TY - JOUR A1 - Blankschän, M. A1 - Kanzler, D. A1 - Bertovic, Marija A1 - Rosenthal, Martina A1 - Liebich, R. T1 - Influence of illuminance on indication detectability during visual testing N2 - Visually detecting irregularities on components is a complex process, influenced by physical, technical, and human factors. Current standards mainly focus on illuminance, demanding highest accuracy for it, without providing scientific justification. In this research, 63 inspectors visually inspected forgings, with and without crack-like indications. The influence of illuminance on probability of detection was investigated. Therefore, illuminance was varied in three steps (200 lx, 350 lx, 500 lx). Human factors (e.g., experience, motivation) were recorded by using questionnaires. The results show no significant difference in probability of detection between the three illuminance levels. Equal probability of detection rates could be achieved at illuminances below and at the required threshold (500 lx). A difference in illuminance was found between the measurement point and the test area of the respective participant. This leads to higher assumed illuminance than present on the component. Compared with the measurement accuracy of the used illuminance meter, none of these deviations could be used to explain the similar results at different illuminance. The fact that illuminance has a significant influence in detecting indications has been disproven for this case. Whether human factors can provide explanation for the results remains unclear. This will be investigated in further research. KW - Illuminance KW - Non-destructive testing KW - Probability of detection KW - Reliability KW - Visual inspection PY - 2022 DO - https://doi.org/10.1515/mt-2022-0112 VL - 64 IS - 10 SP - 1532 EP - 1543 PB - De Gruyter AN - OPUS4-56019 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bertovic, Marija A1 - Given, Joseph A1 - Rentala, V K A1 - Wall, M A1 - Kanzler, D A1 - Lehleitner, Johannes A1 - Heckel, Thomas A1 - Tkachenko, Viktoriya T1 - Methods for quantification and integration of human factors into probability of detection assessments N2 - Human factors (HFs) are a frequently mentioned topic when talking about the reliability of non-destructive testing (NDT). However, probability of detection (POD), the commonly used measure of NDT reliability, only looks at the technical capability of an NDT system to detect a defect. After several decades of research on the influence of HFs on NDT reliability, there is still no commonly accepted approach to rendering HFs visible in reliability assessment. This paper provides an overview of possible quantitative and qualitative methods for integrating HFs into the reliability assessment. It is concluded that reliability assessment is best carried out using both quantifiable and non-quantifiable approaches to HFs. KW - Materials Chemistry KW - Metals and Alloys KW - Mechanical Engineering KW - Mechanics of Materials KW - Non-Destructive Testing (NDT) KW - Human factors KW - Detection Assessments PY - 2023 DO - https://doi.org/10.1784/insi.2023.65.7.364 SN - 1354-2575 VL - 65 IS - 7 SP - 364 EP - 372 PB - British Institute of Non-Destructive Testing (BINDT) AN - OPUS4-59173 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Mohsin, G. F. A1 - Schmitt, F.-J. A1 - Kanzler, C. A1 - Epping, J. D. A1 - Flemig, Sabine A1 - Hornemann, A. T1 - Structural characterization of melanoidin formed from D-glucose and L-alanine at different temperatures applying FTIR, NMR, EPR, and MALDI-ToF-MS N2 - The aim of this study was to identify specific chemical bonds and characteristic structures in melanoidins formed from D-glucose and L-alanine between 130 and 200 °C. The results might be used to control the type and amount of melanoidin produced during food processing. For this purpose, complementary techniques, such as FTIR, NMR, EPR, and MALDI-ToF, were employed. At 160 °C color, solubility and UV/Vis absorption change characteristically and consequently, structural transformations could be observed in FTIR and NMR spectra. For example, sharp signals of N-H, C-N, and C-H oscillations in the L-alanine spectrum are prone to inhomogeneous broadening in melanoidins prepared above 150 °C. These changes are caused due to formation of heterogeneous macromolecular structures and occur during condensation reactions that lead to an increasing loss of water from the melanoidins with increasing temperatures. Additionally, MALDI-ToF-MS indicates the polymerization of glyoxal/glyoxylic acid and EPR shows the formation of radical structures. KW - MALDI-ToF-MS KW - Melanoidine KW - Konjugate KW - Lebensmittel KW - MALDI-ToF-MS KW - L-alanine KW - D-glucose KW - Maillard reaction KW - FTIR spectroscopy KW - EPR spectroscopy KW - Melanoidin KW - NMR spectroscopy PY - 2018 DO - https://doi.org/10.1016/j.foodchem.2017.11.115 SN - 0308-8146 VL - 245 SP - 761 EP - 767 PB - Elsevier Science CY - Amsterdam, NL AN - OPUS4-44018 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kanzler, D. A1 - Müller, Christina T1 - How much information do we need? A reflection of the correct use of real defects in POD-evaluations N2 - To evaluate the capability of a non destructive testing system the “truth” of the used defects is essential. But what exactly is the truth of a real defect? And how much information is usable for the study? This presentation gives an overview about an advanced use of multiple metallographic cuts for the POD evaluation. In the presentation an approach is shown where information of metallographic studies are reconstructed and weighted to gain the essential information about real defects and which information are important for the detection with radiographic testing equipment. Furthermore, different connection points are discussed were additional knowledge from simulation and artificial defects can be used to gain additional certainty for the result of the evaluation. The methodology is used for the evaluation for the digital radiographic testing system for the testing of electron-beam welds, which is one possible choice to seal the Finnish copper canisters for the final deposit of spent nuclear fuel. T2 - 42nd annual review of progress in quantitative nondestructive evaluation: Incorporating the 6th European-American Workshop on Reliability of NDE CY - Minneapolis, MN, USA DA - 25.07.2015 KW - NDT KW - POD KW - Radiography PY - 2016 DO - https://doi.org/10.1063/1.4940652 SN - 0094-243X VL - 1706 SP - 200008-1 EP - 200008-7 PB - AIP Publishing AN - OPUS4-37596 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -