TY - CONF A1 - Lohse, Volkmar T1 - Auswahl, Einsatz und Betrieb von Gaswarnanlagen unter Berücksichtigung der DIN EN 60079-29-2 und des ergänzenden Merkblatts T 023 der BG-Chemie T2 - Seminar für Honeywell Analytics CY - Bad Hersfeld, Germany DA - 2009-11-27 PY - 2009 AN - OPUS4-20370 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Negendank, Detlef A1 - Lohse, Volkmar T1 - Gaswarnsysteme in der Sicherheitstechnik - Anforderungen an Messfunktion und funktionale Sicherheit T2 - 12. BAM/PTB-Kolloquium zu Fragen der chemischen und physikalischen Sicherheitstechnik, BAM CY - Berlin, Germany DA - 2010-06-15 PY - 2010 AN - OPUS4-21006 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Rauchegger, Christian A1 - Schmidt, Dirk A1 - Lohse, Volkmar A1 - Negendank, Detlef A1 - Thévenin, D. T1 - Experimentelle Untersuchungen zur Schwergasausbreitung T2 - 10. Fachtagung Anlagen-, Arbeits- und Umweltsicherheit CY - Köthen, Deutschland DA - 2010-11-04 KW - Schwergas KW - Sensortechnik KW - Experimentelle Daten PY - 2010 SN - 978-3-89746-119-2 IS - Paper M-02 SP - 1 EP - 10 CY - Frankfurt/M. AN - OPUS4-22350 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lohse, Volkmar T1 - SIL-Anforderungen an Gaswarnsysteme T2 - Vortrag und Seminar der Firma MSA CY - Berlin, Germany DA - 2010-11-10 PY - 2010 AN - OPUS4-22375 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lohse, Volkmar T1 - Betreiben von Gaswarnanlagen - Merkblätter T 021 und T 023 der BG RCI (BG-Chemie) sowie TRBS 1201 Teil 3 T2 - Vortrag und Seminar der Firma MSA CY - Berlin, Germany DA - 2010-11-10 PY - 2010 AN - OPUS4-22341 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Lohse, Volkmar A1 - Negendank, Detlef A1 - Thedens, M. T1 - Gaswarnsysteme für den Explosionsschutz - Anforderungen an Explosionsschutz, Messfunktion und funktionale Sicherheit N2 - Gaswarnsysteme, aber auch einfachere Gaswarngeräte und -anlagen, finden in der Industrie breite Anwendung zur Gefahrenabwehr in explosionsgefährdeten Bereichen im Sinne der Richtlinie 94/9/EG (ATEX 95). Hierfür werden meist Geräte zur Konzentrationsmessung von brennbaren Gasen mit einem Messbereich von 0 % bis 100 % der jeweiligen UEG eingesetzt. Ziel ist die rechtzeitige und zuverlässige Warnung vor unzulässig hohen Brenngaskonzentrationen unter Betriebsbedingungen. Sauerstoffmessgeräte, die bestimmungsgemäß für die Überwachung von Inertisierungsmaßnahmen verwendet werden, unterliegen ebenfalls den besonderen Anforderungen der ATEX-Richtlinie. KW - Gaswarnsysteme KW - Explosionsschutz KW - Messfunktion KW - Funktionale Sicherheit KW - ATEX PY - 2011 SN - 0030-834X VL - 121 IS - 1 SP - 30 EP - 33 PB - Wirtschaftsverl. NW CY - Bremerhaven AN - OPUS4-23716 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Nooke, Alida A1 - Beck, Uwe A1 - Hertwig, Andreas A1 - Krause, Andreas A1 - Krüger, Hannes A1 - Lohse, Volkmar A1 - Negendank, Detlef A1 - Steinbach, J. T1 - Ellipsometric detection of gases with the surface plasmon resonance effect on gold top-coated with sensitive layers N2 - An ellipsometric gas sensor based on the surface Plasmon resonance (SPR) effect of ~ 43 nm thick gold layers was investigated. To protect the gold layer from contamination and to improve the detection limits, the gold layers were top-coated with 5–6 nm thick layers of organic a-C:H or with inorganic metal oxides TiO2 or ZrO2. The additional layers increased the long-term stability, whereas the metal oxide layers protect better than a-C:H. Furthermore, the additional layers decreased the detection limits by one order of magnitude in case of a-C:H and two orders of magnitude in case of the oxides. It could be shown that the detection limits also depend on the kind of preparation (sol–gel process or physical vapour deposition) of the additional layers. KW - Gas sensor KW - SPR KW - Ellipsometry KW - Sensitive layer KW - TiO2 KW - ZrO2 KW - a-C:H PY - 2011 DO - https://doi.org/10.1016/j.tsf.2010.11.091 SN - 0040-6090 VL - 519 IS - 9 SP - 2659 EP - 2663 PB - Elsevier B.V. CY - Amsterdam AN - OPUS4-23353 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lohse, Volkmar T1 - Auswahl und Einsatz von Gaswarnsystemen zur Abwehr von Gasgefahren T2 - Seminar MSA Auer GmbH CY - Berlin, Germany DA - 2008-11-18 PY - 2008 AN - OPUS4-18085 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lohse, Volkmar T1 - Baumusterprüfung und Zertifizierung der Messfunktion von Gasanalysatoren/Gaswarngeräten T2 - 5. Workshop zur Gassensorik - Multigassensoren und Life Sciences CY - Berlin, Germany DA - 2008-12-04 PY - 2008 AN - OPUS4-18497 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lohse, Volkmar T1 - Gesetzliche und berufsgenossenschaftliche Regelungen in der Gaswarntechnik T2 - Vortrag und Seminar für Honeywell Analytics CY - Berlin, Germany DA - 2010-02-16 PY - 2010 AN - OPUS4-20844 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lohse, Volkmar T1 - Konformitäts-Bewertungsverfahren nach Richtline 94/9/EG für Gaswarngeräte zum Einsatz in explosionsgefährdeten Bereichen T2 - Behörden-Erfahrungsaustauch "Gefahrgutsicherheit, Störfall-Verordnung und Explosionsschutz", Labor-Experementalvortrag, BAM CY - Berlin, Germany DA - 2002-09-10 PY - 2002 AN - OPUS4-3035 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lohse, Volkmar T1 - Explosionsschutz mit Gaswarngeräten T2 - Posteraustellung Sensorik, BAM CY - Berlin, Germany DA - 2002-10-01 PY - 2002 AN - OPUS4-3036 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -