TY - JOUR A1 - Merchel, S. A1 - Bremser, Wolfram A1 - Alfimov, V. A1 - Arnold, M. A1 - Aumaître, G. A1 - Benedetti, L. A1 - Bourlès, D.L. A1 - Caffee, M. A1 - Fifield, L.K. A1 - Finkel, R.C. A1 - Freeman, S.P.H.T. A1 - Martschini, M. A1 - Matsushi, Y. A1 - Rood, D.H. A1 - Sasa, K. A1 - Steier, P. A1 - Takahashi, T. A1 - Tamari, M. A1 - Tims, S.G. A1 - Tosaki, Y. A1 - Wilken, K. M. A1 - Xu, S. T1 - Ultra-trace analysis of 36Cl by accelerator mass spectrometry: an interlaboratory study N2 - A first international 36Cl interlaboratory comparison has been initiated. Evaluation of the final results of the eight participating accelerator mass spectrometry (AMS) laboratories on three synthetic AgCl samples with 36Cl/Cl ratios at the 10-11, 10-12, and 10-13 level shows no difference in the sense of simple statistical significance. However, more detailed statistical analyses demonstrate certain interlaboratory bias and underestimation of uncertainties by some laboratories. Following subsequent remeasurement and reanalysis of the data from some AMS facilities, the round-robin data indicate that 36Cl/Cl data from two individual AMS laboratories can differ by up to 17%. Thus, the demand for further work on harmonising the 36Cl-system on a worldwide scale and enlarging the improvement of measurements is obvious. KW - Accelerator mass spectrometry KW - Long-lived radionuclides KW - Cosmogenic nuclides KW - Exposure dating PY - 2011 DO - https://doi.org/10.1007/s00216-011-4979-2 SN - 1618-2642 SN - 1618-2650 VL - 400 IS - 9 SP - 3125 EP - 3132 PB - Springer CY - Berlin AN - OPUS4-23676 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Blasón Gonzalez, Sergio A1 - Werner, Tiago A1 - Kruse, Julius A1 - Madia, Mauro A1 - Miarka, P. A1 - Seitl, S. A1 - Benedetti, M. T1 - Determination of fatigue crack growth in the near-threshold regime using small-scale specimens N2 - A complete description of the experimental procedure for characterizing the intrinsic fatigue crack propagation threshold (ΔKth,eff) as well as the fatigue crack growth rate (FCGR) in the near-threshold regime using small-scale specimens is presented. A comparative study is carried out on the high strength steel S960QL considering different single edge notch bend (SENB) specimen geometries. On one hand, the reference dimensions of 6 mm thickness (B) and 19 mm width (W) are analysed and referred to as conventional specimens. On the other hand, small-scale specimens with B = 3 mm and W = 4 and 6 mm are also considered. Several loading configurations (3-, 4- and 8-point bending) are used and a load ratio R = 0.8 is applied to avoid crack closure effects. The direct current potential drop (DCPD) technique is used to monitor the crack length. The reduced dimensions of the small-scale specimens imply the necessity of implementing a modified testing procedure compared to the recommendations of current standards for the generation of FCGR data. The results show a good agreement between tests conducted on different specimen sizes, which opens new perspectives in the use of small-scale specimens for characterizing the fatigue crack growth properties in metallic materials. Recommendations and limitations of the procedure are provided and discussed. KW - Fatigue crack growth KW - Small-scale specimens KW - Intrinsic fatigue propagation threshold KW - Near-threshold regime KW - High-strength steel KW - Alternative test procedure PY - 2022 DO - https://doi.org/10.1016/j.tafmec.2021.103224 SN - 0167-8442 VL - 118 SP - 1 EP - 12 PB - Elsevier CY - Amsterdam AN - OPUS4-54209 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -