TY - JOUR A1 - Sadowski, A. A1 - Seidel, M. A1 - Al-Lawati, H. A1 - Azizi, E. A1 - Balscheit, Hagen A1 - Böhm, M. A1 - Chen, Lei A1 - van Dijk, I. A1 - Doerich-Stavridis, C. A1 - Kunle Fajuyitan, O. A1 - Filippidis, A. A1 - Winther Fischer, A. A1 - Fischer, C. A1 - Gerasimidis, S. A1 - Karampour, H. A1 - Kathirkamanathan, L. A1 - Subramanian, S. A1 - Topkaya, Cem A1 - Wagner, H. N. R. A1 - Wang, J. A1 - Wang, J. A1 - Kumar Yadav, K. A1 - Yun, X. A1 - Zhang, P. T1 - 8-MW wind turbine tower computational shell buckling benchmark - Part 1: An international ‘round-robin’ exercise N2 - An assessment of the elastic-plastic buckling limit state for multi-strake wind turbine support towers poses a particular challenge for the modern finite element analyst, who must competently navigate numerous modelling choices related to the tug-of-war between meshing and computational cost, the use of solvers that are robust to highly nonlinear behaviour, the potential for multiple near-simultaneously critical failure locations, the complex issue of imperfection sensitivity and finally the interpretation of the data into a safe and economic design. This paper reports on an international ‘round-robin’ exercise conducted in 2022 aiming to take stock of the computational shell buckling expertise around the world which attracted 29 submissions. Participants were asked to perform analyses of increasing complexity on a standardised benchmark of an 8-MW multi-strake steel wind turbine support tower segment, from a linear elastic stress analysis to a linear bifurcation analysis to a geometrically and materially nonlinear buckling analysis with imperfections. The results are a showcase of the significant shell buckling expertise now available in both industry and academia. This paper is the first of a pair. The second paper presents a detailed reference solution to the benchmark, including an illustration of the Eurocode-compliant calibration of two important imperfection forms. KW - Wind turbine tower KW - Computational KW - Shell buckling KW - Benchmark PY - 2023 DO - https://doi.org/10.1016/j.engfailanal.2023.107124 SN - 1350-6307 VL - 148 SP - 1 EP - 23 PB - Elsevier Science CY - Oxford AN - OPUS4-57019 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Alder-Rangel, A. A1 - Idnurm, A. A1 - Brand, A. A1 - Brown, A. A1 - Gorbushina, Anna A1 - Kelliher, C. A1 - Campos, C. A1 - Levin, D. A1 - Bell-Pedersen, D. A1 - Dadachova, E. A1 - Bauer, F. A1 - Gadd, G. A1 - Braus, G. A1 - Braga, G. A1 - Brancini, G. A1 - Walker, G. A1 - Druzhinina, I. A1 - Pocsi, I. A1 - Dijksterhuis, J. A1 - Aguirre, J. A1 - Hallsworth, J. A1 - Schumacher, Julia A1 - Ho Wong, K. A1 - Selbmann, L. A1 - Corrochano, L. A1 - Kupiec, M. A1 - Momany, M. A1 - Molin, M. A1 - Requena, N. A1 - Yarden, O. A1 - Cordero, R. A1 - Fischer, R. A1 - Pascon, R. A1 - Mancinelli, R. A1 - Emri, T. A1 - Basso, T. A1 - Rangel, D. T1 - The Third International Symposium on Fungal Stress - ISFUS N2 - Stress is a normal part of life for fungi, which can survive in environments considered inhospitable or hostile for other organisms. Due to the ability of fungi to respond to, survive in, and transform the environment, even under severe stresses, many researchers are exploring the mechanisms that enable fungi to adapt to stress. The International Symposium on Fungal Stress (ISFUS) brings together leading scientists from around the world who research fungal stress. This article discusses presentations given at the third ISFUS, held in Sao Jose dos Campos, Sao Paulo, Brazil in 2019, thereby summarizing the state-of-the-art knowledge on fungal stress, a field that includes microbiology, agriculture, ecology, biotechnology, medicine, and astrobiology. T2 - International Symposium on Fungal Stress (ISFUS) CY - Sao Jose dos Campos, Brazil DA - 20.05.2019 KW - Agricultural mycology KW - Fungal stress mechanisms and responses KW - Industrial mycology KW - Medical mycology PY - 2020 DO - https://doi.org/10.1016/j.funbio.2020.02.007 VL - 124 IS - 5 SP - 235 EP - 252 PB - Elsevier Ltd. AN - OPUS4-50953 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Beck, M. A1 - Becker, S. A1 - Beckmann, Jörg A1 - Cojocari, O. A1 - Feige, V. A1 - Fischer, B. A1 - Friederich, F. A1 - Globisch, B. A1 - Haupt, H. A1 - Hechtfischer, G. A1 - Hens, K. A1 - Hübers, H.-W. A1 - Jelonnek, J. A1 - Jonuscheit, J. A1 - Keil, A. A1 - Kleine-Ostmann, T. A1 - Nickel, H.-U. A1 - Peichl, M. A1 - Peters, O. A1 - Sprenger, T. A1 - Steiger, A. A1 - van Frank, S. A1 - Vieweg, N. A1 - Werner, M. A1 - Wilk, R. T1 - Terahertzsysteme - Anwendungsfelder und Systeme N2 - Die nicht ionisierende elektromagnetische Strahlung im Bereich von Terahertz-Frequenzen ermöglicht berührungslose und zerstörungsfreie Mess- und Prüftechnik in zahlreichen Bereichen. Nach ersten Anwendungen in der Astronomie und der Atmosphärenforschung wurden in letzter Zeit Anwendungsfelder in der Sicherheitstechnik, der Medizintechnik, der Nachrichtentechnik und der zerstörungsfreien Prozess- und Qualitätskontrolle erschlossen. Dielektrische Materialien wie Kunststoffe und Keramiken können von Terahertz-Wellen durchdrungen werden. Das ermöglicht Untersuchungen des Objektinneren ohne spezielle Schutzmaßnahmen, wie sie z.B. beim Röntgen notwendig sind. Die Richtlinie erleichtert die Verständigung zwischen Nutzern, Herstellern und dem Vertrieb von Terahertz-Systemen. In der Richtlinie werden bekannte Einsatzgebiete sowie die eingesetzten Verfahren und Funktionsprinzipien aufgeführt, um den Leser bei der Auswahlentscheidung zu unterstützen. Nach einer kurzen Einführung in die physikalischen Grundlagen und Hinweisen zur elektromagnetischen Verträglichkeit, zum Strahlenschutz und zur regulierten Frequenzvergabe werden die verschiedenen Geräteklassen von Terahertz-Systemen ausführlich vorgestellt. Die Richtlinie gibt Hinweise zur messtechnischen Charakterisierung von Terahertz-Wellen. Einsatzgebiete von Terahertz-Systemen, wie die zerstörungsfreie Prüfung, die Dicken- und Abstandsmessung, die Tomografie und die chemische Analytik, werden mit ihren spezifischen Eigenschaften im Detail beschrieben. Umfangreiche Literaturverweise vereinfachen eine vertiefte Beschäftigung mit den Themen der Richtlinie. Eine tabellarische Übersicht mit einer Zusammenfassung, welche Terahertz-Systeme für welche Anwendungsfelder eingesetzt werden können, vervollständigt die Richtlinie. KW - Terahertzsysteme KW - THz-Wellen PY - 2018 UR - https://www.vdi.de/5590 VL - VDI/VDE 5590 Blatt 2 SP - 1 EP - 27 PB - VDI-Verlag CY - Düsseldorf ET - Entwurf - November 2018 AN - OPUS4-46727 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Napp, J. A1 - Behnke, Thomas A1 - Fischer, L. A1 - Würth, Christian A1 - Wottawa, M. A1 - Katschinski, D.M. A1 - Alves, F. A1 - Resch-Genger, Ute A1 - Schäferling, M. T1 - Targeted luminescent near-infrared polymer-nanoprobes for in vivo imaging of tumor hypoxia N2 - Polystyrene nanoparticles (PS-NPs) were doped with an oxygen-sensitive near-infrared (NIR)-emissive palladium meso-tetraphenylporphyrin and an inert reference dye which are both excitable at 635 nm. The nanosensors were characterized with special emphasis on fundamental parameters such as absolute photoluminescence quantum yield and fluorescence lifetime. The PS-NPs were employed for ratiometric dual-wavelength and lifetime-based photoluminescent oxygen sensing. They were efficiently taken up by cultured murine alveolar macrophages, yielding a characteristic and reversible change in ratiometric response with decreasing oxygen concentration. This correlated with the cellular hypoxic status verified by analysis of hypoxia inducible factor-1α (HIF-1α) accumulation. In addition, the surface of PS-NPs was functionalized with polyethylene glycol (PEG) and the monoclonal antibody herceptin, and their binding to HER2/neu-overexpressing tumor cells was confirmed in vitro. First experiments with tumor-bearing mouse revealed a distinctive ratiometric response within the tumor upon hypoxic condition induced by animal sacrifice. These results demonstrate the potential of these referenced NIR nanosensors for in vitro and in vivo imaging that present a new generation of optical probes for oncology. KW - Fluorescence KW - NIR KW - Nanoparticles KW - Microparticles KW - Imaging KW - Cancer KW - Oxygene PY - 2011 DO - https://doi.org/10.1021/ac201870b SN - 0003-2700 SN - 1520-6882 VL - 83 IS - 23 SP - 9039 EP - 9046 PB - American Chemical Society CY - Washington, DC AN - OPUS4-24987 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Becker, S. A1 - Beckmann, Jörg A1 - Braun, M.-T. A1 - Cojocari, O. A1 - Feige, V. A1 - Fischer, B. A1 - Friederich, F. A1 - Globisch, B. A1 - Hechtfischer, G. A1 - Hens, K. A1 - Hübers, H.-W. A1 - Jelonnek, J. A1 - Jonuscheit, J. A1 - Keil, A. A1 - Kleine-Ostmann, T. A1 - Marquardt, E. A1 - Mayr, M. A1 - Nickel, H.-U. A1 - Nüßler, D. A1 - Peichl, M. A1 - Peters, O. A1 - Schür, J. A1 - Sprenger, T. A1 - Steiger, A. A1 - van Frank, S. A1 - Vieweg, N. A1 - Wilk, R. ED - Jonuscheit, J. ED - Marquardt, E. T1 - Terahertzsysteme und Anwendungsfelder N2 - Der Frequenzbereich der Terahertzwellen liegt im elektromagnetischen Spektrum zwischen den Mikrowellen und dem infraroten Licht – also etwa im Bereich von 0,1 bis 10 Terahertz (THz). Der VDI-Statusreport „Terahertzsysteme und Anwendungen“ stellt die unterschiedlichen Konzepte für Terahertzsysteme vor und zeigt Anwendungsbeispiele, bei denen die Terahertztechnik erfolgreich eingesetzt wird. Umfangreiche Literaturangaben ermöglichen eine intensivere Beschäftigung mit allen Themen des VDI-Statusreports. KW - Terahertzsysteme PY - 2020 UR - https://www.vdi.de/ueber-uns/presse/publikationen/details/terahertzsysteme-und-anwendungsfelder SP - 1 EP - 44 PB - Verein Deutscher Ingenieure (VDI) CY - Düsseldorf AN - OPUS4-50556 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Brose, M. A1 - Ludwig, Th. A1 - Püster, Th. A1 - Bunte, J. A1 - Fiedler, A. A1 - Fischer, M. A1 - Heberer, E. A1 - Kautek, Wolfgang A1 - Spielmann, Ch. T1 - Ultrakurzpuls-Laser: Anwendungen, Risiken, Sicherheitsmaßnahmen KW - Arbeitsschutz KW - Lasersicherheit KW - Ultrakurzpuls-Laser KW - Femtosekunden-Technologie KW - Laserstrahlung KW - Strahlenschutz PY - 2004 SN - 0947-434X VL - 9 IS - 2 SP - 34 EP - 43 PB - Verl. TÜV Rheinland CY - Köln AN - OPUS4-3586 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Abou-Ras, D. A1 - Caballero, R. A1 - Fischer, C.-H. A1 - Kaufmann, C.A. A1 - Lauermann, I. A1 - Mainz, R. A1 - Mönig, H. A1 - Schöpke, A. A1 - Stephan, C. A1 - Streeck, C. A1 - Schorr, S. A1 - Eicke, A. A1 - Döbeli, M. A1 - Gade, B. A1 - Hinrichs, J. A1 - Nunney, T. A1 - Dijkstra, H. A1 - Hoffmann, V. A1 - Klemm, D. A1 - Efimova, V. A1 - Bergmaier, A. A1 - Dollinger, G. A1 - Wirth, Thomas A1 - Unger, Wolfgang A1 - Rockett, A.A. A1 - Perez-Rodriguez, A. A1 - Alvarez-Garcia, J. A1 - Izquierdo-Roca, V. A1 - Schmid, T. A1 - Choi, P.-P. A1 - Müller, M. A1 - Bertram, F. A1 - Christen, J. A1 - Khatri, H. A1 - Collins, R.W. A1 - Marsillac, S. A1 - Kötschau, I. T1 - Comprehensive comparison of various techniques for the analysis of elemental distributions in thin films N2 - The present work shows results on elemental distribution analyses in Cu(In,Ga)Se2 thin films for solar cells performed by use of wavelength-dispersive and energy-dispersive X-ray spectrometry (EDX) in a scanning electron microscope, EDX in a transmission electron microscope, X-ray photoelectron, angle-dependent soft X-ray emission, secondary ion-mass (SIMS), time-of-flight SIMS, sputtered neutral mass, glow-discharge optical emission and glow-discharge mass, Auger electron, and Rutherford backscattering spectrometry, by use of scanning Auger electron microscopy, Raman depth profiling, and Raman mapping, as well as by use of elastic recoil detection analysis, grazing-incidence X-ray and electron backscatter diffraction, and grazing-incidence X-ray fluorescence analysis. The Cu(In,Ga)Se2 thin films used for the present comparison were produced during the same identical deposition run and exhibit thicknesses of about 2 µm. The analysis techniques were compared with respect to their spatial and depth resolutions, measuring speeds, availabilities, and detection limits. KW - Elemental distributions KW - Comparison KW - Depth profiling KW - Chemical mapping KW - Thin films KW - Solar cells KW - Chalcopyrite-type KW - Cu(In,Ga)Se2 PY - 2011 DO - https://doi.org/10.1017/S1431927611000523 SN - 1431-9276 SN - 1435-8115 VL - 17 IS - 5 SP - 728 EP - 751 PB - Cambridge University Press CY - New York, NY AN - OPUS4-24506 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kormunda, M. A1 - Fischer, Daniel A1 - Hertwig, Andreas A1 - Beck, Uwe A1 - Sebik, M. A1 - Esser, N. T1 - Preparation of pulsed DC magnetron deposited Fe-doped SnO2 coatings N2 - Iron-doped SnO2 coatings were deposited in a 50 kHz DC-pulsed magnetron sputtering discharge. The pulses had a duration of 4 µs in selected gas mixtures from pure argon up to 60% of oxygen at a constant total pressure of 0.2 Pa. A single target of SnO2 with Fe inset was used. The mass spectrometry study detected the gas-related ions Ar+, O2+ and O+, where the last one becomes the dominant positive ion at higher oxygen contents. Atomic oxygen ions had a higher energy as it resulted from the collision-caused dissociation on the target surface. The tin-related species were detected as Sn+ and SnO+. SnO2+ species were not detected. The deposition rate decreased by using gas mixtures with oxygen as well as the corresponding amount of Sn-related species in the plasma. The increase of oxygen also increased significantly the sheet resistance of the films. The XPS study showed that the iron concentration decreased by using additional oxygen. But the O/Sn ratio in the coatings was constant, contrary to the increased FeO/Fe ratio in the films. An additional analysis of the coatings by spectroscopic ellipsometry has shown a dependence of the polarizability and the permittivity on the amount of oxygen used during the deposition. In contrast, the study has found no such dependence for the absorption of the layers. KW - Coatings KW - Magnetron sputtering KW - Optical properties KW - Sheet resistivity KW - SnO2 PY - 2016 UR - http://onlinelibrary.wiley.com/doi/10.1002/pssa.201532882/full DO - https://doi.org/10.1002/pssa.201532882 SN - 0031-8965 SN - 1862-6300 VL - 213 IS - 9 SP - 2303 EP - 2309 PB - WILEY-VCH Verlag GmbH & Co. KGaA CY - Weinheim AN - OPUS4-38106 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Weber, A. A1 - von Randow, M. A1 - Voigt, A.-L. A1 - von der Au, Marcus A1 - Fischer, E. A1 - Meermann, Björn A1 - Wagner, M. T1 - Ingestion and toxicity of microplastics in the freshwater gastropodLymnaea stagnalis: No microplastic-induced effects alone or incombination with copper N2 - The interaction of microplastics with freshwater biota and their interaction with other stressors is still not very well understood. Therefore, we investigated the ingestion, excretion and toxicity of microplastics in the freshwater gastropod Lymnaea stagnalis. MP ingestion was analyzed as tissues levels in L. stagnalis after 6–96 h of exposure to 5–90 μm spherical polystyrene (PS) microplastics. To understand the excretion, tissue levels were determined after 24 h of exposure followed by a 12 h–7 d depuration period. To assess the toxicity, snails were exposed for 28 d to irregular PS microplastics (<63 μm, 6.4–100,000 particles mL−1), both alone and in combination with copper as additional stressor. To compare the toxicity of natural and synthetic particles, we also included diatomite particles. Microplastics ingestion and excretion significantly depended on the particle size and the exposure/depuration duration. An exposure to irregular PS had no effect on survival, reproduction, energy reserves and oxidative stress. However, we observed slight effects on immune cell phagocytosis. Exposure to microplastics did not exacerbate the reproductive toxicity of copper. In addition, there was no pronounced difference between the effects of microplastics and diatomite. The tolerance towards microplastics may originate from an adaptation of L. stagnalis to particle-rich environments or a general stress resilience. In conclusion, despite high uptake rates, PS fragments do not appear to be a relevant stressor for stress tolerant freshwater gastropods considering current environmental levels of microplastics. KW - Lymnaea stagnalis KW - Microplastic-induced effects KW - Mixture toxicity PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-513551 DO - https://doi.org/10.1016/j.chemosphere.2020.128040 VL - 263 SP - 128040 PB - Elsevier Ltd. AN - OPUS4-51355 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kormunda, M. A1 - Fischer, Daniel A1 - Hertwig, Andreas A1 - Beck, Uwe A1 - Sebik, M. A1 - Pavlik, J. A1 - Esser, N. T1 - Deposition and characterization of single magnetron deposited Fe:SnOx coatings N2 - Coatings deposited by magnetron co-sputtering from a single RF magnetron with a ceramic SnO2 target with iron inset in argon plasma were studied. The mass spectra of the process identified Sn+ and SnO+ species as the dominant species sputtered from the target, but no SnO2+ species were detected. The dominant positive ions in argon plasma are Ar+ species. The only detected negative ions were O-. Sputtered neutral tin related species were not detected. Iron related species were also not detected because their concentration is below the detection limit. The concentration of iron dopant in the tin oxide coatings was controlled by the RF bias applied on the substrate holder while the discharge pressure also has some influence. The iron concentration was in the range from 0.9 at.% up to 19 at.% increasing with the substrate bias while the sheet resistivity decreases. The stoichiometry ratio of O/(Sn + Fe) in the coatings increased from 1.7 up to 2 in dependence on the substrate bias from floating bias (- 5 V) up to - 120 V of RF self-bias, respectively. The tin in the coatings was mainly bonded in Sn4 + state and iron was mainly in Fe2 + state when other tin bonding states were detected only in a small amounts. Iron bonding states in contrary to elemental compositions of the coatings were not influenced by the RF bias applied on the substrate. The coatings showed high transparency in the visible spectral range. However, an increased metallic behavior could be detected by using a higher RF bias for the deposition. The X-ray diffraction patterns and electron microscopy pictures made on the coatings confirmed the presence of an amorphous phase. KW - Metal oxides KW - Transparent conductive oxides (TCO) KW - Magnetron KW - Optical properties KW - Ellipsometry KW - XPS characterzation PY - 2015 DO - https://doi.org/10.1016/j.tsf.2015.11.009 SN - 0040-6090 VL - 595 IS - Part A SP - 200 EP - 208 PB - Elsevier B.V. CY - Amsterdam AN - OPUS4-35281 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Florian, Camilo A1 - Fischer, Daniel A1 - Freiberg, K. A1 - Duwe, M. A1 - Sahre, Mario A1 - Schneider, S. A1 - Hertwig, Andreas A1 - Krüger, Jörg A1 - Rettenmayr, M. A1 - Beck, Uwe A1 - Undisz, A. A1 - Bonse, Jörn T1 - Single Femtosecond Laser-Pulse-Induced Superficial Amorphization and Re-Crystallization of Silicon N2 - Superficial amorphization and re-crystallization of silicon in <111> and <100> orientation after irradiation by femtosecond laser pulses (790 nm, 30 fs) are studied using optical imaging and transmission electron microscopy. Spectroscopic imaging ellipsometry (SIE) allows fast data acquisition at multiple wavelengths and provides experimental data for calculating nanometric amorphous layer thickness profiles with micrometric lateral resolution based on a thin-film layer model. For a radially Gaussian laser beam and at moderate peak fluences above the melting and below the ablation thresholds, laterally parabolic amorphous layer profiles with maximum thicknesses of several tens of nanometers were quantitatively attained. The accuracy of the calculations is verified experimentally by high-resolution transmission electron microscopy (HRTEM) and energy dispersive X-ray spectroscopy (STEM-EDX). Along with topographic information obtained by atomic force microscopy (AFM), a comprehensive picture of the superficial re-solidification of silicon after local melting by femtosecond laser pulses is drawn. KW - Femtosecond laser KW - Silicon KW - Amorphization KW - Crystallization KW - Spectroscopic imaging ellipsometry PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-523687 UR - https://www.mdpi.com/1996-1944/14/7/1651 DO - https://doi.org/10.3390/ma14071651 SN - 1996-1944 VL - 14 IS - 7 SP - 1651-1 EP - 1651-21 PB - MDPI AG CY - Basel, Switzerland AN - OPUS4-52368 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Guerra, M. F. A1 - Fischer, M. A1 - Radtke, Martin A1 - Reinholz, Uwe T1 - Inca figurines from the Ethnologisches Museum in Berlin: an analytical study of some typical and atypical productions N2 - Fourteen hollow and one cast anthropomorphic and zoomorphic figurines produced in Incan times for ritual offerings from the Ethnologisches Museum in Berlin were selected to investigate the technologies and alloys used for their fabrication with portable optical microscopy and non-destructive XRF elemental analysis. This group of gold and silver figurines includes typical specimens of the Inca production, such as the four silver figurines from the Island Coati in Lake Titicaca and the two gold figurines from Pachacamac, as well as specimens that are seldom present in collections, which makes them atypical. In addition to the tall figurines with atypical hair or standing pose, one bicolour figurine half silver, half gold) and another with coloured inlays were included in this study for comparison. The large majority of the silver specimens are made from very high quality alloys and the gold figurines are made from alloys containing low copper contents and silver ranging from 30wt% to 52wt%. KW - Gold KW - pXRF KW - Inca PY - 2017 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-436015 DO - https://doi.org/10.4000/bifea.8232 SN - 0303-7495 VL - 46 IS - 1 SP - 221 EP - 251 PB - Institut Français d'Études Andines AN - OPUS4-43601 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Becker, S. A1 - Beckmann, Jörg A1 - Cojocari, O. A1 - Feige, V. A1 - Fischer, B. A1 - Friederich, F. A1 - Globisch, B. A1 - Hechtfischer, G. A1 - Hens, K. A1 - Hübers, H.-W. A1 - Jelonnek, J. A1 - Jonuscheit, J. A1 - Keil, A. A1 - Kleine-Ostmann, T. A1 - Mayr, M. A1 - Nüßler, D. A1 - Peichl, M. A1 - Peters, O. A1 - Schür, J. A1 - Sprenger, T. A1 - Steiger, A. A1 - van Frank, S. A1 - Vieweg, N. A1 - Wilk, R. T1 - Terahertzsysteme - Zeitbereichsspektrometer (TDS-Systeme) N2 - Diese Richtlinie definiert Kenngrößen und Messverfahren, um Terahertzsysteme für die Zeitbereichsspektroskopie (TDS)zu spezifizieren. So können Hersteller ihre Systeme übereinstimmend beschreiben und Anwender einfach Systeme vergleichen. Systeme für die Terahertz-Zeitbereichsspektroskopie sind aktive Systeme und nutzen verschiedene Techniken sowohl zur Erzeugung als auch zur zeitaufgelösten Messung von breitbandigen Terahertzimpulsen. Die dazugehörigen Terahertzspektren und -Phasen werden nach einer zeitlichen Abtastung über eine Fourier-Transformation berechnet. In dieser Richtlinie wird ein Überblick über die Funktionsweisen von Zeitbereichsspektrometern gegeben, die eingesetzten Messverfahren näher erläutert sowie die benötigten Begriffe und Kenngrößen definiert. Die Richtlinie konzentriert sich dabei auf Systeme, die auf sogenannten Abtastmessverfahren (Sampling-Messverfahren) basieren. KW - TDS-Systeme PY - 2020 UR - https://www.vdi.de/5590 VL - VDI/VDE 5590 Blatt 2 SP - 1 EP - 22 PB - VDI-Verlag CY - Düsseldorf ET - Entwurf - Oktober 2020 AN - OPUS4-51947 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pospiech, D. A1 - Fischer, O. A1 - Korwitz, A. A1 - Hoffmann, T. A1 - Köppl, T. A1 - Altstädt, V. A1 - Ciesielski, M. A1 - Döring, M. A1 - Brehme, Sven A1 - Schartel, Bernhard A1 - Vollmerhausen, D. T1 - Designed flame retardancy with phosphorus polymers N2 - Polymeric flame retardants offer the possibility to match effective flame retardancy with the requirements of new regulations. Synthesis, properties and efficiency in polymer matrices are discussed for two systems, epoxy resins as well as poly(butylene terephthalate). T2 - 25th Annual conference: Recent advances in flame retardancy of polymeric materials CY - Stamford, Connecticut, USA DA - 18.05.2014 KW - Flame retardancy KW - Phosphorus polymer KW - Poly(butylene terephthalate) KW - Epoxy resin PY - 2014 SP - 1 EP - 5 AN - OPUS4-30951 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Brehme, Sven A1 - Schartel, Bernhard A1 - Bykov, Y. A1 - Ciesielski, M. A1 - Döring, M. A1 - Fischer, O. A1 - Pospiech, D. A1 - Köppl, T. A1 - Altstädt, V. T1 - Flame retardancy mechanisms and performance of a halogen-free phosphorus polyester in PBT N2 - PET-P-DOPO is a phosphorus-containing polyester prepared from the glycol ether of the hydroquinone derivative of 9,10-dihydro-9-oxa-10-phosphaphenanthrene-10-oxide (DOPO) and dimethyl terephthalate. PET-P-DOPO and a blend of PBT with PET-PDOPO were investigated with respect to pyrolysis and fire behavior. PET-P-DOPO achieves a V-0 rating in the UL 94 test and exhibits a high LOI of 39.3%. The outstanding flame-retardant properties of PET-P-DOPO are the result of three different mechanisms (flame inhibition, charring and a protection effect of the intumescent char) that are active in PET-P-DOPO. The fire load and the peak of heat release rate (pHRR) are reduced to 34% and 17%, respectively. The char exhibits an intumescent multicellular structure enabling it to act as an efficient protection layer. As PET-P-DOPO is immiscible with PBT, the blend shows a lower breaking elongation than pure PBT. Compared to pure PET-P-DOPO, the flame retardancy of the blend is decreased according to the fraction of PET-P-DOPO used. Nevertheless, the flame-retardancy of PET-P-DOPO in the blend was good enough to compete with PBT flame-retarded by AlPi-Et (aluminum diethylphosphinate) that was used as a Benchmark. KW - PBT KW - DOPO KW - Flame retardancy PY - 2011 SN - 1-59623-795-3 SP - 1 EP - 15 CY - Wellesley, USA AN - OPUS4-24617 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schneider, Ronald A1 - Fischer, J. A1 - Bügler, M. A1 - Nowak, M. A1 - Thöns, S. A1 - Borrmann, A. A1 - Straub, D. T1 - Assessing and updating the reliability of concrete bridges subjected to spatial deterioration - principles and software implementation N2 - Inspection and maintenance of concrete bridges is a major cost factor in transportation infrastructure, and there is significant potential for using information gained during inspection to update predictive models of the performance and reliability of such structures. In this context, this paper presents an approach for assessing and updating the reliability of prestressed concrete bridges subjected to chloride-induced reinforcement corrosion. The system deterioration state is determined based on a Dynamic Bayesian Network (DBN) model that considers the spatial variability of the corrosion process. The overall system reliability is computed by means of a probabilistic structural model coupled with the deterioration model. Inspection data are included in the system reliability calculation through Bayesian updating on the basis of the DBN model. As proof of concept, a software prototype is developed to implement the method presented here. The software prototype is applied to a typical highway bridge and the influence of inspection information on the system deterioration state and the structural reliability is quantified taking into account the spatial correlation of the corrosion process. This work is a step towards developing a software tool that can be used by engineering practitioners to perform reliability assessments of ageing concrete bridges and update their reliability with inspection and monitoring data. KW - Structural reliability KW - Dynamic Bayesian Networks KW - Spatial deterioration KW - Inspection KW - Monitoring general KW - Analysis and design methods KW - Reinforcement KW - Corrosion KW - Prestressed concrete PY - 2015 DO - https://doi.org/10.1002/suco.201500014 SN - 1464-4177 VL - 16 IS - 3 SP - 356 EP - 365 PB - Ernst & Sohn CY - Berlin AN - OPUS4-34336 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Fischer, C. A1 - Schmidt, Martin A1 - Meyer, U. A1 - Barth, Uli A1 - Drebenstedt, C. A1 - Wuttke, M. W. T1 - Innovative Technologien für die Erkundung, Löschung und Beobachtung von Kohlebränden - Phase B - N2 - Aufbauend auf den Erkenntnissen der Phase A, die sich auf das grundlegende Verständnis von Kohlebränden, sowie der Voraussetzung und des prinzipiellen Ablaufs der physikalischchemischen Brandprozesse konzentriert haben, erfolgte in Phase B eine Fokussierung auf Methoden zur Vermeidung von Kohlebränden, sowie der Löschung und Überwachung von Kohlebrandzonen, um einen Beitrag zur Verminderung von C02-Emissionen und zum Erhalt der nutzbaren Energieressourcen leisten zu können. Diese Arbeiten erfolgten insbesondere mit Bezug zu den „Clean Development Mechanisms“ (CDM), die im Rahmen des Kyoto-Protokolls entwickelt worden sind. Eine Zertifizierung von Löschaktivitäten im Rahmen des Kyoto-Protokolls setzt dabei eine nachvollziehbare Ermittlung der kohlebrandbezogenen C02-Emissionen und eine belastbare Abschätzung der durch die Löschung verringerten Emissionsmengen voraus. Wesentliche Arbeiten konzentrierten sich auf die Entwicklung von Verfahren, die eine solche Abschätzung gewährleisten können. Dazu wurden unterschiedliche Ansätze entwickelt und anhand der erhobenen Felddaten überprüft. Die untersuchten Ansätze konzentrierten sich dabei auf Verfahren, die eine Ermittlung des vorhandenen Kohlevolumens, die Erfassung der emittierten Gase und die durch die Kohlebrände verursachten Temperaturanomalien an der Tagesoberfläche ermöglichen. Die direkten Arbeiten zum Thema CDM wurden dabei in einem Arbeitspaket unter Federführung der BGR gebündelt. Die deutsche Initiative zur Erforschung der Kohlenbrände in der V.R. China leistete zweifelsfrei signifikante Beiträge zu den oben genannten Zielen. Durch die inventiven Ansätze im Bereich der Brandbewältigung konnte darüber hinaus auch in Teilen die ökonomischen Chancen für ein Engagement deutscher Unternehmen aufgezeigt werden. KW - Kohlebrände KW - Brandbekämpfung KW - Branderkundung PY - 2011 DO - https://doi.org/10.2314/GBV:664529690 SP - 1 EP - 39 AN - OPUS4-25013 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ast, S. A1 - Fischer, Tobias A1 - Müller, H. A1 - Mickler, W. A1 - Schwichtenberg, M. A1 - Rurack, Knut A1 - Holdt, H.-J. T1 - Integration of the 1,2,3-triazole 'click' motif as a potent signalling element in metal ion responsive fluorescent probes N2 - In a systematic approach we synthesized a new series of fluorescent probes incorporating donor–acceptor (D-A) substituted 1,2,3-triazoles as conjugative π-linkers between the alkali metal ion receptor N-phenylaza-[18]crown-6 and different fluorophoric groups with different electron-acceptor properties (4-naphthalimide, meso-phenyl-BODIPY and 9-anthracene) and investigated their performance in organic and aqueous environments (physiological conditions). In the charge-transfer (CT) type probes 1, 2 and 7, the fluorescence is almost completely quenched by intramolecular CT (ICT) processes involving charge-separated states. In the presence of Na+ and K+ ICT is interrupted, which resulted in a lighting-up of the fluorescence in acetonitrile. Among the investigated fluoroionophores, compound 7, which contains a 9-anthracenyl moiety as the electron-accepting fluorophore, is the only probe which retains light-up features in water and works as a highly K+/Na+-selective probe under simulated physiological conditions. Virtually decoupled BODIPY-based 6 and photoinduced electron transfer (PET) type probes 3–5, where the 10-substituted anthracen-9-yl fluorophores are connected to the 1,2,3-triazole through a methylene spacer, show strong ion-induced fluorescence enhancement in acetonitrile, but not under physiological conditions. Electrochemical studies and theoretical calculations were used to assess and support the underlying mechanisms for the new ICT and PET 1,2,3-triazole fluoroionophores. KW - Charge transfer KW - Click chemistry KW - Electron transfer KW - Fluorescent probes KW - Metal ions PY - 2013 DO - https://doi.org/10.1002/chem.201201575 SN - 0947-6539 SN - 1521-3765 VL - 19 IS - 9 SP - 2990 EP - 3005 PB - Wiley-VCH Verl. CY - Weinheim AN - OPUS4-27742 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Rudtsch, S. A1 - Fahr, M. A1 - Fischer, J. A1 - Gusarova, Tamara A1 - Kipphardt, Heinrich A1 - Matschat, Ralf T1 - High-Purity Fixed Points of the ITS-90 with Traceable Analysis of Impurity Contents N2 - The International Temperature Scale of 1990 (ITS-90) is based on thermodynamic equilibrium states of ideally pure substances. The largest contribution to the uncertainty budgets of most metallic fixed points is the influence of impurities on the fixed-point temperature. Therefore, a traceable chemical analysis of the remaining impurities with small uncertainty is the basis of further progress. Further requirements are better knowledge of the phase diagrams at very low impurity contents, impurity segregation, and the quantification and correction of thermal effects during a fixed-point realization. In this article, current and future activities at PTB and BAM in order to develop improved metallic fixed-point cells of the ITS-90 are reviewed. KW - Chemical analysis KW - Fixed points KW - Impurities KW - ITS-90 KW - Phase diagrams KW - Thermal effects PY - 2008 DO - https://doi.org/10.1007/s10765-007-0358-9 SN - 0195-928X SN - 1572-9567 VL - 29 IS - 1 SP - 139 EP - 150 PB - Springer CY - Dordrecht AN - OPUS4-17455 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Allsop, N. A. A1 - Schönmann, A. A1 - Belaidi, A. A1 - Muffler, H.-J. A1 - Mertesacker, B. A1 - Bohne, W. A1 - Strub, Erik A1 - Röhrich, J. A1 - Lux-Steiner, M. C. A1 - Fischer, C.-H. T1 - Indium sulfide thin films deposited by the spray ion layer gas reaction technique N2 - The Spray Ion Layer Gas Reaction (Spray-ILGAR) technique is a new variation on the ILGAR technique used to prepare chalcogenide thin films. High quality indium sulfide thin films were produced by Spray-ILGAR with an indirect bandgap of 2.2 eV and a high suitability for use as buffer layers in chalcopyrite solar cells. The process involves the cyclical spray deposition of an indium containing precursor layer followed by its conversion to sulfide using hydrogen sulfide gas. Analysis of the deposition reveals that the indium chloride based precursor is transported via the vapour phase from the spray droplets to the substrate surface. KW - Spray deposition KW - Indium sulfide KW - Ion layer gas reaction KW - ILGAR KW - X-ray diffraction KW - X-ray fluorescence KW - Deposition process PY - 2006 DO - https://doi.org/10.1016/j.tsf.2006.01.019 SN - 0040-6090 VL - 513 IS - 1-2 SP - 52 EP - 56 PB - Elsevier CY - Amsterdam AN - OPUS4-14267 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -