TY - CONF A1 - Kemmlein, Sabine T1 - Emission of Flame Retardants from Consumer Products and Building Materials T2 - Indoor Air 2002 CY - Monterey, CA, USA DA - 2002-06-30 PY - 2002 AN - OPUS4-5933 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kemmlein, Sabine T1 - Analysing emissions of flame retardants into the indoor atmosphere T2 - Konferenz "flame retardants for Electrical Applications" CY - Brussels, Belgium DA - 2005-01-25 PY - 2005 AN - OPUS4-11445 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kemmlein, Sabine A1 - Rockstroh, Jens A1 - Jann, Oliver ED - Reichl, H. T1 - Investigation on emissions of volatile and semivolatile compounds (VOC, SVOV), dust and ozone from electronic consumer products T2 - Joint International Congress and Exhibition Electronics Goes Green 2004+ CY - Berlin, Germany DA - 2004-09-06 KW - Emission test chamber KW - Emission test cells KW - VOC KW - SVOC KW - Flame retardants KW - Ozone KW - Dust KW - Hardcopy devices KW - Electronics PY - 2004 SP - 1051 EP - 1052 PB - Fraunhofer IRB Verl. CY - Stuttgart AN - OPUS4-5047 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Kemmlein, Sabine A1 - Bergmann, Meike A1 - Jann, Oliver T1 - Probenaufbereitungs- und Analyseverfahren für Flammschutzmittel (Pentabromdiphenylether, Octabromdiphenylether) in Erzeugnissen (Forschungsbericht 202 67 300 / UBA-FB 000839) N2 - Im Rahmen der Richtlinie 2003/11/EG zur 24. Änderung der Richtlinie 76/769/EWG wurde ein Grenzwert von 0,1 Gewichts-% für penta- und octabromierte Diphenylether in Erzeugnissen festgelegt. Zur Überprüfung dieses Grenzwertes wurde ein Standardanalyseverfahren zur quantitativen Bestimmung von ausgewählten Pentabromdiphenylethern (PentaBDE-Isomere) und Octabromdiphenylethern (OctaBDE-Isomere) in Polymeren mit Hilfe der Gaschromatographie-Massenspektrometrie (GC/MS) entwickelt. Zur Verfahrensentwicklung wurden folgende Isomere ausgewählt: BDE85 (2,2’,3,4,4’-PentaBDE), BDE99 (2,2’,4,4’,5- PentaBDE), BDE100 (2,2’,4,4’,6-PentaBDE), BDE203 (2,2’,3,4,4’,5,5’,6-OctaBDE), BDE196 (2,2’,3,3’,4,4’,5,6’-OctaBDE) und BDE197 (2,2’,3,3’,4,4’,6,6’-OctaBDE). Vorbereitend wurden folgende Modellpolymere hergestellt: Polyurethan (PUR-H) mit 0,1 Gew.-% Summe PentaBDEIsomere, Epoxidharz (EP) mit 0,1 Gew.-% Summe PentaBDE-Isomere, Polystyrol (PS) und Acrylnitril-Butadien-Styrol- Copolymer (ABS) mit jeweils 0,1 Gew.-% Summe OctaBDE-Isomere. Im Rahmen des Projektes wurde ein Ringversuch mit 18 Teilnehmern durchgeführt, bei dem die genannten Polymere dem Standardanalyseverfahren unterzogen wurden. Der Ringversuch wurde zwischen dem 01. Juni und 30. November 2004 veranstaltet. Die Datenauswertung erfolgte in Anlehnung an DIN ISO 5725-2:2002-12 „Genauigkeit (Richtigkeit und Präzision) von Messverfahren und Messergebnissen, Teil 2: Grundlegende Methode für die Ermittlung der Wiederhol- und Vergleichpräzision eines vereinheitlichten Messverfahrens“. Folgende Mittelwerte der Ermittlungsergebnisse sowie Standardabweichungen wurden bestimmt: 1,09 ± 0,16 mg g-1 (15 %) (Summe PentaBDE-Isomere/EP), 1,3 ± 0,19 mg g-1 (15 %) (Summe PentaBDE-Isomere/PUR-H), 0,99 ± 0,27 mg g-1 (27 %) (Summe OctaBDEIsomere/PS), 0,42 ± 0,11 mg g-1 (26 %) (Summe OctaBDE-Isomere/ABS). Als statistische Kennzahlen für das Standardanalyseverfahren wurde folgende Parameter ermittelt: Für PentaBDE-Isomere in EP wurde eine Wiederholstandardabweichung von srj = 0,044 mg g-1 (4,0 %) und eine Vergleichstandardabweichung sRj = 0,167 mg g-1 (15 %) bestimmt. Für PentaBDE-Isomere in PUR-H ergab sich für srj = 0,038 mg g-1 (2,9 %) und sRj = 0,195 mg g-1 (15 %). Für OctaBDE-Isomere in ABS ergab sich für srj = 0,029 mg g-1 (6,9 %) und sRj = 0,114 mg g-1 (27 %) und für OctaBDE-Isomere in PS srj = 0,043 mg g-1 (4,3 %) und sRj = 0,255 mg g-1 (26 %). KW - Pentabromdiphenylether (PentaBDE) KW - Octabromdiphenylehter (OctaBDE) KW - Polymer KW - Vergleichspräzision KW - Wiederholpräzision KW - Richtlinie 2003/11/EG KW - Richtlinie 76/769/EWG KW - GC/MS KW - Polybromierte Flammschutzmittel PY - 2005 SN - 1862-4804 SN - 0722-186X IS - 23 SP - 1 EP - 152 PB - Umweltbundesamt CY - Dessau-Roßlau AN - OPUS4-10848 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kemmlein, Sabine T1 - Entwicklung eines Standardanalyseverfahrens zur Bestimmung von penta-und octabromierten Diphenylethern (PBDE) in Polymeren T2 - Seminartour Shimadzu Deutschland CY - Berlin, Germany DA - 2005-06-21 PY - 2005 AN - OPUS4-7699 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Kemmlein, Sabine A1 - Bergmann, Meike A1 - Jann, Oliver T1 - Standard measurement method for the determination of polybrominated flame retardants (pentabromo diphenylether, octabromo diphenylether) in products (Research Report 202 67 300 / UBA-FB 000839/e) N2 - In accordance with the Directive 2003/11/EC amending the Council Directive 76/769/EEC for the 24th time, pentabromo and octabromo diphenylethers may not be used or put on the market in concentrations higher than 0.1 % by mass. To verify this threshold value a standard measurement method for the determination of selected pentabromo diphenylethers (pentaBDE-isomers) and octabromo diphenylethers (octaBDE-isomers) in polymers based on gas chromatography mass spectrometry (GC/MS) was developed. The following target compounds were selected for the investigations: BDE85 (2,2’,3,4,4’-pentaBDE), BDE99 (2,2’,4,4’,5- pentaBDE), BDE100 (2,2’,4,4’,6-pentaBDE), BDE203 (2,2’,3,4,4’,5,5’,6-octaBDE), BDE196 (2,2’,3,3’,4,4’,5,6’-octaBDE), BDE197 (2,2’,3,3’,4,4’,6,6’-OctaBDE). The following reference materials were prepared: polyurethane (PUR-H) and epoxy resin (EP) containing 0.1 % by mass of sum of pentaBDE isomers, polystyrene (PS) and acrylnitril-butadiene-styrenecopolymer (ABS) containing 0.1 % by weight of sum of octaBDE isomers. For quality assurance of the standard measurement method an interlaboratory comparison was conducted between 1 June and 30 November 2004 where 18 participants were involved. Data assessment was performed in accordance with DIN ISO 5725-2:2002-12 “Accuracy (trueness and precision) of measurement methods and results – Part 2: Basic methods for the determination of repeatability and reproducibility of a standard measurement method”. The following general mean values and standard deviations were obtained: 1.09 ± 0.16 mg g-1 (15 %) (sum pentaBDE isomers/EP), 1.3 ± 0.19 mg g-1 (15 %) (sum pentaBDE isomers/PUR-H), 0.99 ± 0.27 mg g-1 (27 %) (sum octaBDE isomers/PS), 0.42 ± 0.11 mg g-1 (26 %) (sum octaBDE isomers/ABS). The reproducibility standard deviation sRj and repeatability standard deviation srj were calculated as statistical parameters. The repeatability of the sum of pentaBDE isomers in EP was srj= 0.044 mg g-1 (4.0 %) and the reproducibility was sRj = 0.167 mg g-1 (15 %). srj and the sRj were 0.038 mg g-1 (2.9 %) and 0.195 mg g-1 (15 %), respectively, for the sum of pentaBDE isomers in PUR-H. For the sum of octaBDE isomers in ABS srj and sRj were determined to 0.029 mg g-1 (6.9 %) and 0.114 mg g-1 (27 %), respectively. For the sum of octaBDE isomers in PS the srj = 0.043 mg g-1 (4.3 %) and sRj = 0.255 mg g-1 (26 %) were obtained. KW - Pentabromo Diphenylether (pentaBDE) KW - Octabromo Diphenylether (octaBDE) KW - Polymer KW - Reproducibility KW - Repeatability KW - Directive 2003/11/EC KW - Directive 76/769/EEC KW - GC/MS KW - Polybrominated flame retardants PY - 2005 UR - http://www.umweltbundesamt.de/publikationen/standard-measurement-method-for-determination-of SN - 1862-4804 SN - 0722-186X IS - 31 SP - 1 EP - 151 PB - Umweltbundesamt CY - Dessau-Roßlau AN - OPUS4-12129 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kemmlein, Sabine T1 - Entwicklung eines Standardanalyseverfahrens zur Bestimmung von penta- und octabromierten Diphenyletheern (PBDE) in Polymeren T2 - Seminartour Shimadzu Deutschland CY - Duisburg, Germany DA - 2005-06-21 PY - 2005 AN - OPUS4-12261 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kemmlein, Sabine A1 - Bergmann, Meike A1 - Jann, Oliver T1 - Verfahren zur quantitativen Bestimmung von pentabromierten und octabromierten Diphenylethern in Polymeren KW - Pentabromdiphenylether (PentaBDE) KW - Octabromdiphenylether (OctaBDE) KW - Polymer KW - Richtlinie 2003/11/EG KW - Richtlinie 76/769/EWG KW - GC/MS PY - 2005 SN - 0340-7551 VL - 35 IS - 3 SP - 245 EP - 251 PB - Bundesanstalt für Materialprüfung CY - Berlin AN - OPUS4-10853 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Wilke, Olaf A1 - Kirchner, D. A1 - Jann, Oliver A1 - Kemmlein, S. A1 - Kalus, Sabine A1 - Süßmilch, C. T1 - European interlaboratory study for sampling VOC emissions - Step 1 - Liquid samples added on Tenax tubes T2 - Indoor Air 2008, 11th International Conference on Indoor Air Quality and Climate CY - Copenhagen, Denmark DA - 2008-08-17 KW - ISO 16000-6 KW - VOC analysis KW - Interlaboratory study KW - Emission tests KW - Building material PY - 2008 IS - Paper 226 SP - 1 AN - OPUS4-18048 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -