TY - RPRT A1 - Müller, B. A1 - Panasková, J. A1 - Danielak, M. A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Müller, D. T1 - Sensory-based evaluation of building product emissions - Integration into the Blue Angel award criteria and assessment scheme of the Committee for Health Evaluation of Building Products (UBA-FB 001500 / Förder-Kennz. 370762300) N2 - Emissions from building products can considerably impair the quality of indoor air. The AgBB scheme is employed to evaluate the emissions of volatile organic compounds (VOC) from building products. The hygienic evaluation according to the AgBB scheme requires product-specific measuring procedures. These are available for a range of products. They have been validated in co-operation with several research and testing institutes and have been included in the criteria for awarding the Blue Angel ecolabel. The evaluation is, however, stricter and generally has lower limits. VOC emissions and odours can cause health problems so testing using sensors is an important element in the evaluation of building products and has – for reasons of precaution – been set down in the AgBB scheme. The main goal of the project was to derive a method of evaluation using sensors and limits for awarding the Blue Angel and for the AgBB scheme. Based on the research conducted (see Chapter 5 Results and Discussion), perceived intensity and hedonics were suggested as a suitable Evaluation method. The derivation of limits for the evaluation using sensors on the 28th day was effected in the present study through the additional questioning of the test subjects on the reasonability of a sample. For the Blue Angel, there could be different limits of perceived intensity and hedonics for each group of products. A preliminary suggestion for possible limits – for all product groups – is a perceived intensity of 7 pi (5 pi + 2 pi as confidence coefficient, Chapter 5.1.5) and -1 (0+/-0.8, rounded to -1) for the hedonic value. KW - Labelsysteme KW - VOC KW - Geruch KW - Geruchstest KW - Emissionsmessungen KW - Building product KW - Directive KW - Health care KW - Pollutant KW - Test method KW - Hydrocarbon KW - Testing using sensors KW - Emission KW - Emission test chamber KW - Odour KW - AgBB scheme KW - Health assessment KW - Assessment procedure KW - Volatile organic compounds KW - Very volatile organic compounds KW - VVOC KW - Semi volatile organic compounds KW - SVOC KW - Thermal desorption KW - GC/MS KW - GC-ODP KW - Odour standard of comparison KW - Floor coverings KW - Coverings KW - Blue Angel KW - Odour evaluation KW - Acceptability KW - Perceived intensity KW - Hedonic KW - Reasonability KW - Standardization KW - Environmental sign KW - Volatile emission KW - Product labelling PY - 2011 UR - http://www.umweltbundesamt.de/publikationen/sensory-based-evaluation-of-building-product SN - 1862-4804 IS - 61 SP - 1-133, Annex 1-109 PB - Umweltbundesamt CY - Dessau-Roßlau AN - OPUS4-25200 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Wiegner, Katharina A1 - Farke, M. A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Hahn, Oliver ED - Brozio, P. T1 - Schadstoffe im Museum richtig einschätzen N2 - Schadstoffe beschäftigen derzeit Museen weltweit Heute weiß man, dass diese auch aus Materialien, die für den Ausstellungsbau verwendet werden, austreten können, was eine Gefahr für Exponate darstellt. Ein neues Verfahren namens BEMMA bietet nun erstmalig die Möglichkeit, relativ schnell und effektiv eine problemorientierte Untersuchung und Bewertung mit belastbaren und reproduzierbaren Ergebnissen vorzunehmen. KW - Emissionsarme Vitrinen KW - Präventive Konservierung KW - VOC KW - BEMMA PY - 2011 SN - 978-3-7667-1962-1 SP - 127 EP - 131 PB - Callwey CY - München AN - OPUS4-25377 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wiegner, Katharina A1 - Hahn, Oliver A1 - Farke, M. A1 - Kalus, Sabine A1 - Horn, Wolfgang T1 - Determination of formic and acetic acids in air N2 - Formic and acetic acids are often responsible for damage of cultural objects, e. g. glass and metal corrosion or changing and fading of colours. Museums all around the world are equipped with different show cases. Display cases should protect cultural objects from dust as well as from mechanical damage. Several construction materials which are used for display cases, including wood, glue and coatings, are possible sources of very volatile organic compounds (VVOCs), volatile organic compounds (VOCs) and semi volatile organic compounds (SVOCs). These construction products can emit formic and acetic acids into the indoor or display case air. Modern display cases with small air change rates can cause higher concentrations of formic and acetic acids if any source is installed in the display case (Salthammer and Uhde, 2009). To minimize the risk of damage emissions from building products must be quantified. There is a need for a method for identification and quantification of acetic and formic acid. Some possibilities for the identification of acetic acid exist. The quantification of acetic acid for example after sampling on TENAX® or CARBOTRAP and thermal desorption-GC in accordance with ISO 16000-6 and ISO 16017-1 results in very low recovery rates. A new method should be stabile, robust, reproducible and comparable, with an easy local sampling and determination in laboratories. Miniaturised emission test chambers and model display cases were used to study the recovery rates. T2 - Indoor Air 2011, 12th International conference on indoor air quality and climate CY - Austin, TX, USA DA - 05.06.2011 KW - VOCs KW - Detection of formic and acetic acid KW - Quantification of formic and acetic acid KW - Air sampling PY - 2011 IS - Paper 768 SP - 1 EP - 2 AN - OPUS4-23876 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, B. A1 - Dahms, A. A1 - Jakob, B. A1 - Knudsen, H.N. A1 - Afshari, A. A1 - Wargocki, P. A1 - Olesen, B. A1 - Berglund, B. A1 - Ramalho, O. A1 - Häringer, D. A1 - Jann, Oliver A1 - Horn, Wolfgang A1 - Nesa, D. A1 - Loubet, F. A1 - Ruponen, M. T1 - Measuring perceived air quality and intensity by means of sensor systems, the European Project SysPAQ T2 - Healthy buildings 2009 - 9th International conference & exhibition CY - Syracuse, NY, USA DA - 2009-09-13 KW - Sensor systems KW - Perceived air quality KW - Perceived intensity PY - 2009 IS - Paper 326 SP - 1 EP - 4 CY - Syracuse, NY, USA AN - OPUS4-20106 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wiegner, Katharina A1 - Hahn, Oliver A1 - Horn, Wolfgang A1 - Farke, M. A1 - Kalus, Sabine A1 - Nohr, Michael A1 - Jann, Oliver T1 - Determination of formic and acetic acid emissions in indoor air or from building products N2 - Several construction and building materials, including wood, glue and coatings, are possible sources of very volatile organic compounds (VVOCs) and volatile organic compounds (VOCs) like formic and acetic acid. Due to very high air tightness and very low air exchange rates in new buildings concentrations of these harmful substances can increase considerably. To minimize the risk, emissions from building products should be identified and quantified. With the common standard method, this means Tenax® sampling followed by thermal desorption and GC-MS analysis, these acids could not be detected sufficiently. The aim oft this study is the comparison of two different methods for the determination of acetic and formic acid. The sampling of method one, which is usually used for identification and quantification of VOCs, is done in accordance with ISO 16000-6 and ISO 16017-1 on Carbotrap® 202 multi-bed thermal desorption tube by subsequent identification and quantification with GC-MS. Method two is based on sampling on 2,4-dinitrophenylhydrazine (DNPH) cartridges, derivatisation, elution, identification and quantification of the derivatives with LC-MS/MS (liquid chromatography – mass spectrometry/mass spectrometry). N2 - Viele Konstruktions- und Baumaterialien, wie Holz, Kleber und Anstriche, sind mögliche Quellen für leicht flüchtige organische Verbindungen (VVOC) und flüchtige organische Verbindungen (VOC), wie Ameisen- und Essigsäure. Bedingt durch die hohe Dichtigkeit und den damit verbundenen niedrigen Luftwechsel in neuen Gebäuden können die Konzentrationen dieser gesundheitsgefährdenden Substanzen beträchtlich ansteigen. Um das Risiko zu minimieren, sollen Emissionen aus Bauprodukten identifiziert und quantifiziert werden. Mit der üblichen Standardmethode, die auf einer Luftprobenahme auf Tenax® und anschließender Analyse mittels GC-MS basiert, können diese Säuren nicht ausreichend detektiert werden. Ziel dieser Arbeit ist der Vergleich von zwei unterschiedlichen Methoden zur Bestimmung von Essig- und Ameisensäure. Die Luftprobenahme der ersten Methode, die üblicherweise zur Identifizierung und Quantifizierung von VOC genutzt wird, wurde gemäß ISO 16000-6 and ISO 16017-1 auf Carbotrap® 202, ein mit mehreren Adsorbentien gepacktes Thermodesorptionsrohr, mit anschließender Identifikation und Quantifizierung mittels GC-MS durchgeführt. Die zweite Methode basiert auf einer Luftprobenahme mittels 2,4-Dinitrophenylhydrazin-(DNPH)-Kartuschen, Derivatisierung, Elution, Identifikation und Quantifizierung der Derivate mit LC-MS/MS (Flüssigkeitschromatographie – Massenspektometrie/Massenspektometrie). KW - Formic acid KW - Acetic acid KW - VVOCs KW - Air sampling KW - DNPH PY - 2012 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-255911 UR - http://www.gefahrstoffe.de/gest/article.php?data[article_id]=65887 SN - 0949-8036 SN - 0039-0771 SN - 1436-4891 VL - 72 IS - 3 SP - 84 EP - 88 PB - Springer-VDI-Verlag CY - Düsseldorf AN - OPUS4-25591 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wiegner, Katharina A1 - Farke, M. A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Hahn, Oliver T1 - Den Schadstoffen auf der Spur - Die Bewertung von Emissionen aus Materialien für Museumsausstattungen mithilfe des neuen BEMMA-Schemas N2 - Ausstellungskuratoren, Restauratoren oder Fachplaner stehen immer wieder vor der Entscheidung, geeignete Materialien für Museumsausstattungen auswählen zu müssen. Vitrinen, Depoteinrichtungen, aber auch Transportverpackungen für Kunst- und Kulturgut sollten unbedingt frei von Schadstoffen sein. Ein neues Verfahren ermöglicht nun eine problemorientierte Untersuchung und Bewertung von Materialien mit belastbaren und reproduzierbaren Ergebnissen. KW - BEMMA KW - Emissionsarme Vitrine KW - Schadstoffe PY - 2012 SN - 0933-4017 VL - 3 SP - 38 EP - 44 PB - Callwey CY - München AN - OPUS4-25794 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wiegner, Katharina A1 - Horn, Wolfgang A1 - Stephan, Ina A1 - Nohr, Michael A1 - Lau, Angelika A1 - Farke, M. A1 - Hahn, Oliver T1 - Überprüfung möglicher mikrobieller Belastungen in Vitrinenluft durch Kleinklimageräte N2 - Unterschiedliche Befeuchtungssysteme für Vitrinen, die die Ausstellungsobjekte bei definierter Luftfeuchtigkeit vor externen Einflüssen wie Staub bewahren sollen, wurden im Hinblick auf die Möglichkeit der potenziellen mikrobiologischen Kontamination untersucht. Ergänzend hierzu wurden Parameter wie pH-Wert und Leitfähigkeit des Wassers im Befeuchter untersucht und die mikrobiellen flüchtigen organischen Verbindungen (MVOC, microbial volatile organic compounds) in der Modellvitrine bestimmt. Die Leitfähigkeitsmessung kann als Indikator für den Verunreinigungsgrad des Wassers dienen, weil sie mit der mikrobiologischen Belastung korreliert. Weiterhin war eine mikrobiologische Belastung der Luft in der Modellvitrine auch bei relativ hoher Verunreinigung des Befeuchtungswassers nicht nachzuweisen. KW - MVOC (microbial volatile organic compounds) KW - Schimmelpilze KW - Kleinklimagerät KW - Vitrinen KW - Essigsäure PY - 2011 SN - 0949-8036 SN - 0039-0771 SN - 1436-4891 VL - 71 IS - 9 SP - 378 EP - 381 PB - Springer-VDI-Verl. CY - Düsseldorf AN - OPUS4-24340 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wiegner, Katharina A1 - Hahn, Oliver A1 - Farke, M. A1 - Stephan, Ina A1 - Nohr, Michael A1 - Horn, Wolfgang T1 - Development of methods for testing of microbiological contamination of small climate control units for air in display cases T2 - Healthy Buildings 2012 - 10th International conference CY - Brisbane, Australia DA - 2012-07-08 KW - Microbiological contamination KW - Acetic and formic acid KW - Conductivity KW - Climate control device KW - Display case KW - Normung KW - Geruch KW - Messmethoden KW - Emissionsmessung KW - Bauprodukte PY - 2012 SN - 978-1-921897-40-5 SP - 1 EP - 2 (5H.2) AN - OPUS4-27562 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Müller, B. A1 - Panasková, J. A1 - Müller, D. A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Scutaru, A.M. A1 - Plehn, W. T1 - Entwicklungen der Bewertungsmethodik von Gerüchen in Innenräumen N2 - Um eine gute Luftqualität in Gebäuden zu erreichen, müssen Reinigungslasten durch Lüften aus Räumen abgeführt bzw. vermieden oder verringert werden. Wird der Luftwechsel verringert, verschlechtert sich die Raumluftqualität, und die Zufriedenheit der Nutzer nimmt ab. An Arbeitsplätzen kann es bei schlechter Luftqualität und der daraus resultierenden Unzufriedenheit zu einer geringeren Produktivität der Beschäftigten kommen. Um die Reinigungslasten und deren Wirkung auf den Raumnutzer überdas Geruchsempfinden zu verringern, ist neben einer messtechnischen Erfassung der Verunreinigungen auch eine sensorische Prüfung in Innenräumen und von Bauprodukten notwendig. In diesem Artikel wird die Entwicklung der Bewertungsmethodik von Gerüchen im Innenraum erläutert und auf Anwendungen eingegangen. KW - Geruch KW - Innenraum KW - Bauprodukte KW - Bewertung PY - 2014 SN - 2195-643X VL - 135 IS - 2 SP - 70 EP - 82 PB - DIV Deutscher Industrieverlag GmbH CY - München AN - OPUS4-32403 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -