TY - CONF A1 - Laquai, René A1 - Schaupp, Thomas A1 - Müller, Bernd R. A1 - Griesche, Axel A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Kannengießer, Thomas A1 - Bruno, Giovanni T1 - 3D Crack analysis in hydrogen charged lean duplex stainless steel with synchrotron refraction CT N2 - Hydrogen in metals can cause a degradation of the mechanical properties, the so-called hydrogen embrittlement. In combination with internal stresses, hydrogen assisted cracking (HAC) can occur. This phenomenon is not completely understood yet. To better characterise the cracking behaviour, it is important to gain information about the evolution of the 3D crack network. For this purpose samples of lean duplex stainless steel were loaded with hydrogen by means of electrochemical charging and investigated by means of synchrotron refraction CT and SEM fractography after uniaxial tensile loading. Synchrotron refraction CT is an analyser-based imaging (ABI) technique. It uses a Si (111) single crystal as analyser, which is placed into the beam path between sample and detector. According to Bragg’s law only incident x-rays within a narrow range around the Bragg-angle are diffracted from the analyser into the detector. Hence, the analyser acts as an angular filter for the transmitted beam. This filtering allows to turn the refraction and scattering of x-rays into image contrast. Refraction occurs at all interfaces, where the density of the material changes and is more sensitive to density changes than the attenuation. Therefore, it is possible to detect smaller cracks than with classical x-ray imaging techniques, like CT, with comparable spacial resolution. It also visualises the 3D structure of the cracks and gains quantitative information about their morphology and distribution. Since cracks introduced by HAC are usually very small and have a small opening displacement, synchrotron refraction CT is expected to be well suited for imaging this cracking mechanism and can be a valuable tool to characterise the formation and the evolution of a 3D crack network. T2 - WCNDT 2016 CY - München, Germany DA - 13.06.2016 KW - X-ray refraction KW - Computed tomography KW - Hydrogen assisted cracking KW - Duplex stainless steel PY - 2016 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-366481 SN - 978-3-940283-78-8 VL - BB 158 SP - Tu.4.B.3, 1 EP - 9 AN - OPUS4-36648 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, Axel A1 - Becker, Roland A1 - Braun, Ulrike A1 - Dorgerloh, Ute T1 - Einfluss der Alterung auf das Sorptionsverhalten von Mikroplastik, eine Laborstudie mit BTEX und Etherverbindungen N2 - Die Präsenz von Mikroplastik in aquatischen Ökosystemen ist ein globales Problem und steht zunehmend im Fokus der Öffentlichkeit. In mehreren Studien konnten Anreicherungen hydrophober, organischer Schadstoffe an MP nachgewiesen werden. Der Einfluss des Alterungszustandes der MP-Partikel auf das Sorptionsverhalten von hydrophoben organischen Substanzen ist nicht hinreichend geklärt. Ziel der vorliegenden Arbeit war die Untersuchung des Sorptionsverhaltens von Schadstoffen mit Bedeutung für limnische Gewässer an künstlich gealterten Partikeln relevanter Polymere. Das Modell verwendete die Aromaten Benzol, Toluol, Ethylbenzol und Xylol (BTEX) sowie Etherverbindungen. Diese Substanzen sind oder waren Bestandteile in unterschiedlichen Kraftstoffen und finden sich daher in vielen aquatischen Ökosystemen weltweit. Als Sorbentien kamen teilkristallines Polypropylen (PP) und amorphes Polystyrol (PS) in Form von Industriepellets zum Einsatz. Die Pellets wurden jeweils sowohl unbehandelt als auch mittels UV-Bestrahlung künstlich gealtert verwendet und mikroskopisch sowie mittels XPS, FTIR und DSC charakterisiert. Die Alterung führte bei PS zu einer verringerten Sorptionskapazität, während bei PP keine Veränderung im Sorptionsverhalten beobachtet wurde. T2 - Wasser 2017 - Jahrestagung der Wasserchemischen Gesellschaft CY - Donaueschingen, Germany DA - 22.05.2017 KW - Mikroplastik KW - Organische Schadstoffe KW - Sorption KW - Polypropylen Polystyrol PY - 2017 SN - 978-3-947197-01-9 SP - 1 EP - 606 PB - Gesellschaft Dt. Chemiker AN - OPUS4-40447 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hentschel, Manfred P. A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Müller, Bernd R. A1 - Schors, Jörg T1 - Das Anwendungspotential der Röntgen-Topographie vom Mikroriss bis zur Gepäckprüfung T2 - DGZfP-Jahrestagung 2007 CY - Fürth, Deutschland DA - 2007-05-14 KW - CFK KW - Bildgebende Röntgenverfahren KW - Röntgen-Topographie und -Streuung KW - Keramik KW - Explosivstoffe KW - Ermüdungsrisse PY - 2007 SN - 978-3-931381-98-1 SP - 1 EP - 9 PB - DGZfP CY - Berlin AN - OPUS4-15799 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, Bernd R. A1 - Lange, Axel A1 - Harwardt, Michael A1 - Hentschel, Manfred P. A1 - Illerhaus, Bernhard A1 - Goebbels, Jürgen A1 - Bamberg, J. A1 - Heutling, F. T1 - X-Ray Refraction Topography and Computed Tomography for NDE of Lightweight Materials T2 - 9th European Conference on NDT CY - Berlin, Germany DA - 2006-09-25 KW - Synchrotron Refraction CT KW - MMC KW - Bragg-Magnification PY - 2006 SN - 3-931381-86-2 SP - 1(?) EP - 9(?) PB - European Federation for Non-Destructive Testing CY - Berlin AN - OPUS4-13703 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kupsch, Andreas A1 - Hentschel, Manfred P. A1 - Lange, Axel A1 - Müller, Bernd R. T1 - X-ray dark field imaging N2 - A new kind of enhanced contrast X-ray imaging of weakly absorbing materials in dark field mode is presented. Samples such as plastics and biological tissue are a perpetual challenge for radiographic imaging. Recent innovative approaches such as Diffraction Enhanced Imaging (DEI), “phase contrast”, grating interferometry (Talbot-Lau), or Refraction Enhanced Imaging (REI) have in common that they yield enhanced contrast based on deflected X-rays. Here, we introduce a REI modification, which works with a slightly bent single crystal reflecting in Bragg geometry. The samples are placed upstream of the thin crystal within a parallel synchrotron beam. The crystal’s curvature creates a dark-field stripe in the transmission image, similar to the inverse of a Darwin-Prins rocking curve of plane crystals. The reflection condition is met better or worse as a steady function of incidence position. Refracted beam portions of sample interfaces appear bright on black stripes. The entire image is finally synthesized by multiple dark-field stripes. The technique is an alternative to the mentioned techniques. We demonstrate the technique’s advantage by examples of biological and technical microstructures. T2 - ECNDT 2014 - 11th European conference on non-destructive testing CY - Prague, Czech Republic DA - 06.10.2014 KW - X-ray refraction KW - Refraction enhanced imaging (REI) KW - Phase contrast KW - Radiology KW - Soft matter radiography PY - 2014 SN - 978-80-214-5018-9 SP - 1 EP - 7 AN - OPUS4-31971 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lange, Axel A1 - Müller, Bernd R. A1 - Hentschel, Manfred P. A1 - Kupsch, Andreas T1 - Korrektur des Hinterleuchtens an CT-Synchrotrondaten N2 - In den unterschiedlichsten Methoden der Computertomographie tritt häufig ein diffuses Untergrundsignal in den Einzelprojektionen auf: im Falle der Parallelstrahl-CT mit Synchrotronstrahlung handelt es sich um ein Hinterleuchten durch den Fluoreszenzschirm, der vor der CCD-Kamera angeordnet ist. Dieses Hinterleuchten unterscheidet sich von dem bekannten Nachleuchten (Phosphoreszenz) durch zeitliche Konstanz. Hier äußert sich das Hinterleuchten als Modulation der projizierten Masse und somit als Funktion der Phase (Projektionswinkel) und des Aspektverhältnisses des Objektes. Der Einfluss des Hinterleuchtens ist abhängig von der Größe des von der Probe abgeschatteten Detektorbereiches und des Objektumfangs (Dynamik). Dies hat u.a. zur Folge, dass Abweichungen vom Absorptionsgesetz auftreten, die umso stärker ausgeprägt sind, je weniger Detektorfläche das Objekt abdeckt und je stärker das Objekt schwächt. Dabei können Aufhärtungseffekte wegen der monochromatischen Strahlung ausgeschlossen werden. Mit Referenzmessungen und einem isotropen, homogenen Ansatz, der diese Abweichung als Hinterleuchten beschreibt, lassen sich die auftretenden Fehler deutlich verringern. T2 - DGZfP-Jahrestagung 2011 CY - Bremen, Germany DA - 30.05.2011 KW - Hinterleuchten KW - Detektor KW - Fluoreszenzschirm KW - Synchrotron-Radiographie KW - Computer-Tomographie PY - 2011 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-250038 SN - 978-3-940283-33-7 IS - DGZfP-BB 127 (P6) SP - 1 EP - 8 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) AN - OPUS4-25003 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, Bernd R. A1 - Lange, Axel A1 - Harwardt, Michael A1 - Hentschel, Manfred P. T1 - Synchrotron-Refraktions-Computer-Tomographie - EIne neue Methode zur Erkennung von Grenzflächen T2 - DGZfP-Jahrestagung 2009 CY - Münster, Deutschland DA - 2009-05-18 KW - Synchrotronstrahlung KW - Refraktion KW - Diffraktion KW - Kleinwinkelstreuung KW - Materialcharakterisierung KW - Zerstörungsfrei PY - 2009 SN - 978-3-940283-16-0 IS - DGZfP-BB 115 (Di.1.A.1) SP - 1 EP - 11 AN - OPUS4-20609 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, Bernd R. A1 - Hentschel, Manfred P. A1 - Harbich, Karl-Wolfram A1 - Lange, Axel A1 - Schors, Jörg T1 - Charakterisierung von Mikroschäden in polymeren Faserkompositen mittels Röntgen-Refraktions-Topography T2 - Jahrestagung Zerstörungsfreie Materialprüfung 2001 CY - Berlin, Deutschland DA - 2001-05-21 PY - 2001 UR - http://www.ndt.net/article/dgzfp01/papers/p49/p49.htm N1 - Serientitel: Berichtsband / Deutsche Gesellschaft für zerstörungsfreie Prüfung e. V. – Series title: Berichtsband / Deutsche Gesellschaft für zerstörungsfreie Prüfung e. V. IS - 75-CD PB - DGZfP CY - Berlin AN - OPUS4-1298 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, Bernd R. A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Kupsch, Andreas ED - Kastner, J. T1 - A comfortable procedure for correcting X-ray detector backlight T2 - Conference on industrial computed tomography CY - Wels, Austria DA - 2012-09-19 KW - X-ray detector backlighting KW - Radiography KW - Fluorescent screen KW - Diffuse background KW - Computed tomography PY - 2012 SN - 978-3-8440-1281-1 SN - 1610-4773 SP - 151 EP - 157 PB - Shaker CY - Aachen AN - OPUS4-26768 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, Bernd R. A1 - Harwardt, Michael A1 - Hentschel, Manfred P. A1 - Lange, Axel A1 - Alpern, P. A1 - Tilgner, R. T1 - Sichere Automobil Elektronik durch nanogenaues Synchrotron-Prüfverfahren T2 - DGZfP Jahrestagung 2007 CY - Fürth, Deutschland DA - 2007-05-14 KW - Synchrotron Laue Contrast Radiography PY - 2007 SN - 978-3-931381-98-1 SP - 1 EP - 8 PB - DGZfP CY - Berlin AN - OPUS4-15837 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hentschel, Manfred P. A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Müller, Bernd R. T1 - Refraktions-Interface-Radiographie N2 - Nanoskalige Strukturen und Grenzflächen bestimmen zunehmend die Funktionalität moderner Materialien und Bauteile und erfordern ihre zerstörungsfreie Charakterisierung mit angepasster Ortsauflösung. Dazu sind wegen der passenden Wellenlängen Röntgen-Refraktionsverfahren einsetzbar. Die resultierende Kleinwinkelstreuung verursacht lokal große Intensitäten, die durch Umlagerung oder Fokussierungseffekte das Primärstahlniveau übersteigen können. Mit monochromatischer Synchrotronstrahlung an homogenen Musterproben einfacher Geometrien (Platten und Zylinder) wird die Dominanz der Refraktionsintensität gegenüber der Totalreflexion dargestellt. Der Refraktionseffekt kann für Einstrahlwinkel bis zu einigen Grad genutzt werden; die typischen Streuwinkel liegen in der Größenordnung von Bogensekunden bis -minuten. Darüber hinaus wird die Bestimmung der inneren Oberflächen, Poren und Nanorisse auch orientierungsspezifisch mit Laborausrüstungen demonstriert. T2 - DGZfP-Jahrestagung 2013 CY - Dresden, Germany DA - 06.05.2013 KW - Röntgenrefraktion KW - Kleinwinkelstreuung KW - Refraktionstopographie KW - Nanostrukturen PY - 2013 SN - 978-3-940283-49-8 IS - Mo.2.A.2 SP - 1 EP - 10 AN - OPUS4-28691 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, Bernd R. A1 - Lange, Axel A1 - Harwardt, Marco A1 - Hentschel, Manfred P. A1 - Illerhaus, Bernhard A1 - Goebbels, Jürgen T1 - Synchrotron Refraction CT and Synchrotron Bragg Magnification CT for NDE T2 - International Symposium on Digital industrial Radiology and Computed Tomography (DIR 2007) CY - Lyon, France DA - 2007-06-25 KW - X-ray Refraction KW - Diffraction Enhanced Imaging (DEI) KW - Bragg Magnification KW - Synchrotron Radiation KW - Computed Tomography (CT) KW - Metal Matrix Composites (MMC) KW - Lightweight Materials KW - Aerospace PY - 2007 IS - CD-ROM SP - 1 EP - 8 CY - Lyon, France AN - OPUS4-16366 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Bruno, Giovanni A1 - Onel, Yener A1 - Wolk, Thomas A1 - Staude, Andreas A1 - Ehrig, Karsten A1 - Müller, Bernd R. T1 - Evaluating porosity in cordierite diesel particulate filter materials: advanced X-ray techniques and new statistical analysis methods T2 - ECNDT 2014 - 11th European conference on non-destructive testing CY - Prague, Czech Republic DA - 2014-10-06 KW - Porous ceramics KW - Diesel particulate filters KW - Pore orientation KW - X-ray computed tomography KW - X-ray refraction KW - DIVA algorithm KW - Phase contrast KW - Edge artefact KW - Soft matter radiography KW - Wavelet transform KW - Huygens elementary waves PY - 2014 SN - 978-80-214-5018-9 SP - 1 EP - 8(?) AN - OPUS4-31973 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bruno, Giovanni A1 - Ehrig, Karsten A1 - Haarring, Holger A1 - Harwardt, Michael A1 - Hentschel, Manfred P. A1 - Illerhaus, Bernhard A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Meinel, Dietmar A1 - Müller, Bernd R. A1 - Onel, Yener A1 - Staude, Andreas A1 - Wolk, Thomas T1 - Industrial and synchrotron X-ray CT applications for materials characterisation N2 - The combination of tomographic, microstructural data with other experimental techniques and with modeling is paramount, if we want to extract the maximum amount of information on material and component properties. In particular, quantitative image analysis, statistical approaches, direct discretization of tomographic reconstructions represent concrete possibilities to extend the power of the tomographic 3D representation to insights into the material and component performance. This logic thread holds equally for industrial and academic research, and valorizes expensive experiments such as those carried out at synchrotron sources, which cannot be daily repeated. We shall show a few examples of possible use of X-ray tomographic data for quantitative assessment of damage evolution and microstructural properties, as well as for non-destructive testing. We will also show how X-ray refraction computed tomography (CT) can be highly complementary to classic absorption CT, being sensitive to internal interfaces. T2 - iCT Conference 2014 - Conference on industrial computed tomography CY - Wels, Austria DA - 25.02.2014 KW - X-ray absorption and refraction CT KW - Quantitative image analysis KW - Statistical analysis KW - Complex microstructure PY - 2014 SN - 978-3-8440-2557-6 SP - 15 EP - 31 PB - Shaker CY - Aachen AN - OPUS4-30484 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, Bernd R. A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Kupsch, Andreas T1 - Numerische Korrektur des Hinterleuchtens von Röntgendetektoren N2 - Eine neuartige Korrektur artefaktisch gemessener Intensitäten von Röntgenflachdetektoren wird vorgeschlagen. Die betrachteten Artefakte betreffen eine diffuse Umverteilung der Intensität und führen zu beträchtlichen Verfälschungen der wahren Schwächung und verletzen mithin das Lambert-Beer'sche Gesetz. Sie werden sowohl in Laborexperimenten mit Röntgenröhren (polychromatische Einstrahlung) als auch mit monochromatischer Synchrotronstrahlung bei Einsatz indirekt konvertierender Detektionssysteme (Fluoreszenzschirm, Optik, CCD-Chip) beobachtet. Dieser Effekt wird als Hinterleuchten bezeichnet. In der vorgestellten Studie werden mittels wohldefinierter Randbedingungen Gesetzmäßigkeiten des Hinterleuchtens untersucht: durch Einsatz monochromatischer Strahlung können Aufhärtungseffekte als Ursache ausgeschlossen werden. Das Hinterleuchten ist umso stärker ausgeprägt, je weniger Detektorfläche vom Objekt abdeckt wird und je stärker das Objekt schwächt. Mit Blick auf Tomographien ergibt sich eine Modulation der 'Dichte' als Funktion des Projektionswinkels, deren Amplitude mit dem Objektumfang steigt (Dynamik). Der isotrope und homogene Ansatz zur numerischen Korrektur macht lediglich Gebrauch von Intensitätsmittelwerten und stellt die Gültigkeit des Schwächungsgesetzes in modifizierter Form wieder her. T2 - DACH-Jahrestagung 2012 CY - Graz, Austria DA - 17.09.2012 KW - Röntgendetektor KW - Hinterleuchten PY - 2012 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-277372 SN - 978-3-940283-44-3 IS - DGZfP-BB 136 SP - P 13 / Mo.4.B, 1 EP - 7 AN - OPUS4-27737 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bruno, Giovanni A1 - Hentschel, Manfred P. A1 - Onel, Yener A1 - Lange, Axel A1 - Kupsch, Andreas A1 - Wolk, Thomas A1 - Staude, Andreas A1 - Ehrig, Karsten A1 - Müller, Bernd R. T1 - Bewertung von Porositätsparametern in Cordierit-Diesel-Partikelfilter-Materialien mit fortgeschrittenen Röntgenverfahren und statistischer Analyse N2 - Bikontinuierliche poröse Keramiken für Filteranwendungen weisen eine komplizierte Mikrostruktur auf, in der Poren und Festkörperphase 'vermischt' sind. Mechanische, thermische sowie Filtereigenschaften können nur präzise bestimmt werden, wenn die Morphologie beider Phasen quantitativ angegeben werden kann. Hier werden unter Anwendung von 3D Computertomographie (CT) und verschiedenen Techniken, die auf der Röntgenrefraktion basieren, die Porosität und die Porenorientierung in keramischen Cordierit-Dieselpartikelfiltern bewertet. Dabei werden zur Auswertung der Tomogramme die Fouriertransformierten sowie eine neu entwickelte richtungssensitive Bildanalyse (DIVA, directional interface variance analysis) angewandt. Sowohl die genannten Messtechniken als auch der statistische Ansatz gestatten die Extraktion optional ortsaufgelöster oder gemittelter Werte. Es ergeben sich sehr gute Übereinstimmungen der experimentell ermittelten Porositätswerte mit Ergebnissen aus Quecksilberintrusionsversuchen als auch der ermittelten Porenorientierung im Vergleich zu publizierten Angaben zur kristallographischen Textur. Dies legt den Schluss nahe, dass die Kenntnis der Grenzflächen (zwischen Poren und Materie) genügt, die morphologischen Eigenschaften solcher Materialien hinreichend zu beschreiben. T2 - DGZfP-Jahrestagung 2014 CY - Potsdam, Germany DA - 26.05.2014 KW - Cordierit KW - Poröse Keramik KW - Porenorientierung KW - Röntgenrefraktion KW - Computer-Tomographie KW - 3D-Mikrostruktur PY - 2014 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-312946 SN - 978-3-940283-61-0 VL - 148 SP - 1 EP - 8 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) CY - Berlin AN - OPUS4-31294 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kupsch, Andreas A1 - Hentschel, Manfred P. A1 - Lange, Axel A1 - Bruno, Giovanni A1 - Müller, Bernd R. T1 - Direkte Röntgenrefraktion an Mikrostrukturen N2 - Die durch Brechung an Mikrostrukturen abgelenkte Röntgenstrahlung wird direkt zweidimensional abgebildet. Dazu werden Modellproben einfacher Geometrie (Fasern, Kapillaren, monodisperse Nano- und Mikropartikel) mit einem auf 50 µm kollimierten Synchrotronstrahl (20 keV) gescannt. Die nach den Regeln der geometrischen Optik an prismatischen und linsenartigen Grenzflächen abgelenkte Strahlung wird in etwa 3 Metern Entfernung von einem Flächendetektor mit 7 µm Ortsauflösung zusätzlich zu der ungestörten Resttransmission des Primärstrahls registriert. In der Abfolge der Radiogramme werden die lokalen Orientierungsänderungen der Probekörper-Grenzflächen bei deren Abtastung mit wenigen Mikrometern Schrittweite bildhaft verfolgt. Mit der hier erreichten Winkelauflösung von etwa 3 Bogensekunden (Streuvektor-Inkremente Δk = 10-3nm-1) kann bei 50 µm Ortsauflösung das Materialvolumen bezüglich innerer Grenzflächen mit Nanometer-Separation auch bei hohen Abtastraten unterhalb einer Sekunde pro Bild charakterisiert werden. T2 - DGZfP-Jahrestagung 2014 CY - Potsdam, Germany DA - 26.05.2014 KW - Computertomographie (CT) KW - Rekonstruktionsalgorithmus KW - DIRECTT KW - Missing wedge KW - Statistische Bewertung PY - 2014 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-312931 UR - http://www.ndt.net/article/dgzfp2014/papers/di1b2.pdf SN - 978-3-940283-61-0 IS - DGZfP-BB 148 SP - Di.1.B.2, 1 EP - 9 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) CY - Berlin AN - OPUS4-31293 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Shashev, Yury A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Evsevleev, Sergei A1 - Britzke, Ralf A1 - Bruno, Giovanni A1 - Müller, Bernd R. T1 - Talbot-Lau Röntgen-Interferometrie für die zerstörungsfreie Prüfung N2 - Im vergangenen Jahrzehnt sind gitterinterferometrische Röntgenabbildungen zunehmend in den Fokus des Interesses gerückt. Sie sind insbesondere dann Vorteil, wenn der in der Standardradiographie erreichbare Kontrast nicht genügt, schwach absorbierende Mikro- und Nanostrukturen abzubilden. Auf Kosten mehrerer Aufnahmen gestattet die Talbot-Lau Gitterinterferometrie, die Beiträge aus Absorption, Refraktion und (refraktiver) Streuung zu trennen. Dazu werden die Störungen der Interferenzmuster von Phasengittern ausgewertet. Im Gegensatz zu einer Vielzahl anderer refraktionsbasierter Abbildungsmethoden kann diese Technik mit konventionellen Röntgenröhren (mit divergenter, polychromatischer Strahlung) angewendet werden. Damit ist die Technik geeignet, typische ZfP-Fragestellungen zu lösen. Hier stellen wir Untersuchungen zur Effizienz von Phasengittern vor. Die Visibilität (d.h. die Höhe der Oszillation im Interferenzmuster) wird als Funktion verschiedener geometrischer Parameter verfolgt. Eine Rotation um die Achse parallel zu den Gitterstegen ändert die Form des Gitterprofils (d.h. die Verteilung der Phasenschiebungen). Die kontinuierliche Variation des Winkels und des Detektionsabstandes führt zur Identifikation von ausgezeichneten Kombinationen mit maximaler Visibilität, wobei die Abstände deutlich geringer sind als im Standardaufbau mit senkrechter Gitterbestrahlung. Unsere Studie umfasst Simulationen für monochromatische Quelle und den Vergleich zu experimentellen Ergebnissen mit der Synchrotronstrahlung. In der Literatur wurden die Vorteile der Talbot-Lau Interferometrie für die zerstörungsfreie Prüfung von Faserkompositen und Verbundwerkstoffen demonstriert. Hier werden als Beispiele Messungen an Aluminiumtitanat (Al2TiO5) Pulver gezeigt. T2 - DGZfP 2017 CY - Koblenz, Germany DA - 22.05.2017 KW - Gitterinterferometrische Röntgenabbildung KW - Phasengitter KW - Talbot-Lau Interferometrie KW - Zerstörungsfreie Prüfung PY - 2017 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-404691 SP - 1 EP - 10 PB - DGZfP AN - OPUS4-40469 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Shashev, Yury A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Britzke, Ralf A1 - Bruno, Giovanni A1 - Müller, Bernd R. A1 - Hentschel, M. P. T1 - Talbot- Lau interferometry with a non- binary phase grating for non-destructive testing N2 - Grating interferometric set-ups have been established in the last decade. They are promising candidates to obtain enhanced image contrast from weakly absorbing micro and nano structures. They are based on X-ray refraction and near-field diffraction using the Talbot effect. At the expense of taking multiple images, Talbot-Lau grating interferometry allows separating the absorption, refraction, and scattering contributions by analysing the disturbances of a phase grating interference pattern. Contrary to other refraction enhanced methods, this technique can be applied using conventional X-ray tubes (divergent, polychromatic source). This makes it attractive to solve typical non-destructive testing problems. We investigated the efficiency of phase gratings, i.e. the visibility (the amplitude of oscillations) upon variation of propagation distance and phase grating rotation around an axis parallel to the grid lines. This grating rotation changes the grating shape (i.e. the distributions of phase shifts). This can yield higher visibilities than derived from rectangular shapes. Our study includes experimental results obtained from synchrotron radiation, as well as simulations for monochromatic radiation. The advantages of Talbot-Lau interferometry are demonstrated at the example of glass capillaries. T2 - 19th World Conference on Non-Destructive Testing 2016 CY - Munich, Germany DA - 13.06.2016 KW - Talbot- Lau interferometry KW - Phase grating KW - Non-destructive testing PY - 2016 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-383163 SP - Tu_3_G_2, 1 EP - 9 AN - OPUS4-38316 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kupsch, Andreas A1 - Hentschel, Manfred P. A1 - Lange, Axel A1 - Bruno, Giovanni A1 - Müller, Bernd R. T1 - Direct X-ray refraction of micro structures N2 - For the first time we present direct 2D imaging of refracted X-rays without any discrimination of the Primary radiation. X-refraction works in analogy to visible light optics: X-rays are entirely deflected at interfaces where discontinuities of (electron) density occur. This is demonstrated at the example of inner and outer surfaces of model samples of well-defined geometry (fibres, capillaries, and monodisperse micro particles). The samples are scanned through a 50 μm monochromatic (20 keV) pencil beam. In order to warrant a sufficient angular resolution a 2D detector (pixel size 7 μm) is placed 3 m downstream of the sample. Scanning the sample in micron steps allows for detecting local changes of interface / surface orientation directly in two dimensions. At the actual angular resolution of about 3 seconds of arc (scattering vector increments Δk = 10-3 nm-1) and 50 μm spatial resolution (scanning) the material’s inner surfaces (with nanometer separation) can be characterized even at sampling rates below 1 second per frame. Moreover, our technique is suited to directly determine particle diameters of up to 250 nm by means of diffraction fringes. Some potential applications to technical submicron structures are discussed. T2 - ECNDT 2014 - 11th European conference on non-destructive testing CY - Prague, Czech Republic DA - 06.10.2014 KW - X-ray refraction KW - Phase contrast KW - Edge artefact KW - Soft matter radiography KW - Wavelet transformation KW - Huygens elementary waves PY - 2014 SN - 978-80-214-5018-9 SP - 1 EP - 9 AN - OPUS4-31970 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -