guhl, S. A1 - Renno, A. A1 - Godinho, J. A1 - Gloaguen, R. A1 - Gutzmer, J. T1 - Bundling analytical capacities to understand phase formation in recycling of functional materials N2 - Transitioning from combustion engine-driven transportation to e-mobility demands a paradigm shift – from a system geared to maximize energy efficiency (i.e. fuel consumption) to a system that may be constrained by the availability of high technology (critical) metals required for electrical energy storage systems and drives. In the wake of these developments efforts in securing new resources of these metals from recycling of end-of-life products are increasing steadily. Recycling of Li-Ion batteries has recently been evaluated. The results pinpoint to a critical need for understanding slag Formation and its dependence on metal components like Mn under extreme conditions. This will allow researchers to predict optimal Operation setting and to react quickly to changing market demands (which may be Li or Co at one point but may also shift to Ni or rare earth elements (REE)). The long-term goal is to control the formation of specific phases in slags allowing for a Maximum yield of elements of interest and optimal recovery in the separation processes that follows. The combination of data on the physical micro structure and local chemistry of the multi-Phase products during and after processing will help to understand and derive thermodynamic and kinetic data on its formation. In this paper we are giving an overview on the analytical challenges and approaches to provide robust data on local element concentration and species (especially Mn which is a common component of next generation Li-ion batteries cathodes), spanning the dimensions from the nanometer scale to the bulk material. The complementary interactions of X-rays and electrons make them ideal probes to collect Interface and “in-depth” information. Before- and -after studies as well as in situ structural changes and Phase (trans)formation, changes in elemental and elemental species (e.g. oxidation state) distribution may be tracked by X-ray diffraction (XRD), X-ray fluorescence microscopy and X-ray Absorption spectroscopy. The application of such advanced analytical tools will not only provide essential clues during early lab-based experiments towards the development of new recycling technologies, but may also be deployed for on-line and in-line monitoring of industrial processes. KW - Synchrotron KW - XANES KW - Slags KW - Battery PY - 2019 DO - https://doi.org/10.4028/www.scientific.net/MSF.959.183 SN - 1662-9752 VL - 959 SP - 183 EP - 190 PB - Trans Tech Publ. AN - OPUS4-48900 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Zakel, S. A1 - Schröder, Volkmar A1 - Askar, Enis A1 - Gabel, D. A1 - Hirsch, W. A1 - Kleinert, J. A1 - Krause, U. A1 - Krietsch, Arne A1 - Meistes, J. A1 - Sachtleben, A. A1 - Schmidt, Martin T1 - Sicherheitstechnische Kenngrößen des Explosionsschutzes von hybriden Stoffgemischen - Normungsfähige Bestimmungsverfahren N2 - In diesem Verbundvorhaben werden standardisierte Messverfahren für hybride Gemische erarbeitet, die der Bestimmung sicherheitstechnischer Kenngrößen des Explosionsschutzes dienen. Unter einem hybriden Gemisch wird dabei ein mehrphasiges System aus Brenngas oder brennbarem Dampf, sowie Luft und brennbarem Staub verstanden. Die Veröffentlichung der Ergebnisse erfolgt in einem Abschlussbericht und als DIN-Spezifikation (DIN SPEC). Diese DIN SPEC versetzt Prüfinstitute und Industrie in die Lage, Explosionsgefahren beim Betrieb technischer Anlagen mit hybriden Gemischen einzuschätzen und damit Prozesse sowohl sicherer als auch effizienter zu steuern. Dieses Projekt wird im Rahmen des WIPANOProgramms (Wissens- und Technologietransfer durch Patente und Normen) vom BMWi gefördert. T2 - 14. Fachtagung Anlagen-, Arbeits- und Umweltsicherheit CY - Köthen, Germany DA - 07.11.2019 KW - Explosionsschutz KW - Sicherheitstechnische Kenngrößen KW - Hybride Gemische KW - Normung PY - 2019 SN - 978-3-89746-220-5 SP - 73 CY - Frankfurt am Main AN - OPUS4-49954 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dumit, Verónica I. A1 - Furxhi, Irini A1 - Nymark, Penny A1 - Afantitis, Antreas A1 - Ammar, Ammar A1 - Amorim, Monica J. B. A1 - Antunes, Dalila A1 - Avramova, Svetlana A1 - Battistelli, Chiara L. A1 - Basei, Gianpietro A1 - Bossa, Cecilia A1 - Cimpan, Emil A1 - Cimpan, Mihaela Roxana A1 - Ciornii, Dmitri A1 - Costa, Anna A1 - Delpivo, Camilla A1 - Dusinska, Maria A1 - Fonseca, Ana Sofia A1 - Friedrichs, Steffi A1 - Hodoroaba, Vasile-Dan A1 - Hristozov, Danail A1 - Isigonis, Panagiotis A1 - Jeliazkova, Nina A1 - Kochev, Nikolay A1 - Kranjc, Eva A1 - Maier, Dieter A1 - Melagraki, Georgia A1 - Papadiamantis, Anastasios G. A1 - Puzyn, Tomasz A1 - Rauscher, Hubert A1 - Reilly, Katie A1 - Jiménez, Araceli Sánchez A1 - Scott‐Fordsmand, Janeck J. A1 - Shandilya, Neeraj A1 - Shin, Hyun Kil A1 - Tancheva, Gergana A1 - van Rijn, Jeaphianne P. M. A1 - Willighagen, Egon L. A1 - Wyrzykowska, Ewelina A1 - Bakker, Martine I. A1 - Drobne, Damjana A1 - Exner, Thomas E. A1 - Himly, Martin A1 - Lynch, Iseult T1 - Challenges and Future Directions in Assessing the Quality and Completeness of Advanced Materials Safety Data for Re‐Usability: A Position Paper From the Nanosafety Community N2 - Ensuring data quality, completeness, and interoperability is crucial for progressing safety research, Safe‐and‐Sustainable‐by‐Design approaches, and regulatory approval of nanoscale and advanced materials. While the FAIR (Findable, Accessible, Interoperable, and Re‐usable) principles aim to promote data re‐use, they do not address data quality, essential for data re‐use for advancing sustainable and safe innovation. Effective quality assurance procedures require (meta)data to conform to community‐agreed standards. Nanosafety data offer a key reference point for developing best practices in data management for advanced materials, as their large‐scale generation coincided with the emergence of dedicated data quality criteria and concepts such as FAIR data. This work highlights frameworks, methodologies, and tools that address the challenges associated with the multidisciplinary nature of nanomaterial safety data. Existing approaches to evaluating the reliability, relevance, and completeness of data are considered in light of their potential for integration into harmonized standards and adaptation to advance material requirements. The goal here is to emphasize the importance of automated tools to reduce manual labor in making (meta)data FAIR, enabling trusted data re‐use and fostering safer, more sustainable innovation of advanced materials. Awareness and prioritization of these challenges are critical for building robust data infrastructures. KW - Advanced materials KW - Safety data KW - Re-usability KW - Nanosafety KW - SSbD KW - FAIR KW - Standardisation PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-652918 DO - https://doi.org/10.1002/adsu.202500567 SN - 2366-7486 SP - 1 EP - 18 PB - Wiley-VCH CY - Weinheim AN - OPUS4-65291 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Nowak, S.H. A1 - Bjeoumikhov, A. A1 - Von Borany, J. A1 - Buchriegler, J. A1 - Munnik, F. A1 - Petric, M. A1 - Renno, A.D. A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Scharf, O. A1 - Strüder, L. A1 - Wedell, R. A1 - Ziegenrücker, R. T1 - Examples of XRF and PIXE imaging with few microns resolution using SLcam® a color X-ray camera N2 - We present results of recent development of the color X-ray camera, type SLcam®, allowing detection of X-ray images with few microns resolution. Such spectral resolution is achieved with the use of high-quality polycapillary optics combined with sub-pixel resolution. Imaging of Siemens star resolution test chart reveals that the resolution limit of SLcam® can go down to nearly 5µm. Several real sample examples of measurements carried out at the laboratory, synchrotron, and particle-induced X-ray emission beamlines are shown. This is the first time SLcam® is used as particle-induced X-ray emission detector. KW - X-ray KW - Color X-ray camera KW - CXC KW - Synchrotron radiation KW - BESSY KW - BAMline PY - 2015 DO - https://doi.org/10.1002/xrs.2590 SN - 0049-8246 VL - 44 IS - 3 SP - 135 EP - 140 PB - Wiley & Sons, Ltd. CY - Chichester AN - OPUS4-33170 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Pogány, A. A1 - Balslev-Harder, D. A1 - Braban, Ch. F. A1 - Cassidy, N. A1 - Ebert, V. A1 - Ferracci, V. A1 - Hieta, T. A1 - Leuenberger, D. A1 - Martin, N. A. A1 - Pascale, C. A1 - Peltola, J. A1 - Persijn, S. A1 - Tiebe, Carlo A1 - Twigg, M. M. A1 - Vaittinen, Olavi A1 - van Wijk, J. A1 - Wirtz, K. A1 - Niederhauser, B. T1 - A metrological approach to improve accuracy and reliability of ammonia measurements in ambient air N2 - The environmental impacts of ammonia (NH3) in ambient air have become more evident in the recent decades, leading to intensifying research in this field. A number of novel analytical techniques and monitoring instruments have been developed, and the quality and availability of reference gas mixtures used for the calibration of measuring instruments has also increased significantly. However, recent inter-comparison measurements show significant discrepancies, indicating that the majority of the newly developed devices and reference materials require further thorough validation. There is a clear need for more intensive metrological research focusing on quality assurance, intercomparability and validations. MetNH3 (Metrology for ammonia in ambient air) is a three-year project within the framework of the European Metrology Research Programme (EMRP), which aims to bring metrological traceability to ambient ammonia measurements in the 0.5–500 nmol mol−1 amount fraction range. This is addressed by working in three areas: (1) improving accuracy and stability of static and dynamic reference gas mixtures, (2) developing an optical transfer standard and (3) establishing the link between high-accuracy metrological standards and field measurements. In this article we describe the concept, aims and first results of the project. KW - Ammonia in ambient air KW - Traceability KW - Reference gas standards KW - Optical transfer standard KW - Validation and testing infrastructure PY - 2016 DO - https://doi.org/10.1088/0957-0233/27/11/115012 SN - 0957-0233 VL - 27 IS - 11 SP - 115012 EP - 115026 PB - IOP Publishing Ltd. AN - OPUS4-39130 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Nowak, S.H. A1 - Bjeoumikhov, A. A1 - Von Borany, J. A1 - Buchriegler, J. A1 - Munnik, F. A1 - Petric, M. A1 - Radtke, Martin A1 - Renno, A.D. A1 - Reinholz, Uwe A1 - Scharf, O. A1 - Wedell, R. T1 - Sub-pixel resolution with a color X-ray camera N2 - The color X-ray camera SLcam® is a full-field, single photon detector providing scanning-free, energy and spatially resolved X-ray imaging. Spatial resolution is achieved with the use of polycapillary optics guiding X-ray photons from small regions on a sample to distinct energy dispersive pixels on a charged-coupled device detector. Applying sub-pixel resolution, signals from individual capillary channels can be distinguished. Therefore, the SLcam® spatial resolution, which is normally limited to the pixel size of the charge-coupled device, can be improved to the size of individual polycapillary channels. In this work a new approach to a sub-pixel resolution algorithm comprising photon events also from the pixel centers is proposed. The details of the employed numerical method and several sub-pixel resolution examples are presented and discussed. KW - Color X-ray camera KW - Sub pixel analysis PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-334948 DO - https://doi.org/10.1039/c5ja00028a SN - 0267-9477 SN - 1364-5544 SP - 1890 EP - 1897 PB - Royal Society of Chemistry CY - London AN - OPUS4-33494 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Rauwolf, M. A1 - Turyanskaya, A. A1 - Roschger, A. A1 - Prost, J. A1 - Simon, R. A1 - Scharf, O. A1 - Radtke, Martin A1 - Schoonjans, Tom A1 - de Oliveira Guilherme Buzanich, Ana A1 - Klaushofer, K. A1 - Wobrauschek, P. A1 - Hofstaetter, J. G. A1 - Roschger, P. A1 - Streli, C. T1 - Synchrotron radiation micro X-ray fluorescence spectroscopy of thin structures in bone samples: comparison of confocal and color X-ray camera setups N2 - In the quest for finding the ideal synchrotron-radiation-induced imaging method for the investigation of trace element distributions in human bone samples, experiments were performed using both a scanning confocal synchrotron radiation micro X-ray fluorescence (SR-mXRF) (FLUO beamline at ANKA) setup and a full-field color X-ray camera (BAMline at BESSY-II) setup. As zinc is a trace element of special interest in bone, the setups were optimized for its detection. The setups were compared with respect to count rate, required measurement time and spatial resolution. It was demonstrated that the ideal method depends on the element of interest. Although for Ca (a major constituent of the bone with a low energy of 3.69 keV for its K alpha XRF line) the color X-ray camera provided a higher resolution in the plane, for Zn (a trace element in bone) only the confocal SR-µXRF setup was able to sufficiently image the distribution. KW - Synchrotron KW - BAMline KW - BESSY KW - XRF KW - X-ray Color Camera PY - 2017 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-391944 DO - https://doi.org/10.1107/S1600577516017057 SN - 1600-5775 VL - 24 SP - 307 EP - 311 PB - International Union of Crystallography AN - OPUS4-39194 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - C. Pardo Pérez, L. A1 - Arndt, A. A1 - Stojkovikj, S. A1 - Y. Ahmet, I. A1 - T. Arens,, J. A1 - Dattila, F. A1 - Wendt, R. A1 - de Oliveira Guilherme Buzanich, Ana A1 - Radtke, Martin A1 - Davies, V. A1 - Höflich, K. A1 - Köhnen, E. A1 - Tockhorn, P. A1 - Golnak, R. A1 - Xiao, J. A1 - Schuck, G. A1 - Wollgarten, M. A1 - López, N. A1 - T. Mayer, M. T1 - Determining Structure-Activity Relationships in Oxide Derived CuSn Catalysts During CO2 Electroreduction Using X-Ray Spectroscopy N2 - The development of earth-abundant catalysts for selective electrochemical CO2 conversion is a central challenge. Cu-Sn bimetallic catalysts can yield selective CO2 reduction toward either CO or formate. This study presents oxide-derived Cu-Sn catalysts tunable for either product and seeks to understand the synergetic effects between Cu and Sn causing these selectivity trends. The materials undergo significant transformations under CO2 reduction conditions, and their dynamic bulk and surface structures are revealed by correlating observations from multiple methods—X-ray absorption spectroscopy for in situ study, and quasi in situ X-ray photoelectron spectroscopy for surface sensitivity. For both types of catalysts, Cu transforms to metallic Cu0 under reaction conditions. However, the Sn speciation and content differ significantly between the catalyst types: the CO-selective catalysts exhibit a surface Sn content of 13 at. % predominantly present as oxidized Sn, while the formate-selective catalysts display an Sn content of ≈70 at. % consisting of both metallic Sn0 and Sn oxide species. Density functional theory simulations suggest that Snδ+ sites weaken CO adsorption, thereby enhancing CO selectivity, while Sn0 sites hinder H adsorption and promote formate production. This study reveals the complex dependence of catalyst structure, composition, and speciation with electrochemical bias in bimetallic Cu catalysts. KW - Electrochemical CO2 conversion KW - Cu catalysts KW - X-ray absorption spectroscopy PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-547116 DO - https://doi.org/10.1002/aenm.202103328 SN - 1614-6832 VL - 12 IS - 5 SP - 2103328 PB - Wiley-VCH GmbH AN - OPUS4-54711 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Spickermann, J. A1 - Martin, K. A1 - Räder, H.J. A1 - Müllen, K. A1 - Schlaad, H. A1 - Müller, A. H. E. A1 - Krüger, Ralph-Peter T1 - Quantitative analysis of broad molecular weight distributions obtained by MALDI-TOF mass spectrometry PY - 1996 SN - 1469-0667 SN - 1356-1049 SN - 1365-0718 IS - 2 SP - 161 EP - 165 PB - IM Publications CY - Chichester AN - OPUS4-2153 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Guilherme, A. A1 - Buzanich, Günter A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Coroado, J. A1 - Dos Santos, J.M.F. A1 - Carvalho, M.L. T1 - Synchrotron micro-XRF with compound refractive lenses (CRLs) for tracing key elements on Portuguese glazed ceramics N2 - Several glazed ceramic fragments (XVIth to XVIIIth centuries) from two production centers in Portugal (Coimbra and Lisbon) were the object of this study. The ones from Coimbra comprise two sets of samples: faiences and tiles. The ones from Lisbon are only tiles (azulejos, in Portuguese). The three main divisions of such pieces are the ceramic support (body), glaze and surface decoration. The system decoration/glaze is not easy to investigate, due to the high heterogeneity resulting from the mixing procedures and firing temperatures used. Moreover, the ability of the pigment to diffuse into the base glaze varies depending on the composition of both the pigment and the glaze in terms of fusibility. In order to raster these effects, high resolution techniques are required. In this work, synchrotron micro-X-ray fluorescence (µ-XRF) analysis was performed to monitor the profiles of the characteristic elements from the colors used and the glaze in well prepared cross-sections of the samples. Key elements are: Co for blue, Mn for purple, Cu for green, Sb for yellow, Pb for the glaze and Fe for the body. The major difference observed is that faiences have glaze thicknesses between 150 and 200 µm and tiles have glaze thicknesses between 350 and 400 µm. Furthermore, in faiences all the pigments except the yellow ones are well dispersed into the glassy matrix, while in tiles, all of them are just partially diffused throughout the glaze. However, differences between the tiles from Coimbra and Lisbon were observed. In the samples from Lisbon, a higher intake from the pigment throughout the glaze is observed. KW - Synchrotron micro-XRF KW - Compound refractive lenses (CRLs) KW - Portuguese glazed ceramics PY - 2012 DO - https://doi.org/10.1039/c2ja30030c SN - 0267-9477 SN - 1364-5544 VL - 27 IS - 6 SP - 966 EP - 974 PB - Royal Society of Chemistry CY - London AN - OPUS4-26789 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -