TY - JOUR A1 - Jacobs, R. A1 - Meneve, J. A1 - Dyson, G. A1 - Teer, D. G. A1 - Jennett, N. M. A1 - Harris, P. A1 - von Stebut, J. A1 - Comte, C. A1 - Feuchter, P. A1 - Cavaleiro, A. A1 - Ronkainen, H. A1 - Holmberg, K. A1 - Beck, Uwe A1 - Reiners, Georg A1 - Ingelbrecht, C. D. T1 - A certified reference material for the scratch test JF - Surface and coatings technology N2 - Adhesion and other mechanical behaviour of coatings is at present routinely tested in industry and research organisations using the scratch test. The test has been the subject of a European Standard prEN 1071-3:2000 established by the European Standards Committee CEN TC184 WG5. A previous European project on the development and validation of test methods for thin hard coatings—FASTE—revealed that uncertainties in the Rockwell C stylus tip shape represent a major source of error for the scratch-test method. Therefore a follow-up project—REMAST—was started to develop and certify a reference material as a quality control tool for the testing and qualification of scratch-test instruments. In addition, a considerable effort was devoted to improve the scratch stylus manufacturing process. This paper presents the results of the REMAST project. During a feasibility study, two candidate materials—titanium nitride (TiN) and diamond-like carbon (DLC) coatings both on high speed steel substrates—were evaluated. Because of the lower sensitivity to styli tip shape variations and higher data scatter observed for the TiN coating, DLC was chosen as the reference material to be certified. One thousand samples were produced, as well as qualified styli to carry out the certification campaign, including homogeneity and stability testing. Nine independent laboratories were involved in the certification exercise, and the data were statistically analysed to obtain the certified critical load values and their uncertainty ranges. A certified reference material BCR-692 is available for verification purposes. This presents three repeatable failure events at certified critical load intervals and can provide a good indication of overall scratch-test instrument performance, including stylus condition and calibration. It is also useful as a diagnostic tool, providing a means of sensitive monitoring of machine and stylus performance over extended periods. Considerable improvement of the quality of scratch styli was achieved by the strict control of all manufacturing steps. KW - Adhesion KW - Scratch test KW - Certified reference material PY - 2003 DO - https://doi.org/10.1016/S0257-8972(03)00470-5 SN - 0257-8972 VL - 174-175 SP - 1008 EP - 1013 PB - Elsevier Science CY - Lausanne AN - OPUS4-25435 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ruhe, L. A1 - Ickert, Stefanie A1 - Beck, S. A1 - Linscheid, M. W. T1 - A new strategy for metal labeling of glycan structures in antibodies JF - Anal. Bioanal. Chem. N2 - Quantitative analysis of complex proteins is a challenging task in modern bioanalytical chemistry. Commonly available isotope labels are still suffering from limitations and drawbacks, whereas new metal labels open numerous possibilities in mass spectrometric analyses. In this work, we have developed a newmetal labeling strategy to tag glycan structures of proteins, more particularly antibodies. The oligosaccharide glycans were selectively trimmed to the last N-acetylglucosamine to which an artificial azide containing galactose residue was bound. This azide can be used for subsequent cycloaddition of an alkyne. Therefore, we developed a lanthanide-containing macrocyclic reagent to selectively connect to this azido galactose. In summary, the glycan structures of an antibody can be labeled with a metal functionality using this approach. Furthermore, the functionality of the antibodies can be fully maintained by labeling the Fc glycans instead of using labeling reagents that target amino or thiol groups. This approach enables the possibility of using elemental, besides molecular mass spectrometry, for quantitative analyses or imaging experiments of antibodies in complex biological samples. KW - Antibody KW - Metal labeling KW - Glycans KW - DOTA KW - Lanthanide PY - 2018 DO - https://doi.org/10.1007/s00216-017-0683-1 SN - 1618-2650 SN - 1618-2642 VL - 410 IS - 1 SP - 21 EP - 25 PB - Springer AN - OPUS4-44000 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bovtun, Viktor Petrovic A1 - Döring, Joachim A1 - Wegener, M. A1 - Bartusch, Jürgen A1 - Beck, Uwe A1 - Erhard, Anton A1 - Borisov, V. T1 - Air-coupled ultrasonic applications of ferroelectrets JF - Ferroelectrics KW - Air-coupled ultrasonics KW - Non-contact transducers KW - Ferroelectrets KW - Electromechanical properties PY - 2008 DO - https://doi.org/10.1080/00150190802380243 SN - 0015-0193 SN - 1563-5112 VL - 370 IS - 1 SP - 11 EP - 17 PB - Taylor & Francis CY - New York, NY AN - OPUS4-20924 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Winchester, M. R. A1 - Beck, Uwe T1 - Availability of layered certified reference materials for industrial application of glow discharge spectrometric depth profiling JF - Surface and interface analysis N2 - Owing primarily to speed, low cost and ease of use relative to competing surface analysis techniques, glow discharge spectrometry (GDS) has become an economically important depth profiling method for certain niche industries in Europe and Japan. For the industrial application of this method, layered certified reference materials (CRMs) are needed to ensure accuracy, as well as comparability between individual users. A survey of existing CRMs has been conducted to evaluate the availability of layered CRMs with appropriate characteristics. No materials with the desirable characteristics necessary for efficient implementation were found. These results indicate a need for the production of new layered CRMs. The survey was conducted by an advisory group assembled as part of the activities of the Glow Discharge Spectrometry Subcommittee (ISO TC201/SC8) associated with the ISO Technical Committee on Surface Chemical Analysis (ISO TC201). KW - Certified reference materials KW - Depth profiling KW - Glow discharge spectrometry KW - ISO PY - 1999 DO - https://doi.org/10.1002/(SICI)1096-9918(199910)27:10<930::AID-SIA653>3.0.CO;2-D SN - 0142-2421 SN - 1096-9918 VL - 27 IS - 10 SP - 930 EP - 935 PB - Wiley CY - Chichester AN - OPUS4-25571 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ickert, Stefanie A1 - Hofmann, J. A1 - Riedel, Jens A1 - Beck, S. A1 - Pagel, K. A1 - Linscheid, M. W. T1 - Charge-induced geometrical reorganization of DNA oligonucleotides studied by tandem mass spectrometry and ion mobility JF - European Journal of Mass Spectrometry N2 - Mass spectrometry is applied as a tool for the elucidation of molecular structures. This premises that gas-phase structures reflect the original geometry of the analytes, while it requires a thorough understanding and investigation of the forces controlling and affecting the gas-phase structures. However, only little is known about conformational changes of oligonucleotides in the gas phase. In this study, a series of multiply charged DNA oligonucleotides (n¼15–40) has been subjected to a comprehensive tandem mass spectrometric study to unravel transitions between different ionic gas-phase structures. The nucleobase sequence and the chain length were varied to gain insights into their influence on the geometrical oligonucleotide organization. Altogether, 23 oligonucleotides were analyzed using collision-induced fragmentation. All sequences showed comparable correlation regarding the characteristic collision energy. This value that is also a measure for stability, strongly correlates with the net charge density of the precursor ions. With decreasing charge of the oligonucleotides, an increase in the fragmentation energy was observed. At a distinct charge density, a deviation from linearity was observed for all studied species, indicating a structural reorganization. To corroborate the proposed geometrical change, collisional cross-sections of the oligonucleotides at different charge states were determined using ion mobility-mass spectrometry. The results clearly indicate that an increase in charge density and thus Coulomb repulsion results in the transition from a folded, compact form to elongated structures of the precursor ions. Our data show this structural transition to depend mainly on the charge density, whereas sequence and size do not have an influence. KW - Ion mobility KW - Collision-induced dissociation KW - Mass spectrometry KW - Oligonucleotide KW - Fragmentation KW - Tandem-MS PY - 2018 DO - https://doi.org/10.1177/1469066717746896 SN - 1469-0667 SN - 1751-6838 VL - 24 IS - 2 SP - 225 EP - 230 PB - Sage AN - OPUS4-44429 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schwarz, G. A1 - Beck, S. A1 - Weller, Michael G. A1 - Linscheid, M.W. T1 - Comparison of the fragmentation behavior of differentially metal-coded affinity tag (MeCAT)-labeled peptides JF - Journal of mass spectrometry PY - 2012 DO - https://doi.org/10.1002/jms.3036 SN - 1076-5174 SN - 1096-9888 VL - 47 IS - 7 SP - 885 EP - 889 PB - Wiley CY - Chichester AN - OPUS4-27436 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ickert, Stefanie A1 - Schwaar, Timm A1 - Springer, A. A1 - Grabarics, M. A1 - Riedel, Jens A1 - Beck, S. A1 - Pagel, K. A1 - Linscheid, M. W. T1 - Comparison of the fragmentation behavior of DNA and LNA single strands and duplexes JF - Journal of Mass Spectrometry N2 - DNA and locked nucleic acid (LNA) were characterized as single strands, as well as double stranded DNA-DNA duplexes and DNA-LNA hybrids using tandem mass spectrometry with collision-induced dissociation. Additionally, ion mobility spectrometry was carried out on selected species. Oligonucleotide duplexes of different sequences – bearing mismatch positions and abasic sites of complementary DNA 15-mers – were investigated to unravel general trends in their stability in the gas phase. Single stranded LNA oligonucleotides were also investigated with respect to their gas phase behavior and fragmentation upon collision-induced dissociation. In contrast to the collision-induced dissociation of DNA, almost no base loss was observed for LNAs. Here, backbone cleavages were the dominant dissociation pathways. This finding was further underlined by the need for higher activation energies. Base losses from the LNA strand were also absent in fragmentation experiments of the investigated DNA-LNA hybrid duplexes. While DNA-DNA duplexes dissociated easily into single stranded fragments, the high stability of DNA-LNA hybrids resulted in predominant fragmentation of the DNA part rather than the LNA, while base losses were only observed from the DNA single strand of the hybrid. KW - Oligonucleotide fragmentation KW - Locked nucleic acids KW - Collision induced dissociation (CID) KW - Double strands KW - Ion mobility spectrometry PY - 2019 DO - https://doi.org/10.1002/jms.4344 VL - 54 IS - 5 SP - 402 EP - 411 PB - Wiley AN - OPUS4-47485 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Trog, S. A1 - El-Khatib, Ahmed A1 - Beck, S. A1 - Makowski, M. A1 - Jakubowski, Norbert A1 - Linscheid, M. T1 - Complementarity of molecular and elemental mass spectrometric imaging of Gadovist™ in mouse tissues JF - Elemental and Molecular Imaging by LA-ICP-MS N2 - Drug biodistribution analyses can be considered a key issue in pharmaceutical discovery and development. Here, mass spectrometric imaging can be employed as a powerful tool to investigate distributions of drug compounds in biologically and medically relevant tissue sections. Both matrix-assisted laser desorption ionization–mass spectrometric imaging as molecular method and laser ablation inductively coupled plasma–mass spectrometric imaging as elemental detection method were applied to determine drug distributions in tissue thin sections. Several mouse organs including the heart, kidney, liver, and brain were analyzed with regard to distribution of Gadovist™, a gadolinium-based contrast agent already approved for clinical investigation. This work demonstrated the successful detection and localization of Gadovist™ in several organs. Furthermore, the results gave evidence that gadolinium-based contrast agents in general can be well analyzed by mass spectrometric imaging methods. In conclusion, the combined application of molecular and elemental mass spectrometry could complement each other and thus confirm analytical results or provide additional information. KW - Laser ablation inductively coupled plasma–mass spectrometry imaging (LA-ICP-MSI) KW - Gadolinium-based contrast agents (GBCAs) KW - Matrix-assisted laser desorption ionization–mass spectrometry imaging (MALDI-MSI) PY - 2019 DO - https://doi.org/10.1007/s00216-018-1477-9 SN - 1618-2642 SN - 1618-2650 VL - 411 IS - 3 SP - 629 EP - 637 PB - Springer AN - OPUS4-47371 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ruhe, L. A1 - Ickert, Stefanie A1 - Hochkirch, U. A1 - Hofmann, J. A1 - Beck, S. A1 - Thomale, J. A1 - Linscheid, M. W. T1 - Comprehensive molecular characterization of a cisplatin-specific monoclonal antibody JF - Molecular Pharmaceutics N2 - Despite their immense and rapidly increasing importance as analytical tools or therapeutic drugs, the detailed structural features of particular monoclonal antibodies are widely unknown. Here, an antibody already in use for diagnostic purposes and for molecular dosimetry studies in cancer therapy with very high affinity and specificity for cisplatin-induced DNA modifications was studied extensively. The molecular structure and modifications as well as the antigen specificity were investigated mainly by mass spectrometry. Using nano electrospray ionization mass spectrometry, it was possible to characterize the antibody in its native state. Tandem-MS experiments not only revealed specific fragments but also gave information on the molecular structure. The detailed primary structure was further elucidated by proteolytic treatment with a selection of enzymes and high resolution tandem-MS. The data were validated by comparison with known antibody sequences. Then, the complex glycan structures bound to the antibody were characterized in all detail. The Fc-bound oligosaccharides were released enzymatically and studied by matrix-assisted laser desorption/ionization mass spectrometry. Overall 16 different major glycan structures were identified. The binding specificity of the antibody was investigated by applying synthetic single and double stranded DNA oligomers harboring distinct Pt adducts. The antibody− antigen complexes were analyzed by mass spectrometry under native conditions. The stability of the complex with double stranded DNA was also investigated. KW - Antibody KW - Native MS KW - Cisplatin KW - PTM PY - 2017 DO - https://doi.org/10.1021/acs.molpharmaceut.7b00575 SN - 1543-8384 SN - 1543-8392 VL - 14 IS - 12 SP - 4454 EP - 4461 AN - OPUS4-43997 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Le, Quynh Hoa A1 - Bäßler, Ralph A1 - Bettge, Dirk A1 - Buggisch, E. A1 - Schiller, Bernadette Nicole A1 - Beck, M. T1 - Corrosion Study on Wellbore Materials for the CO2 Injection Process JF - Processes N2 - For reliability and safety issues of injection wells, corrosion resistance of materials used needs to be determined. Herein, representative low-cost materials, including carbon steel X70/1.8977 and low alloyed steel 1.7225, were embedded in mortar to mimic the realistic casing-mortar interface. Two types of cement were investigated: (1) Dyckerhoff Variodur commercial Portland cement, representing a highly acidic resistant cement and (2) Wollastonite, which can react with CO2 and become stable under a CO2 stream due to the carbonation process. Exposure tests were performed under 10 MPa and at 333 K in artificial aquifer fluid for up to 20 weeks, revealing crevice corrosion and uniform corrosion instead of expected pitting corrosion. To clarify the role of cement, simulated pore water was made by dispersing cement powder in aquifer fluid and used as a solution to expose steels. Surface analysis, accompanied by element mapping on exposed specimens and their crosssections, was carried out to trace the chloride intrusion and corrosion process that followed. KW - Carbon capture storage KW - CCS KW - Carbon dioxide KW - Corrosion KW - Carbon steel KW - Aquifer fluid KW - Cement KW - Casing KW - Pitting PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-519774 DO - https://doi.org/10.3390/pr9010115 SN - 2227-9717 VL - 9 IS - 1 SP - 115 PB - MDPI CY - Basel AN - OPUS4-51977 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -