TY - GEN A1 - Ewers, Benjamin A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Müller, Bernd R. A1 - Hoehl, a. A1 - Müller, R. A1 - Ulm, G. T1 - Terahertz spectral computed tomography N2 - The novel technique of spectral THz computed tomography is demonstrated at an example of a small plastic figure. The data are reconstructed by conventional filtered back-projection. The reconstruction are discussed. T2 - IRMMW-THz 2009 - 34th International conference on infrared, millimeter, and terahertz waves CY - Busan, Korea DA - 2009-09-21 KW - THz KW - Computed tomography PY - 2009 SN - 978-1-4244-2120-6 SP - 1 EP - 2(?) AN - OPUS4-20546 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Burkert, Andreas A1 - Heyn, Andreas A1 - Müller, Thoralf T1 - Prüf- und Untersuchungsverfahren - Grundlagen, Zielstellungen, Methoden und Entwicklungen T2 - GfKORR-Jahrestagung 2013 - Untersucht, geprüft und dann... Lässt sich Korrosion vorhersagen? CY - Frankfurt/M., Germany DA - 2013-11-12 KW - Korrosionsversuche KW - Korrosionsprüfung KW - Korrosionsuntersuchung PY - 2013 SN - 978-3-935406-52-9 SP - 10 EP - 16 PB - DECHEMA AN - OPUS4-29604 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Onel, Yener A1 - Wolk, Thomas A1 - Staude, Andreas A1 - Ehrig, Karsten A1 - Müller, Bernd R. A1 - Bruno, Giovanni T1 - Evaluating porosity in cordierite diesel particulate filter materials, part 1 X-ray refraction N2 - Bi-continuous porous ceramics for filtration applications possess a particularly complicated microstructure, with porosity and solid matter being intermingled. Mechanical, thermal, and filtration properties can only be precisely estimated if the morphology of both solid matter and porosity can be quantitatively determined. Using x-ray absorption and refraction, we quantitatively evaluate porosity and pore orientation in cordierite diesel particulate filter ceramics. Porosity values turn out to agree with mercury intrusion measurements, while pore orientation factors agree with published crystallographic texture data. KW - Porous ceramics KW - Pore orientation KW - X-ray refraction KW - Synchrotron KW - Interface PY - 2013 DO - https://doi.org/10.4416/JCST2013-00021 SN - 2190-9385 VL - 4 IS - 4 SP - 169 EP - 176 PB - Göller CY - Baden-Baden AN - OPUS4-29939 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Laquai, René A1 - Schaupp, Thomas A1 - Griesche, Axel A1 - Müller, Bernd R. A1 - Kupsch, Andreas A1 - Hannemann, Andreas A1 - Kannengießer, Thomas A1 - Bruno, Giovanni T1 - Quantitative analysis of hydrogen-assisted microcracking in duplex stainless steel through X-ray refraction 3D imaging N2 - While the problem of the identification of mechanisms of hydrogen assisted damage has and is being thoroughly studied, the quantitative analysis of such damage still lacks suitable tools. In fact, while, for instance, electron microscopy yields excellent characterization, the quantitative analysis of damage requires at the same time large field-of-views and high spatial resolution. Synchrotron X-ray refraction techniques do possess both features. In this work, we show how synchrotron X-ray refraction computed tomography (SXRCT) can quantify damage induced by hydrogen embrittlement in a lean duplex steel, yielding results that overperform even those achievable by synchrotron X-ray absorption computed tomography. As already reported in literature, but this time using a non-destructive technique, we show that the hydrogen charge does not penetrate to the center of tensile specimens. By the comparison between virgin and hydrogen-charged specimens, we deduce that cracks in the specimen bulk are due to the rolling process rather than hydrogen-assisted. We show that (micro)cracks propagate from the surface of tensile specimens to the interior with increasing applied strain, and we deduce that a significant crack propagation can only be observed short before rupture. KW - 2101 duplex stainless steel KW - Hydrogen embrittlement KW - Synchrotron radiation KW - X-ray refraction KW - Computed tomography KW - Microcracking PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-542811 DO - https://doi.org/10.1002/adem.202101287 SN - 1438-1656 SP - 1 EP - 10 PB - Wiley-VCH CY - Weinheim AN - OPUS4-54281 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Onel, Yener A1 - Lange, Axel A1 - Staude, Andreas A1 - Ehrig, Karsten A1 - Kupsch, Andreas A1 - Hentschel, Manfred P. A1 - Wolk, Thomas A1 - Müller, Bernd R. A1 - Bruno, Giovanni T1 - Evaluating porosity in cordierite Diesel particulate filter materials, Part 2 statistical analysis of computed tomography data N2 - Complementary to Part 1 of this work, the bi-continuous microstructure of porous synthetic cordierite ceramics for filtration applications was investigated using 3D x-ray computed tomography at different resolutions. Applying both Fast Fourier Transform and a newly developed image analysis algorithm, we quantitatively evaluated porosity and pore orientation. The statistical approach allows extraction of spatially resolved or average values. Porosity values based on x-ray absorption agree with mercury intrusion measurements, while pore orientation factors agree with x-ray refraction data (Part 1 of this work), and with published crystallographic texture data. KW - Pore orientation KW - Porous ceramics KW - Computed tomography KW - 3D microstructure PY - 2013 DO - https://doi.org/10.4416/JCST2013-00022 SN - 2190-9385 VL - 05 IS - 01 SP - 13 EP - 22 PB - Göller CY - Baden-Baden AN - OPUS4-30379 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bruno, Giovanni A1 - Ehrig, Karsten A1 - Haarring, Holger A1 - Harwardt, Michael A1 - Hentschel, Manfred P. A1 - Illerhaus, Bernhard A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Meinel, Dietmar A1 - Müller, Bernd R. A1 - Onel, Yener A1 - Staude, Andreas A1 - Wolk, Thomas T1 - Industrial and synchrotron X-ray CT applications for materials characterisation N2 - The combination of tomographic, microstructural data with other experimental techniques and with modeling is paramount, if we want to extract the maximum amount of information on material and component properties. In particular, quantitative image analysis, statistical approaches, direct discretization of tomographic reconstructions represent concrete possibilities to extend the power of the tomographic 3D representation to insights into the material and component performance. This logic thread holds equally for industrial and academic research, and valorizes expensive experiments such as those carried out at synchrotron sources, which cannot be daily repeated. We shall show a few examples of possible use of X-ray tomographic data for quantitative assessment of damage evolution and microstructural properties, as well as for non-destructive testing. We will also show how X-ray refraction computed tomography (CT) can be highly complementary to classic absorption CT, being sensitive to internal interfaces. T2 - iCT Conference 2014 - Conference on industrial computed tomography CY - Wels, Austria DA - 25.02.2014 KW - X-ray absorption and refraction CT KW - Quantitative image analysis KW - Statistical analysis KW - Complex microstructure PY - 2014 SN - 978-3-8440-2557-6 SP - 15 EP - 31 PB - Shaker CY - Aachen AN - OPUS4-30484 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bruno, Giovanni A1 - Hentschel, Manfred P. A1 - Onel, Yener A1 - Lange, Axel A1 - Kupsch, Andreas A1 - Wolk, Thomas A1 - Staude, Andreas A1 - Ehrig, Karsten A1 - Müller, Bernd R. T1 - Bewertung von Porositätsparametern in Cordierit-Diesel-Partikelfilter-Materialien mit fortgeschrittenen Röntgenverfahren und statistischer Analyse N2 - Bikontinuierliche poröse Keramiken für Filteranwendungen weisen eine komplizierte Mikrostruktur auf, in der Poren und Festkörperphase 'vermischt' sind. Mechanische, thermische sowie Filtereigenschaften können nur präzise bestimmt werden, wenn die Morphologie beider Phasen quantitativ angegeben werden kann. Hier werden unter Anwendung von 3D Computertomographie (CT) und verschiedenen Techniken, die auf der Röntgenrefraktion basieren, die Porosität und die Porenorientierung in keramischen Cordierit-Dieselpartikelfiltern bewertet. Dabei werden zur Auswertung der Tomogramme die Fouriertransformierten sowie eine neu entwickelte richtungssensitive Bildanalyse (DIVA, directional interface variance analysis) angewandt. Sowohl die genannten Messtechniken als auch der statistische Ansatz gestatten die Extraktion optional ortsaufgelöster oder gemittelter Werte. Es ergeben sich sehr gute Übereinstimmungen der experimentell ermittelten Porositätswerte mit Ergebnissen aus Quecksilberintrusionsversuchen als auch der ermittelten Porenorientierung im Vergleich zu publizierten Angaben zur kristallographischen Textur. Dies legt den Schluss nahe, dass die Kenntnis der Grenzflächen (zwischen Poren und Materie) genügt, die morphologischen Eigenschaften solcher Materialien hinreichend zu beschreiben. T2 - DGZfP-Jahrestagung 2014 CY - Potsdam, Germany DA - 26.05.2014 KW - Cordierit KW - Poröse Keramik KW - Porenorientierung KW - Röntgenrefraktion KW - Computer-Tomographie KW - 3D-Mikrostruktur PY - 2014 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-312946 SN - 978-3-940283-61-0 VL - 148 SP - 1 EP - 8 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) CY - Berlin AN - OPUS4-31294 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Onel, Yener A1 - Wolk, Thomas A1 - Staude, Andreas A1 - Ehrig, Karsten A1 - Müller, Bernd R. A1 - Bruno, Giovanni T1 - Evaluating porosity in cordierite diesel particulate filter materials: advanced X-ray techniques and new statistical analysis methods N2 - Bi-continuous porous ceramics for filtration applications possess a particularly complicated microstructure, whereby porosity and solid matter are intermingled. Mechanical, thermal, and filtration properties can only be precisely estimated if the morphology of both solid matter and porosity can be quantitatively determined. Using 3D computed tomography (CT) at different resolutions, and several X-ray refraction-based techniques, we quantitatively evaluated porosity and pore orientation in cordierite diesel particulate filter ceramics.Moreover, applying both Fast Fourier Transform (FFT) and a newly developed image analysis algorithm (directional interface variance analysis, DIVA), we quantitatively evaluated porosity and pore orientation. Both the experimental techniques and the statistical approach allow extraction of spatially resolved or average values.Porosity values from synchrotron computed tomography used turn out to agree with mercury intrusion measurements, while pore orientation factors agree with published crystallographic texture data. This latter point also implies that the study of the pore/matter interface is sufficient to describe the morphological properties of these materials. KW - Diesel particulate filters KW - DIVA Algorithm KW - Pore Orientation KW - Porous Ceramics KW - X-Ray Computed Tomography KW - X-Ray Refraction PY - 2014 DO - https://doi.org/10.4028/www.scientific.net/AST.91.64 SN - 1662-0356 VL - 91 SP - 64 EP - 69 PB - Techna CY - Faenza AN - OPUS4-32069 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Bruno, Giovanni A1 - Onel, Yener A1 - Wolk, Thomas A1 - Staude, Andreas A1 - Ehrig, Karsten A1 - Müller, Bernd R. T1 - Evaluating porosity in cordierite diesel particulate filter materials: advanced X-ray techniques and new statistical analysis methods T2 - ECNDT 2014 - 11th European conference on non-destructive testing CY - Prague, Czech Republic DA - 2014-10-06 KW - Porous ceramics KW - Diesel particulate filters KW - Pore orientation KW - X-ray computed tomography KW - X-ray refraction KW - DIVA algorithm KW - Phase contrast KW - Edge artefact KW - Soft matter radiography KW - Wavelet transform KW - Huygens elementary waves PY - 2014 SN - 978-80-214-5018-9 SP - 1 EP - 8(?) AN - OPUS4-31973 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Burkert, Andreas A1 - Heyn, Andreas A1 - Ebell, Gino A1 - Lehmann, Jens A1 - Müller, Thoralf A1 - Mietz, Jürgen A1 - Fischer, Joachim T1 - Innovative Methoden in der Korrosionsforschung an der BAM N2 - Im Zusammenhang mit Planungs- und Entwicklungsaufgaben, den Forderungen in Normen und Regelwerken, in betrieblichen Arbeitsanweisungen, den Vorgaben für Zulieferteile oder bei der Auseinandersetzung mit Schadensfällen stellen sich häufig Fragen zum Korrosionsschutz sowie zu entsprechenden Prüf- und Untersuchungsverfahren. Die daraus gewonnenen Ergebnisse sollen z. B. eine Eignung von Werkstoffen oder Schutzsystemen unter spezifischen Einsatzbedingungen, die Dauerhaftigkeit des Schutzes, den Nachweis einer gleichbleibenden Qualität, die Vergleichbarkeit bekannter mit neuen Korrosionsschutzkonzepten oder den Wirkungsnachweis für gezielte Systemeingriffe belegen. Schnell wird deutlich, dass sich aus dem Blickwinkel verschiedener Branchen ganz unterschiedliche Anforderungsprofile ergeben, die ihren Niederschlag dann in unterschiedlichen Strategien der Prüf- und Untersuchungsverfahren finden. PY - 2014 SN - 978-3-00-044008-3 SP - 2-1 EP - 2-26 AN - OPUS4-32753 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Müller, Bernd R. A1 - Cooper, R.C. A1 - Lange, Axel A1 - Kupsch, Andreas A1 - Wheeler, M. A1 - Hentschel, Manfred P. A1 - Staude, Andreas A1 - Pandey, A. A1 - Shyam, A. A1 - Bruno, Giovanni T1 - Stress-induced microcrack density evolution in β-eucryptite ceramics: Experimental observations and possible route to strain hardening N2 - In order to investigate their microcracking behaviour, the microstructures of several β-eucryptite ceramics, obtained from glass precursor and cerammed to yield different grain sizes and microcrack densities, were characterized by laboratory and synchrotron x-ray refraction and tomography. Results were compared with those obtained from scanning electron microscopy (SEM). In SEM images, the characterized materials appeared fully dense but computed tomography showed the presence of pore clusters. Uniaxial tensile testing was performed on specimens while strain maps were recorded and analyzed by Digital Image Correlation (DIC). X-ray refraction techniques were applied on specimens before and after tensile testing to measure the amount of the internal specific surface (i.e., area per unit volume). X-ray refraction revealed that (a) the small grain size (SGS) material contained a large specific surface, originating from the grain boundaries and the interfaces of TiO2 precipitates; (b) the medium (MGS) and large grain size (LGS) materials possessed higher amounts of specific surface compared to SGS material due to microcracks, which decreased after tensile loading; (c) the precursor glass had negligible internal surface. The unexpected decrease in the internal surface of MGS and LGS after tensile testing is explained by the presence of compressive regions in the DIC strain maps and further by theoretical arguments. It is suggested that while some microcracks merge via propagation, more close mechanically, thereby explaining the observed X-ray refraction results. The mechanisms proposed would allow the development of a strain hardening route in ceramics. KW - Beta-eucryptite KW - Microcracked ceramics KW - X-ray refraction KW - Tensile load KW - Strain hardening KW - Synchrotron KW - BAMline KW - Computed Tomography KW - CT PY - 2018 UR - http://www.sciencedirect.com/science/article/pii/S1359645417308881 DO - https://doi.org/10.1016/j.actamat.2017.10.030 SN - 1359-6454 SN - 1873-2453 VL - 144 IS - Supplement C SP - 627 EP - 641 PB - Elsevier B.V. AN - OPUS4-43024 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Müller, Andreas T1 - European Information System on Proficiency Testing Schemes available on Internet PY - 2003 SP - 1(?) EP - 2(?) PB - BAM CY - Berlin AN - OPUS4-923 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, Andreas T1 - Information on Proficiency Testing Schemes (Database EPTIS) T2 - 5th Eurolab Symposium CY - Edinburgh, Scotland, UK DA - 2000-10-04 PY - 2000 SP - 1(?) EP - 9(?) AN - OPUS4-957 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Golze, Manfred A1 - Müller, Andreas A1 - Recknagel, Angelika A1 - Steffen, Bernd A1 - Boley, N. A1 - van der Veen, A. T1 - Interlinkages and recognition of proficiency testing schemes PY - 2000 SN - 0949-1775 SN - 1432-0517 PB - Springer CY - Berlin AN - OPUS4-1063 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, Karsten A1 - Schriever, Sina A1 - Wossidlo, Peter A1 - Hamann, Andreas A1 - Löwe, Peter T1 - Bruchmechanische Untersuchungen von Gusseisen mit Kugelgraphit bei Stoss- und Schlagbiege-Beanspruchung T2 - 33. Tagung des DVM-Arbeitskreises Bruchvorgänge CY - Paderborn, Deutschland DA - 2001-02-20 KW - Ductile cast iron KW - DCI KW - Dynamic fracture toughness PY - 2001 SN - 0943-3473 N1 - Sprachen: Deutsch/Englisch - Languages: German/English IS - 233 SP - 267 EP - 274 PB - DVM CY - Berlin AN - OPUS4-1088 LA - mul AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Mielke, Werner A1 - Hampe, Andreas A1 - Lützow, Wolfgang A1 - Müller, Hansjörg A1 - Pastuska, Gerhard A1 - Rook, A. A1 - Schnabel, E. A1 - Sickfeld, Jürgen A1 - Tobisch, Karl A1 - Trubiroha, Peter T1 - Einsatz von Kunststoffen in Pkw - Literaturstudie PY - 1990 SN - 0937-1214 IS - 2 SP - 9 EP - 257 PB - Bundesanstalt für Straßenwesen CY - Bergisch Gladbach AN - OPUS4-11796 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kupsch, Andreas A1 - Hentschel, Manfred P. A1 - Lange, Axel A1 - Müller, Bernd R. T1 - Röntgen-Interface-Radiographie im Dunkelfeld N2 - Es wird ein Verfahren zur Röntgenabbildung schwach absorbierender Objekte vorgestellt. Als kontrastgebender Effekt wird die Röntgenrefraktion an Ober- und Grenzflächen ausgenutzt. Zur Erzeugung eines sogenannten Dunkelfeldes wird ein schwach gekrümmter Transmissionskristall eingesetzt, der lokal, d.h. in einem kleinen Ausschnitt des Einstrahlquerschnitts, die Bragg-Bedingung erfüllt. Innerhalb dieser Zone erscheinen die durch Refraktion abgelenkten Strahlkomponenten als hell leuchtende Interface-Strukturen. Die Synthese mehrerer Dunkelfeldstreifen ergibt hochaufgelöste 2D Beispiel von biologischen und technischen Mikrostrukturen. T2 - DGZfP-Jahrestagung 2013 CY - Dresden, Germany DA - 06.05.2013 KW - Refraction enhanced imaging (REI) KW - Radiographie KW - Dunkelfeldabbildung KW - Röntgenrefraktion PY - 2013 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-286900 SN - 978-3-940283-49-8 IS - Di.3.C.1 SP - 1 EP - 7 PB - Deutsche Gesellschaft für zerstörungsfreie Prüfung e.V. (DGZfP) AN - OPUS4-28690 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hentschel, Manfred P. A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Müller, Bernd R. T1 - Refraktions-Interface-Radiographie T2 - DGZfP-Jahrestagung 2013 CY - Dresden, Germany DA - 2013-05-06 KW - Röntgenrefraktion KW - Kleinwinkelstreuung KW - Refraktionstopographie KW - Nanostrukturen PY - 2013 SN - 978-3-940283-49-8 IS - Mo.2.A.2 SP - 1 EP - 10 AN - OPUS4-28691 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kupsch, Andreas A1 - Hentschel, Manfred P. A1 - Lange, Axel A1 - Müller, Bernd R. T1 - Einfaches Korrigieren des Hinterleuchtens von Röntgendetektoren N2 - Hinterleuchten stellt eine oft unerkannte Fehlweisung in der radiographischen Abbildung mit Flächendetektoren dar, die durch diffuse Umverteilung der Intensität verursacht wird. Dieser Effekt kann die korrekte Transmissions-Intensität eines Probekörpers gemäß dem Lambert-Beer'schen Gesetz erheblich verfälschen. Hinterleuchten wird sowohl mit Bremsstrahlung von Röntgenröhren als auch mit monochromatischer Synchrotronstrahlung beobachtet. Die fehlerhaft reduzierten Schwächungskoeffizienten von einigen 10 % korrelieren mit der Strahlschwächung und dem direkt bestrahlten Detektorbereich. Für eine einfache numerische Korrektur des Hinterleuchtens werden lediglich integrale Intensitätswerte benötigt. KW - Hinterleuchten KW - Röntgendetektor KW - Fluoreszenzschirm KW - Radiographie PY - 2013 DO - https://doi.org/10.3139/120.110478 SN - 0025-5300 VL - 55 IS - 7-8 SP - 1 EP - 5 PB - Hanser CY - München AN - OPUS4-28692 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Müller, Werner A1 - Tatzky-Gerth, Renate A1 - Wöhlecke, Andreas T1 - Vorläufige Richtlinie für die Zulassung von Bewehrungsgittern aus Kunststoff für Deponieoberflächenabdichtungen PY - 2011 SN - 0340-7551 VL - 41 IS - 4 SP - 411 EP - 444 PB - Wirtschaftsverl. NW CY - Bremerhaven AN - OPUS4-25634 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wöhlecke, Andreas A1 - Müller, Werner ED - Kilchert, M. T1 - Aktueller Stand der Zulassung für Geokunststoffe durch die BAM und derzeitige Arbeitsthemen des Fachbeirats und seiner Arbeitsgruppen N2 - Bereits vor der vergangenen Leipziger Deponiefachtagung waren eine Reihe von Zulassungsrichtlinien für Geokunststoffprodukte verabschiedet worden. Dokumente wurden nun überarbeitet und weitere sind hinzugekommen. Die Zulassungsscheine für bereits bestehende und auch neue Zulassungen werden auf dieser Basis für die Produkte erneuert oder erstellt. T2 - 9. Leipziger Deponiefachtagung CY - Leipzig, Germany DA - 26.02.2013 PY - 2013 SP - 29 EP - 43 AN - OPUS4-27901 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Müller, Bernd R. A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Kupsch, Andreas T1 - A comfortable procedure for correcting X-ray detector backlight N2 - A novel approach is suggested to strongly suppress artifacts in radiography and computed tomography caused by the effect of diffuse background signals 'backlighting' of 2D X-ray detectors. Depending on the detector geometry the mechanism may be different. Either based on the optical scattering of the fluorescent screen materials into the optical detection devices or Compton or X-ray fluorescence scattering by the detector components. Consequently, these erroneous intensity portions result in locally different violations of Lambert Beer's law in single projections (radiographs) as a function of the detector area coverage and the magnitude of the attenuation. The absorption of multiple metal sheets is investigated by monochromatic synchrotron radiation, thus excluding beam hardening. The proposed correction procedure simply requires the individual subtraction of one and the same fraction of the primary and transmitted mean intensity, as a constant (non-local) scattering mechanism is assumed. KW - X-ray detector backlighting KW - Radiography KW - Fluorescent screen KW - Diffuse background KW - Computed tomography PY - 2013 DO - https://doi.org/10.1088/1742-6596/425/19/192015 SN - 1742-6588 SN - 1742-6596 VL - 425 IS - 19 SP - 192015-1 EP - 192015-4 PB - IOP Publ. CY - Bristol, UK AN - OPUS4-28262 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, T. A1 - Heyn, Andreas A1 - Burkert, Annette A1 - Ebell, Gino T1 - Erfassung und Analyse der Startvorgänge lokaler Korrosion mittels kombinierter elektrochemischer und mikroskopischer Methoden N2 - Zur Untersuchung der Initiierungsvorgänge und dem Wachstumsverhalten lokaler Korrosionskeime auf nichtrostenden Stählen wurde eine neue elektrochemisch-mikroskopische Messmethode entwickelt. Bei dieser Messmethode wird durch Einsatz eines Echtfarben- Konfokalmikroskops mit Immersionsobjektiv das empfindliche elektrochemische Rauschmessverfahren um eine bildgebende Messkomponente erweitert. Ziel dieser Untersuchung war es, diskrete Rauschmesssignale visuell detektierbaren Korrosionserscheinungen auf der Stahloberfläche nahezu in Echtzeit zuzuordnen. Auf Grund der notwendigen Anforderungen an einen in situ Messaufbau wurde im Rahmen dieser Untersuchung ein neuartiges selbstklebendes Folienelektrodensystem, bestehend aus Gegen- und Bezugselektrode, entwickelt, das für die in situ Messung zum Einsatz kam. Die in situ Untersuchungen wurden an dem austenitischen Chrom-Nickel-Stahl 1.4301 durchgeführt. Als Ergebnis der Experimente konnten Stromtransienten im nA- bis μA-Bereich messtechnisch erfasst werden und mikroskopisch kleinen Korrosionskeimen, die sowohl stabil wie auch metastabil auf der Stahloberfläche auftraten, diskret und zeitnah zugeordnet werden. Weiterhin konnten mit Hilfe der Konfokaltechnik die Volumina und die Mantelflächen der einzelnen Lochdefekte ermittelt werden, sodass durch Auswertung und Kombination der elektrochemischen und mikroskopischen Messergebnisse erstmalig die Korrosionsstromdichte bestimmt werden konnte, die bei der Initiierung der lokalen Lochkeime aufgetreten ist. Damit konnte die Funktionalität und die hohe Empfindlichkeit des elektrochemisch-mikroskopischen Messverfahrens im Rahmen dieser Untersuchung erfolgreich verifiziert werden. T2 - 14. Sommerkurs Werkstoffe und Fügen am Institut für Werkstoff- und Fügetechnik CY - Magdeburg, Germany DA - 23.09.2011 KW - Lochkorrosion KW - Lochkeimbildung KW - Konfokalmikroskopie KW - In situ KW - Elektrochemie KW - Elektrochemisches Rauschen KW - Folienelektrode PY - 2011 SN - 978-3-940961-56-3 SP - 149 EP - 158 AN - OPUS4-24492 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Reiche, I. A1 - Müller, K. A1 - Staude, Andreas A1 - Goebbels, Jürgen A1 - Riesemeier, Heinrich T1 - Synchrotron radiation and laboratory micro X-ray computed tomography - useful tools for the material identification of prehistoric objects made of ivory, bone or antler N2 - Archaeological bone, ivory and antler, as well as objects manufactured from them, are largely studied to extract as much information as possible from these materials. Among others, one key question in archaeology is the exact identification of the material. Even if the identification of different kinds of osseous material seems to be trivial in many cases, it can be a difficult issue when small, heavily carved and more or less altered ancient objects are concerned. This study was focused on the determination of parameters allowing the distinction of archaeological ivory, bone and antler in order to identify the raw material used for the manufacture of prehistoric objects. The high performance of synchrotron radiation (SR) and laboratory-based micro X-ray computed tomography (microCT), providing highly resolved three-dimensional information on the micromorphology, permitted the establishment of such distinctive features of modern references of ivory, antler, land mammal and whale bones: ivory shows characteristic tubular pores with a diameter of about 1 to 2 µm, bone and antler show typical osteon structures. In our measured references, antler shows on average larger and more elongated shaped pores of the osteons compared to terrestrial mammal bone. This feature however depends very much on the original localization of the studied sample within the antler. Whale bones can be distinguished from the other osseous materials by a cancellous, osteoporotic-like structure with irregularly distributed rounded porosities with diameters reaching up to 500 µm. These characteristics have also been tested on determined Palaeolithic fragments, as diagenetic changes during burial have to be considered and may lead to the modification of the parameters established on the basis of modern bone references. In general, the chemical composition of bone objects can change drastically over time while micromorphological features, as evidenced by microCT, seem to be less susceptible to such alterations. In addition, microCT enables the comparison of inner and possibly less altered parts of the objects, and can be considered as completely non-destructive for small mineralised prehistoric objects. In this study, specific morphological features allowing the distinction of ivory and of whale bone from other bone and antler material were determined, even for altered materials dating back to Palaeolithic periods. Thus, we provide, in addition to archaeozoological, chemical and isotopic markers, a new non-destructive tool to identify some raw materials used for the fabrication of osseous objects ranging from recent to prehistoric periods. PY - 2011 DO - https://doi.org/10.1039/c0ja00246a SN - 0267-9477 SN - 1364-5544 VL - 26 IS - 9 SP - 1802 EP - 1812 PB - Royal Society of Chemistry CY - London AN - OPUS4-24338 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Kupsch, Andreas A1 - Müller, Bernd R. T1 - Correction of diffuse X-ray detector based background N2 - A novel approach to strongly suppress artifacts in radiography and computed tomography caused by the effect of diffuse background Signals (“backlight”) of 2D X-ray detectors is suggested. Depending on the detector geometry the mechanism may be different, either based on the optical scattering of the fluorescent screen materials into optical detection devices or Compton or X-ray fluorescence scattering by the detector components. Consequently, these erroneous intensity portions result in locally different violations of Lambert Beer’s law in single projections (radiographs). When used as input data for computed tomography these violations are directly observed via modulation of the projected mass as a function of the rotation Phase and the sample’s aspect ratio (dynamics). The magnitude of the diffuse Background signal depends on the detector area covered by the projected sample. They are more pronounced the smaller the shaded area and the stronger the total attenuation. Moreover, the local intensity mismatch depends on the attenuation of the sample. We present very basic reference data measured with multiple metal foils at a synchrotron radiation source. Beam hardening artifacts can be excluded due to the monochromatic radiation. The proposed correction procedure assumes a constant (non-local) scattering mechanism. T2 - DIR 2011 - International symposium on digital industrial raidology and computed tomography CY - Berlin, Germany DA - 20.06.2011 KW - Backlight KW - X-ray detector KW - Fluorescence screen KW - Synchrotron radiography KW - Computed tomography PY - 2011 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-243589 SN - 978-3-940283-34-4 IS - DGZfP-BB 128 (Poster 24) SP - 1 EP - 7 PB - Deutsche Gesellscahft für Zerstörungsfreie Prüfung e.V. (DGZfP) AN - OPUS4-24358 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Fontana, Patrick A1 - Lehmann, Christian A1 - Müller, Urs A1 - Kühne, Hans-Carsten A1 - Meng, Birgit A1 - Rogge, Andreas T1 - Wärmebehandlung und Autoklavierung von UHPC - Neue Perspektiven für die Betonfertigteilindustrie T1 - Heat curing and autoclaving of UHPC - New perspectives for the precast concrete industry N2 - Das Gefüge von UHPC ist durch eine dicht gepackte und fehlstellenarme Matrix gekennzeichnet. Eine zusätzliche Optimierung ist durch eine Wärmebehandlung bzw. hydrothermale Nachbehandlung (Autoklavierung) unter einem Wasserdampfsättigungsdruck möglich. Die Wärmebehandlung von Beton ist ein in der Betonfertigteilindustrie geläufiges Verfahren, um die Erstarrungszeit zu verkürzen und höhere Frühfestigkeiten zu erreichen. N2 - The structure of UHPC is characterized by a densely packed matrix with only a small number of voids; it can be enhanced further by heat curing or hydrothermal Treatment (autoclaving) subject to water vapor pressure. Heat curing of concrete is commonly applied in the precast industry in Order to shorten its setting time and achieve higher early strengths. KW - Ultrahochleistungsbeton KW - Stahlfasern KW - Nachbehandlung KW - Mikrostruktur KW - Festigkeit PY - 2011 SN - 0373-4331 SN - 1865-6528 N1 - Sprachen: Deutsch/Englisch - Languages: German/English VL - 77 IS - 10 SP - 46 EP - 47 PB - Bauverl. CY - Gütersloh AN - OPUS4-24838 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lange, Axel A1 - Müller, Bernd R. A1 - Hentschel, Manfred P. A1 - Kupsch, Andreas T1 - Korrektur des Hinterleuchtens an CT-Synchrotrondaten N2 - In den unterschiedlichsten Methoden der Computertomographie tritt häufig ein diffuses Untergrundsignal in den Einzelprojektionen auf: im Falle der Parallelstrahl-CT mit Synchrotronstrahlung handelt es sich um ein Hinterleuchten durch den Fluoreszenzschirm, der vor der CCD-Kamera angeordnet ist. Dieses Hinterleuchten unterscheidet sich von dem bekannten Nachleuchten (Phosphoreszenz) durch zeitliche Konstanz. Hier äußert sich das Hinterleuchten als Modulation der projizierten Masse und somit als Funktion der Phase (Projektionswinkel) und des Aspektverhältnisses des Objektes. Der Einfluss des Hinterleuchtens ist abhängig von der Größe des von der Probe abgeschatteten Detektorbereiches und des Objektumfangs (Dynamik). Dies hat u.a. zur Folge, dass Abweichungen vom Absorptionsgesetz auftreten, die umso stärker ausgeprägt sind, je weniger Detektorfläche das Objekt abdeckt und je stärker das Objekt schwächt. Dabei können Aufhärtungseffekte wegen der monochromatischen Strahlung ausgeschlossen werden. Mit Referenzmessungen und einem isotropen, homogenen Ansatz, der diese Abweichung als Hinterleuchten beschreibt, lassen sich die auftretenden Fehler deutlich verringern. T2 - DGZfP-Jahrestagung 2011 CY - Bremen, Germany DA - 30.05.2011 KW - Hinterleuchten KW - Detektor KW - Fluoreszenzschirm KW - Synchrotron-Radiographie KW - Computer-Tomographie PY - 2011 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-250038 SN - 978-3-940283-33-7 IS - DGZfP-BB 127 (P6) SP - 1 EP - 8 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) AN - OPUS4-25003 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wöhlecke, Andreas A1 - Müller, Werner T1 - Prüfung der Funktion von Dichtungskontrollsystemen für Konvektionssperren in Deponieoberflächenabdichtungen N2 - Mit Dichtungskontrollsystemen (DKS) werden Konvektionssperren in Oberflächenabdichtungssystemen von Deponien kontrolliert. Die Funktionsfähigkeit eines eingebauten DKS muss in jedem Projekt zuvor überprüft werden. Diese projektspezifische Funktionsprüfung des DKS selbst wird am Beispiel der Verwendung mit einer Kunststoffdichtungsbahn (KDB) diskutiert. Der grundsätzliche Aufbau, die zugrunde liegenden Messprinzipien und das Ziel der Prüfung werden vorgestellt. Die Anforderungen an die nach der Deponieverordnung (DepV) zugelassenen Systeme hinsichtlich Betrieb, Leitungsfähigkeit und Konstruktion werden beschrieben. Dabei wird auf die Vorgaben der Richtlinie, die einer Zulassung zugrunde liegt, eingegangen. Das mögliche Vorgehen bei der projektspezifischen Kontrollprüfung im Hinblick auf Aspekte wie Vorgehensweise, Zeitpunkt und Randbedingungen sowie äußere Einflussfaktoren werden diskutiert.-------------------------------------------------------------------------------------------------------------------------------------------------------------- Leak detection systems (LDS) are used to control tight barriers in landfill cover systems. However, the efficiency of the installed LDS itself has to be verified in every landfill construction project. As an example the efficiency test for LDS used in connection with geomembranes is discussed in detail. The basic principles, the measuring techniques and objectives of the efficiency testing are described. The requirements for a certification of LDS under the terms of the new German landfill ordinance with regard to operation, capability and design are listed. The conditions necessary for a certification of LDS are introduced. Possible project related efficiency testing procedures with respect to the scope, time of convenience, general conditions as well as external influencing factors are discussed. KW - Dichtungskontrollsysteme KW - Deponieoberflächenabdichtungen KW - Kunststoffdichtungsbahn KW - Deponieverordnung KW - Funktionsprüfung KW - Leak detection systems KW - Landfill cover systems KW - Geomembranes KW - German landfill ordinance KW - Efficiency testing KW - Deponietechnik - Landfill technology KW - Qualitätssicherung - Quality Assurement KW - Umwelttechnik/Umweltschutz - Environmental Technology/Protection PY - 2012 DO - https://doi.org/10.1002/bate.201200027 SN - 0932-8351 SN - 1437-0999 SN - 0005-6820 SN - 0341-1052 SN - 0932-6359 SN - 0932-8351 VL - 89 IS - 12 SP - 851 EP - 857 PB - Ernst & Sohn CY - Berlin AN - OPUS4-27612 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, Werner A1 - Wöhlecke, Andreas ED - Jost, D. ED - Albers, K. T1 - Langzeitverhalten von Kunststoff-Dränelementen und Bewehrungsgittern und die Anforderungen der Deponieverordnung N2 - Ein Geokunststoffprodukt muss in einer Deponieabdichtung unter allen relevanten Einwirkungen seine Funktion mindestens 100 Jahre lang erfüllen. Diese Annahme ist nicht schon allein dann gerechtfertigt, wenn Alterungsuntersuchungen gezeigt haben, dass der verwendete Werkstoff voraussichtlich so lange halten wird. Darüber hinaus gehende Fragestellungen zur Funktionserfüllung, die im Zulassungsverfahren bearbeitet werden müssen, werden am Beispiel von Kunststoff-Dränelementen und Bewehrungsgittern diskutiert. Es geht dabei um die Auswirkung von äußeren Kräften, die über diesen sehr langen Zeitraum einwirken. Die Grenze für noch zulässige Druck- und Scherkräfte bei einem Kunststoff-Dränelement muss ausgelotet und das zugehörige Wasserableitvermögen bestimmt werden. Mögliche Einschränkung für den Herausziehwiderstand eines Bewehrungsgitters müssen abgeschätzt werden. Damit werden auch die Aufgaben zukünftiger Normungstätigkeit Umrissen. Ergänzend werden einige Erläuterungen zu aktuellen Entwicklungen gegeben: Eine neue Ausgabe der Fremdprüferrichtlinie wurde erarbeitet. Zulassungen für Bewehrungsgitter wurden erteilt. Schließlich wird kurz erklärt, was Befristung einer Zulassung, Erlöschen einer Zulassung und Widerruf einer Zulassung bedeuten. T2 - 29. Fachtagung - Die sichere Deponie - Sicherung von Deponien und Altlasten mit Kunststoffen CY - Würzburg, Germany DA - 31.01.2013 KW - Deponieverordnung KW - Zulassung KW - Kunststoff-Dränelemente KW - Bewehrungsgitter aus Kunststoff PY - 2013 SP - 1 EP - 18 CY - Würzburg AN - OPUS4-27705 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, Bernd R. A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Kupsch, Andreas T1 - Numerische Korrektur des Hinterleuchtens von Röntgendetektoren N2 - Eine neuartige Korrektur artefaktisch gemessener Intensitäten von Röntgenflachdetektoren wird vorgeschlagen. Die betrachteten Artefakte betreffen eine diffuse Umverteilung der Intensität und führen zu beträchtlichen Verfälschungen der wahren Schwächung und verletzen mithin das Lambert-Beer'sche Gesetz. Sie werden sowohl in Laborexperimenten mit Röntgenröhren (polychromatische Einstrahlung) als auch mit monochromatischer Synchrotronstrahlung bei Einsatz indirekt konvertierender Detektionssysteme (Fluoreszenzschirm, Optik, CCD-Chip) beobachtet. Dieser Effekt wird als Hinterleuchten bezeichnet. In der vorgestellten Studie werden mittels wohldefinierter Randbedingungen Gesetzmäßigkeiten des Hinterleuchtens untersucht: durch Einsatz monochromatischer Strahlung können Aufhärtungseffekte als Ursache ausgeschlossen werden. Das Hinterleuchten ist umso stärker ausgeprägt, je weniger Detektorfläche vom Objekt abdeckt wird und je stärker das Objekt schwächt. Mit Blick auf Tomographien ergibt sich eine Modulation der 'Dichte' als Funktion des Projektionswinkels, deren Amplitude mit dem Objektumfang steigt (Dynamik). Der isotrope und homogene Ansatz zur numerischen Korrektur macht lediglich Gebrauch von Intensitätsmittelwerten und stellt die Gültigkeit des Schwächungsgesetzes in modifizierter Form wieder her. T2 - DACH-Jahrestagung 2012 CY - Graz, Austria DA - 2012-09-17 KW - Röntgendetektor KW - Hinterleuchten PY - 2012 SN - 978-3-940283-44-3 IS - DGZfP-BB 136 SP - P 13 / Mo.4.B, 1 EP - 7 AN - OPUS4-27737 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Müller, Werner A1 - Biedermann, K. A1 - Engelmann, B. A1 - Wöhlecke, Andreas T1 - Das Zulassungsverfahren für Geokunststoffe im Deponiebau N2 - Die neue Deponieverordnung regelt im Anhang 1 auch den Einsatz von Geokunststoffen im Deponiebau. Deren Eignung muss der zuständigen Behörde gegenüber nachgewiesen werden. Auf die entsprechenden Regelungen wurde im ersten Teil dieses Aufsatzes eingegangen. Zumindest in den nächsten Jahren kommt nur ein Nachweis durch Vorlage einer Zulassung der BAM Bundesanstalt für Materialforschung und -prüfung in Betracht. Das Zulassungsverfahren wird in der Deponieverordnung geregelt. Die Zulassungsbehörde soll u.a. nicht nur ein bestimmtes Produkt auf der Grundlage von Zulassungsrichtlinien überprüfen, sondern auch in Zusammenarbeit mit einem Fachbeirat Anforderungen an den fachgerechten Einbau und das Qualitätsmanagement festlegen. Das Zulassungsverfahren und einige wesentliche technische Zulassungsanforderung, die für Kunststoffdichtungsbahnen, Schutzschichten, Geotextilien, Kunststoff-Dränelement, Bewehrungsgitter aus Kunststoff und Dichtungskontrollsysteme inzwischen erarbeitet und in Zulassungsrichtlinien beschrieben wurden, werden erläutert. KW - Deponieverordnung KW - Deponieabdichtungssysteme KW - BAM-Zulassung KW - Geokunststoffe PY - 2012 SN - 0027-2957 SN - 1863-9763 VL - 44 IS - 02 SP - 94 EP - 101 PB - Erich Schmidt CY - Berlin AN - OPUS4-25513 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Kupsch, Andreas A1 - Müller, Bernd R. T1 - Numerical correction of X-ray detector backlighting N2 - A novel approach to strongly suppress artifacts in radiography and computed tomography caused by the effect of diffuse background signals ('backlighting') of 2D X-ray detectors is suggested. Depending on the detector geometry the mechanism may be different, either based on the optical scattering by the fluorescent screen materials into optical detection devices or Compton or X-ray fluorescence scattering by the detector components. Consequently, these erroneous intensity portions result in locally different violations of Lambert–Beer's law in single projections (radiographs). When used as input data for computed tomography these violations are directly observed via modulation of the projected mass as a function of the rotation phase and the sample’s aspect ratio (dynamics). The magnitude of the diffuse background signal depends on the detector area covered by the projected sample. They are more pronounced the smaller the shadowed area and the stronger the total attenuation. This implies that the reconstruction suffers from additional anisotropic artifacts caused by elongated sample structures. This issue is studied simply by absorption of flat plates in a conventional laboratory radiography set-up and at a synchrotron radiation facility. In the latter case beam hardening artifacts can be excluded due to the monochromatic radiation. The proposed correction procedure requires simple integral intensity offsets as a constant (non-local) light scattering mechanism is assumed. KW - Detector backlighting KW - X-ray detector scattering KW - Fluorescent screen KW - Diffuse background KW - Computed tomography PY - 2012 DO - https://doi.org/10.3139/146.110659 SN - 1862-5282 VL - 103 IS - 2 SP - 174 EP - 178 PB - Carl Hanser CY - München AN - OPUS4-25553 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wöhlecke, Andreas A1 - Müller, Werner ED - Kilchert, M. T1 - Aktuelle Informationen zum Stand der Arbeit und zu den Arbeitsergebnissen des Fachbeirates der BAM zur Zulassung von Geokunststoffen und Dichtungskontrollsystemen T2 - 8. Leipziger Deponiefachtagung - Planung, Bau, Betrieb, Stolllegung, Nachsorge, Nachnutzung und Rückbau von Deponien CY - Leipzig, Deutschland DA - 2012-02-28 PY - 2012 SP - 37 EP - 49 AN - OPUS4-25556 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wöhlecke, Andreas A1 - Müller, Werner ED - Burkhardt, G. ED - Egloffstein, T. T1 - Neue Richtlinien zur Zulassung von Kunststoffdichtungsbahnen, Kunststoff-Dränelementen und Geokunststoffen für Trenn-, Filter-, Schutz- und Bewehrungsfuntkionen sowie Dichtungskontrollsystemen gemäß neuer DepV T2 - Abschluss und Rekultivierung von Deponien und Altlasten 2010 - Die Umsetzung der neuen Deponieverordnung - praktische Erfahrungen im Vollzug und erste Änderungsverordnung zur neuen DepV CY - Karlsruhe, Deutschland DA - 2010-10-13 PY - 2010 SN - 978-3-939662-08-2 VL - 19 SP - 49 EP - 64 PB - ICP Eigenverlag Bauen und Umwelt CY - Karlsruhe AN - OPUS4-25557 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Vercoutère, C. A1 - Müller, K. A1 - Chiotti, L. A1 - Nespoulet, R. A1 - Staude, Andreas A1 - Riesemeier, Heinrich A1 - Reiche, I. T1 - Rectangular beads from the final gravettian level of the Abri Pataud: raw material identification and its archaeological implications N2 - The Final Gravettian level (level 2) of the abri Pataud (Dordogne, France) yielded a large assemblage of body ornaments that consists essentially of 85 quite standardized rectangular beads. Some uncertainty remained about the raw material in which these small beads were made: mammoth ivory, reindeer antler or bone? Non-invasive methods were employed in order to determine the raw material. First chemical analyses using microbeam Proton Induced X-ray Emission analysis (microPIXE) did not enable us to conclude definitively. Therefore, synchrotron and laboratory X-ray microtomography (microCT) were applied on eight beads and allowed us to identify ivory for all of them except for one, which shows slightly different morphological features. KW - Abri Pataud KW - Gravettien final KW - Ivoire de mammouth KW - MicroPIXE KW - MicroCT KW - Perles rectangulaires KW - Final Gravettian KW - Mammoth ivory KW - Rectangular beads PY - 2011 SN - 1960-1360 VL - 35 SP - 259 EP - 271 PB - Presses Univ. de Rennes CY - Rennes AN - OPUS4-26250 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wöhlecke, Andreas A1 - Müller, Werner T1 - Geosynthetics and their certification for landfill liner and capping systems in Germany T2 - 5th International conference geosynthetics Middle East 2012 CY - Abu Dhabi, UAE DA - 2012-11-19 PY - 2012 IS - Chapter 15 SP - 173 EP - 184 CY - Würzburg AN - OPUS4-27784 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wöhlecke, Andreas A1 - Müller, Werner ED - Egloffstein, T. ED - Burkhardt, G. T1 - Stand der Zulassungen von Geokunststoffen im Bereich Deponien T2 - 22. Karlsruher Deponie- und Altlastenseminar 2012 - Abschluss und Rekultivierung von Deponien und Altlasten CY - Karlsruhe, Germany DA - 2012-10-17 PY - 2012 SN - 978-3-939662-12-9 VL - 23 SP - 59 EP - 75 PB - ICP Eigenverlag Bauen und Umwelt CY - Karlsruhe AN - OPUS4-27785 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hentschel, Manfred P. A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Müller, Bernd R. A1 - Schors, Jörg T1 - Das Anwendungspotential der Röntgen-Topographie vom Mikroriss bis zur Gepäckprüfung T2 - DGZfP-Jahrestagung 2007 CY - Fürth, Deutschland DA - 2007-05-14 KW - CFK KW - Bildgebende Röntgenverfahren KW - Röntgen-Topographie und -Streuung KW - Keramik KW - Explosivstoffe KW - Ermüdungsrisse PY - 2007 SN - 978-3-931381-98-1 SP - 1 EP - 9 PB - DGZfP CY - Berlin AN - OPUS4-15799 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Schors, Jörg A1 - Müller, Bernd R. A1 - Harwardt, Michael T1 - Vom Synchrotron ins Labor - Konversion von Einkristall-Techniken für Röntgenröhren KW - Einkristall KW - Röntgenbeugung KW - Synchrotron KW - Divergenz PY - 2008 SN - 0025-5300 VL - 50 IS - 10 SP - 580 EP - 587 PB - Hanser CY - München AN - OPUS4-18248 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Güttler, B. A1 - Schiel, D. A1 - Danzebrink, H. A1 - Unger, Wolfgang A1 - Gross, Thomas A1 - Lippitz, Andreas A1 - Müller, J.-P. T1 - Physical and Chemical Characterization of Thermal and Native Siliconoxide layers on Silicon T2 - Symposium "Reference Materials for Technologies in the New Millenium" CY - Berlin, BAM, Germany DA - 2000-05-22 PY - 2000 SP - 1(?) EP - 7(?) AN - OPUS4-6924 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Rosemann, P. A1 - Müller, Thoralf A1 - Babutzka, Martin A1 - Heyn, Andreas ED - J. Grosch, ED - E.J. Mittemeijer, T1 - Qualitätsbewertung von Schneidwaren durch Kurzzeit-Korrosionsprüfung N2 - Bei der Qualitätsbewertung von Schneidwaren aus nichtrostenden martensitischen Chrom-Stählen stellt die Überprüfung der Korrosionsbeständigkeit ein wichtiges Kriterium dar. Allgemein üblich sind Wechseltauchversuche mit relativ hohem zeitlichem und auswertungsbedingtem Aufwand, die noch dazu zerstörend sind und teilweise fragwürdige Ergebnisse liefern. In den letzten Jahren wurden neue Ansatze der Prüfung geschaffen, die eine nahezu zerstörungsfreie Kurzzeit-Korrosionsprüfung erlauben. Es wird gezeigt, dass mit dem elektrochemischen Rauschen sehr empfindlich Einflüsse des Härtens und der Oberflächenbehandlung auf die Korrosionsbeständigkeit nachgewiesen werden können, wodurch eine schnelle und objektive Qualitätsbewertung innerhalb des Fertigungsprozesses und der Endkontrolle von Produkten möglich ist. Das für die Prüfmethodik ausgenutzte Phänomen des elektrochemischen Rauschens zielt darauf ab, den Beginn der Korrosion empfindlich und schnell zu detektieren, ohne die Prüfbedingungen maßlos zu verschärfen und Produkte damit zu zerstören. Neben der Funktionalität der Prüfung stehen aber auch die Anwenderfreundlichkeit und somit die Akzeptanz bei den Herstellern im Vordergrund. Aus diesem Grund wurde zusätzlich ein Indikatortest (KorroPad) als praxistaugliche Alternative zum elektrochemischen Rauschen angewendet. Die Ergebnisse zeigen eine gute Übereinstimmung beider Methoden und ermöglichen eine effektive betriebliche Qualitätsüberwachung von Schneidwaren. KW - Schneidwaren KW - Nichtrostender Stahl KW - Korrosion KW - Prüfmethoden KW - Qualitätskontrolle KW - Cutlery KW - Stainless steel KW - Corrosion KW - Testing methods KW - Quality control PY - 2013 DO - https://doi.org/10.3139/105.110195 SN - 1867-2493 VL - 68 IS - 5 SP - 224 EP - 235 PB - Hanser CY - München AN - OPUS4-29341 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, Werner A1 - Jakob, Ines A1 - Robertson, Daniela A1 - Tatzky-Gerth, Renate A1 - Wöhlecke, Andreas T1 - Die oxidative Alterung von Geokunststoffen aus Polyethylen und Polypropylen N2 - Geokunststoffe aus Polyethylen (PE) oder Polypropylen (PP) müssen mit Antioxidantien (AO) stabilisiert werden, damit sie die für die Anwendung in der Geotechnik erforderliche Lebensdauer erreichen. Die Lebensdauer ist dann aber nicht durch die Empfindlichkeit des Polymers gegen Oxidation, sondern durch den Verlust der AO im Laufe der Zeit bedingt. AO können durch den Verbrauch bei Oxidationsreaktionen, durch den Abbau im Polymer, durch die Wanderung an dessen Oberfläche, durch den Abbau auf der Oberfläche, schließlich durch Abdampfen von der Oberfläche oder durch sich Lösen in einem umgebenden flüssigen Medium verloren gehen. Bei den Geokunststoffen aus PP und PE wie auch bei anderen polyolefinen Kunststoffprodukten findet man häufig zwei bestimmte „Pakete“ aus Antioxidantien: (1) eine Kombination von Substanzen aus bestimmten Klassen von sterisch gehinderten Phenolen und Phosphiten und (2) eine Substanz aus der Klasse der sterisch gehinderten Amine (HAS) in Verbindung mit einer geringfügigen phenolischen und phosphitischen Verarbeitungsstabilisierung der Formmasse. Der Verlust der AO wie auch der oxidative Abbau der mechanischen Eigenschaften des Geokunststoffs verläuft ganz unterschiedlich, je nachdem mit welchem Paket stabilisiert wurde. Diese Unterschiede werden im Rahmen eines „3-Stadien-Modells“ diskutiert. Stadium A: die Antioxidantien gehen verloren. Stadium B: die Oxidation läuft langsam an. Stadium C: die Oxidation wirkt sich mehr oder weniger drastisch auf die Produkteigenschaften aus. Dabei zeigt sich, dass das Modell nur auf das Paket 1 anwendbar ist. Im Falle des Pakets 2 findet in gewissem Umfang schon im Stadium A ein oxidativer Abbau statt, ln beiden Fällen ist es aber die AO-Verlustzeit die eigentlich die Lebensdauer bestimmt. Es werden dann Abschätzungen der Lebensdauer von PEHDDichtungsbahnen und von PP-Vliesstoffen gegeben. Die Prüfung und Bewertung der oxidativen Beständigkeit muss die Eigenart der Wirkung und des Verlusts unterschiedlicher Stabilisierungen berücksichtigen. Vor diesem Hintergrund wird die Hochdruck-Autoklav-Prüfung beurteilt. Es werden die Besonderheiten dieser Prüfmethode aufgezeigt, die sich jeweils bei der Anwendung auf Produkte ergeben, die entweder mit dem Paket 1 oder dem Paket 2 stabilisiert wurden. Eine Vorhersage der Lebensdauer unter Anwendungsbedingungen aus den Ergebnissen der Autoklav-Prüfung ist sehr schwierig und vermutlich nur in bestimmten Fällen überhaupt möglich. Ähnliches gilt auch für die vergleichende Bewertung der oxidativen Beständigkeit von Produkten. T2 - Fachtagung Nutzungsdauer von Rohren und Geokunststoffen aus Polyolefinen CY - Würzburg, Germany DA - 14.11.2013 KW - Geokunststoffe KW - PE KW - PP KW - Oxidative Alterung PY - 2013 SP - 1 EP - 48 PB - SKZ - Das Kunststoff-Zentrum CY - Würzburg AN - OPUS4-29606 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, Werner A1 - Wöhlecke, Andreas T1 - Die Zulassung von Geokunststoffen, Polymeren und Dichtungskontrollsystemen nach der neuen Deponieverordnung T2 - 26. Fachtagung - Die sichere Deponie CY - Würzburg DA - 2010-02-18 KW - Geokunststoffe KW - Zulassung KW - Deponieabdichtungen KW - Deponieverordnung PY - 2010 N1 - Geburtsname von Wöhlecke, Andreas: Tuchscherer, A. - Birth name of Wöhlecke, Andreas: Tuchscherer, A. IS - Kap. B SP - 1 EP - 15 CY - Würzburg AN - OPUS4-20923 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hentschel, Manfred P. A1 - Lange, Axel A1 - Kupsch, Andreas A1 - Müller, Bernd R. T1 - Rekonstruktion unvollständiger computertomografischer Modelldatensätze mit Directt-Algorithmus N2 - Modellrechnungen zur Rekonstruktion unvollständiger computertomographischer Datensätze werden zur Ermittlung der Vorteile des neuen Directt-Algorithmus gegenüber der konventionellen gefilterten Rückprojektion durchgeführt, insbesondere auch zur Vermeidung experimentell begründeter Unwägbarkeiten. Ein entsprechender Bedarf entsteht seitens erweiterter Forschungsaktivitäten und industrieller Bedürfnisse, wo die Rekonstruktion limitierter Messdatensätze von Artefakten dominiert wird. Die bekanntesten Einschränkungen betreffen das Limited-View- und Few-Angles-Problem sowie die ROI-Situation, die jeweils unabhängig voneinander untersucht werden, in der Anwendung jedoch zumeist undefiniert vermischt sind, wie etwa in der Elektronen-Tomografie. Die hochauflösende Rekonstruktion von Einzelpixeln wird durch die Wahl eines kleinen Modells von nur 1012 Pixeln visualisiert und ist ohne Filterung möglich. Rekonstruktionen von 90°-Sektoren oder 50 % -ROI-Querschnitten sind fast ohne Auflösungseinschränkungen realisierbar. Die bisher nicht bekannte Möglichkeit, auch außerhalb der ROI präzise zu rekonstruieren, wurde als "Extended ROI"-Methode erfolgreich erprobt. KW - Computed tomography KW - Reconstruction algorithm KW - Filtering KW - Limited view KW - Region of interest PY - 2010 SN - 0025-5300 VL - 52 IS - 10 SP - 668 EP - 675 PB - Hanser CY - München AN - OPUS4-22068 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, Bernd R. A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Kupsch, Andreas ED - Kastner, J. T1 - A comfortable procedure for correcting X-ray detector backlight T2 - Conference on industrial computed tomography CY - Wels, Austria DA - 2012-09-19 KW - X-ray detector backlighting KW - Radiography KW - Fluorescent screen KW - Diffuse background KW - Computed tomography PY - 2012 SN - 978-3-8440-1281-1 SN - 1610-4773 SP - 151 EP - 157 PB - Shaker CY - Aachen AN - OPUS4-26768 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Müller, Werner A1 - Biedermann, K. A1 - Engelmann, B. A1 - Wöhlecke, Andreas T1 - Geokunststoffe in der Deponietechnik im Licht der neuen Deponieverordnung KW - Deponieverordnung KW - Deponieabdichtungssysteme KW - BAM-Zulassung KW - Geokunststoffe PY - 2012 SN - 0027-2957 SN - 1863-9763 VL - 44 IS - 1 SP - 8 EP - 12 PB - Erich Schmidt CY - Berlin AN - OPUS4-25437 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, Werner A1 - Wöhlecke, Andreas ED - Jost, D. ED - Albers, K. T1 - Stand der Zulassungen für Geokunststoffe nach der novellierten Deponieverordnung T2 - 28. Fachtagung - Die sichere Deponie - Sicherung von Deponien und Altlasten mit Kunststoffen CY - Würzburg, Deutschland DA - 2012-02-09 KW - Deponieverordnung KW - BAM-Zulassung KW - Geokunststoffe KW - Kunststoff-Dränelemente KW - Geotextile Filter PY - 2012 IS - Kap. B SP - 1 EP - 22 CY - Würzburg AN - OPUS4-25462 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lange, Axel A1 - Kupsch, Andreas A1 - Hentschel, Manfred P. A1 - Müller, Bernd R. T1 - Straightforward correction of X-ray detector backlighting N2 - A novel approach to strongly suppress artifacts in radiography and computed tomography caused by the effect of diffuse background signals ('backlighting') of 2D X-ray detectors is suggested. Depending on the detector geometry the mechanism may be different, either based on the optical scattering of the fluorescent screen materials into optical detection devices or Compton or X-ray fluorescence scattering by the detector components. Consequently, these erroneous intensity portions result in locally different violations of Lambert Beer’s law in single projections (radiographs) as function of the detector area coverage and the magnitude of the attenuation. The absorption of multiple metal sheets is investigated by monochromatic synchrotron radiation, thus excluding beam hardening. The proposed correction procedure simply requires the individual subtraction of one and the same fraction of the primary and transmitted mean intensity, as a constant (non-local) scattering mechanism is assumed. T2 - 18th WCNDT - World conference on nondestructive testing CY - Durban, South Africa DA - 2012-04-16 KW - X-ray detector backlighting KW - Radiography KW - Fluorescent screen KW - Diffuse background KW - Computed tomography PY - 2012 UR - http://www.ndt.net/article/wcndt2012/papers/205_wcndtfinal00205.pdf SN - 978-0-620-52872-6 SP - 1 EP - 8(?) AN - OPUS4-25835 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lange, Axel A1 - Kupsch, Andreas A1 - Müller, Bernd R. A1 - Hentschel, Manfred P. T1 - Edge artefacts of radiographic images by X-ray refraction N2 - The relevance of nano sized structures and interfaces in upcoming technologies requires new non-destructive Xray techniques exploiting attenuation as well as scattering. In the course of driving the resolution and the contrast of modern radiography into micro and nano metre dimension the inevitable scattering effects require increased attention. Several radiologists interpret the observed edge artefacts simply by 'phase contrast' due to different X-ray path lengths within the sample and others refer to Fresnel scattering. The ultra small angle scattering is of high intensity and may reach the level of the primary beam. We present monochromatic synchrotron measurements on rather simply shaped objects (such as plates and cylinders) which prove clearly the dominance of refraction intensity over total reflection and coherent small angle scattering. The refraction conditions hold for angles of incidence of several degrees to the surface, but typical deflection angles range from several seconds to minutes of arc. Additionally to the concept of 'phase contrast' of the primary beam its deflection becomes the essential issue. The appropriate removal of the attenuation contribution enables the imaging of inner surfaces and interfaces by refraction scanning topography. The presented measurements of reference particles demonstrate the reliability of laboratory refraction scanners applying X-ray tubes. T2 - 18th WCNDT - World conference on nondestructive testing CY - Durban, South Africa DA - 2012-04-16 KW - X-ray refraction KW - Small angle scattering KW - Phase contrast radiography KW - Refraction topography KW - Nanostructures KW - Nanocracks PY - 2012 UR - http://www.ndt.net/article/wcndt2012/papers/274_wcndtfinal00274.pdf SN - 978-0-620-52872-6 SP - 1 EP - 11(?) AN - OPUS4-25836 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wöhlecke, Andreas A1 - Müller, Werner ED - Egloffstein, T. ED - Burkhardt, G. T1 - Zulassung von Bewehrungsgittern aus Kunststoff für den Deponiebau N2 - Geokunststoffe müssen ihre Funktion über einen Zeitraum von mindestens 100 Jahren erfüllen. Bei der Beurteilung müssen alle relevanten und damit zu erwartenden Einwirkungen auf die Produkte berücksichtigt werden. Dies gilt im besonderen Maße für Produkte, die befristetet zugelassen werden. Bei der Beurteilung der Produkte reicht es nicht ausschließlich, den reinen chemischen Abbau des Grundwerkstoffes zu betrachten. Weitergehende Fragestellungen müsse geklärt werden. So müssen z. B. Auswirkungen von mechanischen Belastungen, die über einen sehr langen Zeitraum wirken, betrachtet werden. In diesem Zusammenhang soll das Zulassungskonzept für Bewehrungen aus Kunststoff vorgestellt werden. Hier müssen mögliche Einschränkungen für den Herausziehwiderstand abgeschätzt werden. Ergänzend werden einige Erläuterungen zu aktuellen Entwicklungen der Arbeit der BAM und des Fachbeirats gegeben: Eine neue Ausgabe der Fremdprüferrichtlinie wurde erarbeitet. Befristete Zulassungen für Bewehrungsgitter und neue Zulassungen für Kunststoff-Dränelemente wurden erteilt. In bestimmten Fällen ist es sinnvoll und hilfreich, nur befristete Zulassungen zu erteilen. Daher werden Hintergründe für Befristungen erläutert. Schließlich wird dargelegt, was die Begriffe Befristung einer Zulassung, Erlöschen einer Zulassung und Widerruf einer Zulassung bedeuten. T2 - 23. Karlsruher Deponie- und Altlastenseminar 2013 - Abschluss und Rekultivierung von Deponien und Altlasten 2013 CY - Karlsruhe, Germany DA - 16.10.2013 KW - Deponien KW - Kreislaufwirtschaft KW - Rekultivierung von Altlasten PY - 2013 SN - 978-3-939662-13-6 VL - 24 SP - 59 EP - 70 PB - ICP Eigenverlag Bauen und Umwelt AN - OPUS4-29692 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -