TY - CONF A1 - Müller, Bernd R. A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Kupsch, Andreas ED - Kastner, J. T1 - A comfortable procedure for correcting X-ray detector backlight T2 - Conference on industrial computed tomography CY - Wels, Austria DA - 2012-09-19 KW - X-ray detector backlighting KW - Radiography KW - Fluorescent screen KW - Diffuse background KW - Computed tomography PY - 2012 SN - 978-3-8440-1281-1 SN - 1610-4773 SP - 151 EP - 157 PB - Shaker CY - Aachen AN - OPUS4-26768 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Lange, Axel A1 - Kupsch, Andreas A1 - Hentschel, Manfred P. A1 - Müller, Bernd R. T1 - DIRECTT-Rekonstruktionen im Vergleich zur gefilterten Rückprojektion N2 - Anhand von computertomografischen Messungen und Modellrechnungen werden DIRECTT-Rekonstruktionen im Vergleich mit gefilterten Rückprojektionen bewertet. Dazu wird die Rekonstruktionsqualität mittels einer zirkular erweiterten Modulations-Transfer-Funktion (MTF) und mit integralen Kenngrößen im Radon- und im Ortsraum verglichen. Zur Überprüfung der Rekonstruktionsgenauigkeit experimenteller Daten werden Mustermessungen einfacher Probengeometrien unter definierten physikalischen Bedingungen durchgeführt. Diese beinhalten die Monochromasie, die Unterdrückung von Kantenartefakten und die radiometrische Intensitätsbestimmung. Für die Qualität der Rekonstruktionen mittels DIRECTT erweisen sich sowohl unterschiedliche Rekonstruktionsfilter als auch der Verzicht auf jede Filterung als unerheblich, im Gegensatz zur gefilterten Rückprojektion. KW - Computertomografie KW - Gefilterte Rückprojektion KW - Rekonstruktionsalgorithmen KW - Iterative Rekonstruktion KW - DIRECTT KW - Konvergenz KW - Modulations-Transfer-Funktion (MTF) PY - 2014 UR - http://www.hanser-elibrary.com/doi/pdf/10.3139/120.110610 SN - 0025-5300 VL - 56 IS - 9 SP - 709 EP - 715 PB - Hanser CY - München AN - OPUS4-31378 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Schors, Jörg A1 - Müller, Bernd R. A1 - Harwardt, Michael T1 - Vom Synchrotron ins Labor - Konversion von Einkristall-Techniken für Röntgenröhren KW - Einkristall KW - Röntgenbeugung KW - Synchrotron KW - Divergenz PY - 2008 SN - 0025-5300 VL - 50 IS - 10 SP - 580 EP - 587 PB - Hanser CY - München AN - OPUS4-18248 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Kupsch, Andreas T1 - True 3D-CT-reconstruction in comparison to the FDK-algorithm T2 - 17th World Conference on Non-Destructive Testing CY - Shanghai, China DA - 2008-10-25 KW - Computed tomography KW - Spatial resolution KW - Reconstruction algorithm PY - 2008 SP - 1 EP - 5 PB - International Committee for Non-Destructive Testing CY - Shanghai AN - OPUS4-18568 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hentschel, Manfred P. A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Müller, Bernd R. T1 - Refraktions-Interface-Radiographie N2 - Nanoskalige Strukturen und Grenzflächen bestimmen zunehmend die Funktionalität moderner Materialien und Bauteile und erfordern ihre zerstörungsfreie Charakterisierung mit angepasster Ortsauflösung. Dazu sind wegen der passenden Wellenlängen Röntgen-Refraktionsverfahren einsetzbar. Die resultierende Kleinwinkelstreuung verursacht lokal große Intensitäten, die durch Umlagerung oder Fokussierungseffekte das Primärstahlniveau übersteigen können. Mit monochromatischer Synchrotronstrahlung an homogenen Musterproben einfacher Geometrien (Platten und Zylinder) wird die Dominanz der Refraktionsintensität gegenüber der Totalreflexion dargestellt. Der Refraktionseffekt kann für Einstrahlwinkel bis zu einigen Grad genutzt werden; die typischen Streuwinkel liegen in der Größenordnung von Bogensekunden bis -minuten. Darüber hinaus wird die Bestimmung der inneren Oberflächen, Poren und Nanorisse auch orientierungsspezifisch mit Laborausrüstungen demonstriert. T2 - DGZfP-Jahrestagung 2013 CY - Dresden, Germany DA - 06.05.2013 KW - Röntgenrefraktion KW - Kleinwinkelstreuung KW - Refraktionstopographie KW - Nanostrukturen PY - 2013 SN - 978-3-940283-49-8 IS - Mo.2.A.2 SP - 1 EP - 10 AN - OPUS4-28691 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Manke, I. A1 - Kardjilov, N. A1 - Arlt, Tobias A1 - Grothausmann, R. T1 - Rekonstruktion limitierter CT-Messdatensätze von Brennstoffzellen mit Directt N2 - Die Aufklärung spezifischer Fragestellungen zur Funktionalität von PEM(polymer electrolyte membrane)- und DMFC(Direct Methanol)-Brennstoffzellen bedarf der 3D-Abbildung der spezifischen Komponenten mit unterschiedlichen Strahlungsarten: des Wassergehalts in den Flow Fields mit Neutronen, der Katalysator-Alterung in der MEA (membrane electrode assembly) mit Synchrotronstrahlung und der freien (reaktiven) Katalysator-Oberfläche von Nano-Partikeln mit TEM-Elektronen-Tomografie. Diese Messungen im Bereich der mm- bis nm-Skala unterliegen dabei erheblichen Restriktionen: einer ortsabhängigen Verschmierung der Neutronenradiogramme, Manipulatorinstabilitäten der Synchrotronmessungen sowie einer Kombination von Limited-View-Datensätzen, wenigen Projektionswinkeln und teilweiser Nichtdurchstrahlbarkeit in der Elektronen-CT. Die Vorteile eines fortentwickelten Directt-Algorithmus für die Bewältigung dieser Randbedingungen gegenüber gefilterten Rückprojektionen werden aufgezeigt. KW - Computed tomography KW - Reconstruction algorithm KW - Electron tomography KW - Neutron tomography KW - Catalyst KW - Fuel cell PY - 2010 SN - 0025-5300 VL - 52 IS - 10 SP - 676 EP - 683 PB - Hanser CY - München AN - OPUS4-22070 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kupsch, Andreas T1 - Modeling and removal of edge artiffacts in radiography T2 - Institut für Energie- und Klimaforschung (IEK-3), FZJ CY - Jülich, Germany DA - 2012-10-30 PY - 2012 AN - OPUS4-26868 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Ewert, Uwe A1 - Osterloh, Kurt A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Beckmann, Jörg A1 - Hentschel, Manfred P. ED - Beyerer, J. T1 - Advanced radiological technologies for imaging and characterisation of threats T2 - 2nd Security Research Conference "Future Security" CY - Karlsruhe, Germany DA - 2007-09-12 KW - Threat Detection KW - Dual Energy KW - Multiple View Inspection KW - Terahertz Imaging KW - Explosives PY - 2007 SN - 978-3-86644-147-7 SP - 116 EP - 119 PB - Universitätsverl. CY - Karlsruhe AN - OPUS4-18348 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Müller, Bernd R. A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Kupsch, Andreas T1 - A comfortable procedure for correcting X-ray detector backlight N2 - A novel approach is suggested to strongly suppress artifacts in radiography and computed tomography caused by the effect of diffuse background signals 'backlighting' of 2D X-ray detectors. Depending on the detector geometry the mechanism may be different. Either based on the optical scattering of the fluorescent screen materials into the optical detection devices or Compton or X-ray fluorescence scattering by the detector components. Consequently, these erroneous intensity portions result in locally different violations of Lambert Beer's law in single projections (radiographs) as a function of the detector area coverage and the magnitude of the attenuation. The absorption of multiple metal sheets is investigated by monochromatic synchrotron radiation, thus excluding beam hardening. The proposed correction procedure simply requires the individual subtraction of one and the same fraction of the primary and transmitted mean intensity, as a constant (non-local) scattering mechanism is assumed. KW - X-ray detector backlighting KW - Radiography KW - Fluorescent screen KW - Diffuse background KW - Computed tomography PY - 2013 DO - https://doi.org/10.1088/1742-6596/425/19/192015 SN - 1742-6588 SN - 1742-6596 VL - 425 IS - 19 SP - 192015-1 EP - 192015-4 PB - IOP Publ. CY - Bristol, UK AN - OPUS4-28262 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, Bernd R. A1 - Soares, A.P. A1 - Kupsch, Andreas A1 - Baum, D. A1 - Hesse, B. A1 - Zaslansky, P. T1 - Untersuchung der Integrität von glasfaserverstärkten Zahnstiften mittels Synchrotron-Röntgenrefraktion N2 - Die Integrität der Verstärkungsfasern in Komposit-Zahnstiften ist entscheidend für die Biegefestigkeit und die langfristige Haftung am Zement in den Wurzelkanälen. Es wurde vermutet, dass die Integrität von glasfaserverstärkten Zahnstiften durch das Beschleifen während der zahnmedizinischen Behandlung beeinträchtigt wird. Eine Beschädigung der Fasern führt zu einer erheblichen strukturellen Schwächung über den gesamten Stiftdurchmesser. Glasfragmente, die durch den Kontakt mit dem Zahnbohrer entstehen, können sich vom Stift lösen und die Haftfähigkeit erheblich verringern. Mit Hilfe hochauflösender Synchrotron-Röntgen-Refraktions-Radiographie (SXRR) konnte das Ausmaß der Schäden zuverlässig identifiziert und charakterisiert werden. Dazu wurden die Glasfaserstifte sowohl im Herstellungszustand als auch nach der Bearbeitung mit einem Diamantbohrer untersucht. Die Datensätze wurden zur Visualisierung und Quantifizierung der morphologischen Charakteristika intakter und durch das Beschleifen beschädigter Regionen analysiert. Sie zeigen Schäden im bearbeiteten Bereich (z. B. Brüche, Splitter und Risse) sowie herstellungsbedingte Inhomogenitäten der Fasern mit einer signifikanten Zunahme der inneren Oberflächen in Probenregionen, die durch das Beschleifen beschädigt wurden. T2 - DGZfP Jahrestagung 2022 CY - Kassel, Germany DA - 23.05.2022 KW - Röntgen-Refraktion KW - Verbundwerkstoffe KW - Zahnstifte PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-549231 SP - 1 EP - 7 AN - OPUS4-54923 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Trappe, Volker A1 - Nielow, D. A1 - Hickmann, Stefan A1 - Kupsch, Andreas A1 - Gaal, Mate A1 - Redmer, Bernhard A1 - Krankenhagen, Rainer T1 - Sandwich-Schalenstrukturen in situ charakterisiert mit Thermographie und Felddehnungsmessungen N2 - An der BAM wurde ein Schalenprüfstand entwickelt, mit dem typische Sandwichschalenstrukturen unter simulierter Betriebsbeanspruchung belastet werden können. Im mechanischen Ermüdungsversuch wurden in situ die Entstehung von Schäden in Schalenprüfkörpern mit Test-Imperfektionen mittels der passiven Thermographie und Felddehnungsmessungen verfolgt. Damit konnten der Zeitpunkt, der Schadensursprung und der Schadensfortschritt zerstörungsfrei bestimmt werden. Zudem wurden vergleichend Schalenprüfkörper mit Luftultraschall und der Röntgen-Laminographie untersucht. Im Rahmen eines BMWi-Forschungsvorhabens wurden die Schädigungsmechanismen evaluiert und Empfehlungen für die Praxis der Fertigung von Rotorblättern abgeleitet. In diesem Beitrag wird sich auf die Darstellung der ZfP-Verfahren und der ZfP-Ergebnisse konzentriert. T2 - DGZfP-Jahrestagung 2018 CY - Leipzig, Germany DA - 07.05.2018 KW - Windkraft KW - Rotorblatt KW - Schalenprüfstand KW - Thermographie KW - Laminographie KW - Luftultraschall PY - 2018 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-469395 VL - 166 SP - 1 EP - 11 AN - OPUS4-46939 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kupsch, Andreas T1 - Improved Computed Tomography by the Novel Iterative Algorithm DIRECTT Applied to Various Challenging Experiments T2 - 216th Electro Chemical Society Meeting CY - Vienna, Austria DA - 2009-10-09 PY - 2009 AN - OPUS4-20149 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Hentschel, Manfred P. T1 - Computertomographische 2D-Rekonstruktionen ohne gefilterte Rückprojektion mit DIRECTT T2 - DACH-Jahrestagung 2008 CY - St. Gallen, Schweiz DA - 2008-04-28 KW - Computer-Tomographie KW - Rekonstruktionsalgorithmen KW - Ortsauflösung PY - 2008 SN - 978-3-940283-09-2 IS - DGZfP-BB 113 (Poster 10) SP - 1 EP - 6 AN - OPUS4-17937 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ewers, Benjamin A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Hentschel, Manfred P. T1 - Terahertz spectral imaging techniques in NDT: Topography and computed tomography N2 - The emerging technology of generation and detection of Terahertz waves (1 THz = 1012 Hz) offers diverse potentials in non-destructive testing (NDT) regarding security as well as safety aspects. Herein, we focus on the latter with emphasis on imaging techniques. The THz range (0.1 … 10 THz, 3mm …30 µm) closes the technological gap between ultra high frequency electronics and FIR optics in the electro-magnetic (EM) spectrum. Electro-optical sampling provides straight access to the EM wave including its phase (rather than intensity). THz waves are well suited to characterize non-metallic materials since they penetrate paper, plastics, ceramics and certain composites (e.g. GFC). We employ a commercial fibre-coupled THz time domain spectrometer (TDS) for scanning the samples laterally through a focal spot. At each position the entire temporal pulse train is recorded, which offers the opportunity to use various parameters derivable for imaging. Topographic measurements are performed as reflection set-up. The achievable spatial resolution is diffraction limited at about 100 µm -300 µm (which allows for perception of single defects on a sub-mm scale). In contrast to typical pulse echoed ultrasound testing THz topography is a non-contact inspection tool without coupling agents. Several reflections of subsequent concealed layers are detected instead of just the first encountered one. Comparing to X-ray (radiology) the non-ionizing THz-waves generate images of similar contrast regarding metal and plastic (organic) components, while conventional radiography emphasizes one type of material depending on the energy preselected. Moreover, the full temporal information is exploited to derive spectra in certain selected time windows, i.e. separated spectral properties of each layer in multilayered structures. Tomographic measurements are performed in transmission mode. The sample is mounted on a rotation stage in order to allow for lateral scanning under the different projection angles. The reconstruction is typically performed by filtered backprojection, which is widely used for X-ray CT. The adaption of this technique to the THz range comes along with several experimental drawbacks such as considerable refraction and scattering. According to these difficulties we investigate the occurring artefacts. The THz-TDS provides the opportunity to calculate a separate backprojection of each frequency interval as obtained by the Fourier transformation of the recorded time resolved amplitude. This results in a spectrally resolved reconstruction of each voxel, which is unique in computed tomography technology. T2 - 10th European conference on non-destructive testing CY - Moscow, Russia DA - 2010-06-07 KW - Terahertz time domain spectroscopy KW - Spectral computed tomography KW - 3D topography PY - 2010 UR - http://www.ndt.net/article/ecndt2010/reports/1_09_10.pdf IS - Paper 4.02.18 SP - 1 EP - 10(?) AN - OPUS4-21465 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kupsch, Andreas T1 - Enhanced Spatial Resolution in 2D CT-Reconstruction without Filtered Back Projection: DIRECTT T2 - WCNDT 17 CY - Shanghai, China DA - 2008-10-26 PY - 2008 AN - OPUS4-18481 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kupsch, Andreas T1 - Optimierte Rohdatenanalyse faserbasierter Werkstoffe durch Weiterentwicklung des iterativen CT-Algorithmus DIRECTT T2 - Vortrag am Institut für Stochastik, Universität Ulm CY - Ulm, Germany DA - 2010-09-29 PY - 2010 AN - OPUS4-22160 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kupsch, Andreas T1 - X-ray laminographic inspection of sandwich shell segments for wind turbine rotor blades N2 - 3D structural investigations are described by X-ray laminography studies of sandwich shell segments, made of a PVC foam core, covered by non-crimp fabric glass fibre composite lay-ups processed by vacuum assisted resin infusion of epoxy. The specific scope of this study is to image transversal flaws within the foam core (joints) and of single ply overlaps. Test flaws were purposely implemented in order to simulate typical failure under cyclic load. In a dedicated test rig for shell structures, the flaw evolution/propagation is monitored by thermography and optical 3D inspection of deformation. Due to the unfavourable preconditions for classical computed tomography as of large aspect ratio, the samples were investigated by coplanar translational laminography. Its limited range of observation angles of ± 45°, results in anisotropic artefacts about the normal to the sample surface, but the typical flaws are well visualized in the as-prepared state, in a state of early damage, and in the repaired state. T2 - 12th European Conference on Non-Destructive Testing CY - Gothenburg, Sweden DA - 11.06.2018 KW - X-ray laminography KW - Wind turbine KW - Rotor blade PY - 2018 AN - OPUS4-45438 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kupsch, Andreas T1 - Compton-CT als Alternative zur Neutronentomographie? T2 - DACH Jahrestagung 2015 CY - Salzburg, Austria DA - 2015-05-11 PY - 2015 AN - OPUS4-33481 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Serrano-Munoz, Itziar A1 - Roveda, Ilaria A1 - Kupsch, Andreas A1 - Müller, Bernd R. A1 - Bruno, Giovanni T1 - Synchrotron X-ray refraction detects microstructure and porosity evolution during in-situ heat treatments N2 - For the first time, synchrotron X-ray refraction radiography (SXRR) has been paired with in-situ heat treatment to monitor microstructure and porosity evolution as a function of temperature. The investigated material was a laser powder bed fusion (LPBF) manufactured AlSi10Mg, where the initial eutectic Si network is known to disintegrate and spherodize into larger particles with increasing temperature. Such alloy is also prone to thermally induced porosity (TIP). We show that SXRR allows detecting the changes in the Si-phase morphology upon heating, while this is currently possible only using scanning electron microscopy. SXRR also allows observing the growth of pores, usually studied via X-ray computed tomography, but on much smaller fields-of-view. Our results show the great potential of in-situ SXRR as a tool to gain in-depth knowledge of the susceptibility of any material to thermally induced damage and/or microstructure evolution over statistically relevant volumes. KW - Synchrotron X-ray refraction radiography KW - Si network disintegration KW - Thermally induced porosity (TIP) KW - Laser powder bed fusion (LPBF) KW - Statistically relevant volumes KW - AlSi10Mg alloy PY - 2022 DO - https://doi.org/10.1016/j.msea.2022.142732 SN - 0921-5093 VL - 838 SP - 1 EP - 11 PB - Elsevier CY - Amsterdam AN - OPUS4-54297 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Shashev, Yury A1 - Kupsch, Andreas T1 - Talbot-Lau Röntgen-Interferometrie für die zerstörungsfreie Prüfung N2 - Im vergangenen Jahrzehnt sind gitterinterferometrische Röntgenabbildungen zunehmend in den Fokus des Interesses gerückt. Sie sind insbesondere dann Vorteil, wenn der in der Standardradiographie erreichbare Kontrast nicht genügt, schwach absorbierende Mikro- und Nanostrukturen abzubilden. Auf Kosten mehrerer Aufnahmen gestattet die Talbot-Lau Gitterinterferometrie, die Beiträge aus Absorption, Refraktion und (refraktiver) Streuung zu trennen. Dazu werden die Störungen der Interferenzmuster von Phasengittern ausgewertet. Im Gegensatz zu einer Vielzahl anderer refraktionsbasierter Abbildungsmethoden kann diese Technik mit konventionellen Röntgenröhren (mit divergenter, polychromatischer Strahlung) angewendet werden. Damit ist die Technik geeignet, typische ZfP-Fragestellungen zu lösen. Hier stellen wir Untersuchungen zur Effizienz von Phasengittern vor. Die Visibilität (d.h. die Höhe der Oszillation im Interferenzmuster) wird als Funktion verschiedener geometrischer Parameter verfolgt. Eine Rotation um die Achse parallel zu den Gitterstegen ändert die Form des Gitterprofils (d.h. die Verteilung der Phasenschiebungen). Die kontinuierliche Variation des Winkels und des Detektionsabstandes führt zur Identifikation von ausgezeichneten Kombinationen mit maximaler Visibilität, wobei die Abstände deutlich geringer sind als im Standardaufbau mit senkrechter Gitterbestrahlung. Unsere Studie umfasst Simulationen für monochromatische Quelle und den Vergleich zu experimentellen Ergebnissen mit der Synchrotronstrahlung. In der Literatur wurden die Vorteile der Talbot-Lau Interferometrie für die zerstörungsfreie Prüfung von Faserkompositen und Verbundwerkstoffen demonstriert. Hier werden als Beispiele Messungen an Aluminiumtitanat (Al2TiO5) Pulver gezeigt. T2 - DGZfP-Jahrestagung 2017 CY - Koblenz, Germany DA - 22.05.2017 KW - Gitterinterferometrische Röntgenabbildung KW - Phasengitter KW - Talbot-Lau Interferometrie KW - Zerstörungsfreie Prüfung PY - 2017 AN - OPUS4-40661 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kupsch, Andreas T1 - Tomographic Methods for Investigation of Fuel Cell Materials T2 - 2nd HZB Joint User's Meeting CY - Berlin, Germany DA - 2010-12-09 PY - 2010 AN - OPUS4-22864 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kupsch, Andreas T1 - Bestimmung der Mikrostruktur und Simulation des Schädigungs-verhaltens von lasergesintertem Polyamid 12 unter statischer Zugbelastung N2 - Um das Material- und Schädigungsverhalten von additiv gefertigtem Polyamid 12 (PA12) unter quasistatischer Belastung zu charakterisieren, wurden mechanische Tests und Experimente zur Bestimmung der Mikrostruktur durchgeführt. Die Proben wurden nach dem Prinzip des Selektiven Lasersinterns (SLS) hergestellt. Unter quasistatischer Belastung mit Haltezeiten ergab sich ein viskoplastisches Materialverhalten. Im Zugversuch wurde eine maximale Zugfestigkeit von 40.6 MPa und eine Bruchdehnung von 7.4% beobachtet. Mittels Digitaler Bildkorrelation (DIC) wurde die Ausbildung von Scherbändern während des Zugs nachgewiesen. Mittels Röntgenrefraktion wurde eine Erhöhung von inneren Oberflächen beobachtet, die senkrecht zur Zugrichtung orientiert sind. Die Analyse der Gesamtporosität aus Computertomographie-Messungen ergab keine Änderung infolge der Zugbelastung. Jedoch wurde eine bimodale Porengrößenverteilung und eine steigende Sphärizität festgestellt. Das Materialverhalten wurde mit den Ergebnissen des Zugversuchs nach dem Chaboche Modell [3] in sehr guter Übereinstimmung simuliert. Allerdings gestattet dieses Modell nicht, das Bruchverhalten einzuschließen. Daher wurde zur Simulation des Schädigungsverhaltens das Modell gemäß dem Ansatz von Gurson, Tvergaard und Needleman unter Berücksichtigung der mikrostrukturellen Parameter erweitert. Während das Chaboche Modell eine homogene Spannungsverteilung generiert, zeigt das erweiterte Modell die Ausbildung von Scher¬bändern und die korrekte Bruchdehnung. Der Schwerpunkt des Vortrages liegt auf den Röntgenverfahren zur experimentellen Bestimmung der Mikrostruktur. T2 - DGM-Symposium "Additive Fertigung in der Kunststoffindustrie" CY - Würzburg, Germany DA - 14.11.2019 KW - Additive Fertigung KW - Selektives Lasersintern KW - Polyamid 12 KW - Röntgenrefraktion KW - Computertomographie KW - Porosität PY - 2019 AN - OPUS4-49707 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bruno, Giovanni A1 - Kupsch, Andreas A1 - Serrano-Munoz, Itziar T1 - Absorption and refraction tomography: Characterization and Non-destructive Testing of Micro-structured Materials N2 - The combination of tomographic, microstructural data with other experimental techniques and with modeling is paramount, if we want to extract the maximum amount of information on material and component properties. In particular, quantitative image analysis, statistical approaches, direct discretization of tomographic reconstructions represent concrete possibilities to extend the power of the tomographic 3D representation to insights into the material and component performance. This logic thread holds equally for industrial and academic research, and valorizes expensive experiments such as those carried out at synchrotron sources, which cannot be daily repeated. I will show a few examples of possible use of X-ray tomographic data for quantitative assessment of damage evolution and microstructural properties, as well as for non-destructive testing. I will also show how X-ray refraction computed tomography (CT) can be highly complementary to classic absorption CT, being sensitive to internal interfaces. T2 - MPA Seminar 2024 CY - Stuttgart, Germany DA - 08.10.2024 KW - X-ray Refaction radiography KW - X-ray computed tomography KW - Damage KW - Composites KW - Large Scale facilites KW - Synchrotron PY - 2024 AN - OPUS4-61347 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -