TY - JOUR A1 - Flores, E. A1 - Idrees, F. A1 - Moussay, P. A1 - Viallon, J. A1 - Wielgosz, R. A1 - Fernández, T. A1 - Ramírez, S. A1 - Rojo, A. A1 - Shinji, U. A1 - Waldén, J. A1 - Sega, M. A1 - Sang-Hyub, O. A1 - Macé, T. A1 - Couret, C. A1 - Qiao, H. A1 - Smeulders, D. A1 - Guenther, F.R. A1 - Thorn, W.J. III A1 - Tshilongo, J. A1 - Ntsasa, N.G. A1 - Stovcík, V. A1 - Valková, M. A1 - Konopelko, L. A1 - Gromova, E. A1 - Nieuwenkamp, G. A1 - Wessel, R. M. A1 - Milton, M. A1 - Harling, A. A1 - Vargha, G. A1 - Tuma, Dirk A1 - Kohl, Anka A1 - Schulz, Gert T1 - Final report on international comparison CCQM-K74: Nitrogen dioxide, 10 µmol/mol N2 - There is a high international priority attached to activities which reduce NOx in the atmosphere. The current level of permitted emissions is typically between 50 µmol/mol and 100 µmol/mol, but lower values are expected in the future. Currently, ambient air quality monitoring regulations also require the measurement of NOx mole fractions as low as 0.2 µmol/mol. The production of accurate standards at these levels of mole fractions requires either dilution of a stable higher concentration gas standard or production by a dynamic technique, for example one based on permeation tubes. The CCQM-K74 key comparison was designed to evaluate the level of comparability of National Metrology Institutes' measurement capabilities and standards for nitrogen dioxide (NO2) at a nominal mole fraction of 10 µmol/mol. The measurements of this key comparison took place from June 2009 to May 2010. Seventeen laboratories took part in this comparison coordinated by the BIPM and VSL. The key comparison reference value was based on BIPM measurement results, and the standard measurement uncertainty of the reference value was 0.042 µmol/mol. This key comparison demonstrated that the results of the majority of the participants agreed within limits of ±3% relative to the reference value. The results of only one laboratory lay significantly outside these limits. Likewise this comparison made clear that a full interpretation of the results of the comparison needed to take into account the presence of nitric acid (in the range 100 nmol/mol to 350 nmol/mol) in the cylinders circulated as part of the comparison, as well as the possible presence of nitric acid in the primary standards used by participating laboratories. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA). DatesIssue 1A (Technical Supplement 2012) KW - Ringversuch KW - NO2 KW - Spurenverunreinigungen KW - Meßverfahren PY - 2012 DO - https://doi.org/10.1088/0026-1394/49/1A/08005 SN - 0026-1394 SN - 1681-7575 VL - 49 IS - 08005 SP - 1 EP - 117 PB - Inst. of Physics Publ. CY - Bristol AN - OPUS4-25927 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Flores, E. A1 - Idrees, F. A1 - Moussay, P. A1 - Viallon, J. A1 - Wielgosz, R. A1 - Fernández, T. A1 - Rojo, A. A1 - Ramírez, S. A1 - Aoki, N. A1 - Kato, K. A1 - Jeongsoon, L. A1 - Moon, D. A1 - Kim, J.-S. A1 - Harling, A. A1 - Milton, M. A1 - Smeulders, D. A1 - Guenther, F.R. A1 - Gameson, L. A1 - Botha, A. A1 - Tshilongo, J. A1 - Ntsasa, N.G. A1 - Valková, M. A1 - Konopelko, L. A1 - Kustikov, Y.A. A1 - Ballandovich, V. S. A1 - Gromova, E.V. A1 - Tuma, Dirk A1 - Kohl, Anka A1 - Schulz, Gert T1 - Final report of the pilot study CCQM-P110-B1: A comparison of nitrogen dioxide (NO2) in nitrogen standards at 10 µmol/mol by Fourier transform infrared spectroscopy (FT-IR) N2 - This pilot study compares the performance of participants in analyzing gas mixtures of nitrogen dioxide in nitrogen by comparison with in-house gravimetric standards using Fourier transformed infrared spectroscopy (FT-IR). In this study the same gas mixtures were used as in the key comparison CCQM-K74, which was designed to evaluate the level of comparability of National Metrology Institutes' measurement capabilities for nitrogen dioxide (NO2) at a nominal mole fraction of 10 µmol/mol. In the comparison CCQM-K74 most of the participants used chemiluminescence, with a small number using UV absorption or FT-IR spectroscopy, and thus it is of interest to improve understanding of the comparative performance of these techniques because they do not exhibit any cross-sensitivity to nitric acid (HNO3), which was known to be present in the mixtures used for the comparison. The results of this pilot study indicate good consistency and a level of agreement similar to that reported in the comparison CCQM-K74, demonstrating that FT-IR can be operated as a comparison method when calibrated with appropriate gas standards and can achieve similar measurement uncertainties to chemiluminescence and UV absorption techniques. An additional pilot study, CCQM-P110-B2, was conducted on the same gas mixtures in parallel with this pilot study. The second study addressed FT-IR spectroscopy when used to measure the gas mixtures with respect to reference spectra. The results of this second study will be reported elsewhere. Main text. To reach the main text of this paper, click on Final Report. The final report has been peer-reviewed and approved for publication by the CCQM-GAWG. DatesIssue 1A (Technical Supplement 2012) KW - Ringversuch KW - NO2 KW - Spurenverunreinigungen KW - FT-IR-Spektroskopie PY - 2012 DO - https://doi.org/10.1088/0026-1394/49/1A/08006 SN - 0026-1394 SN - 1681-7575 VL - 49 IS - 08006 SP - 1 EP - 76 PB - Inst. of Physics Publ. CY - Bristol AN - OPUS4-25928 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Aristia, Gabriela A1 - Bäßler, Ralph A1 - Nofz, Marianne A1 - Sojref, Regine A1 - Kohl, Anka T1 - Short-term exposure tests of ɣ-Al2O3 Sol-gel coating on X20Cr13 in artificial geothermal waters with different pH N2 - The suitability of an Al2O3 coating for corrosion protection on X20Cr13 was evaluated in various artificial geothermal brines, focusing on the influence of different pH (4, 6 and 8) and their chemical compositions on the coating properties. All experiments were performed in the laboratory using autoclaves at 150 ◦C and 1 MPa in deaerated condition for 1 and 7 days. Results showed that the pH of geothermal waters is the most detrimental factor in the transformation of ɣ-Al2O3 and its protective abilities. Delaminations were found in the Coating exposed to geothermal brines with pH 4. FTIR spectra indicated a transformation of ɣ-Al2O3 to boehmite AlOOH after exposure to pH 4 and 6, and bayerite Al(OH)3 was formed after exposure to pH 8. Different Crystal structures of the hydrated Al2O3 also contribute to the stability of the coatings, observed by the SEM- EDX of the surface and cross-section of coatings. This study indicated that ɣ-Al2O3 sol-gel coating presents a promising aspect of corrosion protection in geothermal environment with a neutral pH. KW - Al2O3 KW - Corrosion KW - Coating KW - Martensitic steel PY - 2021 DO - https://doi.org/10.1016/j.geothermics.2021.102193 SN - 0375-6505 VL - 96 SP - 102193 PB - Elsevier Ltd. CY - Amsterdam AN - OPUS4-52931 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Vogel, Christian A1 - Kohl, Anka A1 - Adam, Christian T1 - Spectroscopic investigation in the mid- and far-infrared regions of phosphorus fertilizers derived from thermochemically treated sewage sludge ash N2 - Inorganic phosphorus and nitrogen-phosphorus-potassium (NPK) fertilizers based on phosphates from thermochemically treated sewage sludge ash were analyzed using mid-infrared (mid-IR) and far-infrared (FIR) spectroscopy. The different compounds present in the fertilizers were qualitatively determined with the help of recorded reference spectra of pure substances. Differentiation between various phosphates and other compounds such as sulfates, nitrates, and oxides was possible using combined interpretation of the mid-IR and FIR spectra. The results are in agreement with previous X-ray diffraction (XRD) measurements of the same samples. The main phosphate phases detected were NH4H2PO4, MgHPO4·3H2O, Mg3(PO4)2, Ca5(PO4)5Cl, CaHPO4·2H2O, Ca(H2-PO4)2·H2O, and AlPO4. Furthermore, K2SO4, NH4NO3, Fe2O3, and SiO2 were identified in the IR spectra. However, ammonium and sulfate compounds were only identified in the mid-IR region but were not detectable in the FIR region. KW - Sewage sludge ash KW - Fertilizer KW - P-fertilizer KW - Phosphorus compounds KW - Mid-infrared spectroscopy KW - Far-infrared spectroscopy PY - 2011 DO - https://doi.org/10.1366/10-06168 SN - 0003-7028 SN - 1943-3530 VL - 65 IS - 3 SP - 265 EP - 271 PB - Society for Applied Spectroscopy CY - Frederick, Md. AN - OPUS4-23270 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Torge, Manfred A1 - Sabel, Martin A1 - Feldmann, Ines A1 - Kohl, Anka T1 - Naturwissenschaftliche Untersuchungen im Rahmen des Projektes 'Konservierung mittelalterlicher Glasmalerei im Kontext spezieller materieller und umweltbedingter Gegebenheiten' N2 - Nachsicherung geschädigter Zaponlack-Wachs-Sicherungen an den um 1410/20 entstandenen Glasmalereien des Helenafensters nord VIII am Erfurter Dom - Untersuchungen zu Schadensursachen, Schadensphänomenen, Methoden der Nachbehandlung und des Monitorings KW - Glasmalerei KW - Restaurierung KW - Zaponlack PY - 2011 SN - 978-3-8167-8470-8 VL - D 1012 SP - 36 EP - 75 PB - Fraunhofer IRB Verl. CY - Stuttgart AN - OPUS4-23631 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Rabin, Ira A1 - Schütz, R. A1 - Kohl, Anka A1 - Wolff, Timo A1 - Tagle, R. A1 - Pentzien, Simone A1 - Hahn, Oliver A1 - Emmel, S. T1 - Identification and classification of historical writing inks in spectroscopy: a methodological overview N2 - The identification of the type of ink should be among the primary goals of manuscript description. Several techniques of instrumental analysis are available, and new tools have been appearing on the market, the main development having been to more portability and user friendliness. In this article, we would like to give an overview of several existing methods and of their respective advantages and the results (on the example of a Coptic manuscript) that can be obtained with their help. KW - Archaeometry KW - Non-destructive testing KW - Spectroscopy KW - Manuscript studies PY - 2012 SN - 2078-3841 VL - 3 SP - 26 EP - 30 PB - ESF CY - Strasbourg AN - OPUS4-26940 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Köppen, Robert A1 - Emmerling, Franziska A1 - Kohl, Anka A1 - Becker, Roland T1 - Delta-Hexabromocyclododecane N2 - (1R,2S,5R,6S,9S,10R)-Hexabromocyclododecane (C12H18Br6, d-HBCD) was crystallized from acetonitrile. The C—Br distances range from 1.962 (8) to 1.982 (8) Å and intermolecular Br...Br contacts contribute to the formation of layers. PY - 2007 DO - https://doi.org/10.1107/S1600536807026396 SN - 1600-5368 VL - 63 IS - 7 SP - o3105 PB - Munksgaard CY - Copenhagen AN - OPUS4-15048 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -