TY - JOUR A1 - Schmidt, C. A1 - Hensen, C. A1 - Wallmann, K. A1 - Liebetrau, V. A1 - Tatzel, Michael A1 - Schurr, S. L. A1 - Kutterolf, S. A1 - Haffert, L. A1 - Geilert, Sonja A1 - Hübscher, C. A1 - Lebas, E. A1 - Heuser, A. A1 - Schmidt, M. A1 - Strauss, H. A1 - Vogl, Jochen A1 - Hansteen, T. T1 - Origin of High Mg and SO4 Fluids in Sediments of the Terceira Rift, Azores‐Indications for Caminite Dissolution in a Waning Hydrothermal System N2 - During R/V Meteor cruise 141/1, pore fluids of near surface sediments were investigated to find indications for hydrothermal activity in the Terceira Rift (TR), a hyperslow spreading center in the Central North Atlantic Ocean. To date, submarine hydrothermal fluid venting in the TR has only been reported for the D. João de Castro seamount, which presently seems to be inactive. Pore fluids sampled close to a volcanic cone at 2,800‐m water depth show an anomalous composition with Mg, SO4, and total alkalinity concentrations significantly higher than seawater and a nearby reference core. The most straightforward way of interpreting these deviations is the dissolution of the hydrothermally formed mineral caminite (MgSO4 0.25 Mg (OH)2 0.2H2O). This interpretation is corroborated by a thorough investigation of fluid isotope systems (δ26Mg, δ30Si, δ34S, δ44/42Ca, and 87Sr/86Sr). Caminite is known from mineral assemblages with anhydrite and forms in hydrothermal recharge zones only under specific conditions such as high fluid temperatures and in altered oceanic crust, which are conditions generally met at the TR. We hypothesize that caminite was formed during hydrothermal activity and is now dissolving during the waning state of the hydrothermal system, so that caminite mineralization is shifted out of its stability zone. Ongoing fluid circulation through the basement is transporting the geochemical signal via slow advection toward the seafloor. KW - Isotope ratio KW - Delta value KW - Pore fluids KW - Magnesium KW - Hydrothermal fluid PY - 2019 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-503430 DO - https://doi.org/10.1029/2019GC008525 VL - 20 IS - 12 SP - 6078 EP - 6094 PB - Wiley AN - OPUS4-50343 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Göbel, E. O. A1 - Hasche, K. A1 - Ulm, G. A1 - Krumrey, M. A1 - Ade, G. A1 - Stümpel, J. A1 - Herrmann, K. A1 - Koenders, L. A1 - Thomsen-Schmidt, P. A1 - Pohlenz, F. A1 - Xu, M. A1 - Dai, G. A1 - Hoffmann, K.-P. A1 - Busch, I. A1 - Frank, W. A1 - Procop, M. A1 - Beck, Uwe T1 - Kalibrierte Schichtdicken-Maßverkörperungen für Nanometerschichten, Teilvorhaben - Kalibrierung von Schichtdicken-Maßverkörperungen im Nanometerbereich - Abschlussbericht des BMBF Verbundvorhabens 13N7704 - 13N77041 KW - Schichtdicke KW - Nanometerbereich PY - 2003 UR - http://edok01.tib.uni-hannover.de/edoks/e01fb02/373214030.pdf SP - 1 EP - 131 PB - Physikalisch-Technische Bundesanstalt CY - Dresden AN - OPUS4-25428 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bachmann, H. J. A1 - Bucheli, T. D. A1 - Dieguez-Alonso, A. A1 - Fabbri, D. A1 - Knicker, H. A1 - Schmidt, H.-P. A1 - Ulbricht, A. A1 - Becker, Roland A1 - Buscaroli, A. A1 - Buerge, D. A1 - Cross, A. A1 - Dickinson, D. A1 - Enders, A. A1 - Esteves, V.I. A1 - Evangelou, M. W. H. A1 - Fellet, G. A1 - Friedrich, K. A1 - Gasco Guerrero, G. A1 - Glaser, B. A1 - Hanke, U. M. A1 - Hanley, K. A1 - Hilber, I. A1 - Kalderis, D. A1 - Leifeld, J. A1 - Masek, O. A1 - Mumme, J. A1 - Paneque Carmona, M. A1 - Calvelo Pereira, R. A1 - Rees, F. A1 - Rombola, A. G. A1 - de la Rosa, J. M. A1 - Sakrabani, R. A1 - Sohi, S. A1 - Soja, G. A1 - Valagussa, M. A1 - Verheijen, F. A1 - Zehetner, F. T1 - Towards the standardization of biochar analysis: the COST action TD1107 interlaboratory comparison N2 - Biochar produced by pyrolysis of organic residues is increasingly used for soil amendment and many other applications. However, analytical methods for its physical and chemical characterization are yet far from being specifically adapted, optimized, and standardized. Therefore, COST Action TD1107 conducted an interlaboratory comparison in which 22 laboratories from 12 countries analyzed three different types of biochar for 38 physical–chemical parameters (macro- and microelements, heavy metals, polycyclic aromatic hydrocarbons, pH, electrical conductivity, and specific surface area) with their preferential methods. The data were evaluated in detail using professional interlaboratory testing software. Whereas intralaboratory repeatability was generally good or at least acceptable, interlaboratory reproducibility was mostly not (20% < mean reproducibility standard deviation < 460%). This paper contributes to better comparability of biochar data published already and provides recommendations to improve and harmonize specific methods for biochar analysis in the future. KW - Biochar KW - Analysis KW - Standardization KW - Ring test KW - Interlaboratory comparison PY - 2016 DO - https://doi.org/10.1021/acs.jafc.5b05055 SN - 0021-8561 SN - 1520-5118 VL - 64 IS - 2 SP - 513 EP - 527 PB - American Chemical Society CY - Columbus, Ohio AN - OPUS4-35289 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Jablonka, Kevin Maik A1 - Ai, Qianxiang A1 - Al-Feghali, Alexander A1 - Badhwar, Shruti A1 - Bocarsly, Joshua D. A1 - Bran, Andres M. A1 - Bringuier, Stefan A1 - Brinson, L. Catherine A1 - Choudhary, Kamal A1 - Circi, Defne A1 - Cox, Sam A1 - de Jong, Wibe A. A1 - Evans, Matthew L. A1 - Gastellu, Nicolas A1 - Genzling, Jerome A1 - Gil, María Victoria A1 - Gupta, Ankur K. A1 - Hong, Zhi A1 - Imran, Alishba A1 - Kruschwitz, Sabine A1 - Labarre, Anne A1 - Lála, Jakub A1 - Liu, Tao A1 - Ma, Steven A1 - Majumdar, Sauradeep A1 - Merz, Garrett W. A1 - Moitessier, Nicolas A1 - Moubarak, Elias A1 - Mouriño, Beatriz A1 - Pelkie, Brenden A1 - Pieler, Michael A1 - Ramos, Mayk Caldas A1 - Ranković, Bojana A1 - Rodriques, Samuel G. A1 - Sanders, Jacob N. A1 - Schwaller, Philippe A1 - Schwarting, Marcus A1 - Shi, Jiale A1 - Smit, Berend A1 - Smith, Ben E. A1 - Van Herck, Joren A1 - Völker, Christoph A1 - Ward, Logan A1 - Warren, Sean A1 - Weiser, Benjamin A1 - Zhang, Sylvester A1 - Zhang, Xiaoqi A1 - Zia, Ghezal Ahmad Jan A1 - Scourtas, Aristana A1 - Schmidt, K. J. A1 - Foster, Ian A1 - White, Andrew D. A1 - Blaiszik, Ben T1 - 14 examples of how LLMs can transform materials science and chemistry: a reflection on a large language model hackathon N2 - Large-language models (LLMs) such as GPT-4 caught the interest of many scientists. Recent studies suggested that these models could be useful in chemistry and materials science. To explore these possibilities, we organized a hackathon. This article chronicles the projects built as part of this hackathon. Participants employed LLMs for various applications, including predicting properties of molecules and materials, designing novel interfaces for tools, extracting knowledge from unstructured data, and developing new educational applications. The diverse topics and the fact that working prototypes could be generated in less than two days highlight that LLMs will profoundly impact the future of our fields. The rich collection of ideas and projects also indicates that the applications of LLMs are not limited to materials science and chemistry but offer potential benefits to a wide range of scientific disciplines. KW - Large Language model KW - Hackathon KW - Concrete KW - Prediction KW - Inverse Design KW - Orchestration PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-589961 DO - https://doi.org/10.1039/d3dd00113j VL - 2 IS - 5 SP - 1233 EP - 1250 PB - Royal Society of Chemistry (RSC) AN - OPUS4-58996 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Frost, K. A1 - Lüth, Peter A1 - Schmidt, Martin A1 - Simon, K. A1 - Uhlig, St. T1 - Evaluation of the interlaboratory test 2015-2016 on the method DIN EN 15188:2007 "Determination of the spontaneous ignition behaviour of dust accumulations" N2 - For the classification, safe handling and use of the chemicals, special standardized testing procedures have been developed and are used worldwide. Safety experts must be able to fully rely on the precise execution of the respective laboratory tests and assessments. In this context, interlaboratory tests are a crucial element of a laboratory's quality system. Participation in interlaboratory tests is explicitly recommended by the standard ISO/IEC 17025. The present document reports the results of the interlaboratory test 2015-2016, which was performed on the test method DIN EN 15188:2007 “Determination of the spontaneous ignition behaviour of dust accumulations”. It was organized by BAM in the frame of the co-operation project CEQAT-DGHS Centre for Quality Assurance for Testing of Dangerous Goods and Hazardous Substances. The test method DIN EN 15188:2007 is applied to characterize the self-ignition behaviour of combustible dusts. The experimental basis for describing the self-ignition behaviour of a given dust is the determination of the self-ignition temperatures (TSI) of differently-sized volumes of the dust sample by isoperibolic hot storage experiments (storage at constant oven temperatures) in commercially available ovens. The results measured this way reflect the dependence of the self-ignition temperatures on the volume of a dust accumulation. The interlaboratory test 2015-2016 on the method DIN EN 15188:2007 is the latest in a systematic stepwise built up series of method validation interlaboratory tests and internal laboratory investigations. The aim of this interlaboratory test was to determine measurement uncertainties of the modified method DIN EN 15188 for different substances, covering a sufficiently wide range of self-ignition behaviours in the scope of the DIN EN 15188 of the four basket test to extrapolate to storage volumes up to 1000 m³ and the single basket test for a basket volume of 1000 cm³. The precision of the four basket test and the single basket of the modified method DIN EN 15188 can be assessed as acceptable for the four sample materials investigated in the current interlaboratory test 2015-2016. It was possible to derive a functional equation for the measurement uncertainty U depending on the storage volume V. The measurement uncertainty cannot be ignored and must be considered, if TSI results should be used in practice. KW - Gefahrgut KW - Gefahrstoff KW - Ringversuch KW - Prüfmethode KW - Validierung KW - Qualitätssicherung KW - Messunsicherheit KW - Dangerous goods KW - Hazardous substances KW - Round robin test KW - Interlaboratory comparison KW - Test method KW - Validation KW - Measurement uncertainty PY - 2016 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-387343 SN - 978-3-9818270-0-2 SP - 1 EP - 106 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-38734 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Thomsen-Schmidt, P. A1 - Hasche, K. A1 - Ulm, G. A1 - Herrmann, K. A1 - Krumrey, M. A1 - Ade, G. A1 - Stümpel, J. A1 - Busch, I. A1 - Schädlich, S. A1 - Schindler, A. A1 - Frank, W. A1 - Hirsch, D. A1 - Procop, Mathias A1 - Beck, Uwe T1 - Realisation and metrological characterisation of thickness standards below 100 nm N2 - High-accuracy film thickness measurements in the range below 100 nm can be made by various complex methods like spectral ellipsometry (SE), scanning force microscopy (SFM), grazing incidence X-ray reflectometry (GIXR), or X-ray fluorescence analysis (XRF). The measurement results achieved with these methods are based on different interactions between the film and the probe. A key question in nanotechnology is how to achieve consistent results on a level of uncertainty below one nanometre with different techniques. Two different types of thickness standards are realised. Metal film standards for X-ray techniques in the thickness range 10 to 50 nm are calibrated by GIXR with monochromatised synchrotron radiation of 8048 eV. The results obtained at four different facilities show excellent agreement. SiO2 on Si standards for SE and SFM in the thickness range 6 to 1000 nm are calibrated by GIXR with monochromatised synchrotron radiation of 1841 eV and with a metrological SFM. Consistent results within the combined uncertainties are obtained with the two methods. Surfaces and interfaces of both types of standards are additionally investigated by transmission electron microscopy (TEM). PY - 2004 DO - https://doi.org/10.1007/s00339-003-2273-7 SN - 0947-8396 VL - 78 IS - 5 SP - 645 EP - 649 PB - Springer CY - Berlin AN - OPUS4-17195 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Hasche, K. A1 - Ulm, G. A1 - Herrmann, K. A1 - Krumrey, M. A1 - Ade, G. A1 - Sümpel, J. A1 - Busch, I. A1 - Thomsen-Schmidt, P. A1 - Schädlich, S. A1 - Schindler, A. A1 - Frank, W. A1 - Procop, Mathias A1 - Beck, Uwe T1 - About the calibration of thickness standards on the nanometer scale T2 - 3rd International EUSPEN conference ; 3rd International conference. European Society for Precision Engineering and Nanotechnology ; 4th General meeting. European Society for Precision Engineering and Nanotechnology CY - Eindhoven, The Netherlands DA - 2002-05-26 PY - 2002 SN - 90-386-2883-8 SP - 1 EP - 5 CY - Eindhoven AN - OPUS4-2283 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hasche, K. A1 - Herrmann, K. A1 - Thomsen-Schmidt, P. A1 - Krumrey, M. A1 - Ulm, G. A1 - Ade, G. A1 - Pohlenz, F. A1 - Stümpel, J. A1 - Busch, I. A1 - Schädlich, S. A1 - Frank, W. A1 - Hirsch, D. A1 - Schindler, A. A1 - Procop, Mathias A1 - Beck, Uwe T1 - Ein Beitrag zu kalibrierten Nanometerschichten für unterschiedliche Anwendungsbereiche N2 - Nanotechnologien werden gegenwärtig als leistungsfähige Oberflächentechniken in erheblichem Umfange industriell genutzt. Dabei spielen dünne Schichten und deren Kenndaten eine wesentliche Rolle, z.B. als Röntgenspiegel oder optische und magnetooptische Datenträger. Die Schichtdicke zählt hierbei zu den technologisch wichtigen Parametern. Abgeleitet von Anwenderinteressen, werden für die Röntgenreflektometrie (XRR bzw. GIXR), Elektronenstrahl-Mikroanalyse (EPMA) und Röntgenfluoreszenzanalyse (XRF) einerseits und die Ellipsometrie andererseits zugeschnittene Schichtdickenmaßverkörperungen (SDM) entwickelt, gefertigt und untersucht. Das Ziel ist die Bereitstellung praxistauglicher, kalibrierter SDM, im weiteren Schichtdickennormale (SDN) genannt. SDN sind Maßverkörperungen, für die der Schichtdickenwert mit einer definierten Messunsicherheit bekannt und auf ein metrologisch anerkanntes Längennormal zurückgeführt ist. Berichtet wird über die Herstellung und messtechnische Charakterisierung der beiden spezifischen Varianten von Maßverkörperungen. T2 - 47. Internationales Wissenschaftliches Kolloquium. Technische Universität Ilmenau ; Herbstkonferenz der Gesellschaft für Arbeitswissenschaft ; 6. Workshop Multimedia für Bildung und Wirtschaft CY - Ilmenau, Deutschland DA - 2002-09-23 PY - 2002 UR - http://publica.fraunhofer.de/documents/N-14872.html VL - 47 SP - 568 EP - 569 PB - Techn. Univ. CY - Ilmenau AN - OPUS4-2284 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Kunath, K. A1 - Lüth, Peter A1 - Schmidt, Martin A1 - Simon, K. A1 - Uhlig, S. T1 - Evaluation of the interlaboratory test 2010-2011 on the method DIN EN15188:2007 'Determination of the spontaneous ignition behaviour of dust accumulations' N2 - For the classification and safe handling and use of the chemicals, special standardized testing proce-dures have been developed and are used world-wide. Safety experts must be able to fully rely on the precise execution of the respective laboratory tests and assessments. In this context interlaboratory tests (round robin tests, interlaboratory comparisons / intercomparisons) are a crucial element of a laboratory's quality system. Participation in interlaboratory tests is explicitly recommended by the standard ISO/IEC 17025. The present document reports on the results of the interlaboratory test 2010/2011 on the test method DIN EN 15188:2007 “Determination of the spontaneous ignition behaviour of dust accumulations” [1] which was organized by the Center for Quality Assurance for Testing of Dangerous Goods and Haz-ardous Substances. The test method DIN EN 15188:2007 is applied to characterize the self-ignition behaviour of combus-tible dusts. The experimental basis for describing the self-ignition behaviour of a given dust is the de-termination of the self-ignition temperatures (TSI) of differently-sized volumes of the dust sample by isoperibolic hot storage experiments (storage at constant oven temperatures) in commercially availa-ble ovens. The results thus measured reflect the dependence of self-ignition temperatures upon dust volume [1]. Several internal investigations and interlaboratory comparisons in the past have shown significant differences between the lab-specific results of hot storage tests. Figure 2-1 shows the Pseudo-Arrhenius plot of hot storage tests of eight different laboratories (Round Robin Test 2002, BAM). The dust under this investigation was Lycopodium powder (spores). The par-ticipants of this interlaboratory test used different laboratory ovens (size, ventilation) as well as differ-ent sample baskets (shape, mesh size, single- and double-walled). Figure 2-1 shows clearly that this test failed to produce reasonable reproducibility of the TSI between the different laboratories. As possible reasons for the deviations have been identified lab-specific dif-ferences, e.g.: - oven ventilation (enforced, natural convection), - oven size, - sample baskets, - radiation effects, - measuring precision (temperature difference between tests with ignition and no ignition), - minimum sample size. To reduce the differences between the labs it was necessary to ameliorate the testing method and to improve the execution of the method by the lab. From there, the installation of an inner chamber into the laboratory oven was suggested as experimental set-up in EN 15188:2007 to provide more repro-ducible test conditions. The aappropriateness of this set-up has not been verified yet. The current interlaboratory test 2010-2011 focuses on the use of a special mesh wire screen and spe-cial volumes of the sample baskets (cubes) to normalise/harmonise the test conditions in the different labs. In preparation for the interlaboratory test a joint program between Syngenta and BAM has been initiated in 2009. As a result of these investigations a modified set-up ( chapter 3) has been identi-fied to be probably more appropriate than the suggested set-up in DIN EN-15188:2007. Due to the time-consuming test procedure and to optimize the workflow for the laboratories this in-terlaboratory test should be performed stepwise as a multi-level test ( chapter 5.4) on one typical test sample. KW - Interlaboratory test KW - Self-ignition KW - Spontaneous ignition PY - 2013 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-282978 SN - 978-3-9815748-4-5 IS - Final Report SP - 1 EP - 113 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-28297 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Thomsen-Schmidt, P. A1 - Hasche, K. A1 - Ulm, G. A1 - Herrmann, K. A1 - Krumrey, M. A1 - Ade, G. A1 - Stümpel, J. A1 - Procop, Mathias A1 - Beck, Uwe T1 - Realisation and metrological characterisation of thickness standards below 100 nm T2 - DVG Jahrestagung 2002 CY - Magdeburg, Germany DA - 2002-06-17 PY - 2002 SP - 1 EP - 9 PB - Deutsche Vakuum-Gesellschaft CY - Kaiserslautern AN - OPUS4-1936 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Frost, K. A1 - Lüth, Peter A1 - Schmidt, Martin A1 - Simon, K. A1 - Uhlig, S. T1 - Interlaboratory test 2023 on the method DIN EN 15188:2021-07 "Determination of the spontaneous ignition behaviour of dust accumulations" - Final report of results N2 - The test method DIN EN 15188:2021-07 “Determination of the spontaneous ignition behaviour of dust accumulations” is applied to characterize the self-ignition behaviour of combustible dusts. The experimental basis for describing the self-ignition behaviour of a given dust is the determination of the self-ignition temperatures (TSI) of differently-sized volumes of the dust sample by isoperibolic hot storage experiments (storage at constant oven temperatures) in commercially available ovens. The results measured this way reflect the dependence of the self-ignition temperatures on the volume of a dust accumulation. Several internal investigations in the past (e.g. interlaboratory tests in 2010-2011 and 2015-2016) have shown significant differences between the lab-specific results of hot storage tests of the former version of the revised DIN EN 15188:2021-07 (DIN EN 15188:2007). Therefore, an improvement of the test method DIN EN 15188:2007 was necessary. After a rather long and extensive series of various improvements (methodological modifications), the interlaboratory test in 2015-2016 demonstrated an acceptable reliability of the test method and a satisfactory measurement uncertainty if the modifications described in the interlaboratory test are taken into account. On the basis of this interlaboratory test in 2015, this subsequently led to a revision of the standard, whereby, in addition to the methodological improvements, the measurement uncertainty to be taken into account could now also be specified for the first time in this standard. The revised DIN EN 15188:2021-07 was published in 2021 and can now be applied by laboratories. This report provides the laboratory results of the first interlaboratory test 2023 on the revised method DIN EN 15188:2021-07 and summarizes the results of the assessment of laboratory performance. KW - DIN EN 15188:2021-07 KW - Spontaneous ignition KW - Interlaboratory test KW - Round robin test KW - Proficiency test KW - Dangerous goods KW - Hazardous substances KW - Measurement uncertainty KW - Gefahrgut KW - Gefahrstoff KW - Qualitätssicherung KW - Ringversuch KW - Selbstentzündung KW - Staub KW - Dust PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-614560 SN - 978-3-9818564-6-0 DO - https://doi.org/10.26272/opus4-61456 SP - 1 EP - 51 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin ET - 1. AN - OPUS4-61456 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -