TY - GEN A1 - Ehrig, Karsten A1 - Staude, Andreas A1 - Goebbels, Jürgen A1 - Bartscher, M. A1 - Koch, M. A1 - Neukamm, M. ED - Kastner, J. T1 - Evaluierung von Testkörpern zur Strahlaufhärtungskorrektur beim dimensionellen Messen mit Computertomographie T2 - Industrielle Computertomografie Tagung CY - Wels, Österreich DA - 2010-09-27 KW - Testkörper KW - Strahlaufhärtung KW - CT KW - Dimensionelles Messen PY - 2010 SN - 978-3-8322-9418-2 SN - 1610-4773 SP - 181 EP - 186 PB - Shaker Verlag GmbH AN - OPUS4-22033 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Staude, Andreas A1 - Goebbels, Jürgen A1 - Bartscher, M. A1 - Hilpert, U. A1 - Koch, M. A1 - Reinhart, C. T1 - Genauigkeitssteigerung der Defekterkennung in Gussteilen mit Computertomographie (CT) am Beispiel eines Aluminium-Zylinderkopfsegments T2 - DACH-Jahrestagung 2008 - Zerstörungsfreie Materialprüfung, ZfP in Forschung, Entwicklung und Anwendung CY - St. Gallen, Schweiz DA - 2008-04-28 PY - 2008 SN - 978-3-940283-09-2 IS - DGZfP-BB 113 (Di.2.A.3) SP - 1 EP - 7 AN - OPUS4-18297 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Staude, Andreas A1 - Ehrig, Karsten A1 - Goebbels, Jürgen A1 - Bartscher, M. A1 - Hilpert, U. A1 - Koch, M. T1 - Methode und Prüfkörper zum Nachweis von Gussdefekten in Aluminiumbauteilen mit Computertomographie T2 - DGZfP-Jahrestagung 2009 CY - Münster, Deutschland DA - 2009-05-18 PY - 2009 SN - 978-3-940283-16-0 IS - DGZfP-BB 115 (Mi.4.B.2) SP - 1 EP - 8 AN - OPUS4-20728 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Staude, Andreas A1 - Bartscher, M. A1 - Ehrig, Karsten A1 - Goebbels, Jürgen A1 - Koch, M. A1 - Neuschaefer-Rube, U. A1 - Nötel, Jörg T1 - Quantification of the capability of micro-CT to detect defects in castings using a new test piece and a voxel-based comparison method N2 - We present a modified aluminium casting which is especially suited as test piece for measuring casting defects and the geometry by means of cone-beam micro-focus X-ray systems, and which may become a reference standard for dimensional measurements and defect detection. To obtain a test piece with inner geometries measured by tactile means, we divided a small aluminium cylinder head into four pieces in such a way that most inner surfaces can be reached with a tactile probe. Reference geometries (spheres and cylinders) were applied to define a coordinate system for aligning the measurements in the disassembled and re-assembled state. The four pieces were re-assembled after the tactile measurement. The test piece also contains casting defects. In order to be able to use the assembled cylinder head as reference sample for defect detection, measurements with higher spatial resolution and better signal-to-noise ratio were performed on the single parts. For improving the reliability of the reference measurements, CT measurements of each part were carried out in three different orientations, and the individual defect detections were combined to obtain a reference data set with a high probability of defect detection and a low rate of erroneous detections. A new method for comparing the defect detection in a CT measurement to a reference data set is demonstrated, which provides individual information on every detected flaw. We discuss the results of measurements in the assembled state with respect to the reference data for flaw detection. KW - X-ray tomography KW - Casting KW - Defects KW - Porosity PY - 2011 DO - https://doi.org/10.1016/j.ndteint.2011.05.006 SN - 0963-8695 VL - 44 IS - 6 SP - 531 EP - 536 PB - Butterworth-Heinemann CY - Oxford AN - OPUS4-24028 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ehrig, Karsten A1 - Bartscher, M. A1 - Goebbels, Jürgen A1 - Koch, M. A1 - Staude, Andreas T1 - Einfluss von Materialkombinationen auf das dimensionelle Messen mit Mikro-Computertomographie am Beispiel eines werkstücknahen Testkörpers N2 - Die Computertomographie (CT) hat sich als dimensionelle Messmethode in der industriellen Produktion etabliert. Durch Messungen an speziellen Prüfkörpern ist es möglich, quantitative Informationen über die metrologischen Eigenschaften dimensioneller Messungen zu erhalten. In dieser Arbeit wird einen Aluminium-Guss-Prüfkörper (120 mm x 90 mm x 60 mm) benutzt, mit dem – in der vorliegender Form – auch der Einfluss von Materialien unterschiedlicher Schwächung auf dimensionelle CT-Messungen untersucht werden kann. Der Prüfkörper ist in vier Segmente zerteilt, so dass auch innenliegende, raue Gussfreiformflächen der taktilen Koordinatenmessung zugänglich sind. Durch adaptierte Rubinkugeln als Referenzstrukturen können die CT-Messdaten in taktile Referenz-Koordinatensysteme überführt werden. Um den Einfluss von Materialien unterschiedlicher Schwächung auf das dimensionelle Messen mit CT zu untersuchen, wurden stärker schwächende ZTA-Störkugeln (Zirconia Toughened Alumina) mit zur Ausrichtung geeigneter Symmetriebrechung in der Nähe von ausgewählten taktilen Messstellen angebracht. Zur Bewertung der Messabweichungen dienen taktile Referenzmessungen an den ZTA-Kugeln sowie taktile Messungen an den Freiformflächen des Gussteils, wobei durch ein iteratives Antastverfahren eine verbesserte Erfassung der Geometrie auch bei starken lokalen Oberflächenkrümmungen sichergestellt wird. T2 - DGZfP-Jahrestagung 2011 CY - Bremen, Germany DA - 30.05.2011 KW - Mikro-CT KW - Dimensionelles Messen KW - Testkörper KW - Multimaterial PY - 2011 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-248878 SN - 978-3-940283-33-7 IS - DGZfP-BB 127 (Di.1.B.2) SP - 1 EP - 6 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) AN - OPUS4-24887 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -