TY - CONF A1 - Auersch, Lutz T1 - Prediction of building noise and vibration – 3D finite element and 1D wave propagation models N2 - Construction work or traffic excite nearby buildings, and the perceptible or audible vibration can be a nuisance for the inhabitants. The transfer of the vibration from the free field to the building has been calculated by the finite element method for many models in consultancy and research work. The analysis for all storeys of certain building points such as walls, columns and floors unveiled some rules, some typical modes, and some wavetype responses. A simplified building-soil model has been created, which includes well these effects of building-soil resonance, wall/column resonance, floor resonances, and the high-frequency reduction. The model consists of one wall for a wall-type apartment building or a column for each specific part (mid, side or corner) of a column-type office building. The building response in the high-frequency (acoustic) region is calculated as mean values over all storeys and over wider frequency bands, by wave-type asymptotes of an infinitely tall building, and by the soil to wall ratio of impedances. The secondary noise is predicted by Transfer values between the building vibration (center of floors, walls at a room corner) and the sound pressure. T2 - Euronoise 2021 CY - Online meeting DA - 25.10.2021 KW - Building vibration KW - Finite element models KW - Soil-wall floor model KW - Apartment building KW - Office tower PY - 2021 AN - OPUS4-53703 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Auersch, Lutz T1 - Dynamic measurements during drop tests on stiff foundations N2 - Measurements at the foundation, the surrounding soil and nearby buildings have been done during several drop tests of different containers on different foundations. The first measurements have been done on a big foundation where it should be guaranteed that the foundation is rigid and the container is tested properly. It was controlled that the foundation does not absorb more than 2 percent of the energy of the container. Most of the drop energy is lost in shock absorbers. Later on, a smaller drop test facility has been built on the ground but inside an existing building. It had to be controlled by prediction and measurements that the drop test will not damage the building. Tests from different heights on soft, medium, and stiff targets have been done to find out rules which allow to identify acceptable and unacceptable drop tests. Later on, the biggest drop test facility has been built for masses up to 200 t. It was necessary for the design of the foundation to estimate the forces which occur during the drop tests. On the other hand, the acceptable tests should be selected and controlled by measurements where the impact duration is important. Different sensors, accelerometers, accelerometers with mechanical filters, geophones (velocity transducers), strain gauges, and pressure cells have been applied for these tasks. The signals have been transformed to displacements which proved to be best suited for the interpretation of the impact mechanism. Modell calculations have been used to check and understand the dynamic measurements. The simplest law is the conservation of the momentum which is a good approximation if the impact is short. If the soil under the foundation has an influence on the deceleration of the container, the maximum foundation velocity is lower than the simple estimation. The amplitudes of the foundation could also be estimated from the ground vibrations and their amplitude-distance law. T2 - 27th international Congress on Sound and Vibration (ICSV27) CY - Online meeting DA - 11.07.2021 KW - Drop test KW - Vibration measurement KW - Container loading KW - Foundation load PY - 2021 AN - OPUS4-53256 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Auersch, Lutz T1 - Vehicle-track-soil interaction for track damage, ground vibration and mitigation N2 - A combined finite element boundary element method has been developed to calculate the dynamic interaction of the railway track and the underlying soil. The track-soil results are coupled with a simple vehicle model to establish the force transfer function of the vehicle-track-soil system. Mitigation measures at the track, namely three different tracks with under-sleeper pads, are analysed. The un-sprung vehicle and heavy track masses on soft track elements yield a lower vehicle-tracksoil resonant frequency and a better reduction of the excitation forces at higher frequencies. If the effectiveness of the mitigation is measured as a vibration ratio between the isolated and an un-isolated reference track, the vehicle-track-soil resonance of the reference track has an important influence on the mitigation effectiveness. Therefore, different un-isolated reference tracks are analysed. It is shown how the frequency and amplitude of the vehicle-track resonance are influenced by the stiffness of the rail pads (strongest), the ballast (medium) and the soil (weakest). The reference track models have been compared with shaker tests on two railway tracks with strong resonances. The damage detection and repair control have become important tasks for ballast and slab tracks. Measurements which compare the damaged and the repaired status of the same track section at different times, or which compare a damaged and an intact track section at the same time, have been successfully performed at some sites in Germany and compared with the theoretical behaviour of intact and damaged tracks. T2 - 3. International Conference onRailway Technology CY - Cagliari, Italy DA - 05.04.2016 KW - mitigation KW - railway track KW - track-soil interaction KW - ground vibration KW - undersleeper PY - 2016 AN - OPUS4-37087 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Auersch, Lutz T1 - Modes and waves of coupled roof or floor structures in historical and modern buildings N2 - Long wooden floor beams above a ball room in an old historical palace have been analysed experimentally. The eleven beams are weakly coupled by three layers of floor boards. It has been investigated if the state (the stiffness) of the wooden beams can be determined by vibration measurements of global or preferably local modes. Hammer, heel-drop and ambient excitations have been used. The vibration modes of the structure show dominating local deformations if an impact excitation is applied. This is understood as the positive superposition of several modes which yield the maximum at the excitation point but a cancellation at more distant points. Natural modes have been estimated from these vibration modes by standard and special methods which were necessary for the high damping of the wooden floor. It has been found that all floor beams contribute to each natural mode even for a weak coupling of the beams. In addition to the modal discussion, the impact tests have also been analysed for the wave propagation and amplitude attenuation with distance. The coupling of floor beams has been studied theoretically by an analytic multiple-beam model where the coupling by translational or rotational springs and by a common support motion has been assumed. T2 - 23. International Congress on Sound and Vibration CY - Athen, Greek DA - 10.07.2016 KW - wave analysis KW - floor vibration KW - modal analysis PY - 2016 AN - OPUS4-37091 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Auersch, Lutz T1 - The dynamic behavior of railway tracks with under sleeper pads, finite-element boundary-element model calculations, laboratory tests and field measurements N2 - Results from the calculation of the tracks have been presented. The compliances for the different under sleeper pads have been intensely discussed by the experts. Laboratory tests and field tests have been shortly presented to demonstrate the comprehensive approach of the BAM. N2 - Es werden die Arbeiten der BAM zu schweren Schwellen und weichen Schwellensohlen vorgestellt. Es wurden Berechnungen zum Schwingungsverhalten und zur Erschütterungsminderung durchgeführt. Laborversuche dienten dazu, die elstischen Eigenschaften der Schwellensohlen und die Dauerhaftigkeit der schweren Schwellen zu ermitteln. In Feldversuchen wurde die Minderungswirkung mit Schwingeranregung und mit Zuganregung ermittelt. T2 - Treffen "Schwellen und Schwellensohlen" CY - Berlin, Germany DA - 25.02.2016 KW - sleeper pads KW - railway track KW - ground vibration KW - mitigation PY - 2016 AN - OPUS4-37103 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Auersch, Lutz T1 - Predicting, measuring and explaining the consequences of high-speed railway traffic in respect to the track, underground and environment N2 - Some results of our measurements of the Intercity experimental are presented together with simulated results and their interpretation. Three frequeny ranges could be measured and calculated: low frequencies which decrease very rapidly with distance (the quasi-static part), high frequencies (mainly due to the sleeper passage), and a mid-frequency which has the weakest attenuation with distance and is therefore dominant at the far field. Mono-frequent excitations get a wide frequency band due to the Doppler effect of the moving high-speed train. T2 - Seminar Fahrzeug-Fahrweg-Dynamik, TU Berlin - TH Warschau - BAM CY - Berlin, Germany DA - 25.02.1988 KW - High-speed trains KW - Doppler effect KW - Frequency-specific attenuation PY - 1986 AN - OPUS4-38080 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Auersch, Lutz T1 - A mid-frequency component of train-induced ground vibration due to scattered axle impulses and the irregularities of the soil and ballast N2 - The passage of the train is dominated by the impulses of the static axle loads. The response of the regular homogeneous and irregular soils has been calculated by the finite-element method in frequency domain. The superposition of the impulse responses yields the quasi-static component of the ground vibration which is restricted to very low frequencies and to the close near-field of the track. In case of an irregular soil or ballast of which the stiffness varies randomly in space, a mid-frequency ground vibration component is generated by the scattering of the axle impulses. Measurements will be shown which prove the existence of the mid-frequency ground vibration component and the unique explanation by the scattered axle impulses: many international measurements with a raised mid-frequency component, axle-box measurements with a too low mid-frequency dynamic load, amplitude-speed dependencies which are incompatible with irregularity-induced dynamic loads, and ground vibration reductions due to stiff track elements. T2 - International Conference on Noise and Vibration Engineering (ISMA/USD 2020) CY - Online meeting DA - 07.09.2020 KW - Ground vibration KW - Railway KW - Irregular soil KW - Irregular ballast KW - Axle impulses PY - 2020 AN - OPUS4-51212 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Said, Samir A1 - Auersch, Lutz T1 - Measurement of slab track behaviour at different sites N2 - Measured train passages and hammer impacts in combination with track-soil calculation have been successfully used for the detection of damaged slab tracks. This approach is now extended to intact slab and ballast tracks. The vibrations of many tracks have been measured at several levels from rail, sleeper, track plate, base plate, base layer to the subsoil by velocity or acceleration sensors. The time histories have to be integrated once or twice to get the displacements. The displacement signals include an arbitrary time-dependent shift which must be eliminated or respected in the interpretation. On the other hand, the calculation of slab and ballast tracks have been done in frequency-wavenumber domain. The displacements along the track and the frequency-dependent compliance transfer functions can be calculated. The latter can be compared with the results of the hammer impacts on the track. The deformation of the track can be transformed to time histories for a whole train and compared to the measured train passages. Many slab (and ballast) tracks have been measured at different sites. The displacements of the tracks are presented, and the following parameters have been analysed in the measurement results: slab track vs. ballast track, different types of slab tracks, damaged slab tracks, different trains, switches at different measuring points, an elastic layer, the mortar layer, different soils at different places. The soil should have the dominant influence on the track-plate displacements. Slab and ballast track yield also big differences in maximum displacement and width of deformation. Some of the preceding aspects will be analysed in comparison of measurement and theory. T2 - 26th International Congress on Sound and Vibration (ICSV26) CY - Montreal, Canada DA - 07.07.2019 KW - Displacements KW - Train passage KW - Slab track KW - Hammer impact KW - Vibration measurements PY - 2019 AN - OPUS4-48495 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Auersch, Lutz T1 - Predicted and measured amplitude-speed relations of railway ground vibrations at four German sites with different test trains N2 - The present contribution evaluates four measuring series made by the Federal Institute of Material Research and Testing for the relations between train speed and ground vibration amplitudes. This experimental evaluation is supported by the simulation of the train passages at the different sites by using appropriate excitation mechanisms and forces as well as layered soil models which have been derived from impact measurements at each site. T2 - 13th International Workshop on Railway Noise and Vibration CY - Leuven, Belgium DA - 16.09.2019 KW - Excitation forces KW - Train speed KW - Ground vibration KW - Layered soils PY - 2019 AN - OPUS4-49444 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Auersch, Lutz T1 - Four typical errors in train induced ground vibration and ground vibration mitigation N2 - Mitigation measures of railway induced vibration have been demonstrated at the emission, transmission and immission part. It must be carefully observed that the correct masses and stiffnesses are used. Typical mistakes have been shown, - 1D models for vehicle-track interaction, - impedance instead of stiffness for the infill material of a trench, - rigid buildings or neglecting the soil-building interaction. The dominant mid-frequency part of the ground vibration is due to the irregular soil. T2 - ISO/TC 108/SC 2/WG 8 Working group Ground-borne noise and vibration from rail systems CY - Milano, Italy DA - 14.10.2019 KW - Ground vibration KW - Train excitation KW - Mitigation PY - 2019 AN - OPUS4-49446 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -