TY - GEN A1 - Reiche, I. A1 - Berger, Achim A1 - Bevers, H. A1 - Dupuis, G. A1 - Duval, A. A1 - Görner, Wolf A1 - Guicharnaud, H. A1 - Merchel, Silke A1 - Radtke, Martin A1 - Riederer, J. A1 - Riesemeier, Heinrich A1 - Roth, M. T1 - Spatially resolved SR-XRF analyses of complex drawings by the Holbein family and silverpoint drawings by Rembrandt KW - X-ray spectrometry KW - XRF KW - Röntgenfluoreszenzanalyse KW - RFA KW - Silverpoint drawing KW - Silberstiftzeichnung PY - 2005 UR - http://www.helmholtz-berlin.de/media/media/oea/web/pr_webseite/druckschriften/berichte/bessy/annualreport2004.pdf#page=491 SN - 0179-4159 SP - 491 EP - 493 PB - Berliner Elektronenspeicherring-Gesellschaft für Synchrotronstrahlung CY - Berlin AN - OPUS4-7380 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Armbruster, B. A1 - Eilbracht, H. A1 - Grüger, A. A1 - Radtke, Martin A1 - Riesemeier, Heinrich A1 - Reiche, I. T1 - The Vikings in Berlin: SR-XRF analyses of the Hiddensee gold jewellery PY - 2005 UR - http://www.helmholtz-berlin.de/media/media/oea/web/pr_webseite/druckschriften/infos/bessy/highlights2004.pdf#page=32 SN - 1611-6127 SP - 32 EP - 33 PB - Berliner Elektronenspeicherring-Gesellschaft für Synchrotronstrahlung CY - Berlin AN - OPUS4-7386 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Kanngießer, B. A1 - Malzer, W. A1 - Fuentes Rodriguez, A. A1 - Reiche, I. A1 - Voigt, F. A1 - Radtke, Martin T1 - 3D micro X-ray fluorescence spectroscopy - combining elemental analysis with chemical speciation PY - 2004 UR - http://www.helmholtz-berlin.de/media/media/oea/web/pr_webseite/druckschriften/berichte/bessy/annualreport2003.pdf#page=495 SN - 0179-4159 SP - 495 EP - 497 PB - Berliner Elektronenspeicherring-Gesellschaft für Synchrotronstrahlung CY - Berlin AN - OPUS4-3513 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Reiche, I. A1 - Berger, Achim A1 - Duval, A. A1 - Görner, Wolf A1 - Merchel, Silke A1 - Radtke, Martin A1 - Riederer, J. A1 - Riesemeier, Heinrich T1 - Metallstiftzeichnungen Albrecht Dürers KW - Synchrotron KW - XRF analysis KW - Drawings KW - Archaeometry KW - Röntgenfluoreszenzanalyse (RFA) KW - Zeichnungen KW - Archäometrie KW - Albrecht Dürer PY - 2004 SN - 1563-2628 VL - 5 IS - 2 SP - 30 EP - 38 PB - Foto Text Verl. CY - Stuttgart AN - OPUS4-3570 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Denker, A. A1 - Hahn, Oliver A1 - Merchel, Silke A1 - Radtke, Martin A1 - Kanngießer, B. A1 - Malzer, W. A1 - Röhrs, S. A1 - Reiche, I. A1 - Stege, H. T1 - Röntgenanalytik für Kunstwerke und Kulturgüter N2 - Naturwissenschaftler arbeiten mit Archäologen, Kunsthistorikern und Restauratoren zusammen, um Materialinformationen über Kunstwerke mit den Erkenntnissen aus Altertumsforschung, Kunstgeschichte und Denkmalpflege zu verbinden. Röntgenfluoreszenz und Röntgenemission sind die Methoden der Wahl, wenn wertvolle und fragile Objekte zerstörungsfrei zu untersuchen sind. KW - Synchrotron KW - XRF analysis KW - Drawings KW - Paintings KW - Ink KW - Art objects KW - Archaeometry KW - Röntgenfluoreszenzanalyse (RFA) KW - Zeichnungen KW - Gemälde KW - Tinten KW - Kunstobjekte KW - Archäometrie PY - 2005 SN - 1439-9598 SN - 1521-3854 VL - 53 IS - 2 SP - 118 EP - 123 PB - Wiley-VCH Verl. CY - Weinheim AN - OPUS4-6898 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Reiche, I. A1 - Berger, Achim A1 - Duval, A. A1 - Görner, Wolf A1 - Guicharnaud, H. A1 - Merchel, Silke A1 - Radtke, Martin A1 - Riederer, J. A1 - Riesemeier, Heinrich A1 - Roth, M. ED - Denker, A. ED - Adriaens, A. ED - Dowsett, M. ED - Giumlia-Mair, A. T1 - Synchrotron radiation and protons on the traces of famous artists - Non-destructive analyses of silverpoint drawings by Albrecht Dürer KW - X-ray spectrometry KW - XRF KW - Röntgenfluoreszenzanalyse KW - RFA KW - Silverpoint drawing KW - Silberstiftzeichnung PY - 2006 SN - 3-8167-7178-5 SP - 91 EP - 101 PB - Fraunhofer-IRB-Verl. CY - Stuttgart AN - OPUS4-14190 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wolff, Timo A1 - Hahn, Oliver A1 - Merchel, Silke A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Denker, A. T1 - Four non-destructive X-Ray methods analyzing corroded coins: A self-critical comparison T2 - Workshop Synchrotron Radiation in Art and Archaeology 2006 CY - Berlin, Germany DA - 2006-09-27 PY - 2006 AN - OPUS4-14229 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - von Bohlen, A. A1 - Hergenröder, R. A1 - Sternemann, C. A1 - Paulus, M. A1 - Radtke, Martin A1 - Riesemeier, Heinrich T1 - Wavelenght Dispersive Synchrotron Microprobe Used for Material Analysis N2 - Synchrotron radiation (SR) has been used in recent years as an excellent excitation source for X-ray fluorescence spectrometry. SR offers, in contrast to conventional X-ray sources, highly brilliant polychromatic, polarized radiation with which micro-domain X-ray fluorescence spectrometry becomes possible. A feasibility study of utility, conducted at BESSY (Berlin) and at DELTA (Dortmund), both synchrotron facilities of the third generation, to evaluate the use of wavelength dispersive X-ray fluorescence spectrometry in combination with synchrotron radiation is presented. First results for material analysis, obtained by combining the synchrotron radiation and a commercially available spectrometer commonly attached to a scanning electron microscope, are presented. The spectrometer, of the linear type, uses curved focusing Bragg-crystals of the Johann type which leads to a high spectral resolution up to 3 eV. Examples of micro-domain analyses are presented and compared with those obtained by synchrotron radiation induced energy dispersive X-ray fluorescence. KW - Synchrotron radiation KW - WDXRF KW - EDXRF KW - Micro analysis KW - Material analysis PY - 2005 DO - https://doi.org/10.1081/CI-200048048 SN - 1073-9149 SN - 1525-6030 VL - 33 IS - 2 SP - 137 EP - 150 PB - Dekker CY - New York, NY AN - OPUS4-14235 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Reifschneider, O. A1 - Vennemann, A. A1 - Buzanich, Günter A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich A1 - Hogeback, J A1 - Köppen, C. A1 - Großgarten, M. A1 - Sperling, M. A1 - Wiemann, M. A1 - Karst, U. T1 - Revealing Silver Nanoparticle Uptake by Macrophages Using SR-μXRF and LA-ICP-MS N2 - To better study the impact of nanoparticles on both in vitro and in vivo models, tissue distribution and cellular doses need to be described more closely. Here silver nanoparticles were visualized in alveolar macrophages by means of synchrotron radiation micro X-ray fluorescence spectroscopy (SR-μXRF) with high spatial resolution of 3 × 3 μm2. For the spatial allocation of silver signals to cells and tissue structures, additional elemental labeling was carried out by staining with eosin, which binds to protein and can be detected as bromine signal with SR-μXRF. The method was compatible with immunostaining of macrophage antigens. We found that the silver distribution obtained with SR-μXRF was largely congruent with distribution maps from a subsequent laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) of the same tissue sites. The study shows a predominant, though not exclusive uptake of silver into alveolar macrophages in the rat lung, which can be modeled by a similar uptake in cultured alveolar macrophages. Advantages and limitations of the different strategies for measuring nanoparticle uptake at the single cell level are discussed. KW - Synchrotron KW - BAMline KW - XRF KW - Nanoparticle KW - Macrophagen PY - 2020 DO - https://doi.org/10.1021/acs.chemrestox.9b00507 VL - 33 IS - 5 SP - 1250 EP - 1255 PB - American Chemical Society AN - OPUS4-50855 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Vasilescu, A. A1 - Constantinescu, B. A1 - Bugoi, R. A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Simon, R. ED - Denecke, M. ED - Walker, C. T1 - Gold provenance studies for Romanian archaeological objects using micro-SR-XRF N2 - Studies by Synchrotron Radiation-X-Ray Fluorescence (SR-XRF) for the search of the presence of trace elements like Sb, Sn, Te and Pb in archaeological metallic objects found on the territory of Romania-old coins and Bronze Age jewelry, aimed to determine the provenance of the gold used in their manufacture. The results are compared with the detailed elemental composition of alluvial or primary gold samples, obtained by the same technique. This work attempted to establish the origin of the gold used for the mint of two different types of koson coins. We found that the kosons with monogram are made of refined gold, while the one used for the kosons without monogram is mainly alluvial. The gold used in the manufacture of the Calarasi Vulchitrun-type disk and the Tauteu hair ring is also of alluvial origin. T2 - 20th International congress on X-ray optics and microanalysis CY - Karlsruhe, Germany DA - 2009-09-14 KW - Provenance KW - Gold KW - SR-XRF KW - Trace elements PY - 2010 UR - http://link.aip.org/link/?APCPCS/1221/139/1 SN - 978-0-7354-0764-0 DO - https://doi.org/10.1063/1.3399240 SN - 0094-243X SP - 139 EP - 143 PB - American Institute of Physics AN - OPUS4-21182 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Constantinescu, B. A1 - Vasilescu, A. A1 - Radtke, Martin A1 - Reinholz, Uwe T1 - A study on gold and copper provenance for Romanian prehistoric objects using micro-SR XRF N2 - This study intends to clarify the metal provenance of gold archaeological items using the variation of the Au–Ag ratio and the presence of trace elements as Sn, Sb, Te, and Pb, concentrating on gold Dacian Koson coins, recovered recently. It also extends the area of our investigations to the copper provenance of Bronze Age artifacts—axes, sickles, and celts—found on Romanian territory. The experiments were performed by micro-SR XRF at BESSY Berlin, at the BAM-line facility. Two types of coins (Koson, with and without monogram) were analysed. The conclusions we reached were that most of the monogram coins are made from refined gold (3–5% Ag, less than 0.5% Cu), while the without monogram coins are made from native Transylvanian gold (9–20% Ag, 0.5–2% Cu), of alluvial origin, proved by the presence of Sn, Sb and Te embedded in the gold. The problem of provenance for prehistoric Romanian copper and bronze objects consists in linking their elemental compositional patterns to the ones of the Bronze Age regional mines from Bulgaria, Serbia or Transylvania, most likely used as ore sources for their manufacture. The studied samples present relevant traces of As, Ag, Sb, and Co, suggesting the most probable use of copper from Serbia or northern Bulgaria for their manufacture. KW - X-ray fluorescence KW - Synchrotron radiation KW - Proton induced X-ray emission KW - Archaeometry KW - Gold PY - 2011 DO - https://doi.org/10.1039/c0ja00215a SN - 0267-9477 SN - 1364-5544 VL - 26 IS - 5 SP - 917 EP - 921 PB - Royal Society of Chemistry CY - London AN - OPUS4-23191 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Brücher, M. A1 - von Bohlen, A. A1 - Jacob, P. A1 - Franzke, J. A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Müller, Bernd R. A1 - Scharf, Oliver A1 - Hergenröder, R. T1 - The charge of solid-liquid interfaces measured by X-ray standing waves and streaming current N2 - Measurements of ion distributions at a charged solid–liquid interface using X-ray standing waves (XSW) are presented. High energy synchrotron radiation (17.48 keV) is used to produce an XSW pattern inside a thin water film on a silicon wafer. The liquid phase is an aqueous solution containing Br and Rb ions. The surface charge is adjusted by titration. Measurements are performed over a pH range from 2.2–9, using the native Si oxide layer and functional (amine) groups as surface charge. The Debye length, indicating the extension of the diffuse layer, could be measured with values varying between 1–4 nm. For functionalized wafers, the pH dependent change from attraction to repulsion of an ion species could be detected, indicating the isoelectric point. In combination with the measurement of the streaming current, the surface charge of the sample could be quantified. KW - Interfacial charge KW - Solid/liquid interfaces KW - Surface analysis KW - Surface functionalization KW - X-ray spectrometry KW - X-ray KW - Standing waves KW - XSW KW - Streaming current KW - Synchrotron radiation PY - 2010 DO - https://doi.org/10.1002/cphc.201000166 SN - 1439-4235 SN - 1439-7641 VL - 11 IS - 10 SP - 2118 EP - 2123 PB - Wiley-VCH Verl. CY - Weinheim AN - OPUS4-22057 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Constantinescu, B. A1 - Vasilescu, A. A1 - Stan, D. A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Buzanich, Günter A1 - Ceccato, D. A1 - Oberländer-Târnoveanu, E. T1 - Studies on archaeological gold items found in Romanian territory using X-ray-based analytical spectrometry N2 - This paper is an overview of the work developed by our group in the investigations of museum objects and alluvial gold, reflected in a series of studies published between 2000–2011, supplemented with new results, unpublished up-to-date. The X-ray based spectrometric techniques employed range from various X-Ray Fluorescence (XRF) investigations to ion beam analysis, including synchrotron radiation XRF and micro-Particle Induced X-ray Emission. The gold objects discussed are mainly part of the Sarmizegetusa Dacian hoards—spiraled bracelets (armbands) and coins. After obtaining in 2011 the permission of the Romanian authorities to take very small (1–2 mg) samples from the most 'unimportant' areas of the Dacian bracelets and several Koson staters, to analyze them by micro-SR-XRF at BESSY, in February 2012, the investigation of several micro-areas of 17 stater and 28 bracelet samples revealed important micro-structural inhomogeneity, especially in Sn and Cu. The same inhomogeneous micro-structure has been seen in Transylvanian alluvial gold. The analyses revealed details on the fingerprint of geological gold deposits and also the main characteristics of ancient gold metallurgy procedures used by the Dacians: a relatively low temperature (lower than Au melting point) and hammering during heating to obtain an ingot through sintering. The use of the sintering procedure was proved for the spiraled bracelets and the Koson without monogram coins, a tradition starting in the Bronze Age in Transylvanian gold processing. The existence of micro-inclusions of Ta-minerals in alluvial gold was also detected, explaining Ta trace presence in the artifacts from the Pietroasa hoard. KW - Micro-SR-XRF KW - Micro-PIXE KW - Archaeometry KW - Gold KW - Romania PY - 2012 DO - https://doi.org/10.1039/c2ja30158j SN - 0267-9477 SN - 1364-5544 VL - 27 IS - 12 SP - 2076 EP - 2081 PB - Royal Society of Chemistry CY - London AN - OPUS4-26991 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Niemeyer, B. A1 - Schwarzmaier, A. A1 - Radtke, Martin A1 - Hahn, Oliver T1 - Archaische Goldarbeiten aus Kleinasien in der Berliner Antikensammlung – Herstellungstechnik, Materialanalytik und der Fundkomplex »aus Ephesos« N2 - Ein Konvolut einzelner Schmuckstücke und die Goldbeigaben eines angeblichen Grabfundes wurden technologisch und analytisch untersucht. Die meisten Objekte sind Blecharbeiten, die aus einer Vielzahl von Einzelteilen mit metallischem Goldlot zusammengefügt und mit Granulation oder granulations-imitierendem Perl- oder Kerbdraht verziert wurden. Nur vier kleine Ohrringe sind massiv gegossen. Zwei Zierbleche dürften über Patrizen (Positivmodeln), die Deckel der Astragale in Matrizen (Negativmodeln) geformt worden sein. Alle Objekte wurden mit Synchrotron- und atmosphärischer Röntgenfluoreszenz analysiert. Die Daten zeigen das breite Spektrum an Goldlegierungen, die im 7./6. Jahrhundert v. Chr. in Kleinasien verarbeitet wurden: vom natürlichen Seifengold (Elektrum) bis zu geläutertem, fast reinem Gold. Eine Korrelation zwischen Goldqualität und Verarbeitungsmethode konnte nicht festgestellt werden. Sowohl hochreines als auch mit viel Silber und Kupfer legiertes Gold wurde zum Schmieden von Blecharbeiten, aber auch zum Massivguss verwendet. Aus der Goldfarbe kann wegen des Phänomens der oberflächlichen Goldanreicherung nicht auf eine Legierungszusammensetzung geschlossen werden. Der 1963 angekaufte Fundkomplex aus lydischen Metallarbeiten und ostionischen Salbgefäßen aus Ton dürfte einen Grabfund des frühen 6. Jahrhunderts v. Chr. darstellen, dessen Herkunft aus Ephesos jedoch nicht zu sichern ist. KW - Gold KW - Synchrotron KW - XRF PY - 2017 SN - 1866-7007 VL - 9 SP - 57 EP - 83 PB - RGZM. Archäologische Staatssammmlung München CY - München AN - OPUS4-42986 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Constantinescu, B. A1 - Vasilescu, A. A1 - Radtke, Martin A1 - Reinholz, Uwe T1 - Micro-SR-XRF studies for archaeological gold identification - the case of carpathian gold and romanian museal objects N2 - In the determination of the provenance of gold in archaeological artifacts, trace elements are more significant than the main components. Several minute fragments of natural Carpathian gold-placer and primary-and some very small (a few milligrams) fragments of archaeological items were studied using micro Synchrotron Radiation X-Ray Fluorescence (micro SR-XRF) at the BESSY Synchrotron Facility in Berlin, Germany. The goal of the study was to identify the trace elements characterizing Carpathian gold, looking especially at Sn, Sb, Pb and Te, and to determine if the gold in the archaeological items is native or refined. Applications to the authentication and provenance of nine Dacian gold bracelets, koson coins and two Bronze Age items are presented. KW - Gold KW - Provenance KW - Archeometry KW - Sy-XRF PY - 2010 DO - https://doi.org/10.1007/s00339-010-5624-1 SN - 0947-8396 VL - 99 IS - 2 SP - 383 EP - 389 PB - Springer CY - Berlin AN - OPUS4-21395 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Constantinescu, B. A1 - Vasilescu, A. A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Pacheco, C. A1 - Pichon, L. A1 - Oberländer-Târnoveanu, E. T1 - SR XRF and micro-PIXE studies on ancient metallurgy of thirteen Dacian gold bracelets N2 - A thorough microscopic investigation by SR XRF and micro-PIXE brings insight into the probable techniques used in the manufacture of thirteen Dacian gold bracelets, one of the most spectacular archaeological finds ever on the territory of Romania. KW - Micro-SR-XRF KW - Micro-PIXE KW - Archaeometry KW - Gold KW - Romania PY - 2012 DO - https://doi.org/10.1007/s00339-012-7306-7 SN - 0947-8396 VL - 109 IS - 2 SP - 395 EP - 402 PB - Springer CY - Berlin AN - OPUS4-26902 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Babutzka, Martin A1 - Heyn, A. T1 - Dynamic tafel factor adaption for the evaluation of instantaneous corrosion rates on zinc by using gel-type electrolytes N2 - The paper presents a new method for the determination and evaluation of tafel factors using gel-type electrolytes and electrochemical frequency modulation technique (EFM). This relatively new electrochemical method offers the possibility to determine both polarization resistances and tafel factors within one measurement and in short measuring intervals. Starting from a comprehensive parameter study it is shown that a direct relationship between the two values exists that can be described mathematically. This contribution presents the determined tafel factors for the system gel-type electrolyte/zinc and discusses their applicability and their limits. T2 - 19th Chemnitz Seminar on Materials Engineering – 19. Werkstofftechnisches Kolloquium CY - Chemnitz, Germany DA - 16.03.2017 KW - Gel-type electrolytes KW - Gelartige Elektrolyte KW - Zinc KW - Zink KW - Stern Geary constant KW - Stern-Geary-Konstante PY - 2017 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-394324 UR - http://iopscience.iop.org/article/10.1088/1757-899X/181/1/012021/pdf DO - https://doi.org/10.1088/1757-899X/181/1/012021 SN - 1757-899X SN - 1757-8981 VL - 181 IS - Conference 1 SP - Article UNSP 012021, 1 EP - 11 PB - IOP Publishing CY - Bristol, UK AN - OPUS4-39432 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Menzel, M. A1 - Scharf, O. A1 - Novak, S. A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Hischenhuber, P. A1 - Buzanich, Günter A1 - Meyer, A. A1 - Lopez, V. A1 - McIntosh, K. A1 - Streli, C. A1 - Havrilla, G. A1 - Fittschen, U. T1 - Shading in TXRF: calculations and experimental validation using a color X-ray camera N2 - Absorption effects in total reflection X-ray fluorescence (TXRF) analysis are important to consider, especially if external calibration is to be applied. With a color X-ray camera (CXC), that enables spatially and energy resolved XRF analysis, the absorption of the primary beam was directly visualized for mL-droplets and an array of pL-droplets printed on a Si-wafer with drop-on-demand technology. As expected, deposits that are hit by the primary beam first shade subsequent droplets, leading to a diminished XRF signal. This shading effect was quantified with enhanced precision making use of sub-pixel analysis that improves the spatial resolution of the camera. The measured absorption was compared to simulated results using three different model calculations. It was found they match very well (average deviation < 10%). Thus errors in quantification due to absorption effects can be accounted for in a more accurate manner. KW - absorption KW - X-ray Fluorescence analysis PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-359000 DO - https://doi.org/10.1039/C5JA00127G IS - 10 SP - 2184 EP - 2193 PB - Royal Society of Chemistry CY - Cambridge AN - OPUS4-35900 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Hahn, Oliver A1 - Denker, A. A1 - Merchel, S. A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Wolff, T. ED - Armbruster, B. ED - Eilbracht, H. ED - Hahn, Oliver ED - Heinrich-Tamaska, O. T1 - Zerstörungsfreie Analyse von Metallartefakten - Eine Fallstudie N2 - Die naturwissenschaftliche Analyse historischer Materialen ermöglicht die Beantwortung kulturhistorischer Fragestellungen, die mit kunsthistorischen oder archäologischen Ansätzen allein nicht zu leisten sind. In dieser Studie wurden sechs römische Münzen mit unterschiedlich stark ausgeprägten Korrosionsschichten an unbehandelten und polierten Stellen mit vier zerstörungsfreien analytischen Methoden untersucht: Hoch- und Niederenergie Protonen Induzierter Röntgenemission (HE-/PIXE), Synchrotronstrahlungsinduzierte-Röntgenfluoreszenzanalyse (SY-RFA) und Mikro-Röntgenfluoreszenzanalyse (Mikro-RFA) mit einem mobilen Gerät. Aufgrund von Unterschieden in den Messbedingungen und dem Einfluss der Patina-Schichten auf diese ergaben sich nur für wenige Elemente Übereinstimmungen in den quantitativen Daten. Zur Validierung zukünftiger Messkampagnen mit verschiedenen Methoden sind daher Vergleichstudien unerlässlich. N2 - Investigations of physical properties and chemical composition of ancient materials generate important data for answering culture-historical questions that cannot be solved by art historical and archaeological methods alone. This contribution reports on the analysis of six Roman coins, with different degrees of corrosion layers in parts that were not handled or polished, using four non-destructive methods: low-energy particle-induced X-ray emission (PIXE, 2 MeV), high-energy PIXE (68 MeV), μ-X-ray fluorescence (XRF) spectrometry with a portable device and synchrotron-radiation induced XRF. Because of differences in the conditions needed for measurement and the influence of the layers of patina on these measurements, there were few elements where the quantitative data were in agreement. Thus comparative analyses are essential to validate future measurement projects using different methods. KW - Zerstörungsfreie Prüfung KW - Protoneninduzierte Röntgenemission KW - Röntgenfluoreszenzanalyse KW - Non-destructive testing KW - Particle-induced X-ray emission KW - X-ray fluorescence analysis PY - 2016 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-385702 SN - 978-3-9816751-5-3 VL - Berlin studies of the ancient world, Band 35 SP - 117 EP - 137 PB - Edition Topoi CY - Berlin AN - OPUS4-38570 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hachmöller, O. A1 - de Oliveira Guilherme Buzanich, Ana A1 - Aichler, M. A1 - Radtke, Martin A1 - Dietrich, D. A1 - Schwamborn, K. A1 - Lutz, L. A1 - Werner, M. A1 - Sperling, M. A1 - Walch, A. A1 - Karst, U. T1 - Elemental bioimaging and speciation analysis for the investigation of Wilsons disease using μXRF and XANES N2 - A liver biopsy specimen from a Wilson’s disease (WD) patient was analyzed by means of micro-X-ray fluorescence (mXRF) spectroscopy to determine the elemental distribution. First, bench-top mXRF was utilized for a coarse scan of the sample under laboratory conditions. The resulting distribution maps of copper and iron enabled the determination of a region of interest (ROI) for further analysis. In order to obtain more detailed elemental information, this ROI was analyzed by synchrotron radiation (SR)-based mXRF with a beam size of 4 mm offering a resolution at the cellular level. Distribution maps of additional elements to copper and iron like zinc and manganese were obtained due to a higher sensitivity of SR-mXRF. In addition to this, X-ray absorption near edge structure spectroscopy (XANES) was performed to identify the oxidation states of copper in WD. This speciation analysis indicated a mixture of copper(I) and copper(II) within the WD liver tissue. KW - progressive hepatolenticular degeneration KW - mXRF Micro-X-ray fluorescence spectroscopy KW - XANES X-ray absorption near edge structure spectroscopy PY - 2016 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-360811 DO - https://doi.org/10.1039/C6MT00001K SN - 1756-5901 SN - 1756-591X PB - Royal Society of Chemistry CY - Cambridge AN - OPUS4-36081 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -