TY - CONF A1 - Deresch, Andreas A1 - Jaenisch, Gerd-Rüdiger A1 - Bellon, Carsten A1 - Warrikhoff, A. ED - Thompson, D.O. ED - Chimenti, D.E. T1 - Simulation and experimental verification of X-ray spectra T2 - 36th Annual Review of Progress in Quantitative Nondestructive Evaluation CY - Kingston, RI, USA DA - 2009-07-26 KW - X-ray KW - Spectrum KW - Simulation KW - Röntgenspektrum KW - Dekonvolution PY - 2010 SN - 978-0-7354-0748-0 SN - 0743-0760 SN - 0094-243X N1 - Serientitel: AIP conference proceedings – Series title: AIP conference proceedings VL - 1211 SP - 535 EP - 540 CY - Melville, NY AN - OPUS4-21136 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Zhukovskiy, M. A1 - Skachkov, M. A1 - Jaenisch, Gerd-Rüdiger A1 - Bellon, Carsten A1 - Deresch, Andreas T1 - Monte Carlo simulating the electron emission from surfaces of objects being under radiation T2 - 10th European conference on non-destructive testing CY - Moscow, Russia DA - 2010-06-07 KW - Simulation KW - Elektronentransport PY - 2010 IS - Paper 4.02.18 SP - 1 EP - 10 AN - OPUS4-22764 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Deresch, Andreas A1 - Jaenisch, Gerd-Rüdiger A1 - Bellon, Carsten A1 - Warrikhoff, A. T1 - Optimization of X-ray sources by modeling T2 - 10th European conference on non-destructive testing CY - Moscow, Russia DA - 2010-06-07 KW - Simulation KW - Elektronentransport KW - Röntgenquellen PY - 2010 IS - Paper 4.02.18 SP - 1 EP - 10 AN - OPUS4-22766 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Jaenisch, Gerd-Rüdiger A1 - Bellon, Carsten A1 - Ewert, Uwe T1 - Simulation supported reliability analysis in radiography T2 - 10th European conference on non-destructive testing CY - Moscow, Russia DA - 2010-06-07 KW - Simulation KW - Zuverlässigkeit KW - POD PY - 2010 IS - Paper 4.02.18 SP - 1 EP - 13 AN - OPUS4-22767 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Jaenisch, Gerd-Rüdiger T1 - Scatter Ratio at High Energies - Simulation and Experiments T2 - BINDT - NDT 2010 CY - Cardiff, Wales DA - 2010-09-14 PY - 2010 AN - OPUS4-22787 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Jaenisch, Gerd-Rüdiger A1 - Deresch, Andreas A1 - Bellon, Carsten A1 - Ewert, Uwe A1 - Przybilla, Waldemar ED - Thompson, D.O. ED - Chimenti, D.E. T1 - Measurement and modeling of scatter ratios at high energies N2 - Determining scatter ratios at high energies (> ~ 1MeV) presents challenges not immediately obvious from measurements at conventional X-ray energies. This includes reduced attenuation even in heavy elements as well as a stronger forward bias of scattering. In order to check the reliability of different measurement setups with regard to material thicknesses, distances, and collimation, attenuation and scattering were separately simulated using a Monte Carlo model. The simulation results help in understanding the sources of radiation scattered into the detection area, thereby aiding in eliminating undesired contributions. T2 - 37th Annual Review of Progress in Quantitative Nondestructive Evaluation CY - San Diego, CA, USA DA - 18.07.2010 KW - Radiography KW - Optimisation KW - X-ray detection KW - Simulation KW - High energy KW - Co-60 KW - Modeling KW - Scatter PY - 2011 SN - 978-0-7354-0888-3 DO - https://doi.org/10.1063/1.3591895 SN - 0743-0760 SN - 0094-243X N1 - Serientitel: AIP conference proceedings – Series title: AIP conference proceedings IS - 1335 SP - 517 EP - 524 PB - American Institute of Physics CY - Melville, NY AN - OPUS4-25358 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Jaenisch, Gerd-Rüdiger A1 - Ewert, Uwe T1 - Measurement and modeling of scatter ratios at high energies T2 - QNDE 2010 CY - San Diego, CA, USA DA - 2010-07-18 PY - 2010 AN - OPUS4-25383 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bellon, Carsten A1 - Deresch, Andreas A1 - Gollwitzer, Christian A1 - Jaenisch, Gerd-Rüdiger T1 - Radiographic simulator aRTist: version 2 N2 - Computer simulation of radiography can be used for different purposes in NDT, such as qualification of NDT systems, optimization of radiographic parameters, feasibility analysis, model-based data interpretation, and training of NDT/NDE personnel. BAM has been working on modeling in the field of radiographic testing for many years. With the gathered theoretical background and the familiarity with practical requirements of industrial application the simulation software aRTist has been developed. This analytical simulator includes a description of the radiation source, the interaction of radiation with test pieces and flaws, and the detection process with special focus on film and digital industrial radiology. It features high processing speed with nearinteractive frame rates and a high level of realism. Here we focus on the recent developments of the simulator, notably the release of aRTist version 2. Extended functionality regarding automated virtual computed tomography now allows for arbitrary scan paths. Another program extension supports reliability investigations and provides a user interface for planning automatic simulations with varying parameters and defects. T2 - 18th WCNDT - World conference on nondestructive testing CY - Durban, South Africa DA - 16.04.2012 KW - X-ray imaging KW - Radiographic testing KW - Simulation KW - Computed tomography PY - 2012 SN - 978-0-620-52872-6 SP - 1 EP - 7 (Paper 333) AN - OPUS4-27398 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Deresch, Andreas A1 - Jaenisch, Gerd-Rüdiger A1 - Bellon, Carsten A1 - Warrikhoff, A. T1 - Simulating X-ray spectra: from tube parameters to detector output N2 - A model is discussed which describes the generation of X-rays in conventional tubes using tabulated bremsstrahlung energy spectra depending on three variables: the target atomic number, the incident electron kinetic energy, and the fraction of energy radiated. Additionally a parameter-free description of the characteristic radiation is included. The constructed model includes technical tube parameters like kilovoltage, target material, and angles of electron incidence and photon emission to also account for self-absorption in the target, as well as radiographic parameters like filtering. In order to verify model results, detector response is also considered. The validity of the proposed model is shown by measurements. Future work includes the extension of the model to transmission targets. This research was supported by the German Federal Ministry of Economics and Technology under contract MNPQ transfer II D 5-30/06. T2 - 18th WCNDT - World conference on nondestructive testing CY - Durban, South Africa DA - 2012-04-16 KW - X-ray KW - Spectrum KW - Simulation PY - 2012 SN - 978-0-620-52872-6 SP - 1 EP - 8 (Paper 336) AN - OPUS4-27399 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gollwitzer, Christian A1 - Bellon, Carsten A1 - Deresch, Andreas A1 - Jaenisch, Gerd-Rüdiger A1 - Baron, H.-U. A1 - Ewert, Uwe T1 - Reliability investigations of radiographic testing using aRTist as a simulation tool N2 - Within the framework of the European project PICASSO, the radiographic simulator aRTist (analytical Radiographic Testing inspection simulation tool) developed by BAM has been extended for reliability assessment of film and digital radiography. A simulation supported probability of detection (POD) methodology has been developed and the validity of the approach has been studied using an application from the aeronautics industry. An experimental POD has been determined with the help of a specialized software tool, developed to aid with the collection of large series of POD data. The resulting POD is compared to simulations of the same setting using aRTist and the newly available module for simulation supported POD. A quantitative agreement within a few percent is achieved between the experimental and the simulation supported POD. T2 - 18th WCNDT - World conference on nondestructive testing CY - Durban, South Africa DA - 2012-04-16 KW - X-ray imaging KW - Probability of detection KW - Simulation PY - 2012 SN - 978-0-620-52872-6 SP - 1 EP - 10 (Paper 338) AN - OPUS4-27400 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Jaenisch, Gerd-Rüdiger A1 - Deresch, Andreas A1 - Bellon, Carsten A1 - Schumm, A. A1 - Guerin, P. ED - Chimenti, D.E. ED - Bond, L.J. ED - Thompson, D.O. T1 - A proposed benchmark for simulation in radiographic testing N2 - The purpose of this benchmark study is to compare simulation results predicted by various models of radiographic testing, in particular those that are capable of separately predicting primary and scatter radiation for specimens of arbitrary geometry. T2 - 40th Annual review of progress in quantitative nondestructive evaluation CY - Baltimore, Maryland, USA DA - 21.07.2013 KW - Benchmark KW - Simulation KW - Radiographic testing PY - 2014 SN - 978-0-7354-1212-5 SN - 978-0-7354-1211-8 DO - https://doi.org/10.1063/1.4865082 SN - 0094-243X N1 - Serientitel: AIP conference proceedings – Series title: AIP conference proceedings VL - 1581 SP - 2101 EP - 2106 PB - AIP Publishing AN - OPUS4-30756 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -