TY - JOUR A1 - Adams, L. C. A1 - Brangsch, J. A1 - Reimann, C. A1 - Kaufmann, Jan Ole A1 - Nowak, K. A1 - Buchholz, R. A1 - Karst, U. A1 - Botnar, R. M. A1 - Hamm, B. A1 - Makowski, M. R. T1 - Noninvasive imaging of vascular permeability to predict the risk of rupture in abdominal aortic aneurysms using an albumin binding probe JF - Scientific Reports N2 - Abdominal aortic aneurysm (AAA) remains a fatal disease. Its development encompasses a complex interplay between hemodynamic stimuli on and changes in the arterial wall. Currently available biomarkers fail to predict the risk of AAA rupture independent of aneurysm size. Therefore, novel biomarkers for AAA characterization are needed. In this study, we used a mouse model of AAA to investigate the potential of magnetic resonance imaging (MRI) with an albumin-binding probe to assess changes in vascular permeability at different stages of aneurysm growth. Two imaging studies were performed: a longitudinal study with follow-up and death as endpoint to predict rupture risk and a week-by-week study to characterize AAA development. AAAs, which eventually ruptured, demonstrated a significantly higher in vivo MR signal enhancement from the albumin-binding probe (p = 0.047) and a smaller non-enhancing thrombus area compared to intact AAAs (p = 0.001). The ratio of albumin-binding-probe enhancement of the aneurysm wall to size of non-enhancing-thrombus-area predicted AAA rupture with high sensitivity/specificity (100%/86%). More advanced aneurysms with higher vascular permeability demonstrated an increased uptake of the albumin-binding-probe. These results indicate that MRI with an albumin-binding probe may enable noninvasive assessment of vascular permeability in murine AAAs and prediction of rupture risk. KW - Magnetic resonance imaging KW - Imaging KW - Tomography KW - Gadolinium KW - Contrast agent KW - Atherosclerosis KW - ICP-MS KW - Gadofosveset KW - Angiography KW - LA-ICP-MS PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-525541 DO - https://doi.org/10.1038/s41598-020-59842-2 VL - 10 SP - Article number: 3231 PB - Springer Nature Limited CY - London, New York, Berlin, Shanghai and Tokyo AN - OPUS4-52554 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wiedensohler, A. A1 - Wiesner, A. A1 - Weinhold, K. A1 - Birmili, W. A1 - Herrmann, M. A1 - Merkel, M. A1 - Müller, T. A1 - Pfeifer, S. A1 - Schmidt, A. A1 - Tuch, T. A1 - Velarde, F. A1 - Quincey, P. A1 - Seeger, Stefan A1 - Nowak, A. T1 - Mobility particle size spectrometers: Calibration procedures and measurement uncertainties JF - Aerosol Science and Technology N2 - Mobility particle size spectrometers (MPSS) belong to the essential instruments in aerosol science that determine the particle number size distribution (PNSD)in the submicrometer size range. Following calibration procedures and target uncertainties against standards and reference instruments are suggested for a complete MPSS quality assurance program: a) calibration of the CPC counting efficiency curve (within 5% for the plateau counting efficiency; within 1 nm for the 50% detection efficiency diameter), b) sizing calibration of the MPSS, using a certified polystyrene latex (PSL) particle size standard at 203 nm (within 3%), c) intercomparison of the PNSD of the MPSS (within 10% and 20% of the dN/dlogDP concentration for the particle size range 20 – 200 nm and 200 to 800 nm, respectively), and d) intercomparison of the integral PNC of the MPSS (within 10%). Furthermore, following measurement uncertainties have been investigated: a) PSL particle size standards in the range from 100-500nm match within 1% after sizing calibration at 203 nm. b) Bipolar diffusion chargers based on the radioactive nuclides Kr85, Am241 and Ni63 and a new ionizer based on corona discharge follow the recommended bipolar charge distribution, while soft X-ray-based charges may alter faster than expected. c) The use of a positive high voltage supply show a 10% better performance than a negative one. d) The intercomparison of the integral PNC of an MPSS against the total number concentration is still within the target uncertainty at an ambient pressure of approximately 500 hPa. KW - Measurement uncertainties KW - Mobility particle size spectrometer (MPPS) KW - Condensation particle counter (CPC) KW - Calibration PY - 2017 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-425060 DO - https://doi.org/10.1080/02786826.2017.1387229 SN - 1521-7388 VL - 52 IS - 2 SP - 146 EP - 164 PB - Tailor & Francis CY - USA AN - OPUS4-42506 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schneider, Ronald A1 - Fischer, J. A1 - Bügler, M. A1 - Nowak, M. A1 - Thöns, S. A1 - Borrmann, A. A1 - Straub, D. T1 - Assessing and updating the reliability of concrete bridges subjected to spatial deterioration - principles and software implementation JF - Structural concrete N2 - Inspection and maintenance of concrete bridges is a major cost factor in transportation infrastructure, and there is significant potential for using information gained during inspection to update predictive models of the performance and reliability of such structures. In this context, this paper presents an approach for assessing and updating the reliability of prestressed concrete bridges subjected to chloride-induced reinforcement corrosion. The system deterioration state is determined based on a Dynamic Bayesian Network (DBN) model that considers the spatial variability of the corrosion process. The overall system reliability is computed by means of a probabilistic structural model coupled with the deterioration model. Inspection data are included in the system reliability calculation through Bayesian updating on the basis of the DBN model. As proof of concept, a software prototype is developed to implement the method presented here. The software prototype is applied to a typical highway bridge and the influence of inspection information on the system deterioration state and the structural reliability is quantified taking into account the spatial correlation of the corrosion process. This work is a step towards developing a software tool that can be used by engineering practitioners to perform reliability assessments of ageing concrete bridges and update their reliability with inspection and monitoring data. KW - Structural reliability KW - Dynamic Bayesian Networks KW - Spatial deterioration KW - Inspection KW - Monitoring general KW - Analysis and design methods KW - Reinforcement KW - Corrosion KW - Prestressed concrete PY - 2015 DO - https://doi.org/10.1002/suco.201500014 SN - 1464-4177 VL - 16 IS - 3 SP - 356 EP - 365 PB - Ernst & Sohn CY - Berlin AN - OPUS4-34336 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Nowak, S.H. A1 - Bjeoumikhov, A. A1 - Von Borany, J. A1 - Buchriegler, J. A1 - Munnik, F. A1 - Petric, M. A1 - Renno, A.D. A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Scharf, O. A1 - Strüder, L. A1 - Wedell, R. A1 - Ziegenrücker, R. T1 - Examples of XRF and PIXE imaging with few microns resolution using SLcam® a color X-ray camera JF - X-ray spectrometry N2 - We present results of recent development of the color X-ray camera, type SLcam®, allowing detection of X-ray images with few microns resolution. Such spectral resolution is achieved with the use of high-quality polycapillary optics combined with sub-pixel resolution. Imaging of Siemens star resolution test chart reveals that the resolution limit of SLcam® can go down to nearly 5µm. Several real sample examples of measurements carried out at the laboratory, synchrotron, and particle-induced X-ray emission beamlines are shown. This is the first time SLcam® is used as particle-induced X-ray emission detector. KW - X-ray KW - Color X-ray camera KW - CXC KW - Synchrotron radiation KW - BESSY KW - BAMline PY - 2015 DO - https://doi.org/10.1002/xrs.2590 SN - 0049-8246 VL - 44 IS - 3 SP - 135 EP - 140 PB - Wiley & Sons, Ltd. CY - Chichester AN - OPUS4-33170 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Nowak, S.H. A1 - Bjeoumikhov, A. A1 - Von Borany, J. A1 - Buchriegler, J. A1 - Munnik, F. A1 - Petric, M. A1 - Radtke, Martin A1 - Renno, A.D. A1 - Reinholz, Uwe A1 - Scharf, O. A1 - Wedell, R. T1 - Sub-pixel resolution with a color X-ray camera JF - Journal of analytical atomic spectrometry N2 - The color X-ray camera SLcam® is a full-field, single photon detector providing scanning-free, energy and spatially resolved X-ray imaging. Spatial resolution is achieved with the use of polycapillary optics guiding X-ray photons from small regions on a sample to distinct energy dispersive pixels on a charged-coupled device detector. Applying sub-pixel resolution, signals from individual capillary channels can be distinguished. Therefore, the SLcam® spatial resolution, which is normally limited to the pixel size of the charge-coupled device, can be improved to the size of individual polycapillary channels. In this work a new approach to a sub-pixel resolution algorithm comprising photon events also from the pixel centers is proposed. The details of the employed numerical method and several sub-pixel resolution examples are presented and discussed. KW - Color X-ray camera KW - Sub pixel analysis PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-334948 DO - https://doi.org/10.1039/c5ja00028a SN - 0267-9477 SN - 1364-5544 SP - 1890 EP - 1897 PB - Royal Society of Chemistry CY - London AN - OPUS4-33494 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Nowak, S. H. A1 - Petric, M. A1 - Buchriegler, J. A1 - Bjeoumikhov, A. A1 - Bjeoumikhova, Z. A1 - von Borany, J. A1 - Munnik, F. A1 - Radtke, Martin A1 - Renno, A. D. A1 - Reinholz, Uwe A1 - Scharf, O. A1 - Tilgner, J. A1 - Wedell, R. T1 - Road to micron resolution with a color X-ray camera – polycapillary optics characterization T2 - arXiv.org N2 - In a color X-ray camera spatial resolution is achieved by means of a polycapillary optic conducting X-ray photons from small regions on a sample to distinct energy dispersive pixels on a CCD matrix. At present, the resolution limit of color X-ray camera systems can go down to several microns and is mainly restricted by Pixel dimensions. The recent development of an efficient subpixel resolution algorithm allows a release from pixel size, limiting the resolution only to the quality of theoptics. In this work polycapillary properties that influence the spatial resolution are systematized and assessed both theoretically and experimentally. It is demonstrated that with the current technological Level reaching one micron resolution is challenging, but possible. KW - Color X-ray camera KW - Polycapillary optics PY - 2017 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-404404 UR - https://arxiv.org/abs/1705.08939 SN - 2331-8422 SP - 1 EP - 11 PB - Cornell University CY - Ithaca, NY AN - OPUS4-40440 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Herbig, B. A1 - Jörres, R. A. A1 - Schierl, R. A1 - Simon, M. A1 - Langner, Jeanette A1 - Seeger, Stefan A1 - Nowak, D. A1 - Karrasch, S. T1 - Psychological and cognitive effects of laser printer emissions: A controlled exposure study JF - Indoor Air N2 - The possible impact of ultrafine particles from laser printers on human health is controversially discussed although there are persons reporting substantial symptoms in relation to these emissions. A randomized, single-blinded, cross-over experimental design with two exposure conditions (high-level and low-level exposure) was conducted with 23 healthy subjects, 14 subjects with mild asthma, and 15 persons reporting symptoms associated with laser printer emissions. To separate physiological and psychological effects, a secondary physiologically based categorization of susceptibility to particle effects was used. In line with results from physiological and biochemical assessments, we found no coherent, differential, or clinically relevant effects of different exposure conditions on subjective complaints and cognitive performance in terms of attention, short-term memory, and psychomotor performance. However, results regarding the psychological characteristics of participants and their situational perception confirm differences between the participants groups: Subjects reporting symptoms associated with laser printer emissions showed a higher psychological susceptibility for adverse reactions in line with previous results on persons with multiple chemical sensitivity or idiopathic environmental intolerance. In conclusion, acute psychological and cognitive effects of laser printer emissions were small and could be attributed only to different participant groups but not to differences in exposure conditions in terms of particle number concentrations. KW - Cognitive performance KW - Exposure KW - Idiopathic environmental intolerance KW - Laser printer emission KW - Multiple chemical sensitivity KW - Subjective complaints PY - 2018 DO - https://doi.org/10.1111/ina.12429 SN - 1600-0668 SN - 0905-6947 VL - 28 IS - 1 SP - 112 EP - 124 PB - John Wiley & Sons, Inc. CY - 111 RIVER ST, HOBOKEN 07030-5774, NJ USA AN - OPUS4-43945 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Karrasch, Stefan A1 - Simon, M. A1 - Herbig, Britta A1 - Langner, Jeanette A1 - Seeger, Stefan A1 - Kronseder, A. A1 - Peters, S. A1 - Dietrich-Gümperlein, G. A1 - Schierl, R. A1 - Nowak, D. A1 - Jörres, R.A. ED - Nazaroff, William T1 - Health effects of laser printer emissions: a controlled exposure study JF - Indoor Air N2 - Ultrafine particles emitted from laser printers are suspected to elicit adverse health effects. We performed 75-minute exposures to emissions of laser printing devices (LPDs) in a standardized, randomized, cross- over manner in 23 healthy subjects, 14 mild, stable asthmatics, and 15 persons reporting symptoms associated with LPD emissions. Low-level exposures (LLE) ranged at the particle background (3000 cm−3) and High-level exposures (HLE) at 100 000 cm−3. Examinations before and after exp sures included spirometry, body plethysmography, transfer factors for CO and NO (TLCO, TLNO), bronchial and alveolar NO, cytokines in serum and nasal secretions (IL-1β, IL-5, IL-6, IL-8, GM-CSF, IFNγ, TNFα), serum ECP, and IgE. Across all participants, no statistically significant changes occurred for lung mechanics and NO. There was a decrease in volume-related TLNO that was more pronounced in HLE, but the difference to LLE was not significant. ECP and IgE increased in the same way after exposures. Nasal IL-6 showed a higher increase after LLE. There was no coherent pattern regarding the responses in the participant subgroups or single sets of variables. In conclusion, the experimental acute responses to short but very high-level LPD exposures were small and did not indicate clinically relevant effects compared to low particle number concentrations. KW - Emission KW - Exposure KW - Laser printer KW - Lung function KW - Respiratory health KW - Ultrafine particles PY - 2017 DO - https://doi.org/10.1111/ina.12366 SN - 1600-0668 VL - 27 IS - 4 SP - 753 EP - 765 PB - John Wiley & Sons Ltd. CY - London AN - OPUS4-42593 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Karrasch, S. A1 - Jörres, R. A1 - Ehret, M. A1 - Herbig, B. A1 - Schierl, R. A1 - Seeger, Stefan A1 - Langner, J. A1 - Nowak, D. ED - Hildenbrandt, Sibylle ED - Rieger, Monika A. T1 - Untersuchung möglicher gesundheitlicher Gefährdungen durch Drucker- und Kopierer-Emissionen Teil 1 und 2 T2 - Dokumentation der 55. Jahrestagung der DGAUM 2015 N2 - Teil 1: In der Öffentlichkeit werden immer wieder mögliche gesundheitliche Auswirkungen von Laserdruckeremissionen diskutiert. Um diese möglichen Auswirkungen genauer zu analysieren, wurden die Effekte 75-minütiger Expositionen von sogenannten Low-Emittern (LE, Untergrund 2000-4000 UFP/cm3) gegenüber High-Emittern (HE, 100.000 UFP/cm3) untersucht. Teil 2: Mögliche gesundheitliche Auswirkungen von Laserdruckeremissionen sind immer wieder Gegenstand öffentlicher Aufmerksamkeit. Die dabei auftretenden potenziellen psychologischen Aspekte, wurden in einem standardisierten Szenario mittels 75-minütiger Expositionen gegenüber Low-Emittern (LE, Untergrund 2000-4000 UFP/cm3) und High-Emittern (HE, 100.000 UFP/cm3) untersucht. T2 - 55. Jahrestagung der DGAUM 2015 CY - Munich, Germany DA - 18.03.2015 KW - Gesundheitsgefährdung KW - Laserdrucker KW - Bürogeräte KW - Partikel KW - Emissionen PY - 2015 SN - 978-3-9817007-1-8 SP - 357 EP - 489 PB - Geschäftsstelle der Deutschen Gesellschaft für Arbeitsmedizin und Umweltmedizin e. V. CY - München AN - OPUS4-38751 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Seeger, Stefan A1 - Langner, Jeanette A1 - Nowak, D. A1 - Jörres, R.A. A1 - Karrasch, S. A1 - Ehret, M. A1 - Herbig, B. A1 - Schierl, R. T1 - Untersuchung möglicher gesundheitlicher Gefährdungen durch Drucker- und Kopierer-Emissionen KW - Bürogeräte KW - Laserdrucker KW - Partikelemission KW - Aerosol KW - Gesundheitliche Gefährdung KW - In-vivo-Studie PY - 2014 UR - http://www.dguv.de/Projektdatenbank/0294A/3228509v1.pdf SP - 1 EP - 238 CY - Berlin ET - Abschlussbericht der Projektpartner zum DGUV-Projekt (Kennziffer FP 294) AN - OPUS4-31335 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Jörres, R. A1 - Ehret, M. A1 - Karrasch, S. A1 - Herbig, B A1 - Schierl, R. A1 - Seeger, Stefan A1 - Langner, J. A1 - Nowak, D. T1 - Respiratorische Effekte von Drucker- und Kopierer-Emissionen – eine kontrollierte Expositionsstudie T2 - Pneumologie N2 - Die möglichen gesundheitlichen Auswirkungen von Laserdruckeremissionen sind immer wieder Gegenstand von Aufmerksamkeit. Wir untersuchten die Effekte 75-minütigerExpositionen gegenüber Low-Emittern (LE, Untergrund 2000 – 4000 UFP/cm3) und High-Emittern (HE, 100.000 UFP/cm3). T2 - 56. Kongress der Deutschen Gesellschaft für Pneumologie und Beatmungsmedizin e.V. CY - Berlin, Germany DA - 18.03.2015 KW - Expositionsstudie in-vivo KW - Bürogeräte KW - Emissionen KW - Partikel PY - 2015 DO - https://doi.org/10.1055/s-0035-1544873 VL - 69-V516 SP - V516 PB - Thieme CY - Stuttgart AN - OPUS4-38752 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -