TY - CONF A1 - Schälike, Stefan A1 - Mishra, Kirti Bhushan A1 - Malow, Marcus A1 - Berger, Anka A1 - Wehrstedt, Klaus-Dieter A1 - Schönbucher, A. ED - Pierucci, S. ED - Klemes, J.J. ED - De Rademaeker, E. ED - Fabiano, B. ED - Buratti, S.S. T1 - Mass burning rate of a large TBPB pool fire - experimental study and modeling N2 - Data and prediction for the mass burning rate of a tert-butyl-peroxy-benzoat (TBPB) pool fire (pool diameter = 3 m) is presented. The mass burning rates of TBPB fires are up to six times higher and less dependent on pool diameter compared to hydrocarbon pool fires caused by an additional heat release rate due to exothermic decomposition reaction in the liquid phase. This heat release rate is calculated using a 1st order reaction kinetic obtained from micro calorimetric measurements. A new model is derived considering the heat release rate due to the decomposition reaction which is shown to be 100 % of the heat release rate radiated to the pool surface. With the presented model, including also physical quantities, especially the limiting fuel concentration for upward flame propagation, it is possible to predict the mass burning rates of large TBPB pool fires. The predicted values are in very good agreement with the experiments. T2 - 14th International symposium on loss prevention and safety promotion in the process industries CY - Florence, Italy DA - 12.05.2013 KW - Mass burning rate KW - TBPB (tert-butyl-peroxy benzoat) KW - Pool fire KW - Experimental study KW - Modeling PY - 2013 SN - 978-88-95608-22-8 DO - https://doi.org/10.3303/CET1331143 SN - 1974-9791 N1 - Serientitel: Chemical engineering transactions – Series title: Chemical engineering transactions IS - 31 SP - 853 EP - 858 PB - AIDIC, Associazione Italiana di Ingegneria Chimica CY - Milano AN - OPUS4-28501 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wehrstedt, Klaus-Dieter T1 - Peroxyacetic acids-Properties and Classification T2 - Peracetic Acid Registration Group (PAR) Meeting CY - Berlin, Germany DA - 2013-04-23 PY - 2013 AN - OPUS4-28541 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wehrstedt, Klaus-Dieter T1 - Odyssey after loss-MSC "Flaminia" T2 - IGUS EOS Meeting CY - Verneuil en Halatte, France DA - 2013-04-17 PY - 2013 AN - OPUS4-28546 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schälike, Stefan A1 - Mishra, Kirti Bhushan A1 - Wehrstedt, Klaus-Dieter A1 - Schönbucher, A. T1 - Limiting distances for flame merging of multiple n-heptane and di-tert-butyl peroxide pool fires N2 - Experiments to determine the limiting distances for flame merging of multiple pool fires are presented. As model substances n-heptane and di-tert-butyl peroxide are used. Laboratory scale tests with a Diameter d = 6 cm and relative distances between the pools of 0.08 ≤ D/d ≤ 4 are described and complemented with field experiments with a diameter d = 1.5 m and relative distances between the pools of 0.17 ≤ D/d ≤ 1. Three regions for flame merging are observed and limiting distances are determined. A merging Region with the limiting distance Dmerg/d within which all flames merge together over the complete burning time. A transition region with the limiting distance Dtran/d within which some flames merge together while other flames are separated from each other. A separated region within which all flames are completely separated from each other. A correlation against the number of burning pools is presented to predict the limiting distances Dmerg/d und Dtran/d. T2 - ICheaP-11 - 11th International conference on chemical & process engineering CY - Milan, Italy DA - 02.06.2013 KW - Multiple fires KW - Flame merging KW - Mass burning rate KW - Limiting distances KW - Pool fire KW - Experimental study KW - Di-tert-butyl peroxide PY - 2013 SN - 978-88-95608-23-5 DO - https://doi.org/10.3303/CET1332021 SN - 1974-9791 N1 - Serientitel: Chemical engineering transactions – Series title: Chemical engineering transactions IS - 32 SP - 121 EP - 126 PB - AIDIC, Associazione Italiana di Ingegneria Chimica CY - Milan AN - OPUS4-28646 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Mishra, Kirti Bhushan A1 - Wehrstedt, Klaus-Dieter T1 - Diffusive burning characteristics of peroxy-fuels N2 - The diffusive burning characteristics of four peroxy-fuels (usually known as liquid organic peroxides) and one hydrocarbon fuel are experimentally investigated targeting alternative fuels (or as additives to conventional fuels) for the future. Measurements are performed in form of pool fires with pool diameters in the range between 1 cm and 1 m. Mass, momentum and energy transfer studies are carried out by measuring the mass burning rate, flame length, flame temperature and radiation heat transfer across the liquid fuel and gaseous flame. It has been shown that comparatively much less mass of peroxy-fuels and pressure drop (required to maintained the flow) of fuel are required to produce a given heat flux. The momentum delivered by the peroxy-fuel vapours are order of magnitude higher than for hydrocarbons making the visibility of flame to be 4–5 times larger. A heat balance analysis shows that the total heat release rate of a peroxy-fuel fire is contributed equally by convection and radiation. Finally, the three E's (Efficiency, Economy and Emission) are discussed in the context of present experimental results followed by some recommendations concerning safe handling of the proposed fuels. KW - Burning characteristics KW - Peroxy-fuels KW - Hydrocarbons KW - Pool fires KW - Three E’s PY - 2013 DO - https://doi.org/10.1016/j.fuel.2013.05.031 SN - 0016-2361 VL - 113 SP - 158 EP - 164 PB - Elsevier CY - Amsterdam AN - OPUS4-28711 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Vela-Wallenschus, Iris A1 - Schälike, Stefan A1 - Mishra, Kirti Bhushan A1 - Wehrstedt, Klaus-Dieter A1 - Schönbucher, A. T1 - Kritische thermische Abstände bei wechselwirkenden KW- und Peroxid-Poolfeuern N2 - In verfahrenstechnischen Anlagen kann es während des Umgangs, des Transports und der Lagerung durch Freisetzung und anschliesender Zündung von brennbaren Flüssigkeiten zu Lachen-, Pool- oder Tankfeuern kommen. Die sich ausbildenden Feuer konnen große Schäden an benachbarten verfahrenstechnischen Anlagen und Personen verursachen. Im Unterschied zu Einzelfeuern sind multiple Pool- und Tankfeuer aufgrund ihrer Wechselwirkungseffekte sicherheitstechnisch von besonderer Bedeutung. Mit Di-tert-butyl-peroxid (DTBP) und n-Heptan als Leitsubstanzen werden Labor- und Feldexperimente (d ≤ 1.5 m) mit wechselwirkenden Poolflammen (N ≤ 9) in einer Matrixanordnung bei relativen horizontalen Abständen D/d zwischen den Pools im Bereich 0.16 ≤ D/d ≤ 4 durchgeführt. Die Phänomene der Flammenverschmelzung (Flammenfusion) in Abhängigkeit vom Poolabstand D/d werden experimentell untersucht und modelliert. T2 - 11. Fachtagung Anlagen-, Arbeits- und Umweltsicherheit CY - Köthen, Germany DA - 07.11.2013 KW - Wechselwirkende Poolfeuer KW - KW-Poolfeuer KW - Peroxid-Poolfeuer KW - Sicherheitsabstände KW - Spezifische Ausstrahlung KW - Bestrahlungsstärke PY - 2013 SN - 978-3-86011-058-4 N1 - Geburtsname von Vela-Wallenschus, Iris: Vela, I. - Birth name of Vela-Wallenschus, Iris: Vela, I. IS - P-06 SP - 1 EP - 17 AN - OPUS4-29549 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schälike, Stefan A1 - Mishra, Kirti Bhushan A1 - Ziemann, Sylvia A1 - Wehrstedt, Klaus-Dieter A1 - Schönbucher, A. ED - Beyer, M. ED - Stolz, T. T1 - Massenabbrandraten organischer Peroxide unter besonderer Berücksichtigung der thermischen Stabilität N2 - Die Flüssigkeitstemperatur Temperatur in der flüssigen Phase unmittelbar im Grenzbereich zur Gasphase während eines Abbrandes organischer Peroxide überschreitet die Onset-Temperatur der beginnenden exothermen Zersetzungsreaktion des Peroxids, so dass diese zu berücksichtigen ist. Für die Peroxide Di-tert-butyl-Peroxid (DTBP) und tert-butyl-peroxybenzoat (TBPB) muss daher bei der Berechnung des Wärmerückstromes ein zusätzlicher Term für die Zersetzung in der Flüssigkeit additiv ergänzt werden. Der Umsatz der Zersetzungsreaktion wird unter den Bedingungen eines CSTR modelliert und erfolgt auf Basis einer Reaktionskinetik 1. Ordnung. Es kann gezeigt werden, dass der Wärmestrom in einem DTBP-Poolfeuer ≈ 40 % und einem TBPB-Poolfeuer ≈ 100 % des Wärmerückstromes durch Wärmestrahlung entspricht. Durch Q-Punkt-d können die vergleichsweise hohen Massenabbrandraten und die relative Unabhängigkeit der Massenabbrandraten vom Pooldurchmesser erklärt werden. Über eine Energiebilanz wird ein Modell basierend auf physikalischen Parametern entwickelt, das die Massenabbrandraten großer Poolfeuer, in sehr guter Übereinstimmung mit den experimentellen Ergebnissen, vorhersagt. T2 - 13. BAM-PTB-Kolloquium zur chemischen und physikalischen Sicherheitstechnik CY - Braunschweig, Germany DA - 18.06.2013 KW - Poolfeuer KW - Massenabbrandrate KW - Organische Peroxide KW - Thermische Stabilität KW - Onset-Temperatur PY - 2013 SN - 978-3-95606-062-5 DO - https://doi.org/10.7795/210.20130801E SN - 1868-5838 SP - 40 EP - 47 AN - OPUS4-29815 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Mishra, Kirti Bhushan A1 - Wehrstedt, Klaus-Dieter A1 - Krebs, Holger T1 - Amuay refinery disaster: The aftermaths and challenges ahead N2 - Amuay refinery disaster (2012) is another recent example of Vapor Cloud Explosion (VCE) and fire accidents preceded by Buncefield (2005), Puerto-Rico (2009) and Jaipur (2009), respectively [9]. The incident has left many safety issues behind which must be repeatedly addressed. Unfortunately, the lessons taught by previous similar events are just not understood carefully. It reveals that the proper safety measures for such facilities were either underestimated or were not accounted seriously. Consequently, the resulting overpressures from explosion and the subsequent thermal radiation from tank fires have once again proved to be disastrous to both mankind and infrastructure. This article highlights the aftermaths of Amuay incident and addresses the challenges put forward by it. Furthermore, a comparative study is performed between such incidents to analyze the similarities and how they could have been avoided. KW - Refinery disaster KW - Vapor cloud explosion KW - Fire KW - Safety distance KW - Overpressure KW - Radiation PY - 2014 DO - https://doi.org/10.1016/j.fuproc.2013.10.025 SN - 0016-2361 SN - 0378-3820 SN - 1873-7153 VL - 119 SP - 198 EP - 203 PB - Elsevier CY - Amsterdam AN - OPUS4-29816 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schmidt, Martin A1 - Scheid, Marc A1 - Seifert, Alexander A1 - Böhme, Thilo A1 - Wehrstedt, Klaus-Dieter A1 - Bulin, Michael ED - Beyer, M. ED - Stolz, T. T1 - Erweiterung der GSBL-Datenbank um sicherheitstechnische Kenngrößen brennbarer Stäube - Erstellung von Staubgruppen und Ableiten bewerteter Bandbreiten N2 - Die Beurteilung des Gefahrenpotentials brennbarer Stäube erfolgt üblicherweise mit Hilfe so genannter sicherheitstechnischer Kenngrößen (STK). Häufig werden hierfür in Datenbanken bereitgestellte Werte in der Vergangenheit untersuchter Stäube herangezogen. Insbesondere aufgrund stofflicher Unterschiede der untersuchten Stäube sind erhebliche Streuungen der ermittelten STK in Datenbanken enthaltener namentlich identischer Stäube festzustellen. Die Verwendung der Daten von Einzelstäuben kann daher zu unsicheren Einschätzungen hinsichtlich des Brand- und Explosionsschutzes führen. Vorgestellt wird ein Konzept, Stäube zu praxisrelevanten Gruppen zusammenzufassen und bewertete Bandbreiten sicherheitstechnischer Kenngrößen anzugeben. Die im Rahmen eines vom Sächsischen Landesamt für Umwelt, Landwirtschaft und Geologie, Dresden, geförderten Vorhabens generierten Staubgruppen und zugehörigen Bandbreiten der STK stehen in der Datenbank GSBLpublic für die freie Nutzung zur Verfügung. T2 - 13. BAM-PTB-Kolloquium zur chemischen und physikalischen Sicherheitstechnik CY - Braunschweig, Germany DA - 18.06.2013 KW - Sicherheitstechnische Kenngrößen KW - Stäube KW - Staubexplosionen KW - Datenbank KW - Brand- und Explosionsgefahren PY - 2013 SN - 978-3-95606-062-5 DO - https://doi.org/10.7795/210.20130801U SN - 1868-5838 SP - 170 EP - 177 AN - OPUS4-29822 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wehrstedt, Klaus-Dieter A1 - Filippou, A.C. A1 - Portius, P. A1 - Neumann, D.U. T1 - Das Hexaazidogermanat(IV)-Ion - Synthesen, Strukturen und Reaktionen PY - 2000 DO - https://doi.org/10.1002/1521-3757(20001201)112:23<4524::AID-ANGE4524>3.0.CO;2-S SN - 0044-8249 SN - 0932-2140 SN - 1521-3757 VL - 112 IS - 23 SP - 4524 EP - 4527 PB - Wiley-VCH CY - Weinheim AN - OPUS4-1060 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Rudolph, Michael A1 - Wehrstedt, Klaus-Dieter A1 - Wandrey, Peter-Andreas T1 - Lagerung fester organischer Peroxide - Entwicklung eines Brandtests in kleinem Maßstab PY - 2001 SN - 0025-5300 VL - 43 IS - 10 SP - 411 EP - 416 PB - Carl Hanser Verlag CY - München AN - OPUS4-1185 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wehrstedt, Klaus-Dieter T1 - UN flow chart for organic peroxides and self-reactive substances - test results on formulations accepted for the transport in tanks and IBC's T2 - Energetic and Oxidising Substances (EOS) working group meeting CY - Buxton, England, UK DA - 2000-04-10 PY - 2000 AN - OPUS4-1523 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wehrstedt, Klaus-Dieter T1 - Identifizierung gefährlich exotherm zersetzlicher Stoffe T2 - DECHEMA-Kurs "Sicherheit von chemischen Reaktionen" CY - Berlin und Frankfurt am Main, Deutschland DA - 2001-10-10 PY - 2001 AN - OPUS4-1503 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Steidinger, Manfred A1 - Wehrstedt, Klaus-Dieter T1 - Nicht gleich in die Luft gehen - Bei Transport und Lagerung von Explosivstoffen zu beachten PY - 1998 SN - 0016-5808 VL - 43 IS - 6 SP - 34 EP - 36 PB - Storck CY - Hamburg AN - OPUS4-1504 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Wandrey, Peter-Andreas A1 - Wehrstedt, Klaus-Dieter ED - Kreysa, G. T1 - Sensibilisierung flüssiger organischer Peroxide gegen Detonationsstoß durch Kavitation - überzogenes oder praxisrelevantes Prüfverfahren? T2 - 35. Tutzing-Symposion CY - Tutzing, Deutschland DA - 1997-03-10 PY - 1997 SN - 3-926959-89-4 SN - 0934-4969 N1 - Serientitel: Praxis der Sicherheitstechnik – Series title: Praxis der Sicherheitstechnik IS - 4 SP - 133 EP - 146 PB - DECHEMA CY - Frankfurt am Main AN - OPUS4-1505 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Wehrstedt, Klaus-Dieter A1 - Wandrey, Peter-Andreas ED - Frobese, D.-H. ED - Krämer, H. T1 - Abbrandverhalten von flüssigen explosionsfähigen Stoffen in Abhängigkeit von der Pool-Größe T2 - 6. Sicherheitstechnische Vortragsveranstaltung über Fragen des Explosionsschutzes ; 107. PTB-Seminar CY - Braunschweig, Deutschland DA - 1993-09-07 PY - 1993 SN - 3-89429-359-4 SN - 0341-6739 IS - W-54 SP - 97 EP - 108 PB - Wirtschaftsverl. NW CY - Bremerhaven AN - OPUS4-1506 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wehrstedt, Klaus-Dieter A1 - Heitkamp, D. A1 - Klais, O. A1 - Wildner, W. T1 - Self-reactive substances, type G - Candidates for Class 4.2? T2 - Energetic and Oxidising Substances (EOS) working group meeting CY - Washington, DC, USA DA - 2001-03-12 PY - 2001 AN - OPUS4-1508 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wehrstedt, Klaus-Dieter A1 - Knorr, Annett T1 - Miniautoclave - test results on organic peroxides and self-reactive substances T2 - Energetic and Oxidising Substances (EOS) working group meeting CY - Washington, DC, USA DA - 2001-03-12 PY - 2001 AN - OPUS4-1509 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Rudolph, Michael A1 - Wehrstedt, Klaus-Dieter A1 - Zemke, Gerhard-Reinhard T1 - Organische Peroxide in Großpackmitteln - Berechnung des Aufheizverhaltens eines im Außenfeuer stehenden IBC mit Hilfe von CFD-Methoden T2 - Tagung "Sicherheitsgerechtes Auslegen von Chemieapparaturen" CY - Frankfurt am Main, Deutschland DA - 2001-11-21 PY - 2001 AN - OPUS4-1511 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schreck, Andreas A1 - Knorr, Annett A1 - Wehrstedt, Klaus-Dieter A1 - Gmeinwieser, T. A1 - Steinbach, J. T1 - Sicherheitstechnische Untersuchungen zur Alkylierung von Wasserstoffperoxid mit verschiedenen Alkoholen T2 - 34. Sitzung des DECHEMA-Arbeitsausschusses "Sicherheitstechnische Kenngrößen" CY - Frankfurt am Main, Deutschland DA - 2001-05-17 PY - 2001 VL - 34 AN - OPUS4-1512 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wehrstedt, Klaus-Dieter T1 - Selbstzersetzliche Stoffe - Einstufung und Klassifizierung T2 - Schulungsveranstaltung CY - Pinneberg, Deutschland DA - 2001-04-10 PY - 2001 AN - OPUS4-1513 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wehrstedt, Klaus-Dieter T1 - Testing and classification of new reactive substances T2 - Energetic and Oxidising Substances (EOS) working group meeting CY - Washington, DC, USA DA - 2001-03-12 PY - 2001 AN - OPUS4-1514 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wehrstedt, Klaus-Dieter T1 - Implementation of general n.o.s. entries into Class 3 and Division 4.1 (related substances and desensitized explosives) T2 - OECD-IGUS Energetic and Oxidising Substances (EOS) Working Group Meeting CY - Washington, D.C., USA DA - 2001-03-12 PY - 2001 AN - OPUS4-1515 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -