TY - JOUR A1 - Rodrigues, J.P.C. A1 - LaĆ­m, L.M. A1 - Korzen, Manfred T1 - Fire behaviour of circular concrete columns with restrained thermal elongation N2 - Most of the previous studies on reinforced concrete columns with elastically restrained thermal elongation were carried out on square, rectangular or '+'-shaped cross sections. The number of fire resistance tests on circular reinforced concrete columns with elastically restrained thermal elongation is still very small. In order to examine the influence of several parameters on the behaviour in fire of this type of columns several fire resistance tests were carried out. The parameters tested were the load and restraint level, slenderness of the column and longitudinal reinforcement ratio. In the fire resistance tests the specimens were exposed to the ISO 834 standard fire curve and the critical time (fire resistance) and temperature and failure modes were determined. The test results showed that the spalling phenomenon may occur in circular columns and so reducing its fire resistance. The increasing of the load level led to a reduction while the increasing of the longitudinal reinforcement ratio or the decreasing of the slenderness of the columns led to an increasing of their fire resistance. The restraint level might not be much relevant on the fire resistance of circular reinforced concrete columns. KW - Fire KW - Resistance KW - Concrete KW - Circular KW - Column KW - Restraining PY - 2014 U6 - https://doi.org/10.3151/jact.12.289 SN - 1346-8014 VL - 12 IS - 9 SP - 289 EP - 298 CY - Tokyo AN - OPUS4-31611 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -