TY - GEN A1 - Krüger, Jörg A1 - Lenzner, Matthias A1 - Martin, Sven A1 - Lenner, M. A1 - Spielmann, C. A1 - Fiedler, A. A1 - Kautek, Wolfgang ED - Phipps, C. R. T1 - Femtosecond laser induced damage in absorbing filters used for laser protection N2 - Damage experiments of absorbing filters (Schott BG18 and BG36) were performed with Ti:sapphire laser pulses with durations from 30 fs to 340 fs (800 nm, 1 kHz) in air. The direct focusing technique was employed under single- and multi-pulse irradiation conditions. Ablation threshold fluences were determined from a semi-logarithmic plot of the ablation crater diameter vs. laser fluence. The damage threshold fluence decreases for shorter pulse durations. In the investigated pulse duration range, the measured multi-pulse ablation threshold fluences are practically similar to those of undoped glass material (~1 Jcm-2). That means that the multi-pulse ablation threshold is independent on the doping level of the filters. For more than 100 pulses per spot and all pulse durations applied, the threshold fluence saturates. This leads to technically relevant damage threshold values in the femtosecond laser pulse duration domain. T2 - 4th SPIE's International Conference on High-Power Laser Ablation CY - Taos, NM, USA DA - 2002-04-22 KW - Ablation KW - Damage KW - Eye protection KW - Femtosecond pulse laser KW - Incubation KW - Laser safety KW - Threshold fluence PY - 2002 SN - 0-8194-4524-X DO - https://doi.org/10.1117/12.482109 SN - 1605-7422 N1 - Serientitel: SPIE proceedings series – Series title: SPIE proceedings series VL - 1 IS - 4760 SP - 398 EP - 405 PB - SPIE CY - Bellingham, Wash. AN - OPUS4-1550 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kautek, Wolfgang A1 - Krüger, Jörg A1 - Lenzner, Matthias A1 - Martin, Sven A1 - Lenner, M. A1 - Spielmann, C. A1 - Fiedler, A. ED - Meunier, M. T1 - Single- and multi-pulse femtosecond laser ablation of optical filter materials N2 - Commercially available absorption filters (Schott BG18 and BG36) were investigated with respect to their single- and multi-pulse ablation threshold using laser pulses from a Ti:Sapphire laser in the range between 30 and 340 fs. It could be observed, that the threshold fluence decreases for shorter pulse durations. The similarity of the measured multi-pulse threshold fluences with those of undoped glass material (around 1 J/cm^2 for a pulse duration of 30 fs) suggests that, for very short pulses, the threshold is independent on the doping level and therefore, linear absorption does not significantly contribute to laser-induced damage. For >100 pulses per spot and all pulse durations applied, the threshold fluences saturate. This independence on the number of applied pulses leads to technically relevant damage threshold values. T2 - Symposium D - European Materials Research Society CY - Strasbourg, France DA - 2002-06-18 PY - 2002 UR - http://www.emrs-strasbourg.com/files/pdf/2002_SPRING/02_Prog_Dv2.pdf N1 - Serientitel: Applied surface science – Series title: Applied surface science VL - 208/209.2003,1 IS - 1 SP - 1(?) PB - Elsevier CY - Amsterdam AN - OPUS4-1588 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Beutel, R. A1 - Reinhardt, H.-W. A1 - Grosse, C. U. A1 - Glaubitt, A. A1 - Krause, Martin A1 - Maierhofer, Christiane A1 - Algernon, Daniel A1 - Wiggenhauser, Herbert A1 - Schickert, M. T1 - Performance Demonstration of Non-Destructive Testing Methods T2 - 9th European Conference on NDT CY - Berlin, Germany DA - 2006-09-25 KW - NDT-CE KW - Concrete KW - Ultrasonic echo KW - Impact-echo KW - Radar KW - Concrete cover of tendon ducts KW - Thickness measurement KW - Concrete slabs PY - 2006 SN - 3-931381-86-2 SP - 1(?) EP - 9(?) PB - European Federation for Non-Destructive Testing CY - Berlin AN - OPUS4-14382 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Tuma, Dirk A1 - Moreau, A. A1 - Polishuk, I. A1 - Segovia, J. J. A1 - Vega-Maza, D. A1 - Martín, M. C. T1 - Measurements and predictions of densities and viscosities in CO2 + hydrocarbon mixtures at high pressures and temperatures: CO2 + n-pentane and CO2 + n-hexane blends N2 - This work reports new experimental data on densities and viscosities of (CO2 + n-pentane) and (CO2 + n-hexane) mixtures at high pressures and temperatures. The densities were measured by a vibrating-tube densimeter with an expanded uncertainty (k = 2) smaller than 1.8 kg/m3 at six isotherms (from 273.15 K to 373.15 K), twelve pressures starting at 5 MPa up to 100 MPa, and at six CO2 molar compositions (from 0 to 0.6). The viscosities were measured by a vibrating-wire viscometer with the corresponding relative expanded uncertainty (k = 2) smaller than 0.016 at five isotherms (from 273.15 K to 373.15 K), twelve pressures (from 5 MPa up to 100 MPa), and at two CO2 molar compositions (0.1 and 0.3). The densities were fitted by the semiempirical Tammann-Tait equation for density data and the Vogel-Fulcher-Tammann (VFT) equation for viscosity data, respectively. The Groupe Européen de Recherches Gazières (GERG-2008) equation of state was also applied for modelling the densities. Over-all robustness and reliability of the Perturbed-Chain Statistical Association Fluid Theory (PC-SAFT) and its critical point-based modification (CP-PC-SAFT) were examined. Accuracies of the Modified Yarranton-Satyro (MYS) coupled with CP-PC-SAFT and the NIST Reference Fluid Thermodynamic and Transport Properties Database (REFPROP 10) in predicting the viscosities were evaluated. KW - CO2 + n-alkanes KW - thermophysical properties KW - Perturbed-Chain Statistical Association Fluid Theory PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-555728 DO - https://doi.org/10.1016/j.molliq.2022.119518 SN - 0167-7322 VL - 360 SP - 1 EP - 15 PB - Elsevier CY - Amsterdam AN - OPUS4-55572 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Gruskovà, J. A1 - Martin, G. A1 - Kresten, O. A1 - Mitthoff, F. A1 - Kaska, K. A1 - Hofmann, C. A1 - Kreuzer, W. A1 - Phelps, M. A1 - Boydston, K. A1 - Easton Jr., R. L. A1 - Knox, K. T. A1 - Kelbe, D. A1 - Kasotakis, D. A1 - Christens-Barry, W. A. A1 - Stewart, D. A1 - Rabin, Ira A1 - Hahn, Oliver A1 - Glaser, L. A1 - Garrevoet, J. A1 - Shevchuk, I. A1 - Klumpp, S. A1 - Deckers, D. A1 - Buck, J. ED - Cronier, M. ED - Mondrain, B. T1 - Insights-into-the-Digital-Recovery-of-the-Scythica-Vindobonesia N2 - The Scythica Vindobonensia, the new fragments on Gothic incursions into Roman provinces in the Balkans in the middle of the third century AD that were revealed some years ago in a Greek palimpsest at the Austrian National Library in Vienna (ÖNB), are commonly considered as one of the most important additions of the last decades to the corpus of texts from classical Antiquity. Tere is a high degree of confdence among scholars in supposing that the fragments come from the lost work Scythica written in Greek by the third-century historian P. Herennius Dexippus (Δέξιππος) of Athens. The new fragments have hence also been called Dexippus Vindobonensis. In his Scythica, Dexippus recorded wars of the Romans with the Goths (and other tribes) whom he called Scythians. The work had been hitherto known only from excerpts and quotes by later authors. Eight pages of a Byzantine manuscript copy of the ancient text have survived hidden underneath the visible surface of the last four parchment folios of the Vienna manuscript Historicus graecus 73, f. 192r -195v4. The copy is written in a Greek calligraphic minuscule which has been estimated by palaeographers to be of the middle or the second half of the eleventh century. In the thirteenth century, the text (on each of the eight pages arranged in one column, with 30 lines per page) was washed of the parchment and the valuable material made from animal skin was re-used for Christian texts. The new writing largely covered the faded remnants of the original text. It thus became hidden from the human eye for more than seven hundred years. Its discovery by Jana Grusková, a classical philologist specialized in the transmission of Greek texts, resulted from a systematic review of all Greek palimpsests kept at the Austrian National Library in Vienna at the beginning of the twenty-first century and a detailed examination of the four folios in 2007-20097. KW - Scythica Vindobonensia, KW - Gothic incursions KW - A Greek palimpsest KW - Antiquity KW - Byzantine manuscript KW - Vienna manuscript PY - 2020 SN - 978-2-916716-81-7 SN - 0577-1471 VL - 2020 IS - 24/1 SP - 945 EP - 967 PB - Association des Amis du Centre d’Histoire et Civilisation de Byzance CY - Paris ET - 1 AN - OPUS4-53843 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Lezhnina, M.M. A1 - Kätker, H. A1 - Kaiser, Martin A1 - Stegemann, L. A1 - Voss, E. A1 - Resch-Genger, Ute A1 - Strassert, C. A1 - Kynast, U. T1 - Chemical behavior and spectroscopic properties of rare earth borates in glazes N2 - Efficient Near UV excited materials (350<λ<400 nm) responding with green line emission are sparse in comparison to higher energy UV excited emitters (λ<350 nm), while corresponding red line emitters are more abundant, albeit typically also restricted to excitation wavelengths below 400 nm. This situation is disadvantageous for several important actual and potential applications. Among these, excitation with high power UV-LEDs and laser diodes are of particular interest. Here we present results on green emitting YBO3:Ce, Tb, which can be excited with 370–380 nm radiation at quantum efficiencies of up to 60% and decay times in excess of 2 ms. Moreover, as powderous phosphors typically require stable matrices to be hosted in, we investigated low melting, lead- and fluoride-free glasses for their capability to accommodate the phosphor and yet retain its optical properties. In these, we even observed an increase of the quantum efficiencies of up to 70% at decay times approaching 3 ms. Finally, we characterized the thermal quenching behavior, which showed a clear advantage of the phosphors in glassy matrices. KW - Rare earth phosphors KW - Energy transfer KW - Luminescent glasses and glazes PY - 2016 DO - https://doi.org/10.1016/j.jlumin.2015.05.005 SN - 0022-2313 SN - 1872-7883 VL - 170 SP - 387 EP - 394 PB - Elsevier B.V. CY - Amsterdam AN - OPUS4-35131 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Grengg, C. A1 - Koraimann, G. A1 - Ukrainczyk, N. A1 - Rudic, O. A1 - Luschnig, S. A1 - Gluth, Gregor A1 - Radtke, Martin A1 - Dietzel, M. A1 - Mittermayr, F. T1 - Cu- and Zn-doped alkali activated mortar – Properties and durability in (bio)chemically aggressive wastewater environments N2 - Metakaolin-based alkali activated mortars (AAM) - with and without CuSO4·5H2O and ZnO addition (mass ratio Mn+/solid binder 0.08% to 1.7%) - were casted and exposed within an extensive long-term field campaign over the period of 20 months to a sewer basin, strongly affected by biogenic acid corrosion. (Un-)exposed AAM were tested regarding their physicochemical and microstructural properties, bioreceptivity and overall durability. Metal addition led to a retarding effect during alkali-activation reaction, as well as to an increase in open porosity of up to 3.0% and corresponding lower compressive strength of up to 10.9%. Reduced microbial colonization and diversity were observed on AAM with Cu, while Zn addition led to increased biodiversity. We propose that the observed higher durability of Cu-doped AAM is due to antibacterial effects and associated reduction of biogenic acid production, superseding overall negative effects of metal-dosage on physical material properties. Observed lower durability of Zn-doped AAM was related to combined negative physicochemical and microbial effects. KW - Microbially induced corrosion KW - Alkali-activated materials KW - Biogenic acid corrosion KW - Biogene Schwefelsäurekorrosion KW - MIC PY - 2021 DO - https://doi.org/10.1016/j.cemconres.2021.106541 SN - 0008-8846 VL - 149 SP - 1 EP - 15 PB - Elsevier CY - Oxford AN - OPUS4-53070 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - von Bohlen, A. A1 - Hergenröder, R. A1 - Sternemann, C. A1 - Paulus, M. A1 - Radtke, Martin A1 - Riesemeier, Heinrich T1 - Wavelenght Dispersive Synchrotron Microprobe Used for Material Analysis N2 - Synchrotron radiation (SR) has been used in recent years as an excellent excitation source for X-ray fluorescence spectrometry. SR offers, in contrast to conventional X-ray sources, highly brilliant polychromatic, polarized radiation with which micro-domain X-ray fluorescence spectrometry becomes possible. A feasibility study of utility, conducted at BESSY (Berlin) and at DELTA (Dortmund), both synchrotron facilities of the third generation, to evaluate the use of wavelength dispersive X-ray fluorescence spectrometry in combination with synchrotron radiation is presented. First results for material analysis, obtained by combining the synchrotron radiation and a commercially available spectrometer commonly attached to a scanning electron microscope, are presented. The spectrometer, of the linear type, uses curved focusing Bragg-crystals of the Johann type which leads to a high spectral resolution up to 3 eV. Examples of micro-domain analyses are presented and compared with those obtained by synchrotron radiation induced energy dispersive X-ray fluorescence. KW - Synchrotron radiation KW - WDXRF KW - EDXRF KW - Micro analysis KW - Material analysis PY - 2005 DO - https://doi.org/10.1081/CI-200048048 SN - 1073-9149 SN - 1525-6030 VL - 33 IS - 2 SP - 137 EP - 150 PB - Dekker CY - New York, NY AN - OPUS4-14235 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gauert, C. A1 - Schannor, M. A1 - Hecht, L. A1 - Radtke, Martin A1 - Reinholz, Uwe T1 - A comparison of in situ analytical methods for trace element measurement in gold samples from various South African gold deposits N2 - Trace element concentrations in gold grains from various geological units in South Africa were measured in situ by field emission-electron probe microanalysis (FE-EPMA), laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) and synchrotron micro X-ray fluorescence spectroscopy (SR-µ-XRF). This study assesses the accuracy, precision and detection limits of these mostly non-destructive analytical methods using certified reference materials and discusses their application in natural sample measurement. FE-EPMA point analyses yielded reproducible and discernible concentrations for Au and trace concentrations of S, Cu, Ti, Hg, Fe and Ni, with detection limits well below the actual concentrations in the gold. LA-ICP-MS analyses required larger gold particles (> 60 µm) to avoid contamination during measurement. Elements that measured above detection limits included Ag, Cu, Ti, Fe, Pt, Pd, Mn, Cr, Ni, Sn, Hg, Pb, As and Te, which can be used for geochemical characterisation and gold fingerprinting. Although LA-ICP-MS measurements had lower detection limits, precision was lower than FE-EPMA and SR-µ-XRF. The higher variability in absolute values measured by LA-ICP-MS, possibly due to micro-inclusions, had to be critically assessed. Non-destructive point analyses of gold alloys by SR-µ-XRF revealed Ag, Fe, Cu, Ni, Pb, Ti, Sb, U, Cr, Co, As, Y and Zr in the various gold samples. Detection limits were mostly lower than those for elements measured by FE-EPMA, but higher than those for elements measured by LA-ICP-MS. N2 - Les concentrations en éléments traces de grains d'or provenant de différentes unités géologiques d'Afrique du Sud ont été mesurées in situ par microsonde électronique à émission de champ (FE-EPMA), spectrométrie de masse couplée à une source plasma et un système d'ablation laser (LA-ICP-MS) et micro spectroscopie de fluorescence des rayons X au Synchrotron (SR-µ-XRF). Cette étude évalue l'exactitude, la précision et les limites de détection de ces méthodes d'analyse pour la plupart non-destructives en utilisant des matériaux de référence certifiés, et discute de leur application dans les mesures sur échantillon naturel. Les points d'analyses FE-EPMA ont fournis des concentrations reproductibles et discernables pour l'Au et des concentrations en traces de S, Cu, Ti, Hg, Fe et Ni, avec des limites de détection bien inférieures aux concentrations réelles dans l'or. Les analyses LA-ICP-MS ont nécessitées des particules d'or de plus grande taille (> 60 µm) pour éviter toute contamination pendant la mesure. Les éléments mesurés au-dessus des limites de détection inclus Ag, Cu, Ti, Fe, Pt, Pd, Mn, Cr, Ni, Sn, Hg, Pb, A et Te, qui peuvent être utilisés pour les caractérisations géochimique et le «fingerprinting» de l'or. Bien que les mesures LA-ICP-MS aient des limites de détection plus basses, la précision est inférieure par rapport à celles de la microsonde FE et de la SR-µ-XRF. La plus grande variabilité des valeurs absolues mesurées par LA-ICP-MS, probablement reliée à la présence de micro-inclusions, a du être évaluée de manière critique. Les points d'analyse non-destructifs des alliages d'or par SR-µ-XRF ont révélés la présence de Ag, Fe, Cu, Ni, Pb, Ti, Sb, U, Cr, Co, As, Y et Zr dans les différents échantillons. Les limites de détection ont été pour la plupart inférieures à celles des éléments mesurés par FE-EPMA, mais supérieures à celles des éléments mesurés par LA-ICP-MS. KW - Trace elements KW - Gold KW - FE-EPMA KW - LA-ICP-MS KW - SR-µ-XRF KW - Precision KW - Précision KW - Comparison of techniques KW - Éléments traces PY - 2016 DO - https://doi.org/10.1111/j.1751-908X.2015.00362.x SN - 1639-4488 SN - 1751-908X VL - 40 IS - 2 SP - 267 EP - 289 PB - Blackwell CY - Oxford AN - OPUS4-34882 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Menzel, M. A1 - Scharf, O. A1 - Novak, S. A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Hischenhuber, P. A1 - Buzanich, Günter A1 - Meyer, A. A1 - Lopez, V. A1 - McIntosh, K. A1 - Streli, C. A1 - Havrilla, G. A1 - Fittschen, U. T1 - Shading in TXRF: calculations and experimental validation using a color X-ray camera N2 - Absorption effects in total reflection X-ray fluorescence (TXRF) analysis are important to consider, especially if external calibration is to be applied. With a color X-ray camera (CXC), that enables spatially and energy resolved XRF analysis, the absorption of the primary beam was directly visualized for mL-droplets and an array of pL-droplets printed on a Si-wafer with drop-on-demand technology. As expected, deposits that are hit by the primary beam first shade subsequent droplets, leading to a diminished XRF signal. This shading effect was quantified with enhanced precision making use of sub-pixel analysis that improves the spatial resolution of the camera. The measured absorption was compared to simulated results using three different model calculations. It was found they match very well (average deviation < 10%). Thus errors in quantification due to absorption effects can be accounted for in a more accurate manner. KW - absorption KW - X-ray Fluorescence analysis PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-359000 DO - https://doi.org/10.1039/C5JA00127G IS - 10 SP - 2184 EP - 2193 PB - Royal Society of Chemistry CY - Cambridge AN - OPUS4-35900 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -