TY - GEN A1 - Müller, Bernd R. A1 - Lange, Axel A1 - Harwardt, Michael A1 - Hentschel, Manfred P. A1 - Illerhaus, Bernhard A1 - Goebbels, Jürgen A1 - Bamberg, J. A1 - Heutling, F. T1 - 3D Refraction Computed Tomography Applied to Metal Matrix Composites N2 - For the first time Metal Matrix Composites (MMC) have been investigated by 3D Computed Tomography combined with enhanced interface contrast due to X-ray refraction. X-ray refraction is a relatively new approach for the characterization of advanced materials. The related techniques of Refraction Topography and Refraction Computed Tomography have been developed and applied at our laboratory during the last decade to meet the actual demand for improved nondestructive characterization of high performance composites, ceramics and other low density materials and components. X-ray refraction occurs, when X-rays crosses interfaces of spherical or cylindrical shape (e.g. pores or fibres) in the same way as visible light is refracted by lenses. These X-ray optical effects can be observed at small scattering angles of few minutes of arc as the refractive index n of X-rays is nearly unity (n = 1 – 10-6). Due to the short X-ray wavelength of about 0.1 nm the technique determines the amount of inner surfaces and interfaces of nanometer dimensions. The technique is expected to solve many problems in understanding the meaning of micro and sub micro structures in materials science. With the results of the CT investigation, some questions could be clarified for a better understanding of fatigue failure mechanisms under cyclic loading conditions. The specimens for the test programme have been provided by MTU Aero Engines. They consist of a titanium matrix (Ti6242) reinforced by SiC fibres (SCS6). The investigations have been performed at the materials research station of BAM (BAMline) at the Synchrotron Facility BESSY in Berlin, Germany. T2 - 35th International SAMPE technical conference CY - Dayton, OH, USA DA - 2003-09-28 KW - Non-Destructive Inspection (NDI) KW - Characterization KW - Titanium Metal Matrix Composites (Ti-MMC) KW - Ti6242 KW - SCS6 PY - 2003 SN - 0-938994-95-6 PB - SAMPE CY - Covina, Calif. AN - OPUS4-2780 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Müller, Bernd R. A1 - Görner, Wolf A1 - Hentschel, Manfred P. A1 - Riesemeier, Heinrich A1 - Krumrey, M. A1 - Ulm, G. A1 - Diete, W. A1 - Klein, U. A1 - Frahm, R. T1 - BAMlin - the first hard X-ray beamline at BESSY II N2 - The first hard X-ray beamline at BESSY II will be installed by BAM and PTB at a superconducting 7 T wavelength shifter. The main optical elements of the beamline are a Double-Multilayer-Monochromator and a Double-Crystal-Monochromator. The two devices can be used separately or in-line. Main applications of monochromatic radiation with photon energies up to 50 keV are X-ray fluorescence analysis, micro-computed tomography, X-ray topography, detector calibration and reflectometry. Calculable undispersed radiation up to 200 keV will be available for radiometric applications. KW - Double-Multilayer-Monochromator with meridional bender KW - Double-Crystal-Monochromator with sagittal bender KW - X-ray fluorescence analysis KW - Micro-computed tomography KW - X-ray topography KW - Detector calibration KW - Reflectometry PY - 2001 DO - https://doi.org/10.1016/S0168-9002(01)00466-1 SN - 0168-9002 SN - 0167-5087 VL - 467-468 IS - 1 SP - 703 EP - 706 PB - North-Holland CY - Amsterdam AN - OPUS4-1171 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kupsch, Andreas A1 - Hentschel, Manfred P. A1 - Lange, Axel A1 - Müller, Bernd R. T1 - Einfaches Korrigieren des Hinterleuchtens von Röntgendetektoren N2 - Hinterleuchten stellt eine oft unerkannte Fehlweisung in der radiographischen Abbildung mit Flächendetektoren dar, die durch diffuse Umverteilung der Intensität verursacht wird. Dieser Effekt kann die korrekte Transmissions-Intensität eines Probekörpers gemäß dem Lambert-Beer'schen Gesetz erheblich verfälschen. Hinterleuchten wird sowohl mit Bremsstrahlung von Röntgenröhren als auch mit monochromatischer Synchrotronstrahlung beobachtet. Die fehlerhaft reduzierten Schwächungskoeffizienten von einigen 10 % korrelieren mit der Strahlschwächung und dem direkt bestrahlten Detektorbereich. Für eine einfache numerische Korrektur des Hinterleuchtens werden lediglich integrale Intensitätswerte benötigt. KW - Hinterleuchten KW - Röntgendetektor KW - Fluoreszenzschirm KW - Radiographie PY - 2013 DO - https://doi.org/10.3139/120.110478 SN - 0025-5300 VL - 55 IS - 7-8 SP - 1 EP - 5 PB - Hanser CY - München AN - OPUS4-28692 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Müller, Bernd R. T1 - Improved computed tomography by variable desmearing - Model reconstructions by iterative DIRECTT algorithm N2 - Die mitunter erhebliche Verschmierung von computertomograpischen Projektionen durch ausgedehnte Strahlenquellen wird durch eine neuartige Entschmierungsprozedur erheblich reduziert, um eine verbesserte Ortsauflösung der Rekonstruktion zu erreichen. Da die Breite der Verschmierungsfunktion der detektornahen und -fernen Objektelemente sich erheblich unterscheiden kann, muss die Entschmierung variabel sein. Im Gegensatz zu einer für alle Voxel-Positionen identischen Entfaltung, also einer grundsätzlich falschen Voraussetzung, wurde eine implizite Entschmierung entwickelt. Die vorab bekannte positionsabhängige Verschmierung wird auf die iterativ wiederholten Projektionen der Teilrekonstruktionen des DIRECTT-Algorithmus angewandt. Die variabel entschmierten Rekonstruktionen aus den Sinogrammen eines Pixelmodells mit Verschmierungen von 1 bis 5 Pixel erreichen eine Ortsauflösung von nahezu einem Pixel. KW - Computertomographie KW - Neutronen-Tomographie KW - Tomographische Rekonstruktionsalgorithmen PY - 2010 SN - 0025-5300 VL - 52 IS - 6 SP - 394 EP - 400 PB - Hanser CY - München AN - OPUS4-21464 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Kupsch, Andreas A1 - Beckmann, Jörg A1 - Ewert, Uwe A1 - Lange, Axel A1 - Hentschel, Manfred P. ED - Beyerer, J. T1 - Threat detection and characterisation by spectroscopic THz-imaging T2 - 2nd Security Research Conference "Future Security" CY - Karlsruhe, Germany DA - 2007-09-12 KW - Terahertz-Radiography KW - Explosives PY - 2007 SN - 978-3-86644-147-7 SP - 155 EP - 158 PB - Universitätsverl. CY - Karlsruhe AN - OPUS4-16101 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, Bernd R. A1 - Hentschel, Manfred P. A1 - Harbich, Karl-Wolfram A1 - Lange, Axel A1 - Schors, Jörg T1 - Charakterisierung von Mikroschäden in polymeren Faserkompositen mittels Röntgen-Refraktions-Topography T2 - Jahrestagung Zerstörungsfreie Materialprüfung 2001 CY - Berlin, Deutschland DA - 2001-05-21 PY - 2001 UR - http://www.ndt.net/article/dgzfp01/papers/p49/p49.htm N1 - Serientitel: Berichtsband / Deutsche Gesellschaft für zerstörungsfreie Prüfung e. V. – Series title: Berichtsband / Deutsche Gesellschaft für zerstörungsfreie Prüfung e. V. IS - 75-CD PB - DGZfP CY - Berlin AN - OPUS4-1298 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Müller, Bernd R. A1 - Lange, Axel A1 - Harwardt, Michael A1 - Hentschel, Manfred P. ED - Paul Sellin, T1 - Refraction enhanced micro-CT for non-destructive materials characterization T2 - IEEE Nuclear Science Symposium CY - Dresden, Germany DA - 2008-10-19 KW - Synchrotron KW - Micro-CT KW - Refraction PY - 2008 SN - 978-1-4244-2715-4 SN - 1082-2654 SP - 541 EP - 546 AN - OPUS4-18662 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kupsch, Andreas A1 - Beckmann, Jörg A1 - Ewert, Uwe A1 - Hentschel, Manfred P. A1 - Lange, Axel T1 - Terahertz-Radiographie riskanter Substanzen ohne Strahlengefährdung T2 - DGZfP-Jahrestagung 2007 CY - Fürth, Deutschland DA - 2007-05-14 KW - Terahertz-Radiographie KW - Explosivstoffe KW - Nichtmetallische Werkstoffe PY - 2007 SN - 978-3-931381-98-1 SP - 1 EP - 10 PB - DGZfP CY - Berlin AN - OPUS4-16100 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Kupsch, Andreas T1 - Computertomographische Rekonstruktion mit DIRECTT - 2D-Modellrechnungen im Vergleich zur gefilterten Rückprojektion KW - Computer-Tomographie KW - Tomographische Rekonstruktions-Algorithmen PY - 2008 SN - 0025-5300 VL - 50 IS - 5 SP - 272 EP - 277 PB - Hanser CY - München AN - OPUS4-17563 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hentschel, Manfred P. A1 - Lange, Axel A1 - Kupsch, Andreas A1 - Müller, Bernd R. T1 - Rekonstruktion unvollständiger computertomografischer Modelldatensätze mit Directt-Algorithmus N2 - Modellrechnungen zur Rekonstruktion unvollständiger computertomographischer Datensätze werden zur Ermittlung der Vorteile des neuen Directt-Algorithmus gegenüber der konventionellen gefilterten Rückprojektion durchgeführt, insbesondere auch zur Vermeidung experimentell begründeter Unwägbarkeiten. Ein entsprechender Bedarf entsteht seitens erweiterter Forschungsaktivitäten und industrieller Bedürfnisse, wo die Rekonstruktion limitierter Messdatensätze von Artefakten dominiert wird. Die bekanntesten Einschränkungen betreffen das Limited-View- und Few-Angles-Problem sowie die ROI-Situation, die jeweils unabhängig voneinander untersucht werden, in der Anwendung jedoch zumeist undefiniert vermischt sind, wie etwa in der Elektronen-Tomografie. Die hochauflösende Rekonstruktion von Einzelpixeln wird durch die Wahl eines kleinen Modells von nur 1012 Pixeln visualisiert und ist ohne Filterung möglich. Rekonstruktionen von 90°-Sektoren oder 50 % -ROI-Querschnitten sind fast ohne Auflösungseinschränkungen realisierbar. Die bisher nicht bekannte Möglichkeit, auch außerhalb der ROI präzise zu rekonstruieren, wurde als "Extended ROI"-Methode erfolgreich erprobt. KW - Computed tomography KW - Reconstruction algorithm KW - Filtering KW - Limited view KW - Region of interest PY - 2010 SN - 0025-5300 VL - 52 IS - 10 SP - 668 EP - 675 PB - Hanser CY - München AN - OPUS4-22068 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kupsch, Andreas A1 - Beckmann, Jörg A1 - Ewert, Uwe A1 - Hentschel, Manfred P. A1 - Lange, Axel T1 - Terahertz-Wellen: Radiographie ohne Strahlengefährdung N2 - Mit dem Einsatz von Terahertz-Wellen eröffnen sich gegenüber Röntgenstrahlung neuartige Möglichkeiten der Radiologie. Von der dielektrischen Materialcharakterisierung nicht metallischer Werkstoffe bis zur Detektion des Innenlebens von unkonventionellen Spreng- und Brandvorrichtungen (USBV) wird ein großes Anwendungsspektrum für die bildgebende zerstörungsfreie Prüfung abgedeckt. Die physiologische Unbedenklichkeit der Strahlung favorisiert sie auch für Personenkontrollen an Flughäfen. Das Prinzip eines modernen zeitauflösenden Terahertz-Spektrometers mit einer Ortsauflösung bis 0,3mm und einem Frequenzbereich von 0,1 bis 2,2THz wird erläutert sowie die Wechselwirkung mit Materie. Die Besonderheiten von THz-Topogrammen werden am Beispiel einer Briefbombenattrappe mit Röntgen-Radiogrammen verglichen. KW - Terahertz-Radiographie KW - Explosivstoffe KW - Nichtmetallische Werkstoffe PY - 2008 UR - http://materialstesting.de/directlink.asp?MP100891 SN - 0025-5300 VL - 50 IS - 6 SP - 341 EP - 348 PB - Hanser CY - München AN - OPUS4-17598 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Müller, Bernd R. A1 - Lange, Axel A1 - Harwardt, Michael A1 - Hentschel, Manfred P. T1 - Synchrotron Based Micro-CT and Refraction Enhanced Micro-CT of MMC T2 - International Symposium on NDT in Aerospace CY - Fürth, Germany DA - 2008-12-03 KW - X-ray Refraction KW - Synchrotron Radiation KW - Computed Tomography KW - Metal Matrix Composites KW - Lightweight Materials KW - Aerospace PY - 2008 SN - 978-3-940283-12-2 N1 - Serientitel: Berichtsband / Deutsche Gesellschaft für zerstörungsfreie Prüfung e. V. – Series title: Berichtsband / Deutsche Gesellschaft für zerstörungsfreie Prüfung e. V. IS - DGZfP-BB 114 (Poster 10) SP - 295 EP - 305 PB - DGZfP CY - Berlin AN - OPUS4-18607 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Hentschel, Manfred P. A1 - Müller, Bernd R. ED - Czichos, Horst ED - Tetsuya Saito, ED - Leslie Smith, T1 - Computed tomography - Application to composites and microstructures KW - Microstructures KW - Computed tomography KW - X-ray refraction tomography KW - Composites PY - 2006 SN - 978-3-540-20785-6 SP - 870 EP - 875 PB - Springer CY - Berlin AN - OPUS4-14066 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Müller, Bernd R. A1 - Lange, Axel A1 - Hentschel, Manfred P. ED - Cohen, L. J. T1 - Non-Destructive Characterization of High Performance Composites by use of X-Ray Refraction Topography T2 - 48th International SAMPE symposium and exhibition CY - Long Beach, CA, USA DA - 2003-05-11 KW - Non-Destructive Inspection (NDI) KW - Characterization KW - Advanced Composite PY - 2003 SN - 0-938994-94-8 VL - 1 SP - 1203 EP - 1211 PB - SAMPE International Business Office CY - Covina, Calif. AN - OPUS4-2542 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Hentschel, Manfred P. T1 - Verbesserte Computertomographie durch iterative Brennfleckentschmierung T2 - DGZfP-Jahrestagung 2009 CY - Münster, Deutschland DA - 2009-05-18 KW - Computer-Tomographie KW - Rekonstruktionsalgorithmen KW - Ortsauflösung KW - Verschmierung KW - Brennfleck PY - 2009 SN - 978-3-940283-16-0 IS - DGZfP-BB 115 SP - 1 EP - 8 AN - OPUS4-20542 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hentschel, Manfred P. T1 - ZfP von Luftfahrt-Kompositen mittels Röntgen-Refraktion T2 - Seminar "Zerstörungsfreie Prüfung" CY - Stuttgart, Germany DA - 2008-06-13 PY - 2008 AN - OPUS4-18553 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hentschel, Manfred P. T1 - Materialprüfung mit Terahertz-Verfahren T2 - Berliner Wirtschaftsgespräche, DLR CY - Berlin, Germany DA - 2009-03-26 PY - 2009 AN - OPUS4-19272 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hentschel, Manfred P. T1 - Das Anwendungspotential der Röntgen-Topographie vom Mikroriss bis zur Gepäckprüfung T2 - DGZfP-Jahrestagung 2007 CY - Fürth, Germany DA - 2007-05-14 PY - 2007 AN - OPUS4-15481 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hentschel, Manfred P. T1 - Refraktions-Interface-Radiographie T2 - DGZfP-Jahrestagung 2013 CY - Dresden, Germany DA - 2013-05-06 PY - 2013 AN - OPUS4-28493 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Schors, Jörg A1 - Hentschel, Manfred P. A1 - Kupsch, Andreas T1 - Materialcharakterisierung durch tiefenaufgelöste Röntgen-Diffraktometrie T2 - DGZfP Jahrestagung CY - Rostock, Deutschland DA - 2005-05-02 KW - Röntgen-Diffraktions-Mikroskopie KW - Materialcharakterisierung und -identifizierung PY - 2005 SN - 3-931381-64-1 N1 - Serientitel: Berichtsband / Deutsche Gesellschaft für zerstörungsfreie Prüfung e. V. – Series title: Berichtsband / Deutsche Gesellschaft für zerstörungsfreie Prüfung e. V. IS - 94-CD SP - 1(?) EP - 3(?) PB - DGZfP CY - Berlin AN - OPUS4-11696 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Hentschel, Manfred P. T1 - Modellrekonstruktionen unvollständiger computertomographischer Datensätze T2 - DGZfP-Jahrestagung 2010 CY - Erfurt, Deutschland DA - 2010-05-10 KW - Computer-Tomographie KW - Rekonstruktionsalgorithmen KW - Limited view KW - Few angles KW - Region of interest PY - 2010 SN - 978-3-940283-26-9 IS - DGZfP-BB 122 (Poster 17) SP - 1 EP - 7 CY - Berlin AN - OPUS4-21863 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hentschel, Manfred P. T1 - NDE of micro structured materials by X-ray diffraction and refraction topography T2 - SPIE 9th Internat. Symp. NDE for Health Monitoring and Diagnostics CY - San Diego, CA, USA DA - 2004-03-15 PY - 2004 AN - OPUS4-5558 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hentschel, Manfred P. T1 - Computer-Tomographie mit Refraktions-Kontrast und neuem Algorithmus T2 - 12. Sitzung des FA Materialcharakterisierung der DGZfP CY - Stuttgart, Germany DA - 2004-09-29 PY - 2004 AN - OPUS4-5561 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hentschel, Manfred P. T1 - Bildgebende Charakterisierung von Kompositen mit molekularer und mesoskopisch auflösender Röntgen-Streutopographie T2 - Sitzung des DGM-Fachausschusses "Gefüge und Eigenschaften von Polymeren" CY - Kassel, Germany DA - 2008-11-06 PY - 2008 AN - OPUS4-18554 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hentschel, Manfred P. T1 - Röntgen-Streu-Topographie für Aerospace-Werkstoffe T2 - ZFP-Seminar, Airbus Technologies CY - Bremen, Germany DA - 2007-02-06 PY - 2007 AN - OPUS4-15470 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hentschel, Manfred P. T1 - Charakterisierung von Kompositen mittels röntgenoptischer Verfahren T2 - Expertenforum "Strukturmonitoring 2008", VDI/VDE-GMA CY - Nuremberg, Germany DA - 2008-05-06 PY - 2008 AN - OPUS4-18555 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hentschel, Manfred P. T1 - Synchrotron-Refraktions-Computer-Tomographie für die Materialforschung T2 - DGZfP-Jahrestagung 2005 CY - Rostock, Germany DA - 2005-05-02 PY - 2005 AN - OPUS4-11754 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hentschel, Manfred P. T1 - Quantitative X-ray Determination of CFRP Micro Structures T2 - International Symposium on NDT in Aerospace CY - Fürth, Germany DA - 2008-12-03 PY - 2008 AN - OPUS4-18528 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hentschel, Manfred P. T1 - Three-dimensional imaging of magnetic domains T2 - 2nd HZB Joint User's Meeting CY - Berlin, Germany DA - 2010-12-09 PY - 2010 AN - OPUS4-22885 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, Bernd R. A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Kupsch, Andreas ED - Kastner, J. T1 - A comfortable procedure for correcting X-ray detector backlight T2 - Conference on industrial computed tomography CY - Wels, Austria DA - 2012-09-19 KW - X-ray detector backlighting KW - Radiography KW - Fluorescent screen KW - Diffuse background KW - Computed tomography PY - 2012 SN - 978-3-8440-1281-1 SN - 1610-4773 SP - 151 EP - 157 PB - Shaker CY - Aachen AN - OPUS4-26768 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Müller, Bernd R. A1 - Hentschel, Manfred P. A1 - Lange, Axel T1 - Non-destructive evaluation of advanced materials by synchrotron radiation refraction topography PY - 2002 UR - http://www.helmholtz-berlin.de/media/media/oea/web/pr_webseite/druckschriften/berichte/bessy/annualreport2001.pdf#page=233 SN - 0179-4159 SP - 233 EP - 234 PB - Berliner Elektronenspeicherring-Gesellschaft für Synchrotronstrahlung CY - Berlin AN - OPUS4-1326 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Müller, Bernd R. A1 - Ekenhorst, Derk A1 - Brzezinka, Klaus-Werner A1 - Hentschel, Manfred P. ED - Krenkel, W. T1 - Fiber Induced Failure of Carbon/Carbon Composites T2 - 4th International Conference on High Temperature Ceramic Matrix Composites ; 4th HT-CMC Conference CY - Munich, Germany DA - 2001-10-01 PY - 2001 SN - 3-527-30320-0 VL - 4 SP - 175 EP - 180 PB - Wiley-VCH CY - Weinheim AN - OPUS4-1289 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, Bernd R. A1 - Lange, Axel A1 - Harwardt, Michael A1 - Hentschel, Manfred P. T1 - X-Ray refraction computed tomography for NDE of lightweight materials T2 - Deutsche Tagung für Forschung mit Synchrotronstrahlung, Neutronen und Ionenstrahlen an Großgeräten 2006 (SNI2006) CY - Hamburg, Germany DA - 2006-10-04 PY - 2006 AN - OPUS4-15836 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Müller, Bernd R. A1 - Lange, Axel A1 - Hentschel, Manfred P. ED - Green, R. E. ED - Djordjevic, B. B. ED - Hentschel, M. P. T1 - Synchrotron Radiation Refraction Topography PY - 2003 SN - 3-540-40154-7 SP - 167 EP - 176 PB - Springer CY - Berlin AN - OPUS4-2765 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Lange, Axel A1 - Kupsch, Andreas A1 - Hentschel, Manfred P. A1 - Müller, Bernd R. T1 - DIRECTT-Rekonstruktionen im Vergleich zur gefilterten Rückprojektion N2 - Anhand von computertomografischen Messungen und Modellrechnungen werden DIRECTT-Rekonstruktionen im Vergleich mit gefilterten Rückprojektionen bewertet. Dazu wird die Rekonstruktionsqualität mittels einer zirkular erweiterten Modulations-Transfer-Funktion (MTF) und mit integralen Kenngrößen im Radon- und im Ortsraum verglichen. Zur Überprüfung der Rekonstruktionsgenauigkeit experimenteller Daten werden Mustermessungen einfacher Probengeometrien unter definierten physikalischen Bedingungen durchgeführt. Diese beinhalten die Monochromasie, die Unterdrückung von Kantenartefakten und die radiometrische Intensitätsbestimmung. Für die Qualität der Rekonstruktionen mittels DIRECTT erweisen sich sowohl unterschiedliche Rekonstruktionsfilter als auch der Verzicht auf jede Filterung als unerheblich, im Gegensatz zur gefilterten Rückprojektion. KW - Computertomografie KW - Gefilterte Rückprojektion KW - Rekonstruktionsalgorithmen KW - Iterative Rekonstruktion KW - DIRECTT KW - Konvergenz KW - Modulations-Transfer-Funktion (MTF) PY - 2014 UR - http://www.hanser-elibrary.com/doi/pdf/10.3139/120.110610 SN - 0025-5300 VL - 56 IS - 9 SP - 709 EP - 715 PB - Hanser CY - München AN - OPUS4-31378 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Müller, Bernd R. A1 - Hentschel, Manfred P. A1 - Lange, Axel T1 - SYRTOPO - Materialcharakterisierung an der BAMline N2 - Einleitung Die Bundesanstalt für Materialforschung und -prüfung (BAM) hat im Synchrotronstrahlungslabor BESSY (im Wissenschafts- und Technologiezentrum Berlin-Adlershof) ein Röntgen-Strahlrohr (BAMline) sowie einen Messplatz für die zerstörungsfreie Materialcharakterisierung aufgebaut. Der Messplatz erlaubt die Untersuchung mit monochromatischer Röntgenstrahlung im Energiebereich von 5keV bis 60keV mit hohem Photonenfluß. Seit Anfang 2001 läuft der Probebetrieb zur Optimierung der Strahlungsquelle sowie des experimentellen Aufbaus. Die Besonderheiten der BAMline im Vergleich zu Laboröntgenquellen sind der hohe Photonenfluss bei freier Wahl der Photonenenergie sowie die Polarisationseigenschaften und die außerordentliche Parallelität der Strahlung bei großem Strahlungsquerschnitt. Dies ermöglicht Refraktionstopogramme für Metall-Matrix-Komposite (MMC) in relativ kurzer Zeit, mit einer lateralen Ortsauflösung von 10µm, zu messen. Das neuartige ZfP-Verfahren der Röntgen-Refraktions-Topograhy wurde an anderer Stelle ausführlich beschrieben [1,2]. Es nutzt die Messtechnik der traditionellen Kleinwinkelstreuung auf unkonventionelle Weise, und wurde in den letzten zehn Jahren in unserem Labor entwickelte und an die fortgeschrittenen Anforderungen für die zerstörungsfreie Charakterisierung von neuartigen Werkstoffen wie faserverstärkten Kompositen und Keramiken angepasst. Das Verfahren basiert auf dem Brechungseffekt von Röntgenstrahlen. Auf Grund der kurzen Wellenlänge der Röntgenstrahlen (l » 0.1nm) können innere Oberflächen sowie Grenzflächenkonzentrationen von Nanometer Große detektiert werden, so dass mit Hilfe dieser Technik sehr leicht Partikel, Risse und Porengrößen im Sub-Mikrometer-Bereich gemessen werden können, ohne dabei die Proben zu zerstören, wie es bei mikroskopischen Techniken notwendig ist. Anwendungsfelder dieser Untersuchungsmethode sind z.B. die Erkennung von Faser-Matrix-Enthaftung nach Schlageinwirkung sowie Rissbildung durch Alterung und Herstellung bei faserverstärkten Kompositen. T2 - Jahrestagung Zerstörungsfreie Materialprüfung 2002 CY - Weimar, Deutschland DA - 2002-05-06 PY - 2002 UR - http://www.ndt.net/article/dgzfp02/papers/v16/v16.htm SN - 3-931381-39-0 N1 - Serientitel: Berichtsband / Deutsche Gesellschaft für zerstörungsfreie Prüfung e. V. – Series title: Berichtsband / Deutsche Gesellschaft für zerstörungsfreie Prüfung e. V. IS - 80-CD SP - 1(?) EP - 6(?) PB - DGZfP CY - Berlin AN - OPUS4-2793 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lange, Axel A1 - Kupsch, Andreas A1 - Hentschel, Manfred P. A1 - Müller, Bernd R. T1 - Straightforward correction of X-ray detector backlighting N2 - A novel approach to strongly suppress artifacts in radiography and computed tomography caused by the effect of diffuse background signals ('backlighting') of 2D X-ray detectors is suggested. Depending on the detector geometry the mechanism may be different, either based on the optical scattering of the fluorescent screen materials into optical detection devices or Compton or X-ray fluorescence scattering by the detector components. Consequently, these erroneous intensity portions result in locally different violations of Lambert Beer’s law in single projections (radiographs) as function of the detector area coverage and the magnitude of the attenuation. The absorption of multiple metal sheets is investigated by monochromatic synchrotron radiation, thus excluding beam hardening. The proposed correction procedure simply requires the individual subtraction of one and the same fraction of the primary and transmitted mean intensity, as a constant (non-local) scattering mechanism is assumed. T2 - 18th WCNDT - World conference on nondestructive testing CY - Durban, South Africa DA - 2012-04-16 KW - X-ray detector backlighting KW - Radiography KW - Fluorescent screen KW - Diffuse background KW - Computed tomography PY - 2012 UR - http://www.ndt.net/article/wcndt2012/papers/205_wcndtfinal00205.pdf SN - 978-0-620-52872-6 SP - 1 EP - 8(?) AN - OPUS4-25835 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Kupsch, Andreas T1 - True 3D-CT-reconstruction in comparison to the FDK-algorithm T2 - 17th World Conference on Non-Destructive Testing CY - Shanghai, China DA - 2008-10-25 KW - Computed tomography KW - Spatial resolution KW - Reconstruction algorithm PY - 2008 SP - 1 EP - 5 PB - International Committee for Non-Destructive Testing CY - Shanghai AN - OPUS4-18568 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schors, Jörg A1 - Hentschel, Manfred P. A1 - Harbich, Karl-Wolfram A1 - Lange, Axel A1 - Müller, Bernd R. T1 - Röntgen-Topographie mit Klein- und Weitwinkel-Streuung und Röntgenrefraktions-Computertomographie KW - Röntgen-Streuung KW - Materialcharakterisierung KW - Komposite KW - Keramik KW - Risse KW - Computertomographie PY - 2003 SN - 0948-5112 IS - 86 SP - 11 Seiten PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung CY - Berlin AN - OPUS4-2652 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hentschel, Manfred P. A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Müller, Bernd R. T1 - Refraktions-Interface-Radiographie N2 - Nanoskalige Strukturen und Grenzflächen bestimmen zunehmend die Funktionalität moderner Materialien und Bauteile und erfordern ihre zerstörungsfreie Charakterisierung mit angepasster Ortsauflösung. Dazu sind wegen der passenden Wellenlängen Röntgen-Refraktionsverfahren einsetzbar. Die resultierende Kleinwinkelstreuung verursacht lokal große Intensitäten, die durch Umlagerung oder Fokussierungseffekte das Primärstahlniveau übersteigen können. Mit monochromatischer Synchrotronstrahlung an homogenen Musterproben einfacher Geometrien (Platten und Zylinder) wird die Dominanz der Refraktionsintensität gegenüber der Totalreflexion dargestellt. Der Refraktionseffekt kann für Einstrahlwinkel bis zu einigen Grad genutzt werden; die typischen Streuwinkel liegen in der Größenordnung von Bogensekunden bis -minuten. Darüber hinaus wird die Bestimmung der inneren Oberflächen, Poren und Nanorisse auch orientierungsspezifisch mit Laborausrüstungen demonstriert. T2 - DGZfP-Jahrestagung 2013 CY - Dresden, Germany DA - 06.05.2013 KW - Röntgenrefraktion KW - Kleinwinkelstreuung KW - Refraktionstopographie KW - Nanostrukturen PY - 2013 SN - 978-3-940283-49-8 IS - Mo.2.A.2 SP - 1 EP - 10 AN - OPUS4-28691 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Rack, A. A1 - Zabler, S. A1 - Müller, Bernd R. A1 - Riesemeier, Heinrich A1 - Weidemann, Gerd A1 - Lange, Axel A1 - Goebbels, Jürgen A1 - Hentschel, Manfred P. A1 - Görner, Wolf T1 - High resolution synchrotron-based radiography and tomography using hard X-rays at the BAMline (BESSY II) N2 - The use of high brilliance and partial coherent synchrotron light for radiography and computed tomography (CT) allows to image micro-structured, multi-component specimens with different contrast modes and resolutions up to submicrometer range. This is of high interest for materials research, life science and non-destructive evaluation applications. An imaging setup for microtomography and radiography installed at BESSY II (a third generation synchrotron light source located in Berlin, Germany) as part of its first hard X-ray beamline (BAMline) can now be used for absorption, refraction as well as phase contrast — dedicated to inhouse research and applications by external users. Monochromatic synchrotron light between 6 keV and 80 keV is attained via a fully automated double multilayer monochromator. For imaging applications the synchrotron beam transmitted by the sample is converted with a scintillator into visible light. By use of microscope optics this luminescence image is then projected onto, e.g., a CCD chip. Several scintillating materials are used in order to optimise the performance of the detector system. Different optical systems are available for imaging ranging from a larger field of view and moderate resolutions (macroscope — up to 14 mm x 14 mm field of view) to high resolution (microscope — down to 0.35 μm pixel size), offering magnifications from 1.8× to 40×. Additionally asymmetric cut Bragg crystals in front of the scintillator can be used for a further magnification in one dimension by a factor of about 20. Slow and fast cameras are available, with up to 16 bit dynamic range. We show the suitability of the setup for numerous applications from materials research and life science. KW - Microtomography KW - Non-destructive evaluation KW - Synchrotron instrumentation KW - Coherent imaging KW - X-ray refraction KW - Phase contrast KW - Holotomography KW - Synchrotron-CT KW - Scintillator KW - Bragg magnification PY - 2008 DO - https://doi.org/10.1016/j.nima.2007.11.020 SN - 0168-9002 SN - 0167-5087 VL - 586 IS - 2 SP - 327 EP - 344 PB - North-Holland CY - Amsterdam AN - OPUS4-17738 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lange, Axel A1 - Kupsch, Andreas A1 - Müller, Bernd R. A1 - Hentschel, Manfred P. T1 - Edge artefacts of radiographic images by X-ray refraction N2 - The relevance of nano sized structures and interfaces in upcoming technologies requires new non-destructive Xray techniques exploiting attenuation as well as scattering. In the course of driving the resolution and the contrast of modern radiography into micro and nano metre dimension the inevitable scattering effects require increased attention. Several radiologists interpret the observed edge artefacts simply by 'phase contrast' due to different X-ray path lengths within the sample and others refer to Fresnel scattering. The ultra small angle scattering is of high intensity and may reach the level of the primary beam. We present monochromatic synchrotron measurements on rather simply shaped objects (such as plates and cylinders) which prove clearly the dominance of refraction intensity over total reflection and coherent small angle scattering. The refraction conditions hold for angles of incidence of several degrees to the surface, but typical deflection angles range from several seconds to minutes of arc. Additionally to the concept of 'phase contrast' of the primary beam its deflection becomes the essential issue. The appropriate removal of the attenuation contribution enables the imaging of inner surfaces and interfaces by refraction scanning topography. The presented measurements of reference particles demonstrate the reliability of laboratory refraction scanners applying X-ray tubes. T2 - 18th WCNDT - World conference on nondestructive testing CY - Durban, South Africa DA - 2012-04-16 KW - X-ray refraction KW - Small angle scattering KW - Phase contrast radiography KW - Refraction topography KW - Nanostructures KW - Nanocracks PY - 2012 UR - http://www.ndt.net/article/wcndt2012/papers/274_wcndtfinal00274.pdf SN - 978-0-620-52872-6 SP - 1 EP - 11(?) AN - OPUS4-25836 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Lück, S. A1 - Schmidt, V. A1 - Hilger, A. A1 - Garcia-Moreno, F. A1 - Manke, I. T1 - Reconstruction of limited view tomography data by DIRECTT N2 - Incomplete tomographic data sets such as limited view (missing wedge) data represent a well-known challenge for reconstruction algorithms, since they unavoidably lead to substantial image artefacts. Such data sets may occur in industrial computed tomography of limited access (e.g. extended components, fixed objects), directional opacity, limited sample life time or laminographic set-up. We present strategies to effectively suppress the typical elongation artefacts (e.g. lemon-like deformed pores) by our iterative algorithm DIRECTT which offers the opportunity to vary the versatile reconstruction parameters within each cycle. Those strategies are applied to experimental data obtained from metallic foams as well as model simulations. Comparison is drawn to state-ofthe- art techniques (filtered backprojection and algebraic techniques). Further reference is made to reconstructions of complete data sets serving as gold standards. For quantitative assessment of the reconstruction quality adapted techniques based on spatial statistics are introduced. T2 - 18th WCNDT - World conference on nondestructive testing CY - Durban, South Africa DA - 2012-04-16 KW - Computed tomography KW - Limited tomographic data KW - Iterative reconstruction KW - DIRECTT KW - Limited view KW - Missing wedge KW - Spatial statistics PY - 2012 UR - http://www.ndt.net/article/wcndt2012/papers/208_wcndtfinal00208.pdf SN - 978-0-620-52872-6 SP - 1 EP - 9(?) AN - OPUS4-25834 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Manke, I. A1 - Kardjilov, N. A1 - Arlt, Tobias A1 - Grothausmann, R. T1 - Rekonstruktion limitierter CT-Messdatensätze von Brennstoffzellen mit Directt N2 - Die Aufklärung spezifischer Fragestellungen zur Funktionalität von PEM(polymer electrolyte membrane)- und DMFC(Direct Methanol)-Brennstoffzellen bedarf der 3D-Abbildung der spezifischen Komponenten mit unterschiedlichen Strahlungsarten: des Wassergehalts in den Flow Fields mit Neutronen, der Katalysator-Alterung in der MEA (membrane electrode assembly) mit Synchrotronstrahlung und der freien (reaktiven) Katalysator-Oberfläche von Nano-Partikeln mit TEM-Elektronen-Tomografie. Diese Messungen im Bereich der mm- bis nm-Skala unterliegen dabei erheblichen Restriktionen: einer ortsabhängigen Verschmierung der Neutronenradiogramme, Manipulatorinstabilitäten der Synchrotronmessungen sowie einer Kombination von Limited-View-Datensätzen, wenigen Projektionswinkeln und teilweiser Nichtdurchstrahlbarkeit in der Elektronen-CT. Die Vorteile eines fortentwickelten Directt-Algorithmus für die Bewältigung dieser Randbedingungen gegenüber gefilterten Rückprojektionen werden aufgezeigt. KW - Computed tomography KW - Reconstruction algorithm KW - Electron tomography KW - Neutron tomography KW - Catalyst KW - Fuel cell PY - 2010 SN - 0025-5300 VL - 52 IS - 10 SP - 676 EP - 683 PB - Hanser CY - München AN - OPUS4-22070 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Kupsch, Andreas A1 - Müller, Bernd R. T1 - Numerical correction of X-ray detector backlighting N2 - A novel approach to strongly suppress artifacts in radiography and computed tomography caused by the effect of diffuse background signals ('backlighting') of 2D X-ray detectors is suggested. Depending on the detector geometry the mechanism may be different, either based on the optical scattering by the fluorescent screen materials into optical detection devices or Compton or X-ray fluorescence scattering by the detector components. Consequently, these erroneous intensity portions result in locally different violations of Lambert–Beer's law in single projections (radiographs). When used as input data for computed tomography these violations are directly observed via modulation of the projected mass as a function of the rotation phase and the sample’s aspect ratio (dynamics). The magnitude of the diffuse background signal depends on the detector area covered by the projected sample. They are more pronounced the smaller the shadowed area and the stronger the total attenuation. This implies that the reconstruction suffers from additional anisotropic artifacts caused by elongated sample structures. This issue is studied simply by absorption of flat plates in a conventional laboratory radiography set-up and at a synchrotron radiation facility. In the latter case beam hardening artifacts can be excluded due to the monochromatic radiation. The proposed correction procedure requires simple integral intensity offsets as a constant (non-local) light scattering mechanism is assumed. KW - Detector backlighting KW - X-ray detector scattering KW - Fluorescent screen KW - Diffuse background KW - Computed tomography PY - 2012 DO - https://doi.org/10.3139/146.110659 SN - 1862-5282 VL - 103 IS - 2 SP - 174 EP - 178 PB - Carl Hanser CY - München AN - OPUS4-25553 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Ewert, Uwe A1 - Osterloh, Kurt A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Beckmann, Jörg A1 - Hentschel, Manfred P. ED - Beyerer, J. T1 - Advanced radiological technologies for imaging and characterisation of threats T2 - 2nd Security Research Conference "Future Security" CY - Karlsruhe, Germany DA - 2007-09-12 KW - Threat Detection KW - Dual Energy KW - Multiple View Inspection KW - Terahertz Imaging KW - Explosives PY - 2007 SN - 978-3-86644-147-7 SP - 116 EP - 119 PB - Universitätsverl. CY - Karlsruhe AN - OPUS4-18348 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Müller, Bernd R. A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Kupsch, Andreas T1 - A comfortable procedure for correcting X-ray detector backlight N2 - A novel approach is suggested to strongly suppress artifacts in radiography and computed tomography caused by the effect of diffuse background signals 'backlighting' of 2D X-ray detectors. Depending on the detector geometry the mechanism may be different. Either based on the optical scattering of the fluorescent screen materials into the optical detection devices or Compton or X-ray fluorescence scattering by the detector components. Consequently, these erroneous intensity portions result in locally different violations of Lambert Beer's law in single projections (radiographs) as a function of the detector area coverage and the magnitude of the attenuation. The absorption of multiple metal sheets is investigated by monochromatic synchrotron radiation, thus excluding beam hardening. The proposed correction procedure simply requires the individual subtraction of one and the same fraction of the primary and transmitted mean intensity, as a constant (non-local) scattering mechanism is assumed. KW - X-ray detector backlighting KW - Radiography KW - Fluorescent screen KW - Diffuse background KW - Computed tomography PY - 2013 DO - https://doi.org/10.1088/1742-6596/425/19/192015 SN - 1742-6588 SN - 1742-6596 VL - 425 IS - 19 SP - 192015-1 EP - 192015-4 PB - IOP Publ. CY - Bristol, UK AN - OPUS4-28262 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Hentschel, Manfred P. A1 - Müller, Bernd R. A1 - Lange, Axel A1 - Wald, Oliver T1 - Quantitative X-ray Determination of CFRP Micro Structures T2 - International Symposium on NDT in Aerospace CY - Fürth, Germany DA - 2008-12-03 KW - Neutronen-Radiographie KW - Neutronen-Tomographie KW - Tomographische Rekonstruktionsalgorithmen KW - Brennstoffzellen KW - In-Situ Radiologie PY - 2008 SN - 978-3-940283-12-2 N1 - Serientitel: Berichtsband / Deutsche Gesellschaft für zerstörungsfreie Prüfung e. V. – Series title: Berichtsband / Deutsche Gesellschaft für zerstörungsfreie Prüfung e. V. IS - DGZfP-BB 114 (X-Ray/Lecture 13) SP - 89 EP - 98 PB - DGZfP CY - Berlin AN - OPUS4-18606 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Görner, Wolf A1 - Hentschel, Manfred P. A1 - Müller, Bernd R. A1 - Riesemeier, Heinrich A1 - Krumrey, M. A1 - Ulm, G. T1 - The first hard X-rays at the BAMline PY - 2001 UR - http://www.helmholtz-berlin.de/media/media/oea/web/pr_webseite/druckschriften/berichte/bessy/annualreport2000.pdf#page=329 SN - 0179-4159 SP - 329 EP - 331 PB - Berliner Elektronenspeicherring-Gesellschaft für Synchrotronstrahlung CY - Berlin AN - OPUS4-1299 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Hentschel, Manfred P. A1 - Lange, Axel A1 - Müller, Bernd R. A1 - Schors, Jörg A1 - Harbich, Karl-Wolfram T1 - Röntgen-Refraktions-Computer-Tomographie N2 - Für die Charakterisierung Neuer Werkstoffe, vornehmlich Nichtmetalle, hat sich das Verfahren der Röntgen-Refraktions-Topographie bewährt. Es handelt sich phänomenologisch um eine Technik der Röntgen-Kleinwinkel-Streuung mit Probekörper-Abtastung bei fest vorgewähltem Streuwinkel. Gegenüber der klassischen Beugungstheorie dominieren jedoch bei der Streuung an Strukturen oberhalb von 0.3 µm Größe röntgenoptische Brechungseffekte. Detektierbar sind damit innere Ober- und Grenzflächen, insbesondere Mikrorisse unterhalb der lichtmikroskopischen Erkennbarkeit. Da es sich hierbei um eine Durchstrahlungs-Technik handelt, überlagern jedoch die Strukturen zu einer Projektion, analog zu den radiographischen Verfahren. Um auch Informationen entlang der Durchstrahlungs-Richtung in der Tiefe des Probekörpers zu erhalten, wird unter kleinen Streuwinkeln die Computer-Tomographie durchgeführt, im ersten Ansatz mit nur zwei Meßkanälen, jeweils für die Messung der Absorptions- und der Refraktions-Intensität. Dazu werden nacheinander 360 Linear-Scans nach Drehung von jeweils 1° aufgenommen. Die Intensitätswerte werden nach den Regeln der fouriergefilterten Rückprojektion zu Computer-Tomogrammen verarbeitet. Die Ergebnisse visualisieren die Anordnung von Grenzflächen und innere Oberflächen, die sich für zahlreiche nichtmetallische Werkstoffe, vor alllem im Transportmittel-Leichtbau als relevante Mikrostrukturen für das Versagens-Verhalten und die Werkstoff-Optimierung eignen. Zum Vergleich entstehen aus den simultanen Absorptionsmessungen gleichzeitig die klassischen Computer-Tomogramme, die ausschließlich Dichteänderungen anzeigen. T2 - Jahrestagung Zerstörungsfreie Materialprüfung 1999 CY - Celle, Deutschland DA - 1999-05-10 KW - Röntgentomographie KW - Röntgen-Refraktions-Computer-Tomographie PY - 1999 UR - http://www.ndt.net/abstract/dgzfp99/data/40.htm SN - 3-931381-27-7 VL - 1 IS - 68 SP - 361 EP - 369 PB - DGZfP CY - Berlin AN - OPUS4-715 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, Bernd R. A1 - Lange, Axel A1 - Harwardt, Marco A1 - Hentschel, Manfred P. A1 - Illerhaus, Bernhard A1 - Goebbels, Jürgen T1 - Synchrotron Refraction CT and Synchrotron Bragg Magnification CT for NDE T2 - International Symposium on Digital industrial Radiology and Computed Tomography (DIR 2007) CY - Lyon, France DA - 2007-06-25 KW - X-ray Refraction KW - Diffraction Enhanced Imaging (DEI) KW - Bragg Magnification KW - Synchrotron Radiation KW - Computed Tomography (CT) KW - Metal Matrix Composites (MMC) KW - Lightweight Materials KW - Aerospace PY - 2007 IS - CD-ROM SP - 1 EP - 8 CY - Lyon, France AN - OPUS4-16366 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Hentschel, Manfred P. A1 - Müller, Bernd R. A1 - Harwardt, Michael A1 - Lange, Axel T1 - Synchrotron-Refraktions-Computer Tomographie für die Materialforschung T2 - DGZfP Jahrestagung CY - Rostock, Deutschland DA - 2005-05-02 KW - Computer-Tomographie KW - Synchrotronstrahlung KW - Refraktionskontrast KW - Bragg-Vergrößerung PY - 2005 SN - 3-931381-64-1 N1 - Serientitel: Berichtsband / Deutsche Gesellschaft für zerstörungsfreie Prüfung e. V. – Series title: Berichtsband / Deutsche Gesellschaft für zerstörungsfreie Prüfung e. V. IS - 94-CD SP - 1(?) EP - 7(?) PB - DGZfP CY - Berlin AN - OPUS4-11698 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CHAP A1 - Müller, Bernd R. A1 - Hentschel, Manfred P. ED - Czichos, Horst T1 - Micro-diagnostics: X-ray and synchrotron techniques N2 - Beyond classical X-ray techniques are used for the purpose of preferably short-term applications, but some supplementary X-ray and synchrotron techniques for higher resolution microdiagnostics take advantage of scattering effects. In contrast to directly imaging methods their resolution is only limited by the diffraction limit of the X-ray wavelength, far below the atomic dimensions. These techniques of scanning topography and refraction synchrotron tomography may permit the systematic diagnostics for finding and exploiting structure/property relations like correlations among atomic, nano and microstructures with macroscopic properties. Their basic advantage over microscopic techniques is their potential for the non-destructive characterisation of materials, far from invasive sample treatments. They combine scattering and spatial resolution. KW - X-ray KW - X-ray refraction KW - X-ray refraction topography KW - X-ray refraction tomography KW - X-ray scattering KW - USAXS KW - Wide angle X-ray scattering KW - WAXS KW - Interfaces KW - Inner surface density KW - Diffraction enhanced imaging KW - DEI KW - Synchrotron radiation KW - Synchrotron refraction computed tomography KW - SRCT KW - Fibre orientation KW - X-ray diffraction microscopy PY - 2013 SN - 978-3-642-25849-7 SN - 978-3-642-25850-3 DO - https://doi.org/10.1007/978-3-642-25850-3_14 IS - Chapter 14 SP - 287 EP - 300 PB - Springer CY - Berlin Heidelberg AN - OPUS4-27746 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CHAP A1 - Fensch-Kleemann, Elisabeth A1 - Müller, Bernd R. A1 - Harbich, Karl-Wolfram A1 - Hentschel, Manfred P. ED - Kriegesmann, J. T1 - Gefügeanalyse keramischer Werkstoffe mittels Röntgen-Refraktion PY - 2002 SN - 3-87156-091-X IS - Kap. 6.1.4.1 SP - 1 EP - 24 PB - Deutscher Wirtschaftsdienst CY - Köln AN - OPUS4-2066 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Hentschel, Manfred P. T1 - Computertomographische 2D-Rekonstruktionen ohne gefilterte Rückprojektion mit DIRECTT T2 - DACH-Jahrestagung 2008 CY - St. Gallen, Schweiz DA - 2008-04-28 KW - Computer-Tomographie KW - Rekonstruktionsalgorithmen KW - Ortsauflösung PY - 2008 SN - 978-3-940283-09-2 IS - DGZfP-BB 113 (Poster 10) SP - 1 EP - 6 AN - OPUS4-17937 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ewers, Benjamin A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Hentschel, Manfred P. T1 - Terahertz spectral imaging techniques in NDT: Topography and computed tomography N2 - The emerging technology of generation and detection of Terahertz waves (1 THz = 1012 Hz) offers diverse potentials in non-destructive testing (NDT) regarding security as well as safety aspects. Herein, we focus on the latter with emphasis on imaging techniques. The THz range (0.1 … 10 THz, 3mm …30 µm) closes the technological gap between ultra high frequency electronics and FIR optics in the electro-magnetic (EM) spectrum. Electro-optical sampling provides straight access to the EM wave including its phase (rather than intensity). THz waves are well suited to characterize non-metallic materials since they penetrate paper, plastics, ceramics and certain composites (e.g. GFC). We employ a commercial fibre-coupled THz time domain spectrometer (TDS) for scanning the samples laterally through a focal spot. At each position the entire temporal pulse train is recorded, which offers the opportunity to use various parameters derivable for imaging. Topographic measurements are performed as reflection set-up. The achievable spatial resolution is diffraction limited at about 100 µm -300 µm (which allows for perception of single defects on a sub-mm scale). In contrast to typical pulse echoed ultrasound testing THz topography is a non-contact inspection tool without coupling agents. Several reflections of subsequent concealed layers are detected instead of just the first encountered one. Comparing to X-ray (radiology) the non-ionizing THz-waves generate images of similar contrast regarding metal and plastic (organic) components, while conventional radiography emphasizes one type of material depending on the energy preselected. Moreover, the full temporal information is exploited to derive spectra in certain selected time windows, i.e. separated spectral properties of each layer in multilayered structures. Tomographic measurements are performed in transmission mode. The sample is mounted on a rotation stage in order to allow for lateral scanning under the different projection angles. The reconstruction is typically performed by filtered backprojection, which is widely used for X-ray CT. The adaption of this technique to the THz range comes along with several experimental drawbacks such as considerable refraction and scattering. According to these difficulties we investigate the occurring artefacts. The THz-TDS provides the opportunity to calculate a separate backprojection of each frequency interval as obtained by the Fourier transformation of the recorded time resolved amplitude. This results in a spectrally resolved reconstruction of each voxel, which is unique in computed tomography technology. T2 - 10th European conference on non-destructive testing CY - Moscow, Russia DA - 2010-06-07 KW - Terahertz time domain spectroscopy KW - Spectral computed tomography KW - 3D topography PY - 2010 UR - http://www.ndt.net/article/ecndt2010/reports/1_09_10.pdf IS - Paper 4.02.18 SP - 1 EP - 10(?) AN - OPUS4-21465 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Hentschel, Manfred P. A1 - Harbich, Karl-Wolfram A1 - Müller, Bernd R. A1 - Lange, Axel A1 - Schors, Jörg A1 - Wald, Oliver ED - Gerhard Busse, ED - Danny Van Hemelrijck, ED - Igor Solodov, ED - Anastasopoulos, Athanasios T1 - NDE of micro structured materials by X-ray diffraction and refraction topography T2 - 4th International Conference of Emerging Technologies in Non-Destructive Testing (ETNDT 4) CY - Stuttgart, Germany DA - 2007-04-02 KW - Nondestructive testing KW - X-ray scattering KW - X-ray topography KW - Computed topography KW - Synchrotron refraction computed tomography KW - Structure property relations KW - Composite damaging KW - Ceramics KW - Foams PY - 2007 SN - 978-0-415-46476-5 SP - 15 EP - 22 PB - Taylor & Francis CY - London, UK AN - OPUS4-17561 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Kupsch, Andreas A1 - Müller, Bernd R. T1 - Correction of diffuse X-ray detector based background N2 - A novel approach to strongly suppress artifacts in radiography and computed tomography caused by the effect of diffuse background Signals (“backlight”) of 2D X-ray detectors is suggested. Depending on the detector geometry the mechanism may be different, either based on the optical scattering of the fluorescent screen materials into optical detection devices or Compton or X-ray fluorescence scattering by the detector components. Consequently, these erroneous intensity portions result in locally different violations of Lambert Beer’s law in single projections (radiographs). When used as input data for computed tomography these violations are directly observed via modulation of the projected mass as a function of the rotation Phase and the sample’s aspect ratio (dynamics). The magnitude of the diffuse Background signal depends on the detector area covered by the projected sample. They are more pronounced the smaller the shaded area and the stronger the total attenuation. Moreover, the local intensity mismatch depends on the attenuation of the sample. We present very basic reference data measured with multiple metal foils at a synchrotron radiation source. Beam hardening artifacts can be excluded due to the monochromatic radiation. The proposed correction procedure assumes a constant (non-local) scattering mechanism. T2 - DIR 2011 - International symposium on digital industrial raidology and computed tomography CY - Berlin, Germany DA - 20.06.2011 KW - Backlight KW - X-ray detector KW - Fluorescence screen KW - Synchrotron radiography KW - Computed tomography PY - 2011 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-243589 SN - 978-3-940283-34-4 IS - DGZfP-BB 128 (Poster 24) SP - 1 EP - 7 PB - Deutsche Gesellscahft für Zerstörungsfreie Prüfung e.V. (DGZfP) AN - OPUS4-24358 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Kupsch, Andreas T1 - Bewertung von CT-Rekonstruktionen mit DIRECTT N2 - Modellrechnungen mit dem CT-Algorithmus DIRECTT (Direkte iterative Rekonstruktion computertomographischer Trajektorien) haben die Vorteile gegenüber anderen Ansätzen bezüglich Ortsauflösung und Dichte gezeigt, insbesondere auch für unvollständige Datensätze wie Limited View- und Region of Interest-Szenarien. Entsprechend dem Normalfall werden hier jedoch vollständige Datensätze von Modellen und Messungen und ihre Rekonstruktionen bewertet. Die Qualität von DIRECTT wird mit der Gefilterten Rückprojektion anhand der Modulations-Transfer-Funktion (MTF) sowie integraler Kenngrößen im Radon- und im Ortsraum verglichen. Zur Überprüfung der Rekonstruktionsgenauigkeit experimenteller Daten werden Mustermessungen einfacher Probengeometrien unter definierten physikalischen Bedingungen durchgeführt. Diese betreffen Monochromasie, Unterdrückung von Kantenartefakten und radiometrische Intensitätsbestimmung mit Einkanaldetektor. T2 - DGZfP-Jahrestagung 2013 CY - Dresden, Germany DA - 06.05.2013 KW - Computertomographie KW - DIRECTT KW - Modulations-Transfer-Funktion KW - CT-Algorithmus PY - 2013 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-286933 SN - 978-3-940283-49-8 IS - Poster 13 SP - 1 EP - 10 PB - Deutsche Gesellschaft für zerstörungsfreie Prüfung e.V. (DGZfP) AN - OPUS4-28693 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Manke, I. A1 - Kardjilov, N. A1 - Schäfer, R. A1 - Hilger, A. A1 - Grothausmann, R. A1 - Strobl, M. A1 - Dawson, M. A1 - Grünzweig, C. A1 - Tötzke, C. A1 - David, C. A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Banhart, J. T1 - Three-dimensional imaging of magnetic domains with neutron grating interferometry N2 - This paper gives a brief overview on3D imaging of magnetic domains with shearing grating neutron tomography. We investigated the three-dimensional distribution of magnetic domain walls in the bulk of a wedge-shaped FeSi single crystal. The width of the magnetic domains wasanalyzed at different locations within the crystal. Magnetic domains close to the tip of the wedge are much smaller than in the bulk. Furthermore, the three-dimensional shape of individual domains wasinvestigated. We discuss prospects and limitations of the applied measurement technique. KW - Neutron imaging KW - Tomography KW - Magnetic domains KW - Grating interferometry KW - Darkfield imaging KW - Shearing gratings KW - Talbot-Lau KW - Three-dimensional data quantification KW - Tomographic reconstruction PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-341919 DO - https://doi.org/10.1016/j.phpro.2015.07.057 SN - 1875-3892 VL - 69 SP - 404 EP - 412 PB - Elsevier B.V. CY - Amsterdam AN - OPUS4-34191 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kupsch, Andreas A1 - Hentschel, Manfred P. A1 - Lange, Axel A1 - Grothausmann, R. A1 - Manke, I. T1 - Application of the DIRECTT algorithm to sub-nanometer electron tomography N2 - Tomography data obtained from transmission electron microscopes are especially attractive due to their unrivaled spatial resolution in the nanometer range or even less, but they require enormous efforts in sample preparation and suffer from a diverse accumulation of experimental restrictions, which unavoidably result in fundamental reconstruction artifacts. These restrictions refer to: partial opacity, a limited view (limited angle or missing wedge), very few angles (with respect to the detector size), limited to a region of interest (ROI; due to the sample size), variable angular increments as well as sample degradation due the interactions with the electron beam. An advanced version of the DIRECTT (Direct Iterative Reconstruction of Computed Tomography Trajectories) algorithm proves to cope with most of these severe deviations from ideal CT measuring conditions. However, careful data preprocessing is required in order to exploit the capabilities of the algorithm. Nanometer sized Ruthenium catalyst particles for fuel cell applications are 3D imaged at a few Ångström resolution in order to estimate their partial free surface on carbon black supports, which rule the efficiency of the catalytic activity. Comparisons of DIRECTT reconstructions to the conventional filtered back projection, prove the significant improvements. T2 - DIR 2011 - International symposium on digital industrial raidology and computed tomography CY - Berlin, Germany DA - 20.06.2011 KW - Electron tomography KW - Computed tomography KW - Reconstruction algorithms PY - 2011 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-243577 SN - 978-3-940283-34-4 IS - DGZfP-BB 128 (Tu.3.3) SP - 1 EP - 6 PB - Deutsche Gesellscahft für Zerstörungsfreie Prüfung e.V. (DGZfP) AN - OPUS4-24357 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lange, Axel A1 - Kupsch, Andreas A1 - Hentschel, Manfred P. A1 - Lück, S. A1 - Schmidt, V. A1 - Grothausmann, R. A1 - Hilger, A. A1 - Manke, I. T1 - Reduzierung von Missing-Wedge-Artefakten mit DIRECTT N2 - Wir stellen eine Prozedur vor, mit der typische 'Missing Wedge' (MW)-Artefakte in CT-Rekonstruktionen effektiv unterdrückt werden können. Dazu wird der iterative DIRECTT-Algorithmus (Direkte Iterative Rekonstruktion Computertomographischer Trajektorien) mit einigen Zyklen diskreter Rekonstruktion eingesetzt. Die Kernfunktionen des Algorithmus', die wiederholte Auswahl und Gewichtung von Elementen einer Zwischenkonstruktion, werden beibehalten. Abgesehen von Sonderfällen der Röntgen- und Neutronentomographie tritt die MW-Restriktion (neben einer Vielzahl anderer) in Standardkonfigurationen der Elektronentomographie auf. Um den MW-Effekt isoliert zu untersuchen und beurteilen zu können, werden hier vollständige experimentelle Datensätze einer bekannten Porenstruktur um einen Sektor beschnitten sowie MW-Rekonstruktionen von Porenmodellen erzeugt. Die Ergebnisse werden mit zurzeit verbreiteten Algorithmen (Gefilterte Rückprojektion (FBP) und ART-Varianten) verglichen. Die Bewertung im Fourierraum zeigt, dass DIRECTT die fehlende Information im MW erfolgreich ergänzt. Zur quantitativen Bewertung der lokalen Rekonstruktionsqualität werden Methoden der räumlichen Statistik eingesetzt. T2 - DGZfP-Jahrestagung 2014 CY - Potsdam, Germany DA - 26.05.2014 KW - Computertomographie (CT) KW - Rekonstruktionsalgorithmus KW - DIRECTT KW - Missing Wedge KW - Statistische Bewertung PY - 2014 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-312977 SN - 978-3-940283-61-0 IS - DGZfP-BB 148 SP - Poster 18, 1 EP - 8 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) AN - OPUS4-31297 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kupsch, Andreas A1 - Hentschel, Manfred P. A1 - Lange, Axel A1 - Müller, Bernd R. T1 - Röntgen-Interface-Radiographie im Dunkelfeld N2 - Es wird ein Verfahren zur Röntgenabbildung schwach absorbierender Objekte vorgestellt. Als kontrastgebender Effekt wird die Röntgenrefraktion an Ober- und Grenzflächen ausgenutzt. Zur Erzeugung eines sogenannten Dunkelfeldes wird ein schwach gekrümmter Transmissionskristall eingesetzt, der lokal, d.h. in einem kleinen Ausschnitt des Einstrahlquerschnitts, die Bragg-Bedingung erfüllt. Innerhalb dieser Zone erscheinen die durch Refraktion abgelenkten Strahlkomponenten als hell leuchtende Interface-Strukturen. Die Synthese mehrerer Dunkelfeldstreifen ergibt hochaufgelöste 2D Beispiel von biologischen und technischen Mikrostrukturen. T2 - DGZfP-Jahrestagung 2013 CY - Dresden, Germany DA - 06.05.2013 KW - Refraction enhanced imaging (REI) KW - Radiographie KW - Dunkelfeldabbildung KW - Röntgenrefraktion PY - 2013 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-286900 SN - 978-3-940283-49-8 IS - Di.3.C.1 SP - 1 EP - 7 PB - Deutsche Gesellschaft für zerstörungsfreie Prüfung e.V. (DGZfP) AN - OPUS4-28690 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Grothausmann, R. A1 - Manke, I. T1 - Verbesserte Elektronen-Tomographie mittels DIRECTT-Algorithmus N2 - Tomographische Messungen in Transmissions-Elektronenmikroskopen beziehen ihren Reiz aus der hohen Ortsauflösung im Nanometerbereich. Allerdings bringen sie neben dem hohen Aufwand bei der Probenpräparation auch eine außerordentliche Häufung von Restriktionen der Messung mit sich, die bei Verwendung herkömmlicher Rekonstruktionsalgorithmen zu erheblichen Artefakten führen. Diese Restriktionen betreffen: partielle Nichtdurchstrahlbarkeit, einen eingeschränkten Winkelbereich, wenige Projektionen in Bezug auf die Detektorgröße, Probenabbildungen größer als der Detektor, instabile Rotationsachse, variierende Winkelinkremente sowie Probenveränderungen während der Messung. Der DIRECTT-Algorithmus (Direkte iterative Rekonstruktion computertomographischer Trajektorien) kann, abgesehen von der Probenveränderung, sämtliche dieser Restriktionen geeignet berücksichtigen. Die auftretenden, teils unvollständigen Bahnen lassen sich mittels einer Treffertabelle und geeigneter Auswahl iterativ behandeln. Außerdem kann das Rekonstruktionsvolumen über die Detektorlänge hinaus erweitert werden. Damit gelingt eine weitgehende Unterdrückung von Rekonstruktionsartefakten, insbesondere der sonst dominanten Streifenartefakte, und eine deutliche Erhöhung der Ortsauflösung. Die Verbesserung der Rekonstruktionsqualität wird anhand von Modell- und experimentellen Daten gezeigt. T2 - DGZfP-Jahrestagung 2011 CY - Bremen, Germany DA - 30.05.2011 KW - Elektronen-Tomographie KW - Computer-Tomographie KW - Rekonstruktionsalgorithmen PY - 2011 SN - 978-3-940283-33-7 IS - DGZfP-BB 127 (P8) SP - 1 EP - 7 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) AN - OPUS4-25004 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Lück, S. A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Schmidt, V. T1 - Statistical analysis of tomographic reconstruction algorithms by morphological image characteristics N2 - We suggest a procedure for quantitative quality control of tomographic reconstruction algorithms. Our task-oriented evaluation focuses on the correct reproduction of phase boundary length and has thus a clear implication for morphological image analysis of tomographic data. Indirectly the method monitors accurate reproduction of a variety of locally defined critical image features within tomograms such as interface positions and microstructures, debonding, cracks and pores. Tomographic errors of such local nature are neglected if only global integral characteristics such as mean squared deviation are considered for the evaluation of an algorithm. The significance of differences in reconstruction quality between algorithms is assessed using a sample of independent random scenes to be reconstructed. These are generated by a Boolean model and thus exhibit a substantial stochastic variability with respect to image morphology. It is demonstrated that phase boundaries in standard reconstructions by filtered backprojection exhibit substantial errors. In the setting of our simulations, these could be significantly reduced by the use of the innovative reconstruction algorithm DIRECTT. KW - Tomography KW - Computed tomography KW - Reconstruction algorithm KW - Morphological image analysis KW - Phase boundary KW - Metrology KW - Non-destructive testing PY - 2010 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-210710 DO - https://doi.org/10.5566/ias.v29.p61-77 SN - 1580-3139 SN - 1854-5165 VL - 29 SP - 61 EP - 77 CY - Ljubljana, Slovenia AN - OPUS4-21071 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bruno, Giovanni A1 - Hentschel, Manfred P. A1 - Onel, Yener A1 - Lange, Axel A1 - Kupsch, Andreas A1 - Wolk, Thomas A1 - Staude, Andreas A1 - Ehrig, Karsten A1 - Müller, Bernd R. T1 - Bewertung von Porositätsparametern in Cordierit-Diesel-Partikelfilter-Materialien mit fortgeschrittenen Röntgenverfahren und statistischer Analyse N2 - Bikontinuierliche poröse Keramiken für Filteranwendungen weisen eine komplizierte Mikrostruktur auf, in der Poren und Festkörperphase 'vermischt' sind. Mechanische, thermische sowie Filtereigenschaften können nur präzise bestimmt werden, wenn die Morphologie beider Phasen quantitativ angegeben werden kann. Hier werden unter Anwendung von 3D Computertomographie (CT) und verschiedenen Techniken, die auf der Röntgenrefraktion basieren, die Porosität und die Porenorientierung in keramischen Cordierit-Dieselpartikelfiltern bewertet. Dabei werden zur Auswertung der Tomogramme die Fouriertransformierten sowie eine neu entwickelte richtungssensitive Bildanalyse (DIVA, directional interface variance analysis) angewandt. Sowohl die genannten Messtechniken als auch der statistische Ansatz gestatten die Extraktion optional ortsaufgelöster oder gemittelter Werte. Es ergeben sich sehr gute Übereinstimmungen der experimentell ermittelten Porositätswerte mit Ergebnissen aus Quecksilberintrusionsversuchen als auch der ermittelten Porenorientierung im Vergleich zu publizierten Angaben zur kristallographischen Textur. Dies legt den Schluss nahe, dass die Kenntnis der Grenzflächen (zwischen Poren und Materie) genügt, die morphologischen Eigenschaften solcher Materialien hinreichend zu beschreiben. T2 - DGZfP-Jahrestagung 2014 CY - Potsdam, Germany DA - 26.05.2014 KW - Cordierit KW - Poröse Keramik KW - Porenorientierung KW - Röntgenrefraktion KW - Computer-Tomographie KW - 3D-Mikrostruktur PY - 2014 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-312946 SN - 978-3-940283-61-0 VL - 148 SP - 1 EP - 8 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) CY - Berlin AN - OPUS4-31294 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Jaenisch, Gerd-Rüdiger A1 - Kardjilov, N. A1 - Tötzke, C. A1 - Markötter, Henning A1 - Hilger, A. A1 - Manke, I. T1 - Compton-CT als Alternative zur Neutronentomographie? N2 - Als Alternative zur Neutronentomographie wird das Potenzial der Computertomographie (CT) mit inkohärenter Röntgen-Streustrahlung (Compton-Streuung) untersucht. Die gleichzeitige Abbildung von Materialien sehr unterschiedlicher Dichten (Ordnungszahlen) ist eine wiederkehrende Herausforderung für die Radiologie und die Computertomographie mit Röntgenstrahlung. Die Messungen ergeben asymmetrische Projektionsprofile für Sinogramme der Streuintensität. Am Beispiel verschiedener Polymere (Polyethylen, Polyamid, PVC), Glas und Holz wird in den Tomogrammen ein hochaufgelöster 'Comptonkontrast' vergleichbarer Dynamik erreicht, während der simultan gemessene 'Absorptionskontrast' ausschließlich die starken Absorber (Glas und PVC) zeigt. Der Vergleich mit ähnlich auflösender Neutronentomographie zeigt ähnliche Kontraste und eröffnet mithin die Möglichkeit, diese künftig durch Compton-Tomographie im Labormaßstab zu ersetzen. T2 - DACH-Jahrestagung 2015 CY - Salzburg, Austria DA - 11.05.2015 KW - Comptonstreuung KW - Computertomographie KW - Neutronentomographie PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-342894 SN - 978-3-940283-68-9 IS - DGZfP BB 152 SP - Mo.3.A.2, 1 EP - 10 AN - OPUS4-34289 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kupsch, Andreas A1 - Hentschel, Manfred P. A1 - Lange, Axel A1 - Bruno, Giovanni A1 - Müller, Bernd R. T1 - Direkte Röntgenrefraktion an Mikrostrukturen N2 - Die durch Brechung an Mikrostrukturen abgelenkte Röntgenstrahlung wird direkt zweidimensional abgebildet. Dazu werden Modellproben einfacher Geometrie (Fasern, Kapillaren, monodisperse Nano- und Mikropartikel) mit einem auf 50 µm kollimierten Synchrotronstrahl (20 keV) gescannt. Die nach den Regeln der geometrischen Optik an prismatischen und linsenartigen Grenzflächen abgelenkte Strahlung wird in etwa 3 Metern Entfernung von einem Flächendetektor mit 7 µm Ortsauflösung zusätzlich zu der ungestörten Resttransmission des Primärstrahls registriert. In der Abfolge der Radiogramme werden die lokalen Orientierungsänderungen der Probekörper-Grenzflächen bei deren Abtastung mit wenigen Mikrometern Schrittweite bildhaft verfolgt. Mit der hier erreichten Winkelauflösung von etwa 3 Bogensekunden (Streuvektor-Inkremente Δk = 10-3nm-1) kann bei 50 µm Ortsauflösung das Materialvolumen bezüglich innerer Grenzflächen mit Nanometer-Separation auch bei hohen Abtastraten unterhalb einer Sekunde pro Bild charakterisiert werden. T2 - DGZfP-Jahrestagung 2014 CY - Potsdam, Germany DA - 26.05.2014 KW - Computertomographie (CT) KW - Rekonstruktionsalgorithmus KW - DIRECTT KW - Missing wedge KW - Statistische Bewertung PY - 2014 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-312931 UR - http://www.ndt.net/article/dgzfp2014/papers/di1b2.pdf SN - 978-3-940283-61-0 IS - DGZfP-BB 148 SP - Di.1.B.2, 1 EP - 9 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) CY - Berlin AN - OPUS4-31293 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Shashev, Yury A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Britzke, Ralf A1 - Bruno, Giovanni A1 - Mueller, Bernd R. A1 - Hentschel, Manfred P. T1 - Talbot- Lau interferometry with a non- binary phase grating for non-destructive testing N2 - Grating interferometric set-ups have been established in the last decade. They are promising candidates to obtain enhanced image contrast from weakly absorbing micro and nano structures. They are based on X-ray refraction and near-field diffraction using the Talbot effect. At the expense of taking multiple images, Talbot-Lau grating interferometry allows separating the absorption, refraction, and scattering contributions by analysing the disturbances of a phase grating interference pattern. Contrary to other refraction enhanced methods, this technique can be applied using conventional X-ray tubes (divergent, polychromatic source). This makes it attractive to solve typical non-destructive testing problems. We investigated the efficiency of phase gratings, i.e. the visibility (the amplitude of oscillations) upon variation of propagation distance and phase grating rotation around an axis parallel to the grid lines. This grating rotation changes the grating shape (i.e. the distributions of phase shifts). This can yield higher visibilities than derived from rectangular shapes. Our study includes experimental results obtained from synchrotron radiation, as well as simulations for monochromatic radiation. The advantages of Talbot-Lau interferometry are demonstrated at the example of glass capillaries. T2 - WCNDT2016 CY - Munich, Germany DA - 13.06.2016 KW - Phase-contrast X-ray imaging KW - Talbot- Lau interferometry KW - Phase grating KW - Visibility KW - Synchrotron radiation PY - 2016 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-365987 SN - 978-3-940283-78-8 VL - BB 158 SP - Tu.3.G.2., 1 EP - 9 AN - OPUS4-36598 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Markötter, Henning A1 - Manke, I. A1 - Kuhn, R. A1 - Arlt, Tobias A1 - Kardjilov, N. A1 - Hentschel, Manfred P. A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Hartnig, C. A1 - Scholta, J. A1 - Banhart, J. T1 - Neutron tomographic investigations of water distributions in polymer electrolyte membrane fuel cell stacks N2 - Neutron tomography was applied to study the 3D water distribution in full polymer electrolyte membrane fuel cell (PEMFC) stacks. The water distribution after switch-off of the fuel cell was analyzed over a period of 36 h. We found a slowly increasing water amount in the fuel cell, but only few changes within a time period of 5 h, which is about the time necessary for neutron tomography. In this way, the requirement for successful tomography was obtained. It is demonstrated how the quasi in-situ tomography technique enables us to study the water content in individual flow field channels of three-fold stacks. Flow field as well as stack design issues are addressed by this visualization method showing weak points due to a non-uniform water distribution that can be identified by means of neutron imaging. KW - Radiography KW - Tomography KW - Neutron imaging KW - Polymer electrolyte membrane fuel cell (PEMFC) KW - Manifold stack KW - Water management PY - 2012 DO - https://doi.org/10.1016/j.jpowsour.2012.07.043 SN - 0378-7753 VL - 219 SP - 120 EP - 125 PB - Elsevier CY - Amsterdam [u.a.] AN - OPUS4-26317 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Müller, Bernd R. A1 - Cooper, R.C. A1 - Lange, Axel A1 - Kupsch, Andreas A1 - Wheeler, M. A1 - Hentschel, Manfred P. A1 - Staude, Andreas A1 - Pandey, A. A1 - Shyam, A. A1 - Bruno, Giovanni T1 - Stress-induced microcrack density evolution in β-eucryptite ceramics: Experimental observations and possible route to strain hardening N2 - In order to investigate their microcracking behaviour, the microstructures of several β-eucryptite ceramics, obtained from glass precursor and cerammed to yield different grain sizes and microcrack densities, were characterized by laboratory and synchrotron x-ray refraction and tomography. Results were compared with those obtained from scanning electron microscopy (SEM). In SEM images, the characterized materials appeared fully dense but computed tomography showed the presence of pore clusters. Uniaxial tensile testing was performed on specimens while strain maps were recorded and analyzed by Digital Image Correlation (DIC). X-ray refraction techniques were applied on specimens before and after tensile testing to measure the amount of the internal specific surface (i.e., area per unit volume). X-ray refraction revealed that (a) the small grain size (SGS) material contained a large specific surface, originating from the grain boundaries and the interfaces of TiO2 precipitates; (b) the medium (MGS) and large grain size (LGS) materials possessed higher amounts of specific surface compared to SGS material due to microcracks, which decreased after tensile loading; (c) the precursor glass had negligible internal surface. The unexpected decrease in the internal surface of MGS and LGS after tensile testing is explained by the presence of compressive regions in the DIC strain maps and further by theoretical arguments. It is suggested that while some microcracks merge via propagation, more close mechanically, thereby explaining the observed X-ray refraction results. The mechanisms proposed would allow the development of a strain hardening route in ceramics. KW - Beta-eucryptite KW - Microcracked ceramics KW - X-ray refraction KW - Tensile load KW - Strain hardening KW - Synchrotron KW - BAMline KW - Computed Tomography KW - CT PY - 2018 UR - http://www.sciencedirect.com/science/article/pii/S1359645417308881 DO - https://doi.org/10.1016/j.actamat.2017.10.030 SN - 1359-6454 SN - 1873-2453 VL - 144 IS - Supplement C SP - 627 EP - 641 PB - Elsevier B.V. AN - OPUS4-43024 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Erdmann, Maren A1 - Kupsch, Andreas A1 - Müller, Bernd R. A1 - Hentschel, Manfred P. A1 - Niebergall, Ute A1 - Böhning, Martin A1 - Bruno, Giovanni ED - Erdmann, Maren T1 - Diesel-induced transparency of plastically deformed high-density polyethylene N2 - High-density polyethylene becomes optically transparent during tensile drawing when previously saturated with diesel fuel. This unusual phenomenon is investigated as it might allow conclusions with respect to the material behavior. Microscopy, differential scanning calorimetry, density measurements are applied together with two scanning X-ray scattering techniques: wide angle X-ray scattering (WAXS) and X-ray refraction, able to extract the spatially resolved crystal orientation and internal surface, respectively. The sorbed diesel softens the material and significantly alters the yielding characteristics. Although the crystallinity among stretched regions is similar, a virgin reference sample exhibits strain whitening during stretching, while the diesel-saturated sample becomes transparent. The WAXS results reveal a pronounced fiber texture in the tensile direction in the stretched region and an isotropic orientation in the unstretched region. This texture implies the formation of fibrils in the stretched region, while spherulites remain intact in the unstretched parts of the specimens. X-ray refraction reveals a preferred orientation of internal surfaces along the tensile direction in the stretched region of virgin samples, while the sample stretched in the diesel-saturated state shows no internal surfaces at all. Besides from stretching saturated samples, optical transparency is also obtained from sorbing samples in diesel after stretching. KW - PE-HD Sorption KW - Cavitation KW - Diesel Fuel KW - X-ray refraction KW - WAXS KW - Internal Surfaces KW - Crystal Texture PY - 2019 DO - https://doi.org/10.1007/s10853-019-03700-8 SN - 1573-4803 SN - 0022-2461 VL - 54 IS - 17 SP - 11739 EP - 11755 PB - Springer US CY - US AN - OPUS4-48226 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Onel, Yener A1 - Wolk, Thomas A1 - Staude, Andreas A1 - Ehrig, Karsten A1 - Müller, Bernd R. A1 - Bruno, Giovanni T1 - Evaluating porosity in cordierite diesel particulate filter materials, part 1 X-ray refraction N2 - Bi-continuous porous ceramics for filtration applications possess a particularly complicated microstructure, with porosity and solid matter being intermingled. Mechanical, thermal, and filtration properties can only be precisely estimated if the morphology of both solid matter and porosity can be quantitatively determined. Using x-ray absorption and refraction, we quantitatively evaluate porosity and pore orientation in cordierite diesel particulate filter ceramics. Porosity values turn out to agree with mercury intrusion measurements, while pore orientation factors agree with published crystallographic texture data. KW - Porous ceramics KW - Pore orientation KW - X-ray refraction KW - Synchrotron KW - Interface PY - 2013 DO - https://doi.org/10.4416/JCST2013-00021 SN - 2190-9385 VL - 4 IS - 4 SP - 169 EP - 176 PB - Göller CY - Baden-Baden AN - OPUS4-29939 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Jaenisch, Gerd-Rüdiger A1 - Kardjilov, N. A1 - Tötzke, C. A1 - Markötter, Henning A1 - Hilger, A. A1 - Manke, I. T1 - X-ray compton line scan tomography N2 - The potentials of incoherent X-ray scattering (Compton) computed tomography (CT) are investigated. The imaging of materials of very different atomic number or density at once is generally a perpetual challenge for X-ray tomography or radiography. In a basic laboratory set-up for simultaneous perpendicular Compton scattering and direct beam attenuation tomography are conducted by single channel photon counting line scans. This results in asymmetric distortions of the projection profiles of the scattering CT data set. In a first approach, corrections of Compton scattering data by taking advantage of rotational symmetry yield tomograms without major geometric artefacts. A cylindrical sample composed of PE, PA, PVC, glass and wood demonstrates similar Compton contrast for all the substances, while the conventional absorption tomogram only reveals the two high order materials. Comparison to neutron tomography reveals astonishing similarities except for the glass component (without hydrogen). Therefore, Compton CT offers the potential to replace neutron tomography, which requires much more efforts. KW - X-ray compton scattering KW - Computed tomography KW - Neutron tomography PY - 2015 DO - https://doi.org/10.3139/120.110799 SN - 0025-5300 VL - 57 IS - 11-12 SP - 985 EP - 991 PB - Hanser CY - München AN - OPUS4-34963 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kupsch, Andreas A1 - Hentschel, Manfred P. A1 - Lange, Axel A1 - Bruno, Giovanni A1 - Müller, Bernd R. T1 - Direct X-ray refraction of micro structures N2 - For the first time we present direct 2D imaging of refracted X-rays without any discrimination of the Primary radiation. X-refraction works in analogy to visible light optics: X-rays are entirely deflected at interfaces where discontinuities of (electron) density occur. This is demonstrated at the example of inner and outer surfaces of model samples of well-defined geometry (fibres, capillaries, and monodisperse micro particles). The samples are scanned through a 50 μm monochromatic (20 keV) pencil beam. In order to warrant a sufficient angular resolution a 2D detector (pixel size 7 μm) is placed 3 m downstream of the sample. Scanning the sample in micron steps allows for detecting local changes of interface / surface orientation directly in two dimensions. At the actual angular resolution of about 3 seconds of arc (scattering vector increments Δk = 10-3 nm-1) and 50 μm spatial resolution (scanning) the material’s inner surfaces (with nanometer separation) can be characterized even at sampling rates below 1 second per frame. Moreover, our technique is suited to directly determine particle diameters of up to 250 nm by means of diffraction fringes. Some potential applications to technical submicron structures are discussed. T2 - ECNDT 2014 - 11th European conference on non-destructive testing CY - Prague, Czech Republic DA - 06.10.2014 KW - X-ray refraction KW - Phase contrast KW - Edge artefact KW - Soft matter radiography KW - Wavelet transformation KW - Huygens elementary waves PY - 2014 SN - 978-80-214-5018-9 SP - 1 EP - 9 AN - OPUS4-31970 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Tötzke, C. A1 - Gaiselmann, G. A1 - Osenberg, M. A1 - Bohner, J. A1 - Arlt, Tobias A1 - Markötter, Henning A1 - Hilger, A. A1 - Wieder, F. A1 - Kupsch, Andreas A1 - Müller, Bernd R. A1 - Hentschel, Manfred P. A1 - Banhart, J. A1 - Schmidt, V. A1 - Lehnert, W. A1 - Manke, I. T1 - Three-dimensional study of compressed gas diffusion layers using synchrotron X-ray imaging N2 - We present a synchrotron X-ray tomographic study on the morphology of carbon fiber-based gas diffusion layer (GDL) material under compression. A dedicated compression device is used to provide well-defined compression conditions. A flat compression punch is employed to study the fiber geometry at different degrees of compression. Transport relevant geometrical parameters such as porosity, pore size and tortuosity distributions are calculated. The geometric properties notably change upon compression which has direct impact on transport conditions for gas and fluid flow. The availability of broad 3D paths, which are most important for the transport of liquid water from the catalyst layer through the GDL, is markedly reduced after compression. In a second experiment, we study the influence of the channel-land-pattern of the flow-field on shape and microstructure of the GDL. A flow-field compression punch is employed to reproduce the inhomogeneous compression conditions found during fuel cell assembly. While homogenously compressed underneath the land the GDL is much less and inhomogeneously compressed under the channel. The GDL material extends far into the channel volume where it can considerably influence gas and fluid flow. Loose fiber endings penetrate deeply into the channel and form obstacles for the discharge of liquid water droplets. KW - Synchrotron X-ray tomography KW - Gas diffusion layer (GDL) KW - Microstructure KW - Water transport path KW - Pore size analysis KW - Geometrical tortuosity PY - 2014 DO - https://doi.org/10.1016/j.jpowsour.2013.12.062 SN - 0378-7753 VL - 253 SP - 123 EP - 131 PB - Elsevier CY - Amsterdam [u.a.] AN - OPUS4-29979 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bruno, Giovanni A1 - Staude, Andreas A1 - Meinel, Dietmar A1 - Hentschel, Manfred P. A1 - Müller, Bernd R. ED - Grellmann, W. ED - Frenz, H. T1 - Moderne bildgebende hochauflösende Röntgenverfahren für die Materialcharakterisierung N2 - Die Computertomographie (CT) ist in der Medizin als Standardtechnik etabliert, in der zerstörungsfreien Prüfung wird sie zunehmend angewendet, in einzelnen Fällen sogar als Referenzverfahren eingesetzt. Gegenwärtig ist eine starke Zunahme von Anwendungen der CT in der Materialcharakterisierung zu verzeichnen. Zudem werden weitere moderne 3D-Techniken für werkstoffwissenschaftliche Fragestellungen genutzt, um die Mikrostruktur - auch in situ (z.B. Druck, Temperatur) - aufzuklären. Hier werden neben der konventionellen Absorptions-CT auch die Potenziale der Refraktions-CT zur Beantwortung prozesstechnischer sowie werkstofflicher Fragestellungen aufgezeigt, die ein „ganzheitliches Bild“ des jeweiligen Werkstoffs zum Ziel haben. T2 - Tagung Werkstoffprüfung 2014 - Fortschritte in der Werkstoffprüfung für Forschung und Praxis - Werkstoffeinsatz, Qualitätssicherung und Schadensanalyse CY - Berlin, Germany DA - 04.12.2014 KW - Computer tomography KW - X-ray refraction KW - Ceramics KW - Concrete KW - Inhomogeneous materials KW - Computertomographie KW - Röntgenrefraktion KW - Keramik KW - Beton KW - Mehrphasige Materialien PY - 2014 SN - 978-3-9814516-8-9 SN - 1861-8154 SP - 1 EP - 12 AN - OPUS4-32565 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Onel, Yener A1 - Lange, Axel A1 - Staude, Andreas A1 - Ehrig, Karsten A1 - Kupsch, Andreas A1 - Hentschel, Manfred P. A1 - Wolk, Thomas A1 - Müller, Bernd R. A1 - Bruno, Giovanni T1 - Evaluating porosity in cordierite Diesel particulate filter materials, Part 2 statistical analysis of computed tomography data N2 - Complementary to Part 1 of this work, the bi-continuous microstructure of porous synthetic cordierite ceramics for filtration applications was investigated using 3D x-ray computed tomography at different resolutions. Applying both Fast Fourier Transform and a newly developed image analysis algorithm, we quantitatively evaluated porosity and pore orientation. The statistical approach allows extraction of spatially resolved or average values. Porosity values based on x-ray absorption agree with mercury intrusion measurements, while pore orientation factors agree with x-ray refraction data (Part 1 of this work), and with published crystallographic texture data. KW - Pore orientation KW - Porous ceramics KW - Computed tomography KW - 3D microstructure PY - 2013 DO - https://doi.org/10.4416/JCST2013-00022 SN - 2190-9385 VL - 05 IS - 01 SP - 13 EP - 22 PB - Göller CY - Baden-Baden AN - OPUS4-30379 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Kupsch, Andreas A1 - Jaenisch, Gerd-Rüdiger A1 - Kardjilov, N. A1 - Tötzke, C. A1 - Markötter, Henning A1 - Hilger, A. A1 - Manke, I. T1 - X-ray compton tomography N2 - The potentials of incoherent X-ray Scattering (Compton) tomography are investigated. Imaging materials of very different density or atomic number at once is a perpetual challenge for X-ray tomography or radiography, in general. In a basic laboratory set-up for simultaneous perpendicular Compton Scattering and direct beam attenuation tomographic scans are conducted by single channel photon counting. This results in asymmetric distortions of the projection profiles of the scattering CT-data set. ln a first approach corrections of Compton scattering data by taking advantage of rotational symmetry yield tomograms without major geometric artefacts. A cylindrical sample composed of PE, PA, PVC, glass and wood demonstrates similar Compton contrast for all the substances, while the conventional absorption tomogram only reveals the two high order materials. Compärison to neutron tomography reveals astonishing similarities except for the glass component (without hydrogen). Therefore, Compton CT bears the potential to replace neutron tomography, which requires much more efforts. T2 - ECNDT 2014 - 11th European Conference on Non-Destructive Testing CY - Prague, Czech Republic DA - 06.10.2014 KW - X-ray compton scattering KW - Computed tomography KW - Neutron tomography PY - 2014 SN - 978-80-214-5018-9 SP - 1 EP - 9 PB - Brno University of Technology CY - Brno AN - OPUS4-31972 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Shashev, Yury A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Evsevleev, Sergei A1 - Müller, Bernd R. A1 - Osenberg, Markus A1 - Manke, Ingo A1 - Hentschel, Manfred P. A1 - Bruno, Giovanni T1 - Optimizing the visibility of X-ray phase grating interferometry N2 - The performance of grating interferometers coming up now for Imaging interfaces within materials depends on the efficiency (visibility) of their main component, namely the phase grating. Therefore, experiments with monochromatic synchrotron radiation and corresponding simulations are carried out. The visibility of a Phase grating is optimized by different photon energies, varying detector to grating distances and continuous rotation of the phase grating about the grid lines. Such kind of rotation changes the projected grating shapes, and thereby the distribution profiles of phase shifts. This yields higher visibilities than derived from ideal rectangular shapes. By continuous grating rotation and variation of the propagation distance, we achieve 2D visibility maps. Such maps provide the visibility for a certain combination of grating orientation and detector position. Optimum visibilities occur at considerably smaller distances than in the standard setup. KW - Synchrotron, BAMline KW - Talbot-Lau interferometer KW - X-ray imaging KW - X-ray refraction KW - Grating interferometry KW - X-ray phase contrast PY - 2017 DO - https://doi.org/10.3139/120.111097 SN - 0025-5300 VL - 59 IS - 11-12 SP - 974 EP - 980 PB - Hanser Verlag AN - OPUS4-42955 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Onel, Yener A1 - Wolk, Thomas A1 - Staude, Andreas A1 - Ehrig, Karsten A1 - Müller, Bernd R. A1 - Bruno, Giovanni T1 - Evaluating porosity in cordierite diesel particulate filter materials: advanced X-ray techniques and new statistical analysis methods N2 - Bi-continuous porous ceramics for filtration applications possess a particularly complicated microstructure, whereby porosity and solid matter are intermingled. Mechanical, thermal, and filtration properties can only be precisely estimated if the morphology of both solid matter and porosity can be quantitatively determined. Using 3D computed tomography (CT) at different resolutions, and several X-ray refraction-based techniques, we quantitatively evaluated porosity and pore orientation in cordierite diesel particulate filter ceramics.Moreover, applying both Fast Fourier Transform (FFT) and a newly developed image analysis algorithm (directional interface variance analysis, DIVA), we quantitatively evaluated porosity and pore orientation. Both the experimental techniques and the statistical approach allow extraction of spatially resolved or average values.Porosity values from synchrotron computed tomography used turn out to agree with mercury intrusion measurements, while pore orientation factors agree with published crystallographic texture data. This latter point also implies that the study of the pore/matter interface is sufficient to describe the morphological properties of these materials. KW - Diesel particulate filters KW - DIVA Algorithm KW - Pore Orientation KW - Porous Ceramics KW - X-Ray Computed Tomography KW - X-Ray Refraction PY - 2014 DO - https://doi.org/10.4028/www.scientific.net/AST.91.64 SN - 1662-0356 VL - 91 SP - 64 EP - 69 PB - Techna CY - Faenza AN - OPUS4-32069 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Bruno, Giovanni A1 - Onel, Yener A1 - Wolk, Thomas A1 - Staude, Andreas A1 - Ehrig, Karsten A1 - Müller, Bernd R. T1 - Evaluating porosity in cordierite diesel particulate filter materials: advanced X-ray techniques and new statistical analysis methods T2 - ECNDT 2014 - 11th European conference on non-destructive testing CY - Prague, Czech Republic DA - 2014-10-06 KW - Porous ceramics KW - Diesel particulate filters KW - Pore orientation KW - X-ray computed tomography KW - X-ray refraction KW - DIVA algorithm KW - Phase contrast KW - Edge artefact KW - Soft matter radiography KW - Wavelet transform KW - Huygens elementary waves PY - 2014 SN - 978-80-214-5018-9 SP - 1 EP - 8(?) AN - OPUS4-31973 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bruno, Giovanni A1 - Ehrig, Karsten A1 - Haarring, Holger A1 - Harwardt, Michael A1 - Hentschel, Manfred P. A1 - Illerhaus, Bernhard A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Meinel, Dietmar A1 - Müller, Bernd R. A1 - Onel, Yener A1 - Staude, Andreas A1 - Wolk, Thomas T1 - Industrial and synchrotron X-ray CT applications for materials characterisation N2 - The combination of tomographic, microstructural data with other experimental techniques and with modeling is paramount, if we want to extract the maximum amount of information on material and component properties. In particular, quantitative image analysis, statistical approaches, direct discretization of tomographic reconstructions represent concrete possibilities to extend the power of the tomographic 3D representation to insights into the material and component performance. This logic thread holds equally for industrial and academic research, and valorizes expensive experiments such as those carried out at synchrotron sources, which cannot be daily repeated. We shall show a few examples of possible use of X-ray tomographic data for quantitative assessment of damage evolution and microstructural properties, as well as for non-destructive testing. We will also show how X-ray refraction computed tomography (CT) can be highly complementary to classic absorption CT, being sensitive to internal interfaces. T2 - iCT Conference 2014 - Conference on industrial computed tomography CY - Wels, Austria DA - 25.02.2014 KW - X-ray absorption and refraction CT KW - Quantitative image analysis KW - Statistical analysis KW - Complex microstructure PY - 2014 SN - 978-3-8440-2557-6 SP - 15 EP - 31 PB - Shaker CY - Aachen AN - OPUS4-30484 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, Bernd R. A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Kupsch, Andreas T1 - Numerische Korrektur des Hinterleuchtens von Röntgendetektoren N2 - Eine neuartige Korrektur artefaktisch gemessener Intensitäten von Röntgenflachdetektoren wird vorgeschlagen. Die betrachteten Artefakte betreffen eine diffuse Umverteilung der Intensität und führen zu beträchtlichen Verfälschungen der wahren Schwächung und verletzen mithin das Lambert-Beer'sche Gesetz. Sie werden sowohl in Laborexperimenten mit Röntgenröhren (polychromatische Einstrahlung) als auch mit monochromatischer Synchrotronstrahlung bei Einsatz indirekt konvertierender Detektionssysteme (Fluoreszenzschirm, Optik, CCD-Chip) beobachtet. Dieser Effekt wird als Hinterleuchten bezeichnet. In der vorgestellten Studie werden mittels wohldefinierter Randbedingungen Gesetzmäßigkeiten des Hinterleuchtens untersucht: durch Einsatz monochromatischer Strahlung können Aufhärtungseffekte als Ursache ausgeschlossen werden. Das Hinterleuchten ist umso stärker ausgeprägt, je weniger Detektorfläche vom Objekt abdeckt wird und je stärker das Objekt schwächt. Mit Blick auf Tomographien ergibt sich eine Modulation der 'Dichte' als Funktion des Projektionswinkels, deren Amplitude mit dem Objektumfang steigt (Dynamik). Der isotrope und homogene Ansatz zur numerischen Korrektur macht lediglich Gebrauch von Intensitätsmittelwerten und stellt die Gültigkeit des Schwächungsgesetzes in modifizierter Form wieder her. T2 - DACH-Jahrestagung 2012 CY - Graz, Austria DA - 17.09.2012 KW - Röntgendetektor KW - Hinterleuchten PY - 2012 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-277372 SN - 978-3-940283-44-3 IS - DGZfP-BB 136 SP - P 13 / Mo.4.B, 1 EP - 7 AN - OPUS4-27737 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -